Initial commit
This commit is contained in:
164
MIBS/hillstone/HILLSTONE-SYSTEM-MIB
Normal file
164
MIBS/hillstone/HILLSTONE-SYSTEM-MIB
Normal file
@ -0,0 +1,164 @@
|
||||
-- **********************************************************************
|
||||
-- HILLSTONE-SYSTEM-MIB
|
||||
--
|
||||
-- Copyright (c) 2009 by Hillstone Networks, Inc.
|
||||
-- All rights reserved.
|
||||
--
|
||||
-- Version: V3
|
||||
-- Description: Hillstone Networks SYSTEM MIB Object Identifier Assignments
|
||||
-- **********************************************************************
|
||||
--
|
||||
|
||||
HILLSTONE-SYSTEM-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY FROM SNMPv2-SMI
|
||||
NetworkAddress, IpAddress,
|
||||
Counter, Gauge, TimeTicks FROM RFC1155-SMI
|
||||
TruthValue FROM SNMPv2-TC
|
||||
hillstoneSys FROM HILLSTONE-SMI;
|
||||
|
||||
-- textual conventions
|
||||
|
||||
DisplayString ::=
|
||||
OCTET STRING
|
||||
-- This data type is used to model textual information taken
|
||||
-- from the NVT ASCII character set. By convention, objects
|
||||
-- with this syntax are declared as having
|
||||
--
|
||||
-- SIZE (0..255)
|
||||
|
||||
hillstoneSysMibObjects OBJECT IDENTIFIER ::= { hillstoneSys 1 }
|
||||
|
||||
-- hillstone systems
|
||||
sysSerialNumber OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
::= { hillstoneSysMibObjects 1 }
|
||||
|
||||
sysSoftware OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
::= { hillstoneSysMibObjects 2 }
|
||||
|
||||
sysCPU OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
::= { hillstoneSysMibObjects 3 }
|
||||
|
||||
sysTotalMemory OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
::= { hillstoneSysMibObjects 4 }
|
||||
|
||||
sysCurMemory OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
::= { hillstoneSysMibObjects 5 }
|
||||
|
||||
sysTotalSession OBJECT-TYPE
|
||||
SYNTAX Counter
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
::= { hillstoneSysMibObjects 6 }
|
||||
|
||||
sysCurSession OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
::= { hillstoneSysMibObjects 7 }
|
||||
|
||||
sysHAStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
none (0),
|
||||
init (1),
|
||||
hello (2),
|
||||
backup (3),
|
||||
master (4),
|
||||
slase (5),
|
||||
AA-mode (6)
|
||||
}
|
||||
ACCESS read-only
|
||||
STATUS mandatory
|
||||
::= { hillstoneSysMibObjects 8 }
|
||||
|
||||
sysSnmpStackStatus OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The running status of snmp Stack."
|
||||
::= { hillstoneSysMibObjects 9 }
|
||||
|
||||
sysTr069StackStatus OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The running status of tr069 stack."
|
||||
::= { hillstoneSysMibObjects 10 }
|
||||
|
||||
sysVedorOUI OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The oui code of the Tr069 stack.."
|
||||
::= { hillstoneSysMibObjects 11 }
|
||||
|
||||
sysLogStackStatus OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The running status of syslog stack."
|
||||
::= { hillstoneSysMibObjects 12 }
|
||||
|
||||
sysLogServerAddress1 OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The syslog receiver addrees 1."
|
||||
::= { hillstoneSysMibObjects 13 }
|
||||
|
||||
sysLogServerAddress2 OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The syslog receiver addrees 2."
|
||||
::= { hillstoneSysMibObjects 14 }
|
||||
|
||||
sysDeviceReloadAction OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
reloadUnAvailable(1),
|
||||
reloadAtOnce(2)
|
||||
}
|
||||
ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The actioin of reloading the device. when the value is set to 2,the device will reboot at once."
|
||||
::= { hillstoneSysMibObjects 15 }
|
||||
|
||||
sysStatisticsPeriod OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
oneDay(1)
|
||||
}
|
||||
ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The period of statistics. default statistics period is 24hours"
|
||||
::= { hillstoneSysMibObjects 16 }
|
||||
|
||||
|
||||
END
|
||||
|