--  DLINKSW-DDM-MIB.mib : Digital Diagnostics Monitoring (DDM) MIB
 | 
			
		||||
--
 | 
			
		||||
--  Copyright (c) 2013 D-Link Corporation, all rights reserved.
 | 
			
		||||
--
 | 
			
		||||
--  *****************************************************************
 | 
			
		||||
DLINKSW-DDM-MIB DEFINITIONS ::= BEGIN
 | 
			
		||||
    IMPORTS
 | 
			
		||||
        DisplayString,TruthValue,RowStatus
 | 
			
		||||
            FROM SNMPv2-TC
 | 
			
		||||
        MODULE-IDENTITY,OBJECT-TYPE,Integer32
 | 
			
		||||
            FROM SNMPv2-SMI
 | 
			
		||||
        MODULE-COMPLIANCE,OBJECT-GROUP
 | 
			
		||||
		    FROM SNMPv2-CONF
 | 
			
		||||
        SnmpAdminString					
 | 
			
		||||
            FROM SNMP-FRAMEWORK-MIB
 | 
			
		||||
        ifIndex, InterfaceIndex
 | 
			
		||||
            FROM IF-MIB    
 | 
			
		||||
        dlinkIndustrialCommon		
 | 
			
		||||
            FROM DLINK-ID-REC-MIB;
 | 
			
		||||
   
 | 
			
		||||
    dlinkSwDdmMIB	MODULE-IDENTITY
 | 
			
		||||
   		LAST-UPDATED "201302040000Z"
 | 
			
		||||
   		ORGANIZATION "D-Link Corp."
 | 
			
		||||
        CONTACT-INFO
 | 
			
		||||
            "        D-Link Corporation
 | 
			
		||||
 | 
			
		||||
             Postal: No. 289, Sinhu 3rd Rd., Neihu District,
 | 
			
		||||
                     Taipei City 114, Taiwan, R.O.C
 | 
			
		||||
             Tel:     +886-2-66000123
 | 
			
		||||
             E-mail: tsd@dlink.com.tw
 | 
			
		||||
            "
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This MIB module defines objects for DDM."
 | 
			
		||||
            
 | 
			
		||||
        REVISION "201302040000Z"
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
		    "The structure of DDM for the proprietary enterprise."
 | 
			
		||||
		    
 | 
			
		||||
        REVISION "201309050000Z"
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "Modified the object dDdmAlarmTrap and dDdmWarningTrap to
 | 
			
		||||
            support to send traps when transceiver monitoring recovers from an
 | 
			
		||||
            abnormal warning/alarm situation to normal status."
 | 
			
		||||
        ::={ dlinkIndustrialCommon 72 } 
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
    DlinkThresholdState ::= TEXTUAL-CONVENTION
 | 
			
		||||
        STATUS  current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "Represents the state of a current monitoring value.
 | 
			
		||||
             Valid values are:
 | 
			
		||||
            
 | 
			
		||||
            normal(0): the current value is within normal range.
 | 
			
		||||
 | 
			
		||||
            higherAlarm(1):  the current value is higher than the high alarm threshold.
 | 
			
		||||
 | 
			
		||||
            higherWarning(2): the current value is higher than the high warning threshold.       
 | 
			
		||||
 | 
			
		||||
            lowerWarning(3):  the current value is lower than the low warning threshold.   
 | 
			
		||||
 | 
			
		||||
            lowerAlarm(4): the current value is lower than the low alarm threshold.       
 | 
			
		||||
            "
 | 
			
		||||
        SYNTAX  INTEGER {
 | 
			
		||||
            normal(0),
 | 
			
		||||
            higherAlarm(1),
 | 
			
		||||
            higherWarning(2),
 | 
			
		||||
            lowerWarning(3),
 | 
			
		||||
            lowerAlarm(4)                      
 | 
			
		||||
        }
 | 
			
		||||
                
 | 
			
		||||
	dDdmMIBNotifications 		OBJECT IDENTIFIER ::= { dlinkSwDdmMIB 0 }
 | 
			
		||||
	dDdmMIBObjects 			    OBJECT IDENTIFIER ::= { dlinkSwDdmMIB 1 }
 | 
			
		||||
	dDdmMIBConformance		    OBJECT IDENTIFIER ::= { dlinkSwDdmMIB 2 }
 | 
			
		||||
 | 
			
		||||
-- -------------------------------------------------------------------------- 
 | 
			
		||||
    dDdmCtrl			OBJECT IDENTIFIER ::= { dDdmMIBObjects 1 }
 | 
			
		||||
    
 | 
			
		||||
    dDdmNotifyEnable OBJECT-TYPE
 | 
			
		||||
        SYNTAX          BITS {
 | 
			
		||||
            alarm(0),
 | 
			
		||||
            warning(1)
 | 
			
		||||
        }
 | 
			
		||||
        MAX-ACCESS  read-write
 | 
			
		||||
        STATUS      current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates whether a specified notification is enabled or not.
 | 
			
		||||
            If a bit corresponding to a notification is set to 1, then 
 | 
			
		||||
            the specified notification can be generated.
 | 
			
		||||
 | 
			
		||||
            alarm(0)   - sending an alarm level notification. 
 | 
			
		||||
            warning(1) - sending an warning level notification.              
 | 
			
