Initial commit
This commit is contained in:
		
							
								
								
									
										909
									
								
								MIBS/dasan/SLE-MPLS-TP-TUNNEL-MIB
									
									
									
									
									
										Normal file
									
								
							
							
						
						
									
										909
									
								
								MIBS/dasan/SLE-MPLS-TP-TUNNEL-MIB
									
									
									
									
									
										Normal file
									
								
							@@ -0,0 +1,909 @@
 | 
			
		||||
--
 | 
			
		||||
-- sle-mpls-tp-tunnel-mib.mib
 | 
			
		||||
-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0  Build 88
 | 
			
		||||
-- Friday, January 15, 2016 at 13:52:12
 | 
			
		||||
--
 | 
			
		||||
 | 
			
		||||
	SLE-MPLS-TP-TUNNEL-MIB DEFINITIONS ::= BEGIN
 | 
			
		||||
 
 | 
			
		||||
		IMPORTS
 | 
			
		||||
			sleMgmt			
 | 
			
		||||
				FROM DASAN-SMI			
 | 
			
		||||
			ifGeneralInformationGroup, ifCounterDiscontinuityGroup, InterfaceIndexOrZero			
 | 
			
		||||
				FROM IF-MIB			
 | 
			
		||||
			MplsCcId, MplsIccId			
 | 
			
		||||
				FROM MPLS-TC-EXT-STD-MIB			
 | 
			
		||||
			mplsStdMIB, MplsLabel			
 | 
			
		||||
				FROM MPLS-TC-STD-MIB			
 | 
			
		||||
			SleControlStatusType, SleControlRequestResultType			
 | 
			
		||||
				FROM SLE-TC-MIB			
 | 
			
		||||
			zeroDotZero, TimeTicks, IpAddress, Unsigned32, Gauge32, 
 | 
			
		||||
			OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY			
 | 
			
		||||
				FROM SNMPv2-SMI			
 | 
			
		||||
			MacAddress			
 | 
			
		||||
				FROM SNMPv2-TC;
 | 
			
		||||
	
 | 
			
		||||
	
 | 
			
		||||
		sleMplsTpTunnel MODULE-IDENTITY 
 | 
			
		||||
			LAST-UPDATED "201510070000Z"		-- October 07, 2015 at 00:00 GMT
 | 
			
		||||
			ORGANIZATION 
 | 
			
		||||
				"Multiprotocol Label Switching (MPLS) Working Group"
 | 
			
		||||
			CONTACT-INFO 
 | 
			
		||||
				"Gyerok Kwon 
 | 
			
		||||
				Dasan Networks
 | 
			
		||||
				Email:  grkwon@dasannetworks.com
 | 
			
		||||
				
 | 
			
		||||
				Kantharaj B M
 | 
			
		||||
				Dasan Networks
 | 
			
		||||
				Email:  kanth@dasannetworks.com
 | 
			
		||||
				
 | 
			
		||||
				DongChel Shin (Chris)
 | 
			
		||||
				Dasan Networks
 | 
			
		||||
				Email:  dchshin@dasannetworks.com
 | 
			
		||||
				
 | 
			
		||||
				Comments about this document should be emailed
 | 
			
		||||
				directly to the Dasan support email ID at
 | 
			
		||||
				support@dasannetworks.com."
 | 
			
		||||
			DESCRIPTION 
 | 
			
		||||
				"Copyright (C) The Internet Society (2004). The
 | 
			
		||||
				initial version of this MIB module was published
 | 
			
		||||
				in RFC 3812. For full legal notices see the RFC
 | 
			
		||||
				itself or see: http://www.ietf.org/copyrights/ianamib.html
 | 
			
		||||
				
 | 
			
		||||
				This MIB module contains managed object definitions
 | 
			
		||||
				 for MPLS Traffic Engineering (TE) as defined in:
 | 
			
		||||
				1. Extensions to RSVP for LSP Tunnels, Awduche et
 | 
			
		||||
				 al, RFC 3209, December 2001
 | 
			
		||||
				2. Constraint-Based LSP Setup using LDP, Jamoussi
 | 
			
		||||
				
 | 
			
		||||
				 (Editor), RFC 3212, January 2002
 | 
			
		||||
				3. Requirements for Traffic Engineering Over MPLS,
 | 
			
		||||
				 Awduche, D., Malcolm, J., Agogbua, J., O'Dell, M.,
 | 
			
		||||
				 and J. McManus, [RFC2702], September 1999"
 | 
			
		||||
			REVISION "200406030000Z"		-- June 03, 2004 at 00:00 GMT
 | 
			
		||||
			DESCRIPTION 
 | 
			
		||||
				"Initial version issued as part of RFC 3812."
 | 
			
		||||
			::= { sleMpls 14 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
	
 | 
			
		||||
	
 | 
			
		||||
--
 | 
			
		||||
-- Node definitions
 | 
			
		||||
--
 | 
			
		||||
	
 | 
			
		||||
		sleMpls OBJECT-IDENTITY
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION 
 | 
			
