Initial commit
This commit is contained in:
602
MIBS/meinberg/MBG-SNMP-XPT-MIB
Executable file
602
MIBS/meinberg/MBG-SNMP-XPT-MIB
Executable file
@ -0,0 +1,602 @@
|
||||
MBG-SNMP-XPT-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
--
|
||||
-- Top-level infrastructure of the MBG -SNMP project enterprise MIB tree
|
||||
--
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, OBJECT-TYPE, Integer32, NOTIFICATION-TYPE FROM SNMPv2-SMI
|
||||
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF
|
||||
DisplayString FROM SNMPv2-TC
|
||||
|
||||
mbgSnmpRoot FROM MBG-SNMP-ROOT-MIB;
|
||||
|
||||
mbgXPT MODULE-IDENTITY
|
||||
LAST-UPDATED "201201250000Z"
|
||||
ORGANIZATION "www.meinberg.de"
|
||||
CONTACT-INFO
|
||||
"postal: Meinberg Funkuhren
|
||||
Auf der Landwehr 22
|
||||
31812 Bad Pyrmont
|
||||
Germany
|
||||
|
||||
email: info@meinberg.de"
|
||||
DESCRIPTION
|
||||
"Top-level infrastructure of the MBG-SNMP project enterprise MIB tree"
|
||||
REVISION "201201250000Z"
|
||||
DESCRIPTION
|
||||
"Update to new format referencing MBG-SNMP-ROOT-MIB"
|
||||
REVISION "200601200000Z"
|
||||
DESCRIPTION
|
||||
"Covering LAN-XPT and SCU-XPT modules from Meinberg"
|
||||
::= { mbgSnmpRoot 10 }
|
||||
|
||||
|
||||
--
|
||||
-- MBG-SNMP enterprise-specific management objects
|
||||
--
|
||||
--
|
||||
-- Copy everything from here into your MBG-SNMP-MIB.txt file, if you are using several different SNMP-supporting Meinberg systems
|
||||
--
|
||||
|
||||
mbgGPSRefclock1 OBJECT IDENTIFIER ::= {mbgXPT 2}
|
||||
mbgGPSRefclock2 OBJECT IDENTIFIER ::= {mbgXPT 3}
|
||||
mbgSCU OBJECT IDENTIFIER ::= {mbgXPT 4}
|
||||
mbgXPTTraps OBJECT IDENTIFIER ::= {mbgXPT 5}
|
||||
|
||||
|
||||
--
|
||||
-- GPS Refclock states
|
||||
-- (For SCUXPT systems this is Refclock 1)
|
||||
--
|
||||
|
||||
mbgGPSRefclock1Type OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Type of clock"
|
||||
::= { mbgGPSRefclock1 1 }
|
||||
|
||||
mbgGPSRefclock1TypeVal OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Type of refclock as value"
|
||||
--- " 0: not available"
|
||||
--- " 1: GPS167 1HE"
|
||||
--- " 2: GPS167 BGT/TGP"
|
||||
--- " 3: PZF509 1HE"
|
||||
--- " 4: PZF509 BGT/TGP"
|
||||
--- " 5: SHS 1HE"
|
||||
--- " 6: SHS BGT"
|
||||
--- " 7: SHS-FRC 1HE"
|
||||
--- " 8: SHS-FRC BGT"
|
||||
--- " 9: TCR509 1HE"
|
||||
--- "10: TCR509 BGT/TGP"
|
||||
--- "11: RD 1HE"
|
||||
--- "12: RD BGT/TGP"
|
||||
--- "13: EDT 1HE"
|
||||
--- "14: EDT BGT/TGP"
|
||||
--- "15: AHS"
|
||||
--- "16: DHS"
|
||||
DEFVAL { 0 }
|
||||
::= { mbgGPSRefclock1 2 }
|
||||
|
||||
mbgGPSRefclock1Mode OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current Mode of refclock"
|
||||
::= { mbgGPSRefclock1 3 }
|
||||
|
||||
mbgGPSRefclock1ModeVal OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current Mode of refclock as value"
|
||||
--- " 0: not available"
|
||||
--- " 1: Normal Operation"
|
||||
--- " 2: Tracking/Searching"
|
||||
--- " 3: Antenna Faulty"
|
||||
--- " 4: Warm Boot"
|
||||
--- " 5: Cold Boot"
|
||||
DEFVAL { 0 }
|
||||
::= { mbgGPSRefclock1 4 }
|
||||
|
||||
mbgGPSRef1GpsState OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current State of GPS refclock "
|
||||
::= { mbgGPSRefclock1 5 }
|
||||
|
||||
mbgGPSRef1GpsStateVal OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current State of GPS refclock as value"
|
||||
--- " 0: not available"
|
||||
--- " 1: synchronized"
|
||||
--- " 2: not synchronized"
|
||||
DEFVAL { 0 }
|
||||
::= { mbgGPSRefclock1 6 }
|
||||
|
||||
mbgGPSRef1GpsPosition OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current Position of GPS refclock "
|
||||
::= { mbgGPSRefclock1 7 }
|
||||
|
||||
