-- * Description: Implements definitions for a HMS based network element
|
||||
-- *
|
||||
-- * Copyright 2014 by BKtel communications GmbH
|
||||
-- *
|
||||
-- * V.1.0 04.10.2006 M. Heldmann - created this "bkhmsne.mib" file based on BKtel systems "ahmsne.mib" file
|
||||
-- * - marked all parameters that are not used by NMS implementation of BKtel communications GmbH
|
||||
-- * - removed the 'ne' OID definition here and added 'ne' to IMPORTS
|
||||
-- * because the 'ne' is defined in root mib too
|
||||
-- * V.1.1 12.05.2014 M. Heldmann - marked all obsolete parameters as 'obsolete' - they may be no more supported by future NEC types and NEC software versions
|
||||
-- * - expanded neModulTable by full inventory information
|
||||
-- * - a couple of renamings
|
||||
-- * - changed name neModulType to neModuleModelName with SYNTAX DisplayString
|
||||
-- ******************************************************************************************
|
||||
|
||||
|
||||
BKTEL-HFC862-HMSNE-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
OBJECT-TYPE
|
||||
FROM RFC-1212
|
||||
TRAP-TYPE
|
||||
FROM RFC-1215
|
||||
ne, DisplayString, TruthValue, NESlotValue, PerceivedSeverityValue
|
||||
FROM BKTEL-HFC862-BASE-MIB
|
||||
;
|
||||
|
||||
|
||||
neCommon OBJECT IDENTIFIER ::= { ne 1 }
|
||||
|
||||
neType OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Type of NE"
|
||||
::= { neCommon 1 }
|
||||
|
||||
neDescription OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The description of the NE."
|
||||
::= { neCommon 2 }
|
||||
|
||||
neLocationStreet OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Location Street of Network Element.
|
||||
Writable size depends on net element controller, default 32"
|
||||
::= { neCommon 3 }
|
||||
|
||||
neLocationCity OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Location City of Network Element.
|
||||
Writable size depends on net element controller, default 32"
|
||||
::= { neCommon 4 }
|
||||
|
||||
neObsolete_UsingAPS OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
ACCESS read-only
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"This parameter is obsolete."
|
||||
::= { neCommon 5 }
|
||||
|
||||
neObsolete_APSMode OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-write
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"This parameter is obsolete."
|
||||
::= { neCommon 6 }
|
||||
|
||||
-- #####+1 Space reserved
|
||||
|
||||
neObsolete_CommonSubrackWidth OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"This parameter is obsolete.
|
||||
(The width of the Subracks)"
|
||||
::= { neCommon 8 }
|
||||
|
||||
neObsolete_CommonSubrackNumber OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"This parameter is obsolete.
|
||||
(The number of Subracks)"
|
||||
::= { neCommon 9 }
|
||||
|
||||
neObsolete_NumberModul OBJECT-TYPE
|
||||
SYNTAX INTEGER (1..61)
|
||||
ACCESS read-only
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"This parameter is obsolete.
|
||||
(Current number of entries in the Modul table)"
|
||||
::= { neCommon 10 }
|
||||
|
||||
neObsolete_UsingRevertiveMode OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
ACCESS read-only
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"This parameter is obsolete."
|
||||
::= { neCommon 11 }
|
||||
|
||||
neObsolete_RevertiveMode OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..300)
|
||||
ACCESS read-write
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"This parameter is obsolete."
|
||||
::= { neCommon 12 }
|
||||
|
||||
neObsolete_InitPhase OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"This parameter is obsolete."
|
||||
::= { neCommon 13 }
|
||||
|
||||
neObsolete_PredecessorRedundantPath OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
ACCESS read-write
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"This parameter is obsolete."
|
||||
::= { neCommon 14 }
|
||||
|
||||
neObsolete_PredecessorNominalPath OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
ACCESS read-write
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"This parameter is obsolete."
|
||||
::= { neCommon 15 }
|
||||
|
||||
neModuleTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF NeModuleEntry
|
||||
ACCESS not-accessible
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Table containing information about each Module."
|
||||
::= { neCommon 16 }
|
||||
|
||||
neModuleEntry OBJECT-TYPE
|
||||
SYNTAX NeModuleEntry
|
||||
ACCESS not-accessible
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"List of information about each Module."
