@ -0,0 +1,777 @@
|
||||
-- *****************************************************************
|
||||
-- DLINKSW-DDM-MIB.mib : Digital Diagnostics Monitoring (DDM) MIB
|
||||
--
|
||||
-- Copyright (c) 2013 D-Link Corporation, all rights reserved.
|
||||
--
|
||||
-- *****************************************************************
|
||||
DLINKSW-DDM-MIB DEFINITIONS ::= BEGIN
|
||||
IMPORTS
|
||||
DisplayString,TruthValue,RowStatus
|
||||
FROM SNMPv2-TC
|
||||
MODULE-IDENTITY,OBJECT-TYPE,Integer32
|
||||
FROM SNMPv2-SMI
|
||||
MODULE-COMPLIANCE,OBJECT-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
SnmpAdminString
|
||||
FROM SNMP-FRAMEWORK-MIB
|
||||
ifIndex, InterfaceIndex
|
||||
FROM IF-MIB
|
||||
dlinkIndustrialCommon
|
||||
FROM DLINK-ID-REC-MIB;
|
||||
|
||||
dlinkSwDdmMIB MODULE-IDENTITY
|
||||
LAST-UPDATED "201302040000Z"
|
||||
ORGANIZATION "D-Link Corp."
|
||||
CONTACT-INFO
|
||||
" D-Link Corporation
|
||||
|
||||
Postal: No. 289, Sinhu 3rd Rd., Neihu District,
|
||||
Taipei City 114, Taiwan, R.O.C
|
||||
Tel: +886-2-66000123
|
||||
E-mail: tsd@dlink.com.tw
|
||||
"
|
||||
DESCRIPTION
|
||||
"This MIB module defines objects for DDM."
|
||||
|
||||
REVISION "201302040000Z"
|
||||
DESCRIPTION
|
||||
"The structure of DDM for the proprietary enterprise."
|
||||
|
||||
REVISION "201309050000Z"
|
||||
DESCRIPTION
|
||||
"Modified the object dDdmAlarmTrap and dDdmWarningTrap to
|
||||
support to send traps when transceiver monitoring recovers from an
|
||||
abnormal warning/alarm situation to normal status."
|
||||
::={ dlinkIndustrialCommon 72 }
|
||||
|
||||
|
||||
DlinkThresholdState ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Represents the state of a current monitoring value.
|
||||
Valid values are:
|
||||
|
||||
normal(0): the current value is within normal range.
|
||||
|
||||
higherAlarm(1): the current value is higher than the high alarm threshold.
|
||||
|
||||
higherWarning(2): the current value is higher than the high warning threshold.
|
||||
|
||||
lowerWarning(3): the current value is lower than the low warning threshold.
|
||||
|
||||
lowerAlarm(4): the current value is lower than the low alarm threshold.
|
||||
"
|
||||
SYNTAX INTEGER {
|
||||
normal(0),
|
||||
higherAlarm(1),
|
||||
higherWarning(2),
|
||||
lowerWarning(3),
|
||||
lowerAlarm(4)
|
||||
}
|
||||
|
||||
dDdmMIBNotifications OBJECT IDENTIFIER ::= { dlinkSwDdmMIB 0 }
|
||||
dDdmMIBObjects OBJECT IDENTIFIER ::= { dlinkSwDdmMIB 1 }
|
||||
dDdmMIBConformance OBJECT IDENTIFIER ::= { dlinkSwDdmMIB 2 }
|
||||
|
||||
-- --------------------------------------------------------------------------
|
||||
dDdmCtrl OBJECT IDENTIFIER ::= { dDdmMIBObjects 1 }
|
||||
|
||||
dDdmNotifyEnable OBJECT-TYPE
|
||||
SYNTAX BITS {
|
||||
alarm(0),
|
||||
warning(1)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates whether a specified notification is enabled or not.
|
||||
If a bit corresponding to a notification is set to 1, then
|
||||
the specified notification can be generated.
|
||||
|
||||
alarm(0) - sending an alarm level notification.
|
||||
warning(1) - sending an warning level notification.
