Initial commit
This commit is contained in:
718
MIBS/calix/E5-121-TRAPS-MIB
Normal file
718
MIBS/calix/E5-121-TRAPS-MIB
Normal file
@ -0,0 +1,718 @@
|
||||
-- $Log: E5-121-TRAPS-MIB.mib $
|
||||
-- Revision 1.8 2010/11/12 02:58:59 cylien
|
||||
-- Revision 1.7 2010/10/14 08:58:34 cylien
|
||||
-- Revision 1.6 2010/09/23 07:59:18 cylien
|
||||
-- Revision 1.5 2010/07/19 05:36:18 John
|
||||
-- Revision 1.4 2010/06/30 08:43:23 John
|
||||
-- Revision 1.4 2010/06/28 17:05:07 John
|
||||
-- Revision 1.3 2010/06/08 03:55:46 cylien
|
||||
-- Revision 1.2 2010/04/23 10:46:35 maverick
|
||||
-- Revision 1.1 2009/06/25 02:47:18 niceguy
|
||||
-- Initial revision
|
||||
|
||||
|
||||
E5-121-TRAPS-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
|
||||
OBJECT-TYPE
|
||||
FROM SNMPv2-SMI
|
||||
DisplayString, ifIndex
|
||||
FROM RFC1213-MIB
|
||||
iesChassisId,iesSlotId
|
||||
FROM E5-121-IESCOMMON-MIB
|
||||
e5x121
|
||||
FROM E5-121-MIB
|
||||
dot1agCfmMdMdLevel, dot1agCfmVlanPrimaryVid, dot1agCfmMepIdentifier
|
||||
FROM IEEE8021-CFMD8-MIB;
|
||||
|
||||
trap OBJECT IDENTIFIER ::= { e5x121 12 }
|
||||
|
||||
----------------------------------------
|
||||
-- trap
|
||||
----------------------------------------
|
||||
|
||||
object OBJECT IDENTIFIER ::= { trap 1 }
|
||||
equipment OBJECT IDENTIFIER ::= { trap 3 }
|
||||
systrap OBJECT IDENTIFIER ::= { trap 4 }
|
||||
voiptrap OBJECT IDENTIFIER ::= { trap 7 }
|
||||
interface OBJECT IDENTIFIER ::= { trap 8 }
|
||||
e5Alarm OBJECT IDENTIFIER ::= { trap 9 }
|
||||
|
||||
--------------------
|
||||
-- object
|
||||
--------------------
|
||||
|
||||
eqptAlarmInputIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The index of alarm input."
|
||||
::= { object 2 }
|
||||
|
||||
eqptAlarmInputName OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The Name of alarm input."
|
||||
::= { object 8 }
|
||||
|
||||
sysMacAntiSpoofOrig OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The Original port of Mac-AntiSpoofing."
|
||||
::= { object 9 }
|
||||
|
||||
sysMacAntiSpoofNew OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The New port of Mac-AntiSpoofing."
|
||||
::= { object 10 }
|
||||
|
||||
sysMacAntiSpoofMAC OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The MAC of Mac-AntiSpoofing."
|
||||
::= { object 11 }
|
||||
|
||||
sysAlarmOrigSeverity OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
critical(1),
|
||||
major(2),
|
||||
minor(3),
|
||||
info(4)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The original severity of alarm."
|
||||
::= { object 12 }
|
||||
|
||||
sysAlarmNewSeverity OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
critical(1),
|
||||
major(2),
|
||||
minor(3),
|
||||
info(4)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The new severity of alarm."
|
||||
::= { object 13 }
|
||||
|
||||
sysAlarmConfId OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The changed severity of alarm condition ID.
