Initial commit
This commit is contained in:
426
MIBS/fortinet/MERU-VOICE-STATISTICS-MIB
Normal file
426
MIBS/fortinet/MERU-VOICE-STATISTICS-MIB
Normal file
@ -0,0 +1,426 @@
|
||||
-- *****************************************************************
|
||||
-- Meru Networks Enterprise Specific MIB
|
||||
--
|
||||
-- Copyright (c) 2005 by Meru Networks
|
||||
-- All rights reserved
|
||||
--
|
||||
-- *****************************************************************
|
||||
|
||||
MERU-VOICE-STATISTICS-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
NOTIFICATION-TYPE,
|
||||
OBJECT-TYPE,
|
||||
MODULE-IDENTITY,
|
||||
OBJECT-IDENTITY,
|
||||
enterprises,
|
||||
Counter32,
|
||||
Counter64,
|
||||
Gauge32,
|
||||
TimeTicks,
|
||||
IpAddress,
|
||||
Integer32
|
||||
FROM SNMPv2-SMI
|
||||
Ipv6Address
|
||||
FROM IPV6-TC
|
||||
TEXTUAL-CONVENTION,
|
||||
TimeInterval,
|
||||
TimeStamp,
|
||||
DateAndTime,
|
||||
TruthValue,
|
||||
DisplayString,
|
||||
MacAddress,
|
||||
RowStatus
|
||||
FROM SNMPv2-TC
|
||||
mwStatistics
|
||||
FROM MERU-SMI
|
||||
MwlNetProtocol,
|
||||
MwlDeviceType,
|
||||
MwlOnOffSwitch,
|
||||
MwlQosProtocol,
|
||||
MwlQosCallState
|
||||
FROM MERU-TC;
|
||||
|
||||
mwVoiceStatistics MODULE-IDENTITY
|
||||
LAST-UPDATED "200506050000Z"
|
||||
ORGANIZATION "Meru Networks"
|
||||
CONTACT-INFO "support@merunetworks.com"
|
||||
DESCRIPTION
|
||||
"This MIB defines all the managed objects used to manage the Meru WLAN
|
||||
Voice Statistics infrastructure"
|
||||
::= { mwStatistics 3 }
|
||||
|
||||
|
||||
|
||||
mwPhoneTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF MwPhoneEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes Phone Table "
|
||||
::= { mwVoiceStatistics 1 }
|
||||
|
||||
mwPhoneEntry OBJECT-TYPE
|
||||
SYNTAX MwPhoneEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes Phone Table "
|
||||
INDEX { mwPhoneTableIndex }
|
||||
::= { mwPhoneTable 1 }
|
||||
|
||||
MwPhoneEntry ::= SEQUENCE {
|
||||
mwPhoneTableIndex Integer32,
|
||||
mwPhoneIp IpAddress,
|
||||
mwPhoneAp Integer32,
|
||||
mwPhoneMac MacAddress,
|
||||
mwPhoneType MwlQosProtocol,
|
||||
mwPhoneApName DisplayString,
|
||||
mwPhoneServer DisplayString,
|
||||
mwPhoneUsername DisplayString,
|
||||
mwPhoneTransport MwlNetProtocol,
|
||||
mwPhoneDeviceType MwlDeviceType
|
||||
}
|
||||
|
||||
|
||||
mwPhoneTableIndex OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The index value of the table "
|
||||
::= { mwPhoneEntry 1 }
|
||||
|
||||
mwPhoneIp OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes IP Address"
|
||||
::= { mwPhoneEntry 2 }
|
||||
|
||||
mwPhoneAp OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes AP ID"
|
||||
::= { mwPhoneEntry 3 }
|
||||
|
||||
mwPhoneMac OBJECT-TYPE
|
||||
SYNTAX MacAddress
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes MAC Address"
|
||||
::= { mwPhoneEntry 4 }
|
||||
|
||||
mwPhoneType OBJECT-TYPE
|
||||
SYNTAX MwlQosProtocol
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes Protocol Type"
|
||||
::= { mwPhoneEntry 5 }
|
||||
|
||||
mwPhoneApName OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes AP Name"
|
||||
::= { mwPhoneEntry 6 }
|
||||
|
||||
mwPhoneServer OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes Server"
|
||||
::= { mwPhoneEntry 7 }
|
||||
|
||||
mwPhoneUsername OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes Username"
|
||||
::= { mwPhoneEntry 8 }
|
||||
|
||||
mwPhoneTransport OBJECT-TYPE
|
||||
SYNTAX MwlNetProtocol
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes Transport"
|
||||
::= { mwPhoneEntry 9 }
|
||||
|
||||
mwPhoneDeviceType OBJECT-TYPE
|
||||
SYNTAX MwlDeviceType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes Station Type"
|
||||
::= { mwPhoneEntry 10 }
|
||||
|
||||
mwPhoneCallTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF MwPhoneCallEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes Phone Call Table "
|
||||
::= { mwVoiceStatistics 2 }
|
||||
|
||||
mwPhoneCallEntry OBJECT-TYPE
|
||||
SYNTAX MwPhoneCallEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes Phone Call Table "
|
||||
INDEX { mwPhoneCallTableIndex }
|
||||
::= { mwPhoneCallTable 1 }
|
||||
|
||||
MwPhoneCallEntry ::= SEQUENCE {
|
||||
mwPhoneCallTableIndex Integer32,
|
||||
mwPhoneCallToIp IpAddress,
|
||||
mwPhoneCallToAp Integer32,
|
||||
mwPhoneCallType MwlQosProtocol,
|
||||
mwPhoneCallToMac MacAddress,
|
||||
mwPhoneCallState MwlQosCallState,
|
||||
mwPhoneCallFromIp IpAddress,
|
||||
mwPhoneCallFromAp Integer32,
|
||||
mwPhoneCallFromMac MacAddress,
|
||||
mwPhoneCallToApName DisplayString,
|
||||
mwPhoneCallToFlowtag Integer32,
|
||||
mwPhoneCallToPending MwlOnOffSwitch,
|
||||
mwPhoneCallFromApName DisplayString,
|
||||
