Initial commit
This commit is contained in:
400
MIBS/comware/HH3C-RMON-EXT2-MIB
Normal file
400
MIBS/comware/HH3C-RMON-EXT2-MIB
Normal file
@ -0,0 +1,400 @@
|
||||
-- ==================================================================
|
||||
-- Copyright (c) 2004-2013 New H3C Tech. Co., Ltd. All rights reserved.
|
||||
--
|
||||
-- Description: This file describes the private MIB implementation of RMON
|
||||
-- Reference: the content of this file include part description from RFC2819
|
||||
-- Version: V1.0
|
||||
-- History:
|
||||
-- v1.0 The initial version created by chenweifeng, 2012-06-19
|
||||
-- ==================================================================
|
||||
HH3C-RMON-EXT2-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
DisplayString FROM SNMPv2-TC
|
||||
|
||||
OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY,
|
||||
NOTIFICATION-TYPE, Integer32 FROM SNMPv2-SMI
|
||||
|
||||
OwnerString, EntryStatus FROM RMON-MIB
|
||||
|
||||
hh3cCommon FROM HH3C-OID-MIB;
|
||||
-- ==================================================================
|
||||
--
|
||||
-- ======================= definition begin =========================
|
||||
--
|
||||
-- ==================================================================
|
||||
hh3cRmonExt MODULE-IDENTITY
|
||||
LAST-UPDATED "201206190000Z" -- June 19, 2012 at 16:05 GMT
|
||||
ORGANIZATION
|
||||
"New H3C Tech. Co., Ltd."
|
||||
CONTACT-INFO
|
||||
"Platform Team New H3C Tech. Co., Ltd.
|
||||
Hai-Dian District Beijing P.R. China
|
||||
http://www.h3c.com
|
||||
Zip:100085
|
||||
"
|
||||
DESCRIPTION
|
||||
"The private MIB module for managing remote monitoring
|
||||
device implementations."
|
||||
REVISION "201206190000Z" -- June 19, 2012 at 16:06 GMT
|
||||
DESCRIPTION
|
||||
"The initial revision of this MIB module."
|
||||
::= { hh3cCommon 125 }
|
||||
|
||||
hh3cRmonExtAlarmTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF Hh3cRmonExtAlarmEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A list of alarm entries."
|
||||
::= { hh3cRmonExt 1 }
|
||||
|
||||
hh3cRmonExtAlarmEntry OBJECT-TYPE
|
||||
SYNTAX Hh3cRmonExtAlarmEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A list of parameters that set up a periodic checking
|
||||
for alarm conditions. For example, an instance of the
|
||||
alarmValue object might be named alarmValue.8"
|
||||
INDEX { hh3cRmonExtAlarmIndex }
|
||||
::= { hh3cRmonExtAlarmTable 1 }
|
||||
|
||||
Hh3cRmonExtAlarmEntry ::= SEQUENCE {
|
||||
hh3cRmonExtAlarmIndex Integer32,
|
||||
hh3cRmonExtAlarmInterval Integer32,
|
||||
hh3cRmonExtAlarmVariable DisplayString,
|
||||
hh3cRmonExtAlarmSympol DisplayString,
|
||||
hh3cRmonExtAlarmSampleType INTEGER,
|
||||
hh3cRmonExtAlarmValue Integer32,
|
||||
hh3cRmonExtAlarmStartupAlarm INTEGER,
|
||||
hh3cRmonExtAlarmRisingThreshold Integer32,
|
||||
hh3cRmonExtAlarmFallingThreshold Integer32,
|
||||
hh3cRmonExtAlarmRisingEvtIndex Integer32,
|
||||
hh3cRmonExtAlarmFallingEvtIndex Integer32,
|
||||
hh3cRmonExtAlarmStatCycle Integer32,
|
||||
hh3cRmonExtAlarmStatType INTEGER,
|
||||
hh3cRmonExtAlarmOwner OwnerString,
|
||||
hh3cRmonExtAlarmStatus EntryStatus
|
||||
}
|
||||
|
||||
hh3cRmonExtAlarmIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (1..65535)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An index that uniquely identifies an entry in the
|
||||
alarm table. Each such entry defines a
|
||||
diagnostic sample at a particular interval
|
||||
for an object on the device."