		||||
            "
 | 
			
		||||
        ::= { dDdmCtrl 1 }
 | 
			
		||||
        
 | 
			
		||||
 | 
			
		||||
-- -------------------------------------------------------------------------- 		
 | 
			
		||||
     dDdmIfCtrl			OBJECT IDENTIFIER ::= { dDdmMIBObjects 2 }
 | 
			
		||||
            
 | 
			
		||||
     dDdmIfCfgTable	OBJECT-TYPE
 | 
			
		||||
		SYNTAX          SEQUENCE OF DDdmIfCfgEntry
 | 
			
		||||
		MAX-ACCESS      not-accessible
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This table contains a list of interface-specific DDM configuration."
 | 
			
		||||
        ::= {dDdmIfCtrl 1}
 | 
			
		||||
      
 | 
			
		||||
    dDdmIfCfgEntry	OBJECT-TYPE
 | 
			
		||||
		SYNTAX	        DDdmIfCfgEntry
 | 
			
		||||
		MAX-ACCESS      not-accessible
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "An entry manages DDM state and action on an interface."
 | 
			
		||||
        INDEX  {  ifIndex }
 | 
			
		||||
      ::= {dDdmIfCfgTable 1}
 | 
			
		||||
      
 | 
			
		||||
    DDdmIfCfgEntry ::=
 | 
			
		||||
        SEQUENCE {
 | 
			
		||||
            dDdmIfCfgEnabled     TruthValue,
 | 
			
		||||
            dDdmShutdownLevel    INTEGER     
 | 
			
		||||
        }  
 | 
			
		||||
             
 | 
			
		||||
    dDdmIfCfgEnabled OBJECT-TYPE
 | 
			
		||||
		SYNTAX          TruthValue 	 	 
 | 
			
		||||
        MAX-ACCESS      read-write
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the status of optical transceiver-monitoring
 | 
			
		||||
            function for a SFP port.
 | 
			
		||||
            When a SFP with transceiver-monitoring capability is plugged in a
 | 
			
		||||
            port but the transceiver-monitoring function of the port is
 | 
			
		||||
            disabled, system will not detect the SFP's abnormal status but user
 | 
			
		||||
            still can check the current status via dDdmIfInfoTable."
 | 
			
		||||
        ::= {dDdmIfCfgEntry 1} 
 | 
			
		||||
    
 | 
			
		||||
    dDdmShutdownLevel OBJECT-TYPE
 | 
			
		||||
		SYNTAX  INTEGER {					
 | 
			
		||||
            none(1),
 | 
			
		||||
            alarm(2),
 | 
			
		||||
            warning(3)
 | 
			
		||||
        }
 | 
			
		||||
        MAX-ACCESS      read-write
 | 
			
		||||
        STATUS           current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
             "This object indicates the abnormal level which causes a port
 | 
			
		||||
             enter into errDisabled state.
 | 
			
		||||
             A value of 'none' indicates the shutdown action is disabled.
 | 
			
		||||
             "
 | 
			
		||||
        ::= {dDdmIfCfgEntry 2}    
 | 
			
		||||
              
 | 
			
		||||
-- --------------------------------------------------------------------------
 | 
			
		||||
    dDdmThresholdMgmt			OBJECT IDENTIFIER ::= { dDdmMIBObjects 3 }
 | 
			
		||||
    
 | 
			
		||||
    dDdmThresholdCfgTable	OBJECT-TYPE
 | 
			
		||||
		SYNTAX          SEQUENCE OF DDdmThresholdCfgEntry
 | 
			
		||||
		MAX-ACCESS      not-accessible
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This table contains a list of interface-specific threshold configuration for
 | 
			
		||||
            DDM."
 | 
			
		||||
        ::= {dDdmThresholdMgmt 1}
 | 
			
		||||
        
 | 
			
		||||
    dDdmThresholdCfgEntry OBJECT-TYPE
 | 
			
		||||
		SYNTAX          DDdmThresholdCfgEntry
 | 
			
		||||
        MAX-ACCESS      not-accessible
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "An entry in this table conists of one threshold configuration on an interface.
 | 
			
		||||
            An entry is created/removed when a configuration is added/deleted.
 | 
			
		||||
            "
 | 
			
		||||
        INDEX  { 
 | 
			
		||||
            ifIndex,
 | 
			
		||||
            dDdmThresholdComponent,
 | 
			
		||||
            dDmThresholdAbnormalLevel
 | 
			
		||||
        }
 | 
			
		||||
        ::= { dDdmThresholdCfgTable 1 }
 | 
			
		||||
 | 
			
		||||
    DDdmThresholdCfgEntry	::=
 | 
			
		||||
        SEQUENCE {
 | 
			
		||||
            dDdmThresholdComponent          INTEGER,
 | 
			
		||||
            dDmThresholdAbnormalLevel       INTEGER,
 | 
			
		||||
  		    dDdmThresholdCfgValue           Integer32,
 | 
			
		||||
  		    dDdmThresholdCfgRowStatus       RowStatus
 | 
			
		||||
  	    }
 | 
			
		||||
        		             
 | 
			
		||||
    dDdmThresholdComponent	OBJECT-TYPE
 | 
			
		||||
		SYNTAX	INTEGER {
 | 
			
		||||
            temperature(1),
 | 
			
		||||
            voltage(2),
 | 
			
		||||
            biasCurrent(3),
 | 
			
		||||
            txPowerMw(4),
 | 
			
		||||
            txPowerDbm(5),            
 | 
			
		||||
            rxPowerMw(6),
 | 
			
		||||
            rxPowerDbm(7)
 | 
			
		||||
        }  
 | 
			
		||||
        MAX-ACCESS      not-accessible
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the monitoring type.
 | 
			