mbgGPSRef1GpsSatellites OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current Satellites in view and good of GPS refclock "
|
||||
::= { mbgGPSRefclock1 8 }
|
||||
|
||||
mbgGPSRef1GpsSatellitesGood OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current good Satellites of GPS refclock as value"
|
||||
::= { mbgGPSRefclock1 9 }
|
||||
|
||||
mbgGPSRef1GpsSatellitesInView OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current satellites in view of GPS refclock as value"
|
||||
::= { mbgGPSRefclock1 10 }
|
||||
|
||||
|
||||
--
|
||||
-- GPS Refclock states
|
||||
-- (for SCUXPT 2nd refclock)
|
||||
|
||||
mbgGPSRefclock2Type OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Type of clock"
|
||||
::= { mbgGPSRefclock2 1 }
|
||||
|
||||
mbgGPSRefclock2TypeVal OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Type of refclock as value"
|
||||
--- " 0: not available"
|
||||
--- " 1: GPS167 1HE"
|
||||
--- " 2: GPS167 BGT/TGP"
|
||||
--- " 3: PZF509 1HE"
|
||||
--- " 4: PZF509 BGT/TGP"
|
||||
--- " 5: SHS 1HE"
|
||||
--- " 6: SHS BGT"
|
||||
--- " 7: SHS-FRC 1HE"
|
||||
--- " 8: SHS-FRC BGT"
|
||||
--- " 9: TCR509 1HE"
|
||||
--- "10: TCR509 BGT/TGP"
|
||||
--- "11: RD 1HE"
|
||||
--- "12: RD BGT/TGP"
|
||||
--- "13: EDT 1HE"
|
||||
--- "14: EDT BGT/TGP"
|
||||
--- "15: AHS"
|
||||
--- "16: DHS"
|
||||
DEFVAL { 0 }
|
||||
::= { mbgGPSRefclock2 2 }
|
||||
|
||||
mbgGPSRefclock2Mode OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current Mode of refclock"
|
||||
::= { mbgGPSRefclock2 3 }
|
||||
|
||||
mbgGPSRefclock2ModeVal OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current Mode of refclock as value"
|
||||
--- " 0: not available"
|
||||
--- " 1: Normal Operation"
|
||||
--- " 2: Tracking/Searching"
|
||||
--- " 3: Antenna Faulty"
|
||||
--- " 4: Warm Boot"
|
||||
--- " 5: Cold Boot"
|
||||
DEFVAL { 0 }
|
||||
::= { mbgGPSRefclock2 4 }
|
||||
|
||||
mbgGPSRef2GpsState OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current State of GPS refclock "
|
||||
::= { mbgGPSRefclock2 5 }
|
||||
|
||||
mbgGPSRef2GpsStateVal OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current State of GPS refclock as value"
|
||||
--- " 0: not available"
|
||||
--- " 1: synchronized"
|
||||
--- " 2: not synchronized"
|
||||
DEFVAL { 0 }
|
||||
::= { mbgGPSRefclock2 6 }
|
||||
|
||||
mbgGPSRef2GpsPosition OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current Position of GPS refclock "
|
||||
::= { mbgGPSRefclock2 7 }
|
||||
|
||||
mbgGPSRef2GpsSatellites OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current Satellites in view and good of GPS refclock "
|
||||
::= { mbgGPSRefclock2 8 }
|
||||
|
||||
mbgGPSRef2GpsSatellitesGood OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current good Satellites of GPS refclock as value"
|
||||
::= { mbgGPSRefclock2 9 }
|
||||
|
||||
mbgGPSRef2GpsSatellitesInView OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current satellites in view of GPS refclock as value"
|
||||
::= { mbgGPSRefclock2 10 }
|
||||
|
||||
|
||||
|
||||
--
|
||||
-- GPS Switchcard states
|
||||
-- (for SCUXPT)
|
||||
|
||||
mbgSCUType OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Type of clock"
|
||||
::= { mbgSCU 1 }
|
||||
|
||||
mbgSCUTypeVal OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Type of Switchcard as value"
|
||||
DEFVAL { 0 }
|
||||
::= { mbgSCU 2 }
|
||||
|
||||
mbgSCUMaster OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current selected masterclock of switchcard"
|
||||
::= { mbgSCU 3 }
|
||||
|
||||
mbgSCUMasterVal OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current selected masterclock of switchcard as value"
|
||||
--- " 0: no master selected (outputs disabled)"
|
||||
--- " 1: GPS clock 1 is master"
|
