CTTRAPLOG-MIB  DEFINITIONS ::= BEGIN
 | 
			
		||||
 | 
			
		||||
--  cttraplog-mib.txt
 | 
			
		||||
--  Revision: 01.00.02
 | 
			
		||||
--  Part Number:
 | 
			
		||||
--  Date: July 17, 1998
 | 
			
		||||
 | 
			
		||||
--  Cabletron Systems, Inc.
 | 
			
		||||
--  35 Industrial Way, P.O. Box 5005
 | 
			
		||||
--  Rochester, NH 03867-0505
 | 
			
		||||
--  (603) 332-9400
 | 
			
		||||
--  support@ctron.com
 | 
			
		||||
 | 
			
		||||
--  This module provides authoritative definitions for Cabletron's
 | 
			
		||||
--  enterprise-specific trap log mib.
 | 
			
		||||
--
 | 
			
		||||
--  This module will be extended, as required.
 | 
			
		||||
--
 | 
			
		||||
 | 
			
		||||
--  Cabletron Systems reserves the right to make changes in
 | 
			
		||||
--  specification and other information contained in this document
 | 
			
		||||
--  without prior notice.  The reader should consult Cabletron Systems
 | 
			
		||||
--  to determine whether any such changes have been made.
 | 
			
		||||
--
 | 
			
		||||
--  In no event shall Cabletron Systems be liable for any incidental,
 | 
			
		||||
--  indirect, special, or consequential damages whatsoever (including
 | 
			
		||||
--  but not limited to lost profits) arising out of or related to this
 | 
			
		||||
--  document or the information contained in it, even if Cabletron
 | 
			
		||||
--  Systems has been advised of, known, or should have known, the
 | 
			
		||||
--  possibility of such damages.
 | 
			
		||||
--
 | 
			
		||||
--  Cabletron grants vendors, end-users, and other interested parties
 | 
			
		||||
--  a non-exclusive license to use this Specification in connection
 | 
			
		||||
--  with the management of Cabletron products.
 | 
			
		||||
 | 
			
		||||
--  Copyright July 1998 Cabletron Systems
 | 
			
		||||
 | 
			
		||||
--  PLEASE NOTE: All groups in this mib are optional
 | 
			
		||||
 | 
			
		||||
        IMPORTS 
 | 
			
		||||
                DisplayString
 | 
			
		||||
                        FROM RFC1213-MIB
 | 
			
		||||
                Counter, TimeTicks
 | 
			
		||||
                        FROM RFC1155-SMI
 | 
			
		||||
                OBJECT-TYPE
 | 
			
		||||
                        FROM RFC-1212 
 | 
			
		||||
                ctTrapLog
 | 
			
		||||
                        FROM CTRON-MIB-NAMES;
 | 
			
		||||
 | 
			
		||||
        totalNumberOfEntries  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  INTEGER
 | 
			
		||||
            ACCESS  read-only
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "Total number of logged entries for this chassis."
 | 
			
		||||
            ::= { ctTrapLog 1 }
 | 
			
		||||
 | 
			
		||||
        configTable  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  SEQUENCE OF ConfigTableEntry
 | 
			
		||||
            ACCESS  not-accessible
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            ::= { ctTrapLog 2 }
 | 
			
		||||
 | 
			
		||||
        configTableEntry  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  ConfigTableEntry
 | 
			
		||||
            ACCESS  not-accessible
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "Each entry allows a user to configure the alarm table
 | 
			
