ETHER-WIS DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, OBJECT-TYPE,
|
||||
Gauge32, transmission
|
||||
FROM SNMPv2-SMI
|
||||
ifIndex
|
||||
FROM IF-MIB
|
||||
MODULE-COMPLIANCE, OBJECT-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
sonetMediumStuff2, sonetSectionStuff2,
|
||||
sonetLineStuff2, sonetFarEndLineStuff2,
|
||||
sonetPathStuff2, sonetFarEndPathStuff2,
|
||||
sonetMediumType, sonetMediumLineCoding,
|
||||
sonetMediumLineType, sonetMediumCircuitIdentifier,
|
||||
sonetMediumLoopbackConfig, sonetSESthresholdSet,
|
||||
sonetPathCurrentWidth
|
||||
FROM SONET-MIB;
|
||||
|
||||
etherWisMIB MODULE-IDENTITY
|
||||
LAST-UPDATED "200309190000Z" -- September 19, 2003
|
||||
ORGANIZATION "IETF Ethernet Interfaces and Hub MIB
|
||||
Working Group"
|
||||
CONTACT-INFO
|
||||
"WG charter:
|
||||
http://www.ietf.org/html.charters/hubmib-charter.html
|
||||
|
||||
Mailing Lists:
|
||||
General Discussion: hubmib@ietf.org <mailto:hubmib@ietf.org>
|
||||
To Subscribe: hubmib-request@ietf.org <mailto:hubmib-request@ietf.org>
|
||||
In Body: subscribe your_email_address
|
||||
|
||||
Chair: Dan Romascanu
|
||||
Postal: Avaya Inc.
|
||||
Atidim Technology Park, Bldg. 3
|
||||
Tel Aviv 61131
|
||||
Israel
|
||||
Tel: +972 3 645 8414
|
||||
E-mail: dromasca@avaya.com <mailto:dromasca@avaya.com>
|
||||
|
||||
Editor: C. M. Heard
|
||||
Postal: 600 Rainbow Dr. #141
|
||||
Mountain View, CA 94041-2542
|
||||
USA
|
||||
Tel: +1 650-964-8391
|
||||
E-mail: heard@pobox.com <mailto:heard@pobox.com>"
|
||||
|
||||
DESCRIPTION
|
||||
"The objects in this MIB module are used in conjunction
|
||||
with objects in the SONET-MIB and the MAU-MIB to manage
|
||||
the Ethernet WAN Interface Sublayer (WIS).
|
||||
|
||||
The following reference is used throughout this MIB module:
|
||||
|
||||
[IEEE 802.3 Std] refers to:
|
||||
IEEE Std 802.3, 2000 Edition: 'IEEE Standard for
|
||||
Information technology - Telecommunications and
|
||||
information exchange between systems - Local and
|
||||
metropolitan area networks - Specific requirements -
|
||||
Part 3: Carrier sense multiple access with collision
|
||||
detection (CSMA/CD) access method and physical layer
|
||||
specifications', as amended by IEEE Std 802.3ae-2002,
|
||||
'IEEE Standard for Carrier Sense Multiple Access with
|
||||
Collision Detection (CSMA/CD) Access Method and
|
||||
Physical Layer Specifications - Media Access Control
|
||||
(MAC) Parameters, Physical Layer and Management
|
||||
Parameters for 10 Gb/s Operation', 30 August 2002.
|
||||
|
||||
Of particular interest are Clause 50, 'WAN Interface
|
||||
Sublayer (WIS), type 10GBASE-W', Clause 30, '10Mb/s,
|
||||
100Mb/s, 1000Mb/s, and 10Gb/s MAC Control, and Link
|
||||
Aggregation Management', and Clause 45, 'Management
|
||||
Data Input/Output (MDIO) Interface'.
|
||||
|
||||
Copyright (C) The Internet Society (2003). This version
|
||||
of this MIB module is part of RFC 3637 </rfcs/rfc3637.html>; see the RFC
|
||||
itself for full legal notices."
|
||||
|
||||
REVISION "200309190000Z" -- September 19, 2003
|
||||
DESCRIPTION "Initial version, published as RFC 3637 </rfcs/rfc3637.html>."