|
||||
"
|
||||
::= { dDdmCtrl 1 }
|
||||
|
||||
|
||||
-- --------------------------------------------------------------------------
|
||||
dDdmIfCtrl OBJECT IDENTIFIER ::= { dDdmMIBObjects 2 }
|
||||
|
||||
dDdmIfCfgTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF DDdmIfCfgEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains a list of interface-specific DDM configuration."
|
||||
::= {dDdmIfCtrl 1}
|
||||
|
||||
dDdmIfCfgEntry OBJECT-TYPE
|
||||
SYNTAX DDdmIfCfgEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry manages DDM state and action on an interface."
|
||||
INDEX { ifIndex }
|
||||
::= {dDdmIfCfgTable 1}
|
||||
|
||||
DDdmIfCfgEntry ::=
|
||||
SEQUENCE {
|
||||
dDdmIfCfgEnabled TruthValue,
|
||||
dDdmShutdownLevel INTEGER
|
||||
}
|
||||
|
||||
dDdmIfCfgEnabled OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the status of optical transceiver-monitoring
|
||||
function for a SFP port.
|
||||
When a SFP with transceiver-monitoring capability is plugged in a
|
||||
port but the transceiver-monitoring function of the port is
|
||||
disabled, system will not detect the SFP's abnormal status but user
|
||||
still can check the current status via dDdmIfInfoTable."
|
||||
::= {dDdmIfCfgEntry 1}
|
||||
|
||||
dDdmShutdownLevel OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
none(1),
|
||||
alarm(2),
|
||||
warning(3)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the abnormal level which causes a port
|
||||
enter into errDisabled state.
|
||||
A value of 'none' indicates the shutdown action is disabled.
|
||||
"
|
||||
::= {dDdmIfCfgEntry 2}
|
||||
|
||||
-- --------------------------------------------------------------------------
|
||||
dDdmThresholdMgmt OBJECT IDENTIFIER ::= { dDdmMIBObjects 3 }
|
||||
|
||||
dDdmThresholdCfgTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF DDdmThresholdCfgEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains a list of interface-specific threshold configuration for
|
||||
DDM."
|
||||
::= {dDdmThresholdMgmt 1}
|
||||
|
||||
dDdmThresholdCfgEntry OBJECT-TYPE
|
||||
SYNTAX DDdmThresholdCfgEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in this table conists of one threshold configuration on an interface.
|
||||
An entry is created/removed when a configuration is added/deleted.
|
||||
"
|
||||
INDEX {
|
||||
ifIndex,
|
||||
dDdmThresholdComponent,
|
||||
dDmThresholdAbnormalLevel
|
||||
}
|
||||
::= { dDdmThresholdCfgTable 1 }
|
||||
|
||||
DDdmThresholdCfgEntry ::=
|
||||
SEQUENCE {
|
||||
dDdmThresholdComponent INTEGER,
|
||||
dDmThresholdAbnormalLevel INTEGER,
|
||||
dDdmThresholdCfgValue Integer32,
|
||||
dDdmThresholdCfgRowStatus RowStatus
|
||||
}
|
||||
|
||||
dDdmThresholdComponent OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
temperature(1),
|
||||
voltage(2),
|
||||
biasCurrent(3),
|
||||
txPowerMw(4),
|
||||
txPowerDbm(5),
|
||||
rxPowerMw(6),
|
||||
rxPowerDbm(7)
|
||||
}
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the monitoring type.
|
||||
Note:
|
||||
Either txPowerMw(4) or txPowerDbm(5) can be configured on an interface.
|
||||
Either rxPowerMw(6) or rxPowerDbm(7) can be configured on an interface.
|
||||
In the above two cases, the existed entry will be deleted when the
|
||||
other new entry is created.
|
||||
"
|
||||
::= {dDdmThresholdCfgEntry 1}
|
||||
|
||||
dDmThresholdAbnormalLevel OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
highAlarm(1),
|
||||
highWarning(2),
|
||||
lowWarning(3),
|
||||
lowAlarm(4)
|
||||
}
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the threshold type."
