Initial commit
This commit is contained in:
		
							
								
								
									
										493
									
								
								MIBS/bktel/BKTEL-HFC862-HMSNE-MIB
									
									
									
									
									
										Normal file
									
								
							
							
						
						
									
										493
									
								
								MIBS/bktel/BKTEL-HFC862-HMSNE-MIB
									
									
									
									
									
										Normal file
									
								
							@@ -0,0 +1,493 @@
 | 
			
		||||
-- ******************************************************************************************
 | 
			
		||||
-- *
 | 
			
		||||
-- * Description:   Implements definitions for a HMS based network element
 | 
			
		||||
-- *
 | 
			
		||||
-- * Copyright 2014 by BKtel communications GmbH
 | 
			
		||||
-- *
 | 
			
		||||
-- * V.1.0  04.10.2006  M. Heldmann - created this "bkhmsne.mib" file based on BKtel systems "ahmsne.mib" file
 | 
			
		||||
-- *                                - marked all parameters that are not used by NMS implementation of BKtel communications GmbH
 | 
			
		||||
-- *                                - removed the 'ne' OID definition here and added 'ne' to IMPORTS
 | 
			
		||||
-- *                                  because the 'ne' is defined in root mib too
 | 
			
		||||
-- * V.1.1  12.05.2014  M. Heldmann - marked all obsolete parameters as 'obsolete' - they may be no more supported by future NEC types and NEC software versions
 | 
			
		||||
-- *                                - expanded neModulTable by full inventory information
 | 
			
		||||
-- *                                - a couple of renamings
 | 
			
		||||
-- *                                - changed name neModulType to neModuleModelName with SYNTAX DisplayString
 | 
			
		||||
-- ******************************************************************************************
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
    BKTEL-HFC862-HMSNE-MIB DEFINITIONS ::= BEGIN
 | 
			
		||||
 | 
			
		||||
    IMPORTS
 | 
			
		||||
        OBJECT-TYPE
 | 
			
		||||
            FROM RFC-1212
 | 
			
		||||
        TRAP-TYPE
 | 
			
		||||
            FROM RFC-1215
 | 
			
		||||
        ne, DisplayString, TruthValue, NESlotValue, PerceivedSeverityValue
 | 
			
		||||
            FROM BKTEL-HFC862-BASE-MIB
 | 
			
		||||
    ;
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
    neCommon OBJECT IDENTIFIER ::= { ne 1 }
 | 
			
		||||
 | 
			
		||||
    neType OBJECT-TYPE
 | 
			
		||||
        SYNTAX DisplayString
 | 
			
		||||
        ACCESS read-only
 | 
			
		||||
        STATUS mandatory
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "Type of NE"
 | 
			
		||||
    ::= { neCommon 1 }
 | 
			
		||||
 | 
			
		||||
    neDescription OBJECT-TYPE
 | 
			
		||||
        SYNTAX DisplayString
 | 
			
		||||
        ACCESS read-only
 | 
			
		||||
        STATUS mandatory
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "The description of the NE."
 | 
			
		||||
    ::= { neCommon 2 }
 | 
			
		||||
 | 
			
		||||
    neLocationStreet OBJECT-TYPE
 | 
			
		||||
        SYNTAX DisplayString
 | 
			
		||||
        ACCESS read-write
 | 
			
		||||
        STATUS mandatory
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "Location Street of Network Element.
 | 
			
		||||
             Writable size depends on net element controller, default 32"
 | 
			
		||||
    ::= { neCommon 3 }
 | 
			
		||||
 | 
			
		||||
    neLocationCity OBJECT-TYPE
 | 
			
		||||
        SYNTAX DisplayString
 | 
			
		||||
        ACCESS read-write
 | 
			
		||||
        STATUS mandatory
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "Location City of Network Element.
 | 
			
		||||
             Writable size depends on net element controller, default 32"
 | 
			
		||||
    ::= { neCommon 4 }
 | 
			
		||||
 | 
			
		||||
    neObsolete_UsingAPS OBJECT-TYPE
 | 
			
		||||
        SYNTAX TruthValue
 | 
			
		||||
        ACCESS read-only
 | 
			
		||||
        STATUS obsolete
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This parameter is obsolete."
 | 
			