||||
--- " 2: GPS clock 2 is master"
|
||||
DEFVAL { 0 }
|
||||
::= { mbgSCU 4 }
|
||||
|
||||
mbgSCUMasterselect OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current masterselect mode of GPS Switchcard "
|
||||
::= { mbgSCU 5 }
|
||||
|
||||
mbgSCUMasterselectVal OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current masterselect mode of GPS switchcard as value"
|
||||
--- " 0: local masterselect"
|
||||
--- " 1: remote masterselect"
|
||||
DEFVAL { 0 }
|
||||
::= { mbgSCU 6 }
|
||||
|
||||
mbgSCUTimeSync1 OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current time sync status of clock 1"
|
||||
::= { mbgSCU 7 }
|
||||
|
||||
mbgSCUTimeSync2 OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current time sync status of clock 2"
|
||||
::= { mbgSCU 8 }
|
||||
|
||||
mbgSCUTimelimitError OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current state of time limit alarm (not used)"
|
||||
::= { mbgSCU 9 }
|
||||
|
||||
mbgSCUDisableOutputs OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current state of outputs (0=outputs disabled, 1=outputs enabled)"
|
||||
::= { mbgSCU 10 }
|
||||
|
||||
mbgSCUSelectedInput OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current selected clock for status queries as a string"
|
||||
::= { mbgSCU 11 }
|
||||
|
||||
mbgSCUSelectedInputVal OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current selected clock for status queries as an integer"
|
||||
--- " 0: no clock selected"
|
||||
--- " 1: GPS clock 1 is selected"
|
||||
--- " 2: GPS clock 2 is selected"
|
||||
::= { mbgSCU 12 }
|
||||
|
||||
mbgSCUACOMode OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current state of ACO (access control override)"
|
||||
--- " 0: ACO mode off (no firmware updates, password protection and encryption on)"
|
||||
--- " 1: ACO mode on (firmware updates possible, password set to empty string (=just press enter)"
|
||||
::= { mbgSCU 13 }
|
||||
|
||||
mbgSCUPSUStatus OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current status of power supply units as a string"
|
||||
::= { mbgSCU 14 }
|
||||
|
||||
mbgSCUPSU1Status OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current status of power supply unit 1"
|
||||
--- " 0: failure / not available"
|
||||
--- " 1: OK / in operation"
|
||||
::= { mbgSCU 15 }
|
||||
|
||||
mbgSCUPSU2Status OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"current status of power supply unit 2"
|
||||
--- " 0: failure / not available"
|
||||
--- " 1: OK / in operation"
|
||||
::= { mbgSCU 16 }
|
||||
|
||||
|
||||
|
||||
|
||||
--
|
||||
-- SNMP trap definitions
|
||||
--
|
||||
|
||||
mbgGPSTrapColdBoot NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"trap to be sent when Refclock is in Cold Boot mode"
|
||||
::= { mbgXPTTraps 1 }
|
||||
|
||||
mbgGPSTrapWarmBoot NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"trap to be sent when Refclock is in Warm Boot mode"
|
||||
::= { mbgXPTTraps 2 }
|
||||
|
||||
mbgGPSNavSolved NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"trap to be sent when Refclock calculated its actual position"
|
||||
::= { mbgXPTTraps 3 }
|
||||
|
||||
mbgGPSTrapReceiverNotResponding NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"trap to be sent when GPS receiver is not responding "
|
||||
::= { mbgXPTTraps 4 }
|
||||
|
||||
mbgGPSTrapReceiverNotSync NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"trap to be sent when GPS receiver is not synchronised "
|
||||
::= { mbgXPTTraps 5 }
|
||||
|
||||
mbgGPSTrapAntennaFaulty NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"trap to be sent when connection to antenna is broken "
|
||||
::= { mbgXPTTraps 6 }
|
||||
|
||||
