@ -0,0 +1,790 @@
|
||||
-- *****************************************************************
|
||||
-- RBN-ENVMON-MIB Environmental Monitor MIB
|
||||
--
|
||||
-- Copyright (c) 1999-2007, 2010-2011 Ericsson AB
|
||||
-- All rights reserved.
|
||||
--
|
||||
-- *****************************************************************
|
||||
|
||||
RBN-ENVMON-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY,
|
||||
OBJECT-TYPE,
|
||||
NOTIFICATION-TYPE,
|
||||
Unsigned32,
|
||||
Integer32
|
||||
FROM SNMPv2-SMI
|
||||
DisplayString,
|
||||
TruthValue,
|
||||
TEXTUAL-CONVENTION
|
||||
FROM SNMPv2-TC
|
||||
MODULE-COMPLIANCE,
|
||||
OBJECT-GROUP,
|
||||
NOTIFICATION-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
entPhysicalIndex
|
||||
FROM ENTITY-MIB
|
||||
rbnMgmt
|
||||
FROM RBN-SMI;
|
||||
|
||||
rbnEnvMonMIB MODULE-IDENTITY
|
||||
LAST-UPDATED "201210030000Z" -- October 3, 2012
|
||||
ORGANIZATION "Ericsson AB."
|
||||
CONTACT-INFO
|
||||
" Ericsson AB.
|
||||
|
||||
Postal: 100 Headquarters Dr.
|
||||
San Jose, CA 95134
|
||||
USA
|
||||
|
||||
Phone: +1 408 750 5000
|
||||
Fax: +1 408 750 5599
|
||||
|
||||
"
|
||||
DESCRIPTION
|
||||
"The MIB used to genericially manage Environmental
|
||||
Monitor functionality on network devices."
|
||||
|
||||
REVISION "201210030000Z" -- October 3, 2012
|
||||
DESCRIPTION
|
||||
"Removed DISPLAY-HINT from RbnVoltage and RbnFanSpeed."
|
||||
|
||||
REVISION "201101191800Z" -- Jan 19, 2011
|
||||
DESCRIPTION
|
||||
"Update CONTACT-INFO & ORGANIZATION. "
|
||||
|
||||
REVISION "201011110000Z" -- Nov 11, 2010
|
||||
DESCRIPTION
|
||||
"Add new Table rbnEntityTempSensorTable. This will display
|
||||
the TempSensor Details for all the entities. "
|
||||
|
||||
REVISION "200601160000Z" -- January 16, 2006
|
||||
DESCRIPTION
|
||||
"Add textual convention RbnFanSpeed. Add new OIDs:
|
||||
rbnFanUnitID
|
||||
rbnFanUnitDescr
|
||||
rbnFanSpeedCurrent
|
||||
rbnEnvMonFanSpeedObjectGroup
|
||||
rbnEnvMonMIBComplianceV4
|
||||
"
|
||||
REVISION "200206050000Z" -- June 5, 2002
|
||||
DESCRIPTION
|
||||
"Update/correct CONTACT-INFO. Fix syntax errors on IMPORTS list,
|
||||
ranges on Integer32, and size for DisplayString types.
|
||||
Restore the incorrectly deprecated OIDs to current, since they
|
||||
are still supported."
|
||||
REVISION "200107250000Z" -- July 25, 2001
|
||||
DESCRIPTION
|
||||
"Added new OIDs:
|
||||
rbnFanStatus
|
||||
rbnPowerStatus
|
||||
rbnFanStatusChange
|
||||
rbnPowerStatusChange
|
||||
rbnEnvMonMIBObjectGroupV2
|
||||
rbnEnvMonMIBNotificationGroupV2
|
||||
rbnEnvMonMIBComplianceV3
|
||||
Deprecated the OIDs:
|
||||
rbnFanFail
|
||||
rbnPowerFail
|
||||
rbnFanFailChange
|
||||
rbnPowerFailChange
|
||||
rbnEnvMonMIBObjectGroup
|
||||
rbnEnvMonMIBNotificationGroup
|
||||
rbnEnvMonMIBComplianceV2
|
||||
"
|
||||
REVISION "200004240000Z" -- May 24, 2000
|
||||
DESCRIPTION
|
||||
"Added voltage and temperature sensor tables."