		||||
                    for a specific slot. Objects such as Current Entry,
 | 
			
		||||
                    MaxEntries Allowed, and an Enable/Disable switch are
 | 
			
		||||
                    available."
 | 
			
		||||
            INDEX   { slotInChassis }
 | 
			
		||||
            ::= { configTable 1 }
 | 
			
		||||
 | 
			
		||||
        ConfigTableEntry ::=
 | 
			
		||||
            SEQUENCE { 
 | 
			
		||||
                slotInChassis
 | 
			
		||||
                    INTEGER,
 | 
			
		||||
                numEntriesLoggeds
 | 
			
		||||
                    Counter,
 | 
			
		||||
                numEntriesRequested
 | 
			
		||||
                    INTEGER,
 | 
			
		||||
                numEntriesAllocated
 | 
			
		||||
                    INTEGER,
 | 
			
		||||
                lastLoggedEntryLogId
 | 
			
		||||
                    INTEGER,
 | 
			
		||||
                logCommand
 | 
			
		||||
                    INTEGER,
 | 
			
		||||
                wrap
 | 
			
		||||
                    INTEGER
 | 
			
		||||
            }
 | 
			
		||||
 | 
			
		||||
        slotInChassis  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  INTEGER
 | 
			
		||||
            ACCESS  read-only
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "Each Slot can be separately configured. This is the
 | 
			
		||||
                    slot number for the configuration entry. "
 | 
			
		||||
            ::= { configTableEntry 1 }
 | 
			
		||||
 | 
			
		||||
        numEntriesLoggeds  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  Counter
 | 
			
		||||
            ACCESS  read-only
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "This is the total number of entries looged for this
 | 
			
		||||
                    slot."
 | 
			
		||||
            ::= { configTableEntry 2 }
 | 
			
		||||
 | 
			
		||||
        numEntriesRequested  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  INTEGER
 | 
			
		||||
            ACCESS  read-write
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "Maximum number of entries to store before wrapping
 | 
			
		||||
                    the log on this slot."
 | 
			
		||||
            ::= { configTableEntry 3 }
 | 
			
		||||
 | 
			
		||||
        numEntriesAllocated  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  INTEGER
 | 
			
		||||
            ACCESS  read-only
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "This is the number of entries allocated to log alarms
 | 
			
		||||
                    on this slot. It will always be less than or equal
 | 
			
		||||
                    to the requested number of entries."
 | 
			
		||||
            ::= { configTableEntry 4 }
 | 
			
		||||
 | 
			
		||||
        lastLoggedEntryLogId  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  INTEGER
 | 
			
		||||
            ACCESS  read-only
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "This is the log id of the last entry logged for this
 | 
			
		||||
                    slot."
 | 
			
		||||
            ::= { configTableEntry 5 }
 | 
			
		||||
 | 
			
		||||
        logCommand  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  INTEGER {
 | 
			
		||||
                        clearLog (1)
 | 
			
		||||
                    }
 | 
			
		||||
            ACCESS  read-write
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "Allows the user to send the log the commands
 | 
			
		||||
                    specified in the enumeration."
 | 
			
		||||
            ::= { configTableEntry 6 }
 | 
			
		||||
 | 
			
		||||
        wrap  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  INTEGER 
 | 
			
		||||
            ACCESS  read-only
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "This is whether or not this configuration has
 | 
			
		||||
                    wrapped or not."
 | 
			
		||||
            ::= { configTableEntry 7 }
 | 
			
		||||
 | 
			
		||||
        trapLogTable  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  SEQUENCE OF TrapLogEntry
 | 
			
		||||
            ACCESS  not-accessible
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            ::= { ctTrapLog 3 }
 | 
			
		||||
 | 
			
		||||
        trapLogEntry  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  TrapLogEntry
 | 
			
		||||
            ACCESS  not-accessible
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "Each alarm entry is generated from one of the
 | 
			
