Initial commit
This commit is contained in:
327
MIBS/awplus/AT-FIBER-MONITORING-MIB
Normal file
327
MIBS/awplus/AT-FIBER-MONITORING-MIB
Normal file
@ -0,0 +1,327 @@
|
||||
-- ============================================================================
|
||||
-- AT-FIBER-MONITORING-MIB, Allied Telesis enterprise MIB:
|
||||
-- Fiber Monitoring MIB objects.
|
||||
--
|
||||
-- Copyright (c) 2015 by Allied Telesis, Inc.
|
||||
-- All rights reserved.
|
||||
--
|
||||
-- ============================================================================
|
||||
|
||||
AT-FIBER-MONITORING-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
sysinfo
|
||||
FROM AT-SYSINFO-MIB
|
||||
Integer32, Unsigned32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
|
||||
FROM SNMPv2-SMI
|
||||
DisplayString
|
||||
FROM SNMPv2-TC;
|
||||
|
||||
atFiberMon MODULE-IDENTITY
|
||||
LAST-UPDATED "201509080000Z"
|
||||
ORGANIZATION
|
||||
"Allied Telesis, Inc"
|
||||
CONTACT-INFO
|
||||
"http://www.alliedtelesis.com"
|
||||
DESCRIPTION
|
||||
"This MIB contains managed objects definition and notification
|
||||
definitions for AT Fiber Monitoring feature."
|
||||
REVISION "201509080000Z"
|
||||
DESCRIPTION
|
||||
"Initial revision"
|
||||
::= { sysinfo 27 }
|
||||
|
||||
--
|
||||
-- Textual conventions
|
||||
--
|
||||
|
||||
|
||||
--
|
||||
-- Node definitions
|
||||
--
|
||||
-- ---------------------------------------------------------- --
|
||||
-- Fiber Monitoring Notifications
|
||||
-- ---------------------------------------------------------- --
|
||||
atFiberMonNotifications OBJECT IDENTIFIER::= { atFiberMon 0 }
|
||||
|
||||
atFiberMonAlarmSetNotify NOTIFICATION-TYPE
|
||||
OBJECTS { atFiberMonIfindex, atFiberMonChannel, atFiberMonIfname, atFiberMonReading,
|
||||
atFiberMonThreshold }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A notification generated when the monitored received optical power of an SFP
|
||||
goes outside its alarm threshold."
|
||||
::= { atFiberMonNotifications 1 }
|
||||
|
||||
atFiberMonAlarmClearedNotify NOTIFICATION-TYPE
|
||||
OBJECTS { atFiberMonIfindex, atFiberMonChannel, atFiberMonIfname, atFiberMonReading,
|
||||
atFiberMonThreshold }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A notification generated when the monitored received optical power of an SFP
|
||||
returns to an acceptable value. This can occur because the power has returned
|
||||
to its previous level or the comparison baseline has adjusted to the new level."
|
||||
::= { atFiberMonNotifications 2 }
|
||||
|
||||
-- ---------------------------------------------------------- --
|
||||
-- Notification variables
|
||||
-- ---------------------------------------------------------- --
|
||||
atFiberMonTrapVariable OBJECT IDENTIFIER::= { atFiberMon 1 }
|
||||
|
||||
atFiberMonReading OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..65535)
|
||||
MAX-ACCESS accessible-for-notify
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The current received optical power reading for the port specified
|
||||
in the trap (x0.0001mW)"
|
||||
::= { atFiberMonTrapVariable 1 }
|
||||
|
||||
-- ---------------------------------------------------------- --
|
||||
-- Fiber monitoring configuration objects
|
||||
-- ---------------------------------------------------------- --
|
||||
atFiberMonConfigTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AtFiberMonConfigEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"It contains the objects used to configure the operation of fiber monitoring."
|
||||
::= { atFiberMon 2 }
|
||||
|
||||
atFiberMonConfigEntry OBJECT-TYPE
|
||||
SYNTAX AtFiberMonConfigEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Entry for the table. It contains the configurables of fiber monitering for an interface."
|
||||
INDEX { atFiberMonIfname }
|
||||
::= { atFiberMonConfigTable 1 }
|
||||
|
||||
|
||||
AtFiberMonConfigEntry ::=
|
||||
SEQUENCE {
|
||||
atFiberMonIfname
|
||||
OCTET STRING,
|
||||
atFiberMonEnable
|
||||
INTEGER,
|
||||
atFiberMonInterval
|
||||
Integer32,
|
||||
atFiberMonSensitivity
|
||||
OCTET STRING,
|
||||
atFiberMonBaseline
|
||||
OCTET STRING,
|
||||
atFiberMonAlarmAction
|
||||
INTEGER
|
||||
}
|
||||
|
||||
atFiberMonIfname OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (1..16))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The name of the interface where the pluggable is in."
|
||||
::= { atFiberMonConfigEntry 1 }
|
||||
|
||||
atFiberMonEnable OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
enabled(1),
|
||||
disabled(2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enable or disable fiber monitoring."
|
||||
::= { atFiberMonConfigEntry 2 }
|
||||
|
||||
atFiberMonInterval OBJECT-TYPE
|
||||
SYNTAX Integer32 (2..60)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Fiber monitoring polling interval in seconds."