|
||||
|
||||
REVISION "199903100000Z" -- Mar 10, 1999
|
||||
DESCRIPTION
|
||||
"Initial version."
|
||||
::= { rbnMgmt 4 }
|
||||
|
||||
rbnEnvMonMIBNotifications OBJECT IDENTIFIER
|
||||
::= { rbnEnvMonMIB 0 }
|
||||
|
||||
rbnEnvMonMIBObjects OBJECT IDENTIFIER
|
||||
::= { rbnEnvMonMIB 1 }
|
||||
|
||||
rbnEnvMonMIBConformance OBJECT IDENTIFIER
|
||||
::= { rbnEnvMonMIB 2 }
|
||||
|
||||
|
||||
-- Textual Conventions
|
||||
|
||||
RbnVoltage ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Represents a voltage value. The value is millivolts.
|
||||
For example, a voltage of 5.5V would be represented
|
||||
by the value 5500."
|
||||
SYNTAX Unsigned32 (0..50000)
|
||||
|
||||
RbnTemperature ::= TEXTUAL-CONVENTION
|
||||
DISPLAY-HINT "d"
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Represents a temperature, in degrees Celsius. In the
|
||||
unlikely event that the temperature to be reported is
|
||||
less than 0 degrees Celsius, a value of 0 will be
|
||||
used. Likewise, if the temperature is greater than
|
||||
100, a value of 100 will be used."
|
||||
SYNTAX Unsigned32 (0..100)
|
||||
|
||||
RbnFanSpeed ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Represents a fan speed value in units of Revolutions Per
|
||||
Minute(RPM)."
|
||||
SYNTAX Unsigned32
|
||||
|
||||
-- MIB Objects
|
||||
|
||||
rbnFanStatusTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RbnFanStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains one row per fan test point.
|
||||
Note that there is not necessarily a one-to-one
|
||||
relationship between fan test points and fan
|
||||
assemblies; a single test point may be used to
|
||||
monitor the status of multiple fans."
|
||||
::= { rbnEnvMonMIBObjects 1 }
|
||||
|
||||
rbnFanStatusEntry OBJECT-TYPE
|
||||
SYNTAX RbnFanStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Information about a particular fan test point"
|
||||
INDEX { rbnFanIndex }
|
||||
::= { rbnFanStatusTable 1 }
|
||||
|
||||
RbnFanStatusEntry ::= SEQUENCE {
|
||||
rbnFanIndex Integer32,
|
||||
rbnFanDescr DisplayString,
|
||||
rbnFanFail TruthValue,
|
||||
rbnFanStatus INTEGER
|
||||
}
|
||||
|
||||
rbnFanIndex OBJECT-TYPE
|
||||
SYNTAX Integer32(1..2147483647)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The index of a fan test point."
|
||||
::= { rbnFanStatusEntry 1 }
|
||||
|
||||
rbnFanDescr OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..32))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The description of a fan test point. If an instance of
|
||||
this object is associated with a single fan assembly,
|
||||
then the value of this object should be the same as the
|
||||
name by which the assembly is normally referenced. If
|
||||
an instance is associated with multiple fan assemblies,
|
||||
then the value of this object should contain the names
|
||||
of all of the fan assemblies being monitored."
|
||||
::= { rbnFanStatusEntry 2 }
|
||||
|
||||
rbnFanFail OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"The status of a fan test point. If an instance of
|
||||
this object has the value true, then a fan monitored
|
||||
by the test point has failed. If an instance of
|
||||
this object has the value false, then the fan (or fans)
|
||||
monitored by the test point are operational."
|
||||
::= { rbnFanStatusEntry 3 }
|
||||
|
||||
rbnFanStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
normal(1),
|
||||
failed(2),
|
||||
absent(3),
|
||||
unknown(4)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The status of a fan test point. If an instance of
|
||||
this object has the value normal, then the fan (or
|
||||
fans) monitored by the test point is operational. If
|
||||
an instance of this object has the value failed, then
|
||||
the fan (or fans) monitored by the test point has
|
||||
failed. If an instance of this object has the value
|
||||
absent, then the fan (or fans) monitored by this test
|
||||
point is not present. If an instance of this object has
|
||||
the value unknown, then the test point is unable to
|
||||
monitor the fan (or fans)."