		||||
            Note:
 | 
			
		||||
            Either txPowerMw(4) or txPowerDbm(5) can be configured on an interface.
 | 
			
		||||
            Either rxPowerMw(6) or rxPowerDbm(7) can be configured on an interface.
 | 
			
		||||
            In the above two cases, the existed entry will be deleted when the 
 | 
			
		||||
            other new entry is created.
 | 
			
		||||
            "
 | 
			
		||||
        ::= {dDdmThresholdCfgEntry 1}  
 | 
			
		||||
            
 | 
			
		||||
    dDmThresholdAbnormalLevel	OBJECT-TYPE
 | 
			
		||||
		SYNTAX	INTEGER {
 | 
			
		||||
            highAlarm(1),
 | 
			
		||||
            highWarning(2),
 | 
			
		||||
            lowWarning(3),
 | 
			
		||||
            lowAlarm(4)       
 | 
			
		||||
        }  
 | 
			
		||||
        MAX-ACCESS  not-accessible
 | 
			
		||||
        STATUS      current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the threshold type."
 | 
			
		||||
        ::= { dDdmThresholdCfgEntry 2 }      
 | 
			
		||||
        
 | 
			
		||||
   dDdmThresholdCfgValue	OBJECT-TYPE
 | 
			
		||||
		SYNTAX          Integer32
 | 
			
		||||
        MAX-ACCESS      read-create
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the configured threshold. The value is
 | 
			
		||||
            interpreted within the context of dDdmThresholdComponent and
 | 
			
		||||
            dDmThresholdAbnormalLevel in the same row. The unit and valid range
 | 
			
		||||
            are as follows:
 | 
			
		||||
            Threshold Type     Unit                           Valid Range
 | 
			
		||||
            =============      =====================          =================
 | 
			
		||||
            Temperature        milli-degrees Celsius          -128,000 ~ 127,996 
 | 
			
		||||
            voltage            centi-Volt                     0 ~ 655
 | 
			
		||||
            biasCurrent        milli-amperes                  0 ~ 131 
 | 
			
		||||
            txPowerMw          tenths of a microwatt            0 ~ 65,535
 | 
			
		||||
            txPowerDbm         ten-thousandths of DBM         -400,000 ~ 81,647
 | 
			
		||||
            rxPowerMw          tenths of a microwatt            0 ~ 65,535
 | 
			
		||||
            rxPowerDbm         ten-thousandths of DBM         -400,000 ~ 81,647            
 | 
			
		||||
            "
 | 
			
		||||
        ::= { dDdmThresholdCfgEntry 3 }  
 | 
			
		||||
        
 | 
			
		||||
    dDdmThresholdCfgRowStatus 	OBJECT-TYPE
 | 
			
		||||
		SYNTAX          RowStatus
 | 
			
		||||
        MAX-ACCESS      read-create
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "The status of this conceptual row."
 | 
			
		||||
        ::= { dDdmThresholdCfgEntry 4 }  
 | 
			
		||||
                         
 | 
			
		||||
-- -------------------------------------------------------------------------- 
 | 
			
		||||
    dDdmInfo  OBJECT IDENTIFIER ::= {  dDdmMIBObjects 4 }
 | 
			
		||||
 | 
			
		||||
    dDdmIfInfoTable	OBJECT-TYPE
 | 
			
		||||
		SYNTAX	        SEQUENCE OF DDdmIfInfoEntry
 | 
			
		||||
		MAX-ACCESS      not-accessible
 | 
			
		||||
		STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This table contains a list of information about current operating
 | 
			
		||||
            parameters of interfaces. Only the applicable interfaces (i.e.SFP
 | 
			
		||||
            module with DDM capability is plugged-in. ) will appear in this table.
 | 
			
		||||
            Note: 
 | 
			
		||||
            1. The threshold may be administratively configured or factory
 | 
			
		||||
               preset value defined by vendors. dDdmThresholdCfgTable provides
 | 
			
		||||
               the administrative threshold configuration.
 | 
			
		||||
            2. It doesn't necessarily means the DDM is enabled on the interface
 | 
			
		||||
               when an entry appears in this table. dDdmIfCfgTable provides such
 | 
			