|
||||
5000:vdslLine_up
|
||||
5001:vdslLine_down
|
||||
5002:vdsl_tca_lol
|
||||
5003:vdsl_tca_lof
|
||||
5004:vdsl_tca_los
|
||||
5005:vdsl_tca_lop
|
||||
5006:vdsl_tca_es
|
||||
5007:vdsl_tca_ses
|
||||
5008:vdsl_tca_uas
|
||||
5009:xd_xtuc_loftrap
|
||||
5010:xd_xtuc_lostrap
|
||||
5011:xd_xtur_loftrap
|
||||
5012:xd_xtur_lostrap
|
||||
5013:xd_xtur_lprtrap
|
||||
5014:ad_dhcp_rt_full
|
||||
5015:ad_dhcp_dm_conflict
|
||||
5016:ad_dhcp_entry_full
|
||||
5017:ad_dhcp_ip_dup
|
||||
5018:ad_dhcp_mac_dup
|
||||
10000:eqptVol_err
|
||||
10001:eqptEqpttemp_err
|
||||
10002:eqptFan_err
|
||||
10003:eqptHw_rtc_fail
|
||||
10004:eqptHw_mon_fail
|
||||
10005:eqptCold_start
|
||||
10006:eqptWarm_start
|
||||
10007:eqptAlm_input
|
||||
10008:voip_battery_fail
|
||||
10009:voip_clock_fail
|
||||
10010:voip_ringer_fault
|
||||
10011:eqptAlm_input2
|
||||
10012:eqptAlm_input3
|
||||
15000:sysReboot
|
||||
15001:sysAco
|
||||
15002:sysAlm_clear
|
||||
15003:sysLogin_fail
|
||||
15004:sysAnti_spoofing
|
||||
15005:sysAlm_svrty_change
|
||||
15006:sysHost_terminate
|
||||
20000:enetUp
|
||||
20001:enetDown
|
||||
25000:voip_temp_error
|
||||
25001:voip_dc_power_fail
|
||||
25002:voip_ac_power_fail
|
||||
25003:voip_ring_timer_fail
|
||||
25004:voip_ring_rsrce_fail
|
||||
25006:voip_dhcp_clt_fail
|
||||
25007:voip_call_setup_failed
|
||||
25008:voip_call_threshold_violate
|
||||
30000:cfmError
|
||||
"
|
||||
::= { object 14 }
|
||||
|
||||
voipDevId OBJECT-TYPE
|
||||
SYNTAX INTEGER{
|
||||
p1-p24(0)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The device ID of the DUT. 0 means port 1 to 24."
|
||||
::= { object 51 }
|
||||
|
||||
|
||||
voipCount OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The number of ringer fault"
|
||||
::= { object 52 }
|
||||
|
||||
voipPhoneState OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
disable(1),
|
||||
onHook(2),
|
||||
offHook(3),
|
||||
ringing(4),
|
||||
powerCutDown(5),
|
||||
testing(6),
|
||||
fault(7),
|
||||
bad(8),
|
||||
uninitialized(9)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Phone status of the line."
|
||||
::= { object 53 }
|
||||
|
||||
voipBatType OBJECT-TYPE
|
||||
SYNTAX INTEGER{
|
||||
batteryLow(0),
|
||||
batteryHigh(1)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The number of ringer fault"
|
||||
::= { object 54 }
|
||||
|
||||
intfCfmCcmErrorCause OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
noDefect(1),
|
||||
rdiReceived(2),
|
||||
macDownReceivedFromDownMEP(3),
|
||||
lostConnectionToRemoteMEP(4),
|
||||
configurationError(5),
|
||||
maintenanceDomainCrossConnect(6)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { object 55 }
|
||||
|
||||
--------------------
|
||||
-- equipment
|
||||
--------------------
|
||||
|
||||
eqptHWMonitorFailure NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Hardware monitor diagnosis is failed."
|
||||
::= { equipment 1 }
|
||||
|
||||
--------------------
|
||||
-- systrap
|
||||
--------------------
|
||||
|
||||
sysMacAntiSpoofing NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
sysMacAntiSpoofOrig,
|
||||
sysMacAntiSpoofNew,
|
||||
sysMacAntiSpoofMAC
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"MAC Anti-spoofing."
