-- Box Services MIB overview:
|
||||
-- Box Services MIB falls under ng7000managedswitch MIB node of the private subtree.
|
||||
|
||||
NETGEAR-BOXSERVICES-PRIVATE-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
-- Netgear Inc NETGEAR Box Services MIB
|
||||
-- Copyright Netgear Inc(2004-2008) All rights reserved.
|
||||
|
||||
-- This SNMP Management Information Specification
|
||||
-- embodies Netgear Inc's confidential and proprietary
|
||||
-- intellectual property. Netgear Inc retains all title
|
||||
-- and ownership in the Specification including any revisions.
|
||||
|
||||
-- This Specification is supplied "AS IS", Netgear Inc
|
||||
-- makes no warranty, either expressed or implied,
|
||||
-- as to the use, operation, condition, or performance of the
|
||||
-- Specification.
|
||||
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
|
||||
Unsigned32, Integer32 FROM SNMPv2-SMI
|
||||
TEXTUAL-CONVENTION FROM SNMPv2-TC
|
||||
DisplayString FROM RFC1213-MIB
|
||||
ng7000managedswitch FROM NETGEAR-REF-MIB;
|
||||
|
||||
fastPathBoxServices MODULE-IDENTITY
|
||||
LAST-UPDATED "201101260000Z" -- 26 Jan 2011 12:00:00 GMT
|
||||
ORGANIZATION "Netgear Inc"
|
||||
CONTACT-INFO ""
|
||||
|
||||
DESCRIPTION
|
||||
"The Netgear Private MIB for NETGEAR Box Services Feature."
|
||||
|
||||
-- Revision history.
|
||||
REVISION
|
||||
"201101260000Z" -- 26 Jan 2011 12:00:00 GMT
|
||||
DESCRIPTION
|
||||
"Postal address updated."
|
||||
REVISION
|
||||
"200802220000Z" -- 22 Feb 2008 12:00:00 GMT
|
||||
DESCRIPTION
|
||||
"Netgear branding related changes."
|
||||
|
||||
::= { ng7000managedswitch 43 }
|
||||
|
||||
BoxsTemperatureStatus ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The temperature state"
|
||||
SYNTAX INTEGER {
|
||||
low(0),
|
||||
normal(1),
|
||||
warning(2),
|
||||
critical(3),
|
||||
shutdown(4),
|
||||
notpresent(5),
|
||||
notoperational(6)
|
||||
}
|
||||
|
||||
--**************************************************************************************
|
||||
-- boxServicesGroup
|
||||
--
|
||||
-- This group provides configuration and status of the Box Services
|
||||
-- feature.
|
||||
--
|
||||
--**************************************************************************************
|
||||
|
||||
boxServicesGroup OBJECT IDENTIFIER ::= { fastPathBoxServices 1 }
|
||||
|
||||
--**************************************************************************************
|
||||
-- Some scalars
|
||||
|
||||
boxServicesNormalTempRangeMin OBJECT-TYPE
|
||||
SYNTAX Integer32 (-100..100)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" Lower boundary of normal temperature range."
|
||||
DEFVAL { 0 }
|
||||
::= { boxServicesGroup 1 }
|
||||
|
||||
boxServicesNormalTempRangeMax OBJECT-TYPE
|
||||
SYNTAX Integer32 (-100..100)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" Upper boundary of normal temperature range."
|
||||
DEFVAL { 45 }
|
||||
::= { boxServicesGroup 2 }
|
||||
|
||||
boxServicesTemperatureTrapEnable OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
enable(1),
|
||||
disable(2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" Enable or disable temperature change event trap, raised when temperature crosses boundaries of normal range"
|
||||
DEFVAL { enable }
|
||||
::= { boxServicesGroup 3 }
|
||||
|
||||
boxServicesPSMStateTrapEnable OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
enable(1),
|
||||
disable(2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" Enable or disable Power Supply Module state change trap."
|
||||
DEFVAL { enable }
|
||||
::= { boxServicesGroup 4 }
|
||||
|
||||
boxServicesFanStateTrapEnable OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
enable(1),
|
||||
disable(2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" Enable or disable Fan state change trap."
|
||||
DEFVAL { enable }
|
||||
::= { boxServicesGroup 5 }
|
||||
|
||||
|
||||
|
||||
boxServicesThermalShutdownSensor OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS accessible-for-notify
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The number of the sensor which initiated thermal shutdown."
|
||||
|
||||
::= { boxServicesGroup 13 }
|
||||
|
||||
boxServicesThermalShutdownTemperature OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS accessible-for-notify
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The temperature of the sensor which initiated thermal shutdown."
