@ -0,0 +1,393 @@
|
||||
--
|
||||
-- SLE-RED-MIB.my
|
||||
-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
|
||||
-- Monday, December 21, 2009 at 16:16:11
|
||||
--
|
||||
|
||||
SLE-RED-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
sleMgmt
|
||||
FROM DASAN-SMI
|
||||
SleControlStatusType, SleControlRequestResultType
|
||||
FROM SLE-TC-MIB
|
||||
OBJECT-GROUP, NOTIFICATION-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
TimeTicks, Gauge32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
|
||||
FROM SNMPv2-SMI;
|
||||
|
||||
|
||||
-- October 19, 2007 at 22:00 GMT
|
||||
-- 1.3.6.1.4.1.6296.101.22
|
||||
sleRed MODULE-IDENTITY
|
||||
LAST-UPDATED "200710192200Z" -- October 19, 2007 at 22:00 GMT
|
||||
ORGANIZATION
|
||||
"DASAN Networks."
|
||||
CONTACT-INFO
|
||||
"Contact-info."
|
||||
DESCRIPTION
|
||||
"This MIB contains information to support
|
||||
active/standby control redundancy."
|
||||
::= { sleMgmt 22 }
|
||||
|
||||
|
||||
|
||||
--
|
||||
-- Type definitions
|
||||
--
|
||||
|
||||
SleRedBoardIdType ::= INTEGER
|
||||
{
|
||||
sfuA(1),
|
||||
sfuB(2)
|
||||
}
|
||||
|
||||
SleRedModeType ::= INTEGER
|
||||
{
|
||||
redundant(1),
|
||||
standalone(2)
|
||||
}
|
||||
|
||||
SleRedFaultActionType ::= INTEGER
|
||||
{
|
||||
switchover(1),
|
||||
log(2),
|
||||
disable(3)
|
||||
}
|
||||
|
||||
SleRedReloadOSType ::= INTEGER
|
||||
{
|
||||
os1(1),
|
||||
os2(2),
|
||||
default(3)
|
||||
}
|
||||
|
||||
|
||||
|
||||
--
|
||||
-- Node definitions
|
||||
--
|
||||
|
||||
-- 1.3.6.1.4.1.6296.101.22.1
|
||||
sleRedBase OBJECT IDENTIFIER ::= { sleRed 1 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.6296.101.22.1.1
|
||||
sleRedInfo OBJECT IDENTIFIER ::= { sleRedBase 1 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.6296.101.22.1.1.1
|
||||
sleRedActiveBoard OBJECT-TYPE
|
||||
SYNTAX SleRedBoardIdType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indication of the actual service board identifier.
|
||||
Regardless of redundancy mode, it has actual service board id.
|
||||
"
|
||||
::= { sleRedInfo 1 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.6296.101.22.1.1.2
|
||||
sleRedMode OBJECT-TYPE
|
||||
SYNTAX SleRedModeType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"If two SFUs are installed in the system,
|
||||
it works as redundant mode. Otherwise, it works as standalone mode.
|
||||
"
|
||||
::= { sleRedInfo 2 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.6296.101.22.1.1.3
|
||||
sleRedFaultCrashAction OBJECT-TYPE
|
||||
SYNTAX SleRedFaultActionType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"If any software module is crashed, the given action is taken.
|
||||
For 'switchover' action, if the board is active and a standby board is available,
|
||||
'switchover' is carried out.
|
||||
|
||||
If a standby board is not available, just warning message is left.
|
||||
If it is a standby board, 'reset' is carried out.
|
||||
"
|
||||
::= { sleRedInfo 3 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.6296.101.22.1.1.4
|
||||
sleRedFaultTimeoutAction OBJECT-TYPE
|
||||
SYNTAX SleRedFaultActionType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"If any software module doesn't respond for healthcheck messages for the certain time,
|
||||
the given action is taken.
|
||||
For 'switchover' action, if the board is active and a standby board is available,
|
||||
'switchover' is carried out.