|
||||
|
||||
::= { transmission 134 }
|
||||
|
||||
-- The main sections of the module
|
||||
|
||||
etherWisObjects OBJECT IDENTIFIER ::= { etherWisMIB 1 }
|
||||
|
||||
etherWisObjectsPath OBJECT IDENTIFIER ::= { etherWisMIB 2 }
|
||||
|
||||
etherWisConformance OBJECT IDENTIFIER ::= { etherWisMIB 3 }
|
||||
|
||||
-- groups in the Ethernet WIS MIB module
|
||||
|
||||
etherWisDevice OBJECT IDENTIFIER ::= { etherWisObjects 1 }
|
||||
|
||||
etherWisSection OBJECT IDENTIFIER ::= { etherWisObjects 2 }
|
||||
|
||||
etherWisPath OBJECT IDENTIFIER ::= { etherWisObjectsPath 1 }
|
||||
|
||||
etherWisFarEndPath OBJECT IDENTIFIER ::= { etherWisObjectsPath 2 }
|
||||
|
||||
-- The Device group
|
||||
|
||||
-- These objects provide WIS extensions to
|
||||
-- the SONET-MIB Medium Group.
|
||||
|
||||
etherWisDeviceTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF EtherWisDeviceEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table for Ethernet WIS devices"
|
||||
::= { etherWisDevice 1 }
|
||||
|
||||
etherWisDeviceEntry OBJECT-TYPE
|
||||
SYNTAX EtherWisDeviceEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the Ethernet WIS device table. For each
|
||||
instance of this object there MUST be a corresponding
|
||||
instance of sonetMediumEntry."
|
||||
INDEX { ifIndex }
|
||||
::= { etherWisDeviceTable 1 }
|
||||
|
||||
EtherWisDeviceEntry ::=
|
||||
SEQUENCE {
|
||||
etherWisDeviceTxTestPatternMode INTEGER,
|
||||
etherWisDeviceRxTestPatternMode INTEGER,
|
||||
etherWisDeviceRxTestPatternErrors Gauge32
|
||||
}
|
||||
|
||||
etherWisDeviceTxTestPatternMode OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
none(1),
|
||||
squareWave(2),
|
||||
prbs31(3),
|
||||
mixedFrequency(4)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable controls the transmit test pattern mode.
|
||||
The value none(1) puts the the WIS transmit path into
|
||||
the normal operating mode. The value squareWave(2) puts
|
||||
the WIS transmit path into the square wave test pattern
|
||||
mode described in [IEEE 802.3 Std.] subclause 50.3.8.1.
|
||||
The value prbs31(3) puts the WIS transmit path into the
|
||||
PRBS31 test pattern mode described in [IEEE 802.3 Std.]
|
||||
subclause 50.3.8.2. The value mixedFrequency(4) puts the
|
||||
WIS transmit path into the mixed frequency test pattern
|
||||
mode described in [IEEE 802.3 Std.] subclause 50.3.8.3.
|
||||
Any attempt to set this object to a value other than
|
||||
none(1) when the corresponding instance of ifAdminStatus
|
||||
has the value up(1) MUST be rejected with the error
|
||||
inconsistentValue, and any attempt to set the corresponding
|
||||
instance of ifAdminStatus to the value up(1) when an
|
||||
instance of this object has a value other than none(1)
|
||||
MUST be rejected with the error inconsistentValue."
|
||||
REFERENCE
|
||||
"[IEEE 802.3 Std.], 50.3.8, WIS test pattern generator and
|
||||
checker, 45.2.2.6, 10G WIS control 2 register (2.7), and
|
||||
45.2.2.7.2, PRBS31 pattern testing ability (2.8.1)."
|
||||
::= { etherWisDeviceEntry 1 }
|
||||
|
||||
etherWisDeviceRxTestPatternMode OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
none(1),
|
||||
prbs31(3),
|
||||
mixedFrequency(4)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
|
||||
DESCRIPTION
|
||||
"This variable controls the receive test pattern mode.