		||||
    ::= { neCommon 5 }
 | 
			
		||||
 | 
			
		||||
    neObsolete_APSMode OBJECT-TYPE
 | 
			
		||||
        SYNTAX INTEGER
 | 
			
		||||
        ACCESS read-write
 | 
			
		||||
        STATUS obsolete
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This parameter is obsolete."
 | 
			
		||||
    ::= { neCommon 6 }
 | 
			
		||||
 | 
			
		||||
    -- #####+1 Space reserved
 | 
			
		||||
 | 
			
		||||
    neObsolete_CommonSubrackWidth OBJECT-TYPE
 | 
			
		||||
        SYNTAX INTEGER
 | 
			
		||||
        ACCESS read-only
 | 
			
		||||
        STATUS obsolete
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This parameter is obsolete.
 | 
			
		||||
             (The width of the Subracks)"
 | 
			
		||||
    ::= { neCommon 8 }
 | 
			
		||||
 | 
			
		||||
    neObsolete_CommonSubrackNumber OBJECT-TYPE
 | 
			
		||||
        SYNTAX INTEGER
 | 
			
		||||
        ACCESS read-only
 | 
			
		||||
        STATUS obsolete
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This parameter is obsolete.
 | 
			
		||||
             (The number of Subracks)"
 | 
			
		||||
    ::= { neCommon 9 }
 | 
			
		||||
 | 
			
		||||
    neObsolete_NumberModul OBJECT-TYPE
 | 
			
		||||
        SYNTAX INTEGER (1..61)
 | 
			
		||||
        ACCESS read-only
 | 
			
		||||
        STATUS obsolete
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This parameter is obsolete.
 | 
			
		||||
             (Current number of entries in the Modul table)"
 | 
			
		||||
    ::= { neCommon 10 }
 | 
			
		||||
 | 
			
		||||
    neObsolete_UsingRevertiveMode OBJECT-TYPE
 | 
			
		||||
        SYNTAX TruthValue
 | 
			
		||||
        ACCESS read-only
 | 
			
		||||
        STATUS obsolete
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This parameter is obsolete."
 | 
			
		||||
    ::= { neCommon 11 }
 | 
			
		||||
 | 
			
		||||
    neObsolete_RevertiveMode OBJECT-TYPE
 | 
			
		||||
        SYNTAX INTEGER (0..300)
 | 
			
		||||
        ACCESS read-write
 | 
			
		||||
        STATUS obsolete
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This parameter is obsolete."
 | 
			
		||||
    ::= { neCommon 12 }
 | 
			
		||||
 | 
			
		||||
    neObsolete_InitPhase OBJECT-TYPE
 | 
			
		||||
        SYNTAX INTEGER
 | 
			
		||||
        ACCESS read-only
 | 
			
		||||
        STATUS obsolete
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This parameter is obsolete."
 | 
			
		||||
    ::= { neCommon 13 }
 | 
			
		||||
 | 
			
		||||
    neObsolete_PredecessorRedundantPath OBJECT-TYPE
 | 
			
		||||
        SYNTAX IpAddress
 | 
			
		||||
        ACCESS read-write
 | 
			
		||||
        STATUS obsolete
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This parameter is obsolete."
 | 
			
		||||
    ::= { neCommon 14 }
 | 
			
		||||
 | 
			
		||||
    neObsolete_PredecessorNominalPath OBJECT-TYPE
 | 
			
		||||
        SYNTAX IpAddress
 | 
			
		||||
        ACCESS read-write
 | 
			
		||||
        STATUS obsolete
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This parameter is obsolete."
 | 
			
		||||
    ::= { neCommon 15 }
 | 
			
		||||
 | 
			
		||||
    neModuleTable OBJECT-TYPE
 | 
			
		||||
        SYNTAX SEQUENCE OF NeModuleEntry
 | 
			
		||||
        ACCESS not-accessible
 | 
			
		||||
        STATUS mandatory
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "Table containing information about each Module."
 | 
			
		||||
    ::= { neCommon 16 }
 | 
			
		||||
 | 
			
		||||
    neModuleEntry OBJECT-TYPE
 | 
			
		||||
        SYNTAX NeModuleEntry
 | 
			
		||||
        ACCESS not-accessible
 | 
			
		||||
        STATUS mandatory
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "List of information about each Module."
 | 
			