|
||||
|
||||
If a standby board is not available, just warning message is left.
|
||||
If it is a standby board, 'reset' is carried out.
|
||||
"
|
||||
::= { sleRedInfo 4 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.6296.101.22.1.1.5
|
||||
sleRedFaultTimeout OBJECT-TYPE
|
||||
SYNTAX INTEGER (5..720000)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Healthcheck timeout. If a software module doesn't respond for the given time,
|
||||
it is regarded as a timed-out module.
|
||||
|
||||
(Unit: second, default is '5')
|
||||
"
|
||||
::= { sleRedInfo 5 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.6296.101.22.1.1.6
|
||||
sleRedActivePrevState OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
activeInit(0),
|
||||
singleActiveReady(1),
|
||||
versionReport(2),
|
||||
softwareXfer(3),
|
||||
softwareXferDone(4),
|
||||
configXfer(5),
|
||||
configXferDone(6),
|
||||
stateXfer(7),
|
||||
activeReady(8),
|
||||
disconnectStandby(9),
|
||||
standbyWait(10),
|
||||
versionCheck(11),
|
||||
updateMac(12),
|
||||
softwareSync(13),
|
||||
softwareSyncDone(14),
|
||||
configSync(15),
|
||||
configSyncDone(16),
|
||||
startupSync(17),
|
||||
standbyReady(18),
|
||||
standbyReset(19)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Previous state of active board."
|
||||
::= { sleRedInfo 6 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.6296.101.22.1.1.7
|
||||
sleRedActiveCurrState OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
activeInit(0),
|
||||
singleActiveReady(1),
|
||||
versionReport(2),
|
||||
softwareXfer(3),
|
||||
softwareXferDone(4),
|
||||
configXfer(5),
|
||||
configXferDone(6),
|
||||
stateXfer(7),
|
||||
activeReady(8),
|
||||
disconnectStandby(9),
|
||||
standbyWait(10),
|
||||
versionCheck(11),
|
||||
updateMac(12),
|
||||
softwareSync(13),
|
||||
softwareSyncDone(14),
|
||||
configSync(15),
|
||||
configSyncDone(16),
|
||||
startupSync(17),
|
||||
standbyReady(18),
|
||||
standbyReset(19)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Current state of active board."
|
||||
::= { sleRedInfo 7 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.6296.101.22.1.2
|
||||
sleRedControl OBJECT IDENTIFIER ::= { sleRedBase 2 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.6296.101.22.1.2.1
|
||||
sleRedControlRequest OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
reloadStandby(1),
|
||||
switchover(2),
|
||||
setFaultMonitor(3)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"System commands related to control redundancy function.
|
||||
"
|
||||
::= { sleRedControl 1 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.6296.101.22.1.2.2
|
||||
sleRedControlStatus OBJECT-TYPE
|
||||
SYNTAX SleControlStatusType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The status of a user command.
|
||||
"
|
||||
::= { sleRedControl 2 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.6296.101.22.1.2.3
|
||||
sleRedControlTimer OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The maximum wait time for the manager for a long running user command.
|
||||
"
|
||||
::= { sleRedControl 3 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.6296.101.22.1.2.4
|
||||
sleRedControlTimeStamp OBJECT-TYPE
|
||||
SYNTAX TimeTicks
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The time stamp of the last command (end of command)."
|
||||
::= { sleRedControl 4 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.6296.101.22.1.2.5
|
||||
sleRedControlReqResult OBJECT-TYPE
|
||||
SYNTAX SleControlRequestResultType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The result of the last user command."
|
||||
::= { sleRedControl 5 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.6296.101.22.1.2.6
|
||||
sleRedControlReloadOS OBJECT-TYPE
|
||||
SYNTAX SleRedReloadOSType
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A mate board is reloaded with the given os.
|
||||
If 'default' is given, the board is reloaded with 'default' OS.
