-- sle-mpls-tp-tunnel-mib.mib
|
||||
-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
|
||||
-- Friday, January 15, 2016 at 13:52:12
|
||||
--
|
||||
|
||||
SLE-MPLS-TP-TUNNEL-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
sleMgmt
|
||||
FROM DASAN-SMI
|
||||
ifGeneralInformationGroup, ifCounterDiscontinuityGroup, InterfaceIndexOrZero
|
||||
FROM IF-MIB
|
||||
MplsCcId, MplsIccId
|
||||
FROM MPLS-TC-EXT-STD-MIB
|
||||
mplsStdMIB, MplsLabel
|
||||
FROM MPLS-TC-STD-MIB
|
||||
SleControlStatusType, SleControlRequestResultType
|
||||
FROM SLE-TC-MIB
|
||||
zeroDotZero, TimeTicks, IpAddress, Unsigned32, Gauge32,
|
||||
OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY
|
||||
FROM SNMPv2-SMI
|
||||
MacAddress
|
||||
FROM SNMPv2-TC;
|
||||
|
||||
|
||||
sleMplsTpTunnel MODULE-IDENTITY
|
||||
LAST-UPDATED "201510070000Z" -- October 07, 2015 at 00:00 GMT
|
||||
ORGANIZATION
|
||||
"Multiprotocol Label Switching (MPLS) Working Group"
|
||||
CONTACT-INFO
|
||||
"Gyerok Kwon
|
||||
Dasan Networks
|
||||
Email: grkwon@dasannetworks.com
|
||||
|
||||
Kantharaj B M
|
||||
Dasan Networks
|
||||
Email: kanth@dasannetworks.com
|
||||
|
||||
DongChel Shin (Chris)
|
||||
Dasan Networks
|
||||
Email: dchshin@dasannetworks.com
|
||||
|
||||
Comments about this document should be emailed
|
||||
directly to the Dasan support email ID at
|
||||
support@dasannetworks.com."
|
||||
DESCRIPTION
|
||||
"Copyright (C) The Internet Society (2004). The
|
||||
initial version of this MIB module was published
|
||||
in RFC 3812. For full legal notices see the RFC
|
||||
itself or see: http://www.ietf.org/copyrights/ianamib.html
|
||||
|
||||
This MIB module contains managed object definitions
|
||||
for MPLS Traffic Engineering (TE) as defined in:
|
||||
1. Extensions to RSVP for LSP Tunnels, Awduche et
|
||||
al, RFC 3209, December 2001
|
||||
2. Constraint-Based LSP Setup using LDP, Jamoussi
|
||||
|
||||
(Editor), RFC 3212, January 2002
|
||||
3. Requirements for Traffic Engineering Over MPLS,
|
||||
Awduche, D., Malcolm, J., Agogbua, J., O'Dell, M.,
|
||||
and J. McManus, [RFC2702], September 1999"
|
||||
REVISION "200406030000Z" -- June 03, 2004 at 00:00 GMT
|
||||
DESCRIPTION
|
||||
"Initial version issued as part of RFC 3812."
|
||||
::= { sleMpls 14 }
|
||||
|
||||
|
||||
|
||||
|
||||
--
|
||||
-- Node definitions
|
||||
--
|
||||
|
||||
sleMpls OBJECT-IDENTITY
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"SLE MPLS."
|
||||
::= { sleMgmt 16 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfg OBJECT IDENTIFIER ::= { sleMplsTpTunnel 1 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF SleMplsTpTunnelCfgInfoEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The mplsTunnelTable allows new MPLS tunnels to be
|
||||
created between an LSR and a remote endpoint, and
|
||||
existing tunnels to be reconfigured or removed.
|
||||
Note that only point-to-point tunnel segments are
|
||||
supported, although multipoint-to-point and point-
|
||||
to-multipoint connections are supported by an LSR
|
||||
acting as a cross-connect. Each MPLS tunnel can
|
||||
thus have one out-segment originating at this LSR
|
||||
and/or one in-segment terminating at this LSR."
|
||||
::= { sleMplsTpTunnelCfg 1 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoEntry OBJECT-TYPE
|
||||
SYNTAX SleMplsTpTunnelCfgInfoEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in this table represents an MPLS tunnel.
|
||||
An entry can be created by a network administrator
|
||||
or by an SNMP agent as instructed by an MPLS
|
||||
signalling protocol. Whenever a new entry is
|
||||
created with mplsTunnelIsIf set to true(1), then a
|
||||
corresponding entry is created in ifTable as well
|
||||
(see RFC 2863). The ifType of this entry is
|
||||
mplsTunnel(150).