|
||||
::= { dDdmThresholdCfgEntry 2 }
|
||||
|
||||
dDdmThresholdCfgValue OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the configured threshold. The value is
|
||||
interpreted within the context of dDdmThresholdComponent and
|
||||
dDmThresholdAbnormalLevel in the same row. The unit and valid range
|
||||
are as follows:
|
||||
Threshold Type Unit Valid Range
|
||||
============= ===================== =================
|
||||
Temperature milli-degrees Celsius -128,000 ~ 127,996
|
||||
voltage centi-Volt 0 ~ 655
|
||||
biasCurrent milli-amperes 0 ~ 131
|
||||
txPowerMw tenths of a microwatt 0 ~ 65,535
|
||||
txPowerDbm ten-thousandths of DBM -400,000 ~ 81,647
|
||||
rxPowerMw tenths of a microwatt 0 ~ 65,535
|
||||
rxPowerDbm ten-thousandths of DBM -400,000 ~ 81,647
|
||||
"
|
||||
::= { dDdmThresholdCfgEntry 3 }
|
||||
|
||||
dDdmThresholdCfgRowStatus OBJECT-TYPE
|
||||
SYNTAX RowStatus
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The status of this conceptual row."
|
||||
::= { dDdmThresholdCfgEntry 4 }
|
||||
|
||||
-- --------------------------------------------------------------------------
|
||||
dDdmInfo OBJECT IDENTIFIER ::= { dDdmMIBObjects 4 }
|
||||
|
||||
dDdmIfInfoTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF DDdmIfInfoEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains a list of information about current operating
|
||||
parameters of interfaces. Only the applicable interfaces (i.e.SFP
|
||||
module with DDM capability is plugged-in. ) will appear in this table.
|
||||
Note:
|
||||
1. The threshold may be administratively configured or factory
|
||||
preset value defined by vendors. dDdmThresholdCfgTable provides
|
||||
the administrative threshold configuration.
|
||||
2. It doesn't necessarily means the DDM is enabled on the interface
|
||||
when an entry appears in this table. dDdmIfCfgTable provides such
|
||||
information."
|
||||
::= {dDdmInfo 1}
|
||||
|
||||
dDdmIfInfoEntry OBJECT-TYPE
|
||||
SYNTAX DDdmIfInfoEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry appears in this table contains current operating parameters
|
||||
for transceiver monitoring of a port."
|
||||
INDEX { ifIndex }
|
||||
::= { dDdmIfInfoTable 1}
|
||||
|
||||
DDdmIfInfoEntry ::=
|
||||
SEQUENCE {
|
||||
dDdmIfInfoCurrentTemperature Integer32,
|
||||
dDdmIfInfoTemperatureState DlinkThresholdState,
|
||||
dDdmIfInfoHighAlarmTemperature Integer32,
|
||||
dDdmIfInfoHighWarnTemperature Integer32,
|
||||
dDdmIfInfoLowWarnTemperature Integer32,
|
||||
dDdmIfInfoLowAlarmTemperature Integer32,
|
||||
dDdmIfInfoCurrentVoltage Integer32,
|
||||
dDdmIfInfoVoltageState DlinkThresholdState,
|
||||
dDdmIfInfoHighAlarmVoltage Integer32,
|
||||
dDdmIfInfoHighWarnVoltage Integer32,
|
||||
dDdmIfInfoLowWarnVoltage Integer32,
|
||||
dDdmIfInfoLowAlarmVoltage Integer32,
|
||||
dDdmIfInfoCurrentBiasCurrent Integer32,
|
||||
dDdmIfInfoBiasCurrentState DlinkThresholdState,
|
||||
dDdmIfInfoHighAlarmBiasCurrent Integer32,
|
||||
dDdmIfInfoHighWarnBiasCurrent Integer32,
|
||||
dDdmIfInfoLowWarnBiasCurrent Integer32,
|
||||
dDdmIfInfoLowAlarmBiasCurrent Integer32,
|
||||
dDdmIfInfoCurrentTxPower Integer32,
|
||||
dDdmIfInfoTxPowerState DlinkThresholdState,
|
||||
dDdmIfInfoHighAlarmTxPower Integer32,
|
||||
dDdmIfInfoHighWarnTxPower Integer32,
|
||||
dDdmIfInfoLowWarnTxPower Integer32,
|
||||
dDdmIfInfoLowAlarmTxPower Integer32,
|
||||
dDdmIfInfoCurrentRxPower Integer32,
|
||||
dDdmIfInfoRxPowerState DlinkThresholdState,
|
||||
dDdmIfInfoHighAlarmRxPower Integer32,
|
||||
dDdmIfInfoHighWarnRxPower Integer32,
|
||||
dDdmIfInfoLowWarnRxPower Integer32,
|
||||
dDdmIfInfoLowAlarmRxPower Integer32
|
||||
}
|
||||
|
||||
dDdmIfInfoCurrentTemperature OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "milli-degrees Celsius"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the current temperature in unit of
|
||||
'milli-degrees Celsius' on the interface."