|
||||
"
|
||||
::= { sleRedControl 6 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.6296.101.22.1.2.7
|
||||
sleRedControlFaultCrashAction OBJECT-TYPE
|
||||
SYNTAX SleRedFaultActionType
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"If any software module is crashed, the given action is taken.
|
||||
For 'switchover' action, if the board is active and a standby board is available,
|
||||
'switchover' is carried out.
|
||||
|
||||
If a standby board is not available, just warning message is left.
|
||||
If it is a standby board, 'reset' is carried out.
|
||||
"
|
||||
::= { sleRedControl 7 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.6296.101.22.1.2.8
|
||||
sleRedControlFaultTimeoutAction OBJECT-TYPE
|
||||
SYNTAX SleRedFaultActionType
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"If any software module doesn't respond for healthcheck messages for the certain time,
|
||||
the given action is taken.
|
||||
For 'switchover' action, if the board is active and a standby board is available,
|
||||
'switchover' is carried out.
|
||||
|
||||
If a standby board is not available, just warning message is left.
|
||||
If it is a standby board, 'reset' is carried out.
|
||||
"
|
||||
::= { sleRedControl 8 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.6296.101.22.1.2.9
|
||||
sleRedControlFaultTimeout OBJECT-TYPE
|
||||
SYNTAX INTEGER (5..720000)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Healthcheck timeout. If a software module doesn't respond for the given time,
|
||||
it is regarded as a timed-out module.
|
||||
|
||||
(Unit: second, default is '5')
|
||||
"
|
||||
::= { sleRedControl 9 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.6296.101.22.1.3
|
||||
sleRedNotification OBJECT IDENTIFIER ::= { sleRedBase 3 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.6296.101.22.1.3.1
|
||||
sleRedMateReloadRequested NOTIFICATION-TYPE
|
||||
OBJECTS { sleRedControlRequest, sleRedControlTimeStamp, sleRedControlReqResult, sleRedActiveBoard }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A new active SFU indication"
|
||||
::= { sleRedNotification 1 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.6296.101.22.1.3.2
|
||||
sleRedSwitchoverRequested NOTIFICATION-TYPE
|
||||
OBJECTS { sleRedControlRequest, sleRedControlTimeStamp, sleRedControlReqResult }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The system redundancy mode has been changed. A standby board is pluged out or in."
|
||||
::= { sleRedNotification 2 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.6296.101.22.1.3.3
|
||||
sleRedFaultMonitorChanged NOTIFICATION-TYPE
|
||||
OBJECTS { sleRedControlRequest, sleRedControlTimeStamp, sleRedControlReqResult, sleRedControlFaultCrashAction, sleRedControlFaultTimeoutAction,
|
||||
sleRedControlFaultTimeout }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Fault monitor configuration has been changed."
|
||||
::= { sleRedNotification 3 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.6296.101.22.2
|
||||
sleRedGroup OBJECT-GROUP
|
||||
OBJECTS { sleRedActiveBoard, sleRedMode, sleRedFaultCrashAction, sleRedFaultTimeoutAction, sleRedFaultTimeout,
|
||||
sleRedControlStatus, sleRedControlTimer, sleRedControlTimeStamp, sleRedControlReqResult, sleRedControlReloadOS,
|
||||
sleRedControlFaultCrashAction, sleRedControlFaultTimeoutAction, sleRedActivePrevState, sleRedActiveCurrState, sleRedControlFaultTimeout,
|
||||
sleRedControlRequest }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Description."
|
||||
::= { sleRed 2 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.6296.101.22.3
|
||||
sleRedNotificationGroup NOTIFICATION-GROUP
|
||||
NOTIFICATIONS { sleRedMateReloadRequested, sleRedSwitchoverRequested, sleRedFaultMonitorChanged }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Description."
|
||||
::= { sleRed 3 }
|
||||
|
||||
|
||||
|
||||
END
|
||||
|
||||
--
|
||||