|
||||
|
||||
A tunnel entry needs to be uniquely identified across
|
||||
a MPLS network. Indices mplsTunnelIndex and
|
||||
mplsTunnelInstance uniquely identify a tunnel on
|
||||
the LSR originating the tunnel. To uniquely
|
||||
identify a tunnel across an MPLS network requires
|
||||
|
||||
index mplsTunnelIngressLSRId. The last index
|
||||
mplsTunnelEgressLSRId is useful in identifying all
|
||||
instances of a tunnel that terminate on the same
|
||||
egress LSR."
|
||||
REFERENCE
|
||||
"1. RFC 2863 - The Interfaces Group MIB, McCloghrie,
|
||||
K., and F. Kastenholtz, June 2000 "
|
||||
INDEX { sleMplsTpTunnelCfgInfoIndex }
|
||||
::= { sleMplsTpTunnelCfgInfoTable 1 }
|
||||
|
||||
|
||||
SleMplsTpTunnelCfgInfoEntry ::=
|
||||
SEQUENCE {
|
||||
sleMplsTpTunnelCfgInfoIndex
|
||||
Unsigned32,
|
||||
sleMplsTpTunnelCfgInfoName
|
||||
OCTET STRING,
|
||||
sleMplsTpTunnelCfgInfoId
|
||||
Unsigned32,
|
||||
sleMplsTpTunnelCfgInfoSrcIdType
|
||||
INTEGER,
|
||||
sleMplsTpTunnelCfgInfoSrcGId
|
||||
Unsigned32,
|
||||
sleMplsTpTunnelCfgInfoSrcCc
|
||||
MplsCcId,
|
||||
sleMplsTpTunnelCfgInfoSrcIcc
|
||||
MplsIccId,
|
||||
sleMplsTpTunnelCfgInfoSrcNodeId
|
||||
IpAddress,
|
||||
sleMplsTpTunnelCfgInfoDestIdType
|
||||
INTEGER,
|
||||
sleMplsTpTunnelCfgInfoDestGId
|
||||
Unsigned32,
|
||||
sleMplsTpTunnelCfgInfoDestCc
|
||||
MplsCcId,
|
||||
sleMplsTpTunnelCfgInfoDestIcc
|
||||
MplsIccId,
|
||||
sleMplsTpTunnelCfgInfoDestNodeId
|
||||
IpAddress,
|
||||
sleMplsTpTunnelCfgInfoMode
|
||||
INTEGER,
|
||||
sleMplsTpTunnelCfgInfoFwdInLabel
|
||||
MplsLabel,
|
||||
sleMplsTpTunnelCfgInfoFwdInIfIndex
|
||||
InterfaceIndexOrZero,
|
||||
sleMplsTpTunnelCfgInfoFwdOperation
|
||||
INTEGER,
|
||||
sleMplsTpTunnelCfgInfoFwdOutLabel
|
||||
MplsLabel,
|
||||
sleMplsTpTunnelCfgInfoFwdOutIfIndex
|
||||
InterfaceIndexOrZero,
|
||||
sleMplsTpTunnelCfgInfoFwdOutMac
|
||||
MacAddress,
|
||||
sleMplsTpTunnelCfgInfoRevInLabel
|
||||
MplsLabel,
|
||||
sleMplsTpTunnelCfgInfoRevInIfIndex
|
||||
InterfaceIndexOrZero,
|
||||
sleMplsTpTunnelCfgInfoRevOperation
|
||||
INTEGER,
|
||||
sleMplsTpTunnelCfgInfoRevOutLabel
|
||||
MplsLabel,
|
||||
sleMplsTpTunnelCfgInfoRevOutIfIndex
|
||||
InterfaceIndexOrZero,
|
||||
sleMplsTpTunnelCfgInfoRevOutMac
|
||||
MacAddress,
|
||||
sleMplsTpTunnelCfgInfoState
|
||||
INTEGER,
|
||||
sleMplsTpTunnelCfgInfoRole
|
||||
INTEGER,
|
||||
sleMplsTpTunnelCfgInfoAssociateTnlName
|
||||
OCTET STRING,
|
||||
sleMplsTpTunnelCfgInfoDescription
|
||||
OCTET STRING,
|
||||
sleMplsTpTunnelCfgInfoHlspRole
|
||||
INTEGER,
|
||||
sleMplsTpTunnelCfgInfoHlspServerTunnelName
|
||||
OCTET STRING,
|
||||
sleMplsTpTunnelCfgInfoQosPolicyName
|
||||
OCTET STRING
|
||||
}
|
||||
|
||||
sleMplsTpTunnelCfgInfoIndex OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (0..65535)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A unique value which identify an entry in this table."