|
||||
INDEX { neModuleNESlot }
|
||||
::= { neModuleTable 1 }
|
||||
|
||||
NeModuleEntry ::= SEQUENCE
|
||||
{
|
||||
neModuleNESlot NESlotValue,
|
||||
neModuleSubrack INTEGER,
|
||||
neModuleModelName DisplayString,
|
||||
neModuleMibLink OBJECT IDENTIFIER,
|
||||
neModuleSubrackSlot INTEGER,
|
||||
neModuleSlotUnitsUsed INTEGER,
|
||||
neModuleSlotRackDetection INTEGER,
|
||||
neModuleHousingType INTEGER,
|
||||
neModuleFirmwareVersion DisplayString,
|
||||
neModuleHardwareVersion DisplayString,
|
||||
neModuleDateOfProduction DisplayString,
|
||||
neModuleSerialNumber DisplayString,
|
||||
neModuleArticleNumber DisplayString,
|
||||
neModuleCustomerCode DisplayString,
|
||||
neModuleAliasName DisplayString,
|
||||
neModuleUserdata DisplayString,
|
||||
neModuleReset TruthValue,
|
||||
neModuleLedBlink TruthValue
|
||||
}
|
||||
|
||||
neModuleNESlot OBJECT-TYPE -- former neNESlot
|
||||
SYNTAX NESlotValue
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Slot number
|
||||
IMPORTANT NOTE:
|
||||
this is a not a physical slot within a module rack,
|
||||
but an assigned slot ID that uniquely identifies each module
|
||||
including non subrack based modules as 19 inch modules"
|
||||
::= { neModuleEntry 1 }
|
||||
|
||||
neModuleSubrack OBJECT-TYPE -- former neSubrack
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Subrack number in which the module is equiped (1 .. N).
|
||||
A value of 0 means: No subrack number"
|
||||
::= { neModuleEntry 2 }
|
||||
|
||||
neModuleModelName OBJECT-TYPE -- former neModulType
|
||||
SYNTAX DisplayString
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Module model name"
|
||||
::= { neModuleEntry 3 }
|
||||
|
||||
neModuleMibLink OBJECT-TYPE -- former neModulMibLink
|
||||
SYNTAX OBJECT IDENTIFIER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Defines the link to the OID of the equiped module"
|
||||
::= { neModuleEntry 4 }
|
||||
|
||||
-- Expansions, 12.05.2014
|
||||
|
||||
neModuleSubrackSlot OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Slot number within subrack in which the module is equiped (1 .. N).
|
||||
A value of 0 means: No slot number"
|
||||
::= { neModuleEntry 5 }
|
||||
|
||||
neModuleSlotUnitsUsed OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"For modules of type 'housing19inch(4)' this parameter specfifies the number of 19 inch height units used.
|
||||
For all other module types the number of slots within subrack which the module occupies."
|
||||
::= { neModuleEntry 6 }
|
||||
|
||||
neModuleSlotRackDetection OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
notSupported(1),
|
||||
supported(2),
|
||||
detectionError(3)
|
||||
}
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Reports the state of modules slot and rack hardware detection."
|
||||
::= { neModuleEntry 7 }
|
||||
|
||||
neModuleHousingType OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
housingUnknownOrDefault(1),
|
||||
housingBk(2),
|
||||
housing2G6(3),
|
||||
housing19inch(4)
|
||||
}
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Module housing type"
|
||||
::= { neModuleEntry 8 }
|
||||
|
||||
neModuleFirmwareVersion OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Module firmware version"
|
||||
::= { neModuleEntry 9 }
|
||||
|
||||
neModuleHardwareVersion OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Module hardware version"
|
||||
::= { neModuleEntry 10 }
|
||||
|
||||
neModuleDateOfProduction OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Module date of production, possible formats:
|
||||
- empty string -> no data defined
|
||||
- YYYY -> only the year of production is defined
|
||||
- YYYY-MM-DD -> full date of production is defined"
|
||||
::= { neModuleEntry 11 }
|
||||
|
||||
neModuleSerialNumber OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Module serial number"
|
||||
::= { neModuleEntry 12 }
|
||||
|
||||
neModuleArticleNumber OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Module article number"
|
||||
::= { neModuleEntry 13 }
|
||||
|
||||
neModuleCustomerCode OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Customer specific article code"
|
||||
::= { neModuleEntry 14 }
|
||||
|
||||
neModuleAliasName OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Module alias name"
|
||||
::= { neModuleEntry 15 }
|
||||
|
||||
neModuleUserdata OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Module user data"
|
||||
::= { neModuleEntry 16 }
|
||||
|
||||
neModuleReset OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Resets the module if this parameter is written to true(1)."
|
||||
::= { neModuleEntry 17 }
|
||||
|
||||
neModuleLedBlink OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION "Writing this variable to true(1) lets the device's
|
||||
modul LED blink green for 10 seconds.
|
||||
Writing this variable to false(2) stops blinking at once.