		||||
				"SLE MPLS."
 | 
			
		||||
			::= { sleMgmt 16 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfg OBJECT IDENTIFIER ::= { sleMplsTpTunnel 1 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoTable OBJECT-TYPE
 | 
			
		||||
			SYNTAX SEQUENCE OF SleMplsTpTunnelCfgInfoEntry
 | 
			
		||||
			MAX-ACCESS not-accessible
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"The mplsTunnelTable allows new MPLS tunnels to be
 | 
			
		||||
				created between an LSR and a remote endpoint, and
 | 
			
		||||
				existing tunnels to be reconfigured or removed.
 | 
			
		||||
				Note that only point-to-point tunnel segments are
 | 
			
		||||
				supported, although multipoint-to-point and point-
 | 
			
		||||
				to-multipoint connections are supported by an LSR
 | 
			
		||||
				acting as a cross-connect.  Each MPLS tunnel can
 | 
			
		||||
				thus have one out-segment originating at this LSR
 | 
			
		||||
				and/or one in-segment terminating at this LSR."
 | 
			
		||||
			::= { sleMplsTpTunnelCfg 1 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoEntry OBJECT-TYPE
 | 
			
		||||
			SYNTAX SleMplsTpTunnelCfgInfoEntry
 | 
			
		||||
			MAX-ACCESS not-accessible
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"An entry in this table represents an MPLS tunnel.
 | 
			
		||||
				An entry can be created by a network administrator
 | 
			
		||||
				or by an SNMP agent as instructed by an MPLS
 | 
			
		||||
				signalling protocol. Whenever a new entry is
 | 
			
		||||
				created with mplsTunnelIsIf set to true(1), then a
 | 
			
		||||
				corresponding entry is created in ifTable as well
 | 
			
		||||
				(see RFC 2863). The ifType of this entry is
 | 
			
		||||
				mplsTunnel(150).
 | 
			
		||||
				
 | 
			
		||||
				A tunnel entry needs to be uniquely identified across
 | 
			
		||||
				a MPLS network. Indices mplsTunnelIndex and
 | 
			
		||||
				mplsTunnelInstance uniquely identify a tunnel on
 | 
			
		||||
				the LSR originating the tunnel.  To uniquely
 | 
			
		||||
				identify a tunnel across an MPLS network requires
 | 
			
		||||
				
 | 
			
		||||
				index mplsTunnelIngressLSRId.  The last index
 | 
			
		||||
				mplsTunnelEgressLSRId is useful in identifying all
 | 
			
		||||
				instances of a tunnel that terminate on the same
 | 
			
		||||
				egress LSR."
 | 
			
		||||
			REFERENCE
 | 
			
		||||
				"1. RFC 2863 - The Interfaces Group MIB, McCloghrie,
 | 
			
		||||
				K., and F. Kastenholtz, June 2000 "
 | 
			
		||||
			INDEX { sleMplsTpTunnelCfgInfoIndex }
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoTable 1 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		SleMplsTpTunnelCfgInfoEntry ::=
 | 
			
		||||
			SEQUENCE { 
 | 
			
		||||
				sleMplsTpTunnelCfgInfoIndex
 | 
			
		||||
					Unsigned32,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoName
 | 
			
		||||
					OCTET STRING,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoId
 | 
			
		||||
					Unsigned32,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoSrcIdType
 | 
			
		||||
					INTEGER,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoSrcGId
 | 
			
		||||
					Unsigned32,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoSrcCc
 | 
			
		||||
					MplsCcId,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoSrcIcc
 | 
			
		||||
					MplsIccId,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoSrcNodeId
 | 
			
		||||
					IpAddress,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoDestIdType
 | 
			
		||||
					INTEGER,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoDestGId
 | 
			
		||||
					Unsigned32,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoDestCc
 | 
			
		||||
					MplsCcId,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoDestIcc
 | 
			