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 1 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (0..16))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The canonical name assigned to the tunnel. This name
|
||||
can be used to refer to the tunnel on the LSR's
|
||||
console port. If mplsTunnelIsIf is set to true
|
||||
then the ifName of the interface corresponding to
|
||||
this tunnel should have a value equal to
|
||||
mplsTunnelName. Also see the description of ifName
|
||||
in RFC 2863."
|
||||
REFERENCE
|
||||
"RFC 2863 - The Interfaces Group MIB, McCloghrie, K.,
|
||||
and F. Kastenholtz, June 2000."
|
||||
DEFVAL { "" }
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 2 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoId OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (1..65535)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Uniquely identifies a set of tunnel instances
|
||||
between a pair of ingress and egress LSRs.
|
||||
Managers should obtain new values for row
|
||||
creation in this table by reading
|
||||
mplsTunnelIndexNext. When
|
||||
the MPLS signalling protocol is rsvp(2) this value
|
||||
SHOULD be equal to the value signaled in the
|
||||
Tunnel Id of the Session object. When the MPLS
|
||||
signalling protocol is crldp(3) this value
|
||||
SHOULD be equal to the value signaled in the
|
||||
LSP ID."
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 3 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoSrcIdType OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
ietf(1),
|
||||
itut(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the ietf or itut type."
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 4 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoSrcGId OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (1..4294967295)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This Object is used to display the GlobalID of IETF"
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 5 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoSrcCc OBJECT-TYPE
|
||||
SYNTAX MplsCcId
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This Object is used to display the Source CC-ID of ITUT"
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 6 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoSrcIcc OBJECT-TYPE
|
||||
SYNTAX MplsIccId
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This Object is used to set the Source ICC-ID of ITUT"
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 7 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoSrcNodeId OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This Object is used to display the Source Node ID of IETF and ITUT"
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 8 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoDestIdType OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
ietf(1),
|
||||
itut(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the ietf or itut type."
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 9 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoDestGId OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (1..4294967295)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This Object is used to set the Destination GlobalID of IETF"
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 10 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoDestCc OBJECT-TYPE
|
||||
SYNTAX MplsCcId
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This Object is used to display the Destination CC-ID of ITUT"
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 11 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoDestIcc OBJECT-TYPE
|
||||
SYNTAX MplsIccId
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This Object is used to set the Destination ICC-ID of ITUT"
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 12 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoDestNodeId OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This Object is used to display the Destination Node ID of IETF and ITUT"
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 13 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoMode OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
none(0),
|
||||
unidirectional(1),
|
||||
bidirectional(2),
|
||||
corouted(3),
|
||||
associate(4)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the Tunnel Mode"
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 14 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoFwdInLabel OBJECT-TYPE
|
||||
SYNTAX MplsLabel
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to display the Forward In Label.
|
||||
The lable range is 0 to 1048575. Here 0 to 15 are
|
||||
reserved labels. User allowed range is 16 to 1048575..
|
||||
|
||||
The default value 1048576 is invalid label "
|
||||
DEFVAL { 1048576 }
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 15 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoFwdInIfIndex OBJECT-TYPE
|
||||
SYNTAX InterfaceIndexOrZero
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the Forward IN Interface index "
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 16 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoFwdOperation OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
none(0),
|
||||
push(1),
|
||||
pop(2),
|
||||
swap(3)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the Forward Ilm OPeration ."
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 17 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoFwdOutLabel OBJECT-TYPE
|
||||
SYNTAX MplsLabel
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to display the Forward In Label.
|
||||
The lable range is 0 to 1048575. Here 0 to 15 are
|
||||
reserved labels. User allowed range is 16 to 1048575.
|
||||
|
||||
The default value 1048576 is invalid label "
|
||||
DEFVAL { 1048576 }
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 18 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoFwdOutIfIndex OBJECT-TYPE
|
||||
SYNTAX InterfaceIndexOrZero
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the Forward OUT Interface index "
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 19 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoFwdOutMac OBJECT-TYPE
|
||||
SYNTAX MacAddress
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to display the Forward OUT MAC ADDRESS "
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 20 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoRevInLabel OBJECT-TYPE
|
||||
SYNTAX MplsLabel
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to display the Forward In Label.
