CISCOSB-EVENTS-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, OBJECT-TYPE FROM SNMPv2-SMI
|
||||
TEXTUAL-CONVENTION, DisplayString,
|
||||
TruthValue, RowStatus FROM SNMPv2-TC
|
||||
switch001 FROM CISCOSB-MIB
|
||||
Counter FROM RFC1155-SMI
|
||||
InterfaceIndex, InterfaceIndexOrZero FROM IF-MIB
|
||||
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
|
||||
RlSmartPortsMacroNameOrZero FROM CISCOSB-SMARTPORTS-MIB;
|
||||
|
||||
rlEventsMib MODULE-IDENTITY
|
||||
LAST-UPDATED "201009110000Z"
|
||||
ORGANIZATION "Cisco Systems, Inc."
|
||||
|
||||
CONTACT-INFO
|
||||
"Postal: 170 West Tasman Drive
|
||||
San Jose , CA 95134-1706
|
||||
USA
|
||||
|
||||
|
||||
Website: Cisco Small Business Support Community <http://www.cisco.com/go/smallbizsupport>"
|
||||
|
||||
DESCRIPTION
|
||||
"MTS events MIB."
|
||||
REVISION "201009110000Z"
|
||||
DESCRIPTION
|
||||
"Initial revision."
|
||||
::= { switch001 150 }
|
||||
|
||||
--
|
||||
-- rlEvents MIB
|
||||
--
|
||||
|
||||
SmartPortType ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Supported smart port types."
|
||||
SYNTAX INTEGER {
|
||||
unknown(1),
|
||||
default(2),
|
||||
printer(3),
|
||||
desktop(4),
|
||||
guest(5),
|
||||
server(6),
|
||||
host(7),
|
||||
ip-camera(8),
|
||||
ip-phone(9),
|
||||
ip-phone-desktop(10),
|
||||
switch(11),
|
||||
router(12),
|
||||
ap(13)
|
||||
}
|
||||
SmartPortMacroParameterName ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Smart macro parameter name."
|
||||
SYNTAX DisplayString(SIZE(1..32))
|
||||
|
||||
SmartPortMacroParameterValue ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Smart macro parameter value."
|
||||
SYNTAX DisplayString(SIZE(1..80))
|
||||
|
||||
SmartPortMacroType ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Smart macro type - built-in or user-defined."
|
||||
SYNTAX INTEGER {built-in(1), user-defined(2)}
|
||||
|
||||
SmartPortMacroParameterOrder ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Smart macro parameter order."
|
||||
SYNTAX INTEGER {single(1), first(2), middle(3), last(4)}
|
||||
|
||||
rlPortEvents OBJECT IDENTIFIER ::= { rlEventsMib 1}
|
||||
|
||||
rlAutoSmartPortAdminStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
enabled (1),
|
||||
disabled (2),
|
||||
controlled(3)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"disabled - Auto Smart port feature is administratively disabled.
|
||||
enabled - Auto Smart port feature is administratively enabled.
|
||||
controlled - Auto Smart port feature is administratively controlled by VOICE VLAN.
|
||||
"
|
||||
DEFVAL {controlled}
|
||||
::= { rlPortEvents 1 }
|
||||
|
||||
rlAutoSmartPortOperStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
enabled (1),
|
||||
disabled (2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"disabled - Auto Smart port feature is operationally disabled.
|
||||
enabled - Auto Smart port feature is operationally enabled.
|
||||
"
|
||||
DEFVAL {disabled}
|
||||
::= { rlPortEvents 2 }
|
||||
|
||||
rlAutoSmartPortLastVoiceVlanStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
enabled (1),
|
||||
disabled (2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicated last status set by VOICE VLAN feature.
|
||||
If rlAutoSmartPortAdminStatus has 'controlled' value then the value of this object is the same as rlAutoSmartPortOperStatus.
|
||||
|
||||
enabled - Auto Smart port feature should be operationally enabled, if rlAutoSmartPortAdminStatus has 'controlled' value.
|
||||
disabled - Auto Smart port feature should be operationally disabled, if rlAutoSmartPortAdminStatus has 'controlled' value
|
||||
"
|
||||
DEFVAL {disabled}
|
||||
::= { rlPortEvents 3}
|
||||
|
||||
rlAutoSmartPortLastVoiceVlanId OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicated last VOICE VLAN ID set by VOICE VLAN feature."
