Initial commit
This commit is contained in:
74
MIBS/linksys/LINKSYS-BaudRate-MIB
Normal file
74
MIBS/linksys/LINKSYS-BaudRate-MIB
Normal file
@ -0,0 +1,74 @@
|
||||
LINKSYS-BaudRate-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
-- Title: LINKSYS LOCALIZATION ROS
|
||||
-- This Private MIB supports the baudrate of the local terminal of ROS products
|
||||
-- Version: 7.39
|
||||
-- Date: 14 Apr 2005
|
||||
|
||||
|
||||
|
||||
IMPORTS
|
||||
rnd FROM LINKSYS-MIB
|
||||
OBJECT-TYPE,
|
||||
MODULE-IDENTITY FROM SNMPv2-SMI;
|
||||
|
||||
rlRs232 MODULE-IDENTITY
|
||||
LAST-UPDATED "200504140000Z"
|
||||
ORGANIZATION "Linksys LLC."
|
||||
CONTACT-INFO
|
||||
"www.linksys.com/business/support"
|
||||
DESCRIPTION
|
||||
"The private MIB module definition for baudrate."
|
||||
REVISION "200504140000Z"
|
||||
DESCRIPTION
|
||||
"Initial revision."
|
||||
::= { rnd 104 }
|
||||
|
||||
rlRs232MibVersion OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"MIB's version, the current version is 1."
|
||||
::= { rlRs232 1 }
|
||||
|
||||
rlRs232AutoBaudRateStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
enable(1),
|
||||
disable(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Show the current Auto BaudRate status"
|
||||
::= { rlRs232 2 }
|
||||
|
||||
rlRs232AutoBaudRateStatusAfterReset OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
enable(1),
|
||||
disable(2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Show/Set the Auto BaudRate status after reset"
|
||||
::= { rlRs232 3 }
|
||||
|
||||
rlRs232BaudRate OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
baud2400(1),
|
||||
baud4800(2),
|
||||
baud9600(3),
|
||||
baud19200(4),
|
||||
baud38400(5),
|
||||
baud57600(6),
|
||||
baud115200(7)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Show/Set the current Baud Rate status"
|
||||
::= { rlRs232 4 }
|
||||
|
||||
END
|
||||
|