		||||
               information."
 | 
			
		||||
        ::= {dDdmInfo 1}
 | 
			
		||||
        
 | 
			
		||||
    dDdmIfInfoEntry OBJECT-TYPE
 | 
			
		||||
		SYNTAX	        DDdmIfInfoEntry
 | 
			
		||||
		MAX-ACCESS      not-accessible
 | 
			
		||||
		STATUS	        current
 | 
			
		||||
		DESCRIPTION
 | 
			
		||||
			"An entry appears in this table contains current operating parameters
 | 
			
		||||
			for transceiver monitoring of a port."       
 | 
			
		||||
		INDEX  { ifIndex  }
 | 
			
		||||
		::= { dDdmIfInfoTable 1}
 | 
			
		||||
		
 | 
			
		||||
    DDdmIfInfoEntry ::=
 | 
			
		||||
		SEQUENCE {		    
 | 
			
		||||
		   dDdmIfInfoCurrentTemperature         Integer32,
 | 
			
		||||
		   dDdmIfInfoTemperatureState           DlinkThresholdState,
 | 
			
		||||
		   dDdmIfInfoHighAlarmTemperature       Integer32,
 | 
			
		||||
		   dDdmIfInfoHighWarnTemperature        Integer32,           
 | 
			
		||||
		   dDdmIfInfoLowWarnTemperature         Integer32,	
 | 
			
		||||
		   dDdmIfInfoLowAlarmTemperature        Integer32,	   
 | 
			
		||||
		   dDdmIfInfoCurrentVoltage             Integer32,
 | 
			
		||||
		   dDdmIfInfoVoltageState               DlinkThresholdState,
 | 
			
		||||
		   dDdmIfInfoHighAlarmVoltage           Integer32,
 | 
			
		||||
		   dDdmIfInfoHighWarnVoltage            Integer32,           
 | 
			
		||||
		   dDdmIfInfoLowWarnVoltage             Integer32,
 | 
			
		||||
		   dDdmIfInfoLowAlarmVoltage            Integer32,		   
 | 
			
		||||
		   dDdmIfInfoCurrentBiasCurrent         Integer32,
 | 
			
		||||
		   dDdmIfInfoBiasCurrentState           DlinkThresholdState,
 | 
			
		||||
		   dDdmIfInfoHighAlarmBiasCurrent       Integer32,
 | 
			
		||||
		   dDdmIfInfoHighWarnBiasCurrent        Integer32,
 | 
			
		||||
		   dDdmIfInfoLowWarnBiasCurrent         Integer32,   
 | 
			
		||||
           dDdmIfInfoLowAlarmBiasCurrent        Integer32,		  
 | 
			
		||||
		   dDdmIfInfoCurrentTxPower             Integer32,
 | 
			
		||||
		   dDdmIfInfoTxPowerState               DlinkThresholdState,
 | 
			
		||||
		   dDdmIfInfoHighAlarmTxPower           Integer32,
 | 
			
		||||
		   dDdmIfInfoHighWarnTxPower            Integer32,
 | 
			
		||||
		   dDdmIfInfoLowWarnTxPower             Integer32,
 | 
			
		||||
           dDdmIfInfoLowAlarmTxPower            Integer32,           
 | 
			
		||||
		   dDdmIfInfoCurrentRxPower             Integer32,
 | 
			
		||||
		   dDdmIfInfoRxPowerState               DlinkThresholdState,		   
 | 
			
		||||
		   dDdmIfInfoHighAlarmRxPower           Integer32,
 | 
			
		||||
		   dDdmIfInfoHighWarnRxPower            Integer32,           
 | 
			
		||||
		   dDdmIfInfoLowWarnRxPower             Integer32,
 | 
			
		||||
		   dDdmIfInfoLowAlarmRxPower            Integer32
 | 
			
		||||
        }
 | 
			
		||||
 
 | 
			
		||||
    dDdmIfInfoCurrentTemperature OBJECT-TYPE
 | 
			
		||||
        SYNTAX          Integer32
 | 
			
		||||
        UNITS           "milli-degrees Celsius"
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the current temperature in unit of 
 | 
			
		||||
            'milli-degrees Celsius' on the interface."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 1 }
 | 
			
		||||
        
 | 
			
		||||
    dDdmIfInfoTemperatureState OBJECT-TYPE
 | 
			
		||||
        SYNTAX          DlinkThresholdState   
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the state of current temperature."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 2 }
 | 
			
		||||
    
 | 
			
		||||
    dDdmIfInfoHighAlarmTemperature OBJECT-TYPE
 | 
			
		||||
        SYNTAX          Integer32
 | 
			
		||||
        UNITS           "milli-degrees Celsius"
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the high alarm threshold, when the operating
 | 
			
		||||
            temperature rises above this value, it indicates an alarm status.           
 | 
			
		||||
            The value is in unit of 'milli-degrees Celsius'."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 3 }     
 | 
			
		||||
      
 | 
			
		||||
      
 | 
			
		||||
    dDdmIfInfoHighWarnTemperature OBJECT-TYPE
 | 
			
		||||
        SYNTAX          Integer32
 | 
			
		||||
        UNITS           "milli-degrees Celsius"
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the high warning threshold, when the operating
 | 
			
		||||
            temperature rises above this value, it indicates a warning status.
 | 
			
		||||
            The value is in unit of 'milli-degrees Celsius'."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 4 }       
 | 
			
		||||
    
 | 
			
		||||
    dDdmIfInfoLowWarnTemperature OBJECT-TYPE       
 | 
			
		||||
        SYNTAX          Integer32
 | 
			
		||||
        UNITS           "milli-degrees Celsius"
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the low warning threshold, when the operating
 | 
			