		||||
        INDEX { neModuleNESlot }
 | 
			
		||||
    ::= { neModuleTable 1 }
 | 
			
		||||
 | 
			
		||||
    NeModuleEntry ::= SEQUENCE
 | 
			
		||||
    {
 | 
			
		||||
        neModuleNESlot                  NESlotValue,
 | 
			
		||||
        neModuleSubrack                 INTEGER,
 | 
			
		||||
        neModuleModelName               DisplayString,
 | 
			
		||||
        neModuleMibLink                 OBJECT IDENTIFIER,
 | 
			
		||||
        neModuleSubrackSlot             INTEGER,
 | 
			
		||||
        neModuleSlotUnitsUsed           INTEGER,
 | 
			
		||||
        neModuleSlotRackDetection       INTEGER,
 | 
			
		||||
        neModuleHousingType             INTEGER,
 | 
			
		||||
        neModuleFirmwareVersion         DisplayString,
 | 
			
		||||
        neModuleHardwareVersion         DisplayString,
 | 
			
		||||
        neModuleDateOfProduction        DisplayString,
 | 
			
		||||
        neModuleSerialNumber            DisplayString,
 | 
			
		||||
        neModuleArticleNumber           DisplayString,
 | 
			
		||||
        neModuleCustomerCode            DisplayString,
 | 
			
		||||
        neModuleAliasName               DisplayString,
 | 
			
		||||
        neModuleUserdata                DisplayString,
 | 
			
		||||
        neModuleReset                   TruthValue,
 | 
			
		||||
        neModuleLedBlink                TruthValue
 | 
			
		||||
    }
 | 
			
		||||
 | 
			
		||||
    neModuleNESlot OBJECT-TYPE      -- former neNESlot
 | 
			
		||||
        SYNTAX NESlotValue
 | 
			
		||||
        ACCESS read-only
 | 
			
		||||
        STATUS mandatory
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "Slot number 
 | 
			
		||||
             IMPORTANT NOTE:
 | 
			
		||||
                this is a not a physical slot within a module rack, 
 | 
			
		||||
                but an assigned slot ID that uniquely identifies each module
 | 
			
		||||
                including non subrack based modules as 19 inch modules"
 | 
			
		||||
    ::= { neModuleEntry 1 }
 | 
			
		||||
 | 
			
		||||
    neModuleSubrack OBJECT-TYPE     -- former neSubrack
 | 
			
		||||
        SYNTAX INTEGER
 | 
			
		||||
        ACCESS read-only
 | 
			
		||||
        STATUS mandatory
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "Subrack number in which the module is equiped (1 .. N).
 | 
			
		||||
             A value of 0 means: No subrack number"
 | 
			
		||||
    ::= { neModuleEntry 2 }
 | 
			
		||||
 | 
			
		||||
    neModuleModelName OBJECT-TYPE   -- former neModulType
 | 
			
		||||
        SYNTAX DisplayString
 | 
			
		||||
        ACCESS read-only
 | 
			
		||||
        STATUS mandatory
 | 
			
		||||
        DESCRIPTION "Module model name"
 | 
			
		||||
    ::= { neModuleEntry 3 }
 | 
			
		||||
 | 
			
		||||
    neModuleMibLink OBJECT-TYPE     -- former neModulMibLink
 | 
			
		||||
        SYNTAX OBJECT IDENTIFIER
 | 
			
		||||
        ACCESS read-only
 | 
			
		||||
        STATUS mandatory
 | 
			
		||||
        DESCRIPTION "Defines the link to the OID of the equiped module"
 | 
			
		||||
    ::= { neModuleEntry 4 }
 | 
			
		||||
 | 
			
		||||
    -- Expansions, 12.05.2014
 | 
			
		||||
 | 
			
		||||
    neModuleSubrackSlot OBJECT-TYPE
 | 
			
		||||
        SYNTAX INTEGER
 | 
			
		||||
        ACCESS read-only
 | 
			
		||||
        STATUS mandatory
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "Slot number within subrack in which the module is equiped (1 .. N).
 | 
			
		||||
             A value of 0 means: No slot number"
 | 
			
		||||
    ::= { neModuleEntry 5 }
 | 
			
		||||
 | 
			
		||||
    neModuleSlotUnitsUsed OBJECT-TYPE
 | 
			
		||||
        SYNTAX INTEGER
 | 
			
		||||
        ACCESS read-only
 | 
			
		||||
        STATUS mandatory
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "For modules of type 'housing19inch(4)' this parameter specfifies the number of 19 inch height units used. 
 | 
			