|
||||
::= { dDdmIfInfoEntry 1 }
|
||||
|
||||
dDdmIfInfoTemperatureState OBJECT-TYPE
|
||||
SYNTAX DlinkThresholdState
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the state of current temperature."
|
||||
::= { dDdmIfInfoEntry 2 }
|
||||
|
||||
dDdmIfInfoHighAlarmTemperature OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "milli-degrees Celsius"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the high alarm threshold, when the operating
|
||||
temperature rises above this value, it indicates an alarm status.
|
||||
The value is in unit of 'milli-degrees Celsius'."
|
||||
::= { dDdmIfInfoEntry 3 }
|
||||
|
||||
|
||||
dDdmIfInfoHighWarnTemperature OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "milli-degrees Celsius"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the high warning threshold, when the operating
|
||||
temperature rises above this value, it indicates a warning status.
|
||||
The value is in unit of 'milli-degrees Celsius'."
|
||||
::= { dDdmIfInfoEntry 4 }
|
||||
|
||||
dDdmIfInfoLowWarnTemperature OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "milli-degrees Celsius"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the low warning threshold, when the operating
|
||||
temperature falls below this value, it indicates a warning status.
|
||||
The value is in unit of 'milli-degrees Celsius'."
|
||||
::= { dDdmIfInfoEntry 5 }
|
||||
|
||||
dDdmIfInfoLowAlarmTemperature OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "milli-degrees Celsius"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the low alarm threshold, when the operating
|
||||
temperature falls below this value, it indicates an alarm status.
|
||||
The value is in unit of 'milli-degrees Celsius'."
|
||||
::= { dDdmIfInfoEntry 6 }
|
||||
|
||||
dDdmIfInfoCurrentVoltage OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "centi-Volt"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the current voltage in unit of
|
||||
'centi-Volt' on the interface."
|
||||
::= { dDdmIfInfoEntry 7 }
|
||||
|
||||
dDdmIfInfoVoltageState OBJECT-TYPE
|
||||
SYNTAX DlinkThresholdState
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the state of current voltage."
|
||||
::= { dDdmIfInfoEntry 8 }
|
||||
|
||||
dDdmIfInfoHighAlarmVoltage OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "centi-Volt"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the high alarm threshold, when the operating
|
||||
voltage rises above this value, it indicates an alarm status.
|
||||
The value is in unit of 'centi-Volt'."
|
||||
::= { dDdmIfInfoEntry 9 }
|
||||
|
||||
dDdmIfInfoHighWarnVoltage OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "centi-Volt"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the high warning threshold, when the operating
|
||||
voltage rises above this value, it indicates a warning status.
|
||||
The value is in unit of 'centi-Volt'."
|
||||
::= { dDdmIfInfoEntry 10 }
|
||||
|
||||
dDdmIfInfoLowWarnVoltage OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "centi-Volt"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the low warning threshold, when the operating
|
||||
voltage falls below this value, it indicates a warning status.
|
||||
The value is in unit of 'centi-Volt'."
|
||||
::= { dDdmIfInfoEntry 11 }
|
||||
|
||||
dDdmIfInfoLowAlarmVoltage OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "centi-Volt"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the low alarm threshold, when the operating
|
||||
voltage falls below this value, it indicates an alarm status.