		||||
            temperature falls below this value, it indicates a warning status.
 | 
			
		||||
            The value is in unit of 'milli-degrees Celsius'."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 5 }     
 | 
			
		||||
      
 | 
			
		||||
    dDdmIfInfoLowAlarmTemperature OBJECT-TYPE
 | 
			
		||||
        SYNTAX          Integer32
 | 
			
		||||
        UNITS           "milli-degrees Celsius"
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the low alarm threshold, when the operating
 | 
			
		||||
            temperature falls below this value, it indicates an alarm status.
 | 
			
		||||
            The value is in unit of 'milli-degrees Celsius'."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 6 }            
 | 
			
		||||
   
 | 
			
		||||
    dDdmIfInfoCurrentVoltage OBJECT-TYPE
 | 
			
		||||
        SYNTAX          Integer32
 | 
			
		||||
        UNITS           "centi-Volt"
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the current voltage in unit of 
 | 
			
		||||
            'centi-Volt' on the interface."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 7 }
 | 
			
		||||
        
 | 
			
		||||
    dDdmIfInfoVoltageState OBJECT-TYPE
 | 
			
		||||
        SYNTAX          DlinkThresholdState             
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the state of current voltage."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 8 }
 | 
			
		||||
    
 | 
			
		||||
    dDdmIfInfoHighAlarmVoltage OBJECT-TYPE
 | 
			
		||||
        SYNTAX          Integer32
 | 
			
		||||
        UNITS           "centi-Volt"
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the high alarm threshold, when the operating
 | 
			
		||||
            voltage rises above this value, it indicates an alarm status.
 | 
			
		||||
            The value is in unit of 'centi-Volt'."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 9 }     
 | 
			
		||||
      
 | 
			
		||||
    dDdmIfInfoHighWarnVoltage OBJECT-TYPE
 | 
			
		||||
        SYNTAX          Integer32
 | 
			
		||||
        UNITS           "centi-Volt"
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the high warning threshold, when the operating
 | 
			
		||||
            voltage rises above this value, it indicates a warning status.
 | 
			
		||||
            The value is in unit of 'centi-Volt'."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 10 }       
 | 
			
		||||
    
 | 
			
		||||
    dDdmIfInfoLowWarnVoltage OBJECT-TYPE       
 | 
			
		||||
        SYNTAX          Integer32
 | 
			
		||||
        UNITS           "centi-Volt"
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the low warning threshold, when the operating
 | 
			
		||||
            voltage falls below this value, it indicates a warning status.
 | 
			
		||||
            The value is in unit of 'centi-Volt'."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 11 }     
 | 
			
		||||
      
 | 
			
		||||
    dDdmIfInfoLowAlarmVoltage OBJECT-TYPE
 | 
			
		||||
        SYNTAX          Integer32
 | 
			
		||||
        UNITS           "centi-Volt"
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the low alarm threshold, when the operating
 | 
			
		||||
            voltage falls below this value, it indicates an alarm status.
 | 
			
		||||
            The value is in unit of 'centi-Volt'."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 12 }             
 | 
			
		||||
   
 | 
			
		||||
   dDdmIfInfoCurrentBiasCurrent OBJECT-TYPE
 | 
			
		||||
        SYNTAX          Integer32
 | 
			
		||||
        UNITS           "milli-amperes"
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the current bias current in unit of 
 | 
			
		||||
            'milli-amperes' on the interface."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 13 }
 | 
			
		||||
        
 | 
			
		||||
    dDdmIfInfoBiasCurrentState OBJECT-TYPE
 | 
			
		||||
        SYNTAX          DlinkThresholdState
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the state of current BiasCurrent."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 14 }
 | 
			
		||||
    
 | 
			
		||||
    dDdmIfInfoHighAlarmBiasCurrent OBJECT-TYPE
 | 
			
		||||
        SYNTAX          Integer32
 | 
			
		||||
        UNITS           "milli-amperes"
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the high alarm threshold, when the operating
 | 
			
		||||
            bias current rises above this value, it indicates an alarm status.
 | 
			
		||||
            The value is in unit of 'milli-amperes'."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 15 }     
 | 
			
		||||
      
 | 
			
		||||
    dDdmIfInfoHighWarnBiasCurrent OBJECT-TYPE
 | 
			
		||||
        SYNTAX          Integer32
 | 
			
		||||
        UNITS           "milli-amperes"
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the high warning threshold, when the operating
 | 
			
		||||
            bias current rises above this value, it indicates a warning status.
 | 
			
		||||
            The value is in unit of 'milli-amperes'."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 16 }       
 | 
			
		||||
    
 | 
			
		||||
    dDdmIfInfoLowWarnBiasCurrent OBJECT-TYPE       
 | 
			
		||||
        SYNTAX          Integer32
 | 
			
		||||
        UNITS           "milli-amperes"
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the low warning threshold, when the operating
 | 
			
		||||
            bias current falls below this value, it indicates a warning status.
 | 
			
		||||
            The value is in unit of 'milli-amperes'."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 17 }     
 | 
			
