Initial commit
This commit is contained in:
913
MIBS/enterasys/CTRON-POWER-SUPPLY-MIB
Normal file
913
MIBS/enterasys/CTRON-POWER-SUPPLY-MIB
Normal file
@ -0,0 +1,913 @@
|
||||
CTRON-POWER-SUPPLY-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
-- ctron-power-supply-mib.txt The power supply MIB
|
||||
-- Revision: 1.01.02
|
||||
-- Part Number:
|
||||
-- Date: March 26, 1997
|
||||
|
||||
-- Cabletron Systems, Inc.
|
||||
-- 35 Industrial Way, P.O. Box 5005
|
||||
-- Rochester, NH 03867-0505
|
||||
-- (603) 332-9400
|
||||
-- support@ctron.com
|
||||
|
||||
-- This module provides authoritative definitions for Cabletron's
|
||||
-- enterprise-specific chassis MIB.
|
||||
--
|
||||
-- This module will be extended, as needed.
|
||||
--
|
||||
|
||||
-- Cabletron Systems reserves the right to make changes in
|
||||
-- specification and other information contained in this document
|
||||
-- without prior notice. The reader should consult Cabletron Systems
|
||||
-- to determine whether any such changes have been made.
|
||||
--
|
||||
-- In no event shall Cabletron Systems be liable for any incidental,
|
||||
-- indirect, special, or consequential damages whatsoever (including
|
||||
-- but not limited to lost profits) arising out of or related to this
|
||||
-- document or the information contained in it, even if Cabletron
|
||||
-- Systems has been advised of, known, or should have known, the
|
||||
-- possibility of such damages.
|
||||
--
|
||||
-- Cabletron grants vendors, end-users, and other interested parties
|
||||
-- a non-exclusive license to use this Specification in connection
|
||||
-- with the management of Cabletron products.
|
||||
|
||||
-- Copyright August 95 Cabletron Systems
|
||||
|
||||
|
||||
-- This MIB describes objects for MMAC+ style power supplies.
|
||||
|
||||
IMPORTS
|
||||
ctps
|
||||
FROM CTRON-MIB-NAMES
|
||||
OBJECT-TYPE
|
||||
FROM RFC-1212;
|
||||
|
||||
|
||||
|
||||
--=============== group definitions ===================
|
||||
|
||||
chPower OBJECT IDENTIFIER ::= { ctps 1 }
|
||||
boardPower OBJECT IDENTIFIER ::= { ctps 2 }
|
||||
psPower OBJECT IDENTIFIER ::= { ctps 3 }
|
||||
bbuPower OBJECT IDENTIFIER ::= { ctps 4 }
|
||||
termPower OBJECT IDENTIFIER ::= { ctps 5 }
|
||||
|
||||
--=============== chPower group ====================
|
||||
|
||||
-- Chassis Power Group
|
||||
-- Implementation of the Chassis Power group is optional.
|
||||
-- It needs to be supported when an EM is present and operational
|
||||
-- in the chassis.
|
||||
-- This group covers information on the chassis power available.
|
||||
|
||||
chPowerOperationalStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
powerAC(1),
|
||||
powerACRedundant(2),
|
||||
powerDC(3),
|
||||
powerDCRedundant(4),
|
||||
battery(5)
|
||||
}
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This object reflects the overall status of the chassis's
|
||||
power supply in terms of how the power is being delivered
|
||||
to the chassis."
|
||||
::= { chPower 1 }
|
||||
|
||||
chPowerMainVoltageStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
powerOK(1),
|
||||
overCurrent(2),
|
||||
overVoltage(3),
|
||||
underVoltage(4)
|
||||
}
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This object reflects the state of the main voltage
|
||||
rail within the chassis. The power on this rail may
|
||||
be delivered by AC supplies, DC supplies or battery
|
||||
supplies."
|
||||
::= { chPower 2 }
|
||||
|
||||
chPowerMainVoltage OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The voltage of the chassis's main voltage rail. This rail
|
||||
carries power to all the modules in the chassis. It has
|
||||
an allowable range of 40 volts to 60 volts DC. The value
|
||||
of this object is the actual voltage * 10."
|
||||
::= { chPower 3 }
|
||||
|
||||
chPowerTotalSupply OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The total power being supplied by the chassis's power
|
||||
supplies to the chassis. The value of this object is the
|
||||
actual watts."
|
||||
::= { chPower 4 }
|
||||
|
||||
chPowerTotalLoad OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The total load being presented by the chassis to the
|
||||
chassis's power supplies. The value of
|
||||
this object is the actual watts."