|
||||
::= { hh3cRmonExtAlarmEntry 1 }
|
||||
|
||||
hh3cRmonExtAlarmInterval OBJECT-TYPE
|
||||
SYNTAX Integer32 (10..65535)
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The interval in seconds over which the data is
|
||||
sampled and compared with the rising and falling
|
||||
thresholds. When setting this variable, care
|
||||
should be taken in the case of deltaValue
|
||||
sampling - the interval should be set short enough
|
||||
that the sampled variable is very unlikely to
|
||||
increase or decrease by more than 2^31 - 1 during
|
||||
a single sampling interval.
|
||||
|
||||
This object may not be modified if the associated
|
||||
alarmStatus object is equal to valid."
|
||||
DEFVAL { 1800 }
|
||||
::= { hh3cRmonExtAlarmEntry 2 }
|
||||
|
||||
hh3cRmonExtAlarmVariable OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The object identifier of the particular variable to be
|
||||
sampled. Only variables that resolve to an ASN.1 primitive
|
||||
type of INTEGER (INTEGER, Integer32, Unsigned32, Counter32,
|
||||
Counter64, Gauge, or TimeTicks) may be sampled.
|
||||
|
||||
Because SNMP access control is articulated entirely
|
||||
in terms of the contents of MIB views, no access
|
||||
control mechanism exists that can restrict the value of
|
||||
this object to identify only those objects that exist
|
||||
in a particular MIB view. Because there is thus no
|
||||
acceptable means of restricting the read access that
|
||||
could be obtained through the alarm mechanism, the
|
||||
probe must only grant write access to this object in
|
||||
those views that have read access to all objects on
|
||||
the probe.
|
||||
|
||||
During a set operation, if the supplied variable name is
|
||||
not available in the selected MIB view, a badValue error
|
||||
must be returned.
|
||||
|
||||
This object may not be modified if the associated
|
||||
alarmStatus object is equal to valid."
|
||||
::= { hh3cRmonExtAlarmEntry 3 }
|
||||
|
||||
hh3cRmonExtAlarmSympol OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A comment describing this alarm entry.
|
||||
This object may not be modified if the associated
|
||||
alarmStatus object is equal to valid."
|
||||
::= { hh3cRmonExtAlarmEntry 4 }
|
||||
|
||||
hh3cRmonExtAlarmSampleType OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
absoluteValue(1),
|
||||
deltaValue(2),
|
||||
speedValue(3)
|
||||
}
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The method of sampling the selected variable and
|
||||
calculating the value to be compared against the
|
||||
thresholds. If the value of this object is
|
||||
absoluteValue, the value of the selected variable
|
||||
will be compared directly with the thresholds at the
|
||||
end of the sampling interval. If the value of this
|
||||
object is deltaValue, the value of the selected
|
||||
variable at the last sample will be subtracted from
|
||||
the current value, and the difference compared with
|
||||
the thresholds.
|
||||
|
||||
This object may not be modified if the associated
|
||||
alarmStatus object is equal to valid."
|
||||
DEFVAL { absoluteValue }
|
||||
::= { hh3cRmonExtAlarmEntry 5 }
|
||||
|
||||
hh3cRmonExtAlarmValue OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The value of the statistic during the last sampling
|
||||
period. For example, if the sample type is deltaValue,
|
||||
this value will be the difference between the samples
|
||||
at the beginning and end of the period. If the sample
|
||||
type is absoluteValue, this value will be the sampled
|
||||
value at the end of the period.
|
||||
This is the value that is compared with the rising and
|
||||
falling thresholds.
