Initial commit
This commit is contained in:
279
MIBS/gemds/MDS-SYSTEM-MIB
Normal file
279
MIBS/gemds/MDS-SYSTEM-MIB
Normal file
@ -0,0 +1,279 @@
|
||||
MDS-SYSTEM-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY,
|
||||
OBJECT-TYPE,
|
||||
Integer32,
|
||||
Unsigned32
|
||||
FROM SNMPv2-SMI
|
||||
TEXTUAL-CONVENTION,
|
||||
TruthValue,DateAndTime
|
||||
FROM SNMPv2-TC
|
||||
MODULE-COMPLIANCE,
|
||||
OBJECT-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
mdsSystem
|
||||
FROM MDS-ORBIT-SMI-MIB;
|
||||
|
||||
mdsSystemMIB MODULE-IDENTITY
|
||||
LAST-UPDATED "201805160000Z" -- May 16, 2018
|
||||
ORGANIZATION
|
||||
"GE MDS LLC
|
||||
http://www.gemds.com"
|
||||
CONTACT-INFO
|
||||
"T 1-800-474-0694 (Toll Free in North America)
|
||||
T 585-242-9600
|
||||
F 585-242-9620
|
||||
|
||||
175 Science Parkway
|
||||
Rochester, New York 14620
|
||||
USA"
|
||||
DESCRIPTION
|
||||
"The MIB module to describe the system."
|
||||
REVISION "201911180000Z"
|
||||
DESCRIPTION
|
||||
"Added boot and current time."
|
||||
REVISION "201805160000Z"
|
||||
DESCRIPTION
|
||||
"Updated conformance statments based on smilint."
|
||||
REVISION "201402100000Z"
|
||||
DESCRIPTION
|
||||
"Initial version."
|
||||
::= { mdsSystem 1 }
|
||||
|
||||
mSysMIBObjects OBJECT IDENTIFIER
|
||||
::= { mdsSystemMIB 1 }
|
||||
|
||||
mSysConfig OBJECT IDENTIFIER
|
||||
::= { mSysMIBObjects 1 }
|
||||
|
||||
mSysStatus OBJECT IDENTIFIER
|
||||
::= { mSysMIBObjects 2 }
|
||||
|
||||
-- Textual Conventions
|
||||
FirmwareLocation ::= TEXTUAL-CONVENTION
|
||||
DISPLAY-HINT "d"
|
||||
STATUS current
|
||||
DESCRIPTION "FirmwareLocation"
|
||||
SYNTAX Unsigned32 (0 .. 255)
|
||||
|
||||
-- System Status Objects
|
||||
mSysSerialNumberCore OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Core board serial number."
|
||||
::= { mSysStatus 1 }
|
||||
|
||||
mSysSerialNumberPlatform OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Platform board serial number."
|
||||
::= { mSysStatus 2 }
|
||||
|
||||
mSysProductConfiguration OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Product configuration."
|
||||
::= { mSysStatus 3 }
|
||||
|
||||
mSysGuid OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "GUID of the unit."
|
||||
::= { mSysStatus 4 }
|
||||
|
||||
mSysUptime OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "System uptime (in secs) since bootup."
|
||||
::= { mSysStatus 5 }
|
||||
|
||||
mSysTemperature OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "System temperature (in Celsius)."
|
||||
::= { mSysStatus 6 }
|
||||
|
||||
mSysFirmwareVersionTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF MSysFirmwareVersionEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains status of system firmware."
|
||||
::= { mSysStatus 7 }
|
||||
|
||||
mSysPowerSupplyVoltage OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Power Supply Voltage (in VDC)."
|
||||
::= { mSysStatus 9 }
|
||||
|
||||
mSysCurrentDateTime OBJECT-TYPE
|
||||
SYNTAX DateAndTime
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Current system date and time."
|
||||
::= { mSysStatus 10 }
|
||||
|
||||
mSysBootDateTime OBJECT-TYPE
|
||||
SYNTAX DateAndTime
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "system date and time on boot."
|
||||
::= { mSysStatus 11 }
|
||||
|
||||
mSysFirmwareVersionEntry OBJECT-TYPE
|
||||
SYNTAX MSysFirmwareVersionEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Each entry contains information about the stored firmware image."