|
||||
|
||||
::= { boxServicesGroup 14 }
|
||||
|
||||
--**************************************************************************************
|
||||
-- boxServicesFans
|
||||
|
||||
boxServicesFansTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF BoxServicesFansEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Fan"
|
||||
::= { boxServicesGroup 6 }
|
||||
|
||||
boxServicesFansEntry OBJECT-TYPE
|
||||
SYNTAX BoxServicesFansEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Box Services Fan Entry"
|
||||
INDEX { boxServicesFanUnitIndex , boxServicesFansIndex }
|
||||
::= { boxServicesFansTable 1 }
|
||||
|
||||
BoxServicesFansEntry ::= SEQUENCE {
|
||||
boxServicesFanUnitIndex
|
||||
Unsigned32,
|
||||
boxServicesFansIndex
|
||||
Integer32,
|
||||
boxServicesFanItemType
|
||||
INTEGER,
|
||||
boxServicesFanItemState
|
||||
INTEGER,
|
||||
boxServicesFanSpeed
|
||||
OCTET STRING,
|
||||
boxServicesFanDutyLevel
|
||||
OCTET STRING
|
||||
}
|
||||
|
||||
boxServicesFanUnitIndex OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unit index for an entry in the Box Services Fan Table"
|
||||
::= { boxServicesFansEntry 6 }
|
||||
|
||||
boxServicesFansIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unique index of fan table entry"
|
||||
::= { boxServicesFansEntry 1 }
|
||||
|
||||
boxServicesFanItemType OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
fixed(1),
|
||||
removable(2),
|
||||
fixedAC(3),
|
||||
removableDC(4),
|
||||
fixedDC(5),
|
||||
removableAC(6)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The type of fan"
|
||||
::= { boxServicesFansEntry 2 }
|
||||
|
||||
|
||||
boxServicesFanItemState OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
notpresent(1),
|
||||
operational(2),
|
||||
failed(3),
|
||||
powering(4),
|
||||
nopower(5),
|
||||
notpowering(6),
|
||||
incompatible(7)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The status of fan. nopower(4) - This state means the fan is present but no AC is connected."
|
||||
::= { boxServicesFansEntry 3 }
|
||||
|
||||
|
||||
boxServicesFanSpeed OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (13))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The speed of fan"
|
||||
::= { boxServicesFansEntry 4}
|
||||
|
||||
boxServicesFanDutyLevel OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (13))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The duty level of fan, in percents"
|
||||
::= { boxServicesFansEntry 5}
|
||||
|
||||
|
||||
--**************************************************************************************
|
||||
-- boxServicesPowSupplies
|
||||
|
||||
boxServicesPowSuppliesTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF BoxServicesPowSuppliesEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Power supply"
|
||||
::= { boxServicesGroup 7 }
|
||||
|
||||
boxServicesPowSuppliesEntry OBJECT-TYPE
|
||||
SYNTAX BoxServicesPowSuppliesEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Box Services Power Supply Entry"
|
||||
INDEX { boxServicesPowerSuppUnitIndex, boxServicesPowSupplyIndex }
|
||||
::= { boxServicesPowSuppliesTable 1 }
|
||||
|
||||
BoxServicesPowSuppliesEntry ::= SEQUENCE {
|
||||
boxServicesPowerSuppUnitIndex
|
||||
Unsigned32,
|
||||
boxServicesPowSupplyIndex
|
||||
Integer32,
|
||||
boxServicesPowSupplyItemType
|
||||
INTEGER,
|
||||
boxServicesPowSupplyItemState
|
||||
INTEGER
|
||||
}
|
||||
|
||||
boxServicesPowerSuppUnitIndex OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unit index for an entry in the Box Services Power Supply Table"
|
||||
::= { boxServicesPowSuppliesEntry 4 }
|
||||
|
||||
boxServicesPowSupplyIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unique index of power supply table entry"
|
||||
::= { boxServicesPowSuppliesEntry 1 }
|
||||
|
||||
boxServicesPowSupplyItemType OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
fixed(1),
|
||||
removable(2),
|
||||
fixedAC(3),
|
||||
removableDC(4),
|
||||
fixedDC(5),
|
||||
removableAC(6)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The type of power supply"
|
||||
::= { boxServicesPowSuppliesEntry 2 }
|
||||
|
||||
|
||||
boxServicesPowSupplyItemState OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
notpresent(1),
|
||||
operational(2),
|
||||
failed(3),
|
||||
powering(4),
|
||||
nopower(5),
|
||||
notpowering(6),
|
||||
incompatible(7)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The status of power supply. nopower(5) - This state means the power supply is present but no AC is connected.