|
||||
|
||||
The value during the current sampling period is not
|
||||
made available until the period is completed and will
|
||||
remain available until the next period completes."
|
||||
::= { hh3cRmonExtAlarmEntry 6 }
|
||||
|
||||
hh3cRmonExtAlarmStartupAlarm OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
risingAlarm(1),
|
||||
fallingAlarm(2),
|
||||
risingOrFallingAlarm(3)
|
||||
}
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The alarm that may be sent when this entry is first
|
||||
set to valid. If the first sample after this entry
|
||||
becomes valid is greater than or equal to the
|
||||
risingThreshold and alarmStartupAlarm is equal to
|
||||
risingAlarm or risingOrFallingAlarm, then a single
|
||||
rising alarm will be generated. If the first sample
|
||||
after this entry becomes valid is less than or equal
|
||||
to the fallingThreshold and alarmStartupAlarm is equal
|
||||
to fallingAlarm or risingOrFallingAlarm, then a
|
||||
single falling alarm will be generated.
|
||||
|
||||
This object may not be modified if the associated
|
||||
alarmStatus object is equal to valid."
|
||||
DEFVAL { risingOrFallingAlarm }
|
||||
::= { hh3cRmonExtAlarmEntry 7 }
|
||||
|
||||
hh3cRmonExtAlarmRisingThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A threshold for the sampled statistic. When the current
|
||||
sampled value is greater than or equal to this threshold,
|
||||
and the value at the last sampling interval was less than
|
||||
this threshold, a single event will be generated.
|
||||
A single event will also be generated if the first
|
||||
sample after this entry becomes valid is greater than or
|
||||
equal to this threshold and the associated
|
||||
alarmStartupAlarm is equal to risingAlarm or
|
||||
risingOrFallingAlarm.
|
||||
|
||||
After a rising event is generated, another such event
|
||||
will not be generated until the sampled value
|
||||
falls below this threshold and reaches the
|
||||
alarmFallingThreshold.
|
||||
|
||||
This object may not be modified if the associated
|
||||
alarmStatus object is equal to valid."
|
||||
DEFVAL { 1 }
|
||||
::= { hh3cRmonExtAlarmEntry 8 }
|
||||
|
||||
hh3cRmonExtAlarmFallingThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A threshold for the sampled statistic. When the current
|
||||
sampled value is less than or equal to this threshold,
|
||||
and the value at the last sampling interval was greater than
|
||||
this threshold, a single event will be generated.
|
||||
A single event will also be generated if the first
|
||||
sample after this entry becomes valid is less than or
|
||||
equal to this threshold and the associated
|
||||
alarmStartupAlarm is equal to fallingAlarm or
|
||||
risingOrFallingAlarm.
|
||||
|
||||
After a falling event is generated, another such event
|
||||
will not be generated until the sampled value
|
||||
rises above this threshold and reaches the
|
||||
alarmRisingThreshold.
|
||||
|
||||
This object may not be modified if the associated
|
||||
alarmStatus object is equal to valid."
|
||||
DEFVAL { 0 }
|
||||
::= { hh3cRmonExtAlarmEntry 9 }
|
||||
|
||||
hh3cRmonExtAlarmRisingEvtIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..65535)
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The index of the eventEntry that is
|
||||
used when a rising threshold is crossed. The
|
||||
eventEntry identified by a particular value of
|
||||
this index is the same as identified by the same value
|
||||
of the eventIndex object. If there is no
|
||||
corresponding entry in the eventTable, then
|
||||
no association exists. In particular, if this value
|
||||
is zero, no associated event will be generated, as
|
||||
zero is not a valid event index.
|
||||
|
||||
This object may not be modified if the associated
|
||||
alarmStatus object is equal to valid."