|
||||
::= { rbnFanStatusEntry 4 }
|
||||
|
||||
rbnPowerStatusTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RbnPowerStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains one row per power test point.
|
||||
Note that there is not necessarily a one-to-one
|
||||
relationship between power test points and power
|
||||
supply assemblies; a single test point may be used
|
||||
to monitor the status of multiple power supplies."
|
||||
::= { rbnEnvMonMIBObjects 2 }
|
||||
|
||||
rbnPowerStatusEntry OBJECT-TYPE
|
||||
SYNTAX RbnPowerStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Information about a particular power test point"
|
||||
INDEX { rbnPowerIndex }
|
||||
::= { rbnPowerStatusTable 1 }
|
||||
|
||||
RbnPowerStatusEntry ::= SEQUENCE {
|
||||
rbnPowerIndex Integer32,
|
||||
rbnPowerDescr DisplayString,
|
||||
rbnPowerFail TruthValue,
|
||||
rbnPowerStatus INTEGER
|
||||
}
|
||||
|
||||
rbnPowerIndex OBJECT-TYPE
|
||||
SYNTAX Integer32(1..2147483647)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The index of a power test point."
|
||||
::= { rbnPowerStatusEntry 1 }
|
||||
|
||||
rbnPowerDescr OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..32))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The description of a power supply test point. If an
|
||||
instance of this object is associated with a single
|
||||
power supply assembly, then the value of this object
|
||||
should be the same as the name by which the assembly
|
||||
is normally referenced. If an instance is associated
|
||||
with multiple power supply assemblies, then the value
|
||||
of this object should contain the names of all of the
|
||||
power supply assemblies being monitored."
|
||||
::= { rbnPowerStatusEntry 2 }
|
||||
|
||||
rbnPowerFail OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"The status of a power test point. If an instance of
|
||||
this object has the value true, then a power supply
|
||||
monitored by the test point has failed. If an instance
|
||||
of this object has the value false, then the power
|
||||
supply (or supplies) monitored by the test point are
|
||||
operational."
|
||||
::= { rbnPowerStatusEntry 3 }
|
||||
|
||||
rbnPowerStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
normal(1),
|
||||
failed(2),
|
||||
absent(3),
|
||||
unknown(4)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The status of a power test point. If an instance of
|
||||
this object has the value normal, then the power
|
||||
supply (or supplies) monitored by the test point is
|
||||
operational. If an instance of this object has the
|
||||
value failed, then the power supply (or supplies)
|
||||
monitored by the test point has failed. If an instance
|
||||
of this object has the value absent, then the power
|
||||
supply (or supplies) monitored by this test point is
|
||||
not present. If an instance of this object has
|
||||
the value unknown, then the test point is unable to
|
||||
monitor the power supply (or supplies)."
|
||||
::= { rbnPowerStatusEntry 4 }
|
||||
|
||||
rbnVoltageSensorTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RbnVoltageSensorEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains one row per voltage test point.
|
||||
Each physical entity (e.g. cards) in the system may
|
||||
contain zero or more voltage test points."
|
||||
::= { rbnEnvMonMIBObjects 3 }
|
||||
|
||||
rbnVoltageSensorEntry OBJECT-TYPE
|
||||
SYNTAX RbnVoltageSensorEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Information about a particular voltage test point."
|
||||
INDEX { entPhysicalIndex, rbnVoltageIndex }
|
||||
::= { rbnVoltageSensorTable 1 }
|
||||
|
||||
RbnVoltageSensorEntry ::= SEQUENCE {
|
||||
rbnVoltageIndex Integer32,
|
||||
rbnVoltageDescr DisplayString,
|
||||
rbnVoltageDesired RbnVoltage,
|
||||
rbnVoltageCurrent RbnVoltage
|
||||
}
|
||||
|
||||
rbnVoltageIndex OBJECT-TYPE
|
||||
SYNTAX Integer32(1..2147483647)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An arbitrary value which uniquely identifies a
|
||||
voltage test point on a particular physical entity.
