LINKSYS-POE-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
-- Title: Linksys LOCALIZATION ROS
|
||||
-- This Private MIB is enhancement for rfc3621.txt - Power Ethernet Mib
|
||||
-- Version: 7.50
|
||||
-- Date: 28 Nov 2005
|
||||
|
||||
IMPORTS
|
||||
rnd FROM LINKSYS-MIB
|
||||
DisplayString, TruthValue FROM SNMPv2-TC
|
||||
OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI;
|
||||
|
||||
|
||||
rlPoe MODULE-IDENTITY
|
||||
LAST-UPDATED "200911260000Z"
|
||||
ORGANIZATION "Linksys."
|
||||
CONTACT-INFO
|
||||
"Linksys.com"
|
||||
DESCRIPTION
|
||||
"Add a new field in the PoE MIB to indicate Max power allocation allowed"
|
||||
REVISION "201006020000Z"
|
||||
DESCRIPTION
|
||||
"The private MIB module definition for Power Over Ethernet."
|
||||
REVISION "200911260000Z"
|
||||
DESCRIPTION
|
||||
"Initial revision."
|
||||
::= { rnd 108 }
|
||||
|
||||
rlPethPsePortTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlPethPsePortEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" The table listing additional information for Power Over Ethernet ports."
|
||||
::= {rlPoe 1 }
|
||||
|
||||
rlPethPsePortEntry OBJECT-TYPE
|
||||
SYNTAX RlPethPsePortEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" An entry in the rlPethPsePortTable."
|
||||
INDEX { rlPethPsePortGroupIndex , rlPethPsePortIndex }
|
||||
::= {rlPethPsePortTable 1 }
|
||||
|
||||
RlPethPsePortEntry ::= SEQUENCE {
|
||||
rlPethPsePortGroupIndex INTEGER,
|
||||
rlPethPsePortIndex INTEGER,
|
||||
rlPethPsePortOutputVoltage INTEGER,
|
||||
rlPethPsePortOutputCurrent INTEGER,
|
||||
rlPethPsePortOutputPower INTEGER,
|
||||
rlPethPsePortPowerLimit INTEGER,
|
||||
rlPethPsePortStatus INTEGER,
|
||||
rlPethPsePortStatusDescription DisplayString,
|
||||
rlPethPsePortOperPowerLimit INTEGER,
|
||||
rlPethPsePortSupportPoePlus TruthValue,
|
||||
rlPethPsePortTimeRangeName DisplayString,
|
||||
rlPethPsePortOperStatus TruthValue,
|
||||
rlPethPsePortMaxPowerAllocAllowed INTEGER,
|
||||
rlPethPsePortSupportPoe TruthValue
|
||||
}
|
||||
|
||||
rlPethPsePortGroupIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER (1..2147483647)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable uniquely identifies the group
|
||||
containing the port to which a power Ethernet PSE is
|
||||
connected. Group means box in the stack, module in a
|
||||
rack and the value 1 MUST be used for non-modular devices.
|
||||
Furthermore, the same value MUST be used in this variable,
|
||||
pethMainPseGroupIndex, and pethNotificationControlGroupIndex
|
||||
to refer to a given box in a stack or module in the rack."
|
||||
::= { rlPethPsePortEntry 1 }
|
||||
|
||||
rlPethPsePortIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER (1..2147483647)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable uniquely identifies the power Ethernet PSE
|
||||
port within group pethPsePortGroupIndex to which the
|
||||
power Ethernet PSE entry is connected."
|
||||
::= { rlPethPsePortEntry 2 }
|
||||
|
||||
rlPethPsePortOutputVoltage OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates on the output voltage level in milli volts from rlPethPsePortIndex."
|
||||
::= { rlPethPsePortEntry 3 }
|
||||
|
||||
rlPethPsePortOutputCurrent OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates on the output current level in milli amper from rlPethPsePortIndex."
|
||||
::= { rlPethPsePortEntry 4 }
|
||||
|
||||
rlPethPsePortOutputPower OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates on the output power level in milli watts from rlPethPsePortIndex."
|
||||
::= { rlPethPsePortEntry 5 }
|
||||
|
||||
rlPethPsePortPowerLimit OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..2147483647)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates on the user configured power level in milli watts which is available from rlPethPsePortIndex."
|
||||
::= { rlPethPsePortEntry 6 }
|
||||
|
||||
rlPethPsePortStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates on the hardware status of rlPethPsePortIndex."
|
||||
::= { rlPethPsePortEntry 7 }
|
||||
|
||||
rlPethPsePortStatusDescription OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..80))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the description of the hardware status of rlPethPsePortIndex."
|
||||
::= { rlPethPsePortEntry 8 }
|
||||
|
||||
rlPethPsePortOperPowerLimit OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the maximum power level in milli watts which is available from rlPethPsePortIndex."
|
||||
::= { rlPethPsePortEntry 9 }
|
||||
|
||||
rlPethPsePortSupportPoePlus OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates if the port supports poe plus."
|
||||
::= { rlPethPsePortEntry 10 }
|
||||
|
||||
rlPethPsePortTimeRangeName OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..32))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable is used to bind PoE port to time range."
|
||||
::= { rlPethPsePortEntry 11 }
|
||||
|
||||
rlPethPsePortOperStatus OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This Read-Only variable indicates PoE port current status affected by time range active/inactive and admin status."
|
||||
::= { rlPethPsePortEntry 12 }
|
||||
|
||||
rlPethPsePortMaxPowerAllocAllowed OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates the maximum power allocation allowed per port (including wire power loses) in milli-watts which is available from rlPethPsePortIndex."
