CISCOSB-LBD-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
-- Title: CISCOSB LBD Configuration
|
||||
-- Version: 7.45.00.00
|
||||
-- Date: 24-Oct-2007
|
||||
--
|
||||
|
||||
IMPORTS
|
||||
TruthValue,TEXTUAL-CONVENTION FROM SNMPv2-TC
|
||||
MODULE-IDENTITY, OBJECT-TYPE FROM SNMPv2-SMI
|
||||
ifIndex FROM IF-MIB
|
||||
switch001 FROM CISCOSB-MIB;
|
||||
|
||||
|
||||
|
||||
rlLbd MODULE-IDENTITY
|
||||
LAST-UPDATED "200711070001Z"
|
||||
ORGANIZATION "Cisco Systems, Inc."
|
||||
|
||||
CONTACT-INFO
|
||||
"Postal: 170 West Tasman Drive
|
||||
San Jose , CA 95134-1706
|
||||
USA
|
||||
|
||||
|
||||
Website: Cisco Small Business Support Community <http://www.cisco.com/go/smallbizsupport>"
|
||||
DESCRIPTION
|
||||
"The private MIB module definition for Loopback Detection MIB."
|
||||
REVISION "200711070000Z"
|
||||
DESCRIPTION
|
||||
"Initial version of this MIB."
|
||||
::= { switch001 127 }
|
||||
|
||||
|
||||
-------------------------------------------------------------------------------
|
||||
rlLbdEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enable/Disable Loopback Detection in the switch."
|
||||
::= { rlLbd 1 }
|
||||
|
||||
|
||||
-------------------------------------------------------------------------------
|
||||
rlLbdDetectionInterval OBJECT-TYPE
|
||||
SYNTAX INTEGER(5..60)
|
||||
UNITS "seconds"
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The time in seconds that should pass between unicast LBD packets."
|
||||
::= { rlLbd 2 }
|
||||
|
||||
|
||||
-------------------------------------------------------------------------------
|
||||
|
||||
rlLbdMode OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
source-mac-addr (1),
|
||||
base-mac-addr (2),
|
||||
broadcast-mac-addr (3),
|
||||
predefined-multicast-mac-addr (4),
|
||||
user-defined-mac-addr (5)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Loopback detection mode."
|
||||
::= { rlLbd 3 }
|
||||
|
||||
-------------------------------------------------------------------------------
|
||||
|
||||
rlLbdPortTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlLbdPortEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table contains Admin configuration and operational status per port."
|
||||
::= { rlLbd 4 }
|
||||
|
||||
|
||||
rlLbdPortEntry OBJECT-TYPE
|
||||
SYNTAX RlLbdPortEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Each entry represent a port.
|
||||
Per port contains LBD Admin configuration (SET) and status (GET),
|
||||
LBD Operational status and LBD Vlan configuration (SET) and status (GET)."
|
||||
|
||||
INDEX { ifIndex }
|
||||
::= { rlLbdPortTable 1 }
|
||||
|
||||
RlLbdPortEntry ::= SEQUENCE {
|
||||
rlLbdPortAdminStatus INTEGER,
|
||||
rlLbdPortOperStatus INTEGER
|
||||
}
|
||||
|
||||
rlLbdPortAdminStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
enabled (1),
|
||||
disabled (2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enable/Disable Loopback Detection on port"
|
||||
::= { rlLbdPortEntry 1 }
|
||||
|
||||
rlLbdPortOperStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
inactive (1),
|
||||
active (2),
|
||||
loopDetected (3)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates Loopback Detection operational status on port.
|
||||
'inactive' means that the port is not working in loop-detected operational state;
|
||||
'active' means that the port is Up and working in state of loop-detecting;
|
||||
'loop-detected' means that the system has detected loop on the port."
|
||||
DEFVAL { inactive }
|
||||
::= { rlLbdPortEntry 2 }
|
||||
|
||||
|
||||
END
|