|
||||
Index values for different test points are not
|
||||
necessarily contiguous."
|
||||
::= { rbnVoltageSensorEntry 1 }
|
||||
|
||||
rbnVoltageDescr OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..48))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The description of a voltage test point. Typically
|
||||
an instance of this object will hold a user-friendly
|
||||
description of the physical entity and the level of
|
||||
voltage being monitored by this test point."
|
||||
::= { rbnVoltageSensorEntry 2 }
|
||||
|
||||
rbnVoltageDesired OBJECT-TYPE
|
||||
SYNTAX RbnVoltage
|
||||
UNITS "millivolts"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The desired voltage level for this test point. If
|
||||
the monitored voltage level (rbnVoltageCurrent) is
|
||||
equal to this value, then the system is performing
|
||||
as designed."
|
||||
::= { rbnVoltageSensorEntry 3 }
|
||||
|
||||
rbnVoltageCurrent OBJECT-TYPE
|
||||
SYNTAX RbnVoltage
|
||||
UNITS "millivolts"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The current voltage level at this test point."
|
||||
::= { rbnVoltageSensorEntry 4 }
|
||||
|
||||
rbnCpuTempSensorTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RbnCpuTempSensorEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"This table contains one row per CPU temperature
|
||||
sensor. Each physical entity in the system may have
|
||||
zero or more CPUs. Each of those CPUs that has a
|
||||
temperature sensor will show up here."
|
||||
::= { rbnEnvMonMIBObjects 4 }
|
||||
|
||||
rbnCpuTempSensorEntry OBJECT-TYPE
|
||||
SYNTAX RbnCpuTempSensorEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"Information about a particular CPU temperature test
|
||||
point."
|
||||
INDEX { entPhysicalIndex, rbnCpuTempIndex }
|
||||
::= { rbnCpuTempSensorTable 1 }
|
||||
|
||||
RbnCpuTempSensorEntry ::= SEQUENCE {
|
||||
rbnCpuTempIndex Integer32,
|
||||
rbnCpuTempDescr DisplayString,
|
||||
rbnCpuTempCurrent RbnTemperature
|
||||
}
|
||||
|
||||
rbnCpuTempIndex OBJECT-TYPE
|
||||
SYNTAX Integer32(1..2147483647)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"An arbitrary value which uniquely identifies a CPU on
|
||||
a particular physical entity. Index values for
|
||||
different CPUs are not necessarily contiguous."
|
||||
::= { rbnCpuTempSensorEntry 1 }
|
||||
|
||||
rbnCpuTempDescr OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..48))
|
||||
MAX-ACCESS read-only
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"The description of a CPU temperature test
|
||||
point. Typically an instance of this object will hold
|
||||
a user-friendly description of the physical entity
|
||||
and a description of the CPU being monitored by this
|
||||
test point."
|
||||
::= { rbnCpuTempSensorEntry 2 }
|
||||
|
||||
rbnCpuTempCurrent OBJECT-TYPE
|
||||
SYNTAX RbnTemperature
|
||||
UNITS "degrees"
|
||||
MAX-ACCESS read-only
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"The current temperature of this CPU."
|
||||
::= { rbnCpuTempSensorEntry 3 }
|
||||
|
||||
rbnFanSpeedTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RbnFanSpeedEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains one row per fan unit within a fan
|
||||
test point."
|
||||
::= { rbnEnvMonMIBObjects 5 }
|
||||
|
||||
rbnFanSpeedEntry OBJECT-TYPE
|
||||
SYNTAX RbnFanSpeedEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Information about a particular fan unit within a fan
|
||||
test point."
|
||||
INDEX { rbnFanIndex, rbnFanUnitID }
|
||||
::= { rbnFanSpeedTable 1 }
|
||||
|
||||
RbnFanSpeedEntry ::= SEQUENCE {
|
||||
rbnFanUnitID Integer32,
|
||||
rbnFanUnitDescr DisplayString,
|
||||
rbnFanSpeedCurrent RbnFanSpeed
|
||||
}
|
||||
|
||||
rbnFanUnitID OBJECT-TYPE
|
||||
SYNTAX Integer32(1..2147483647)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is the fan identification number that describes the
|
||||
specific location of the fan unit within a fan test point."
