RADLAN-PHY-MIB DEFINITIONS ::= BEGIN
 | 
			
		||||
 | 
			
		||||
-- Title:      RADLAN PHY MIB
 | 
			
		||||
-- Version:    7.38
 | 
			
		||||
-- Date:       10 Sep 2004
 | 
			
		||||
--
 | 
			
		||||
IMPORTS
 | 
			
		||||
    OBJECT-TYPE, MODULE-IDENTITY                FROM SNMPv2-SMI
 | 
			
		||||
    ifIndex                                     FROM IF-MIB
 | 
			
		||||
    TimeStamp, DisplayString                    FROM SNMPv2-TC
 | 
			
		||||
    rnd                                         FROM RADLAN-MIB
 | 
			
		||||
    TEXTUAL-CONVENTION                          FROM SNMPv2-TC;
 | 
			
		||||
 | 
			
		||||
   rlPhy MODULE-IDENTITY
 | 
			
		||||
      LAST-UPDATED "200209300024Z"  -- September 30, 2002
 | 
			
		||||
      ORGANIZATION "Radlan Computer Communication Ltd."
 | 
			
		||||
      CONTACT-INFO
 | 
			
		||||
              "radlan.com"
 | 
			
		||||
      DESCRIPTION
 | 
			
		||||
              "The MIB module describes the private MIB for testing Layer1 interfaces supported
 | 
			
		||||
               by Radlan's software and products."
 | 
			
		||||
      REVISION     "200209300024Z"  -- September 30, 2002
 | 
			
		||||
      DESCRIPTION
 | 
			
		||||
              "Initial revision"
 | 
			
		||||
      REVISION     "200309210024Z"  -- September 21, 2003
 | 
			
		||||
      DESCRIPTION
 | 
			
		||||
              "Added MODULE-IDENTITY and TEXTUAL-CONVENTION IMPORTS."
 | 
			
		||||
      ::= { rnd 90  }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
RlPhyTestType ::= TEXTUAL-CONVENTION
 | 
			
		||||
    STATUS          current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "A value indicating the test to perform."
 | 
			
		||||
   SYNTAX  INTEGER {
 | 
			
		||||
        rlPhyTestTableNoTest(1),
 | 
			
		||||
        rlPhyTestTableCableStatus(2),
 | 
			
		||||
        rlPhyTestTableCableFault(3),
 | 
			
		||||
        rlPhyTestTableCableLength(4),
 | 
			
		||||
        rlPhyTestTableTransceiverTemp(5),
 | 
			
		||||
        rlPhyTestTableTransceiverSupply(6),
 | 
			
		||||
        rlPhyTestTableTxBias(7),
 | 
			
		||||
        rlPhyTestTableTxOutput(8),
 | 
			
		||||
        rlPhyTestTableRxOpticalPower(9),
 | 
			
		||||
        rlPhyTestTableDataReady(10),
 | 
			
		||||
        rlPhyTestTableLOS(11),
 | 
			
		||||
        rlPhyTestTableTxFault(12),
 | 
			
		||||
        rlPhyTestTableCableChannel1(13),
 | 
			
		||||
        rlPhyTestTableCableChannel2(14),
 | 
			
		||||
        rlPhyTestTableCableChannel3(15),
 | 
			
		||||
        rlPhyTestTableCableChannel4(16),
 | 
			
		||||
        rlPhyTestTableCablePolarity1(17),
 | 
			
		||||
        rlPhyTestTableCablePolarity2(18),
 | 
			
		||||
        rlPhyTestTableCablePolarity3(19),
 | 
			
		||||
        rlPhyTestTableCablePolarity4(20),
 | 
			
		||||
        rlPhyTestTableCablePairSkew1(21),
 | 
			
		||||
        rlPhyTestTableCablePairSkew2(22),
 | 
			
		||||
        rlPhyTestTableCablePairSkew3(23),
 | 
			
		||||
        rlPhyTestTableCablePairSkew4(24),
 | 
			
		||||
        rlPhyTestTableCableStatusFast(25)
 | 
			
		||||
    }
 | 
			
		||||
 | 
			
		||||
rlPhyTest OBJECT IDENTIFIER ::= { rlPhy 1 }
 | 
			
		||||
 | 
			
		||||
rlPhyTestSetTable   OBJECT-TYPE
 | 
			
		||||
    SYNTAX SEQUENCE OF RlPhyTestSetEntry
 | 
			
		||||
    MAX-ACCESS  not-accessible
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION ""
 | 
			