|
||||
::= { rlPortEvents 4}
|
||||
|
||||
rlAutoSmartPortLearningProtocols OBJECT-TYPE
|
||||
SYNTAX BITS {
|
||||
cdp (0),
|
||||
lldp (1)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"cdp - Information about device type of neighboring devices(s) is learnt
|
||||
via CDP (Cisco Discovery Protocol) advertisements.
|
||||
lldp - Information about device type of neighboring devices(s) is learnt
|
||||
via LLDP (Link Layer Discovery Protocol ) advertisements. "
|
||||
::= { rlPortEvents 5 }
|
||||
|
||||
|
||||
rlAutoSmartPortTypesTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlAutoSmartPortTypesEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table is used to keep all the information related to a specific port type."
|
||||
::= { rlPortEvents 6 }
|
||||
|
||||
rlAutoSmartPortTypesEntry OBJECT-TYPE
|
||||
SYNTAX RlAutoSmartPortTypesEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry (conceptual row) in the rlAutoSmartPortTypesTable."
|
||||
INDEX { rlAutoSmartPortTypesType }
|
||||
::= { rlAutoSmartPortTypesTable 1 }
|
||||
|
||||
RlAutoSmartPortTypesEntry ::= SEQUENCE {
|
||||
rlAutoSmartPortTypesType SmartPortType,
|
||||
rlAutoSmartPortTypeStatus INTEGER,
|
||||
rlAutoSmartPortMacro RlSmartPortsMacroNameOrZero,
|
||||
rlAutoSmartPortTypesRevertToDefaultMacro TruthValue,
|
||||
rlAutoSmartPortTypesRevertToDefaultParams TruthValue,
|
||||
rlAutoSmartPortTypesBuiltinMacro SmartPortMacroType
|
||||
|
||||
|
||||
}
|
||||
|
||||
rlAutoSmartPortTypesType OBJECT-TYPE
|
||||
SYNTAX SmartPortType
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Smart port type."
|
||||
::= { rlAutoSmartPortTypesEntry 1 }
|
||||
|
||||
rlAutoSmartPortTypeStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER { enabled(1), disabled(2), default(3) }
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Smart port type global status. "
|
||||
::= { rlAutoSmartPortTypesEntry 2 }
|
||||
|
||||
rlAutoSmartPortMacro OBJECT-TYPE
|
||||
SYNTAX RlSmartPortsMacroNameOrZero
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Macro to be activated when a port is set to the smart port type indicated
|
||||
by rlAutoSmartPortTypesType. The macro whose name is 'no_'<rlAutoSmartPortMacro>
|
||||
is activated when a port ceases to be of this smart port type. "
|
||||
::= { rlAutoSmartPortTypesEntry 3 }
|
||||
|
||||
|
||||
rlAutoSmartPortTypesRevertToDefaultMacro OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Setting this object will cause the smart port type macro associated with this smart port type
|
||||
to revert to the default macro. "
|
||||
::= { rlAutoSmartPortTypesEntry 4 }
|
||||
|
||||
rlAutoSmartPortTypesRevertToDefaultParams OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Setting this object will cause the default smart port type parameter values associated with the built-in macro
|
||||
of this smart port type to revert to their default values."
|
||||
::= { rlAutoSmartPortTypesEntry 5 }
|
||||
|
||||
rlAutoSmartPortTypesBuiltinMacro OBJECT-TYPE
|
||||
SYNTAX SmartPortMacroType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates whether the macro is built-in or user defined."
|
||||
::= { rlAutoSmartPortTypesEntry 6 }
|
||||
|
||||
|
||||
rlAutoSmartPortMacrosParamTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlAutoSmartPortMacrosParamEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table is used to keep all the default parameter values related to a specific port type."
|
||||
::= { rlPortEvents 7 }
|
||||
|
||||
rlAutoSmartPortMacrosParamEntry OBJECT-TYPE
|
||||
SYNTAX RlAutoSmartPortMacrosParamEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A parameter name & default value pair for a smart port type macro."
