Initial commit
This commit is contained in:
164
MIBS/ericsson/RBN-TC
Normal file
164
MIBS/ericsson/RBN-TC
Normal file
@ -0,0 +1,164 @@
|
||||
-- %DNP% $Id: RBN-TC.my,v 1.1.2.8.252.3 2011/02/22 17:26:18 thatcher Exp $
|
||||
-- %DNP% $Source: /cvsroot/pkt/sw/se/xc/bsd/config/snmp/mibs/Attic/RBN-TC.my,v $
|
||||
-- *****************************************************************
|
||||
-- RBN-TC Textual Convention MIB
|
||||
--
|
||||
-- Copyright (c) 2000, 2002-2009, 2011 Ericsson AB
|
||||
-- All rights reserved.
|
||||
--
|
||||
-- *****************************************************************
|
||||
|
||||
RBN-TC DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY,
|
||||
Integer32, Unsigned32
|
||||
FROM SNMPv2-SMI
|
||||
|
||||
TEXTUAL-CONVENTION
|
||||
FROM SNMPv2-TC
|
||||
|
||||
rbnModules
|
||||
FROM RBN-SMI;
|
||||
|
||||
|
||||
rbnTC MODULE-IDENTITY
|
||||
LAST-UPDATED "201101191800Z" -- Jan 19, 2011
|
||||
ORGANIZATION "Ericsson AB."
|
||||
CONTACT-INFO
|
||||
" Ericsson AB.
|
||||
|
||||
Postal: 100 Headquarters Dr
|
||||
San Jose, CA 95134
|
||||
USA
|
||||
|
||||
Phone: +1 408 750 5000
|
||||
Fax: +1 408 750 5599
|
||||
"
|
||||
DESCRIPTION
|
||||
"Defines common textual conventions used in RBN mib
|
||||
modules."
|
||||
|
||||
REVISION "201101191800Z" -- Jan 19, 2011
|
||||
DESCRIPTION
|
||||
"Update CONTACT-INFO & ORGANIZATION. "
|
||||
|
||||
REVISION "200910201700Z" -- Oct 20, 2009
|
||||
DESCRIPTION
|
||||
"Added new textual convention: RbnUnsigned64 for read-write
|
||||
capable 64 bit integer value."
|
||||
|
||||
REVISION "200406191700Z" -- June 19, 2004
|
||||
DESCRIPTION
|
||||
"Added new textual convention: RbnPortMediumType. Correct
|
||||
warnings given by smilint."
|
||||
|
||||
REVISION "200303171700Z" -- March 17, 2003
|
||||
DESCRIPTION
|
||||
"Added new textual convention: RbnVidOrUntagged."
|
||||
|
||||
REVISION "200211110000Z" -- November 11, 2002
|
||||
DESCRIPTION
|
||||
"Moved definitions of RbnSlot and RbnPort from RBN-PVC-MIB.
|
||||
Updated range on RbnSlot and RbnPort."
|
||||
|
||||
REVISION "200206260000Z" -- June 26, 2002
|
||||
DESCRIPTION
|
||||
"Updated CONTACT-INFO. Added new textual conventions:
|
||||
RbnKBytes and RbnPercentage."
|
||||
|
||||
REVISION "200007140000Z" -- July 14, 2000
|
||||
DESCRIPTION
|
||||
"Initial version."
|
||||
::= { rbnModules 2 }
|
||||
|
||||
|
||||
RbnCircuitHandle ::= TEXTUAL-CONVENTION
|
||||
DISPLAY-HINT "1d:1d:2x-2x-2x"
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A unique identifier for individual circuits. The string is
|
||||
composed of the following:
|
||||
|
||||
Octet 1 slot
|
||||
2 port
|
||||
3-8 circuit identifier
|
||||
|
||||
slots/ports are numbered 0..n. The SMS CLI also numbers slots/ports
|
||||
0..n but SE CLI numbers slots/ports 1..n. For example: When the
|
||||
SE CLI refers to slot/port 1/2, this maps to to the RbnCircuitHandle
|
||||
slot/port 0/1
|
||||
"
|
||||
SYNTAX OCTET STRING (SIZE (8))
|
||||
|
||||
RbnKBytes ::= TEXTUAL-CONVENTION
|
||||
DISPLAY-HINT "d"
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Storage size, expressed in units of 1024 bytes."
|
||||
SYNTAX Integer32 (0..2147483647)
|
||||
|
||||
RbnPercentage ::= TEXTUAL-CONVENTION
|
||||
DISPLAY-HINT "d%"
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This Textual Convention describes an object that stores
|
||||
a whole integer percentage value."
|
||||
SYNTAX Integer32 (0..100)
|
||||
|
||||
RbnSlot ::= TEXTUAL-CONVENTION
|
||||
DISPLAY-HINT "d"
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The chassis slot number. This is the physical slot
|
||||
number as reported in the CLI command 'show hardware'
|
||||
on SMS and the CLI command 'show port' on SE."
|
||||
SYNTAX Unsigned32 (0..255)
|
||||
|
||||
RbnPort ::= TEXTUAL-CONVENTION
|
||||
DISPLAY-HINT "d"
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The chassis port number. This is the physical port
|
||||
number as reported in the CLI command 'show hardware'
|
||||
on SMS and the CLI command 'show port' on SE."
|
||||
SYNTAX Unsigned32 (0..255)
|
||||
|
||||
RbnVidOrUntagged ::= TEXTUAL-CONVENTION
|
||||
DISPLAY-HINT "d"
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The twelve-bit VLAN Identifer (VID) used to uniquely
|
||||
identify the VLAN to which the frame belongs. The VID is
|
||||
encoded as an unsigned binary number. An untagged frame
|
||||
does not carry any identification of the VLAN to which it
|
||||
belongs and is designated with a value of 4096."
|
||||
SYNTAX Integer32 (1..4096)
|
||||
|
||||
RbnPortMediumType ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Medium type of NAS port."
|
||||
SYNTAX INTEGER {
|
||||
unknown(0),
|
||||
dsl(11),
|
||||
cable(12),
|
||||
wireless(13),
|
||||
satellite(14)
|
||||
}
|
||||
|
||||
RbnUnsigned64 ::= TEXTUAL-CONVENTION
|
||||
DISPLAY-HINT "8d"
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unsigned 64 bit integer value is represented as an
|
||||
OCTET STRING. This allows an unsigned integer value in
|
||||
the range 0..18446744073709551615.
|
||||
|
||||
The octets are ordered with the first octet containing
|
||||
the highest ordered bits of the integer and the 8th octet
|
||||
containing the lowest ordered bits, corresponding to
|
||||
network byte order."
|
||||
SYNTAX OCTET STRING (SIZE(8))
|
||||
|
||||
END
|
Reference in New Issue