|
||||
The value is in unit of 'centi-Volt'."
|
||||
::= { dDdmIfInfoEntry 12 }
|
||||
|
||||
dDdmIfInfoCurrentBiasCurrent OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "milli-amperes"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the current bias current in unit of
|
||||
'milli-amperes' on the interface."
|
||||
::= { dDdmIfInfoEntry 13 }
|
||||
|
||||
dDdmIfInfoBiasCurrentState OBJECT-TYPE
|
||||
SYNTAX DlinkThresholdState
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the state of current BiasCurrent."
|
||||
::= { dDdmIfInfoEntry 14 }
|
||||
|
||||
dDdmIfInfoHighAlarmBiasCurrent OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "milli-amperes"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the high alarm threshold, when the operating
|
||||
bias current rises above this value, it indicates an alarm status.
|
||||
The value is in unit of 'milli-amperes'."
|
||||
::= { dDdmIfInfoEntry 15 }
|
||||
|
||||
dDdmIfInfoHighWarnBiasCurrent OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "milli-amperes"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the high warning threshold, when the operating
|
||||
bias current rises above this value, it indicates a warning status.
|
||||
The value is in unit of 'milli-amperes'."
|
||||
::= { dDdmIfInfoEntry 16 }
|
||||
|
||||
dDdmIfInfoLowWarnBiasCurrent OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "milli-amperes"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the low warning threshold, when the operating
|
||||
bias current falls below this value, it indicates a warning status.
|
||||
The value is in unit of 'milli-amperes'."
|
||||
::= { dDdmIfInfoEntry 17 }
|
||||
|
||||
dDdmIfInfoLowAlarmBiasCurrent OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "milli-amperes"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the low alarm threshold, when the operating
|
||||
bias current falls below this value, it indicates an alarm status.
|
||||
The value is in unit of 'milli-amperes'."
|
||||
::= { dDdmIfInfoEntry 18 }
|
||||
|
||||
dDdmIfInfoCurrentTxPower OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "tenths of a microwatt"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the current output power in unit of
|
||||
'tenths of a microwatt' on the interface."
|
||||
::= { dDdmIfInfoEntry 19 }
|
||||
|
||||
dDdmIfInfoTxPowerState OBJECT-TYPE
|
||||
SYNTAX DlinkThresholdState
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the state of current output power."
|
||||
::= { dDdmIfInfoEntry 20 }
|
||||
|
||||
dDdmIfInfoHighAlarmTxPower OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "tenths of a microwatt"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the high alarm threshold, when the operating
|
||||
output power rises above this value, it indicates an alarm status.
|
||||
The value is in unit of 'tenths of a microwatt'."
|
||||
::= { dDdmIfInfoEntry 21 }
|
||||
|
||||
dDdmIfInfoHighWarnTxPower OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "tenths of a microwatt"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the high warning threshold, when the operating
|
||||
output power rises above this value, it indicates a warning status.
|
||||
The value is in unit of 'tenths of a microwatt'."
|
||||
::= { dDdmIfInfoEntry 22 }
|
||||
|
||||
dDdmIfInfoLowWarnTxPower OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "tenths of a microwatt"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the low warning threshold, when the operating
|
||||
output power falls below this value, it indicates a warning status.
|
||||
The value is in unit of 'tenths of a microwatt'."
|
||||
::= { dDdmIfInfoEntry 23 }
|
||||
|
||||
dDdmIfInfoLowAlarmTxPower OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "tenths of a microwatt"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the low alarm threshold, when the operating
|
||||
output power falls below this value, it indicates an alarm status.
|
||||
The value is in unit of 'tenths of a microwatt'."
|
||||
::= { dDdmIfInfoEntry 24 }
|
||||
|
||||
dDdmIfInfoCurrentRxPower OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "tenths of a microwatt"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the current input power in unit of
|
||||
'tenths of a microwatt' on the interface."
|
||||
::= { dDdmIfInfoEntry 25 }
|
||||
|
||||
dDdmIfInfoRxPowerState OBJECT-TYPE
|
||||
SYNTAX DlinkThresholdState
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the state of current input power."
