Initial commit
This commit is contained in:
156
MIBS/junose/IF-INVERTED-STACK-MIB
Normal file
156
MIBS/junose/IF-INVERTED-STACK-MIB
Normal file
@ -0,0 +1,156 @@
|
||||
|
||||
IF-INVERTED-STACK-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
-- *****************************************************************************
|
||||
-- Copyright (C) The Internet Society (2000). All Rights Reserved.
|
||||
-- This version of this MIB module is part of RFC 2864; see the RFC itself for
|
||||
-- full legal notices.
|
||||
-- *****************************************************************************
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, OBJECT-TYPE, mib-2 FROM SNMPv2-SMI
|
||||
RowStatus FROM SNMPv2-TC
|
||||
MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
|
||||
ifStackGroup2,
|
||||
ifStackHigherLayer, ifStackLowerLayer FROM IF-MIB;
|
||||
|
||||
ifInvertedStackMIB MODULE-IDENTITY
|
||||
LAST-UPDATED "200006140000Z"
|
||||
ORGANIZATION "IETF Interfaces MIB Working Group"
|
||||
CONTACT-INFO
|
||||
" Keith McCloghrie
|
||||
Cisco Systems, Inc.
|
||||
170 West Tasman Drive
|
||||
San Jose, CA 95134-1706
|
||||
US
|
||||
|
||||
408-526-5260
|
||||
kzm@cisco.com"
|
||||
DESCRIPTION
|
||||
"The MIB module which provides the Inverted Stack Table for
|
||||
interface sub-layers."
|
||||
REVISION "200006140000Z"
|
||||
DESCRIPTION
|
||||
"Initial revision, published as RFC 2864"
|
||||
::= { mib-2 77 }
|
||||
|
||||
ifInvMIBObjects OBJECT IDENTIFIER ::= { ifInvertedStackMIB 1 }
|
||||
|
||||
--
|
||||
-- The Inverted Interface Stack Group
|
||||
--
|
||||
|
||||
ifInvStackTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF IfInvStackEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A table containing information on the relationships between
|
||||
the multiple sub-layers of network interfaces. In
|
||||
particular, it contains information on which sub-layers run
|
||||
'underneath' which other sub-layers, where each sub-layer
|
||||
corresponds to a conceptual row in the ifTable. For
|
||||
example, when the sub-layer with ifIndex value x runs
|
||||
underneath the sub-layer with ifIndex value y, then this
|
||||
table contains:
|
||||
|
||||
ifInvStackStatus.x.y=active
|
||||
|
||||
For each ifIndex value, z, which identifies an active
|
||||
interface, there are always at least two instantiated rows
|
||||
in this table associated with z. For one of these rows, z
|
||||
is the value of ifStackHigherLayer; for the other, z is the
|
||||
value of ifStackLowerLayer. (If z is not involved in
|
||||
multiplexing, then these are the only two rows associated
|
||||
with z.)
|
||||
|
||||
For example, two rows exist even for an interface which has
|
||||
no others stacked on top or below it:
|
||||
|
||||
ifInvStackStatus.z.0=active
|
||||
ifInvStackStatus.0.z=active
|
||||
|
||||
This table contains exactly the same number of rows as the
|
||||
ifStackTable, but the rows appear in a different order."
|
||||
REFERENCE
|
||||
"ifStackTable of RFC 2863"
|
||||
::= { ifInvMIBObjects 1 }
|
||||
|
||||
ifInvStackEntry OBJECT-TYPE
|
||||
SYNTAX IfInvStackEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Information on a particular relationship between two sub-
|
||||
layers, specifying that one sub-layer runs underneath the
|
||||
other sub-layer. Each sub-layer corresponds to a conceptual
|
||||
row in the ifTable."
|
||||
INDEX { ifStackLowerLayer, ifStackHigherLayer }
|
||||
::= { ifInvStackTable 1 }
|
||||
|
||||
IfInvStackEntry ::=
|
||||
SEQUENCE {
|
||||
ifInvStackStatus RowStatus
|
||||
}
|
||||
|
||||
ifInvStackStatus OBJECT-TYPE
|
||||
SYNTAX RowStatus
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The status of the relationship between two sub-layers.
|
||||
|
||||
An instance of this object exists for each instance of the
|
||||
ifStackStatus object, and vice versa. For example, if the
|
||||
variable ifStackStatus.H.L exists, then the variable
|
||||
ifInvStackStatus.L.H must also exist, and vice versa. In
|
||||
addition, the two variables always have the same value.
|
||||
|
||||
However, unlike ifStackStatus, the ifInvStackStatus object
|
||||
is NOT write-able. A network management application wishing
|
||||
to change a relationship between sub-layers H and L cannot
|
||||
do so by modifying the value of ifInvStackStatus.L.H, but
|
||||
must instead modify the value of ifStackStatus.H.L. After
|
||||
the ifStackTable is modified, the change will be reflected
|
||||
in this table."
|
||||
::= { ifInvStackEntry 1 }
|
||||
|
||||
-- conformance information
|
||||
|
||||
ifInvConformance OBJECT IDENTIFIER ::= { ifInvMIBObjects 2 }
|
||||
|
||||
ifInvGroups OBJECT IDENTIFIER ::= { ifInvConformance 1 }
|
||||
ifInvCompliances OBJECT IDENTIFIER ::= { ifInvConformance 2 }
|
||||
|
||||
-- compliance statements
|
||||
|
||||
ifInvCompliance MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The compliance statement for SNMP entities which provide
|
||||
inverted information on the layering of network interfaces."
|
||||
|
||||
MODULE -- this module
|
||||
MANDATORY-GROUPS { ifInvStackGroup }
|
||||
|
||||
OBJECT ifInvStackStatus
|
||||
SYNTAX INTEGER { active(1) }
|
||||
DESCRIPTION
|
||||
"Support is only required for 'active'."
|
||||
|
||||
MODULE IF-MIB
|
||||
MANDATORY-GROUPS { ifStackGroup2 }
|
||||
|
||||
::= { ifInvCompliances 1 }
|
||||
|
||||
-- units of conformance
|
||||
|
||||
ifInvStackGroup OBJECT-GROUP
|
||||
OBJECTS { ifInvStackStatus }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of objects providing inverted information on
|
||||
the layering of MIB-II interfaces."
|
||||
::= { ifInvGroups 1 }
|
||||
|
||||
END
|