		||||
					MplsIccId,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoDestNodeId
 | 
			
		||||
					IpAddress,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoMode
 | 
			
		||||
					INTEGER,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoFwdInLabel
 | 
			
		||||
					MplsLabel,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoFwdInIfIndex
 | 
			
		||||
					InterfaceIndexOrZero,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoFwdOperation
 | 
			
		||||
					INTEGER,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoFwdOutLabel
 | 
			
		||||
					MplsLabel,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoFwdOutIfIndex
 | 
			
		||||
					InterfaceIndexOrZero,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoFwdOutMac
 | 
			
		||||
					MacAddress,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoRevInLabel
 | 
			
		||||
					MplsLabel,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoRevInIfIndex
 | 
			
		||||
					InterfaceIndexOrZero,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoRevOperation
 | 
			
		||||
					INTEGER,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoRevOutLabel
 | 
			
		||||
					MplsLabel,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoRevOutIfIndex
 | 
			
		||||
					InterfaceIndexOrZero,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoRevOutMac
 | 
			
		||||
					MacAddress,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoState
 | 
			
		||||
					INTEGER,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoRole
 | 
			
		||||
					INTEGER,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoAssociateTnlName
 | 
			
		||||
					OCTET STRING,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoDescription
 | 
			
		||||
					OCTET STRING,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoHlspRole
 | 
			
		||||
					INTEGER,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoHlspServerTunnelName
 | 
			
		||||
					OCTET STRING,
 | 
			
		||||
				sleMplsTpTunnelCfgInfoQosPolicyName
 | 
			
		||||
					OCTET STRING
 | 
			
		||||
			 }
 | 
			
		||||
 | 
			
		||||
		sleMplsTpTunnelCfgInfoIndex OBJECT-TYPE
 | 
			
		||||
			SYNTAX Unsigned32 (0..65535)
 | 
			
		||||
			MAX-ACCESS not-accessible
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"A unique value which identify an entry in this table."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 1 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoName OBJECT-TYPE
 | 
			
		||||
			SYNTAX OCTET STRING (SIZE (0..16))
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"The canonical name assigned to the tunnel. This name
 | 
			
		||||
				can be used to refer to the tunnel on the LSR's
 | 
			
		||||
				console port.  If mplsTunnelIsIf is set to true
 | 
			
		||||
				then the ifName of the interface corresponding to
 | 
			
		||||
				this tunnel should have a value equal to
 | 
			
		||||
				mplsTunnelName.  Also see the description of ifName
 | 
			
		||||
				in RFC 2863."
 | 
			
		||||
			REFERENCE
 | 
			
		||||
				"RFC 2863 - The Interfaces Group MIB, McCloghrie, K.,
 | 
			
		||||
				and F. Kastenholtz, June 2000."
 | 
			
		||||
			DEFVAL { "" }
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 2 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoId OBJECT-TYPE
 | 
			
		||||
			SYNTAX Unsigned32 (1..65535)
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"Uniquely identifies a set of tunnel instances
 | 
			
		||||
				between a pair of ingress and egress LSRs.
 | 
			
		||||
				Managers should obtain new values for row
 | 
			
		||||
				creation in this table by reading
 | 
			
		||||
				mplsTunnelIndexNext. When
 | 
			
		||||
				the MPLS signalling protocol is rsvp(2) this value
 | 
			
		||||
				SHOULD be equal to the value signaled in the
 | 
			
		||||
				Tunnel Id of the Session object. When the MPLS
 | 
			
		||||
				signalling protocol is crldp(3) this value
 | 
			
		||||
				SHOULD be equal to the value signaled in the
 | 
			
		||||
				LSP ID."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 3 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoSrcIdType OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				ietf(1),
 | 
			
		||||
				itut(2)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the ietf or itut type."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 4 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoSrcGId OBJECT-TYPE
 | 
			
		||||
			SYNTAX Unsigned32 (1..4294967295)
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This Object is used to display the GlobalID of IETF"
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 5 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoSrcCc OBJECT-TYPE
 | 
			
		||||
			SYNTAX MplsCcId
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This Object is used to display the Source CC-ID of ITUT"
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 6 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoSrcIcc OBJECT-TYPE
 | 
			
		||||
			SYNTAX MplsIccId
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This Object is used to set the Source ICC-ID of ITUT"
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 7 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoSrcNodeId OBJECT-TYPE
 | 
			