		||||
             For all other module types the number of slots within subrack which the module occupies."
 | 
			
		||||
    ::= { neModuleEntry 6 }
 | 
			
		||||
 | 
			
		||||
    neModuleSlotRackDetection OBJECT-TYPE
 | 
			
		||||
        SYNTAX INTEGER
 | 
			
		||||
        {
 | 
			
		||||
            notSupported(1),
 | 
			
		||||
            supported(2),
 | 
			
		||||
            detectionError(3)
 | 
			
		||||
        }
 | 
			
		||||
        ACCESS read-only
 | 
			
		||||
        STATUS mandatory
 | 
			
		||||
        DESCRIPTION "Reports the state of modules slot and rack hardware detection."
 | 
			
		||||
    ::= { neModuleEntry 7 }
 | 
			
		||||
 | 
			
		||||
    neModuleHousingType OBJECT-TYPE
 | 
			
		||||
        SYNTAX INTEGER
 | 
			
		||||
        {
 | 
			
		||||
            housingUnknownOrDefault(1),
 | 
			
		||||
            housingBk(2),
 | 
			
		||||
            housing2G6(3),
 | 
			
		||||
            housing19inch(4)
 | 
			
		||||
        }
 | 
			
		||||
        ACCESS read-only
 | 
			
		||||
        STATUS mandatory
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "Module housing type"
 | 
			
