CTRON-SMARTTRUNK-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
-- ctron-smarttrunk-mib.txt
|
||||
-- Revision: 01.00.01
|
||||
-- Part Number:
|
||||
-- Date: April 14, 1999
|
||||
|
||||
-- Cabletron Systems, Inc.
|
||||
-- 35 Industrial Way, P.O. Box 5005
|
||||
-- Rochester, NH 03867-0505
|
||||
-- (603) 332-9400
|
||||
-- support@ctron.com
|
||||
|
||||
-- This module provides authoritative definitions for Cabletron's
|
||||
-- enterprise-specific port-trunking MIB.
|
||||
|
||||
--
|
||||
-- This module will be extended, as needed.
|
||||
|
||||
-- Cabletron Systems reserves the right to make changes in
|
||||
-- specification and other information contained in this document
|
||||
-- without prior notice. The reader should consult Cabletron Systems
|
||||
-- to determine whether any such changes have been made.
|
||||
--
|
||||
-- In no event shall Cabletron Systems be liable for any incidental,
|
||||
-- indirect, special, or consequential damages whatsoever (including
|
||||
-- but not limited to lost profits) arising out of or related to this
|
||||
-- document or the information contained in it, even if Cabletron
|
||||
-- Systems has been advised of, known, or should have known, the
|
||||
-- possibility of such damages.
|
||||
--
|
||||
-- Cabletron grants vendors, end-users, and other interested parties
|
||||
-- a non-exclusive license to use this Specification in connection
|
||||
-- with the management of Cabletron products.
|
||||
|
||||
-- Copyright February 1999 Cabletron Systems
|
||||
|
||||
-- Note: the design of this MIB owes much to designers of the LEC MIB.
|
||||
-- Rev: 1.00.01 cleaned up some spaces to allow import into Spectrum MIB Tools.
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter32
|
||||
FROM SNMPv2-SMI
|
||||
TEXTUAL-CONVENTION, RowStatus, DisplayString, TruthValue
|
||||
FROM SNMPv2-TC
|
||||
MODULE-COMPLIANCE, OBJECT-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
InterfaceIndex, ifIndex
|
||||
FROM IF-MIB
|
||||
ctSmartTrunkBranch
|
||||
FROM CTRON-MIB-NAMES;
|
||||
|
||||
ctSmartTrunk MODULE-IDENTITY
|
||||
LAST-UPDATED "199812160000Z"
|
||||
ORGANIZATION "Cabletron Systems, Inc"
|
||||
CONTACT-INFO
|
||||
"Cabletron Systems, Inc.
|
||||
35 Industrial Way, P.O. Box 5005
|
||||
Rochester, NH 03867-0505
|
||||
(603) 332-9400
|
||||
support@cabletron.com
|
||||
http://www.ctron.com"
|
||||
DESCRIPTION
|
||||
"This mib module defines a portion of the SNMP enterprise MIBs under Cabletron
|
||||
enterprise OID pertaining to configuration of Smart TRUNK network links."
|
||||
::= { ctSmartTrunkBranch 1 }
|
||||
|
||||
ctSmartTrunkConfig OBJECT IDENTIFIER ::= { ctSmartTrunk 1 }
|
||||
ctSmartTrunkDebug OBJECT IDENTIFIER ::= { ctSmartTrunk 2 }
|
||||
|
||||
-- Textual Conventions
|
||||
|
||||
CTSmartTrunkProtocol ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Type of trunking protocol used. LLAP based switches should use decHuntGroup.
|
||||
noProcol applies to all other types of connections."
|
||||
SYNTAX INTEGER {
|
||||
noProtocol(1),
|
||||
decHuntGroup(2)
|
||||
}
|
||||
|
||||
CTSmartTrunkIndex ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Most of the tables in this MIB are indexed in whole
|
||||
or in part by 'ctTrunkIndex' - not by 'ifIndex'.
|
||||
Why is there a separate index?
|
||||
Traditionally, ifIndex values are chosen by agents,
|
||||
and are permitted to change across restarts. Using
|
||||
ifIndex to index ctTrunkConfigTable could complicate
|
||||
row creation and/or cause interoperability problems
|
||||
(if each agent had special restrictions on ifIndex).
|
||||
Having a separate index avoids these problems."
|
||||
SYNTAX INTEGER ( 1..2147483647 )
|
||||
|
||||
CTSmartTrunkName ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A textual description of this virtual port."