|
||||
::= { chPower 5 }
|
||||
|
||||
chPowerMaxSupply OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The maximum power that could de supplied by the chassis's power
|
||||
supplies to the chassis. The value of this object is the
|
||||
actual watts."
|
||||
::= { chPower 6 }
|
||||
|
||||
chPowerMaxLoad OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The maximum load that could be presented by the chassis to the
|
||||
chassis's power supplies. The value of
|
||||
this object is the actual watts."
|
||||
::= { chPower 7 }
|
||||
|
||||
chPowerTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF ChPowerEntry
|
||||
ACCESS not-accessible
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"A list of power lines or busses on the chassis's backplane."
|
||||
::= { chPower 8 }
|
||||
|
||||
chPowerEntry OBJECT-TYPE
|
||||
SYNTAX ChPowerEntry
|
||||
ACCESS not-accessible
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"A slot entry containing objects for a particular
|
||||
module and associated power line."
|
||||
INDEX { chPowerLineID }
|
||||
::= { chPowerTable 1 }
|
||||
|
||||
ChPowerEntry ::=
|
||||
SEQUENCE {
|
||||
chPowerLineID
|
||||
INTEGER,
|
||||
chPowerLineType
|
||||
OBJECT IDENTIFIER,
|
||||
chPowerLineTotalSupply
|
||||
INTEGER,
|
||||
chPowerLineTotalLoad
|
||||
INTEGER,
|
||||
chPowerLineMaxSupply
|
||||
INTEGER,
|
||||
chPowerLineMaxLoad
|
||||
INTEGER
|
||||
}
|
||||
|
||||
chPowerLineID OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"A unique value used to identify a particular power line on
|
||||
the chassis's backplane."
|
||||
::= { chPowerEntry 1 }
|
||||
|
||||
chPowerLineType OBJECT-TYPE
|
||||
SYNTAX OBJECT IDENTIFIER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The type of power. For example, a power line that supplies
|
||||
DC current at a nominal voltage of 40 to 57 volts or a
|
||||
power line that supplies AC current at a nominal volatge of
|
||||
110v."
|
||||
::= { chPowerEntry 2 }
|
||||
|
||||
chPowerLineTotalSupply OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The total power being supplied by the chassis's power
|
||||
supplies to the chassis on this power line. The value
|
||||
of this object is the actual watts."
|
||||
::= { chPowerEntry 3 }
|
||||
|
||||
chPowerLineTotalLoad OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The total load being presented by the chassis to the
|
||||
chassis's power supplies on this power line. This value
|
||||
will be zero if unknown The value of this object is the
|
||||
actual watts."
|
||||
::= { chPowerEntry 4 }
|
||||
|
||||
chPowerLineMaxSupply OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The maximum power that could de supplied by the chassis's power
|
||||
supplies to the chassison this power line. The value of
|
||||
this object is the actual watts."
|
||||
::= { chPowerEntry 5 }
|
||||
|
||||
chPowerLineMaxLoad OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The maximum load that could be presented by the chassis to the
|
||||
chassis's power supplies on this power line. The value of
|
||||
this object is the actual watts."
|
||||
::= { chPowerEntry 6 }
|
||||
|
||||
chPowerDiagVoltageStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
powerOK(1),
|
||||
overCurrent(2),
|
||||
overVoltage(3),
|
||||
underVoltage(4)
|
||||
}
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This object reflects the state of the diag voltage
|
||||
rail within the chassis."
|
||||
::= { chPower 9 }
|
||||
|
||||
chPowerDiagVoltage OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The voltage of the chassis's diag voltage rail. This rail
|
||||
carries power to all the modules in the chassis. It has
|
||||
an allowable range of 4.75 volts to 5.25 volts DC. The value
|
||||
of this object is the actual voltage * 10."
|
||||
::= { chPower 10 }
|
||||
|
||||
--=============== boardPower group ====================
|
||||
|
||||
-- Board Power Group
|
||||
-- This group covers information on the use of power within the
|
||||
-- chassis by the networking boards.
|
||||
|
||||
boardPowerSlotStatusTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF BoardPowerSlotStatusEntry
|
||||
ACCESS not-accessible
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"A list of networking modules installed in this chassis."
|
||||
::= { boardPower 1 }
|
||||
|
||||
boardPowerSlotStatusEntry OBJECT-TYPE
|
||||
SYNTAX BoardPowerSlotStatusEntry
|
||||
ACCESS not-accessible
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"A slot entry containing objects for a particular
|
||||
module."