|
||||
The lable range is 0 to 1048575. Here 0 to 15 are
|
||||
reserved labels. User allowed range is 16 to 1048575.
|
||||
|
||||
The default value 1048576 is invalid label "
|
||||
DEFVAL { 1048576 }
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 21 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoRevInIfIndex OBJECT-TYPE
|
||||
SYNTAX InterfaceIndexOrZero
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the Reverse IN Interface index "
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 22 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoRevOperation OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
none(0),
|
||||
push(1),
|
||||
pop(2),
|
||||
swap(3)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the Reverse Ilm OPeration ."
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 23 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoRevOutLabel OBJECT-TYPE
|
||||
SYNTAX MplsLabel
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to display the Forward In Label.
|
||||
The lable range is 0 to 1048575. Here 0 to 15 are
|
||||
reserved labels. User allowed range is 16 to 1048575.
|
||||
|
||||
The default value 1048576 is invalid label "
|
||||
DEFVAL { 1048576 }
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 24 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoRevOutIfIndex OBJECT-TYPE
|
||||
SYNTAX InterfaceIndexOrZero
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the Reverse OUT Interface index "
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 25 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoRevOutMac OBJECT-TYPE
|
||||
SYNTAX MacAddress
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to display the Forward OUT MAC ADDRESS ."
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 26 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoState OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
up(1),
|
||||
down(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is to display status of the tunnel."
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 27 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoRole OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
source(0),
|
||||
transist(1),
|
||||
destination(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is to display Role of the tunnel."
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 28 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoAssociateTnlName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object to display associate of reverse tunnel."
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 29 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoDescription OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Description."
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 30 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoHlspRole OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
server(1),
|
||||
client(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the Hlsp Tunnel. whether the tunnel is Server or client.
|
||||
server (1) :- To set the Server Tunnel
|
||||
client(2) :- To set the Client Tunnel ."
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 31 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoHlspServerTunnelName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the server TunnelName,
|
||||
when sleMplsTpTunnelCfgControlHlspOption as a client ."
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 32 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgInfoQosPolicyName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the Qos Policy name."
|
||||
::= { sleMplsTpTunnelCfgInfoEntry 33 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControl OBJECT IDENTIFIER ::= { sleMplsTpTunnelCfg 2 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlRequest OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
createMplsTpTunnelEntry(1),
|
||||
deleteMplsTpTunnelEntry(2),
|
||||
setMplsTpTunnelMode(3),
|
||||
setNhlfe(4),
|
||||
setIlmPop(5),
|
||||
setIlmSwap(6),
|
||||
setAssociateTunnel(7),
|
||||
unsetNhlfe(8),
|
||||
unsetIlmPop(9),
|
||||
unsetIlmSwap(10),
|
||||
unsetAssociateTunnel(11),
|
||||
setDescription(12),
|
||||
setHlspServerLsp(13),
|
||||
setHlspClientLsp(14),
|
||||
unsetHlspServerLsp(15),
|
||||
unsetHlspClientLsp(16),
|
||||
setTunnelQosPolicyName(17),
|
||||
unsetTunnelQosPolicyName(18)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object holds the possible read-write columns that can be
|
||||
modified in the Tunnel table. For each read-write column of
|
||||
Tunnel table, a Set Operation controlvalue is added in this object."
|
||||
::= { sleMplsTpTunnelCfgControl 1 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlStatus OBJECT-TYPE
|
||||
SYNTAX SleControlStatusType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object displays the status of the configuration done."
|
||||
::= { sleMplsTpTunnelCfgControl 2 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlTimer OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is based on the SLE style where a timer is configured
|
||||
for every control table."
|
||||
::= { sleMplsTpTunnelCfgControl 3 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlTimeStamp OBJECT-TYPE
|
||||
SYNTAX TimeTicks
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object specifies the time at which the configuration is done."
|
||||
::= { sleMplsTpTunnelCfgControl 4 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlReqResult OBJECT-TYPE
|
||||
SYNTAX SleControlRequestResultType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The standard result of the SET operation is stored here."
|
||||
::= { sleMplsTpTunnelCfgControl 5 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (0..16))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The canonical name assigned to the tunnel. This name
|
||||
can be used to refer to the tunnel on the LSR's
|
||||
console port. If mplsTunnelIsIf is set to true
|
||||
then the ifName of the interface corresponding to
|
||||
this tunnel should have a value equal to
|
||||
SlemplsTunnelName. Also see the description of ifName
|
||||
in RFC 2863."
