Initial commit
This commit is contained in:
822
MIBS/raisecom/RAISECOM-OPTICAL-MONITOR-MIB
Normal file
822
MIBS/raisecom/RAISECOM-OPTICAL-MONITOR-MIB
Normal file
@ -0,0 +1,822 @@
|
||||
--MibName=raisecomOpticalMonitorMIB
|
||||
-- *****************************************************************
|
||||
-- RAISECOM-OPTICAL-MONITOR-MIB.my
|
||||
--
|
||||
-- May 2006, chenyu
|
||||
--
|
||||
-- Copyright(c) 2003-2005 by RAISECOM TECH, Ltd.
|
||||
-- All rights reserved.
|
||||
-- *****************************************************************
|
||||
|
||||
|
||||
RAISECOM-OPTICAL-MONITOR-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
Integer32, Unsigned32,
|
||||
MODULE-IDENTITY,
|
||||
NOTIFICATION-TYPE,
|
||||
OBJECT-TYPE,
|
||||
TimeTicks FROM SNMPv2-SMI
|
||||
TEXTUAL-CONVENTION FROM SNMPv2-TC
|
||||
MODULE-COMPLIANCE,
|
||||
NOTIFICATION-GROUP,
|
||||
OBJECT-GROUP FROM SNMPv2-CONF
|
||||
ifIndex FROM IF-MIB
|
||||
EnableVar FROM SWITCH-TC
|
||||
raisecomAgent FROM RAISECOM-BASE-MIB;
|
||||
|
||||
raisecomOpticalMonitorMIB MODULE-IDENTITY
|
||||
LAST-UPDATED "200606060000Z"
|
||||
ORGANIZATION "Raisecom, Inc."
|
||||
CONTACT-INFO
|
||||
" Raise Systems
|
||||
|
||||
Postal: Beijing,
|
||||
China
|
||||
|
||||
Tel: 86-010-82884499
|
||||
|
||||
E-mail: chenyu@raisecom.com"
|
||||
DESCRIPTION
|
||||
"This MIB module defines objects to monitor optical
|
||||
characteristics on the optical interfaces in a network element. "
|
||||
REVISION "200606060000Z"
|
||||
DESCRIPTION
|
||||
"The initial revision of this MIB."
|
||||
::={ raisecomAgent 9 }
|
||||
|
||||
|
||||
-- Textual Conventions
|
||||
|
||||
OpticalParameterType ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This value indicates the optical parameter that is
|
||||
being monitored. Valid values are -
|
||||
|
||||
temperature(1)
|
||||
supplyVoltage(2)
|
||||
biasCurrent(3)
|
||||
txOutputPower(4)
|
||||
receivedPower(5) "
|
||||
SYNTAX INTEGER {
|
||||
temperature(1),
|
||||
supplyVoltage(2),
|
||||
biasCurrent(3),
|
||||
txOutputPower(4),
|
||||
receivedPower(5)
|
||||
}
|
||||
|
||||
|
||||
OpticalParameterValue ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The value of the optical parameter that is being monitored.
|
||||
|
||||
The range of values varies depending on the type of optical
|
||||
parameter being monitored, as identified by a corresponding
|
||||
object with syntax OpticalParameterType.
|
||||
|
||||
When the optical parameter being monitored is 'temperature',
|
||||
the supported range is from -32768 to 32768, in units of
|
||||
1/256 degrees centigrade.
|
||||
Example: A value of 6016 represents a temperature reading of
|
||||
23.5 degrees C.
|
||||
|
||||
When the optical parameter being monitored is 'supplyVoltage',
|
||||
the supported range is from 0 to 65535, in units of 1/10 millivolts.
|
||||
Example: A value of 55000 represents a supplyVoltage reading of
|
||||
5.5 V.
|
||||
|
||||
When the optical parameter being monitored is 'biasCurrent',
|
||||
the supported range is from 0 to 65535, in units of 1/500
|
||||
microamperes.
|
||||
Example: A value of 500 represents a bias current reading of
|
||||
1 microamperes.