		||||
    ::= { rlPhyTest 1}
 | 
			
		||||
 | 
			
		||||
rlPhyTestSetEntry OBJECT-TYPE
 | 
			
		||||
    SYNTAX       RlPhyTestSetEntry
 | 
			
		||||
    MAX-ACCESS   not-accessible
 | 
			
		||||
    STATUS       current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "An entry containing objects for invoking tests on an interface."
 | 
			
		||||
    INDEX {ifIndex }
 | 
			
		||||
    ::= { rlPhyTestSetTable 1 }
 | 
			
		||||
 | 
			
		||||
RlPhyTestSetEntry ::=
 | 
			
		||||
    SEQUENCE {
 | 
			
		||||
        rlPhyTestSetType        RlPhyTestType
 | 
			
		||||
    }
 | 
			
		||||
 | 
			
		||||
rlPhyTestSetType       OBJECT-TYPE
 | 
			
		||||
    SYNTAX  RlPhyTestType
 | 
			
		||||
    MAX-ACCESS   read-write
 | 
			
		||||
    STATUS       current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "A control variable used to start operator initiated interface
 | 
			
		||||
             tests.1 indicates that no test has been initiated. Only
 | 
			
		||||
             operator initiated interface tests can be set to this variable."
 | 
			
		||||
              ::= { rlPhyTestSetEntry 1 }
 | 
			
		||||
 | 
			
		||||
rlPhyTestGetTable   OBJECT-TYPE
 | 
			
		||||
    SYNTAX      SEQUENCE OF RlPhyTestGetEntry
 | 
			
		||||
    MAX-ACCESS  not-accessible
 | 
			
		||||
    STATUS      current
 | 
			
		||||
    DESCRIPTION ""
 | 
			
		||||
    ::= { rlPhyTest 2 }
 | 
			
		||||
 | 
			
		||||
rlPhyTestGetEntry OBJECT-TYPE
 | 
			
		||||
    SYNTAX       RlPhyTestGetEntry
 | 
			
		||||
    MAX-ACCESS   not-accessible
 | 
			
		||||
    STATUS       current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "An entry containing results of tests on an interface."
 | 
			
		||||
    INDEX {ifIndex, rlPhyTestGetType}
 | 
			
		||||
    ::= { rlPhyTestGetTable 1 }
 | 
			
		||||
 | 
			
		||||
RlPhyTestGetEntry ::=
 | 
			
		||||
    SEQUENCE {
 | 
			
		||||
        rlPhyTestGetType        RlPhyTestType,
 | 
			
		||||
        rlPhyTestGetStatus      INTEGER,
 | 
			
		||||
        rlPhyTestGetResult      INTEGER,
 | 
			
		||||
        rlPhyTestGetUnits       INTEGER,
 | 
			
		||||
        rlPhyTestGetAlarm       INTEGER,
 | 
			
		||||
        rlPhyTestGetTimeStamp   DisplayString
 | 
			
		||||
    }
 | 
			
		||||
 | 
			
		||||
rlPhyTestGetType       OBJECT-TYPE
 | 
			
		||||
    SYNTAX     RlPhyTestType
 | 
			
		||||
    MAX-ACCESS read-only
 | 
			
		||||
    STATUS     current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "A control variable used to, 1 to indicate that this test can be
 | 
			
		||||
            done on the specified port, 2 to initiate the test whenever the
 | 
			
		||||
            user wishes"
 | 
			
		||||
              ::= { rlPhyTestGetEntry 1 }
 | 
			
		||||
 | 
			
		||||
rlPhyTestGetStatus  OBJECT-TYPE
 | 
			
		||||
    SYNTAX       INTEGER {
 | 
			
		||||
        none(1),          -- no test yet requested
 | 
			
		||||
        success(2),
 | 
			
		||||
        inProgress(3),
 | 
			
		||||
        notSupported(4),
 | 
			
		||||
        unAbleToRun(5),   -- due to state of system
 | 
			
		||||
        aborted(6),
 | 
			
		||||
        failed(7)
 | 
			
		||||
                 }
 | 
			
		||||
    MAX-ACCESS   read-only
 | 
			
		||||
    STATUS       current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "This object contains the status of the most recently
 | 
			