		||||
                    following sources; (1) a module in one of the main
 | 
			
		||||
                    chassis slots, (2) the EM, (3) or a power supply. "
 | 
			
		||||
            INDEX   { slotChassis,
 | 
			
		||||
                      logId }
 | 
			
		||||
            ::= { trapLogTable 1 }
 | 
			
		||||
 | 
			
		||||
        TrapLogEntry ::=
 | 
			
		||||
            SEQUENCE { 
 | 
			
		||||
                logId
 | 
			
		||||
                    INTEGER,
 | 
			
		||||
                nvmpId
 | 
			
		||||
                    INTEGER,
 | 
			
		||||
                trapLogAcknowledged
 | 
			
		||||
                    INTEGER,
 | 
			
		||||
                trapLogVarBind
 | 
			
		||||
                    OCTET STRING,
 | 
			
		||||
                trapLogDescription
 | 
			
		||||
                    DisplayString,
 | 
			
		||||
                timeLogged
 | 
			
		||||
                    TimeTicks,
 | 
			
		||||
                filterId
 | 
			
		||||
                    INTEGER,
 | 
			
		||||
               slotChassis
 | 
			
		||||
                    INTEGER,
 | 
			
		||||
               trapOID
 | 
			
		||||
                    OBJECT IDENTIFIER,
 | 
			
		||||
                z80Time
 | 
			
		||||
                    TimeTicks
 | 
			
		||||
            }
 | 
			
		||||
 | 
			
		||||
        logId  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  INTEGER
 | 
			
		||||
            ACCESS  read-only
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "Each slot has a maximium number of log entries that it
 | 
			
		||||
                    can support. Each entry is assigned a monotonically
 | 
			
		||||
                    increasing sequence number. When the maximum number
 | 
			
		||||
                    of entries for a slot is reached, the log wraps. Each
 | 
			
		||||
                    new entry will replace the oldest entry for that slot."
 | 
			
		||||
            ::= { trapLogEntry 1 }
 | 
			
		||||
 | 
			
		||||
        nvmpId  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  INTEGER
 | 
			
		||||
            ACCESS  read-only
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "This contains the nvmp id of the trap that occurred."
 | 
			
		||||
            ::= { trapLogEntry 2 }
 | 
			
		||||
 | 
			
		||||
        trapLogAcknowledged  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  INTEGER
 | 
			
		||||
            ACCESS  read-only
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "This field is set to 2 if a trap as been acknowledged
 | 
			
		||||
                    from the EM."
 | 
			
		||||
            ::= { trapLogEntry 3 }
 | 
			
		||||
 | 
			
		||||
        trapLogVarBind  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  OCTET STRING (SIZE (0..1500))
 | 
			
		||||
            ACCESS  read-only
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "This is an ASN.1 encoded string representing the pairs
 | 
			
		||||
                    of OID/value items supplied in the original SNMP or
 | 
			
		||||
                    NVMP trap. "
 | 
			
		||||
            ::= { trapLogEntry 4 }
 | 
			
		||||
 | 
			
		||||
        trapLogDescription  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  DisplayString (SIZE (0..80))
 | 
			
		||||
            ACCESS  read-only
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "This is an internally defined string used to describe
 | 
			
		||||
                    an alarm. Its primary use is for display on the EMs
 | 
			
		||||
                    LCD. A default value will be used for the old trap
 | 
			
		||||
                    calls."
 | 
			
		||||
            ::= { trapLogEntry 5 }
 | 
			
		||||
 | 
			
		||||
        timeLogged  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  TimeTicks
 | 
			
		||||
            ACCESS  read-only
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "The time the entry was logged. This will be date and
 | 
			
		||||
                    time if possible."
 | 
			
		||||
            ::= { trapLogEntry 6 }
 | 
			
		||||
 | 
			
		||||
        filterId  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  INTEGER {
 | 
			
		||||
                        informational (1),
 | 
			
		||||
                        warning (2),
 | 
			
		||||
                        severe (3),
 | 
			
		||||
                        fatal (4),
 | 
			
		||||
                        existing (5)
 | 
			
		||||
                    }
 | 
			
		||||
            ACCESS  read-only
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "This will be used to filter certain alarms. The
 | 
			
		||||
                    criteria is TBD. An example of classification:
 | 
			
		||||
                    informational - requires no intervention. warning -
 | 
			
		||||
                    Does not require immediate intervention. e.g. static
 | 
			
		||||
                    risk severe - Requires immediate intervention. e.g.
 | 
			
		||||
                    power overload. fatal - Requires attention and
 | 
			
		||||
                    module may take corrective action such as reboot. e.g.
 | 
			