		||||
      
 | 
			
		||||
    dDdmIfInfoLowAlarmBiasCurrent OBJECT-TYPE
 | 
			
		||||
        SYNTAX          Integer32
 | 
			
		||||
        UNITS           "milli-amperes"
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the low alarm threshold, when the operating
 | 
			
		||||
            bias current falls below this value, it indicates an alarm status.
 | 
			
		||||
            The value is in unit of 'milli-amperes'."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 18 }            
 | 
			
		||||
 | 
			
		||||
    dDdmIfInfoCurrentTxPower OBJECT-TYPE
 | 
			
		||||
        SYNTAX          Integer32
 | 
			
		||||
        UNITS           "tenths of a microwatt"
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the current output power in unit of 
 | 
			
		||||
            'tenths of a microwatt' on the interface."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 19 }
 | 
			
		||||
        
 | 
			
		||||
    dDdmIfInfoTxPowerState OBJECT-TYPE
 | 
			
		||||
        SYNTAX          DlinkThresholdState
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the state of current output power."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 20 }
 | 
			
		||||
    
 | 
			
		||||
    dDdmIfInfoHighAlarmTxPower OBJECT-TYPE
 | 
			
		||||
        SYNTAX          Integer32
 | 
			
		||||
        UNITS           "tenths of a microwatt"
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the high alarm threshold, when the operating
 | 
			
		||||
            output power rises above this value, it indicates an alarm status.
 | 
			
		||||
            The value is in unit of 'tenths of a microwatt'."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 21 }     
 | 
			
		||||
      
 | 
			
		||||
    dDdmIfInfoHighWarnTxPower OBJECT-TYPE
 | 
			
		||||
        SYNTAX          Integer32
 | 
			
		||||
        UNITS           "tenths of a microwatt"
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the high warning threshold, when the operating
 | 
			
		||||
            output power rises above this value, it indicates a warning status.
 | 
			
		||||
            The value is in unit of 'tenths of a microwatt'."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 22 }       
 | 
			
		||||
    
 | 
			
		||||
    dDdmIfInfoLowWarnTxPower OBJECT-TYPE       
 | 
			
		||||
        SYNTAX          Integer32
 | 
			
		||||
        UNITS           "tenths of a microwatt"
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the low warning threshold, when the operating
 | 
			
		||||
            output power falls below this value, it indicates a warning status.
 | 
			
		||||
            The value is in unit of 'tenths of a microwatt'."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 23 }     
 | 
			
		||||
      
 | 
			
		||||
    dDdmIfInfoLowAlarmTxPower OBJECT-TYPE
 | 
			
		||||
        SYNTAX          Integer32
 | 
			
		||||
        UNITS           "tenths of a microwatt"
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the low alarm threshold, when the operating
 | 
			
		||||
            output power falls below this value, it indicates an alarm status.
 | 
			
		||||
            The value is in unit of 'tenths of a microwatt'."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 24 }  
 | 
			
		||||
        
 | 
			
		||||
    dDdmIfInfoCurrentRxPower OBJECT-TYPE
 | 
			
		||||
        SYNTAX          Integer32
 | 
			
		||||
        UNITS           "tenths of a microwatt"
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the current input power in unit of 
 | 
			
		||||
            'tenths of a microwatt' on the interface."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 25 }
 | 
			
		||||
        
 | 
			
		||||
    dDdmIfInfoRxPowerState OBJECT-TYPE
 | 
			
		||||
        SYNTAX          DlinkThresholdState
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the state of current input power."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 26 }
 | 
			
		||||
    
 | 
			
		||||
    dDdmIfInfoHighAlarmRxPower OBJECT-TYPE
 | 
			
		||||
        SYNTAX          Integer32
 | 
			
		||||
        UNITS           "tenths of a microwatt"
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the high alarm threshold, when the operating
 | 
			
		||||
            input power rises above this value, it indicates an alarm status.
 | 
			
		||||
            The value is in unit of 'tenths of a microwatt'."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 27 }     
 | 
			
		||||
      
 | 
			
		||||
    dDdmIfInfoHighWarnRxPower OBJECT-TYPE
 | 
			
		||||
        SYNTAX          Integer32
 | 
			
		||||
        UNITS           "tenths of a microwatt"
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the high warning threshold, when the operating
 | 
			
		||||
            input power rises above this value, it indicates a warning status.
 | 
			
		||||
            The value is in unit of 'tenths of a microwatt'."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 28 }       
 | 
			
		||||
    
 | 
			
		||||
    dDdmIfInfoLowWarnRxPower OBJECT-TYPE       
 | 
			
		||||
        SYNTAX          Integer32
 | 
			
		||||
        UNITS           "tenths of a microwatt"
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the low warning threshold, when the operating
 | 
			
		||||
            input power falls below this value, it indicates a warning status.
 | 
			
		||||
            The value is in unit of 'tenths of a microwatt'."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 29 }     
 | 
			
		||||
      
 | 
			
		||||
    dDdmIfInfoLowAlarmRxPower OBJECT-TYPE
 | 
			
		||||
        SYNTAX          Integer32
 | 
			
		||||
        UNITS           "tenths of a microwatt"
 | 
			
		||||
        MAX-ACCESS      read-only
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object indicates the low alarm threshold, when the operating
 | 
			