|
||||
INDEX { rlAutoSmartPortTypesType, rlAutoSmartPortMacroType, IMPLIED rlAutoSmartPortMacrosParamName }
|
||||
::= { rlAutoSmartPortMacrosParamTable 1 }
|
||||
|
||||
RlAutoSmartPortMacrosParamEntry ::= SEQUENCE {
|
||||
rlAutoSmartPortMacroType SmartPortMacroType,
|
||||
rlAutoSmartPortMacrosParamName SmartPortMacroParameterName,
|
||||
rlAutoSmartPortMacrosParamOrder SmartPortMacroParameterOrder,
|
||||
rlAutoSmartPortMacrosParamValue SmartPortMacroParameterValue
|
||||
|
||||
}
|
||||
|
||||
rlAutoSmartPortMacroType OBJECT-TYPE
|
||||
SYNTAX SmartPortMacroType
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Macro type - built-in or user defined."
|
||||
::= { rlAutoSmartPortMacrosParamEntry 1 }
|
||||
|
||||
rlAutoSmartPortMacrosParamName OBJECT-TYPE
|
||||
SYNTAX SmartPortMacroParameterName
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Name of the parameter to be supplied at smart port macro activation. "
|
||||
::= { rlAutoSmartPortMacrosParamEntry 2 }
|
||||
|
||||
rlAutoSmartPortMacrosParamOrder OBJECT-TYPE
|
||||
SYNTAX SmartPortMacroParameterOrder
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Setting this object to 'first' instructs the system to erase all previous information associated
|
||||
with the rlAutoSmartPortTypesType and rlAutoSmartPortMacroType associated with this conceptual row.
|
||||
Setting this object to 'middle' instructs the system to wait for further parameters.
|
||||
Setting this object to 'last' informs the system that no further parameters will be sent and
|
||||
therefore it can start the macro or builtin parameters change process.
|
||||
Setting this object to 'single' instructs the system to erase all previous information associated
|
||||
with the rlAutoSmartPortTypesType and rlAutoSmartPortMacroType associated with this conceptual row and
|
||||
informs the system that no further parameters will be sent and therefore it can start macro or builtin
|
||||
parameters change process."
|
||||
::= { rlAutoSmartPortMacrosParamEntry 3 }
|
||||
|
||||
|
||||
rlAutoSmartPortMacrosParamValue OBJECT-TYPE
|
||||
SYNTAX SmartPortMacroParameterValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Default value of the parameter to be supplied at smart port macro activation. "
|
||||
::= { rlAutoSmartPortMacrosParamEntry 4 }
|
||||
|
||||
|
||||
|
||||
rlAutoSmartPortPortsTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlAutoSmartPortPortsEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table is used to keep all the auto smart port information related to a specific port."
|
||||
::= { rlPortEvents 8 }
|
||||
|
||||
rlAutoSmartPortPortsEntry OBJECT-TYPE
|
||||
SYNTAX RlAutoSmartPortPortsEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry (conceptual row) in the rlAutoSmartPortPortsTable."
|
||||
INDEX { rlAutoSmartPortPort }
|
||||
::= { rlAutoSmartPortPortsTable 1 }
|
||||
|
||||
RlAutoSmartPortPortsEntry ::= SEQUENCE {
|
||||
rlAutoSmartPortPort InterfaceIndex,
|
||||
rlAutoSmartPortPortStatus INTEGER,
|
||||
rlAutoSmartPortPortType SmartPortType,
|
||||
rlAutoSmartPortPersistency INTEGER,
|
||||
rlAutoSmartPortLearntPortType SmartPortType,
|
||||
rlAutoSmartPortPortAcquiringType INTEGER,
|
||||
rlAutoSmartPortLastActivatedMacro RlSmartPortsMacroNameOrZero,
|
||||
rlAutoSmartPortFailedCommandNumber INTEGER,
|
||||
rlAutoSmartPortSetLearntPortType TruthValue
|
||||
|
||||
|
||||
}
|
||||
|
||||
rlAutoSmartPortPort OBJECT-TYPE
|
||||
SYNTAX InterfaceIndex
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The port to which the smartport information is associated."
|
||||
::= { rlAutoSmartPortPortsEntry 1 }
|
||||
|
||||
rlAutoSmartPortPortStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {enabled(1), disabled(2)}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates whether auto smart port feature is enabled or not on this port."
|
||||
DEFVAL { enabled }
|
||||
::= { rlAutoSmartPortPortsEntry 2 }
|
||||
|
||||
rlAutoSmartPortPortType OBJECT-TYPE
|
||||
SYNTAX SmartPortType
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Smart port type associated with this port. If set by user, the port will retain
|
||||
the smart port type at link down, link not present and reboot events."