|
||||
::= { rbnFanSpeedEntry 1 }
|
||||
|
||||
rbnFanUnitDescr OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..32))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The description of the fan unit within a fan test point."
|
||||
::= { rbnFanSpeedEntry 2 }
|
||||
|
||||
rbnFanSpeedCurrent OBJECT-TYPE
|
||||
SYNTAX RbnFanSpeed
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The current speed of this fan unit."
|
||||
::= { rbnFanSpeedEntry 3 }
|
||||
|
||||
rbnEntityTempSensorTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RbnEntityTempSensorEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains one row per temperature
|
||||
sensor on the physical entity."
|
||||
::= { rbnEnvMonMIBObjects 6 }
|
||||
|
||||
rbnEntityTempSensorEntry OBJECT-TYPE
|
||||
SYNTAX RbnEntityTempSensorEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Information about a particular temperature test
|
||||
point."
|
||||
INDEX { entPhysicalIndex, rbnEntityTempIndex }
|
||||
::= { rbnEntityTempSensorTable 1 }
|
||||
|
||||
RbnEntityTempSensorEntry ::= SEQUENCE {
|
||||
rbnEntityTempIndex Integer32,
|
||||
rbnEntityTempDescr DisplayString,
|
||||
rbnEntityTempCurrent RbnTemperature
|
||||
}
|
||||
|
||||
rbnEntityTempIndex OBJECT-TYPE
|
||||
SYNTAX Integer32(1..2147483647)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An arbitrary value which uniquely identifies a
|
||||
particular physical entity. Index values are
|
||||
not necessarily contiguous."
|
||||
::= { rbnEntityTempSensorEntry 1 }
|
||||
|
||||
rbnEntityTempDescr OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE (0..48))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The description of a temperature test
|
||||
point. Typically an instance of this object will hold
|
||||
a user-friendly description of the physical entity
|
||||
being monitored by this test point."
|
||||
::= { rbnEntityTempSensorEntry 2 }
|
||||
|
||||
rbnEntityTempCurrent OBJECT-TYPE
|
||||
SYNTAX RbnTemperature
|
||||
UNITS "degrees Celsius"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The current temperature of this entity in degrees Celsius."
|
||||
::= { rbnEntityTempSensorEntry 3 }
|
||||
|
||||
-- Notifications
|
||||
|
||||
rbnFanFailChange NOTIFICATION-TYPE
|
||||
OBJECTS { rbnFanFail }
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"A rbnFanFailChange notification signifies
|
||||
that the value of an instance of rbnFanFail
|
||||
has changed."
|
||||
::= { rbnEnvMonMIBNotifications 1 }
|
||||
|
||||
rbnPowerFailChange NOTIFICATION-TYPE
|
||||
OBJECTS { rbnPowerFail }
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"A rbnPowerFailChange notification signifies
|
||||
that the value of an instance of rbnPowerFail
|
||||
has changed"
|
||||
::= { rbnEnvMonMIBNotifications 2 }
|
||||
|
||||
rbnFanStatusChange NOTIFICATION-TYPE
|
||||
OBJECTS { rbnFanStatus }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A rbnFanStatusChange notification signifies
|
||||
that the value of an instance of rbnFanStatus
|
||||
has changed."
|
||||
::= { rbnEnvMonMIBNotifications 3 }
|
||||
|
||||
rbnPowerStatusChange NOTIFICATION-TYPE
|
||||
OBJECTS { rbnPowerStatus }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A rbnPowerStatusChange notification signifies
|
||||
that the value of an instance of rbnPowerStatus
|
||||
has changed"
|
||||
::= { rbnEnvMonMIBNotifications 4 }
|
||||
|
||||
-- Conformance Statements
|
||||
|
||||
rbnEnvMonMIBGroups OBJECT IDENTIFIER
|
||||
::= { rbnEnvMonMIBConformance 1 }
|
||||
|
||||
rbnEnvMonMIBCompliances OBJECT IDENTIFIER
|
||||
::= { rbnEnvMonMIBConformance 2 }
|
||||
|
||||
rbnEnvMonMIBObjectGroup OBJECT-GROUP
|
||||
OBJECTS { rbnFanDescr, rbnFanFail,
|
||||
rbnPowerDescr, rbnPowerFail
|
||||
}
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"A collection of objects providing
|
||||
environmental monitor information."