|
||||
INDEX { mSysLocation }
|
||||
::= { mSysFirmwareVersionTable 1 }
|
||||
|
||||
MSysFirmwareVersionEntry ::=
|
||||
SEQUENCE {
|
||||
mSysLocation FirmwareLocation,
|
||||
mSysVersion OCTET STRING,
|
||||
mSysActive TruthValue
|
||||
}
|
||||
|
||||
mSysLocation OBJECT-TYPE
|
||||
SYNTAX FirmwareLocation
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Firmware location."
|
||||
::= { mSysFirmwareVersionEntry 1 }
|
||||
|
||||
mSysVersion OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Firmware version."
|
||||
::= { mSysFirmwareVersionEntry 2 }
|
||||
|
||||
mSysActive OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Firmware state."
|
||||
::= { mSysFirmwareVersionEntry 3 }
|
||||
|
||||
mSysAutoUpdateState OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Current state of the auto-update daemon."
|
||||
::= { mSysStatus 12 }
|
||||
|
||||
mSysAutoUpdateDetails OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "Detailed information on auto-update state."
|
||||
::= { mSysStatus 13 }
|
||||
|
||||
-- OIDs in the mSysMprStatus subtree only exists on MPR devices.
|
||||
mSysMprStatus OBJECT IDENTIFIER
|
||||
::= { mSysStatus 8 }
|
||||
|
||||
mSysMprHeatsinkTemperature1 OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "The current heatsink #1 temperature in degrees Celsius."
|
||||
::= { mSysMprStatus 1 }
|
||||
|
||||
mSysMprHeatsinkTemperature2 OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "The current heatsink #2 temperature in degrees Celsius."
|
||||
::= { mSysMprStatus 2 }
|
||||
|
||||
mSysMprPowerSupplyVoltage1 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "The current output voltage of power supply #1."
|
||||
::= { mSysMprStatus 3 }
|
||||
|
||||
mSysMprPowerSupplyVoltage2 OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "The current output voltage of power supply #2."
|
||||
::= { mSysMprStatus 4 }
|
||||
|
||||
mSysMprRelaySwitchPosition OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "The current state of the manual override switch on the relay card."
|
||||
::= { mSysMprStatus 5 }
|
||||
|
||||
-- conformance information
|
||||
mdsSysMIBConformance OBJECT IDENTIFIER ::= { mdsSystemMIB 3 }
|
||||
mdsSysMIBCompliances OBJECT IDENTIFIER ::= { mdsSysMIBConformance 1 }
|
||||
mdsSysMIBGroups OBJECT IDENTIFIER ::= { mdsSysMIBConformance 2 }
|
||||
|
||||
-- compliance statements
|
||||
mSysCompliance MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The compliance statement for SNMP entities that
|
||||
implement the MDS-SYSTEM-MIB."
|
||||
MODULE -- this module
|
||||
MANDATORY-GROUPS {
|
||||
mSysStatusGroup
|
||||
}
|
||||
GROUP mSysMprStatusGroup
|
||||
DESCRIPTION
|
||||
"This group is for SNMP entities that
|
||||
support Orbit MPR status."
|
||||
|
||||
::= { mdsSysMIBCompliances 1 }
|
||||
|
||||
-- units of conformance
|
||||
mSysStatusGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
mSysSerialNumberCore,
|
||||
mSysSerialNumberPlatform,
|
||||
mSysProductConfiguration,
|
||||
mSysGuid,
|
||||
mSysUptime,
|
||||
mSysTemperature,
|
||||
mSysPowerSupplyVoltage,
|
||||
mSysLocation,
|
||||
mSysVersion,
|
||||
mSysActive
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of objects providing information about
|
||||
Orbit system status."
|
||||
::= { mdsSysMIBGroups 1 }
|
||||
|
||||
mSysMprStatusGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
mSysMprHeatsinkTemperature1,
|
||||
mSysMprHeatsinkTemperature2,
|
||||
mSysMprPowerSupplyVoltage1,
|
||||
mSysMprPowerSupplyVoltage2,
|
||||
mSysMprRelaySwitchPosition
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of objects providing information about
|
||||
Orbit MPR system status."
|
||||
::= { mdsSysMIBGroups 2 }
|
||||
|
||||
END
|
Reference in New Issue