|
||||
INDEX { boardPowerSlotStatusID }
|
||||
::= { boardPowerSlotStatusTable 1 }
|
||||
|
||||
BoardPowerSlotStatusEntry ::=
|
||||
SEQUENCE {
|
||||
boardPowerSlotStatusID
|
||||
INTEGER,
|
||||
boardPowerOperationalStatus
|
||||
INTEGER,
|
||||
boardPowerAdminStatus
|
||||
INTEGER,
|
||||
boardPowerLocalAdminStatus
|
||||
INTEGER,
|
||||
boardPowerLocalStatus
|
||||
INTEGER,
|
||||
boardPowerShutdownAdmin
|
||||
INTEGER,
|
||||
boardPowerPriority
|
||||
INTEGER,
|
||||
boardPowerMaxInputPower
|
||||
INTEGER,
|
||||
boardPowerManagement
|
||||
INTEGER
|
||||
}
|
||||
|
||||
boardPowerSlotStatusID OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The slot number of a chassis slot in which this board is
|
||||
installed. This object is similiar to chSlotID in the
|
||||
Chassis MIB."
|
||||
::= { boardPowerSlotStatusEntry 1 }
|
||||
|
||||
boardPowerOperationalStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
powerOn(1),
|
||||
powerOff(2),
|
||||
reset(3),
|
||||
overVoltage(4),
|
||||
underVoltage(5),
|
||||
overCurrent(6),
|
||||
overCurrentShutdown(7),
|
||||
temperatureShutdown(8),
|
||||
remotePowerOff(9),
|
||||
powerConservationShutdown(10),
|
||||
frontPanelPowerOff(11)
|
||||
}
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This object reflects the status of the module's
|
||||
DC-DC converter power supply."
|
||||
::= { boardPowerSlotStatusEntry 2 }
|
||||
|
||||
boardPowerAdminStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
powerOn(1),
|
||||
powerOff(2),
|
||||
reset(3)
|
||||
}
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This object controls the operation of the module's
|
||||
DC-DC power supply. If the value 3 is written to
|
||||
this object then the value of the object will be
|
||||
set to 1 after the reset is performed."
|
||||
DEFVAL { powerOn }
|
||||
::= { boardPowerSlotStatusEntry 3 }
|
||||
|
||||
boardPowerLocalAdminStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
localMode(1),
|
||||
secureMode(2)
|
||||
}
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This object controls the operation of the module's
|
||||
front panel button. In local mode this button may
|
||||
be used to locally control the operation of the
|
||||
DC-DC converter, i.e. power on, power off and
|
||||
reset. In secure mode a request the state of the
|
||||
front panel button is reflected in the object
|
||||
boardPowerOperationalStatus. In secure mode
|
||||
the front panel button has no effect locally."
|
||||
DEFVAL { localMode }
|
||||
::= { boardPowerSlotStatusEntry 4 }
|
||||
|
||||
boardPowerLocalStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
resetRequest(1),
|
||||
powerDownRequest(2),
|
||||
powerOnRequest(3),
|
||||
normal(4)
|
||||
}
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This object reflects the state of the module's front
|
||||
panel button."
|
||||
::= { boardPowerSlotStatusEntry 5 }
|
||||
|
||||
boardPowerShutdownAdmin OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
enabled(1),
|
||||
disabled(2)
|
||||
}
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This object controls whether or not the module should
|
||||
auto power down due to an fault condition."
|
||||
DEFVAL { disabled }
|
||||
::= { boardPowerSlotStatusEntry 6 }
|
||||
|
||||
boardPowerPriority OBJECT-TYPE
|
||||
SYNTAX INTEGER (1..14)
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The module's power-up and power down priority. This is a
|
||||
value of 1 to 14 and is used to decide which modules are
|
||||
allowed to power on in the event that power demand of the
|
||||
chassis is greater than the total power supply. The default
|
||||
value is 14, highest priority. When two modules have equal
|
||||
priority then the module in the lowest slot wins."
|
||||
DEFVAL { 14 }
|
||||
::= { boardPowerSlotStatusEntry 7 }
|
||||
|
||||
boardPowerMaxInputPower OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The maximum input power that this module is allowed
|
||||
to consume. The value of this object is actual
|
||||
watts."
|
||||
::= { boardPowerSlotStatusEntry 8 }
|
||||
|
||||
boardPowerManagement OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
disabled(1),
|
||||
enabled(2),
|
||||
not-supported(7)
|
||||
}
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"Module power management status."