|
||||
This variable always returns false(2) on read requests"
|
||||
::= { neModuleEntry 18 }
|
||||
|
||||
neStates OBJECT IDENTIFIER ::= { ne 2 }
|
||||
|
||||
neStatesObsolete_TrapDisable OBJECT-TYPE
|
||||
SYNTAX PerceivedSeverityValue
|
||||
ACCESS read-only
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"This parameter is obsolete."
|
||||
::= { neStates 1 }
|
||||
|
||||
neStatesObsolete_TerminalConnected OBJECT-TYPE
|
||||
SYNTAX PerceivedSeverityValue
|
||||
ACCESS read-only
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"This parameter is obsolete."
|
||||
::= { neStates 2 }
|
||||
|
||||
-- #####+1 Space reserved
|
||||
|
||||
neStatesObsolete_Isolated OBJECT-TYPE
|
||||
SYNTAX PerceivedSeverityValue
|
||||
ACCESS read-only
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"This parameter is obsolete."
|
||||
::= { neStates 4 }
|
||||
|
||||
neStatesObsolete_ResetModullist OBJECT-TYPE
|
||||
SYNTAX PerceivedSeverityValue
|
||||
ACCESS read-only
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"This parameter is obsolete."
|
||||
::= { neStates 5 }
|
||||
|
||||
neStatesObsolete_Redundant OBJECT-TYPE
|
||||
SYNTAX PerceivedSeverityValue
|
||||
ACCESS read-only
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"This parameter is obsolete."
|
||||
::= { neStates 6 }
|
||||
|
||||
neStatesObsolete_ActivateRedundantPath OBJECT-TYPE
|
||||
SYNTAX PerceivedSeverityValue
|
||||
ACCESS read-only
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"This parameter is obsolete."
|
||||
::= { neStates 7 }
|
||||
|
||||
neStatesObsolete_AutoOff OBJECT-TYPE
|
||||
SYNTAX PerceivedSeverityValue
|
||||
ACCESS read-only
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"This parameter is obsolete."
|
||||
::= { neStates 8 }
|
||||
|
||||
neConfig OBJECT IDENTIFIER ::= { ne 3 }
|
||||
|
||||
neConfigObsolete_NEtype OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-write
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"This parameter is obsolete."
|
||||
::= { neConfig 1 }
|
||||
|
||||
neConfigObsolete_IPaddress OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
ACCESS read-write
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"This parameter is obsolete."
|
||||
::= { neConfig 2 }
|
||||
|
||||
|
||||
neConfigObsolete_Alarmdelay OBJECT-TYPE
|
||||
SYNTAX INTEGER (3..60)
|
||||
ACCESS read-write
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"This parameter is obsolete."
|
||||
::= { neConfig 3 }
|
||||
|
||||
|
||||
neConfigDeprecated_MinTrapInterval OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..10)
|
||||
ACCESS read-write
|
||||
STATUS optional
|
||||
DESCRIPTION
|
||||
"This parameter is deprecated.
|
||||
(The minimum waiting time between two traps.
|
||||
Only used for HMS070 over RS232 interface)"
|
||||
::= { neConfig 4 }
|
||||
|
||||
neConfigDeprecated_MaxTrapLifetime OBJECT-TYPE
|
||||
SYNTAX INTEGER (30..300)
|
||||
ACCESS read-write
|
||||
STATUS optional
|
||||
DESCRIPTION
|
||||
"This parameter is deprecated.
|
||||
(The maximum lifetime of a trap.
|
||||
Only used for HMS070 over RS232 interface)"
|
||||
::= { neConfig 5 }
|
||||
|
||||
|
||||
|
||||
neControl OBJECT IDENTIFIER ::= { ne 4 }
|
||||
|
||||
neControlTrapDisable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"All traps and notifications for the whole NE are disabled: true(1) or enabled: false(2)"
|
||||
::= { neControl 1 }
|
||||
|
||||
neControlResetModullist OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This command removes all disconnected (not responding) modules from the module list."
|
||||
::= { neControl 2 }
|
||||
|
||||
neControlObsolete_SetDefaultAPS OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
ACCESS read-write
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"This parameter is obsolete."
|
||||
::= { neControl 3 }
|
||||
|
||||
|
||||
|
||||
|
||||
-- This trap is obsolete and no more supported by new (2014) NECxE
|
||||
neSynchronizeEvent TRAP-TYPE
|
||||
ENTERPRISE ne
|
||||
DESCRIPTION "The SNMP trap that is generated when data on LMT must get actualized."
|
||||
::= 1
|
||||
|
||||
|
||||
END
|