|
||||
::= { dDdmIfInfoEntry 26 }
|
||||
|
||||
dDdmIfInfoHighAlarmRxPower OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "tenths of a microwatt"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the high alarm threshold, when the operating
|
||||
input power rises above this value, it indicates an alarm status.
|
||||
The value is in unit of 'tenths of a microwatt'."
|
||||
::= { dDdmIfInfoEntry 27 }
|
||||
|
||||
dDdmIfInfoHighWarnRxPower OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "tenths of a microwatt"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the high warning threshold, when the operating
|
||||
input power rises above this value, it indicates a warning status.
|
||||
The value is in unit of 'tenths of a microwatt'."
|
||||
::= { dDdmIfInfoEntry 28 }
|
||||
|
||||
dDdmIfInfoLowWarnRxPower OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "tenths of a microwatt"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the low warning threshold, when the operating
|
||||
input power falls below this value, it indicates a warning status.
|
||||
The value is in unit of 'tenths of a microwatt'."
|
||||
::= { dDdmIfInfoEntry 29 }
|
||||
|
||||
dDdmIfInfoLowAlarmRxPower OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "tenths of a microwatt"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the low alarm threshold, when the operating
|
||||
input power falls below this value, it indicates an alarm status.
|
||||
The value is in unit of 'tenths of a microwatt'."
|
||||
::= { dDdmIfInfoEntry 30 }
|
||||
|
||||
-- --------------------------------------------------------------------------
|
||||
dDdmNotifyInfo OBJECT IDENTIFIER ::= { dDdmMIBObjects 5 }
|
||||
|
||||
dDdmNotifyInfoIfIndex OBJECT-TYPE
|
||||
SYNTAX InterfaceIndex
|
||||
MAX-ACCESS accessible-for-notify
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used by dDdmAlarmTrap and dDdmWarningTrap to indicate
|
||||
the ifIndex on which the monitoring value rises above or falls below
|
||||
the corresponding threshold."
|
||||
::= { dDdmNotifyInfo 1 }
|
||||
|
||||
dDdmNotifyInfoComponent OBJECT-TYPE
|
||||
SYNTAX INTEGER{
|
||||
temperature(1),
|
||||
voltage(2),
|
||||
biasCurrent(3),
|
||||
txPowerMw(4),
|
||||
rxPowerMw(5)
|
||||
}
|
||||
MAX-ACCESS accessible-for-notify
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used by dDdmAlarmTrap and dDdmWarningTrap to indicate
|
||||
the abnormal component."
|
||||
::= { dDdmNotifyInfo 2 }
|
||||
|
||||
dDdmNotifyInfoAbnormalLevel OBJECT-TYPE
|
||||
SYNTAX INTEGER{
|
||||
high(1),
|
||||
low(2)
|
||||
}
|
||||
MAX-ACCESS accessible-for-notify
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used by dDdmAlarmTrap and dDdmWarningTrap to indicate
|
||||
the abnormal level."
|
||||
::= { dDdmNotifyInfo 3 }
|
||||
|
||||
dDdmNotifyInfoThresholdExceedOrRecover OBJECT-TYPE
|
||||
SYNTAX INTEGER{
|
||||
exceed(1),
|
||||
recover(2)
|
||||
}
|
||||
MAX-ACCESS accessible-for-notify
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used by dDdmAlarmTrap and dDdmWarningTrap to indicate the
|
||||
GBIC is exceeding its threshold or recover to
|
||||
normal status."
|
||||
::= {dDdmNotifyInfo 4}
|
||||
|
||||
|
||||
-- --------------------------------------------------------------------------
|
||||
|
||||
dDdmAlarmTrap NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
dDdmNotifyInfoIfIndex,
|
||||
dDdmNotifyInfoComponent,
|
||||
dDdmNotifyInfoAbnormalLevel,
|
||||
dDdmNotifyInfoThresholdExceedOrRecover
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The trap is sent when dDdmNotifyEnable is 'true' and an abnormal
|
||||
alarm situation occurs or recovers from an abnormal alarm situation
|
||||
to normal status."