|
||||
incompatible(7) - This state is possible on boards capable of pluggable Power supplies"
|
||||
::= { boxServicesPowSuppliesEntry 3 }
|
||||
|
||||
|
||||
|
||||
--**************************************************************************************
|
||||
-- boxServicesTempSensors
|
||||
|
||||
|
||||
boxServicesTempSensorsTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF BoxServicesTempSensorsEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Temperature sensor"
|
||||
::= { boxServicesGroup 8 }
|
||||
|
||||
|
||||
boxServicesTempSensorsEntry OBJECT-TYPE
|
||||
SYNTAX BoxServicesTempSensorsEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Box Services Temperature Sensor Entry"
|
||||
INDEX { boxServicesUnitIndex, boxServicesTempSensorIndex }
|
||||
::= { boxServicesTempSensorsTable 1 }
|
||||
|
||||
BoxServicesTempSensorsEntry ::= SEQUENCE {
|
||||
boxServicesUnitIndex
|
||||
Unsigned32,
|
||||
boxServicesTempSensorIndex
|
||||
Unsigned32,
|
||||
boxServicesTempSensorType
|
||||
INTEGER,
|
||||
boxServicesTempSensorState
|
||||
BoxsTemperatureStatus,
|
||||
boxServicesTempSensorTemperature
|
||||
Integer32
|
||||
}
|
||||
|
||||
boxServicesUnitIndex OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unit index for an entry in the Box Services Temperature Sensor Table"
|
||||
::= { boxServicesTempSensorsEntry 1 }
|
||||
|
||||
boxServicesTempSensorIndex OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unique index of temperature sensor table entry"
|
||||
::= { boxServicesTempSensorsEntry 2 }
|
||||
|
||||
|
||||
boxServicesTempSensorType OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
fixed(1),
|
||||
removable(2),
|
||||
fixedAC(3),
|
||||
removableDC(4),
|
||||
fixedDC(5),
|
||||
removableAC(6)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The type of temperature sensor"
|
||||
::= { boxServicesTempSensorsEntry 3 }
|
||||
|
||||
|
||||
boxServicesTempSensorState OBJECT-TYPE
|
||||
SYNTAX BoxsTemperatureStatus
|
||||
MAX-ACCESS read-only
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"The state of temperature sensor"
|
||||
::= { boxServicesTempSensorsEntry 4 }
|
||||
|
||||
|
||||
boxServicesTempSensorTemperature OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The temperature value reported by sensor"
|
||||
::= { boxServicesTempSensorsEntry 5 }
|
||||
|
||||
boxServicesTempUnitTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF BoxServicesTempUnitEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Temperature status table"
|
||||
::= { boxServicesGroup 15 }
|
||||
|
||||
boxServicesTempUnitEntry OBJECT-TYPE
|
||||
SYNTAX BoxServicesTempUnitEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Box Services Temperature Unit Entry"
|
||||
INDEX { boxServicesTempUnitIndex }
|
||||
::= { boxServicesTempUnitTable 1 }
|
||||
|
||||
BoxServicesTempUnitEntry ::= SEQUENCE {
|
||||
boxServicesTempUnitIndex
|
||||
Unsigned32,
|
||||
boxServicesTempUnitState
|
||||
BoxsTemperatureStatus,
|
||||
boxServicesTempUnitTemperature
|
||||
Integer32
|
||||
}
|
||||
|
||||
boxServicesTempUnitIndex OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unit index for an entry in the Box Services Temperature Unit Table"
|
||||
::= { boxServicesTempUnitEntry 1 }
|
||||
|
||||
boxServicesTempUnitState OBJECT-TYPE
|
||||
SYNTAX BoxsTemperatureStatus
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The temperature state of the unit"
|
||||
::= { boxServicesTempUnitEntry 2 }
|
||||
|
||||
boxServicesTempUnitTemperature OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The highest temperature currently reported by any sensor on the unit"
|
||||
::= { boxServicesTempUnitEntry 3 }
|
||||
|
||||
--**************************************************************************************
|
||||
-- boxServicesNotificationsGroup
|
||||
--
|
||||
-- This group provides notification definitions for the Box Services
|
||||
-- feature.
|
||||
--
|
||||
--**************************************************************************************
|
||||
|
||||
boxServicesNotificationsGroup OBJECT IDENTIFIER ::= { fastPathBoxServices 2 }
|
||||
|
||||
--**************************************************************************************
|
||||
-- boxServices notification definitions
|
||||
|
||||
boxsItemStateChangeEvent OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
insertion(1),
|
||||
removal(2),
|
||||
becomeoperational(3),
|
||||
failure(4),
|
||||
losepower(5)
|
||||
}
|
||||
MAX-ACCESS accessible-for-notify
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This event describes states of the fan or power supply.
|
||||
|
||||
insertion - hot-pluggable fan or power supply was inserted
|
||||
removal - hot-pluggable fan or power supply was removed
|
||||
becomeoperational - fan or power supply became operational after failure state
|
||||
failure - fan or power supply failure happened, i.e. it is not able to perform its functions
|
||||
losepower - a power supply was operational, but the power to it has been disconnected or has failed"
|
||||
::= { boxServicesNotificationsGroup 1 }
|
||||
|
||||
boxsTemperatureChangeEvent OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
abovethreshold(1),
|
||||
belowthreshold(2),
|
||||
withinnormalrange(3)
|
||||
}
|
||||
MAX-ACCESS accessible-for-notify
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This event describes change of the temperature.
