@ -0,0 +1,328 @@
|
||||
|
||||
-- *****************************************************************************
|
||||
-- Juniper-AUTOCONFIGURE-MIB
|
||||
--
|
||||
-- Juniper Networks Enterprise MIB
|
||||
-- Auto-Configuration MIB
|
||||
--
|
||||
-- Copyright (c) 2000 Unisphere Networks, Inc.
|
||||
-- Copyright (c) 2002 Juniper Networks, Inc.
|
||||
-- All Rights Reserved.
|
||||
-- *****************************************************************************
|
||||
|
||||
Juniper-AUTOCONFIGURE-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, OBJECT-TYPE, Integer32
|
||||
FROM SNMPv2-SMI
|
||||
TEXTUAL-CONVENTION, TruthValue
|
||||
FROM SNMPv2-TC
|
||||
MODULE-COMPLIANCE, OBJECT-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
InterfaceIndex
|
||||
FROM IF-MIB
|
||||
juniMibs
|
||||
FROM Juniper-MIBs
|
||||
JuniEnable
|
||||
FROM Juniper-TC;
|
||||
|
||||
juniAutoConfMIB MODULE-IDENTITY
|
||||
LAST-UPDATED "200407261954Z" -- 26-Jul-04 03:54 PM EDT
|
||||
ORGANIZATION "Juniper Networks"
|
||||
CONTACT-INFO
|
||||
" Juniper Networks, Inc.
|
||||
Postal: 10 Technology Park Drive
|
||||
Westford MA 01886-3146
|
||||
USA
|
||||
Tel: +1 978 589 5800
|
||||
Email: mib@Juniper.net"
|
||||
DESCRIPTION
|
||||
"The Auto-Configuration MIB for the Juniper Networks enterprise."
|
||||
-- Revision History
|
||||
REVISION "200407261954Z" -- 26-Jul-04 03:54 PM EDT - JUNOSe 7.0
|
||||
DESCRIPTION
|
||||
"Added Encapsulation Type Lockout objects."
|
||||
REVISION "200211221608Z" -- 22-Nov-02 11:08 AM EST - JUNOSe 5.0
|
||||
DESCRIPTION
|
||||
"Replaced Unisphere names with Juniper names."
|
||||
REVISION "200211221524Z" -- 22-Nov-02 10:24 AM EST - JUNOSe 4.0
|
||||
DESCRIPTION
|
||||
"Added bridgedEthernet(19) to JuniAutoConfEncaps."
|
||||
REVISION "200011160000Z" -- 16-Nov-00 - JUNOSe 3.0
|
||||
DESCRIPTION
|
||||
"Initial version of this MIB module."
|
||||
::= { juniMibs 48 }
|
||||
|
||||
|
||||
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
||||
-- Textual conventions
|
||||
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
||||
JuniAutoConfEncaps ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Encapsulated protocol type."
|
||||
SYNTAX INTEGER {
|
||||
ip(0),
|
||||
ppp(1),
|
||||
pppoe(17),
|
||||
bridgedEthernet(19) }
|
||||
|
||||
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
||||
-- Managed object groups
|
||||
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
||||
juniAutoConfObjects OBJECT IDENTIFIER ::= {juniAutoConfMIB 1}
|
||||
|
||||
--
|
||||
-- Functional groups
|
||||
--
|
||||
juniAutoConf OBJECT IDENTIFIER ::= {juniAutoConfObjects 1}
|
||||
|
||||
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
||||
-- Managed objects
|
||||
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
||||
--
|
||||
-- Enable/disable autoconfiguration for incoming data encapsulations.
|
||||
--
|
||||
juniAutoConfTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF JuniAutoConfEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Configures recognition of incoming data encapsulation types that
|
||||
trigger autoconfiguration on an interface. Also, configures the
|
||||
time range that the encapsulation type will be locked-out from
|
||||
recognition in the event of an error in creating an interface of
|
||||
the encapsulation type."
|
||||
::= { juniAutoConf 1 }
|
||||
|
||||
juniAutoConfEntry OBJECT-TYPE
|
||||
SYNTAX JuniAutoConfEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Configures recognition of an incoming data encapsulation type that
|
||||
triggers autoconfiguration on an interface. Also, configures the
|
||||
time range that the encapsulation type will be locked-out from
|
||||
recognition in the event of an error in creating an interface of
|
||||
the encapsulation type."