|
||||
|
||||
When the optical parameter being monitored is 'txOutputPower',
|
||||
the supported range is from 0 to 65535, in units of 1/10000 mW ..and express in units of dBm<42><6D>
|
||||
Example: A value of 60000 represents a txOutputPower reading of 7.78 dBm.
|
||||
|
||||
When the optical parameter being monitored is 'receivedPower',
|
||||
the supported range is from 0 to 65535, in units of 1/10000 mW ..and express in units of dBm<42><6D>
|
||||
Example: A value of 60000 represents a receivedPower reading of 7.78 dBm. "
|
||||
SYNTAX Integer32 (-1000000..65535 )
|
||||
|
||||
OpticalPMPeriod ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This value indicates the time period over which performance
|
||||
monitoring data has been collected."
|
||||
SYNTAX INTEGER {
|
||||
fifteenMin(1),
|
||||
twentyFourHour(2)
|
||||
}
|
||||
|
||||
-- MIB Object Definitions
|
||||
|
||||
raisecomOpticalMonitorMIBObjects OBJECT IDENTIFIER ::=
|
||||
{raisecomOpticalMonitorMIB 1 }
|
||||
|
||||
-- groups in this MIB module
|
||||
|
||||
raisecomOpticalMonGroup OBJECT IDENTIFIER ::=
|
||||
{raisecomOpticalMonitorMIBObjects 1 }
|
||||
|
||||
raisecomOpticalPMGroup OBJECT IDENTIFIER ::=
|
||||
{raisecomOpticalMonitorMIBObjects 2 }
|
||||
|
||||
-- raisecomTranceiverInfoTable
|
||||
|
||||
raisecomTranceiverInfoTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RaisecomTranceiverInfoEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trancetver information Table."
|
||||
::= { raisecomOpticalMonitorMIBObjects 4 }
|
||||
|
||||
raisecomTranceiverInfoEntry OBJECT-TYPE
|
||||
SYNTAX RaisecomTranceiverInfoEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the raisecomSfpAccessA0Table."
|
||||
INDEX { ifIndex }
|
||||
::={ raisecomTranceiverInfoTable 1 }
|
||||
|
||||
|
||||
RaisecomTranceiverInfoEntry ::= SEQUENCE {
|
||||
raisecomTranceiverType OCTET STRING,
|
||||
raisecomTranceiverConnectorType OCTET STRING,
|
||||
raisecomTranceiverWavelength Integer32,
|
||||
raisecomTranceiverVendorName OCTET STRING,
|
||||
raisecomTranceiverVendorPN OCTET STRING,
|
||||
raisecomTranceiverVendorSN OCTET STRING,
|
||||
raisecomTransceiverFiberType INTEGER,
|
||||
raisecomTransceiverTransferDistance Integer32
|
||||
}
|
||||
|
||||
raisecomTranceiverType OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Type of the interface, such as 1000_BASE_SX_SFP"
|
||||
::= { raisecomTranceiverInfoEntry 1 }
|
||||
|
||||
raisecomTranceiverConnectorType OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"ConnectorType of the interface, such as SC/LC"
|
||||
::= { raisecomTranceiverInfoEntry 2 }
|
||||
|
||||
raisecomTranceiverWavelength OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Wavelength of the interface, measured in nm."
|
||||
::= { raisecomTranceiverInfoEntry 3 }
|
||||
|
||||
raisecomTranceiverVendorName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Vendor name of the interface."
|
||||
::= { raisecomTranceiverInfoEntry 4 }
|
||||
|
||||
raisecomTranceiverVendorPN OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Vendor part number of the interface."
|
||||
::= { raisecomTranceiverInfoEntry 5 }
|
||||
|
||||
raisecomTranceiverVendorSN OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Vendor serial number of the interface."
|
||||
::= { raisecomTranceiverInfoEntry 6 }
|
||||
|
||||
raisecomTransceiverFiberType OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
single-mode(1),
|
||||
multi-mode(2),
|
||||
none(3)
|
||||
}
|
||||
ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Types of the fiber,
|
||||
single_mode, multi_mode, none."
|
||||
::= { raisecomTranceiverInfoEntry 7 }
|
||||
|
||||
raisecomTransceiverTransferDistance OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The max distance which the interface could transmit,
|
||||
measured in meter."