|
||||
REFERENCE
|
||||
"RFC 2863 - The Interfaces Group MIB, McCloghrie, K.,
|
||||
and F. Kastenholtz, June 2000."
|
||||
DEFVAL { "" }
|
||||
::= { sleMplsTpTunnelCfgControl 6 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlId OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (1..65535)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the tunnel Id ."
|
||||
::= { sleMplsTpTunnelCfgControl 7 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlSrcIdType OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
ietf(1),
|
||||
itut(2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the ietf or itut type."
|
||||
::= { sleMplsTpTunnelCfgControl 8 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlSrcGId OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (1..4294967295)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the source Global-Id for IETF ."
|
||||
::= { sleMplsTpTunnelCfgControl 9 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlSrcCc OBJECT-TYPE
|
||||
SYNTAX MplsCcId
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the source CC-ID for ITUT."
|
||||
::= { sleMplsTpTunnelCfgControl 10 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlSrcIcc OBJECT-TYPE
|
||||
SYNTAX MplsIccId
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the Source ICC-ID for ITUT."
|
||||
::= { sleMplsTpTunnelCfgControl 11 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlSrcNodeId OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the Source Node-Id for IETF and ITUT"
|
||||
::= { sleMplsTpTunnelCfgControl 12 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlDestIdType OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
ietf(1),
|
||||
itut(2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the ietf or itut type."
|
||||
::= { sleMplsTpTunnelCfgControl 13 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlDestGId OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (1)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the Destination Global-Id for IETF ."
|
||||
::= { sleMplsTpTunnelCfgControl 14 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlDestCc OBJECT-TYPE
|
||||
SYNTAX MplsCcId
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the Destination CC-ID for ITUT."
|
||||
::= { sleMplsTpTunnelCfgControl 15 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlDestIcc OBJECT-TYPE
|
||||
SYNTAX MplsIccId
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the Destination ICC-ID for ITUT."
|
||||
::= { sleMplsTpTunnelCfgControl 16 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlDestNodeId OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the Destination NodeID for IETF
|
||||
and ITUT."
|
||||
::= { sleMplsTpTunnelCfgControl 17 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlMode OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
unidirectional(1),
|
||||
bidirectional(2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the Tunnel mode ."
|
||||
::= { sleMplsTpTunnelCfgControl 18 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlPath OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
forwardPath(1),
|
||||
reversePath(2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to Set the forward path and reverse path
|
||||
tunnel."
|
||||
::= { sleMplsTpTunnelCfgControl 19 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlInLabel OBJECT-TYPE
|
||||
SYNTAX MplsLabel
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the Inlabel. "
|
||||
::= { sleMplsTpTunnelCfgControl 20 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlInInterface OBJECT-TYPE
|
||||
SYNTAX InterfaceIndexOrZero
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the Ininterface index."
|
||||
::= { sleMplsTpTunnelCfgControl 21 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlOperation OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
push(1),
|
||||
pop(2),
|
||||
swap(3)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the operation of Tuunel "
|
||||
::= { sleMplsTpTunnelCfgControl 22 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlOutLabel OBJECT-TYPE
|
||||
SYNTAX MplsLabel
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the outlabel. "
|
||||
::= { sleMplsTpTunnelCfgControl 23 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlOutInterface OBJECT-TYPE
|
||||
SYNTAX InterfaceIndexOrZero
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the outerinterface index."
|
||||
::= { sleMplsTpTunnelCfgControl 24 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlOutMacAddress OBJECT-TYPE
|
||||
SYNTAX MacAddress
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to Set the Out MacAddress ."
|
||||
::= { sleMplsTpTunnelCfgControl 25 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlAssociateTnlName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to Associated Forward tunnel and reverse tunnel
|
||||
with reverse tunnel name ."
|
||||
::= { sleMplsTpTunnelCfgControl 26 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlDescription OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Description."
|
||||
::= { sleMplsTpTunnelCfgControl 27 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlHlspSeverTunnelName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the server Tunnel name for associating server and client."
|
||||
::= { sleMplsTpTunnelCfgControl 28 }
|
||||
|
||||
|
||||
sleMplsTpTunnelCfgControlQosPolicyName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set the Qos Policy name."
|
||||
::= { sleMplsTpTunnelCfgControl 29 }
|
||||
|
||||
|
||||
|
||||
END
|
||||
|
||||
--
|
||||