|
||||
The value none(1) puts the the WIS receive path into the
|
||||
normal operating mode. The value prbs31(3) puts the WIS
|
||||
receive path into the PRBS31 test pattern mode described
|
||||
in [IEEE 802.3 Std.] subclause 50.3.8.2. The value
|
||||
mixedFrequency(4) puts the WIS receive path into the mixed
|
||||
frequency test pattern mode described in [IEEE 802.3 Std.]
|
||||
subclause 50.3.8.3. Any attempt to set this object to a
|
||||
value other than none(1) when the corresponding instance
|
||||
of ifAdminStatus has the value up(1) MUST be rejected with
|
||||
the error inconsistentValue, and any attempt to set the
|
||||
corresponding instance of ifAdminStatus to the value up(1)
|
||||
when an instance of this object has a value other than
|
||||
none(1) MUST be rejected with the error inconsistentValue."
|
||||
REFERENCE
|
||||
"[IEEE 802.3 Std.], 50.3.8, WIS test pattern generator and
|
||||
checker, 45.2.2.6, 10G WIS control 2 register (2.7), and
|
||||
45.2.2.7.2, PRBS31 pattern testing ability (2.8.1)."
|
||||
::= { etherWisDeviceEntry 2 }
|
||||
|
||||
etherWisDeviceRxTestPatternErrors OBJECT-TYPE
|
||||
SYNTAX Gauge32 ( 0..65535 )
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object counts the number of errors detected when the
|
||||
WIS receive path is operating in the PRBS31 test pattern
|
||||
mode. It is reset to zero when the WIS receive path
|
||||
initially enters that mode, and it increments each time
|
||||
the PRBS pattern checker detects an error as described in
|
||||
[IEEE 802.3 Std.] subclause 50.3.8.2 unless its value is
|
||||
65535, in which case it remains unchanged. This object is
|
||||
writeable so that it may be reset upon explicit request
|
||||
of a command generator application while the WIS receive
|
||||
path continues to operate in PRBS31 test pattern mode."
|
||||
REFERENCE
|
||||
"[IEEE 802.3 Std.], 50.3.8, WIS test pattern generator and
|
||||
checker, 45.2.2.7.2, PRBS31 pattern testing ability
|
||||
(2.8.1), and 45.2.2.8, 10G WIS test pattern error counter
|
||||
register (2.9)."
|
||||
::= { etherWisDeviceEntry 3 }
|
||||
|
||||
-- The Section group
|
||||
|
||||
-- These objects provide WIS extensions to
|
||||
-- the SONET-MIB Section Group.
|
||||
|
||||
etherWisSectionCurrentTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF EtherWisSectionCurrentEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table for the current state of Ethernet WIS sections."
|
||||
::= { etherWisSection 1 }
|
||||
|
||||
etherWisSectionCurrentEntry OBJECT-TYPE
|
||||
SYNTAX EtherWisSectionCurrentEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the etherWisSectionCurrentTable. For each
|
||||
instance of this object there MUST be a corresponding
|
||||
instance of sonetSectionCurrentEntry."
|
||||
INDEX { ifIndex }
|
||||
::= { etherWisSectionCurrentTable 1 }
|
||||
|
||||
EtherWisSectionCurrentEntry ::=
|
||||
SEQUENCE {
|
||||
etherWisSectionCurrentJ0Transmitted OCTET STRING,
|
||||
etherWisSectionCurrentJ0Received OCTET STRING
|
||||
}
|
||||
|
||||
etherWisSectionCurrentJ0Transmitted OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (16))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is the 16-octet section trace message that
|
||||
is transmitted in the J0 byte. The value SHOULD
|
||||
be '89'h followed by fifteen octets of '00'h
|
||||
(or some cyclic shift thereof) when the section
|
||||
trace function is not used, and the implementation
|
||||
SHOULD use that value (or a cyclic shift thereof)
|
||||
as a default if no other value has been set."
|
||||
REFERENCE
|
||||
"[IEEE 802.3 Std.], 30.8.1.1.8, aJ0ValueTX."
|
||||
::= { etherWisSectionCurrentEntry 1 }
|
||||
|
||||
etherWisSectionCurrentJ0Received OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (16))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is the 16-octet section trace message that
|
||||
was most recently received in the J0 byte."
|
||||
REFERENCE
|
||||
"[IEEE 802.3 Std.], 30.8.1.1.9, aJ0ValueRX."