|
||||
INDEX { juniAutoConfIfIndex,
|
||||
juniAutoConfEncaps }
|
||||
::= { juniAutoConfTable 1 }
|
||||
|
||||
JuniAutoConfEntry ::= SEQUENCE {
|
||||
juniAutoConfIfIndex InterfaceIndex,
|
||||
juniAutoConfEncaps JuniAutoConfEncaps,
|
||||
juniAutoConfEnable JuniEnable,
|
||||
juniAutoConfLockoutSupported TruthValue,
|
||||
juniAutoConfLockoutMin Integer32,
|
||||
juniAutoConfLockoutMax Integer32,
|
||||
juniAutoConfLockoutTime Integer32,
|
||||
juniAutoConfLockoutElapsedTime Integer32,
|
||||
juniAutoConfNextLockoutTime Integer32 }
|
||||
|
||||
juniAutoConfIfIndex OBJECT-TYPE
|
||||
SYNTAX InterfaceIndex
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The ifIndex of the interface to which the autoconfiguration information
|
||||
in this entry applies."
|
||||
::= { juniAutoConfEntry 1 }
|
||||
|
||||
juniAutoConfEncaps OBJECT-TYPE
|
||||
SYNTAX JuniAutoConfEncaps
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The encapsulated protocol type to which the autoconfiguration
|
||||
information in this entry applies."
|
||||
::= { juniAutoConfEntry 2 }
|
||||
|
||||
juniAutoConfEnable OBJECT-TYPE
|
||||
SYNTAX JuniEnable
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"When enabled, permits autoconfiguration of the specified interface when
|
||||
the specified encapsulation is recognized in an incoming data frame."
|
||||
::= { juniAutoConfEntry 3 }
|
||||
|
||||
juniAutoConfLockoutSupported OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates whether lockout is supported for the specified
|
||||
encapsulation type for the specified interface. If lockout is
|
||||
supported, then juniAutoConfLockoutMin, juniAutoConfLockoutMax,
|
||||
juniAutoConfLockoutTime, juniAutoConfLockoutElapsedTime, and
|
||||
juniAutoConfNextLockoutTime are valid and supported in this entry."
|
||||
::= { juniAutoConfEntry 4 }
|
||||
|
||||
juniAutoConfLockoutMin OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..86400)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The lower bound, in seconds, of the time range used to specify
|
||||
the duration of the lockout of the encapsulation type from
|
||||
recognition for the specified interface. This only takes effect
|
||||
if juniAutoConfEnable is set to enable for the encapsulation type
|
||||
for this interface.
|
||||
The ability to lockout the specified encapsulation type from
|
||||
recognition in the event of an error in creating an interface of
|
||||
the encapsulation type is enabled by default. The initial lockout
|
||||
duration is this object's value and increases exponentially for
|
||||
each failure that occurs for the specified encapsulation type
|
||||
for the specified interface within the greater of 15 minutes
|
||||
and juniAutoConfLockoutMax. The lockout duration for the specified
|
||||
encapsulation type will not exceed juniAutoConfLockoutMax. If the
|
||||
time between creation errors for the specified encapsulation type
|
||||
for the specified interface is greater than the greater of 15
|
||||
minutes and juniAutoConfigLockoutMax, then the lockout duration
|
||||
reverts to this object's value.
|
||||
To disable the ability to lockout the specified encapsulation type
|
||||
from recognition in the event of an error in creating an interface
|
||||
of the encapsulation type for the specified interface, the value of
|
||||
this object and juniAutoConfLockoutMax must be set to 0. It is not
|
||||
recommended that this lockout feature be disabled except for
|
||||
debugging purposes."
|
||||
DEFVAL { 1 }
|
||||
::= { juniAutoConfEntry 5 }
|
||||
|
||||
juniAutoConfLockoutMax OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..86400)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The upper bound, in seconds, of the time range used to specify
|
||||
the duration of the lockout of the encapsulation type from
|
||||
recognition for the specified interface. This value must equal
|
||||
or exceed the value for juniAutoConfLockoutMin. This only takes
|
||||
effect if juniAutoConfEnable is set to enable for the encapsulation
|
||||
type for this interface.
|
||||
The ability to lockout the specified encapsulation type from
|
||||
recognition in the event of an error in creating an interface of
|
||||
the encapsulation type is enabled by default. The initial lockout
|
||||
duration is juniAutoConfLockoutMin and increases exponentially for
|
||||
each failure that occurs for the specified encapsulation type
|
||||
for the specified interface within the greater of 15 minutes
|
||||
and this object's value. The lockout duration for the specified
|
||||
encapsulation type will not exceed this object's value. If the
|
||||
time between creation errors for the specified encapsulation type
|
||||
for the specified interface is greater than the greater of 15
|
||||
minutes and this object's value, then the lockout duration
|
||||
reverts to juniAutoConfigLockoutMin.
