RADLAN-HWENVIROMENT DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
rnd FROM RADLAN-MIB
|
||||
MODULE-IDENTITY, OBJECT-TYPE FROM SNMPv2-SMI
|
||||
TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC;
|
||||
|
||||
rlEnv MODULE-IDENTITY
|
||||
LAST-UPDATED "200309210000Z"
|
||||
ORGANIZATION "Radlan Computer Communications Ltd."
|
||||
CONTACT-INFO
|
||||
"radlan.com"
|
||||
DESCRIPTION
|
||||
"The private MIB module definition for environment of Radlan devices."
|
||||
REVISION "200309210000Z"
|
||||
DESCRIPTION
|
||||
"Added this MODULE-IDENTITY clause."
|
||||
::= { rnd 83 }
|
||||
|
||||
RlEnvMonState ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Represents the state of a device being monitored.
|
||||
Valid values are:
|
||||
|
||||
normal(1): the environment is good, such as low
|
||||
temperature or full battery charge.
|
||||
|
||||
warning(2): the environment is bad, such as temperature
|
||||
above normal operation range but not too
|
||||
high, or battery discharge.
|
||||
|
||||
critical(3): the environment is very bad, such as
|
||||
temperature much higher than normal
|
||||
operation limit or critically low battery charge.
|
||||
|
||||
shutdown(4): the environment is the worst, the system
|
||||
should be shutdown immediately.
|
||||
|
||||
notPresent(5): the environmental monitor is not present,
|
||||
such as temperature sensors or battery does not
|
||||
exist.
|
||||
|
||||
notFunctioning(6): the environmental monitor does not
|
||||
function properly, such as a temperature
|
||||
sensor generates a abnormal data like
|
||||
1000 C or error happens while reading battery
|
||||
state.
|
||||
|
||||
restore(7): the environment is restoring its normal state,
|
||||
such as battery recharging.
|
||||
"
|
||||
SYNTAX INTEGER {
|
||||
normal(1),
|
||||
warning(2),
|
||||
critical(3),
|
||||
shutdown(4),
|
||||
notPresent(5),
|
||||
notFunctioning(6),
|
||||
restore(7)
|
||||
}
|
||||
|
||||
|
||||
rlEnvPhysicalDescription OBJECT IDENTIFIER ::= { rlEnv 1 }
|
||||
|
||||
rlEnvMonFanStatusTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlEnvMonFanStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table of fan status maintained by the environmental
|
||||
monitor."
|
||||
::= { rlEnvPhysicalDescription 1 }
|
||||
|
||||
rlEnvMonFanStatusEntry OBJECT-TYPE
|
||||
SYNTAX RlEnvMonFanStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the fan status table, representing the status of
|
||||
the associated fan maintained by the environmental monitor."
|
||||
INDEX { rlEnvMonFanStatusIndex }
|
||||
::= { rlEnvMonFanStatusTable 1 }
|
||||
|
||||
RlEnvMonFanStatusEntry ::=
|
||||
SEQUENCE {
|
||||
rlEnvMonFanStatusIndex INTEGER,
|
||||
rlEnvMonFanStatusDescr DisplayString,
|
||||
rlEnvMonFanState RlEnvMonState
|
||||
}
|
||||
|
||||
rlEnvMonFanStatusIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unique index for the fan being instrumented.
|
||||
This index is for SNMP purposes only, and has no
|
||||
intrinsic meaning."
|
||||
::= { rlEnvMonFanStatusEntry 1 }
|
||||
|
||||
rlEnvMonFanStatusDescr OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..32))
|
||||
MAX-ACCESS read-only
|
||||
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Textual description of the fan being instrumented.
|
||||
This description is a short textual label, suitable as a
|
||||
human-sensible identification for the rest of the
|
||||
information in the entry."
|
||||
::= { rlEnvMonFanStatusEntry 2 }
|
||||
|
||||
rlEnvMonFanState OBJECT-TYPE
|
||||
SYNTAX RlEnvMonState
|
||||
MAX-ACCESS read-only
|
||||
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The mandatory state of the fan being instrumented."
|
||||
::= { rlEnvMonFanStatusEntry 3 }
|
||||
|
||||
|
||||
|
||||
rlEnvMonSupplyStatusTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlEnvMonSupplyStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table of power supply status maintained by the
|
||||
environmental monitor card."
|
||||
::= { rlEnvPhysicalDescription 2 }
|
||||
|
||||
rlEnvMonSupplyStatusEntry OBJECT-TYPE
|
||||
SYNTAX RlEnvMonSupplyStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the power supply status table, representing the
|
||||
status of the associated power supply maintained by the
|
||||
environmental monitor card."
|
||||
INDEX { rlEnvMonSupplyStatusIndex }
|
||||
::= { rlEnvMonSupplyStatusTable 1 }
|
||||
|
||||
RlEnvMonSupplyStatusEntry ::=
|
||||
SEQUENCE {
|
||||
rlEnvMonSupplyStatusIndex INTEGER ,
|
||||
rlEnvMonSupplyStatusDescr DisplayString,
|
||||
rlEnvMonSupplyState RlEnvMonState,
|
||||
rlEnvMonSupplySource INTEGER
|
||||
}
|
||||
|
||||
rlEnvMonSupplyStatusIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..2147483647)
|
||||
MAX-ACCESS not-accessible
|
||||
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unique index for the power supply being instrumented.
