Initial commit
This commit is contained in:
388
MIBS/mrv/NBS-PART-MIB
Normal file
388
MIBS/mrv/NBS-PART-MIB
Normal file
@ -0,0 +1,388 @@
|
||||
|
||||
NBS-PART-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY
|
||||
FROM SNMPv2-SMI
|
||||
|
||||
DisplayString
|
||||
FROM SNMPv2-TC
|
||||
|
||||
InterfaceIndex
|
||||
FROM IF-MIB
|
||||
|
||||
nbs, NbsTcPartIndex
|
||||
FROM NBS-MIB
|
||||
;
|
||||
|
||||
|
||||
nbsPartMib MODULE-IDENTITY
|
||||
LAST-UPDATED "201503090000Z" -- March 9, 2015
|
||||
ORGANIZATION "NBS"
|
||||
CONTACT-INFO
|
||||
"For technical support, please contact your service channel"
|
||||
DESCRIPTION
|
||||
"Identification and programming of field-serviceable components."
|
||||
|
||||
::= { nbs 231 }
|
||||
|
||||
-- *******************************************************************
|
||||
-- Groups in NBS-PART-MIB
|
||||
-- *******************************************************************
|
||||
|
||||
nbsPartHardGrp OBJECT-IDENTITY
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Information common to most system hardware components"
|
||||
::= { nbsPartMib 1 }
|
||||
|
||||
nbsPartFirmGrp OBJECT-IDENTITY
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Firmware information for system components"
|
||||
::= { nbsPartMib 2 }
|
||||
|
||||
nbsPartProgGrp OBJECT-IDENTITY
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Reprogrammable system components"
|
||||
::= { nbsPartMib 3 }
|
||||
|
||||
--nbsPartEventGrp OBJECT-IDENTITY
|
||||
-- STATUS current
|
||||
-- DESCRIPTION
|
||||
-- "NOTIFICATIONS"
|
||||
-- ::= { nbsPartMib 100 }
|
||||
|
||||
|
||||
|
||||
-- ********************************************************************
|
||||
--
|
||||
-- Objects for the nbsPartHard[ware]Grp group
|
||||
--
|
||||
-- ********************************************************************
|
||||
|
||||
nbsPartHardTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF NbsPartHardEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Attributes shared by most system hardware components."
|
||||
::= { nbsPartHardGrp 1 }
|
||||
|
||||
nbsPartHardEntry OBJECT-TYPE
|
||||
SYNTAX NbsPartHardEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Contains a description of a particular component"
|
||||
INDEX { nbsPartHardIfIndex, nbsPartHardPartIndex }
|
||||
::= { nbsPartHardTable 1 }
|
||||
|
||||
NbsPartHardEntry ::= SEQUENCE {
|
||||
nbsPartHardIfIndex InterfaceIndex,
|
||||
nbsPartHardPartIndex NbsTcPartIndex,
|
||||
nbsPartHardDescription DisplayString,
|
||||
nbsPartHardSerialNumber DisplayString,
|
||||
nbsPartHardProductionId DisplayString,
|
||||
nbsPartHardVendor DisplayString,
|
||||
nbsPartHardModel DisplayString,
|
||||
nbsPartHardWareRev DisplayString
|
||||
}
|
||||
|
||||
nbsPartHardIfIndex OBJECT-TYPE
|
||||
SYNTAX InterfaceIndex
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"If this part is a chassis, card, or port, this object is its
|
||||
own mib2-like ifIndex.
|
||||
|
||||
If this is any other kind of part, this object is the ifIndex
|
||||
of the chassis, card, or port of which it is a component."
|
||||
::= { nbsPartHardEntry 1 }
|
||||
|
||||
nbsPartHardPartIndex OBJECT-TYPE
|
||||
SYNTAX NbsTcPartIndex
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unique ID of this component within scope of nbsPartHardIfIndex"
|
||||
::= { nbsPartHardEntry 2 }
|
||||
|
||||
nbsPartHardDescription OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..100))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Human-readable identification of this part, including location"
|
||||
::= { nbsPartHardEntry 10 }
|
||||
|
||||
nbsPartHardSerialNumber OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..100))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Factory assigned unique identifier."