		||||
    ::= { neModuleEntry 8 }
 | 
			
		||||
 | 
			
		||||
    neModuleFirmwareVersion OBJECT-TYPE
 | 
			
		||||
        SYNTAX  DisplayString
 | 
			
		||||
        ACCESS  read-only
 | 
			
		||||
        STATUS  mandatory
 | 
			
		||||
        DESCRIPTION "Module firmware version"
 | 
			
		||||
    ::= { neModuleEntry 9 }
 | 
			
		||||
 | 
			
		||||
    neModuleHardwareVersion OBJECT-TYPE
 | 
			
		||||
        SYNTAX  DisplayString
 | 
			
		||||
        ACCESS  read-only
 | 
			
		||||
        STATUS  mandatory
 | 
			
		||||
        DESCRIPTION "Module hardware version"
 | 
			
		||||
    ::= { neModuleEntry 10 }
 | 
			
		||||
 | 
			
		||||
    neModuleDateOfProduction OBJECT-TYPE
 | 
			
		||||
        SYNTAX  DisplayString
 | 
			
		||||
        ACCESS  read-only
 | 
			
		||||
        STATUS  mandatory
 | 
			
		||||
        DESCRIPTION "Module date of production, possible formats:
 | 
			
		||||
            - empty string -> no data defined
 | 
			
		||||
            - YYYY         -> only the year of production is defined
 | 
			
		||||
            - YYYY-MM-DD   -> full date of production is defined"
 | 
			
		||||
    ::= { neModuleEntry 11 }
 | 
			
		||||
 | 
			
		||||
    neModuleSerialNumber OBJECT-TYPE
 | 
			
		||||
        SYNTAX  DisplayString
 | 
			
		||||
        ACCESS  read-only
 | 
			
		||||
        STATUS  mandatory
 | 
			
		||||
        DESCRIPTION "Module serial number"
 | 
			
		||||
    ::= { neModuleEntry 12 }
 | 
			
		||||
 | 
			
		||||
    neModuleArticleNumber OBJECT-TYPE
 | 
			
		||||
        SYNTAX  DisplayString
 | 
			
		||||
        ACCESS  read-only
 | 
			
		||||
        STATUS  mandatory
 | 
			
		||||
        DESCRIPTION "Module article number"
 | 
			
		||||
    ::= { neModuleEntry 13 }
 | 
			
		||||
 | 
			
		||||
    neModuleCustomerCode OBJECT-TYPE
 | 
			
		||||
        SYNTAX  DisplayString
 | 
			
		||||
        ACCESS  read-only
 | 
			
		||||
        STATUS  mandatory
 | 
			
		||||
        DESCRIPTION "Customer specific article code"
 | 
			
		||||
    ::= { neModuleEntry 14 }
 | 
			
		||||
 | 
			
		||||
    neModuleAliasName OBJECT-TYPE
 | 
			
		||||
        SYNTAX  DisplayString
 | 
			
		||||
        ACCESS  read-write
 | 
			
		||||
        STATUS  mandatory
 | 
			
		||||
        DESCRIPTION "Module alias name"
 | 
			
		||||
    ::= { neModuleEntry 15 }
 | 
			
		||||
 | 
			
		||||
    neModuleUserdata OBJECT-TYPE
 | 
			
		||||
        SYNTAX  DisplayString
 | 
			
		||||
        ACCESS  read-write
 | 
			
		||||
        STATUS  mandatory
 | 
			
		||||
        DESCRIPTION "Module user data"
 | 
			
		||||
    ::= { neModuleEntry 16 }
 | 
			
		||||
 | 
			
		||||
    neModuleReset OBJECT-TYPE
 | 
			
		||||
        SYNTAX TruthValue
 | 
			
		||||
        ACCESS read-write
 | 
			
		||||
        STATUS mandatory
 | 
			
		||||
        DESCRIPTION "Resets the module if this parameter is written to true(1)."
 | 
			
		||||
    ::= { neModuleEntry 17 }
 | 
			
		||||
 | 
			
		||||
    neModuleLedBlink OBJECT-TYPE
 | 
			
		||||
        SYNTAX TruthValue
 | 
			
		||||
        ACCESS read-write
 | 
			
		||||
        STATUS mandatory
 | 
			
		||||
        DESCRIPTION   "Writing this variable to true(1) lets the device's
 | 
			
		||||
        modul LED blink green for 10 seconds.
 | 
			
		||||
        Writing this variable to false(2) stops blinking at once.
 | 
			
		||||
        This variable always returns false(2) on read requests"
 | 
			
		||||
    ::= { neModuleEntry 18 }
 | 
			
		||||
 | 
			
		||||
    neStates OBJECT IDENTIFIER ::= { ne 2 }
 | 
			
		||||
 | 
			
		||||
    neStatesObsolete_TrapDisable OBJECT-TYPE
 | 
			
		||||
        SYNTAX PerceivedSeverityValue
 | 
			
		||||
        ACCESS read-only
 | 
			
		||||
        STATUS obsolete
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This parameter is obsolete."
 | 
			
		||||
    ::= { neStates 1 }
 | 
			
		||||
 | 
			
		||||
    neStatesObsolete_TerminalConnected OBJECT-TYPE
 | 
			
		||||
        SYNTAX PerceivedSeverityValue
 | 
			
		||||
        ACCESS read-only
 | 
			
		||||
        STATUS obsolete
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This parameter is obsolete."
 | 
			
		||||
    ::= { neStates 2 }
 | 
			
		||||
 | 
			
		||||
    -- #####+1 Space reserved
 | 
			
		||||
 | 
			
		||||
    neStatesObsolete_Isolated OBJECT-TYPE
 | 
			
		||||
        SYNTAX PerceivedSeverityValue
 | 
			
		||||
        ACCESS read-only
 | 
			
		||||
        STATUS obsolete
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This parameter is obsolete."
 | 
			
		||||
    ::= { neStates 4 }
 | 
			
		||||
 | 
			
		||||
    neStatesObsolete_ResetModullist OBJECT-TYPE
 | 
			
		||||
        SYNTAX PerceivedSeverityValue
 | 
			
		||||
        ACCESS read-only
 | 
			
		||||
        STATUS obsolete
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This parameter is obsolete."
 | 
			
		||||
    ::= { neStates 5 }
 | 
			
		||||
 | 
			
		||||
    neStatesObsolete_Redundant OBJECT-TYPE
 | 
			
		||||
        SYNTAX PerceivedSeverityValue
 | 
			
		||||
        ACCESS read-only
 | 
			
		||||
        STATUS obsolete
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This parameter is obsolete."
 | 
			
		||||
    ::= { neStates 6 }
 | 
			
		||||
 | 
			
		||||
    neStatesObsolete_ActivateRedundantPath OBJECT-TYPE
 | 
			
		||||
        SYNTAX PerceivedSeverityValue
 | 
			
		||||
        ACCESS read-only
 | 
			
		||||
        STATUS obsolete
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This parameter is obsolete."
 | 
			