|
||||
::= { raisecomTranceiverInfoEntry 8 }
|
||||
|
||||
|
||||
|
||||
|
||||
-- raisecomOpticalMonTable
|
||||
|
||||
raisecomOpticalMonTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RaisecomOpticalMonEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table provides objects to monitor optical
|
||||
parameters in a network element. "
|
||||
::={ raisecomOpticalMonGroup 1 }
|
||||
|
||||
raisecomOpticalMonEntry OBJECT-TYPE
|
||||
SYNTAX RaisecomOpticalMonEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the raisecomOpticalMonTable provides objects to
|
||||
monitor an optical parameter at an optical interface.
|
||||
"
|
||||
INDEX { ifIndex, raisecomOpticalMonParameterType }
|
||||
::={ raisecomOpticalMonTable 1 }
|
||||
|
||||
|
||||
RaisecomOpticalMonEntry ::= SEQUENCE {
|
||||
raisecomOpticalMonParameterType OpticalParameterType,
|
||||
raisecomOpticalParameterValue OpticalParameterValue,
|
||||
raisecomOpticalParamHighAlarmThresh OpticalParameterValue,
|
||||
raisecomOpticalParamHighWarningThresh OpticalParameterValue,
|
||||
raisecomOpticalParamLowAlarmThresh OpticalParameterValue,
|
||||
raisecomOpticalParamLowWarningThresh OpticalParameterValue,
|
||||
raisecomOpticalParamAlarmStatus INTEGER,
|
||||
raisecomOpticalParamAlarmLastValue OpticalParameterValue,
|
||||
raisecomOpticalParamAlarmLastChange TimeTicks,
|
||||
raisecomOpticalMon15MinValidIntervals Unsigned32,
|
||||
raisecomOpticalMon24HrValidIntervals Unsigned32,
|
||||
raisecomOpticalMonValidStatus INTEGER
|
||||
}
|
||||
|
||||
raisecomOpticalMonParameterType OBJECT-TYPE
|
||||
SYNTAX OpticalParameterType
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object specifies the optical parameter that is being
|
||||
monitored in this entry."
|
||||
::={ raisecomOpticalMonEntry 1 }
|
||||
|
||||
raisecomOpticalParameterValue OBJECT-TYPE
|
||||
SYNTAX OpticalParameterValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object gives the value measured for the particular
|
||||
optical parameter specified by the raisecomOpticalMonParameterType
|
||||
object."
|
||||
::={ raisecomOpticalMonEntry 2 }
|
||||
|
||||
raisecomOpticalParamHighAlarmThresh OBJECT-TYPE
|
||||
SYNTAX OpticalParameterValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object gives the high alarm threshold on the
|
||||
optical parameter being monitored.
|
||||
|
||||
An alarm condition will be raised if the value given by
|
||||
raisecomOpticalParameterValue goes from below the value of
|
||||
this object to above the value of this object, or if
|
||||
the initial value of raisecomOpticalParameterValue exceeds the value
|
||||
of this object. This alarm will be indicated in the
|
||||
raisecomOpticalParamAlarmStatus object."
|
||||
::={ raisecomOpticalMonEntry 3 }
|
||||
|
||||
raisecomOpticalParamHighWarningThresh OBJECT-TYPE
|
||||
SYNTAX OpticalParameterValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set a high warning threshold on
|
||||
the optical parameter being monitored.
|
||||
|
||||
A threshold crossing condition will be indicated if the value
|
||||
given by raisecomOpticalParameterValue goes from below the value
|
||||
of this object to above the value of this
|
||||
object, or if the initial value of raisecomOpticalParameterValue
|
||||
exceeds the value of this object. This alarm will be indicated in the
|
||||
raisecomOpticalParamAlarmStatus object.
|
||||
"
|
||||
::={ raisecomOpticalMonEntry 4 }
|
||||
|
||||
raisecomOpticalParamLowAlarmThresh OBJECT-TYPE
|
||||
SYNTAX OpticalParameterValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set a low alarm threshold on the
|
||||
optical parameter being monitored.