|
||||
SYNTAX DisplayString (SIZE(0..32))
|
||||
|
||||
CTSmartTrunkLoadBalanceType ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The algorithm in use to assign flows to each link in a Smart TRUNK."
|
||||
SYNTAX INTEGER {
|
||||
balancingUnspecified(1),
|
||||
roundRobin(2),
|
||||
linkUtilization(3)
|
||||
}
|
||||
|
||||
--
|
||||
-- Smart Trunk Configuration
|
||||
--
|
||||
|
||||
ctTrunkGlobalStatus OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The state of Smart TRUNK capability for this entire managed entity. Default Value is True(1). If set to False(2)
|
||||
all smart trunks are put into ifAdminStatus down."
|
||||
::= { ctSmartTrunkConfig 1 }
|
||||
|
||||
ctTrunkConfigTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF CtTrunkConfigEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A table describing all of the trunk interfaces
|
||||
implemented by this host. Each trunk has a row
|
||||
in the MIB-II/RFC 2233 Interfaces table (describing
|
||||
the structure of the trunk interface it presents to higher
|
||||
layers). Each trunk interface also has a row in this and
|
||||
other CTRON-SMARTTRUNK-MIB tables. Smart Trunks use
|
||||
ifType propMultiplexor(54). Counters represent the aggregate of
|
||||
all physcal links.
|
||||
|
||||
Unlike hardware ports, trunk interfaces can be created by
|
||||
management. However, the RFC 2233 Interfaces table
|
||||
does not directly support row creation. Therefore,
|
||||
creating or deleting a row in the ctTrunkConfigTable is
|
||||
defined to have the side effect of creating or
|
||||
deleting corresponding rows in
|
||||
|
||||
- the MIB-II / RFC 2233 Interfaces table,
|
||||
- any other dependent tables
|
||||
|
||||
New Interfaces table rows for trunk intefaces
|
||||
always have 'ifAdminStatus' set to 'down' until the row
|
||||
state is becomes Active. Then administration of the
|
||||
interface uses normal ifTable ifAdminStatus to enabled it."
|
||||
|
||||
::= { ctSmartTrunkConfig 3 }
|
||||
|
||||
ctTrunkConfigEntry OBJECT-TYPE
|
||||
SYNTAX CtTrunkConfigEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Each table entry contains configuration information for one trunk interface."
|
||||
INDEX { ctTrunkIndex }
|
||||
::= { ctTrunkConfigTable 1 }
|
||||
|
||||
CtTrunkConfigEntry ::=
|
||||
SEQUENCE {
|
||||
ctTrunkIndex CTSmartTrunkIndex,
|
||||
ctTrunkConfigName CTSmartTrunkName,
|
||||
ctTrunkConfigProtocol CTSmartTrunkProtocol,
|
||||
ctTrunkConfigLoadBalance CTSmartTrunkLoadBalanceType,
|
||||
ctTrunkIfIndex InterfaceIndex,
|
||||
ctTrunkRowStatus RowStatus
|
||||
}
|
||||
|
||||
ctTrunkIndex OBJECT-TYPE
|
||||
SYNTAX CTSmartTrunkIndex
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A value which uniquely identifies this conceptual
|
||||
row in the ctTrunkConfigTable. The Table allows sparse values.
|
||||
|
||||
If the conceptual row identified by this value of
|
||||
ctTrunkIndex is recreated following an agent restart,
|
||||
the same value of ctTrunkIndex must be used to identify
|
||||
the recreated row. (However, the Interfaces table
|
||||
index associated with the client may change. ifAlias in ifXTable is used
|
||||
then to reassociate ifIndexes based on ifAlias. In the case of the SSR,
|
||||
Smart Trunks are manipulated as st.ctTrunkIndex"
|
||||
::= { ctTrunkConfigEntry 1 }
|
||||
|
||||
ctTrunkConfigName OBJECT-TYPE
|
||||
SYNTAX CTSmartTrunkName
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The Trunk's Name, just for informational purposes. It may be changed
|
||||
regardless of the RowStatus value."
|
||||
|
||||
DEFVAL { "" }
|
||||
::= { ctTrunkConfigEntry 2 }
|
||||
|
||||
ctTrunkConfigProtocol OBJECT-TYPE
|
||||
SYNTAX CTSmartTrunkProtocol
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trunking protocol in use. Once the row is active, it can not be changed."
|
||||
DEFVAL { decHuntGroup }
|
||||
::= { ctTrunkConfigEntry 3 }
|
||||
|
||||
ctTrunkConfigLoadBalance OBJECT-TYPE
|
||||
SYNTAX CTSmartTrunkLoadBalanceType
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The type of load balance algorithm applied to this trunk.