|
||||
To avoid flipping on boundary conditions, it is allowed to send the trap
|
||||
taking into account some margin around thresholds.
|
||||
|
||||
abovethreshold - temperature increased and crossed upper threshold value
|
||||
belowthreshold - temperature decreased and crossed lower threshold value
|
||||
withinnormalrange - temperature returned to normal range (between threshold)"
|
||||
::= { boxServicesNotificationsGroup 2 }
|
||||
|
||||
boxsTemperatureStatusCurrentEvent OBJECT-TYPE
|
||||
SYNTAX BoxsTemperatureStatus
|
||||
MAX-ACCESS accessible-for-notify
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This event describes the current status of a switch."
|
||||
::= { boxServicesNotificationsGroup 3 }
|
||||
|
||||
boxsTemperatureStatusPreviousEvent OBJECT-TYPE
|
||||
SYNTAX BoxsTemperatureStatus
|
||||
MAX-ACCESS accessible-for-notify
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This event describes the previous status of a switch."
|
||||
::= { boxServicesNotificationsGroup 4 }
|
||||
|
||||
|
||||
|
||||
--**************************************************************************************
|
||||
-- Traps
|
||||
--**************************************************************************************
|
||||
|
||||
fastPathBoxServicesTraps OBJECT IDENTIFIER ::= { fastPathBoxServices 0 }
|
||||
|
||||
|
||||
|
||||
boxsFanStateChange NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
boxServicesFansIndex,
|
||||
boxsItemStateChangeEvent
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap is sent when fan state change happens."
|
||||
::= { fastPathBoxServicesTraps 1 }
|
||||
|
||||
boxsPowSupplyStateChange NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
boxServicesPowSupplyIndex,
|
||||
boxsItemStateChangeEvent
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap is sent when power supply state change happens."
|
||||
::= { fastPathBoxServicesTraps 2 }
|
||||
|
||||
|
||||
boxsTemperatureChange NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
boxServicesTempSensorIndex,
|
||||
boxsTemperatureChangeEvent
|
||||
}
|
||||
STATUS obsolete
|
||||
DESCRIPTION
|
||||
"Trap is sent when temperature is changing and crossing any of the thresholds"
|
||||
::= { fastPathBoxServicesTraps 3 }
|
||||
|
||||
|
||||
boxsThermalShutdown NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
boxServicesThermalShutdownSensor,
|
||||
boxServicesThermalShutdownTemperature
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap is sent when thermal shutdown is initiated."
|
||||
::= { fastPathBoxServicesTraps 4 }
|
||||
|
||||
|
||||
boxsTemperatureStateChange NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
boxServicesTempUnitIndex,
|
||||
boxsTemperatureStatusCurrentEvent,
|
||||
boxsTemperatureStatusPreviousEvent
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap is sent when the system temperature crosses a threshold.
|
||||
To avoid rapid flapping between states, a hysteresis may
|
||||
be applied."
|
||||
::= { fastPathBoxServicesTraps 5 }
|
||||
|
||||
--**************************************************************************************
|
||||
-- Locator LED manage group
|
||||
--
|
||||
-- This group provides manage definitions for the Locator LED feature.
|
||||
--
|
||||
--**************************************************************************************
|
||||
|
||||
boxsLocatorLedConfigGroup OBJECT IDENTIFIER ::= { fastPathBoxServices 4 }
|
||||
|
||||
boxsLocatorLedUnit OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Spesifies unit number where Locator LED should blink on.
|
||||
This is write-only value. It always returns '0' on request
|
||||
if the Locator Led feature is supported."
|
||||
::= { boxsLocatorLedConfigGroup 1 }
|
||||
|
||||
boxsLocatorLedTime OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates time period in seconds for Locator LED blinking.
|
||||
The range is from 20 to 3600 seconds.
|
||||
The dafault value is 20 seconds.
|
||||
This is write-only value. It always returns '0' on request
|
||||
if the Locator Led feature is supported."
|
||||
DEFVAL { 20 }
|
||||
::= { boxsLocatorLedConfigGroup 2 }
|
||||
|
||||
boxsLocatorLedEnable OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
disable(0),
|
||||
enable(1)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Starts the Locator LED blinking.
|
||||
If boxsLocatorLedUnit has not been set current(manager) unit number will be used.
|
||||
If boxsLocatorLedTime has not been set default value(20 seconds) will be used.
|
||||
This is write-only value. It always returns '0' on request
|
||||
if the Locator Led feature is supported."
|
||||
::= { boxsLocatorLedConfigGroup 3 }
|
||||
|
||||