Initial commit
This commit is contained in:
		
							
								
								
									
										405
									
								
								MIBS/nokia/ALCATEL-IND1-INLINE-POWER-MIB
									
									
									
									
									
										Normal file
									
								
							
							
						
						
									
										405
									
								
								MIBS/nokia/ALCATEL-IND1-INLINE-POWER-MIB
									
									
									
									
									
										Normal file
									
								
							@@ -0,0 +1,405 @@
 | 
			
		||||
ALCATEL-IND1-INLINE-POWER-MIB DEFINITIONS ::= BEGIN
 | 
			
		||||
 | 
			
		||||
IMPORTS
 | 
			
		||||
	MODULE-IDENTITY, OBJECT-TYPE, Integer32, NOTIFICATION-TYPE
 | 
			
		||||
		FROM SNMPv2-SMI
 | 
			
		||||
	pethPsePortEntry, pethMainPseEntry
 | 
			
		||||
		FROM POWER-ETHERNET-MIB
 | 
			
		||||
        MODULE-COMPLIANCE, OBJECT-GROUP
 | 
			
		||||
		FROM SNMPv2-CONF
 | 
			
		||||
	softentIND1InLinePower, pethTraps
 | 
			
		||||
		FROM ALCATEL-IND1-BASE;
 | 
			
		||||
 | 
			
		||||
alcatelIND1INLINEPOWERMIB MODULE-IDENTITY
 | 
			
		||||
    LAST-UPDATED "200704030000Z" 
 | 
			
		||||
    ORGANIZATION "Alcatel-Lucent"
 | 
			
		||||
    CONTACT-INFO
 | 
			
		||||
        "Please consult with Customer Service to ensure the most appropriate
 | 
			
		||||
         version of this document is used with the products in question:
 | 
			
		||||
         
 | 
			
		||||
                    Alcatel-Lucent, Enterprise Solutions Division
 | 
			
		||||
                   (Formerly Alcatel Internetworking, Incorporated)
 | 
			
		||||
                           26801 West Agoura Road
 | 
			
		||||
                        Agoura Hills, CA  91301-5122
 | 
			
		||||
                          United States Of America
 | 
			
		||||
        
 | 
			
		||||
        Telephone:               North America  +1 800 995 2696
 | 
			
		||||
                                 Latin America  +1 877 919 9526
 | 
			
		||||
                                 Europe         +31 23 556 0100
 | 
			
		||||
                                 Asia           +65 394 7933
 | 
			
		||||
                                 All Other      +1 818 878 4507
 | 
			
		||||
        
 | 
			
		||||
        Electronic Mail:         support@ind.alcatel.com
 | 
			
		||||
        World Wide Web:          http://alcatel-lucent.com/wps/portal/enterprise
 | 
			
		||||
        File Transfer Protocol:  ftp://ftp.ind.alcatel.com/pub/products/mibs"
 | 
			
		||||
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "This module describes an authoritative enterprise-specific Simple
 | 
			
		||||
         Network Management Protocol (SNMP) Management Information Base (MIB):
 | 
			
		||||
         
 | 
			
		||||
             Propietary InLinePower Extensions MIB definitions
 | 
			
		||||
         
 | 
			
		||||
         The right to make changes in specification and other information
 | 
			
		||||
         contained in this document without prior notice is reserved.
 | 
			
		||||
         
 | 
			
		||||
         No liability shall be assumed for any incidental, indirect, special,
 | 
			
		||||
	 or consequential damages whatsoever arising from or related to this
 | 
			
		||||
         document or the information contained herein.
 | 
			
		||||
         
 | 
			
		||||
         Vendors, end-users, and other interested parties are granted
 | 
			
		||||
         non-exclusive license to use this specification in connection with
 | 
			