|
||||
Once Row is active, the agent may override this value with an implmentation specific
|
||||
default."
|
||||
DEFVAL { balancingUnspecified }
|
||||
::= { ctTrunkConfigEntry 4 }
|
||||
|
||||
ctTrunkIfIndex OBJECT-TYPE
|
||||
SYNTAX InterfaceIndex
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The ifIndex in ifTable, ifXTable that is associated with the trunk that is
|
||||
represented by this row."
|
||||
::= { ctTrunkConfigEntry 5 }
|
||||
|
||||
ctTrunkRowStatus OBJECT-TYPE
|
||||
SYNTAX RowStatus
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object lets network managers create and delete
|
||||
trunk interfaces, on systems that support this
|
||||
optional capability.
|
||||
|
||||
It does not control the activation and deactivation
|
||||
of these interfaces; they are controlled by 'ifAdminStatus'
|
||||
in the ifTable. However, changing row state from active
|
||||
to notInService. will have the side effect of changing
|
||||
their 'ifAdminStatus' values to 'noPresent' or 'down',
|
||||
thus causing any active trunk connections to be terminated.
|
||||
|
||||
When creating a trunk interface, it is up to the
|
||||
management station to determine a suitable 'ctTrunkIndex'.
|
||||
To facilitate interoperability, agents should not put
|
||||
any restrictions on the 'ctTrunkIndex' beyond the obvious
|
||||
ones that it be valid and unused.
|
||||
|
||||
The Managed Objects that must be set in this table
|
||||
for a row to change from nonExistent/notReady to notInService/Active
|
||||
is simply an index. Ports can then be added to the Smart TRUNK
|
||||
via the ifStackTable.
|
||||
|
||||
If you create a trunk interface via this object,
|
||||
it will initially have
|
||||
'ifAdminStatus' = 'down'
|
||||
'ifOperStatus' = 'down' when RowStatus is changed to active."
|
||||
::= { ctTrunkConfigEntry 6 }
|
||||
|
||||
--
|
||||
-- SmartTrunk Connection Table
|
||||
--
|
||||
|
||||
ctTrunkConnectionTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF CtTrunkConnectionEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table describes how local interfaces that are
|
||||
participating in a trunk are connected to remote
|
||||
interfaces.
|
||||
|
||||
With this table, a management entity can determine
|
||||
that (for example) local interfaces 3, 4, and 6 are
|
||||
connected to remote interfaces 10, 17, and 19.
|
||||
|
||||
This table is useful to debug configuration errors
|
||||
with remote devices. If ifAdminStatus/ifOperState is
|
||||
up, and no corresponding row is found in this table,
|
||||
then a management station can assume a the remote
|
||||
end does not have the decHuntGroup protocol active.
|
||||
|
||||
Note: this entire table is read-only. Rows are
|
||||
created and deleted from this table as a side
|
||||
effect of trunks being created and deleted.
|
||||
|
||||
Note: a managment entity could determine (for
|
||||
example) that interface 3 was participating in
|
||||
trunk 3 by using the ifStackTable and ctTrunkIfIndex."
|
||||
::= { ctSmartTrunkConfig 4 }
|
||||
|
||||
ctTrunkConnectionEntry OBJECT-TYPE
|
||||
SYNTAX CtTrunkConnectionEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Each table entry contains configuration information
|
||||
for one interface that is participating in a trunk."
|
||||
INDEX { ifIndex }
|
||||
::= { ctTrunkConnectionTable 1 }
|
||||
|
||||
CtTrunkConnectionEntry ::=
|
||||
SEQUENCE {
|
||||
ctTrunkPortRemoteIfIndex InterfaceIndex
|
||||
}
|
||||
|
||||
ctTrunkPortRemoteIfIndex OBJECT-TYPE
|
||||
SYNTAX InterfaceIndex
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The ifIndex of the interface at the other end of
|
||||
this part of the trunk link. If this value is 0,
|
||||
then for some reason there is no interface on the
|
||||
other side of this link. This might be a temporary
|
||||
condition or it might represent a real problem.
|
||||
|
||||
Note: this table is indexed by ifIndex. So the
|
||||
index is the local ifIndex value and
|
||||
ctTrunkPortRemoteIfIndex is the remote ifIndex."