		||||
			SYNTAX IpAddress
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This Object is used to display the Source Node ID of IETF and ITUT"
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 8 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoDestIdType OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				ietf(1),
 | 
			
		||||
				itut(2)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the ietf or itut type."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 9 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoDestGId OBJECT-TYPE
 | 
			
		||||
			SYNTAX Unsigned32 (1..4294967295)
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This Object is used to set the Destination GlobalID of IETF"
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 10 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoDestCc OBJECT-TYPE
 | 
			
		||||
			SYNTAX MplsCcId
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This Object is used to display the Destination CC-ID of ITUT"
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 11 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoDestIcc OBJECT-TYPE
 | 
			
		||||
			SYNTAX MplsIccId
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This Object is used to set the Destination ICC-ID of ITUT"
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 12 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoDestNodeId OBJECT-TYPE
 | 
			
		||||
			SYNTAX IpAddress
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This Object is used to display the Destination Node ID of IETF and ITUT"
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 13 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoMode OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				none(0),
 | 
			
		||||
				unidirectional(1),
 | 
			
		||||
				bidirectional(2),
 | 
			
		||||
				corouted(3),
 | 
			
		||||
				associate(4)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the Tunnel Mode"
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 14 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoFwdInLabel OBJECT-TYPE
 | 
			
		||||
			SYNTAX MplsLabel
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to display the Forward In Label.
 | 
			
		||||
				The lable range is 0 to 1048575. Here 0 to 15 are
 | 
			
		||||
				reserved labels. User allowed range is 16 to 1048575..
 | 
			
		||||
				
 | 
			
		||||
				The default value 1048576 is invalid label "
 | 
			
		||||
			DEFVAL { 1048576 }
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 15 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoFwdInIfIndex OBJECT-TYPE
 | 
			
		||||
			SYNTAX InterfaceIndexOrZero
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the Forward IN Interface index "
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 16 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoFwdOperation OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				none(0),
 | 
			
		||||
				push(1),
 | 
			
		||||
				pop(2),
 | 
			
		||||
				swap(3)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the Forward Ilm OPeration ."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 17 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoFwdOutLabel OBJECT-TYPE
 | 
			
		||||
			SYNTAX MplsLabel
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to display the Forward In Label.
 | 
			
		||||
				The lable range is 0 to 1048575. Here 0 to 15 are
 | 
			
		||||
				reserved labels. User allowed range is 16 to 1048575.
 | 
			
		||||
				
 | 
			
		||||
				The default value 1048576 is invalid label "
 | 
			
		||||
			DEFVAL { 1048576 }
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 18 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoFwdOutIfIndex OBJECT-TYPE
 | 
			
		||||
			SYNTAX InterfaceIndexOrZero
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the Forward OUT Interface index "
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 19 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoFwdOutMac OBJECT-TYPE
 | 
			
		||||
			SYNTAX MacAddress
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to display the Forward OUT MAC ADDRESS "
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 20 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoRevInLabel OBJECT-TYPE
 | 
			
		||||
			SYNTAX MplsLabel
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to display the Forward In Label.
 | 
			
		||||
				The lable range is 0 to 1048575. Here 0 to 15 are
 | 
			
		||||
				reserved labels. User allowed range is 16 to 1048575.
 | 
			
		||||
				
 | 
			
		||||
				The default value 1048576 is invalid label "
 | 
			
		||||
			DEFVAL { 1048576 }
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 21 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoRevInIfIndex OBJECT-TYPE
 | 
			
		||||
			SYNTAX InterfaceIndexOrZero
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the Reverse IN Interface index "
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 22 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoRevOperation OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				none(0),
 | 
			
		||||
				push(1),
 | 
			
		||||
				pop(2),
 | 
			
		||||
				swap(3)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the Reverse Ilm OPeration ."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 23 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoRevOutLabel OBJECT-TYPE
 | 
			
		||||
			SYNTAX MplsLabel
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to display the Forward In Label.
 | 
			
		||||
				The lable range is 0 to 1048575. Here 0 to 15 are
 | 
			
		||||
				reserved labels. User allowed range is 16 to 1048575.
 | 
			
		||||
				
 | 
			
		||||
				The default value 1048576 is invalid label "
 | 
			
		||||
			DEFVAL { 1048576 }
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 24 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoRevOutIfIndex OBJECT-TYPE
 | 
			
		||||
			SYNTAX InterfaceIndexOrZero
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the Reverse OUT Interface index "
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 25 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoRevOutMac OBJECT-TYPE
 | 
			