|
||||
This index is for SNMP purposes only, and has no
|
||||
intrinsic meaning."
|
||||
::= { rlEnvMonSupplyStatusEntry 1 }
|
||||
|
||||
rlEnvMonSupplyStatusDescr OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..32))
|
||||
MAX-ACCESS read-only
|
||||
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Textual description of the power supply being instrumented.
|
||||
This description is a short textual label, suitable as a
|
||||
human-sensible identification for the rest of the
|
||||
information in the entry."
|
||||
::= { rlEnvMonSupplyStatusEntry 2 }
|
||||
|
||||
rlEnvMonSupplyState OBJECT-TYPE
|
||||
SYNTAX RlEnvMonState
|
||||
MAX-ACCESS read-only
|
||||
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The mandatory state of the power supply being instrumented."
|
||||
::= { rlEnvMonSupplyStatusEntry 3 }
|
||||
|
||||
rlEnvMonSupplySource OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
unknown(1),
|
||||
ac(2),
|
||||
dc(3),
|
||||
externalPowerSupply(4),
|
||||
internalRedundant(5)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The power supply source.
|
||||
unknown - Power supply source unknown
|
||||
ac - AC power supply
|
||||
dc - DC power supply
|
||||
externalPowerSupply - External power supply
|
||||
internalRedundant - Internal redundant power supply
|
||||
"
|
||||
::= { rlEnvMonSupplyStatusEntry 4 }
|
||||
|
||||
|
||||
rlEnvMonIndexTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlEnvMonIndexEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table that can help building indexes for EnvMon tables."
|
||||
::= { rlEnvPhysicalDescription 10 }
|
||||
|
||||
rlEnvMonIndexEntry OBJECT-TYPE
|
||||
SYNTAX RlEnvMonIndexEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in table, representing the index input parameters."
|
||||
INDEX { rlEnvMonIndexUnitId, rlEnvMonIndexObjType, rlEnvMonIndexObjIndex }
|
||||
::= { rlEnvMonIndexTable 1 }
|
||||
|
||||
RlEnvMonIndexEntry ::=
|
||||
SEQUENCE {
|
||||
rlEnvMonIndexUnitId INTEGER,
|
||||
rlEnvMonIndexObjType INTEGER,
|
||||
rlEnvMonIndexObjIndex INTEGER,
|
||||
rlEnvMonIndexValue INTEGER
|
||||
}
|
||||
|
||||
rlEnvMonIndexUnitId OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unit ID."
|
||||
::= { rlEnvMonIndexEntry 1 }
|
||||
|
||||
rlEnvMonIndexObjType OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
powerSupply(5),
|
||||
fan(6),
|
||||
thermalSensorUnderCard(14)
|
||||
}
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Object type."
|
||||
::= { rlEnvMonIndexEntry 2 }
|
||||
|
||||
rlEnvMonIndexObjIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Index of object."
|
||||
::= { rlEnvMonIndexEntry 3 }
|
||||
|
||||
rlEnvMonIndexValue OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Calculated index value."
|
||||
::= { rlEnvMonIndexEntry 4 }
|
||||
|
||||
|
||||
|
||||
rlEnvFanData OBJECT IDENTIFIER ::= { rlEnv 5 }
|
||||
|
||||
rlEnvFanDataTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlEnvFanDataEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"For each unit in a stack"
|
||||
::= { rlEnvFanData 1 }
|
||||
|
||||
rlEnvFanDataEntry OBJECT-TYPE
|
||||
SYNTAX RlEnvFanDataEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry of this table specifies a unit"
|
||||
INDEX { rlEnvFanDataStackUnit }
|
||||
::= { rlEnvFanDataTable 1 }
|
||||
|
||||
RlEnvFanDataEntry ::= SEQUENCE {
|
||||
rlEnvFanDataStackUnit INTEGER,
|
||||
rlEnvFanDataTemp INTEGER,
|
||||
rlEnvFanDataSpeed INTEGER,
|
||||
rlEnvFanDataOperLevel INTEGER,
|
||||
rlEnvFanDataAdminLevel INTEGER
|
||||
}
|
||||
|
||||
rlEnvFanDataStackUnit OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The number of the stack unit"
|
||||
::= { rlEnvFanDataEntry 1 }
|
||||
|
||||
rlEnvFanDataTemp OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The unit temperature"
|
||||
::= { rlEnvFanDataEntry 2 }
|
||||
|
||||
rlEnvFanDataSpeed OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Fan speed in RPM"
|
||||
::= { rlEnvFanDataEntry 3 }
|
||||
|
||||
rlEnvFanDataOperLevel OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Fan speed operative level"
|
||||
::= { rlEnvFanDataEntry 4 }
|
||||
|
||||
rlEnvFanDataAdminLevel OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Configured fan speed level"
|
||||
::= { rlEnvFanDataEntry 5 }
|
||||
|
||||
|
||||
END
|
||||
|