|
||||
DEFVAL { not-supported }
|
||||
::= { boardPowerSlotStatusEntry 9 }
|
||||
|
||||
boardPowerSlotTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF BoardPowerSlotEntry
|
||||
ACCESS not-accessible
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"A list of networking modules and associated power lines
|
||||
installed in this chassis."
|
||||
::= { boardPower 2 }
|
||||
|
||||
boardPowerSlotEntry OBJECT-TYPE
|
||||
SYNTAX BoardPowerSlotEntry
|
||||
ACCESS not-accessible
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"A slot entry containing objects for a particular
|
||||
module and associated power line."
|
||||
INDEX { boardPowerSlotID, boardPowerID }
|
||||
::= { boardPowerSlotTable 1 }
|
||||
|
||||
BoardPowerSlotEntry ::=
|
||||
SEQUENCE {
|
||||
boardPowerSlotID
|
||||
INTEGER,
|
||||
boardPowerID
|
||||
INTEGER,
|
||||
boardPowerType
|
||||
OBJECT IDENTIFIER,
|
||||
boardPowerStatus
|
||||
INTEGER,
|
||||
boardPowerVoltage
|
||||
INTEGER,
|
||||
boardPowerCurrent
|
||||
INTEGER,
|
||||
boardPowerMaxVoltage
|
||||
INTEGER,
|
||||
boardPowerMinVoltage
|
||||
INTEGER,
|
||||
boardPowerMaxPower
|
||||
INTEGER
|
||||
}
|
||||
|
||||
boardPowerSlotID OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The slot number of a chassis slot in which this board is
|
||||
installed. This object is similiar to chSlotID in the
|
||||
Chassis MIB."
|
||||
::= { boardPowerSlotEntry 1 }
|
||||
|
||||
boardPowerID OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"A unique value used to identify a particular power line."
|
||||
::= { boardPowerSlotEntry 2 }
|
||||
|
||||
boardPowerType OBJECT-TYPE
|
||||
SYNTAX OBJECT IDENTIFIER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The type of power. For example, a power line that supplies
|
||||
DC current at a nominal voltage of 40 to 57 volts or a
|
||||
power line that supplies AC current at a nominal volatge of
|
||||
110v."
|
||||
::= { boardPowerSlotEntry 3 }
|
||||
|
||||
boardPowerStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
powerOK(1),
|
||||
powerOff(2),
|
||||
overCurrent(3),
|
||||
overVoltage(4),
|
||||
underVoltage(5)
|
||||
}
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This object reflects the status of this power line."
|
||||
::= { boardPowerSlotEntry 4 }
|
||||
|
||||
boardPowerVoltage OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The voltage reading for the power line. The value of this
|
||||
object is actual voltage * 100."
|
||||
::= { boardPowerSlotEntry 5 }
|
||||
|
||||
boardPowerCurrent OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The current reading for the power line. The value of this
|
||||
object is the actual amperage * 100. If this reading is not
|
||||
implemented then value will be zero."
|
||||
::= { boardPowerSlotEntry 6 }
|
||||
|
||||
boardPowerMaxVoltage OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The maximum voltage for this power line. If the voltage
|
||||
reading for this power line is greater than this value
|
||||
then the power line is considered to be in an overvolatge
|
||||
condition. The value of this object is in voltage * 100."
|
||||
::= { boardPowerSlotEntry 7 }
|
||||
|
||||
boardPowerMinVoltage OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The minimum voltage for this power line. If the voltage
|
||||
reading for this power line is less than this value
|
||||
then the power line is considered to be in an undervolatge
|
||||
condition. The value of this object is voltage * 100."
|
||||
::= { boardPowerSlotEntry 8 }
|
||||
|
||||
boardPowerMaxPower OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The maximum power for this power line. If the power calculated
|
||||
for this power line is greater than this value then the
|
||||
power line is considered to be in an overload condition.
|
||||
The value of this object is in watts."
|
||||
::= { boardPowerSlotEntry 9 }
|
||||
|
||||
--=============== psPower group ====================
|
||||
|
||||
-- AC and DC Power Supply Power Group
|
||||
-- This group covers information on the use of power within the
|
||||
-- chassis by the networking boards.
|
||||
|
||||
psPowerSlotStatusTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF PsPowerSlotStatusEntry
|
||||
ACCESS not-accessible
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"A list of AC & DC power supplies installed in this chassis."