|
||||
::= { systrap 1 }
|
||||
|
||||
sysAlarmCutoffEnable NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Alarm cutoff is activated."
|
||||
::= { systrap 2 }
|
||||
|
||||
sysAlarmClearEnable NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Alarm clear is activated."
|
||||
::= { systrap 3 }
|
||||
|
||||
sysLoginFailure NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"User login is failed."
|
||||
::= { systrap 4 }
|
||||
|
||||
sysAlarmSvrtyChange NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Alarm severity is changed."
|
||||
::= { systrap 5 }
|
||||
|
||||
--------------------
|
||||
-- voip
|
||||
--------------------
|
||||
voipBatteryFail NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
iesChassisId,
|
||||
iesSlotId,
|
||||
voipDevId,
|
||||
voipBatType
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Battery fault trigger."
|
||||
::= { voiptrap 1 }
|
||||
|
||||
voipBatteryClear NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
iesChassisId,
|
||||
iesSlotId,
|
||||
voipDevId,
|
||||
voipBatType
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Battery fault release."
|
||||
::= { voiptrap 2 }
|
||||
|
||||
voipClockFail NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
iesChassisId,
|
||||
iesSlotId,
|
||||
voipDevId
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Clock fault trigger."
|
||||
::= { voiptrap 3 }
|
||||
|
||||
voipClockClear NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
iesChassisId,
|
||||
iesSlotId,
|
||||
voipDevId
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Clock fault release."
|
||||
::= { voiptrap 4 }
|
||||
|
||||
voipRingerFault NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
iesChassisId,
|
||||
iesSlotId,
|
||||
voipCount
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Ringer fault trigger."
|
||||
::= { voiptrap 5 }
|
||||
|
||||
voipRingerClear NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
iesChassisId,
|
||||
iesSlotId,
|
||||
voipCount
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Ringer fault release."
|
||||
::= { voiptrap 6 }
|
||||
|
||||
voipTempError NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
iesChassisId,
|
||||
iesSlotId,
|
||||
ifIndex,
|
||||
voipPhoneState
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Temperature error trigger."
|
||||
::= { voiptrap 7 }
|
||||
|
||||
voipTempClear NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
iesChassisId,
|
||||
iesSlotId,
|
||||
ifIndex,
|
||||
voipPhoneState
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Temperature error release."
|
||||
::= { voiptrap 8 }
|
||||
|
||||
voipDcPowerFail NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
iesChassisId,
|
||||
iesSlotId,
|
||||
ifIndex,
|
||||
voipPhoneState
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"DC power error trigger."
|
||||
::= { voiptrap 9 }
|
||||
|
||||
voipDcPowerClear NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
iesChassisId,
|
||||
iesSlotId,
|
||||
ifIndex,
|
||||
voipPhoneState
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"DC power error release."
|
||||
::= { voiptrap 10 }
|
||||
|
||||
voipAcPowerFail NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
iesChassisId,
|
||||
iesSlotId,
|
||||
ifIndex,
|
||||
voipPhoneState
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"DC power error trigger."
|
||||
::= { voiptrap 11 }
|
||||
|
||||
voipAcPowerClear NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
iesChassisId,
|
||||
iesSlotId,
|
||||
ifIndex,
|
||||
voipPhoneState
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"DC power error release."