		||||
         management of the products for which it is intended to be used.
 | 
			
		||||
         
 | 
			
		||||
                     Copyright (C) 1995-2007 Alcatel-Lucent
 | 
			
		||||
                         ALL RIGHTS RESERVED WORLDWIDE"
 | 
			
		||||
 | 
			
		||||
    REVISION      "200704030000Z"
 | 
			
		||||
    DESCRIPTION
 | 
			
		||||
        "The latest version of this MIB Module."
 | 
			
		||||
 | 
			
		||||
    ::= { softentIND1InLinePower 1 }
 | 
			
		||||
 | 
			
		||||
   alaPethObjects       OBJECT IDENTIFIER ::= { alcatelIND1INLINEPOWERMIB 1 }
 | 
			
		||||
   alaPethConformance   OBJECT IDENTIFIER ::= { alcatelIND1INLINEPOWERMIB 2 }
 | 
			
		||||
   alaPethMain       	OBJECT IDENTIFIER ::= { alcatelIND1INLINEPOWERMIB 3 }
 | 
			
		||||
 | 
			
		||||
   -- PSE Objects
 | 
			
		||||
 | 
			
		||||
     alaPethPsePortTable OBJECT-TYPE
 | 
			
		||||
          SYNTAX      SEQUENCE OF AlaPethPsePortEntry
 | 
			
		||||
          MAX-ACCESS  not-accessible
 | 
			
		||||
          STATUS      current
 | 
			
		||||
          DESCRIPTION
 | 
			
		||||
              "A table of objects that augments the standard pethPsePortTable
 | 
			
		||||
              entry by adding the alaPethPsePortPowerMaximum object."
 | 
			
		||||
          ::= { alaPethObjects 1 }
 | 
			
		||||
 | 
			
		||||
      alaPethPsePortEntry OBJECT-TYPE
 | 
			
		||||
          SYNTAX      AlaPethPsePortEntry
 | 
			
		||||
          MAX-ACCESS  not-accessible
 | 
			
		||||
          STATUS      current
 | 
			
		||||
          DESCRIPTION
 | 
			
		||||
                  "A set of objects that display and control the power
 | 
			
		||||
                  characteristics of a power Ethernet PSE port."
 | 
			
		||||
          AUGMENTS  { pethPsePortEntry }  
 | 
			
		||||
          ::= { alaPethPsePortTable 1 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
      AlaPethPsePortEntry ::= SEQUENCE {
 | 
			
		||||
           alaPethPsePortPowerMaximum
 | 
			
		||||
                INTEGER,
 | 
			
		||||
           alaPethPsePortPowerActual
 | 
			
		||||
                INTEGER,
 | 
			
		||||
           alaPethPsePortPowerStatus
 | 
			
		||||
                INTEGER,
 | 
			
		||||
	   alaPethPsePortPowerClass
 | 
			
		||||
		INTEGER
 | 
			
		||||
      }
 | 
			
		||||
 | 
			
		||||
       alaPethPsePortPowerMaximum OBJECT-TYPE
 | 
			
		||||
       SYNTAX INTEGER ( 3000 .. 20000 )   
 | 
			
		||||
       MAX-ACCESS read-write
 | 
			
		||||
       STATUS current
 | 
			
		||||
       DESCRIPTION
 | 
			
		||||
           "This object controls maximum amount of power per port." 
 | 
			
		||||
       ::= { alaPethPsePortEntry 1 }
 | 
			
		||||
 | 
			
		||||
       alaPethPsePortPowerActual OBJECT-TYPE
 | 
			
		||||
       SYNTAX INTEGER ( 0 .. 30000 ) 
 | 
			
		||||
       MAX-ACCESS read-only
 | 
			
		||||
       STATUS current
 | 
			
		||||
       DESCRIPTION
 | 
			
		||||
           "This object contains the actual amount of power used by a port" 
 | 
			