mbgGPSTrapAntennaReconnect NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"trap to be sent when antenna has been reconnected "
|
||||
::= { mbgXPTTraps 7 }
|
||||
|
||||
mbgGPSTrapLANXPTBoot NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"trap to be sent when LANXPT has been rebooted"
|
||||
::= { mbgXPTTraps 8 }
|
||||
|
||||
mbgGPSTrapLeapSecondAnnounced NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"trap to be sent when a leap second has been announced "
|
||||
::= { mbgXPTTraps 9 }
|
||||
|
||||
mbgGPSTrapMasterclockSwitchover NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"trap to be sent when masterclock changes "
|
||||
::= { mbgXPTTraps 10 }
|
||||
|
||||
mbgGPSTrapPowerSupplyFailure NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"trap to be sent when a power supply unit fails"
|
||||
::= { mbgXPTTraps 11 }
|
||||
|
||||
mbgGPSTrapPowerSupplyOK NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"trap to be sent when a power supply unit restores operation"
|
||||
::= { mbgXPTTraps 12 }
|
||||
|
||||
mbgGPSTrapTestNotification NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"trap to be sent when a test notification has been requested "
|
||||
::= { mbgXPTTraps 99 }
|
||||
|
||||
|
||||
--
|
||||
-- Conformance Statements
|
||||
--
|
||||
|
||||
|
||||
mbgXPTConformance OBJECT IDENTIFIER ::= { mbgXPT 90 }
|
||||
mbgXPTCompliances OBJECT IDENTIFIER ::= { mbgXPTConformance 1 }
|
||||
mbgXPTGroups OBJECT IDENTIFIER ::= { mbgXPTConformance 2 }
|
||||
|
||||
mbgXPTCompliance MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The compliance statement for SNMP entities which implement version 2
|
||||
of the XPT MIB"
|
||||
MODULE -- this module
|
||||
MANDATORY-GROUPS {
|
||||
mbgXPTObjectsGroup,
|
||||
mbgXPTTrapsGroup
|
||||
}
|
||||
::= { mbgXPTCompliances 1 }
|
||||
|
||||
|
||||
mbgXPTObjectsGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
mbgGPSRefclock1Type,
|
||||
mbgGPSRefclock1TypeVal,
|
||||
mbgGPSRefclock1Mode,
|
||||
mbgGPSRefclock1ModeVal,
|
||||
mbgGPSRef1GpsState,
|
||||
mbgGPSRef1GpsStateVal,
|
||||
mbgGPSRef1GpsPosition,
|
||||
mbgGPSRef1GpsSatellites,
|
||||
mbgGPSRef1GpsSatellitesGood,
|
||||
mbgGPSRef1GpsSatellitesInView,
|
||||
mbgGPSRefclock2Type,
|
||||
mbgGPSRefclock2TypeVal,
|
||||
mbgGPSRefclock2Mode,
|
||||
mbgGPSRefclock2ModeVal,
|
||||
mbgGPSRef2GpsState,
|
||||
mbgGPSRef2GpsStateVal,
|
||||
mbgGPSRef2GpsPosition,
|
||||
mbgGPSRef2GpsSatellites,
|
||||
mbgGPSRef2GpsSatellitesGood,
|
||||
mbgGPSRef2GpsSatellitesInView,
|
||||
mbgSCUType,
|
||||
mbgSCUTypeVal,
|
||||
mbgSCUMaster,
|
||||
mbgSCUMasterVal,
|
||||
mbgSCUMasterselect,
|
||||
mbgSCUMasterselectVal,
|
||||
mbgSCUTimeSync1,
|
||||
mbgSCUTimeSync2,
|
||||
mbgSCUTimelimitError,
|
||||
mbgSCUDisableOutputs,
|
||||
mbgSCUSelectedInput,
|
||||
mbgSCUSelectedInputVal,
|
||||
mbgSCUACOMode,
|
||||
mbgSCUPSUStatus,
|
||||
mbgSCUPSU1Status,
|
||||
mbgSCUPSU2Status
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The collection of objects for the MBG XPT MIB"
|
||||
|
||||
::= { mbgXPTGroups 1 }
|
||||
|
||||
mbgXPTTrapsGroup NOTIFICATION-GROUP
|
||||
NOTIFICATIONS {
|
||||
mbgGPSTrapColdBoot,
|
||||
mbgGPSTrapWarmBoot,
|
||||
mbgGPSNavSolved,
|
||||
mbgGPSTrapReceiverNotResponding,
|
||||
mbgGPSTrapReceiverNotSync,
|
||||
mbgGPSTrapAntennaFaulty,
|
||||
mbgGPSTrapAntennaReconnect,
|
||||
mbgGPSTrapLANXPTBoot,
|
||||
mbgGPSTrapLeapSecondAnnounced,
|
||||
mbgGPSTrapMasterclockSwitchover,
|
||||
mbgGPSTrapPowerSupplyFailure,
|
||||
mbgGPSTrapPowerSupplyOK,
|
||||
mbgGPSTrapTestNotification
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The collection of traps for the MBG XPT MIB"
|
||||
|
||||
::= { mbgXPTGroups 2 }
|
||||
|
||||
END
|
Reference in New Issue