|
||||
::= { voiptrap 12 }
|
||||
|
||||
--------------------
|
||||
-- interface
|
||||
--------------------
|
||||
|
||||
cfmCcmError NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
dot1agCfmMdMdLevel,
|
||||
dot1agCfmVlanPrimaryVid,
|
||||
dot1agCfmMepIdentifier,
|
||||
intfCfmCcmErrorCause
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
::= { interface 1 }
|
||||
|
||||
|
||||
--------------------
|
||||
-- e5Alarm
|
||||
--------------------
|
||||
|
||||
e5AlarmTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF E5AlarmEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION "This table holds all the active alarms"
|
||||
::= { e5Alarm 1 }
|
||||
|
||||
|
||||
e5AlarmNotify NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
e5AlarmObjectClass,
|
||||
e5AlarmObjectInstance1,
|
||||
e5AlarmObjectInstance2,
|
||||
e5AlarmObjectInstance3,
|
||||
e5AlarmObjectInstance4,
|
||||
e5AlarmType,
|
||||
e5AlarmSeverity,
|
||||
e5AlarmTimeStamp,
|
||||
e5AlarmServiceAffecting,
|
||||
e5AlarmText,
|
||||
e5AlarmTime
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"E5 device alarm notification."
|
||||
::= { e5Alarm 2 }
|
||||
|
||||
|
||||
e5AlarmEntry OBJECT-TYPE
|
||||
SYNTAX E5AlarmEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION "List of attributes regarding alarm table"
|
||||
INDEX { e5AlarmObjectClass, e5AlarmObjectInstance1, e5AlarmObjectInstance2,
|
||||
e5AlarmObjectInstance3, e5AlarmObjectInstance4,
|
||||
e5AlarmObjectInstance5, e5AlarmObjectInstance6,
|
||||
e5AlarmObjectInstance7, e5AlarmObjectInstance8, e5AlarmType }
|
||||
::= { e5AlarmTable 1 }
|
||||
|
||||
E5AlarmEntry ::= SEQUENCE {
|
||||
e5AlarmObjectClass INTEGER,
|
||||
e5AlarmObjectInstance1 INTEGER,
|
||||
e5AlarmObjectInstance2 INTEGER,
|
||||
e5AlarmObjectInstance3 INTEGER,
|
||||
e5AlarmObjectInstance4 INTEGER,
|
||||
e5AlarmObjectInstance5 INTEGER,
|
||||
e5AlarmObjectInstance6 INTEGER,
|
||||
e5AlarmObjectInstance7 INTEGER,
|
||||
e5AlarmObjectInstance8 INTEGER,
|
||||
e5AlarmType INTEGER,
|
||||
e5AlarmSeverity INTEGER,
|
||||
e5AlarmTimeStamp OCTET STRING,
|
||||
e5AlarmServiceAffecting INTEGER,
|
||||
e5AlarmLocationInfo INTEGER,
|
||||
e5AlarmText OCTET STRING,
|
||||
e5AlarmTime INTEGER,
|
||||
e5AlarmCliObject OCTET STRING,
|
||||
e5AlarmSecObjectClass INTEGER,
|
||||
e5AlarmSecObjectInstance1 INTEGER,
|
||||
e5AlarmSecObjectInstance2 INTEGER,
|
||||
e5AlarmSecObjectInstance3 INTEGER,
|
||||
e5AlarmSecObjectInstance4 INTEGER,
|
||||
e5AlarmSecObjectInstance5 INTEGER,
|
||||
e5AlarmSecObjectInstance6 INTEGER,
|
||||
e5AlarmSecObjectInstance7 INTEGER,
|
||||
e5AlarmSecObjectInstance8 INTEGER
|
||||
}
|
||||
|
||||
e5AlarmObjectClass OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
dsl(1),
|
||||
eqpt(2),
|
||||
sys(3),
|
||||
enet(4),
|
||||
vop(5),
|
||||
intf(6),
|
||||
unknown(7)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Object Class for an alarm"
|
||||
::= { e5AlarmEntry 1 }
|
||||
|
||||
e5AlarmObjectInstance1 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Object instance for an alarm, level 1"
|
||||
::= { e5AlarmEntry 2 }
|
||||
|
||||
e5AlarmObjectInstance2 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Object instance for an alarm, level 2"
|
||||
::= { e5AlarmEntry 3 }
|
||||
|
||||
e5AlarmObjectInstance3 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Object instance for an alarm, level 3"
|
||||
::= { e5AlarmEntry 4 }
|
||||
|
||||
e5AlarmObjectInstance4 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Object instance for an alarm, level 4"
|
||||
::= { e5AlarmEntry 5 }
|
||||
|
||||