|
||||
::= { nbsPartHardEntry 11 }
|
||||
|
||||
nbsPartHardProductionId OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..50))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The 'Top Assembly Number' used in internal tracking"
|
||||
::= { nbsPartHardEntry 20 }
|
||||
|
||||
nbsPartHardVendor OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..50))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The manufacturer of this component"
|
||||
::= { nbsPartHardEntry 30 }
|
||||
|
||||
nbsPartHardModel OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..100))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Factory assigned model name/number."
|
||||
::= { nbsPartHardEntry 31 }
|
||||
|
||||
nbsPartHardWareRev OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..50))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The Hardware Revision number of this component."
|
||||
::= { nbsPartHardEntry 32 }
|
||||
|
||||
-- ********************************************************************
|
||||
--
|
||||
-- Objects for the nbsPartFirm[ware]Grp group
|
||||
--
|
||||
-- ********************************************************************
|
||||
|
||||
--
|
||||
-- nbsPartFirm[ware]Table
|
||||
--
|
||||
|
||||
nbsPartFirmTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF NbsPartFirmEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Firmware information for this part."
|
||||
::= { nbsPartFirmGrp 1 }
|
||||
|
||||
nbsPartFirmEntry OBJECT-TYPE
|
||||
SYNTAX NbsPartFirmEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Contains a description of a particular entity"
|
||||
INDEX { nbsPartFirmIfIndex, nbsPartFirmPartIndex }
|
||||
::= { nbsPartFirmTable 1 }
|
||||
|
||||
NbsPartFirmEntry ::= SEQUENCE {
|
||||
nbsPartFirmIfIndex InterfaceIndex,
|
||||
nbsPartFirmPartIndex NbsTcPartIndex,
|
||||
nbsPartFirmFpgaRev DisplayString,
|
||||
nbsPartFirmSwMajor INTEGER,
|
||||
nbsPartFirmSwMinor INTEGER,
|
||||
nbsPartFirmSwBuild INTEGER,
|
||||
nbsPartFirmWareIndex INTEGER -- loaded firmware, if available
|
||||
-- nbsPartFirmLoader INTEGER
|
||||
}
|
||||
|
||||
nbsPartFirmIfIndex OBJECT-TYPE
|
||||
SYNTAX InterfaceIndex
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"If this part is a chassis, card, or port, this object is its
|
||||
own mib2-like ifIndex.
|
||||
|
||||
If this is any other kind of part, this object is the ifIndex
|
||||
of the chassis, card, or port of which it is a component."
|
||||
::= { nbsPartFirmEntry 1 }
|
||||
|
||||
nbsPartFirmPartIndex OBJECT-TYPE
|
||||
SYNTAX NbsTcPartIndex
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unique ID of this component within scope of nbsPartFirmIfIndex"
|
||||
::= { nbsPartFirmEntry 2}
|
||||
|
||||
|
||||
nbsPartFirmFpgaRev OBJECT-TYPE
|
||||
SYNTAX DisplayString(SIZE(0..50))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The Firmware/FPGA Revision running on this component."
|
||||
::= { nbsPartFirmEntry 13 }
|
||||
|
||||
nbsPartFirmSwMajor OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The Major Revision Number of the software running on this
|
||||
component.
|
||||
|
||||
Not Supported value: -1"
|
||||
::= { nbsPartFirmEntry 14 }
|
||||
|
||||
nbsPartFirmSwMinor OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The Minor Revision Number of the software running on this
|
||||
component.
|
||||
|
||||
Not Supported value: -1"
|
||||
::= { nbsPartFirmEntry 15 }
|
||||
|
||||
nbsPartFirmSwBuild OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The Build Number of the software running on this component.