|
||||
|
||||
An alarm condition will be raised if the value given by
|
||||
raisecomOpticalParameterValue goes from above the value of
|
||||
this object to below the value of this object, or if
|
||||
the initial value of raisecomOpticalParameterValue is lower than the
|
||||
value of this object. This alarm
|
||||
will be indicated in the raisecomOpticalParamAlarmStatus object .."
|
||||
::={ raisecomOpticalMonEntry 5 }
|
||||
|
||||
raisecomOpticalParamLowWarningThresh OBJECT-TYPE
|
||||
SYNTAX OpticalParameterValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to set a low warning threshold on
|
||||
the optical parameter being monitored.
|
||||
|
||||
A threshold crossing condition will be indicated if the value
|
||||
given by raisecomOpticalParameterValue goes from above the value
|
||||
of this object to below the value of this
|
||||
object, or if the initial value of raisecomOpticalParameterValue
|
||||
object is lower than the value of this object. For
|
||||
network elements in the status
|
||||
indications, this threshold violation will be indicated in the
|
||||
raisecomOpticalParamAlarmStatus object ."
|
||||
::={ raisecomOpticalMonEntry 6 }
|
||||
|
||||
raisecomOpticalParamAlarmStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
none(0),
|
||||
high-alarm-threshold(1),
|
||||
high-warning-threshold(2),
|
||||
low-alarm-threshold(3),
|
||||
low-warning-threshold(4)
|
||||
}
|
||||
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object is used to indicate the current status of
|
||||
the thresholds for the monitored optical parameter
|
||||
on the interface.
|
||||
|
||||
If a threshold is currently being exceeded on the
|
||||
interface, the object will be set. Otherwise,
|
||||
the object will be set to 0."
|
||||
::={ raisecomOpticalMonEntry 7 }
|
||||
|
||||
raisecomOpticalParamAlarmLastValue OBJECT-TYPE
|
||||
SYNTAX OpticalParameterValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the optical parameter value at the last time
|
||||
a threshold related to a particular optical parameter was
|
||||
exceeded on the interface.
|
||||
If no threshold value is currently being
|
||||
exceeded, then the value '-1000000' is returned."
|
||||
::={ raisecomOpticalMonEntry 8 }
|
||||
|
||||
raisecomOpticalParamAlarmLastChange OBJECT-TYPE
|
||||
SYNTAX TimeTicks
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object specifies the value of sysUpTime at the last time
|
||||
a threshold related to a particular optical parameter was
|
||||
exceeded on the interface."
|
||||
::={ raisecomOpticalMonEntry 9 }
|
||||
|
||||
raisecomOpticalMon15MinValidIntervals OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (0..96)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object gives the number of previous 15 minute
|
||||
intervals for which valid performance monitoring data
|
||||
has been stored on the interface.
|
||||
|
||||
The value of this object will be n (where n is the maximum
|
||||
number of 15 minute intervals supported at this interface),
|
||||
unless the measurement was (re-)started within the last
|
||||
(nx15) minutes, in which case the value will be the
|
||||
number of previous 15 minute intervals for which the agent
|
||||
has some data."
|
||||
::={ raisecomOpticalMonEntry 10 }
|
||||
|
||||
raisecomOpticalMon24HrValidIntervals OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (0..1)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object gives the number of previous 24 hour
|
||||
intervals for which valid performance monitoring data
|
||||
has been stored on the interface.
|
||||
|
||||
The value of this object will be 0 if the measurement
|
||||
was (re-)started within the last 24 hours, or 1 otherwise."
|
||||
::={ raisecomOpticalMonEntry 11 }
|
||||
|
||||
raisecomOpticalMonValidStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
valid(1),
|
||||
invalid(2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates the parameter row is valid or not."
|
||||
::={ raisecomOpticalMonEntry 12 }
|
||||
|
||||
-- Notification related objects
|
||||
|
||||
raisecomOpticalNotifyEnable OBJECT-TYPE
|
||||
SYNTAX EnableVar
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object specifies the generation of raisecomOpticalMonParameterStatus notifications.
|
||||
"
|
||||
DEFVAL { enable}
|
||||
::={ raisecomOpticalMonGroup 2 }
|
||||
|
||||
raisecomOpticalDigitalDiagnoticEnable OBJECT-TYPE
|
||||
SYNTAX EnableVar
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enable or disable digitaldiagnotic on the switch."