		||||
			SYNTAX MacAddress
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to display the Forward OUT MAC ADDRESS ."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 26 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoState OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				up(1),
 | 
			
		||||
				down(2)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is to display status of the tunnel."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 27 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoRole OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				source(0),
 | 
			
		||||
				transist(1),
 | 
			
		||||
				destination(2)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is to display Role  of the tunnel."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 28 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoAssociateTnlName OBJECT-TYPE
 | 
			
		||||
			SYNTAX OCTET STRING
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object to display associate of reverse tunnel."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 29 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoDescription OBJECT-TYPE
 | 
			
		||||
			SYNTAX OCTET STRING
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"Description."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 30 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoHlspRole OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				server(1),
 | 
			
		||||
				client(2)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This  object is used to set the Hlsp Tunnel. whether the tunnel is Server or client.
 | 
			
		||||
				server (1) :- To set the  Server Tunnel
 | 
			
		||||
				client(2) :- To set the  Client Tunnel ."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 31 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoHlspServerTunnelName OBJECT-TYPE
 | 
			
		||||
			SYNTAX OCTET STRING
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the server TunnelName, 
 | 
			
		||||
				when sleMplsTpTunnelCfgControlHlspOption as a client ."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 32 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgInfoQosPolicyName OBJECT-TYPE
 | 
			
		||||
			SYNTAX OCTET STRING
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the Qos Policy name."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgInfoEntry 33 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControl OBJECT IDENTIFIER ::= { sleMplsTpTunnelCfg 2 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlRequest OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				createMplsTpTunnelEntry(1),
 | 
			
		||||
				deleteMplsTpTunnelEntry(2),
 | 
			
		||||
				setMplsTpTunnelMode(3),
 | 
			
		||||
				setNhlfe(4),
 | 
			
		||||
				setIlmPop(5),
 | 
			
		||||
				setIlmSwap(6),
 | 
			
		||||
				setAssociateTunnel(7),
 | 
			
		||||
				unsetNhlfe(8),
 | 
			
		||||
				unsetIlmPop(9),
 | 
			
		||||
				unsetIlmSwap(10),
 | 
			
		||||
				unsetAssociateTunnel(11),
 | 
			
		||||
				setDescription(12),
 | 
			
		||||
				setHlspServerLsp(13),
 | 
			
		||||
				setHlspClientLsp(14),
 | 
			
		||||
				unsetHlspServerLsp(15),
 | 
			
		||||
				unsetHlspClientLsp(16),
 | 
			
		||||
				setTunnelQosPolicyName(17),
 | 
			
		||||
				unsetTunnelQosPolicyName(18)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object holds the possible read-write columns that can be
 | 
			
		||||
				modified in the Tunnel table. For each read-write column of 
 | 
			
		||||
				Tunnel table, a Set Operation controlvalue is added in this object."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 1 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlStatus OBJECT-TYPE
 | 
			
		||||
			SYNTAX SleControlStatusType
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object displays the status of the configuration done."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 2 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlTimer OBJECT-TYPE
 | 
			
		||||
			SYNTAX Gauge32
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is based on the SLE style where a timer is configured 
 | 
			
		||||
				for every control table."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 3 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlTimeStamp OBJECT-TYPE
 | 
			
		||||
			SYNTAX TimeTicks
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object specifies the time at which the configuration is done."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 4 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlReqResult OBJECT-TYPE
 | 
			
		||||
			SYNTAX SleControlRequestResultType
 | 
			
		||||
			MAX-ACCESS read-only
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"The standard result of the SET operation is stored here."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 5 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlName OBJECT-TYPE
 | 
			
		||||
			SYNTAX OCTET STRING (SIZE (0..16))
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"The canonical name assigned to the tunnel. This name
 | 
			
		||||
				can be used to refer to the tunnel on the LSR's
 | 
			
		||||
				console port.  If mplsTunnelIsIf is set to true
 | 
			
		||||
				then the ifName of the interface corresponding to
 | 
			
		||||
				this tunnel should have a value equal to
 | 
			
		||||
				SlemplsTunnelName.  Also see the description of ifName
 | 
			
		||||
				in RFC 2863."
 | 
			
		||||
			REFERENCE
 | 
			
		||||
				"RFC 2863 - The Interfaces Group MIB, McCloghrie, K.,
 | 
			
		||||
				and F. Kastenholtz, June 2000."
 | 
			
		||||
			DEFVAL { "" }
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 6 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlId OBJECT-TYPE
 | 
			