|
||||
::= { etherWisSectionCurrentEntry 2 }
|
||||
|
||||
-- The Path group
|
||||
|
||||
-- These objects provide WIS extensions to
|
||||
-- the SONET-MIB Path Group.
|
||||
|
||||
etherWisPathCurrentTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF EtherWisPathCurrentEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table for the current state of Ethernet WIS paths."
|
||||
::= { etherWisPath 1 }
|
||||
|
||||
etherWisPathCurrentEntry OBJECT-TYPE
|
||||
SYNTAX EtherWisPathCurrentEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the etherWisPathCurrentTable. For each
|
||||
instance of this object there MUST be a corresponding
|
||||
instance of sonetPathCurrentEntry."
|
||||
INDEX { ifIndex }
|
||||
::= { etherWisPathCurrentTable 1 }
|
||||
|
||||
EtherWisPathCurrentEntry ::=
|
||||
SEQUENCE {
|
||||
etherWisPathCurrentStatus BITS,
|
||||
etherWisPathCurrentJ1Transmitted OCTET STRING,
|
||||
etherWisPathCurrentJ1Received OCTET STRING
|
||||
}
|
||||
|
||||
etherWisPathCurrentStatus OBJECT-TYPE
|
||||
SYNTAX BITS {
|
||||
etherWisPathLOP(0),
|
||||
etherWisPathAIS(1),
|
||||
etherWisPathPLM(2),
|
||||
etherWisPathLCD(3)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the current status of the
|
||||
path payload with a bit map that can indicate multiple
|
||||
defects at once. The bit positions are assigned as
|
||||
follows:
|
||||
|
||||
etherWisPathLOP(0)
|
||||
This bit is set to indicate that an
|
||||
LOP-P (Loss of Pointer - Path) defect
|
||||
is being experienced. Note: when this
|
||||
bit is set, sonetPathSTSLOP MUST be set
|
||||
in the corresponding instance of
|
||||
sonetPathCurrentStatus.
|
||||
|
||||
etherWisPathAIS(1)
|
||||
This bit is set to indicate that an
|
||||
AIS-P (Alarm Indication Signal - Path)
|
||||
defect is being experienced. Note: when
|
||||
this bit is set, sonetPathSTSAIS MUST be
|
||||
set in the corresponding instance of
|
||||
sonetPathCurrentStatus.
|
||||
|
||||
etherWisPathPLM(1)
|
||||
This bit is set to indicate that a
|
||||
PLM-P (Payload Label Mismatch - Path)
|
||||
defect is being experienced. Note: when
|
||||
this bit is set, sonetPathSignalLabelMismatch
|
||||
MUST be set in the corresponding instance of
|
||||
sonetPathCurrentStatus.
|
||||
|
||||
etherWisPathLCD(3)
|
||||
This bit is set to indicate that an
|
||||
LCD-P (Loss of Codegroup Delination - Path)
|
||||
defect is being experienced. Since this
|
||||
defect is detected by the PCS and not by
|
||||
the path layer itself, there is no
|
||||
corresponding bit in sonetPathCurrentStatus."
|
||||
REFERENCE
|
||||
"[IEEE 802.3 Std.], 30.8.1.1.18, aPathStatus."
|
||||
::= { etherWisPathCurrentEntry 1 }
|
||||
|
||||
etherWisPathCurrentJ1Transmitted OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (16))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is the 16-octet path trace message that
|
||||
is transmitted in the J1 byte. The value SHOULD
|
||||
be '89'h followed by fifteen octets of '00'h
|
||||
(or some cyclic shift thereof) when the path
|
||||
trace function is not used, and the implementation
|
||||
SHOULD use that value (or a cyclic shift thereof)
|
||||
as a default if no other value has been set."
|
||||
REFERENCE
|
||||
"[IEEE 802.3 Std.], 30.8.1.1.23, aJ1ValueTX."
|
||||
::= { etherWisPathCurrentEntry 2 }
|
||||
|
||||
etherWisPathCurrentJ1Received OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (16))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is the 16-octet path trace message that
|
||||
was most recently received in the J1 byte."