		||||
            input power falls below this value, it indicates an alarm status.
 | 
			
		||||
            The value is in unit of 'tenths of a microwatt'."
 | 
			
		||||
        ::= { dDdmIfInfoEntry 30 }  
 | 
			
		||||
        
 | 
			
		||||
-- --------------------------------------------------------------------------
 | 
			
		||||
   dDdmNotifyInfo  OBJECT IDENTIFIER ::= {  dDdmMIBObjects 5 }
 | 
			
		||||
 | 
			
		||||
   dDdmNotifyInfoIfIndex OBJECT-TYPE
 | 
			
		||||
		SYNTAX 	        InterfaceIndex
 | 
			
		||||
		MAX-ACCESS      accessible-for-notify
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
              "This object is used by dDdmAlarmTrap and dDdmWarningTrap to indicate 
 | 
			
		||||
              the ifIndex on which the monitoring value rises above or falls below
 | 
			
		||||
              the corresponding threshold."
 | 
			
		||||
              ::= { dDdmNotifyInfo 1 }
 | 
			
		||||
  
 | 
			
		||||
    dDdmNotifyInfoComponent OBJECT-TYPE
 | 
			
		||||
		SYNTAX 	INTEGER{
 | 
			
		||||
			temperature(1),
 | 
			
		||||
            voltage(2),
 | 
			
		||||
            biasCurrent(3),
 | 
			
		||||
            txPowerMw(4),                        
 | 
			
		||||
            rxPowerMw(5)           
 | 
			
		||||
	    }
 | 
			
		||||
		MAX-ACCESS      accessible-for-notify
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
              "This object is used by dDdmAlarmTrap and dDdmWarningTrap to indicate  
 | 
			
		||||
              the abnormal component."
 | 
			
		||||
        ::= { dDdmNotifyInfo 2 }
 | 
			
		||||
         
 | 
			
		||||
    dDdmNotifyInfoAbnormalLevel OBJECT-TYPE
 | 
			
		||||
		SYNTAX 	INTEGER{
 | 
			
		||||
			high(1),
 | 
			
		||||
			low(2)
 | 
			
		||||
		}
 | 
			
		||||
		MAX-ACCESS  accessible-for-notify
 | 
			
		||||
        STATUS  current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "This object is used by dDdmAlarmTrap and dDdmWarningTrap to indicate  
 | 
			
		||||
            the abnormal level."
 | 
			
		||||
        ::= { dDdmNotifyInfo 3 }
 | 
			
		||||
        
 | 
			
		||||
    dDdmNotifyInfoThresholdExceedOrRecover OBJECT-TYPE
 | 
			
		||||
		SYNTAX 	INTEGER{
 | 
			
		||||
					exceed(1),
 | 
			
		||||
					recover(2)
 | 
			
		||||
			}
 | 
			
		||||
		MAX-ACCESS  accessible-for-notify
 | 
			
		||||
    STATUS  current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "This object is used by dDdmAlarmTrap and dDdmWarningTrap to indicate the
 | 
			
		||||
        GBIC is exceeding its threshold or recover to
 | 
			
		||||
        normal status."
 | 
			
		||||
        ::= {dDdmNotifyInfo 4}
 | 
			
		||||
             
 | 
			
		||||
 
 | 
			
		||||
-- --------------------------------------------------------------------------
 | 
			
		||||
 | 
			
		||||
    dDdmAlarmTrap NOTIFICATION-TYPE
 | 
			
		||||
        OBJECTS  {
 | 
			
		||||
            dDdmNotifyInfoIfIndex,
 | 
			
		||||
            dDdmNotifyInfoComponent,
 | 
			
		||||
            dDdmNotifyInfoAbnormalLevel,
 | 
			
		||||
            dDdmNotifyInfoThresholdExceedOrRecover    					
 | 
			
		||||
        }        
 | 
			
		||||
        STATUS          current
 | 
			
		||||
        DESCRIPTION
 | 
			
		||||
            "The trap is sent when dDdmNotifyEnable is 'true' and an abnormal 
 | 
			
		||||
            alarm situation occurs or recovers from an abnormal alarm situation
 | 
			
		||||
            to normal status."
 | 
			
		||||
      ::= { dDdmMIBNotifications 1 }
 | 
			
		||||
      
 | 
			
		||||
    dDdmWarningTrap NOTIFICATION-TYPE
 | 
			
		||||
        OBJECTS         {
 | 
			
		||||
    	    dDdmNotifyInfoIfIndex,
 | 
			
		||||
    	    dDdmNotifyInfoComponent, 
 | 
			
		||||
    	    dDdmNotifyInfoAbnormalLevel,
 | 
			
		||||
            dDdmNotifyInfoThresholdExceedOrRecover   						  					
 | 
			
		||||
       }        
 | 
			
		||||
       STATUS              current
 | 
			
		||||
       DESCRIPTION
 | 
			
		||||
            "The trap is sent when dDdmNotifyEnable is 'true' and an abnormal 
 | 
			
		||||
            warning situation occurs or recovers from an abnormal warning
 | 
			
		||||
            situation to normal status."
 | 
			
		||||
      ::= { dDdmMIBNotifications 2 }
 | 
			
		||||
 | 
			
		||||
--  ***************************************************************************	
 | 
			