|
||||
::= { rbnEnvMonMIBGroups 1 }
|
||||
|
||||
rbnEnvMonMIBNotificationGroup NOTIFICATION-GROUP
|
||||
NOTIFICATIONS { rbnFanFailChange,
|
||||
rbnPowerFailChange
|
||||
}
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"A collection of notifications providing
|
||||
fan and power environmental monitor information."
|
||||
::= { rbnEnvMonMIBGroups 2 }
|
||||
|
||||
rbnEnvMonVoltageObjectGroup OBJECT-GROUP
|
||||
OBJECTS { rbnVoltageDescr, rbnVoltageDesired,
|
||||
rbnVoltageCurrent
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of objects providing voltage
|
||||
environmental monitor information."
|
||||
::= { rbnEnvMonMIBGroups 3 }
|
||||
|
||||
rbnEnvMonTempObjectGroup OBJECT-GROUP
|
||||
OBJECTS { rbnCpuTempDescr, rbnCpuTempCurrent
|
||||
}
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"A collection of objects providing temperature
|
||||
environmental monitor information."
|
||||
::= { rbnEnvMonMIBGroups 4 }
|
||||
|
||||
rbnEnvMonMIBObjectGroupV2 OBJECT-GROUP
|
||||
OBJECTS { rbnFanDescr, rbnFanStatus,
|
||||
rbnPowerDescr, rbnPowerStatus
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of objects providing
|
||||
environmental monitor information."
|
||||
::= { rbnEnvMonMIBGroups 5 }
|
||||
|
||||
rbnEnvMonMIBNotificationGroupV2 NOTIFICATION-GROUP
|
||||
NOTIFICATIONS { rbnFanStatusChange,
|
||||
rbnPowerStatusChange
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of notifications providing
|
||||
fan and power environmental monitor information."
|
||||
::= { rbnEnvMonMIBGroups 6 }
|
||||
|
||||
rbnEnvMonFanSpeedObjectGroup OBJECT-GROUP
|
||||
OBJECTS { rbnFanUnitDescr, rbnFanSpeedCurrent
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of objects providing fan speed
|
||||
environmental monitor information."
|
||||
::= { rbnEnvMonMIBGroups 7 }
|
||||
|
||||
rbnEnvMonEntityObjectGroup OBJECT-GROUP
|
||||
OBJECTS { rbnEntityTempDescr, rbnEntityTempCurrent
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of objects providing fan speed
|
||||
environmental monitor information."
|
||||
::= { rbnEnvMonMIBGroups 8 }
|
||||
|
||||
rbnEnvMonMIBCompliance MODULE-COMPLIANCE
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"The compliance statement for the EnvMon MIB"
|
||||
MODULE -- this module
|
||||
GROUP rbnEnvMonMIBObjectGroup
|
||||
DESCRIPTION
|
||||
"This group is mandatory for devices which contain
|
||||
Environmental Monitoring capabilities"
|
||||
GROUP rbnEnvMonMIBNotificationGroup
|
||||
DESCRIPTION
|
||||
"This group is mandatory for devices which contain
|
||||
Environmental Monitoring capabilities"
|
||||
::= { rbnEnvMonMIBCompliances 1 }
|
||||
|
||||
rbnEnvMonMIBComplianceV2 MODULE-COMPLIANCE
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"The compliance statement for the EnvMon MIB"
|
||||
|
||||
MODULE -- this module
|
||||
GROUP rbnEnvMonMIBObjectGroup
|
||||
DESCRIPTION
|
||||
"This group is mandatory for devices which contain
|
||||
Environmental Monitoring capabilities"
|
||||
GROUP rbnEnvMonMIBNotificationGroup
|
||||
DESCRIPTION
|
||||
"This group is mandatory for devices which contain
|
||||
Environmental Monitoring capabilities"
|
||||
GROUP rbnEnvMonVoltageObjectGroup
|
||||
DESCRIPTION
|
||||
"This group is mandatory for devices which are capable
|
||||
of sensing system voltages."