		||||
                    Unrecoverable software or hardware error. "
 | 
			
		||||
            ::= { trapLogEntry 7 }
 | 
			
		||||
 | 
			
		||||
        slotChassis  OBJECT-TYPE
 | 
			
		||||
            SYNTAX  INTEGER
 | 
			
		||||
            ACCESS  read-only
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION
 | 
			
		||||
                    "Slot of this trap log."
 | 
			
		||||
            ::= { trapLogEntry 8 }
 | 
			
		||||
 | 
			
		||||
        trapOID  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  OBJECT IDENTIFIER
 | 
			
		||||
            ACCESS  read-only
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "This OID combines the General Trap code, Specific
 | 
			
		||||
                    Trap code, and the sys object id into one OID."
 | 
			
		||||
            ::= { trapLogEntry 9 }
 | 
			
		||||
 | 
			
		||||
        z80Time  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  TimeTicks
 | 
			
		||||
            ACCESS  read-only
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "This is the time that the Z80 has been up for the 
 | 
			
		||||
                    board that sent this trap."
 | 
			
		||||
            ::= { trapLogEntry 10 }
 | 
			
		||||
 | 
			
		||||
        filterTable  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  SEQUENCE OF FilterEntry
 | 
			
		||||
            ACCESS  not-accessible
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            ::= { ctTrapLog 4 }
 | 
			
		||||
 | 
			
		||||
        filterEntry  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  FilterEntry
 | 
			
		||||
            ACCESS  not-accessible
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "Each filter entry is generated from one of the
 | 
			
		||||
                    following sources; (1) a module in one of the main
 | 
			
		||||
                    chassis slots, (2) the EM, (3) or a power supply. "
 | 
			
		||||
            INDEX   { filterSlotInChassis,
 | 
			
		||||
                      filterFilterId,
 | 
			
		||||
                      filterLogId }
 | 
			
		||||
            ::= { filterTable 1 }
 | 
			
		||||
 | 
			
		||||
        FilterEntry ::=
 | 
			
		||||
            SEQUENCE { 
 | 
			
		||||
                filterLogId
 | 
			
		||||
                    INTEGER,
 | 
			
		||||
                filterNvmpId
 | 
			
		||||
                    INTEGER,
 | 
			
		||||
                filterTrapLogAcknowledged
 | 
			
		||||
                    INTEGER,
 | 
			
		||||
                filterTrapLogVarBind
 | 
			
		||||
                    OCTET STRING,
 | 
			
		||||
                filterTrapLogDescription
 | 
			
		||||
                    DisplayString,
 | 
			
		||||
                filterTimeLogged
 | 
			
		||||
                    TimeTicks,
 | 
			
		||||
                filterFilterId
 | 
			
		||||
                    INTEGER,
 | 
			
		||||
                filterSlotInChassis
 | 
			
		||||
                    INTEGER,
 | 
			
		||||
                filterTrapOID
 | 
			
		||||
                    OBJECT IDENTIFIER,
 | 
			
		||||
                filterZ80Time
 | 
			
		||||
                    TimeTicks
 | 
			
		||||
            }
 | 
			
		||||
 | 
			
		||||
        filterLogId  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  INTEGER
 | 
			
		||||
            ACCESS  read-only
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "Each slot has a maximum number of log entries that it
 | 
			
		||||
                    can support. Each entry is assigned a monotonically
 | 
			
		||||
                    increasing sequence number. When the maximum number of
 | 
			
		||||
                    entries for a slot is reached, the log wraps. Each new
 | 
			
		||||
                    entry willreplace the oldest entry for that slot."
 | 
			
		||||
            ::= { filterEntry 1 }
 | 
			
		||||
 | 
			
		||||
        filterNvmpId  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  INTEGER
 | 
			
		||||
            ACCESS  read-only
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "This contains the nvmp id of the trap that was 
 | 
			
		||||
                    generated."
 | 
			
		||||
            ::= { filterEntry 2 }
 | 
			
		||||
 | 
			
		||||
        filterTrapLogAcknowledged  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  INTEGER
 | 
			
		||||
            ACCESS  read-only
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "This field is non-zero if a trap has been acknowleged
 | 
			