|
||||
DEFVAL { default }
|
||||
::= { rlAutoSmartPortPortsEntry 3 }
|
||||
|
||||
|
||||
rlAutoSmartPortPersistency OBJECT-TYPE
|
||||
SYNTAX INTEGER {persistent(1), not-persistent(2)}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"If set to persistent then, if the system concludes, according to
|
||||
the information learnt there is no relevant device connected to the port,
|
||||
the rlAutoSmartPortPortType will not be changed (as if the user set this
|
||||
rlAutoSmartPortPortType himself), except on learning another rlAutoSmartPortPortType."
|
||||
DEFVAL { not-persistent }
|
||||
::= { rlAutoSmartPortPortsEntry 4 }
|
||||
|
||||
|
||||
rlAutoSmartPortLearntPortType OBJECT-TYPE
|
||||
SYNTAX SmartPortType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Smart port type learnt via the learning protocols. This value will
|
||||
be different from rlAutoSmartPortPortType only if rlAutoSmartPortPortType
|
||||
was manually configured (i.e. if the value of
|
||||
rlAutoSmartPortPortAcquiringType is 'configuration'). The value of the object
|
||||
is used to set the value of rlAutoSmartPortPortType
|
||||
if the user removes the configuration."
|
||||
DEFVAL { default }
|
||||
::= { rlAutoSmartPortPortsEntry 5 }
|
||||
|
||||
rlAutoSmartPortPortAcquiringType OBJECT-TYPE
|
||||
SYNTAX INTEGER {default(1), configuration(2), persistency(3), learning(4)}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the way that the value of rlAutoSmartPortPortType was acquired. This object can be
|
||||
set only during configuration download."
|
||||
::= { rlAutoSmartPortPortsEntry 6 }
|
||||
|
||||
rlAutoSmartPortLastActivatedMacro OBJECT-TYPE
|
||||
SYNTAX RlSmartPortsMacroNameOrZero
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates macro name of last activated macro or 'no macro' if no macro was run."
|
||||
::= { rlAutoSmartPortPortsEntry 7 }
|
||||
|
||||
rlAutoSmartPortFailedCommandNumber OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates number of command (starting with 1) that caused the macro
|
||||
failure or 0 if the macro succeeded or no macro was run."
|
||||
::= { rlAutoSmartPortPortsEntry 8 }
|
||||
|
||||
rlAutoSmartPortSetLearntPortType OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Instructs the system to set the port type to the learnt port type."
|
||||
::= { rlAutoSmartPortPortsEntry 9 }
|
||||
|
||||
rlAutoSmartPortParamsTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlAutoSmartPortActionParamsEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table optionally determines the parameter values for the macro that is activated when the smartport type is
|
||||
manually changed for a specific port or trunk via the rlAutoSmartPortPortType object."
|
||||
::= { rlPortEvents 9 }
|
||||
|
||||
rlAutoSmartPortParamsEntry OBJECT-TYPE
|
||||
SYNTAX RlAutoSmartPortActionParamsEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A parameter name & immediate value."
|
||||
INDEX { rlAutoSmartPortIfIndex, IMPLIED rlAutoSmartPortParamName }
|
||||
::= { rlAutoSmartPortParamsTable 1 }
|
||||
|
||||
RlAutoSmartPortActionParamsEntry ::= SEQUENCE {
|
||||
rlAutoSmartPortIfIndex InterfaceIndex,
|
||||
rlAutoSmartPortParamName SmartPortMacroParameterName,
|
||||
rlAutoSmartPortParamOrder SmartPortMacroParameterOrder,
|
||||
rlAutoSmartPortParamValue SmartPortMacroParameterValue
|
||||
|
||||
}
|
||||
|
||||
rlAutoSmartPortIfIndex OBJECT-TYPE
|
||||
SYNTAX InterfaceIndex
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The port or trunk that this entry is associated with. "
|
||||
::= { rlAutoSmartPortParamsEntry 1 }
|
||||
|
||||
rlAutoSmartPortParamName OBJECT-TYPE
|
||||
SYNTAX SmartPortMacroParameterName
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Name of the parameter whose value must be supplied at a smart port macro activation. "
|
||||
::= { rlAutoSmartPortParamsEntry 2 }
|
||||
|
||||
rlAutoSmartPortParamOrder OBJECT-TYPE
|
||||
SYNTAX SmartPortMacroParameterOrder
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Setting this object to 'first' instructs the system to erase all previous information associated
|
||||
with the rlAutoSmartPortTypesType and rlAutoSmartPortMacroType associated with this conceptual row.