		||||
--  Conformance
 | 
			
		||||
--  ***************************************************************************			   		
 | 
			
		||||
	dDdmCompliances OBJECT IDENTIFIER ::= { dDdmMIBConformance 1 }
 | 
			
		||||
		
 | 
			
		||||
	dDdmCompliance MODULE-COMPLIANCE
 | 
			
		||||
		STATUS current
 | 
			
		||||
		DESCRIPTION 
 | 
			
		||||
			"The compliance statement for entities which implement the 
 | 
			
		||||
			DLINKSW-DDM-MIB."
 | 
			
		||||
		MODULE -- this module
 | 
			
		||||
		MANDATORY-GROUPS { 
 | 
			
		||||
		    dDdmInfoGroup,
 | 
			
		||||
		    dDdmCfgGroup,
 | 
			
		||||
		    dDdmNotifyGroup        		   
 | 
			
		||||
		}						
 | 
			
		||||
		::= { dDdmCompliances 1 }
 | 
			
		||||
		
 | 
			
		||||
	dDdmGroups OBJECT IDENTIFIER ::= { dDdmMIBConformance 2 }
 | 
			
		||||
	
 | 
			
		||||
	dDdmInfoGroup OBJECT-GROUP
 | 
			
		||||
		OBJECTS { 
 | 
			
		||||
             dDdmIfInfoCurrentTemperature, dDdmIfInfoTemperatureState,
 | 
			
		||||
             dDdmIfInfoHighAlarmTemperature, dDdmIfInfoHighWarnTemperature,              
 | 
			
		||||
             dDdmIfInfoLowWarnTemperature, dDdmIfInfoLowAlarmTemperature,              
 | 
			
		||||
             dDdmIfInfoCurrentVoltage, dDdmIfInfoVoltageState,        
 | 
			
		||||
             dDdmIfInfoHighAlarmVoltage, dDdmIfInfoHighWarnVoltage,                  
 | 
			
		||||
             dDdmIfInfoLowWarnVoltage, dDdmIfInfoLowAlarmVoltage,     
 | 
			
		||||
             dDdmIfInfoCurrentBiasCurrent, dDdmIfInfoBiasCurrentState,    
 | 
			
		||||
             dDdmIfInfoHighAlarmBiasCurrent, dDdmIfInfoHighWarnBiasCurrent, 
 | 
			
		||||
             dDdmIfInfoLowWarnBiasCurrent, dDdmIfInfoLowAlarmBiasCurrent, 
 | 
			
		||||
             dDdmIfInfoCurrentTxPower, dDdmIfInfoTxPowerState,
 | 
			
		||||
             dDdmIfInfoHighAlarmTxPower, dDdmIfInfoHighWarnTxPower,
 | 
			
		||||
             dDdmIfInfoLowWarnTxPower, dDdmIfInfoLowAlarmTxPower,
 | 
			
		||||
             dDdmIfInfoCurrentRxPower, dDdmIfInfoRxPowerState,
 | 
			
		||||
             dDdmIfInfoHighAlarmRxPower, dDdmIfInfoHighWarnRxPower,
 | 
			
		||||
             dDdmIfInfoLowWarnRxPower, dDdmIfInfoLowAlarmRxPower,
 | 
			
		||||
             dDdmNotifyInfoIfIndex, dDdmNotifyInfoComponent,
 | 
			
		||||
             dDdmNotifyInfoAbnormalLevel,
 | 
			
		||||
             dDdmNotifyInfoThresholdExceedOrRecover    						
 | 
			
		||||
		}
 | 
			
		||||
		STATUS current
 | 
			
		||||
		DESCRIPTION 
 | 
			
		||||
			"A collection of objects provides DDM operating information."
 | 
			
		||||
		::= { dDdmGroups 1 }
 | 
			
		||||
        
 | 
			
		||||
    dDdmCfgGroup OBJECT-GROUP
 | 
			
		||||
		OBJECTS { 
 | 
			
		||||
			dDdmNotifyEnable,
 | 
			
		||||
			dDdmIfCfgEnabled, dDdmShutdownLevel,
 | 
			
		||||
			dDdmThresholdCfgValue,	dDdmThresholdCfgRowStatus 
 | 
			
		||||
			
 | 
			
		||||
		}
 | 
			
		||||
		STATUS current
 | 
			
		||||
		DESCRIPTION 
 | 
			
		||||
			"A collection of objects provides DDM configuration."
 | 
			
		||||
		::= { dDdmGroups 2 }    
 | 
			
		||||
	
 | 
			
		||||
	dDdmNotifyGroup NOTIFICATION-GROUP
 | 
			
		||||
		NOTIFICATIONS { 
 | 
			
		||||
			dDdmAlarmTrap,
 | 
			
		||||
			dDdmWarningTrap
 | 
			
		||||
		}
 | 
			
		||||
		STATUS current
 | 
			
		||||
		DESCRIPTION 
 | 
			
		||||
			"The collection of notifications used for DDM."
 | 
			
		||||
		::= { dDdmGroups 3 }      
 | 
			
		||||
      
 | 
			
		||||
END
 | 
			
		||||