		||||
			SYNTAX Unsigned32 (1..65535)
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the tunnel Id ."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 7 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlSrcIdType OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				ietf(1),
 | 
			
		||||
				itut(2)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the ietf or itut type."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 8 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlSrcGId OBJECT-TYPE
 | 
			
		||||
			SYNTAX Unsigned32 (1..4294967295)
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the source Global-Id for IETF ."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 9 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlSrcCc OBJECT-TYPE
 | 
			
		||||
			SYNTAX MplsCcId
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the source CC-ID for ITUT."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 10 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlSrcIcc OBJECT-TYPE
 | 
			
		||||
			SYNTAX MplsIccId
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the Source ICC-ID for ITUT."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 11 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlSrcNodeId OBJECT-TYPE
 | 
			
		||||
			SYNTAX IpAddress
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the Source Node-Id for IETF and ITUT"
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 12 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlDestIdType OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				ietf(1),
 | 
			
		||||
				itut(2)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the ietf or itut type."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 13 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlDestGId OBJECT-TYPE
 | 
			
		||||
			SYNTAX Unsigned32 (1)
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the Destination Global-Id for IETF ."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 14 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlDestCc OBJECT-TYPE
 | 
			
		||||
			SYNTAX MplsCcId
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the Destination CC-ID for ITUT."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 15 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlDestIcc OBJECT-TYPE
 | 
			
		||||
			SYNTAX MplsIccId
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the Destination ICC-ID for ITUT."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 16 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlDestNodeId OBJECT-TYPE
 | 
			
		||||
			SYNTAX IpAddress
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This  object is used to set the Destination NodeID for IETF 
 | 
			
		||||
				and ITUT."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 17 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlMode OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				unidirectional(1),
 | 
			
		||||
				bidirectional(2)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This  object is used to set the Tunnel mode ."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 18 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlPath OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				forwardPath(1),
 | 
			
		||||
				reversePath(2)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to Set the forward path and reverse path 
 | 
			
		||||
				tunnel."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 19 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlInLabel OBJECT-TYPE
 | 
			
		||||
			SYNTAX MplsLabel
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the Inlabel. "
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 20 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlInInterface OBJECT-TYPE
 | 
			
		||||
			SYNTAX InterfaceIndexOrZero
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the Ininterface index."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 21 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlOperation OBJECT-TYPE
 | 
			
		||||
			SYNTAX INTEGER
 | 
			
		||||
				{
 | 
			
		||||
				push(1),
 | 
			
		||||
				pop(2),
 | 
			
		||||
				swap(3)
 | 
			
		||||
				}
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the operation of Tuunel "
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 22 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlOutLabel OBJECT-TYPE
 | 
			
		||||
			SYNTAX MplsLabel
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the outlabel. "
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 23 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlOutInterface OBJECT-TYPE
 | 
			
		||||
			SYNTAX InterfaceIndexOrZero
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the outerinterface index."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 24 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlOutMacAddress OBJECT-TYPE
 | 
			
		||||
			SYNTAX MacAddress
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to Set the Out MacAddress ."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 25 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlAssociateTnlName OBJECT-TYPE
 | 
			
		||||
			SYNTAX OCTET STRING
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to Associated Forward tunnel and reverse tunnel
 | 
			
		||||
				with reverse tunnel name ."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 26 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlDescription OBJECT-TYPE
 | 
			
		||||
			SYNTAX OCTET STRING
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"Description."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 27 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlHlspSeverTunnelName OBJECT-TYPE
 | 
			
		||||
			SYNTAX OCTET STRING
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the server Tunnel name for associating server and client."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 28 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
		sleMplsTpTunnelCfgControlQosPolicyName OBJECT-TYPE
 | 
			
		||||
			SYNTAX OCTET STRING
 | 
			
		||||
			MAX-ACCESS read-write
 | 
			
		||||
			STATUS current
 | 
			
		||||
			DESCRIPTION
 | 
			
		||||
				"This object is used to set the Qos Policy name."
 | 
			
		||||
			::= { sleMplsTpTunnelCfgControl 29 }
 | 
			
		||||
 | 
			
		||||
		
 | 
			
		||||
	
 | 
			
		||||
	END
 | 
			
		||||
 | 
			
		||||
--
 | 
			
		||||
-- sle-mpls-tp-tunnel-mib.mib
 | 
			
		||||
--
 | 
			
		||||
		Reference in New Issue
	
	Block a user