		||||
                    from the EM."
 | 
			
		||||
            ::= { filterEntry 3 }
 | 
			
		||||
 | 
			
		||||
        filterTrapLogVarBind  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  OCTET STRING (SIZE (0..1500))
 | 
			
		||||
            ACCESS  read-only
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "This is an ASN.1 encoded string representing the pairs
 | 
			
		||||
                    of OID/value items supplied in the original SNMP or
 | 
			
		||||
                    NVMP trap."
 | 
			
		||||
            ::= { filterEntry 4 }
 | 
			
		||||
 | 
			
		||||
        filterTrapLogDescription  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  DisplayString (SIZE (0..80))
 | 
			
		||||
            ACCESS  read-only
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "This is an internally defined string used to
 | 
			
		||||
                    describe an alarm. It's primary use is for display
 | 
			
		||||
                    on the EMs LCD. A default value will be used for 
 | 
			
		||||
                    the old trap calls."
 | 
			
		||||
            ::= { filterEntry 5 }
 | 
			
		||||
 | 
			
		||||
        filterTimeLogged  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  TimeTicks
 | 
			
		||||
            ACCESS  read-only
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "The time the entry was logged. This will be date
 | 
			
		||||
                    and time if possible."
 | 
			
		||||
            ::= { filterEntry 6 }
 | 
			
		||||
 | 
			
		||||
        filterFilterId  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  INTEGER {
 | 
			
		||||
                        informational (1),
 | 
			
		||||
                        warning (2),
 | 
			
		||||
                        severe (3),
 | 
			
		||||
                        fatal (4),
 | 
			
		||||
                        existing (5)
 | 
			
		||||
                    }
 | 
			
		||||
            ACCESS  read-only
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "This will be used tofilter certain alarms. The
 | 
			
		||||
                    criteria is TBD. An example of classification:
 | 
			
		||||
                    informational-requires no intervention. warning - 
 | 
			
		||||
                    Does not require immediate intervention. e.g. 
 | 
			
		||||
                    statis risk severe - Requires immediate 
 | 
			
		||||
                    intervention. e.g. power overload. fatal - 
 | 
			
		||||
                    Requires attention and module may take
 | 
			
		||||
                    corrective action such as reboot. e.g. Unrecoverale
 | 
			
		||||
                    software or hardware error."
 | 
			
		||||
            ::= { filterEntry 7 }
 | 
			
		||||
 | 
			
		||||
        filterSlotInChassis  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  INTEGER
 | 
			
		||||
            ACCESS  read-only
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "Slot of this filter entry."
 | 
			
		||||
            ::= { filterEntry 8 }
 | 
			
		||||
 | 
			
		||||
        filterTrapOID  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  OBJECT IDENTIFIER
 | 
			
		||||
            ACCESS  read-only
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "This OID combines the General Trap code, Specific
 | 
			
		||||
                    Trap code, and the sys object id into one OID."
 | 
			
		||||
            ::= { filterEntry 9 }
 | 
			
		||||
 | 
			
		||||
        filterZ80Time  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  TimeTicks
 | 
			
		||||
            ACCESS  read-only
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "The number of time ticks that have passed since
 | 
			
		||||
                    this boards Z80 processor has been up."
 | 
			
		||||
            ::= { filterEntry 10 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
       trapLoggerAgent  OBJECT-TYPE 
 | 
			
		||||
            SYNTAX  INTEGER {
 | 
			
		||||
                disabled(1),
 | 
			
		||||
                enabled(2),
 | 
			
		||||
                standby(3),
 | 
			
		||||
                elected(4)
 | 
			
		||||
                }
 | 
			
		||||
            ACCESS  read-write
 | 
			
		||||
            STATUS  mandatory
 | 
			
		||||
            DESCRIPTION  
 | 
			
		||||
                    "Reflects the operational status of the traplogger agent"
 | 
			
		||||
        ::= { ctTrapLog 5 }
 | 
			
		||||
        
 | 
			
		||||
END
 | 
			
		||||