|
||||
::= { ctTrunkConnectionEntry 1 }
|
||||
|
||||
-- END of ctTrunkConnectionTable
|
||||
|
||||
ctTrunkLLAPRequirement OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
required(1),
|
||||
notRequired(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates whether this managed entity requires the
|
||||
LLAP updates to perform the trunking function.
|
||||
|
||||
Certain families of products require LLAP (decHuntGroup Protocol)
|
||||
order for the Smart TRUNK functionality to work.
|
||||
A value of 1 implies that LLAP is necessary for smart-trunking
|
||||
to work on this platform, a value of 2 indicates that it is
|
||||
not necessary."
|
||||
::= { ctSmartTrunkDebug 1 }
|
||||
|
||||
ctTrunkMaxTrunks OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The maximum number of trunks that can be configured
|
||||
on this managed entity."
|
||||
::= { ctSmartTrunkDebug 2 }
|
||||
|
||||
-- The Trunk-Flow Diagnostic table
|
||||
--
|
||||
-- this table is optional; it will be implemented on those devices
|
||||
-- that use "flows"
|
||||
ctTrunkFlowDiagnosticTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF CtTrunkFlowDiagnosticEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION "Provide a means to programmatically evaluate the load
|
||||
balancing of a smart trunk. Assumes that load balancing is done on a
|
||||
flow by flow basis."
|
||||
::= { ctSmartTrunkDebug 4 }
|
||||
|
||||
ctTrunkFlowDiagnosticEntry OBJECT-TYPE
|
||||
SYNTAX CtTrunkFlowDiagnosticEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION "Each row refers to a specific smart trunk and port within
|
||||
that smart trunk."
|
||||
INDEX { ctTrunkIndex, ifIndex }
|
||||
::= { ctTrunkFlowDiagnosticTable 1 }
|
||||
|
||||
CtTrunkFlowDiagnosticEntry ::=
|
||||
SEQUENCE {
|
||||
ctTrunkFlowDiagnosticInstalledFlows Counter32
|
||||
}
|
||||
|
||||
ctTrunkFlowDiagnosticInstalledFlows OBJECT-TYPE
|
||||
SYNTAX Counter32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "A counter of the flows installed on this port since it was
|
||||
first operational."
|
||||
::= { ctTrunkFlowDiagnosticEntry 1 }
|
||||
|
||||
-- END of ctTrunkFlowDiagnosticTable
|
||||
|
||||
--
|
||||
-- Compliance
|
||||
--
|
||||
|
||||
ctTrunkConformance OBJECT IDENTIFIER ::= { ctSmartTrunk 3 }
|
||||
ctTrunkCompliances OBJECT IDENTIFIER ::= { ctTrunkConformance 1 }
|
||||
ctTrunkGroups OBJECT IDENTIFIER ::= { ctTrunkConformance 2 }
|
||||
|
||||
ctTrunkComplianceV10 MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The compliance statement for the CTRON-SMARTTRUNK-MIB."
|
||||
MODULE -- this module
|
||||
MANDATORY-GROUPS { ctTrunkConfGroupV10 }
|
||||
|
||||
GROUP ctTrunkFlowDiagnosticGroup
|
||||
DESCRIPTION
|
||||
"This group is mandatory for all network devices
|
||||
which utilize 'flows'. in order to pass packets along their
|
||||
way."
|
||||
|
||||
::= { ctTrunkCompliances 1 }
|
||||
|
||||
ctTrunkConfGroupV10 OBJECT-GROUP
|
||||
OBJECTS {
|
||||
ctTrunkGlobalStatus,
|
||||
ctTrunkRowStatus,
|
||||
ctTrunkConfigName,
|
||||
ctTrunkConfigProtocol,
|
||||
ctTrunkConfigLoadBalance,
|
||||
ctTrunkIfIndex,
|
||||
ctTrunkPortRemoteIfIndex,
|
||||
ctTrunkLLAPRequirement,
|
||||
ctTrunkMaxTrunks
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A set of managed objects that make up version 1.0 of the CTRON-SMARTTRUNK-MIB."
|
||||
::= { ctTrunkGroups 1 }
|
||||
|
||||
ctTrunkFlowDiagnosticGroup OBJECT-GROUP
|
||||
OBJECTS { ctTrunkFlowDiagnosticInstalledFlows }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of diagnostic information related to
|
||||
interfaces participating in SmartTrunks; specifically
|
||||
to interfaces on devices that use 'flows'."
|
||||
::= { ctTrunkGroups 2 }
|
||||
|
||||
END
|