|
||||
::= { dDdmMIBNotifications 1 }
|
||||
|
||||
dDdmWarningTrap NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
dDdmNotifyInfoIfIndex,
|
||||
dDdmNotifyInfoComponent,
|
||||
dDdmNotifyInfoAbnormalLevel,
|
||||
dDdmNotifyInfoThresholdExceedOrRecover
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The trap is sent when dDdmNotifyEnable is 'true' and an abnormal
|
||||
warning situation occurs or recovers from an abnormal warning
|
||||
situation to normal status."
|
||||
::= { dDdmMIBNotifications 2 }
|
||||
|
||||
-- ***************************************************************************
|
||||
-- Conformance
|
||||
-- ***************************************************************************
|
||||
dDdmCompliances OBJECT IDENTIFIER ::= { dDdmMIBConformance 1 }
|
||||
|
||||
dDdmCompliance MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The compliance statement for entities which implement the
|
||||
DLINKSW-DDM-MIB."
|
||||
MODULE -- this module
|
||||
MANDATORY-GROUPS {
|
||||
dDdmInfoGroup,
|
||||
dDdmCfgGroup,
|
||||
dDdmNotifyGroup
|
||||
}
|
||||
::= { dDdmCompliances 1 }
|
||||
|
||||
dDdmGroups OBJECT IDENTIFIER ::= { dDdmMIBConformance 2 }
|
||||
|
||||
dDdmInfoGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
dDdmIfInfoCurrentTemperature, dDdmIfInfoTemperatureState,
|
||||
dDdmIfInfoHighAlarmTemperature, dDdmIfInfoHighWarnTemperature,
|
||||
dDdmIfInfoLowWarnTemperature, dDdmIfInfoLowAlarmTemperature,
|
||||
dDdmIfInfoCurrentVoltage, dDdmIfInfoVoltageState,
|
||||
dDdmIfInfoHighAlarmVoltage, dDdmIfInfoHighWarnVoltage,
|
||||
dDdmIfInfoLowWarnVoltage, dDdmIfInfoLowAlarmVoltage,
|
||||
dDdmIfInfoCurrentBiasCurrent, dDdmIfInfoBiasCurrentState,
|
||||
dDdmIfInfoHighAlarmBiasCurrent, dDdmIfInfoHighWarnBiasCurrent,
|
||||
dDdmIfInfoLowWarnBiasCurrent, dDdmIfInfoLowAlarmBiasCurrent,
|
||||
dDdmIfInfoCurrentTxPower, dDdmIfInfoTxPowerState,
|
||||
dDdmIfInfoHighAlarmTxPower, dDdmIfInfoHighWarnTxPower,
|
||||
dDdmIfInfoLowWarnTxPower, dDdmIfInfoLowAlarmTxPower,
|
||||
dDdmIfInfoCurrentRxPower, dDdmIfInfoRxPowerState,
|
||||
dDdmIfInfoHighAlarmRxPower, dDdmIfInfoHighWarnRxPower,
|
||||
dDdmIfInfoLowWarnRxPower, dDdmIfInfoLowAlarmRxPower,
|
||||
dDdmNotifyInfoIfIndex, dDdmNotifyInfoComponent,
|
||||
dDdmNotifyInfoAbnormalLevel,
|
||||
dDdmNotifyInfoThresholdExceedOrRecover
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of objects provides DDM operating information."
|
||||
::= { dDdmGroups 1 }
|
||||
|
||||
dDdmCfgGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
dDdmNotifyEnable,
|
||||
dDdmIfCfgEnabled, dDdmShutdownLevel,
|
||||
dDdmThresholdCfgValue, dDdmThresholdCfgRowStatus
|
||||
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of objects provides DDM configuration."
|
||||
::= { dDdmGroups 2 }
|
||||
|
||||
dDdmNotifyGroup NOTIFICATION-GROUP
|
||||
NOTIFICATIONS {
|
||||
dDdmAlarmTrap,
|
||||
dDdmWarningTrap
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The collection of notifications used for DDM."
|
||||
::= { dDdmGroups 3 }
|
||||
|
||||
END
|