|
||||
|
||||
Not Supported value: -1"
|
||||
::= { nbsPartFirmEntry 16 }
|
||||
|
||||
nbsPartFirmWareIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The nbsCmmcSysFirmwareIndex of the firmware currently loaded.
|
||||
|
||||
Not Supported value: -1"
|
||||
::= { nbsPartFirmEntry 30 }
|
||||
|
||||
|
||||
|
||||
|
||||
-- ********************************************************************
|
||||
--
|
||||
-- Objects for the nbsPart[Re]Prog[rammable]Grp group
|
||||
--
|
||||
-- ********************************************************************
|
||||
|
||||
nbsPartProgTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF NbsPartProgEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A table that describes reprogrammable components."
|
||||
::= { nbsPartProgGrp 1 }
|
||||
|
||||
nbsPartProgEntry OBJECT-TYPE
|
||||
SYNTAX NbsPartProgEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Firmware of a particular reprogrammable component"
|
||||
INDEX { nbsPartProgIfIndex, nbsPartProgPartIndex }
|
||||
::= { nbsPartProgTable 1 }
|
||||
|
||||
NbsPartProgEntry ::= SEQUENCE {
|
||||
nbsPartProgIfIndex InterfaceIndex,
|
||||
nbsPartProgPartIndex NbsTcPartIndex,
|
||||
nbsPartProgFirmwareCaps OCTET STRING,
|
||||
nbsPartProgFirmwareLoad OCTET STRING,
|
||||
nbsPartProgLoader INTEGER,
|
||||
nbsPartProgNVAreaAdmin INTEGER,
|
||||
nbsPartProgNVAreaOper INTEGER,
|
||||
nbsPartProgNVAreaStart INTEGER,
|
||||
nbsPartProgNVAreaBanks INTEGER
|
||||
}
|
||||
|
||||
nbsPartProgIfIndex OBJECT-TYPE
|
||||
SYNTAX InterfaceIndex
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"If this part is a chassis, card, or port, this object is its
|
||||
own mib2-like ifIndex.
|
||||
|
||||
If this is any other kind of part, this object is the ifIndex
|
||||
of the chassis, card, or port of which it is a component."
|
||||
::= { nbsPartProgEntry 1 }
|
||||
|
||||
nbsPartProgPartIndex OBJECT-TYPE
|
||||
SYNTAX NbsTcPartIndex
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unique ID of this component within scope of nbsPartProgIfIndex"
|
||||
::= { nbsPartProgEntry 2 }
|
||||
|
||||
nbsPartProgFirmwareCaps OBJECT-TYPE
|
||||
SYNTAX OCTET STRING(SIZE(0..8))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"See nbsCmmcSlotFirmwareCaps."
|
||||
::= { nbsPartProgEntry 10 }
|
||||
|
||||
nbsPartProgFirmwareLoad OBJECT-TYPE
|
||||
SYNTAX OCTET STRING(SIZE(0..8))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"See nbsCmmcSlotFirmwareLoad"
|
||||
::= { nbsPartProgEntry 20 }
|
||||
|
||||
nbsPartProgLoader OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"See nbsCmmcSlotLoader"
|
||||
::= { nbsPartProgEntry 21 }
|
||||
|
||||
nbsPartProgNVAreaAdmin OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"See nbsCmmcSlotNVAreaAdmin"
|
||||
::= { nbsPartProgEntry 22 }
|
||||
|
||||
nbsPartProgNVAreaOper OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"See nbsCmmcSlotNVAreaOper"
|
||||
DEFVAL { -1 }
|
||||
::= { nbsPartProgEntry 23 }
|
||||
|
||||
nbsPartProgNVAreaStart OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The nbsCmmcSysNVAreaBank of this component's bank 1."
|
||||
::= { nbsPartProgEntry 30 }
|
||||
|
||||
nbsPartProgNVAreaBanks OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The number of NVAreaBanks on this component."
|
||||
::= { nbsPartProgEntry 31 }
|
||||
|
||||
|
||||
|
||||
|
||||
END
|
Reference in New Issue