mwPhoneCallToUsername DisplayString,
|
||||
mwPhoneCallFromFlowtag Integer32,
|
||||
mwPhoneCallFromPending MwlOnOffSwitch,
|
||||
mwPhoneCallFromUsername DisplayString
|
||||
}
|
||||
|
||||
|
||||
mwPhoneCallTableIndex OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The index value of the table "
|
||||
::= { mwPhoneCallEntry 1 }
|
||||
|
||||
mwPhoneCallToIp OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes To IP Address"
|
||||
::= { mwPhoneCallEntry 2 }
|
||||
|
||||
mwPhoneCallToAp OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes To AP ID"
|
||||
::= { mwPhoneCallEntry 3 }
|
||||
|
||||
mwPhoneCallType OBJECT-TYPE
|
||||
SYNTAX MwlQosProtocol
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes Protocol Type"
|
||||
::= { mwPhoneCallEntry 4 }
|
||||
|
||||
mwPhoneCallToMac OBJECT-TYPE
|
||||
SYNTAX MacAddress
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes To MAC Address"
|
||||
::= { mwPhoneCallEntry 5 }
|
||||
|
||||
mwPhoneCallState OBJECT-TYPE
|
||||
SYNTAX MwlQosCallState
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes Call state"
|
||||
::= { mwPhoneCallEntry 6 }
|
||||
|
||||
mwPhoneCallFromIp OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes From IP Address"
|
||||
::= { mwPhoneCallEntry 7 }
|
||||
|
||||
mwPhoneCallFromAp OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes From AP ID"
|
||||
::= { mwPhoneCallEntry 8 }
|
||||
|
||||
mwPhoneCallFromMac OBJECT-TYPE
|
||||
SYNTAX MacAddress
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes From MAC Address"
|
||||
::= { mwPhoneCallEntry 9 }
|
||||
|
||||
mwPhoneCallToApName OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes To AP Name"
|
||||
::= { mwPhoneCallEntry 10 }
|
||||
|
||||
mwPhoneCallToFlowtag OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes To Flow Tag"
|
||||
::= { mwPhoneCallEntry 11 }
|
||||
|
||||
mwPhoneCallToPending OBJECT-TYPE
|
||||
SYNTAX MwlOnOffSwitch
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes To Qos Pending"
|
||||
::= { mwPhoneCallEntry 12 }
|
||||
|
||||
mwPhoneCallFromApName OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes From AP Name"
|
||||
::= { mwPhoneCallEntry 13 }
|
||||
|
||||
mwPhoneCallToUsername OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes To Username"
|
||||
::= { mwPhoneCallEntry 14 }
|
||||
|
||||
mwPhoneCallFromFlowtag OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes From Flow Tag"
|
||||
::= { mwPhoneCallEntry 15 }
|
||||
|
||||
mwPhoneCallFromPending OBJECT-TYPE
|
||||
SYNTAX MwlOnOffSwitch
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes From Qos Pending"
|
||||
::= { mwPhoneCallEntry 16 }
|
||||
|
||||
mwPhoneCallFromUsername OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes From Username"
|
||||
::= { mwPhoneCallEntry 17 }
|
||||
|
||||
mwVoiceStatusTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF MwVoiceStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes Voice Status Table "
|
||||
::= { mwVoiceStatistics 3 }
|
||||
|
||||
mwVoiceStatusEntry OBJECT-TYPE
|
||||
SYNTAX MwVoiceStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes Voice Status Table "
|
||||
INDEX { mwVoiceStatusTableIndex }
|
||||
::= { mwVoiceStatusTable 1 }
|
||||
|
||||
MwVoiceStatusEntry ::= SEQUENCE {
|
||||
mwVoiceStatusTableIndex Integer32,
|
||||
mwVoiceStatusAp Integer32,
|
||||
mwVoiceStatusApName DisplayString,
|
||||
mwVoiceStatusPhoneCount Unsigned32,
|
||||
mwVoiceStatusRejectCount Counter64,
|
||||
mwVoiceStatusActiveCallCount Unsigned32,
|
||||
mwVoiceStatusPendingCallCount Unsigned32
|
||||
}
|
||||
|
||||
|
||||
mwVoiceStatusTableIndex OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The index value of the table "
|
||||
::= { mwVoiceStatusEntry 1 }
|
||||
|
||||
mwVoiceStatusAp OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes AP ID"
|
||||
::= { mwVoiceStatusEntry 2 }
|
||||
|
||||
mwVoiceStatusApName OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes AP Name"
|
||||
::= { mwVoiceStatusEntry 3 }
|
||||
|
||||
mwVoiceStatusPhoneCount OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes Phone Count"
|
||||
::= { mwVoiceStatusEntry 4 }
|
||||
|
||||
mwVoiceStatusRejectCount OBJECT-TYPE
|
||||
SYNTAX Counter64
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes Call Rejected Count"
|
||||
::= { mwVoiceStatusEntry 5 }
|
||||
|
||||
mwVoiceStatusActiveCallCount OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes Active Call Count"
|
||||
::= { mwVoiceStatusEntry 6 }
|
||||
|
||||
mwVoiceStatusPendingCallCount OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object describes Qos Pending Call Count"
|
||||
::= { mwVoiceStatusEntry 7 }
|
||||
|
||||
|
||||
END
|
||||
|
Reference in New Issue
Block a user