Initial commit
This commit is contained in:
105
MIBS/ericsson/PT-MIB
Normal file
105
MIBS/ericsson/PT-MIB
Normal file
@ -0,0 +1,105 @@
|
||||
PT-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY,
|
||||
OBJECT-TYPE FROM SNMPv2-SMI
|
||||
MODULE-COMPLIANCE,
|
||||
OBJECT-GROUP FROM SNMPv2-CONF
|
||||
miniLink FROM MINI-LINK-MIB;
|
||||
|
||||
pt MODULE-IDENTITY
|
||||
LAST-UPDATED "201701211200Z"
|
||||
ORGANIZATION "Ericsson"
|
||||
CONTACT-INFO
|
||||
"Anders Ekvall
|
||||
Postal: Ericsson AB,
|
||||
E-Mail: anders.ekvall@ericsson.com"
|
||||
|
||||
DESCRIPTION
|
||||
"This is the MIB of PT specifics.
|
||||
The entPhysical and ifIndex used are based on the MOC below:
|
||||
IP_INTERFACE_MOC 10000
|
||||
LANX_PORT_MOC 20000
|
||||
WANX_PORT_MOC 30000
|
||||
PT_MOC 40000
|
||||
OM_MOC 50000
|
||||
RMM_MOC 60000
|
||||
SFP_MOC 70000
|
||||
WIFI_MOC 80000
|
||||
RJ45_MOC 90000
|
||||
XPIC_MOC 100000
|
||||
CT_MOC 110000
|
||||
RLT_MOC 120000
|
||||
|
||||
As MOI, slot and port are added according to:
|
||||
Slot no * 100
|
||||
Port no * 1
|
||||
|
||||
For example an SFP in slot 1 port 3: 70103"
|
||||
|
||||
REVISION "201701211200Z"
|
||||
DESCRIPTION
|
||||
"MOC and MOI explained."
|
||||
|
||||
REVISION "201603091200Z"
|
||||
DESCRIPTION
|
||||
"Validated."
|
||||
|
||||
REVISION "201602101230Z"
|
||||
DESCRIPTION
|
||||
"The initial version of this MIB module."
|
||||
|
||||
::= { miniLink 2 }
|
||||
|
||||
|
||||
-- ************
|
||||
-- * PT *
|
||||
-- ************
|
||||
|
||||
ptDeviceType OBJECT-TYPE
|
||||
SYNTAX OBJECT IDENTIFIER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object represents type of the PT. Always set to the
|
||||
same value as 'sysObjectID'."
|
||||
::= { pt 1 }
|
||||
|
||||
--ptTrap ::= { pt 2 }
|
||||
--ptFM ::= { pt 3 }
|
||||
--ptMonitor ::= { pt 4 }
|
||||
--ptPM ::= { pt 5 }
|
||||
--ptSFP ::= { pt 6 }
|
||||
--ptRadioLink ::= { pt 7 }
|
||||
|
||||
ptConformance OBJECT IDENTIFIER ::= { pt 8 }
|
||||
|
||||
--
|
||||
-- Conformance
|
||||
--
|
||||
|
||||
ptCompliances OBJECT IDENTIFIER ::= { ptConformance 1 }
|
||||
ptGroups OBJECT IDENTIFIER ::= { ptConformance 2 }
|
||||
|
||||
ptCompliance MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The compliance statement for SNMP entities which implement everything."
|
||||
MODULE -- This Module
|
||||
MANDATORY-GROUPS { ptCompleteGroup }
|
||||
::= { ptCompliances 1 }
|
||||
|
||||
ptCompleteGroup OBJECT-GROUP
|
||||
OBJECTS
|
||||
{
|
||||
ptDeviceType
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of all current objects in this MIB module."
|
||||
::= { ptGroups 1 }
|
||||
|
||||
END
|
||||
|
||||
|
||||
|