|
||||
::= { atFiberMonConfigEntry 3 }
|
||||
|
||||
atFiberMonSensitivity OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The sensitivity for fiber monitoring.
|
||||
|
||||
Acceptable mode strings and value ranges are as below:
|
||||
|
||||
low - 2dB
|
||||
medium - 1dB
|
||||
high - 0.5dB
|
||||
highest - 0.0025mW
|
||||
fixed <25 - 65535> - units of 0.0001mW
|
||||
relative <0.00 - 10.00> - units of dB
|
||||
|
||||
For example, if you want to set the sensitivity to medium level, then you enter word
|
||||
|
||||
medium
|
||||
|
||||
Or if you want to set it to a fixed value, then you enter string
|
||||
|
||||
fixed 1000
|
||||
|
||||
Or if you want to set to a relative value, then you enter string
|
||||
|
||||
relative 1.20
|
||||
"
|
||||
::= { atFiberMonConfigEntry 4 }
|
||||
|
||||
atFiberMonBaseline OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The baseline value for firber mornitoring.
|
||||
|
||||
Acceptable mode string and value ranges are as below:
|
||||
|
||||
average <12-150> - number of readings used to calculate moving average.
|
||||
fixed <1-65535> - fixed baseline value in units of 0.0001mW.
|
||||
|
||||
For example, if you want to use a moving average of 12 readings as the baseline,
|
||||
you enter
|
||||
|
||||
average 12
|
||||
|
||||
Or if you want to use a fixed value, though it is not recommended, you enter
|
||||
|
||||
fixed 500
|
||||
"
|
||||
::= { atFiberMonConfigEntry 5 }
|
||||
|
||||
atFiberMonAlarmAction OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
logOnly(1),
|
||||
sendTrap(2),
|
||||
shutdown(3),
|
||||
sendtrapAndShutdown(4)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Actions to take when an alarm occurs.
|
||||
Acceptable values are:
|
||||
1. Log a message only.
|
||||
2. Send snmp trap and log.
|
||||
3. Shut down the interface and log.
|
||||
4. Send trap, shutdown and log.
|
||||
"
|
||||
::= { atFiberMonConfigEntry 6 }
|
||||
|
||||
-- ---------------------------------------------------------- --
|
||||
-- Fiber monitoring state objects
|
||||
-- ---------------------------------------------------------- --
|
||||
atFiberMonStateTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF AtFiberMonStateEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains the information of fiber monitoring state for SFPs."
|
||||
::= { atFiberMon 3 }
|
||||
|
||||
atFiberMonStateEntry OBJECT-TYPE
|
||||
SYNTAX AtFiberMonStateEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Entry for fiber monitoring state table. It contains state values for a fiber channel."
|
||||
INDEX { atFiberMonIfindex, atFiberMonChannel }
|
||||
::= { atFiberMonStateTable 1 }
|
||||
|
||||
AtFiberMonStateEntry ::=
|
||||
SEQUENCE {
|
||||
atFiberMonIfindex
|
||||
Integer32,
|
||||
atFiberMonChannel
|
||||
INTEGER,
|
||||
atFiberMonlIfDescription
|
||||
DisplayString,
|
||||
atFiberMonActualBaseline
|
||||
Integer32,
|
||||
atFiberMonThreshold
|
||||
Integer32,
|
||||
atFiberMonReadingHistory
|
||||
DisplayString,
|
||||
atFiberMonMinReading
|
||||
Integer32,
|
||||
atFiberMonMaxReading
|
||||
Integer32
|
||||
}
|
||||
|
||||
atFiberMonIfindex OBJECT-TYPE
|
||||
SYNTAX Integer32 (1..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The index of the interface where the pluggable is in."
|
||||
::= { atFiberMonStateEntry 1 }
|
||||
|
||||
atFiberMonChannel OBJECT-TYPE
|
||||
SYNTAX INTEGER (1..16)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The channel number of the pluggable."
|
||||
::= { atFiberMonStateEntry 2 }
|
||||
|
||||
atFiberMonlIfDescription OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Interface description. Normally it would be the name of the interface."
|
||||
::= { atFiberMonStateEntry 3 }
|
||||
|
||||
atFiberMonActualBaseline OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..65535)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The calculated baseline value for the link, in units of 0.0001mW."
|
||||
::= { atFiberMonStateEntry 4 }
|
||||
|
||||
atFiberMonThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..65535)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Threshold value for alarm to occur, in units of 0.0001mW."
|
||||
::= { atFiberMonStateEntry 5 }
|
||||
|
||||
atFiberMonReadingHistory OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The reading history. It is a string containing last 12 readings."
|
||||
::= { atFiberMonStateEntry 6 }
|
||||
|
||||
atFiberMonMinReading OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..65535)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The minimum reading of rx power, in units of 0.0001mW."
|
||||
::= { atFiberMonStateEntry 7 }
|
||||
|
||||
atFiberMonMaxReading OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..65535)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The maximum reading of rx power, in units of 0.0001mW."
|
||||
::= { atFiberMonStateEntry 8 }
|
||||
|
||||
|
||||
END
|
||||
|
||||
--
|
||||