|
||||
::= { psPower 1 }
|
||||
|
||||
psPowerSlotStatusEntry OBJECT-TYPE
|
||||
SYNTAX PsPowerSlotStatusEntry
|
||||
ACCESS not-accessible
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"A slot entry containing objects for a particular
|
||||
power supply."
|
||||
INDEX { psPowerSlotStatusID }
|
||||
::= { psPowerSlotStatusTable 1 }
|
||||
|
||||
PsPowerSlotStatusEntry ::=
|
||||
SEQUENCE {
|
||||
psPowerSlotStatusID
|
||||
INTEGER,
|
||||
psPowerOperationalStatus
|
||||
INTEGER,
|
||||
psPowerAdminStatus
|
||||
INTEGER,
|
||||
psPowerMaxOutputPower
|
||||
INTEGER
|
||||
}
|
||||
|
||||
psPowerSlotStatusID OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The slot number of a chassis slot in which this AC power
|
||||
supply is installed. This object is similiar
|
||||
to chSlotID in the Chassis MIB."
|
||||
::= { psPowerSlotStatusEntry 1 }
|
||||
|
||||
psPowerOperationalStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
powerOn(1),
|
||||
powerOff(2),
|
||||
reset(3),
|
||||
overVoltage(4),
|
||||
underVoltage(5),
|
||||
overCurrent(6),
|
||||
overCurrentShutdown(7),
|
||||
temperatureShutdown(8),
|
||||
remotePowerOff(9)
|
||||
}
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This object reflects the status of the module's
|
||||
DC-DC converter power supply."
|
||||
::= { psPowerSlotStatusEntry 2 }
|
||||
|
||||
psPowerAdminStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
powerOn(1),
|
||||
powerOff(2)
|
||||
}
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This object controls the operation of power supply."
|
||||
DEFVAL { powerOn }
|
||||
::= { psPowerSlotStatusEntry 3 }
|
||||
|
||||
psPowerMaxOutputPower OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The maximum power that this power supply is allowed
|
||||
to ouput. The value of this object is watts."
|
||||
::= { psPowerSlotStatusEntry 4 }
|
||||
|
||||
psPowerSlotTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF PsPowerSlotEntry
|
||||
ACCESS not-accessible
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"A list of power supplies and associated power lines
|
||||
installed in this chassis."
|
||||
::= { psPower 2 }
|
||||
|
||||
psPowerSlotEntry OBJECT-TYPE
|
||||
SYNTAX PsPowerSlotEntry
|
||||
ACCESS not-accessible
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"A slot entry containing objects for a particular
|
||||
power line on a particular power supply."
|
||||
INDEX { psPowerSlotID, psPowerID }
|
||||
::= { psPowerSlotTable 1 }
|
||||
|
||||
PsPowerSlotEntry ::=
|
||||
SEQUENCE {
|
||||
psPowerSlotID
|
||||
INTEGER,
|
||||
psPowerID
|
||||
INTEGER,
|
||||
psPowerType
|
||||
OBJECT IDENTIFIER,
|
||||
psPowerStatus
|
||||
INTEGER,
|
||||
psPowerAdmin
|
||||
INTEGER,
|
||||
psPowerVoltage
|
||||
INTEGER,
|
||||
psPowerCurrent
|
||||
INTEGER,
|
||||
psPowerLineFrequency
|
||||
INTEGER,
|
||||
psPowerMaxVoltage
|
||||
INTEGER,
|
||||
psPowerMinVoltage
|
||||
INTEGER,
|
||||
psPowerMaxPower
|
||||
INTEGER
|
||||
}
|
||||
|
||||
psPowerSlotID OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The slot number of a chassis slot in which this Power
|
||||
supply is installed. This object is similiar to
|
||||
chSlotID in the Chassis MIB."
|
||||
::= { psPowerSlotEntry 1 }
|
||||
|
||||
psPowerID OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"A unique value used to identify a particular power line."
|
||||
::= { psPowerSlotEntry 2 }
|
||||
|
||||
psPowerType OBJECT-TYPE
|
||||
SYNTAX OBJECT IDENTIFIER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The type of power. For example, a power line that supplies
|
||||
DC current at a nominal voltage of 40 to 57 volts or a
|
||||
power line that supplies AC current at a nominal volatge of
|
||||
110v."
|
||||
::= { psPowerSlotEntry 3 }
|
||||
|
||||
psPowerStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
powerOK(1),
|
||||
powerOff(2),
|
||||
overCurrent(3),
|
||||
overVoltage(4),
|
||||
underVoltage(5)
|
||||
}
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This object reflects the status of the power line."