|
||||
REFERENCE
|
||||
"[IEEE 802.3 Std.], 30.8.1.1.24, aJ1ValueRX."
|
||||
::= { etherWisPathCurrentEntry 3 }
|
||||
|
||||
-- The Far End Path group
|
||||
|
||||
-- These objects provide WIS extensions to
|
||||
-- the SONET-MIB Far End Path Group.
|
||||
|
||||
etherWisFarEndPathCurrentTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF EtherWisFarEndPathCurrentEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The table for the current far-end state of Ethernet WIS
|
||||
paths."
|
||||
::= { etherWisFarEndPath 1 }
|
||||
|
||||
etherWisFarEndPathCurrentEntry OBJECT-TYPE
|
||||
SYNTAX EtherWisFarEndPathCurrentEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the etherWisFarEndPathCurrentTable. For each
|
||||
instance of this object there MUST be a corresponding
|
||||
instance of sonetFarEndPathCurrentEntry."
|
||||
INDEX { ifIndex }
|
||||
::= { etherWisFarEndPathCurrentTable 1 }
|
||||
|
||||
EtherWisFarEndPathCurrentEntry ::=
|
||||
SEQUENCE {
|
||||
etherWisFarEndPathCurrentStatus BITS
|
||||
}
|
||||
|
||||
etherWisFarEndPathCurrentStatus OBJECT-TYPE
|
||||
SYNTAX BITS {
|
||||
etherWisFarEndPayloadDefect(0),
|
||||
etherWisFarEndServerDefect(1)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the current status at the
|
||||
far end of the path using a bit map that can indicate
|
||||
multiple defects at once. The bit positions are
|
||||
assigned as follows:
|
||||
|
||||
etherWisFarEndPayloadDefect(0)
|
||||
A far end payload defect (i.e., far end
|
||||
PLM-P or LCD-P) is currently being signaled
|
||||
in G1 bits 5-7.
|
||||
|
||||
etherWisFarEndServerDefect(1)
|
||||
A far end server defect (i.e., far end
|
||||
LOP-P or AIS-P) is currently being signaled
|
||||
in G1 bits 5-7. Note: when this bit is set,
|
||||
sonetPathSTSRDI MUST be set in the corresponding
|
||||
instance of sonetPathCurrentStatus."
|
||||
REFERENCE
|
||||
"[IEEE 802.3 Std.], 30.8.1.1.25, aFarEndPathStatus."
|
||||
::= { etherWisFarEndPathCurrentEntry 1 }
|
||||
|
||||
--
|
||||
-- Conformance Statements
|
||||
--
|
||||
|
||||
etherWisGroups OBJECT IDENTIFIER ::= { etherWisConformance 1 }
|
||||
|
||||
etherWisCompliances OBJECT IDENTIFIER ::= { etherWisConformance 2 }
|
||||
|
||||
-- Object Groups
|
||||
|
||||
etherWisDeviceGroupBasic OBJECT-GROUP
|
||||
OBJECTS {
|
||||
etherWisDeviceTxTestPatternMode,
|
||||
etherWisDeviceRxTestPatternMode
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of objects that support test
|
||||
features required of all WIS devices."
|
||||
::= { etherWisGroups 1 }
|
||||
|
||||
etherWisDeviceGroupExtra OBJECT-GROUP
|
||||
OBJECTS {
|
||||
etherWisDeviceRxTestPatternErrors
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of objects that support
|
||||
optional WIS device test features."
|
||||
::= { etherWisGroups 2 }
|
||||
|
||||
etherWisSectionGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
etherWisSectionCurrentJ0Transmitted,
|
||||
etherWisSectionCurrentJ0Received
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of objects that provide
|
||||
required information about a WIS section."
|
||||
::= { etherWisGroups 3 }
|
||||
|
||||
etherWisPathGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
etherWisPathCurrentStatus,
|
||||
etherWisPathCurrentJ1Transmitted,
|
||||
etherWisPathCurrentJ1Received
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of objects that provide
|
||||
required information about a WIS path."
|
||||
::= { etherWisGroups 4 }
|
||||
|
||||
etherWisFarEndPathGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
etherWisFarEndPathCurrentStatus
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of objects that provide required
|
||||
information about the far end of a WIS path."