e5AlarmObjectInstance5 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Object instance for an alarm, level 5"
|
||||
::= { e5AlarmEntry 6 }
|
||||
|
||||
e5AlarmObjectInstance6 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Object instance for an alarm, level 6"
|
||||
::= { e5AlarmEntry 7 }
|
||||
|
||||
e5AlarmObjectInstance7 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Object instance for an alarm, level 7"
|
||||
::= { e5AlarmEntry 8 }
|
||||
|
||||
e5AlarmObjectInstance8 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Object instance for an alarm, level 8"
|
||||
::= { e5AlarmEntry 9 }
|
||||
|
||||
e5AlarmType OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Unique type for an alarm"
|
||||
::= { e5AlarmEntry 10 }
|
||||
|
||||
e5AlarmSeverity OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
clear(0),
|
||||
critical(1),
|
||||
major(2),
|
||||
minor(3),
|
||||
warning(4),
|
||||
unknown(5)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Severity of the alarm"
|
||||
::= { e5AlarmEntry 11 }
|
||||
|
||||
e5AlarmTimeStamp OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (1..50))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Timestamp indicating the set/clear time of the alarm"
|
||||
::= { e5AlarmEntry 12 }
|
||||
|
||||
e5AlarmServiceAffecting OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
yes(1),
|
||||
no(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Indicated the nature of the alarm i.e. service
|
||||
affecting or not"
|
||||
::= { e5AlarmEntry 13 }
|
||||
|
||||
e5AlarmLocationInfo OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
nearEnd(1)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION ""
|
||||
::= { e5AlarmEntry 14 }
|
||||
|
||||
e5AlarmText OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Alarm description"
|
||||
::= { e5AlarmEntry 15 }
|
||||
|
||||
e5AlarmTime OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "UTC time"
|
||||
::= { e5AlarmEntry 16 }
|
||||
|
||||
e5AlarmCliObject OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "The short CLI name for the object class and instance"
|
||||
::= { e5AlarmEntry 17 }
|
||||
|
||||
e5AlarmSecObjectClass OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Secondary Object Class for an alarm"
|
||||
::= { e5AlarmEntry 18 }
|
||||
|
||||
e5AlarmSecObjectInstance1 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Secondary object instance for an alarm, level 1"
|
||||
::= { e5AlarmEntry 19 }
|
||||
|
||||
e5AlarmSecObjectInstance2 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Secondary object instance for an alarm, level 2"
|
||||
::= { e5AlarmEntry 20 }
|
||||
|
||||
e5AlarmSecObjectInstance3 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Secondary object instance for an alarm, level 3"
|
||||
::= { e5AlarmEntry 21 }
|
||||
|
||||
e5AlarmSecObjectInstance4 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Secondary object instance for an alarm, level 4"
|
||||
::= { e5AlarmEntry 22 }
|
||||
|
||||
e5AlarmSecObjectInstance5 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Secondary object instance for an alarm, level 5"
|
||||
::= { e5AlarmEntry 23 }
|
||||
|
||||
e5AlarmSecObjectInstance6 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Secondary object instance for an alarm, level 6"
|
||||
::= { e5AlarmEntry 24 }
|
||||
|
||||
e5AlarmSecObjectInstance7 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Secondary object instance for an alarm, level 7"
|
||||
::= { e5AlarmEntry 25 }
|
||||
|
||||
e5AlarmSecObjectInstance8 OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Secondary object instance for an alarm, level 8"
|
||||
::= { e5AlarmEntry 26 }
|
||||
|
||||
END
|