|
||||
::= { rlPethPsePortEntry 13 }
|
||||
|
||||
rlPethPsePortSupportPoe OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable indicates if the port is a poe port"
|
||||
::= { rlPethPsePortEntry 14 }
|
||||
|
||||
rlPethMainPseTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlPethMainPseEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" The table listing additional read - only information for Power Over Ethernet."
|
||||
::= {rlPoe 2 }
|
||||
|
||||
rlPethMainPseEntry OBJECT-TYPE
|
||||
SYNTAX RlPethMainPseEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" An entry in the rlPethMainPseTable."
|
||||
INDEX { rlPethMainPseGroupIndex }
|
||||
::= {rlPethMainPseTable 1 }
|
||||
|
||||
RlPethMainPseEntry ::= SEQUENCE {
|
||||
rlPethMainPseGroupIndex INTEGER,
|
||||
rlPethMainPseSwVersion DisplayString,
|
||||
rlPethMainPseHwVersion DisplayString,
|
||||
rlPethMainPseHwType INTEGER,
|
||||
rlPethMainPsePowerGuardBand INTEGER
|
||||
|
||||
}
|
||||
|
||||
rlPethMainPseGroupIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER (1..2147483647)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable uniquely identifies the group
|
||||
containing the port to which a power Ethernet PSE is
|
||||
connected. Group means box in the stack, module in a
|
||||
rack and the value 1 MUST be used for non-modular devices.
|
||||
Furthermore, the same value MUST be used in this variable,
|
||||
pethMainPseGroupIndex, and pethNotificationControlGroupIndex
|
||||
to refer to a given box in a stack or module in the rack."
|
||||
::= { rlPethMainPseEntry 1 }
|
||||
|
||||
rlPethMainPseSwVersion OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..20))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable identifies the MCU SW version."
|
||||
::= { rlPethMainPseEntry 2 }
|
||||
|
||||
rlPethMainPseHwVersion OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..20))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable identifies the MCU HW version."
|
||||
::= { rlPethMainPseEntry 3 }
|
||||
|
||||
rlPethMainPseHwType OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
enhanced(1),
|
||||
plus(2),
|
||||
auto(3),
|
||||
nonPoe(4),
|
||||
enhancedPlus(5)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable identifies the MCU HW type (enhanced, plus, none)."
|
||||
::= { rlPethMainPseEntry 4 }
|
||||
|
||||
rlPethMainPsePowerGuardBand OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable identifies the guard band in [W] for not connecting
|
||||
additional ports."
|
||||
::= { rlPethMainPseEntry 5 }
|
||||
|
||||
rlPethPowerPseTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RlPethPowerPseEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" The table listing additional read-write information for Power Over Ethernet."
|
||||
::= {rlPoe 3 }
|
||||
|
||||
rlPethPowerPseEntry OBJECT-TYPE
|
||||
SYNTAX RlPethPowerPseEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" An entry in the rlPethPowerPseTable."
|
||||
INDEX { rlPethPowerPseGroupIndex }
|
||||
::= {rlPethPowerPseTable 1 }
|
||||
|
||||
RlPethPowerPseEntry ::= SEQUENCE {
|
||||
rlPethPowerPseGroupIndex INTEGER,
|
||||
rlPethPowerPsePower INTEGER,
|
||||
rlPethPowerPseRpsPower INTEGER,
|
||||
rlPethPowerPsePowerManagementMode INTEGER,
|
||||
rlPethPowerPsedisconnectMethod INTEGER,
|
||||
rlPethPowerPseTemperatureSensor INTEGER,
|
||||
rlPethPowerPseInrushTestEnabled INTEGER
|
||||
}
|
||||
|
||||
rlPethPowerPseGroupIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER (1..8)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable uniquely identifies the group
|
||||
containing the port to which a power Ethernet PSE is
|
||||
connected. Group means box in the stack, module in a
|
||||
rack and the value 1 MUST be used for non-modular devices.
|
||||
Furthermore, the same value MUST be used in this variable,
|
||||
PethPowerPseGroupIndex, and pethNotificationControlGroupIndex
|
||||
to refer to a given box in a stack or module in the rack."
|
||||
::= { rlPethPowerPseEntry 1 }
|
||||
|
||||
|
||||
-- depricated
|
||||
rlPethPowerPsePower OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
none(0),
|
||||
ps1(1),
|
||||
ps2(2),
|
||||
ps3(3)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable identifies the maximum power in [W] supplied by PSE."
|
||||
::= { rlPethPowerPseEntry 2 }
|
||||
|
||||
-- depricated
|
||||
rlPethPowerPseRpsPower OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
none(0),
|
||||
rps1(1),
|
||||
rps2(2),
|
||||
rps3(3)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable identifies the maximum power in [W] supplied by PSE + RPS."
|
||||
::= { rlPethPowerPseEntry 3 }
|
||||
|
||||
rlPethPowerPsePowerManagementMode OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
portlimit(0),
|
||||
classlimit(5),
|
||||
maxlimit(6)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable identifies power management mode."
|
||||
::= { rlPethPowerPseEntry 4 }
|
||||
|
||||
rlPethPowerPsedisconnectMethod OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
lowestpriority(0),
|
||||
nextport(1)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable identifies disconnect method. "
|
||||
::= { rlPethPowerPseEntry 5 }
|
||||
|
||||
rlPethPowerPseTemperatureSensor OBJECT-TYPE
|
||||
SYNTAX INTEGER (-200..200)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable identifies the pd temperature sensor. "
|
||||
::= { rlPethPowerPseEntry 6 }
|
||||
|
||||
rlPethPowerPseInrushTestEnabled OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
enabled(0),
|
||||
disabled(1)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This variable identifies if HW inrush test will be disabled.
|
||||
by default HW inrush test is enabled."
|
||||
::= { rlPethPowerPseEntry 7 }
|
||||
|
||||
END
|
||||
|