|
||||
To disable the ability to lockout the specified encapsulation type
|
||||
from recognition in the event of an error in creating an interface
|
||||
of the encapsulation type for the specified interface, the value of
|
||||
this object and juniAutoConfLockoutMin must be set to 0. It is not
|
||||
recommended that this lockout feature be disabled except for
|
||||
debugging purposes."
|
||||
DEFVAL { 300 }
|
||||
::= { juniAutoConfEntry 6 }
|
||||
|
||||
juniAutoConfLockoutTime OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..86400)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The time duration, in seconds, currently used to lockout the
|
||||
specified encapsulation type from recognition for the specified
|
||||
interface. The reported value is within the range specified by
|
||||
juniAutoConfLockoutMin and juniAutoConfLockoutMax. A value of 0
|
||||
indicates that no lockout is occurring for the encapsulation type
|
||||
for the specified interface."
|
||||
::= { juniAutoConfEntry 7 }
|
||||
|
||||
juniAutoConfLockoutElapsedTime OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..86400)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The elapsed time, in seconds, that the specified encapsulation type
|
||||
has been locked-out from recognition for the specified interface.
|
||||
Its value will not exceed that of juniAutoConfLockoutTime. A value of
|
||||
0 indicates that no lockout is occurring for the encapsulation type
|
||||
for the specified interface."
|
||||
::= { juniAutoConfEntry 8 }
|
||||
|
||||
juniAutoConfNextLockoutTime OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..86400)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The time duration, in seconds, that will be used to lockout the
|
||||
specified encapsulation type from recognition for the specified
|
||||
interface for the next event that results in a lockout condition.
|
||||
The reported value is within the range specified by
|
||||
juniAutoConfLockoutMin and juniAutoConfLockoutMax. When
|
||||
juniAutoConfEnable is set to enable, a value of 0 indicates that
|
||||
lockout is prevented from occurring for the encapsulation type
|
||||
for the specified interface (i.e., juniAutoConfLockoutMin and
|
||||
juniAutoConfLockoutMax are both set to 0)."
|
||||
::= { juniAutoConfEntry 9 }
|
||||
|
||||
|
||||
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
||||
-- Conformance information
|
||||
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
||||
juniAutoConfMIBConformance
|
||||
OBJECT IDENTIFIER ::= { juniAutoConfMIB 4 }
|
||||
juniAutoConfMIBCompliances
|
||||
OBJECT IDENTIFIER ::= { juniAutoConfMIBConformance 1 }
|
||||
juniAutoConfMIBGroups
|
||||
OBJECT IDENTIFIER ::= { juniAutoConfMIBConformance 2 }
|
||||
|
||||
--
|
||||
-- compliance statements
|
||||
--
|
||||
juniAutoConfCompliance MODULE-COMPLIANCE
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"Obsolete compliance statement for systems supporting enabling of
|
||||
autoconfiguration operation. This statement was obsoleted when
|
||||
encapsulation type lockout objects were added."
|
||||
MODULE -- this module
|
||||
MANDATORY-GROUPS {
|
||||
juniAutoConfGroup }
|
||||
::= { juniAutoConfMIBCompliances 1 }
|
||||
|
||||
juniAutoConfCompliance2 MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The compliance statement for systems supporting enabling of
|
||||
autoconfiguration operation."
|
||||
MODULE -- this module
|
||||
MANDATORY-GROUPS {
|
||||
juniAutoConfGroup2 }
|
||||
::= { juniAutoConfMIBCompliances 2 }
|
||||
|
||||
--
|
||||
-- units of conformance
|
||||
--
|
||||
juniAutoConfGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
juniAutoConfEnable }
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"Obsoleted collection of objects providing management of
|
||||
autoconfiguration enabling in a Juniper product. This group
|
||||
became obsolete when Encapsulation Type Lockout support was added."
|
||||
::= { juniAutoConfMIBGroups 1 } -- JUNOSe 3.0
|
||||
|
||||
juniAutoConfGroup2 OBJECT-GROUP
|
||||
OBJECTS {
|
||||
juniAutoConfLockoutSupported,
|
||||
juniAutoConfLockoutMin,
|
||||
juniAutoConfLockoutMax,
|
||||
juniAutoConfLockoutTime,
|
||||
juniAutoConfLockoutElapsedTime,
|
||||
juniAutoConfNextLockoutTime }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The basic collection of objects providing management of
|
||||
autoconfiguration enabling in a Juniper product."
|
||||
::= { juniAutoConfMIBGroups 2 } -- JUNOSe 7.0
|
||||
|
||||
END
|