		||||
       ::= { alaPethPsePortEntry 2 }
 | 
			
		||||
 | 
			
		||||
       alaPethPsePortPowerStatus OBJECT-TYPE
 | 
			
		||||
       SYNTAX INTEGER   {
 | 
			
		||||
                  powerOn(1),
 | 
			
		||||
                  powerOff(2)
 | 
			
		||||
       	   }
 | 
			
		||||
       MAX-ACCESS read-only
 | 
			
		||||
       STATUS current
 | 
			
		||||
       DESCRIPTION
 | 
			
		||||
           "This object contains the power status of a port" 
 | 
			
		||||
       ::= { alaPethPsePortEntry 3 }
 | 
			
		||||
 | 
			
		||||
       alaPethPsePortPowerClass OBJECT-TYPE
 | 
			
		||||
       SYNTAX INTEGER  {
 | 
			
		||||
                class0 (0),
 | 
			
		||||
                class1 (1),
 | 
			
		||||
                class2 (2),
 | 
			
		||||
                class3 (3),
 | 
			
		||||
                class4 (4),
 | 
			
		||||
                class5 (5)
 | 
			
		||||
                }
 | 
			
		||||
       MAX-ACCESS read-only
 | 
			
		||||
       STATUS current
 | 
			
		||||
       DESCRIPTION
 | 
			
		||||
           "This object controls class of poe device attached on a port.
 | 
			
		||||
           class0 - The device can draw PD power from 0.44W to 12.95W and
 | 
			
		||||
                    current less than 5.0 mA.
 | 
			
		||||
           class1 - The device can draw PD power from 0.44W to 3.84W and
 | 
			
		||||
                    current 10.5 mA.
 | 
			
		||||
           class2 - The device can draw PD power from 3.84W to 6.49W and
 | 
			
		||||
                    current 12.95 mA.
 | 
			
		||||
           class3 - The device can draw PD power from 6.49W to 12.95W and
 | 
			
		||||
                    current 28 mA.
 | 
			
		||||
           class4 - This class is reserved for future use.
 | 
			
		||||
           class5 - No Powered Device is connected to this POE port, or the
 | 
			
		||||
                                port is powered down."
 | 
			
		||||
       ::= { alaPethPsePortEntry 4 }
 | 
			
		||||
 | 
			
		||||
   -- Main PSE Objects
 | 
			
		||||
 | 
			
		||||
   alaPethMainPseTable OBJECT-TYPE
 | 
			
		||||
          SYNTAX      SEQUENCE OF AlaPethMainPseEntry
 | 
			
		||||
          MAX-ACCESS  not-accessible
 | 
			
		||||
          STATUS      current
 | 
			
		||||
          DESCRIPTION
 | 
			
		||||
              "This table augments the standard table PethMainPseTable by allowing the 
 | 
			
		||||
              admin status for a group to be set to on/off as well as
 | 
			
		||||
              showing the values for the max power for that group."
 | 
			
		||||
          ::= { alaPethObjects 2 }
 | 
			
		||||
 | 
			
		||||
      alaPethMainPseEntry OBJECT-TYPE
 | 
			
		||||
          SYNTAX      AlaPethMainPseEntry
 | 
			
		||||
          MAX-ACCESS  not-accessible
 | 
			
		||||
          STATUS      current
 | 
			
		||||
          DESCRIPTION
 | 
			
		||||
               "A set of objects that display and control the Main power
 | 
			
		||||
                of a PSE. "
 | 
			
		||||
          AUGMENTS  { pethMainPseEntry }  
 | 
			
		||||
          ::= { alaPethMainPseTable 1 }
 | 
			
		||||
 | 
			
		||||
      AlaPethMainPseEntry ::= SEQUENCE {
 | 
			
		||||
          alaPethMainPseAdminStatus
 | 
			
		||||
              INTEGER,
 | 
			
		||||
          alaPethMainPseMaxPower 
 | 
			
		||||
              Integer32,
 | 
			
		||||
          alaPethMainPsePriorityDisconnect
 | 
			
		||||
              INTEGER,
 | 
			
		||||
          alaPethMainPseCapacitorDetect
 | 
			
		||||
              INTEGER,
 | 
			
		||||
          alaPethMainPsePriority
 | 
			
		||||
              INTEGER,
 | 
			
		||||
          alaPethMainPseComboPort
 | 
			
		||||
              INTEGER
 | 
			
		||||
      }
 | 
			
		||||
 | 
			
		||||
        alaPethMainPseAdminStatus OBJECT-TYPE
 | 
			
		||||
          SYNTAX INTEGER   {
 | 
			
		||||
                  on(1),
 | 
			
		||||
                  off(2)
 | 
			
		||||
             }
 | 
			
		||||
          MAX-ACCESS  read-write
 | 
			
		||||
          STATUS      current
 | 
			
		||||
          DESCRIPTION
 | 
			
		||||
                  "The object is used to set the status of the main PSE to ON or OFF."
 | 
			