		||||
    ::= { neStates 7 }
 | 
			
		||||
 | 
			
		||||
    neStatesObsolete_AutoOff OBJECT-TYPE
 | 
			
		||||
        SYNTAX PerceivedSeverityValue
 | 
			
		||||
        ACCESS read-only
 | 
			
		||||
        STATUS obsolete
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This parameter is obsolete."
 | 
			
		||||
    ::= { neStates 8 }
 | 
			
		||||
 | 
			
		||||
    neConfig OBJECT IDENTIFIER ::= { ne 3 }
 | 
			
		||||
 | 
			
		||||
    neConfigObsolete_NEtype OBJECT-TYPE
 | 
			
		||||
        SYNTAX INTEGER
 | 
			
		||||
        ACCESS read-write
 | 
			
		||||
        STATUS obsolete
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This parameter is obsolete."
 | 
			
		||||
    ::= { neConfig 1 }
 | 
			
		||||
 | 
			
		||||
    neConfigObsolete_IPaddress OBJECT-TYPE
 | 
			
		||||
        SYNTAX IpAddress
 | 
			
		||||
        ACCESS read-write
 | 
			
		||||
        STATUS obsolete
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This parameter is obsolete."
 | 
			
		||||
    ::= { neConfig 2 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
    neConfigObsolete_Alarmdelay OBJECT-TYPE
 | 
			
		||||
        SYNTAX INTEGER (3..60)
 | 
			
		||||
        ACCESS read-write
 | 
			
		||||
        STATUS obsolete
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This parameter is obsolete."
 | 
			
		||||
    ::= { neConfig 3 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
    neConfigDeprecated_MinTrapInterval OBJECT-TYPE
 | 
			
		||||
        SYNTAX INTEGER (0..10)
 | 
			
		||||
        ACCESS read-write
 | 
			
		||||
        STATUS optional
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This parameter is deprecated.
 | 
			
		||||
             (The minimum waiting time between two traps.
 | 
			
		||||
              Only used for HMS070 over RS232 interface)"
 | 
			
		||||
    ::= { neConfig 4 }
 | 
			
		||||
 | 
			
		||||
    neConfigDeprecated_MaxTrapLifetime OBJECT-TYPE
 | 
			
		||||
        SYNTAX INTEGER (30..300)
 | 
			
		||||
        ACCESS read-write
 | 
			
		||||
        STATUS optional
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This parameter is deprecated.
 | 
			
		||||
             (The maximum lifetime of a trap.
 | 
			
		||||
              Only used for HMS070 over RS232 interface)"
 | 
			
		||||
    ::= { neConfig 5 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
    neControl OBJECT IDENTIFIER ::= { ne 4 }
 | 
			
		||||
 | 
			
		||||
    neControlTrapDisable OBJECT-TYPE
 | 
			
		||||
        SYNTAX TruthValue
 | 
			
		||||
        ACCESS read-write
 | 
			
		||||
        STATUS mandatory
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "All traps and notifications for the whole NE are disabled: true(1) or enabled: false(2)"
 | 
			
		||||
    ::= { neControl 1 }
 | 
			
		||||
 | 
			
		||||
    neControlResetModullist OBJECT-TYPE
 | 
			
		||||
        SYNTAX TruthValue
 | 
			
		||||
        ACCESS read-write
 | 
			
		||||
        STATUS mandatory
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This command removes all disconnected (not responding) modules from the module list."
 | 
			
		||||
    ::= { neControl 2 }
 | 
			
		||||
 | 
			
		||||
    neControlObsolete_SetDefaultAPS OBJECT-TYPE
 | 
			
		||||
        SYNTAX TruthValue
 | 
			
		||||
        ACCESS read-write
 | 
			
		||||
        STATUS obsolete
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This parameter is obsolete."
 | 
			
		||||
    ::= { neControl 3 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
    -- This trap is obsolete and no more supported by new (2014) NECxE 
 | 
			
		||||
    neSynchronizeEvent TRAP-TYPE
 | 
			
		||||
    ENTERPRISE ne
 | 
			
		||||
    DESCRIPTION "The SNMP trap that is generated when data on LMT must get actualized."
 | 
			
		||||
    ::= 1
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
    END
 | 
			
		||||
		Reference in New Issue
	