Initial commit
This commit is contained in:
185
MIBS/junos/JUNIPER-ALARM-MIB
Normal file
185
MIBS/junos/JUNIPER-ALARM-MIB
Normal file
@ -0,0 +1,185 @@
|
||||
--
|
||||
-- Juniper Enterprise Specific MIB: Alarm MIB
|
||||
--
|
||||
-- Copyright (c) 2001-2003, Juniper Networks, Inc.
|
||||
-- All rights reserved.
|
||||
--
|
||||
-- The contents of this document are subject to change without notice.
|
||||
--
|
||||
|
||||
JUNIPER-ALARM-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, OBJECT-TYPE, Gauge32
|
||||
FROM SNMPv2-SMI
|
||||
TimeStamp
|
||||
FROM SNMPv2-TC
|
||||
jnxMibs
|
||||
FROM JUNIPER-SMI;
|
||||
|
||||
jnxAlarms MODULE-IDENTITY
|
||||
LAST-UPDATED "200307182153Z" -- Fri Jul 18 21:53:46 2003 UTC
|
||||
ORGANIZATION "Juniper Networks, Inc."
|
||||
CONTACT-INFO
|
||||
" Juniper Technical Assistance Center
|
||||
Juniper Networks, Inc.
|
||||
1133 Innovation Way
|
||||
Sunnyvale, CA 94089
|
||||
E-mail: support@juniper.net"
|
||||
|
||||
DESCRIPTION
|
||||
"This is Juniper Networks' implementation of enterprise
|
||||
specific MIB for alarms from the router chassis box."
|
||||
::= { jnxMibs 4 }
|
||||
|
||||
|
||||
|
||||
|
||||
-- ::= { jnxAlarms 1 } This OID is obsolete.
|
||||
|
||||
|
||||
--
|
||||
-- Craft Alarms
|
||||
--
|
||||
|
||||
jnxCraftAlarms OBJECT IDENTIFIER ::= { jnxAlarms 2 }
|
||||
|
||||
|
||||
jnxAlarmRelayMode OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
other(1), -- other or unknown
|
||||
passOn(2), -- alarms being passed on
|
||||
cutOff(3) -- alarms being cut off
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The alarm relay mode of the craft interface
|
||||
panel for both yellow and red alarms.
|
||||
|
||||
Both yellow and red alarms could be cut off
|
||||
by a front panel Alarm Cutoff / Lamp Test
|
||||
(ACO/LT) button.
|
||||
|
||||
In the pass-on mode, the alarm relay will be
|
||||
activated to pass on the yellow or red alarms.
|
||||
In the cut-off mode, both yellow and red alarms
|
||||
will be cut off from the alarm relays which are
|
||||
normally connected to audible sirens or visual
|
||||
flashing devices."
|
||||
|
||||
|
||||
::= { jnxCraftAlarms 1 }
|
||||
|
||||
|
||||
jnxYellowAlarms OBJECT IDENTIFIER ::= { jnxCraftAlarms 2 }
|
||||
|
||||
jnxYellowAlarmState OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
other(1), -- alarm state is unknown
|
||||
off(2), -- alarm is off
|
||||
on(3) -- alarm is on
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The yellow alarm state on the craft interface
|
||||
panel.
|
||||
|
||||
The yellow alarm is on when there is some
|
||||
system warning such as maintenance alert or
|
||||
significant temperature increase.
|
||||
|
||||
This yellow alarm state could be turned off
|
||||
by the ACO/LT (Alarm Cut Off / Lamp Test) button
|
||||
on the front panel module."
|
||||
|
||||
|
||||
::= { jnxYellowAlarms 1 }
|
||||
|
||||
jnxYellowAlarmCount OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The number of currently active and non-silent
|
||||
yellow alarms.
|
||||
|
||||
This object is independent of the ACO/LT (Alarm
|
||||
Cut Off / Lamp Test) button."
|
||||
|
||||
|
||||
::= { jnxYellowAlarms 2 }
|
||||
|
||||
|
||||
jnxYellowAlarmLastChange OBJECT-TYPE
|
||||
SYNTAX TimeStamp
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The value of sysUpTime when the yellow alarm
|
||||
last changed - either from off to on or vice
|
||||
versa. Zero if unknown or never changed since
|
||||
the agent was up."
|
||||
|
||||
|
||||
::= { jnxYellowAlarms 3 }
|
||||
|
||||
|
||||
jnxRedAlarms OBJECT IDENTIFIER ::= { jnxCraftAlarms 3 }
|
||||
|
||||
jnxRedAlarmState OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
other(1), -- alarm state is unknown
|
||||
off(2), -- alarm is off
|
||||
on(3) -- alarm is on
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The red alarm indication on the craft interface
|
||||
panel.
|
||||
|
||||
The red alarm is on when there is some system
|
||||
failure or power supply failure or the system
|
||||
is experiencing a hardware malfunction or some
|
||||
threshold is being exceeded.
|
||||
|
||||
This red alarm state could be turned off by the
|
||||
ACO/LT (Alarm Cut Off / Lamp Test) button on the
|
||||
front panel module."
|
||||
|
||||
|
||||
::= { jnxRedAlarms 1 }
|
||||
|
||||
|
||||
jnxRedAlarmCount OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The number of currently active and non-silent
|
||||
red alarms.
|
||||
|
||||
This object is independent of the ACO/LT (Alarm
|
||||
Cut Off / Lamp Test) button."
|
||||
|
||||
|
||||
::= { jnxRedAlarms 2 }
|
||||
|
||||
|
||||
jnxRedAlarmLastChange OBJECT-TYPE
|
||||
SYNTAX TimeStamp
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The value of sysUpTime when the red alarm
|
||||
last changed - either from off to on or vice
|
||||
versa. Zero if unknown or never changed since
|
||||
the agent was up."
|
||||
|
||||
|
||||
::= { jnxRedAlarms 3 }
|
||||
|
||||
|
||||
END
|