|
||||
Setting this object to 'middle' instructs the system to wait for further parameters.
|
||||
Setting this object to 'last' informs the system that no further parameters will be sent and
|
||||
therefore it can start applying the smartport type.
|
||||
Setting this object to 'single' instructs the system to erase all previous information associated
|
||||
with the rlAutoSmartPortTypesType and rlAutoSmartPortMacroType associated with this conceptual row and
|
||||
informs the system that no further parameters will be sent and informs the system that no further parameters will be sent and
|
||||
therefore it can start applying the smartport type."
|
||||
::= { rlAutoSmartPortParamsEntry 3 }
|
||||
|
||||
rlAutoSmartPortParamValue OBJECT-TYPE
|
||||
SYNTAX SmartPortMacroParameterValue
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Value of the parameter whose value must be supplied at a smart port macro activation. "
|
||||
::= { rlAutoSmartPortParamsEntry 4 }
|
||||
|
||||
|
||||
|
||||
rlAutoSmartTrunkRefreshTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlAutoSmartTrunkRefreshEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Setting this object causes running the SmartPort macros of the
|
||||
following types: router, switch and ap. This operation is called the trunk refresh operation."
|
||||
::= { rlPortEvents 10 }
|
||||
|
||||
|
||||
rlAutoSmartTrunkRefreshEntry OBJECT-TYPE
|
||||
SYNTAX RlAutoSmartTrunkRefreshEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry (conceptual row) in the rlAutoSmartTrunkRefreshTable."
|
||||
INDEX { rlAutoSmartTrunkRefreshSmartPortType, rlAutoSmartTrunkRefreshIfIndex }
|
||||
::= { rlAutoSmartTrunkRefreshTable 1 }
|
||||
|
||||
RlAutoSmartTrunkRefreshEntry ::= SEQUENCE {
|
||||
rlAutoSmartTrunkRefreshSmartPortType INTEGER,
|
||||
rlAutoSmartTrunkRefreshIfIndex InterfaceIndexOrZero,
|
||||
rlAutoSmartTrunkRefreshRowStatus RowStatus
|
||||
}
|
||||
|
||||
rlAutoSmartTrunkRefreshSmartPortType OBJECT-TYPE
|
||||
SYNTAX INTEGER {default(1), switch(11), router(12), ap(13)}
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"If not default the trunk refresh operation will be carried out on all ports of this smart port type if
|
||||
rlAutoSmartTrunkRefreshIfIndex is nonzero, or on the port specifed by rlAutoSmartTrunkRefreshIfIndex if it's type
|
||||
matches the given this smart port type (if not matching a wrong-value error will be return).
|
||||
If default the trunk refresh operation will be carried out on all ports of router, switch and ap smart port type if
|
||||
rlAutoSmartTrunkRefreshIfIndex is nonzero, or on the port specifed by rlAutoSmartTrunkRefreshIfIndex."
|
||||
::= { rlAutoSmartTrunkRefreshEntry 1 }
|
||||
|
||||
rlAutoSmartTrunkRefreshIfIndex OBJECT-TYPE
|
||||
SYNTAX InterfaceIndexOrZero
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"If 0 the trunk refresh operation will be carried out on all ports of the smart port type as specified in the
|
||||
rlAutoSmartTrunkRefreshSmartPortType. If nonzero the trunk refresh operation will be carried out
|
||||
on the specified port, if rlAutoSmartTrunkRefreshSmartPortType is default or matches the smart port type of
|
||||
the specified port. Any other case will result in a wrong-value error."
|
||||
::= { rlAutoSmartTrunkRefreshEntry 2 }
|
||||
|
||||
rlAutoSmartTrunkRefreshRowStatus OBJECT-TYPE
|
||||
SYNTAX RowStatus
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Since this an action table only createAndGo will be accepted and the conceptual row will vanish immediately
|
||||
after the action execution."
|
||||
::= { rlAutoSmartTrunkRefreshEntry 3 }
|
||||
|
||||
|
||||
rlAutoSmartBusy OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"If true indicates that the autosmartports system is temporarily busy performing a multiport
|
||||
operation and therefore can not service management requests for the time-being."
|
||||
::= { rlPortEvents 11 }
|
||||
|
||||
|
||||
|
||||
END
|