		||||
        requested test for operator initiated tests or the value
 | 
			
		||||
        none(1) if no tests have been requested since the last
 | 
			
		||||
        reset. For non operator initiated tests the value is always
 | 
			
		||||
        none(1).
 | 
			
		||||
        Note that this facility provides no provision for saving
 | 
			
		||||
        the results of one test when starting another, as could
 | 
			
		||||
        be required if used by multiple managers concurrently."
 | 
			
		||||
    ::= { rlPhyTestGetEntry 2 }
 | 
			
		||||
 | 
			
		||||
rlPhyTestGetResult  OBJECT-TYPE
 | 
			
		||||
    SYNTAX       INTEGER
 | 
			
		||||
    MAX-ACCESS   read-only
 | 
			
		||||
    STATUS       current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
            "This object holds the test result"
 | 
			
		||||
    ::= { rlPhyTestGetEntry 3 }
 | 
			
		||||
 | 
			
		||||
rlPhyTestGetUnits   OBJECT-TYPE
 | 
			
		||||
   SYNTAX  INTEGER {
 | 
			
		||||
        integer(1),
 | 
			
		||||
        boolean(2),
 | 
			
		||||
        downUP(3),
 | 
			
		||||
        reverseNormal(4),
 | 
			
		||||
        mdiMdix(5),
 | 
			
		||||
        meter(6),
 | 
			
		||||
        degree(7),  -- Celsius
 | 
			
		||||
        microVolt(8),
 | 
			
		||||
        microOham(9),
 | 
			
		||||
        microAmper(10),
 | 
			
		||||
        microWatt(11),
 | 
			
		||||
        millisecond(12),
 | 
			
		||||
        alaskaPhyLength(13),
 | 
			
		||||
        alaskaPhyStatus(14),
 | 
			
		||||
        dbm(15),
 | 
			
		||||
        decidbm(16),
 | 
			
		||||
        milidbm(17),
 | 
			
		||||
        abcd(18),
 | 
			
		||||
        nanosecond(19)
 | 
			
		||||
            }
 | 
			
		||||
    MAX-ACCESS   read-only
 | 
			
		||||
    STATUS       current
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "The test result unit of measure. The units can be standard unit or special units
 | 
			
		||||
         that are designed for special test.
 | 
			
		||||
 | 
			
		||||
         The alaskaPhyLength unit is design for the VCT diagnostic and its values are:
 | 
			
		||||
         less_than_50M(1), 50-80M(2), 80-110M(3), 110-140M(4), more_than_140M(5).
 | 
			
		||||
 | 
			
		||||
         The alaskaPhyStatus unit is design for the VCT diagnostic and its values are:
 | 
			
		||||
         4_pair_cable(1), 2_pair_cable(2), no_cable(3), open_cable(4), short_cable(5), bad_cable(6), impedance_mismatch(7)."
 | 
			
		||||
   ::= { rlPhyTestGetEntry 4 }
 | 
			
		||||
 | 
			
		||||
rlPhyTestGetAlarm   OBJECT-TYPE
 | 
			
		||||
   SYNTAX  INTEGER {
 | 
			
		||||
        notRelevant(1),
 | 
			
		||||
        noAlarmSet(2),
 | 
			
		||||
        lowWarning(3),
 | 
			
		||||
        highWarning(4),
 | 
			
		||||
        lowAlarm(5),
 | 
			
		||||
        highAlarm(6)
 | 
			
		||||
   }
 | 
			
		||||
   MAX-ACCESS   read-only
 | 
			
		||||
   STATUS       current
 | 
			
		||||
   DESCRIPTION
 | 
			
		||||
        "This object hold the Alarm for this Entry. only Test that have can have alarms
 | 
			
		||||
          use this field, other holds the Value notRelevant(1) "
 | 
			
		||||
   ::= { rlPhyTestGetEntry 5 }
 | 
			
		||||
 | 
			
		||||
rlPhyTestGetTimeStamp   OBJECT-TYPE
 | 
			
		||||
   SYNTAX  DisplayString (SIZE(1..32))
 | 
			
		||||
   MAX-ACCESS   read-only
 | 
			
		||||
   STATUS       current
 | 
			
		||||
   DESCRIPTION
 | 
			
		||||
        "The time in string (formated DD-MMM-YYYY HH:MM:SS e.g
 | 
			
		||||
         14-Apr-2002 10:33:31)"
 | 
			
		||||
    ::= { rlPhyTestGetEntry 6 }
 | 
			
		||||
 | 
			
		||||
END
 | 
			
		||||