		||||
          ::= { alaPethMainPseEntry 1 }
 | 
			
		||||
 | 
			
		||||
        alaPethMainPseMaxPower OBJECT-TYPE
 | 
			
		||||
          SYNTAX      Integer32  (36..800)
 | 
			
		||||
          UNITS      "Watts"
 | 
			
		||||
          MAX-ACCESS  read-write
 | 
			
		||||
          STATUS      current
 | 
			
		||||
          DESCRIPTION
 | 
			
		||||
                  "The maximum amount of power allowed for main PSE." 
 | 
			
		||||
          ::= { alaPethMainPseEntry 2 }
 | 
			
		||||
          
 | 
			
		||||
        alaPethMainPsePriorityDisconnect OBJECT-TYPE
 | 
			
		||||
          SYNTAX INTEGER   {
 | 
			
		||||
                  enable(1),
 | 
			
		||||
                  disable(2)
 | 
			
		||||
             }
 | 
			
		||||
          MAX-ACCESS  read-write
 | 
			
		||||
          STATUS      current
 | 
			
		||||
          DESCRIPTION
 | 
			
		||||
                  "The object is used to set the priority disconnect of the
 | 
			
		||||
				   main PSE to Enabled or Disable."
 | 
			
		||||
          ::= { alaPethMainPseEntry 3 }
 | 
			
		||||
          
 | 
			
		||||
        alaPethMainPseCapacitorDetect OBJECT-TYPE
 | 
			
		||||
          SYNTAX INTEGER   {
 | 
			
		||||
                  enable(1),
 | 
			
		||||
                  disable(2)
 | 
			
		||||
             }
 | 
			
		||||
          MAX-ACCESS  read-write
 | 
			
		||||
          STATUS      current
 | 
			
		||||
          DESCRIPTION
 | 
			
		||||
                  "The object is used to enable or disable the PowerDsine 
 | 
			
		||||
				   Capacitor detection method." 
 | 
			
		||||
          ::= { alaPethMainPseEntry 4 }
 | 
			
		||||
          
 | 
			
		||||
        alaPethMainPsePriority OBJECT-TYPE
 | 
			
		||||
          SYNTAX INTEGER   {
 | 
			
		||||
                  critical(1),
 | 
			
		||||
                  high(2),
 | 
			
		||||
                  low(3)
 | 
			
		||||
             }
 | 
			
		||||
          MAX-ACCESS  read-write
 | 
			
		||||
          STATUS      current
 | 
			
		||||
          DESCRIPTION
 | 
			
		||||
                  "The object is set the power down priority for the slot"
 | 
			
		||||
          ::= { alaPethMainPseEntry 5 }
 | 
			
		||||
 | 
			
		||||
        alaPethMainPseComboPort OBJECT-TYPE
 | 
			
		||||
          SYNTAX INTEGER   {
 | 
			
		||||
                  enable(1),
 | 
			
		||||
                  disable(2)
 | 
			
		||||
             }
 | 
			
		||||
          MAX-ACCESS  read-write
 | 
			
		||||
          STATUS      current
 | 
			
		||||
          DESCRIPTION
 | 
			
		||||
                  "The object is used to set the combo port option of the
 | 
			