|
||||
GROUP rbnEnvMonTempObjectGroup
|
||||
DESCRIPTION
|
||||
"This group is mandatory for devices which are capable
|
||||
of sensing system temperatures."
|
||||
::= { rbnEnvMonMIBCompliances 2 }
|
||||
|
||||
rbnEnvMonMIBComplianceV3 MODULE-COMPLIANCE
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"The compliance statement for the EnvMon MIB"
|
||||
MODULE -- this module
|
||||
GROUP rbnEnvMonMIBObjectGroupV2
|
||||
DESCRIPTION
|
||||
"This group is mandatory for devices which contain
|
||||
Environmental Monitoring capabilities"
|
||||
GROUP rbnEnvMonMIBNotificationGroupV2
|
||||
DESCRIPTION
|
||||
"This group is mandatory for devices which contain
|
||||
Environmental Monitoring capabilities"
|
||||
GROUP rbnEnvMonVoltageObjectGroup
|
||||
DESCRIPTION
|
||||
"This group is mandatory for devices which are capable
|
||||
of sensing system voltages."
|
||||
GROUP rbnEnvMonTempObjectGroup
|
||||
DESCRIPTION
|
||||
"This group is mandatory for devices which are capable
|
||||
of sensing system temperatures."
|
||||
::= { rbnEnvMonMIBCompliances 3 }
|
||||
|
||||
rbnEnvMonMIBComplianceV4 MODULE-COMPLIANCE
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"The compliance statement for the EnvMon MIB"
|
||||
MODULE -- this module
|
||||
GROUP rbnEnvMonMIBObjectGroupV2
|
||||
DESCRIPTION
|
||||
"This group is mandatory for devices which contain
|
||||
Environmental Monitoring capabilities"
|
||||
GROUP rbnEnvMonMIBNotificationGroupV2
|
||||
DESCRIPTION
|
||||
"This group is mandatory for devices which contain
|
||||
Environmental Monitoring capabilities"
|
||||
GROUP rbnEnvMonVoltageObjectGroup
|
||||
DESCRIPTION
|
||||
"This group is mandatory for devices which are capable
|
||||
of sensing system voltages."
|
||||
GROUP rbnEnvMonTempObjectGroup
|
||||
DESCRIPTION
|
||||
"This group is mandatory for devices which are capable
|
||||
of sensing system temperatures."
|
||||
GROUP rbnEnvMonFanSpeedObjectGroup
|
||||
DESCRIPTION
|
||||
"This group is mandatory for SNMP entities which are
|
||||
capable of sensing fan speeds."
|
||||
::= { rbnEnvMonMIBCompliances 4 }
|
||||
|
||||
|
||||
rbnEnvMonMIBComplianceV5 MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The compliance statement for the EnvMon MIB"
|
||||
MODULE -- this module
|
||||
GROUP rbnEnvMonMIBObjectGroupV2
|
||||
DESCRIPTION
|
||||
"This group is mandatory for devices which contain
|
||||
Environmental Monitoring capabilities"
|
||||
GROUP rbnEnvMonMIBNotificationGroupV2
|
||||
DESCRIPTION
|
||||
"This group is mandatory for devices which contain
|
||||
Environmental Monitoring capabilities"
|
||||
GROUP rbnEnvMonVoltageObjectGroup
|
||||
DESCRIPTION
|
||||
"This group is mandatory for devices which are capable
|
||||
of sensing system voltages."
|
||||
GROUP rbnEnvMonFanSpeedObjectGroup
|
||||
DESCRIPTION
|
||||
"This group is mandatory for SNMP entities which are
|
||||
capable of sensing fan speeds."
|
||||
GROUP rbnEnvMonEntityObjectGroup
|
||||
DESCRIPTION
|
||||
"This group is mandatory for devices which contain
|
||||
Environmental Monitoring capabilities, also applicable to SSE
|
||||
card and disks"
|
||||
|
||||
::= { rbnEnvMonMIBCompliances 5 }
|
||||
|
||||