|
||||
::= { psPowerSlotEntry 4 }
|
||||
|
||||
psPowerAdmin OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
powerOn(1),
|
||||
powerOff(2)
|
||||
}
|
||||
ACCESS read-write
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This object controls the operation of power supply."
|
||||
DEFVAL { powerOn }
|
||||
::= { psPowerSlotEntry 5 }
|
||||
|
||||
psPowerVoltage OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The voltage reading for the power line. The value of this
|
||||
object is the actual voltage * 100."
|
||||
::= { psPowerSlotEntry 6 }
|
||||
|
||||
psPowerCurrent OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The current reading for the power line. The value of this
|
||||
object is amperage * 100. If this reading is not implemented
|
||||
then value will be zero."
|
||||
::= { psPowerSlotEntry 7 }
|
||||
|
||||
psPowerLineFrequency OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The line frequency for the power line. The value of this
|
||||
object is the actual frequency in Hertz * 10. If this
|
||||
reading is not implemented then value will be zero."
|
||||
::= { psPowerSlotEntry 8 }
|
||||
|
||||
psPowerMaxVoltage OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The maximum voltage for this power line. If the voltage
|
||||
reading for this power line is greater than this value
|
||||
then the power line is considered to be in an over volatge
|
||||
condition. The value of this object is voltage * 100."
|
||||
::= { psPowerSlotEntry 9 }
|
||||
|
||||
psPowerMinVoltage OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The minimum voltage for this power line. If the voltage
|
||||
reading for this power line is greater than this value
|
||||
then the power line is considered to be in an over volatge
|
||||
condition. The value of this object is voltage * 100."
|
||||
::= { psPowerSlotEntry 10 }
|
||||
|
||||
psPowerMaxPower OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The maximum power for this power line. If the power calculated
|
||||
for this power line is greater than this value then the
|
||||
power line is considered to be in an overload condition.
|
||||
The value of this object is watts."
|
||||
::= { psPowerSlotEntry 11 }
|
||||
|
||||
--=============== bbuPower group ====================
|
||||
|
||||
-- Battery Backup Unit Power Group
|
||||
-- This group covers information on the use of power within the
|
||||
-- chassis by the battery backup unit.
|
||||
|
||||
--=============== termPower group ====================
|
||||
|
||||
-- INB Termination Module Power Group
|
||||
-- This group covers information on the use of power within the
|
||||
-- chassis by the INB termination modules.
|
||||
|
||||
termPowerStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
powerOK(1),
|
||||
overCurrent(2),
|
||||
overVoltage(3),
|
||||
underVolatge(4),
|
||||
overPower(5)
|
||||
}
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This object reflects the status of the chassis's termination
|
||||
voltage rail."
|
||||
::= { termPower 1 }
|
||||
|
||||
termPowerVoltage OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The voltage of the chassis's termination voltage rail.
|
||||
This rail carries power to INB terminator cards in the
|
||||
chassis. It has an allowalble range of 3.3 Volt + or -
|
||||
5%.The value of this object is voltage * 100."
|
||||
::= { termPower 2 }
|
||||
|
||||
termPowerCurrent OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"The current on the chassis's termination voltage rail.
|
||||
The value of this object is the actual amperage * 100.
|
||||
If this reading is not implemented then the value will
|
||||
be zero."
|
||||
::= { termPower 3 }
|
||||
|
||||
termPowerModule1Status OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
normal(1),
|
||||
iNBaFault(2),
|
||||
iNBbFault(3),
|
||||
fault(4),
|
||||
termModuleNotInstalled(5),
|
||||
unknown(6)
|
||||
}
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This object reflects the state of the INB termination
|
||||
module number 1. A value of normal(1) reflects that
|
||||
both busses are normal. A value of fault(4) reflects
|
||||
that both busses are in a fault condition."
|
||||
::= { termPower 4 }
|
||||
|
||||
termPowerModule2Status OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
normal(1),
|
||||
iNBaFault(2),
|
||||
iNBbFault(3),
|
||||
fault(4),
|
||||
termModuleNotInstalled(5),
|
||||
unknown(6)
|
||||
}
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
DESCRIPTION
|
||||
"This object reflects the state of the INB termination
|
||||
module number 2. A value of normal(1) reflects that
|
||||
both busses are normal. A value of fault(4) reflects
|
||||
that both busses are in a fault condition."
|
||||
::= { termPower 5 }
|
||||
|
||||
END
|
Reference in New Issue