|
||||
DEFVAL { 0 }
|
||||
::= { hh3cRmonExtAlarmEntry 10 }
|
||||
|
||||
hh3cRmonExtAlarmFallingEvtIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..65535)
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The index of the eventEntry that is
|
||||
used when a falling threshold is crossed. The
|
||||
eventEntry identified by a particular value of
|
||||
this index is the same as identified by the same value
|
||||
of the eventIndex object. If there is no
|
||||
corresponding entry in the eventTable, then
|
||||
no association exists. In particular, if this value
|
||||
is zero, no associated event will be generated, as
|
||||
zero is not a valid event index.
|
||||
|
||||
This object may not be modified if the associated
|
||||
alarmStatus object is equal to valid."
|
||||
DEFVAL { 0 }
|
||||
::= { hh3cRmonExtAlarmEntry 11 }
|
||||
|
||||
hh3cRmonExtAlarmStatCycle OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..4294967)
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The lifetime (in seconds) starts when an alarm entry
|
||||
is set in valid state.
|
||||
|
||||
If the entry has an infinite lifetime, the value of this
|
||||
object MUST be 0. Otherwise the value MUST be greater
|
||||
than the value of hh3cRmonExtAlarmInterval.
|
||||
|
||||
This object may not be modified if the associated
|
||||
alarmStatus object is equal to valid."
|
||||
DEFVAL { 0 }
|
||||
::= { hh3cRmonExtAlarmEntry 12 }
|
||||
|
||||
hh3cRmonExtAlarmStatType OBJECT-TYPE
|
||||
SYNTAX INTEGER{
|
||||
forever(1),
|
||||
during(2)
|
||||
}
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates whether the entry has an
|
||||
infinite or limited lifetime.
|
||||
|
||||
This object may not be modified if the associated
|
||||
alarmStatus object is equal to valid."
|
||||
DEFVAL { forever }
|
||||
::= { hh3cRmonExtAlarmEntry 13 }
|
||||
|
||||
hh3cRmonExtAlarmOwner OBJECT-TYPE
|
||||
SYNTAX OwnerString
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The entity that configured this entry and is therefore
|
||||
using the resources assigned to it.
|
||||
|
||||
The defalut value of this object is zero length string."
|
||||
::= { hh3cRmonExtAlarmEntry 14 }
|
||||
|
||||
hh3cRmonExtAlarmStatus OBJECT-TYPE
|
||||
SYNTAX EntryStatus
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The status of this alarm entry."
|
||||
::= { hh3cRmonExtAlarmEntry 15 }
|
||||
|
||||
-- extend from Remote Network Monitoring Traps
|
||||
|
||||
hh3cRmonExtEvent OBJECT-IDENTITY
|
||||
STATUS current
|
||||
DESCRIPTION "Definition point for notifications."
|
||||
::= { hh3cRmonExt 0 }
|
||||
|
||||
hh3cRmonExtRisingAlarm NOTIFICATION-TYPE
|
||||
OBJECTS{
|
||||
hh3cRmonExtAlarmIndex,
|
||||
hh3cRmonExtAlarmSympol,
|
||||
hh3cRmonExtAlarmSampleType,
|
||||
hh3cRmonExtAlarmValue,
|
||||
hh3cRmonExtAlarmRisingThreshold
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The SNMP trap that is generated when an alarm
|
||||
entry crosses its rising threshold and generates
|
||||
an event that is configured for sending SNMP
|
||||
traps."
|
||||
::= { hh3cRmonExtEvent 1 }
|
||||
|
||||
hh3cRmonExtFallingAlarm NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
hh3cRmonExtAlarmIndex,
|
||||
hh3cRmonExtAlarmSympol,
|
||||
hh3cRmonExtAlarmSampleType,
|
||||
hh3cRmonExtAlarmValue,
|
||||
hh3cRmonExtAlarmFallingThreshold
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The SNMP trap that is generated when an alarm
|
||||
entry crosses its falling threshold and generates
|
||||
an event that is configured for sending SNMP
|
||||
traps."
|
||||
::= { hh3cRmonExtEvent 2 }
|
||||
|
||||
END
|