|
||||
::= { etherWisGroups 5 }
|
||||
|
||||
-- Compliance Statements
|
||||
|
||||
etherWisCompliance MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The compliance statement for interfaces that include
|
||||
the Ethernet WIS. Compliance with the following
|
||||
external compliance statements is prerequisite:
|
||||
|
||||
MIB Module Compliance Statement
|
||||
---------- --------------------
|
||||
IF-MIB ifCompliance3
|
||||
IF-INVERTED-STACK-MIB ifInvCompliance
|
||||
EtherLike-MIB dot3Compliance2
|
||||
MAU-MIB mauModIfCompl3"
|
||||
|
||||
MODULE -- this module
|
||||
MANDATORY-GROUPS {
|
||||
etherWisDeviceGroupBasic,
|
||||
etherWisSectionGroup,
|
||||
etherWisPathGroup,
|
||||
etherWisFarEndPathGroup
|
||||
}
|
||||
|
||||
OBJECT etherWisDeviceTxTestPatternMode
|
||||
SYNTAX INTEGER {
|
||||
none(1),
|
||||
squareWave(2),
|
||||
mixedFrequency(4)
|
||||
}
|
||||
DESCRIPTION
|
||||
"Support for values other than none(1),
|
||||
squareWave(2), and mixedFrequency(4)
|
||||
is not required."
|
||||
|
||||
OBJECT etherWisDeviceRxTestPatternMode
|
||||
SYNTAX INTEGER {
|
||||
none(1),
|
||||
mixedFrequency(4)
|
||||
}
|
||||
DESCRIPTION
|
||||
"Support for values other than none(1)
|
||||
and mixedFrequency(4) is not required."
|
||||
|
||||
GROUP etherWisDeviceGroupExtra
|
||||
DESCRIPTION
|
||||
"Implementation of this group, along with support for
|
||||
the value prbs31(3) for etherWisDeviceTxTestPatternMode
|
||||
and etherWisDeviceRxTestPatternMode, is necessary if the
|
||||
optional PRBS31 test pattern mode is to be supported."
|
||||
|
||||
OBJECT etherWisDeviceRxTestPatternErrors
|
||||
WRITE-SYNTAX Gauge32 ( 0 )
|
||||
DESCRIPTION
|
||||
"An implementation is not required to
|
||||
allow values other than zero to be
|
||||
written to this object."
|
||||
|
||||
MODULE SONET-MIB
|
||||
MANDATORY-GROUPS {
|
||||
sonetMediumStuff2,
|
||||
sonetSectionStuff2,
|
||||
sonetLineStuff2,
|
||||
sonetFarEndLineStuff2,
|
||||
sonetPathStuff2,
|
||||
sonetFarEndPathStuff2
|
||||
}
|
||||
|
||||
OBJECT sonetMediumType
|
||||
SYNTAX INTEGER {
|
||||
sonet(1)
|
||||
}
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required, nor is support
|
||||
for any value other than sonet(1)."
|
||||
|
||||
OBJECT sonetMediumLineCoding
|
||||
SYNTAX INTEGER {
|
||||
sonetMediumNRZ(4)
|
||||
}
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required, nor is support
|
||||
for any value other than sonetMediumNRZ(4)."
|
||||
|
||||
OBJECT sonetMediumLineType
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT sonetMediumCircuitIdentifier
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT sonetMediumLoopbackConfig
|
||||
SYNTAX BITS {
|
||||
sonetNoLoop(0),
|
||||
sonetFacilityLoop(1)
|
||||
}
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required, nor is support for values
|
||||
other than sonetNoLoop(0) and sonetFacilityLoop(1)."
|
||||
|
||||
OBJECT sonetSESthresholdSet
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required, and only one
|
||||
of the enumerated values need be supported."
|
||||
|
||||
OBJECT sonetPathCurrentWidth
|
||||
SYNTAX INTEGER {
|
||||
sts192cSTM64(6)
|
||||
}
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required, nor is support
|
||||
for any value other than sts192cSTM64(6)."
|
||||
|
||||
::= { etherWisCompliances 1 }
|
||||
|
||||
END
|