		||||
                  main PSE to Enable or Disable."
 | 
			
		||||
          ::= { alaPethMainPseEntry 6 }
 | 
			
		||||
          
 | 
			
		||||
   --
 | 
			
		||||
   -- Conformance Section
 | 
			
		||||
   --
 | 
			
		||||
   alaPethCompliances OBJECT IDENTIFIER ::= { alaPethConformance 1 }
 | 
			
		||||
   alaPethGroups      OBJECT IDENTIFIER ::= { alaPethConformance 2 }
 | 
			
		||||
 | 
			
		||||
   alaPethCompliance MODULE-COMPLIANCE
 | 
			
		||||
       STATUS  current
 | 
			
		||||
       DESCRIPTION
 | 
			
		||||
               "Describes the requirements for conformance to the
 | 
			
		||||
               Alcatel Power Ethernet MIB."
 | 
			
		||||
       MODULE  -- this module
 | 
			
		||||
           GROUP   alaPethPsePortGroup
 | 
			
		||||
           DESCRIPTION
 | 
			
		||||
               "The alaPethPsePortGroup is mandatory for systems which
 | 
			
		||||
               implement PSE ports."
 | 
			
		||||
           GROUP   alaPethMainPseGroup
 | 
			
		||||
           DESCRIPTION
 | 
			
		||||
               "The pethMainPseGroup is mandatory for systems which
 | 
			
		||||
               implement main power supply within a PSE Device."
 | 
			
		||||
   ::= { alaPethCompliances 1 }
 | 
			
		||||
 | 
			
		||||
   alaPethPseCompliance MODULE-COMPLIANCE
 | 
			
		||||
       STATUS  current
 | 
			
		||||
       DESCRIPTION
 | 
			
		||||
               "Describes the requirements for conformance to the PSE"
 | 
			
		||||
       MODULE  -- this module
 | 
			
		||||
       MANDATORY-GROUPS {alaPethPsePortGroup, alaPethMainPseGroup}
 | 
			
		||||
        ::= { alaPethCompliances 2 }
 | 
			
		||||
 | 
			
		||||
   alaPethPsePortGroup OBJECT-GROUP
 | 
			
		||||
       OBJECTS {
 | 
			
		||||
          alaPethPsePortPowerMaximum,
 | 
			
		||||
	  alaPethPsePortPowerActual,
 | 
			
		||||
          alaPethPsePortPowerStatus,
 | 
			
		||||
          alaPethPsePortPowerClass
 | 
			
		||||
       }
 | 
			
		||||
       STATUS  current
 | 
			
		||||
       DESCRIPTION
 | 
			
		||||
             "The pethPsePortGroup is mandatory for systems which
 | 
			
		||||
             implement PSE ports."
 | 
			
		||||
       ::= { alaPethGroups 1 }
 | 
			
		||||
 | 
			
		||||
   alaPethMainPseGroup OBJECT-GROUP
 | 
			
		||||
       OBJECTS {
 | 
			
		||||
		alaPethMainPseAdminStatus,
 | 
			
		||||
          	alaPethMainPseMaxPower,
 | 
			
		||||
                alaPethMainPsePriorityDisconnect,
 | 
			
		||||
        	alaPethMainPseCapacitorDetect,
 | 
			
		||||
        	alaPethMainPsePriority,
 | 
			
		||||
		alaPethMainPseComboPort
 | 
			
		||||
       }
 | 
			
		||||
       STATUS  current
 | 
			
		||||
       DESCRIPTION
 | 
			
		||||
               "Main PSE Objects. "
 | 
			
		||||
       ::= { alaPethGroups 2 }
 | 
			
		||||
 | 
			
		||||
   -- Peth Main
 | 
			
		||||
 | 
			
		||||
     alaPethMainTable OBJECT-TYPE
 | 
			
		||||
          SYNTAX      SEQUENCE OF AlaPethMainEntry
 | 
			
		||||
          MAX-ACCESS  not-accessible
 | 
			
		||||
          STATUS      current
 | 
			
		||||
          DESCRIPTION
 | 
			
		||||
              "A table of objects that augments the standard pethPsePortTable
 | 
			
		||||
              entry by adding the alaPethPsePortPowerMaximum object."
 | 
			
		||||
          ::= { alaPethMain 1 }
 | 
			
		||||
 | 
			
		||||
      alaPethMainEntry OBJECT-TYPE
 | 
			
		||||
          SYNTAX      AlaPethMainEntry
 | 
			
		||||
          MAX-ACCESS  not-accessible
 | 
			
		||||
          STATUS      current
 | 
			
		||||
          DESCRIPTION
 | 
			
		||||
                  "A set of objects that display and control the power
 | 
			
		||||
                  characteristics of a power Ethernet PSE port."
 | 
			
		||||
	      INDEX { alaPethMainIndex }
 | 
			
		||||
          ::= { alaPethMainTable 1 }
 | 
			
		||||
 | 
			
		||||
      AlaPethMainEntry ::= SEQUENCE {
 | 
			
		||||
           alaPethMainIndex
 | 
			
		||||
             Integer32,
 | 
			
		||||
           alaPethMainPowerRedundancy
 | 
			
		||||
                INTEGER
 | 
			
		||||
      }
 | 
			
		||||
        alaPethMainIndex OBJECT-TYPE
 | 
			
		||||
          SYNTAX       Integer32 (1..2147483647)
 | 
			
		||||
          MAX-ACCESS  not-accessible
 | 
			
		||||
          STATUS      current
 | 
			
		||||
          DESCRIPTION
 | 
			
		||||
              "This variable uniquely identifies the group to which
 | 
			
		||||
              power Ethernet PSE is connected.Group means (box in the stack,
 | 
			
		||||
              module in a rack) and  the value 1 MUST be  used for non-modular
 | 
			
		||||
              devices "
 | 
			
		||||
          ::= { alaPethMainEntry  1 }
 | 
			
		||||
 | 
			
		||||
       alaPethMainPowerRedundancy OBJECT-TYPE
 | 
			
		||||
	   SYNTAX INTEGER   {
 | 
			
		||||
                  enable(1),
 | 
			
		||||
                  disable(2)
 | 
			
		||||
       }
 | 
			
		||||
       MAX-ACCESS read-write
 | 
			
		||||
       STATUS current
 | 
			
		||||
       DESCRIPTION
 | 
			
		||||
           "This object controls power supply redundancy." 
 | 
			
		||||
       ::= { alaPethMainEntry  2 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
   -- Notification Objects
 | 
			
		||||
 | 
			
		||||
   alaPethNotificationObjects OBJECT IDENTIFIER ::= { alaPethObjects 3 }
 | 
			
		||||
 | 
			
		||||
	pethSourceSlot  OBJECT-TYPE
 | 
			
		||||
	    SYNTAX  INTEGER  (1..64)
 | 
			
		||||
	    MAX-ACCESS  read-only
 | 
			
		||||
	    STATUS  current
 | 
			
		||||
	    DESCRIPTION
 | 
			
		||||
		    "Slot number of generating entity."
 | 
			
		||||
          ::= { alaPethNotificationObjects 1 }
 | 
			
		||||
 | 
			
		||||
	pethSourcePort  OBJECT-TYPE
 | 
			
		||||
	    SYNTAX  INTEGER  (1..48)
 | 
			
		||||
	    MAX-ACCESS  read-only
 | 
			
		||||
	    STATUS  current
 | 
			
		||||
	    DESCRIPTION
 | 
			
		||||
		    "Port number of generating entity."
 | 
			
		||||
          ::= { alaPethNotificationObjects 2 }
 | 
			
		||||
 | 
			
		||||
   --  NOTIFICATIONS
 | 
			
		||||
 | 
			
		||||
	pethPwrSupplyConflict  NOTIFICATION-TYPE
 | 
			
		||||
	   OBJECTS {
 | 
			
		||||
	       pethSourceSlot
 | 
			
		||||
                   }
 | 
			
		||||
	   STATUS   current
 | 
			
		||||
	   DESCRIPTION 
 | 
			
		||||
	       "Power supply type conflict trap."
 | 
			
		||||
	    ::= { pethTraps 0 1 }
 | 
			
		||||
 | 
			
		||||
	pethPwrSupplyNotSupported  NOTIFICATION-TYPE
 | 
			
		||||
	   OBJECTS {
 | 
			
		||||
	       pethSourceSlot
 | 
			
		||||
                   }
 | 
			
		||||
	   STATUS   current
 | 
			
		||||
	   DESCRIPTION 
 | 
			
		||||
	       "Power supply not supported trap."
 | 
			
		||||
	    ::= { pethTraps 0 2 }
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
END
 | 
			
		||||
		Reference in New Issue
	