|
||||
DEFVAL { disable}
|
||||
::={ raisecomOpticalMonGroup 3 }
|
||||
|
||||
-- raisecomOpticalPMCurrent Table
|
||||
|
||||
raisecomOpticalPMCurrentTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RaisecomOpticalPMCurrentEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains performance monitoring data for the
|
||||
various optical parameters, collected over the current 15
|
||||
minute or the current 24 hour interval."
|
||||
::={ raisecomOpticalPMGroup 1 }
|
||||
|
||||
raisecomOpticalPMCurrentEntry OBJECT-TYPE
|
||||
SYNTAX RaisecomOpticalPMCurrentEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the raisecomOpticalPMCurrentTable. It contains
|
||||
performance monitoring data for a monitored optical
|
||||
parameter at an interface, collected over the current 15
|
||||
minute or the current 24 hour interval.
|
||||
"
|
||||
INDEX { ifIndex,
|
||||
raisecomOpticalPMCurrentPeriod,
|
||||
raisecomOpticalPMCurrentParamType }
|
||||
::={ raisecomOpticalPMCurrentTable 1 }
|
||||
|
||||
RaisecomOpticalPMCurrentEntry ::= SEQUENCE {
|
||||
raisecomOpticalPMCurrentPeriod OpticalPMPeriod,
|
||||
raisecomOpticalPMCurrentParamType OpticalParameterType,
|
||||
raisecomOpticalPMCurrentMaxParam OpticalParameterValue,
|
||||
raisecomOpticalPMCurrentMinParam OpticalParameterValue,
|
||||
raisecomOpticalPMCurrentMeanParam OpticalParameterValue
|
||||
}
|
||||
|
||||
raisecomOpticalPMCurrentPeriod OBJECT-TYPE
|
||||
SYNTAX OpticalPMPeriod
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates whether the optical parameter values
|
||||
given in this entry are collected over the current 15 minute or
|
||||
the current 24 hour interval."
|
||||
::={ raisecomOpticalPMCurrentEntry 1 }
|
||||
|
||||
raisecomOpticalPMCurrentParamType OBJECT-TYPE
|
||||
SYNTAX OpticalParameterType
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object specifies the optical parameter that is being
|
||||
monitored, in this entry."
|
||||
::={ raisecomOpticalPMCurrentEntry 2 }
|
||||
|
||||
raisecomOpticalPMCurrentMaxParam OBJECT-TYPE
|
||||
SYNTAX OpticalParameterValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object gives the maximum value measured for the monitored
|
||||
optical parameter, in the current 15 minute or the current
|
||||
24 hour interval."
|
||||
::={ raisecomOpticalPMCurrentEntry 3 }
|
||||
|
||||
raisecomOpticalPMCurrentMinParam OBJECT-TYPE
|
||||
SYNTAX OpticalParameterValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object gives the minimum value measured for the monitored
|
||||
optical parameter, in the current 15 minute or the current
|
||||
24 hour interval."
|
||||
::={ raisecomOpticalPMCurrentEntry 4 }
|
||||
|
||||
raisecomOpticalPMCurrentMeanParam OBJECT-TYPE
|
||||
SYNTAX OpticalParameterValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object gives the average value of the monitored
|
||||
optical parameter, in the current 15 minute or the current
|
||||
24 hour interval."
|
||||
::={ raisecomOpticalPMCurrentEntry 5 }
|
||||
|
||||
-- raisecomOpticalPMInterval Table
|
||||
|
||||
raisecomOpticalPMIntervalTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RaisecomOpticalPMIntervalEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table stores performance monitoring data for the
|
||||
various optical parameters, collected over previous
|
||||
intervals.
|
||||
|
||||
This table can have entries for one complete 24 hour
|
||||
interval and up to 96 complete 15 minute
|
||||
intervals. A system is required to store at least
|
||||
4 completed 15 minute intervals. The number of valid
|
||||
15 minute intervals in this table is indicated by the
|
||||
cOpticalMon15MinValidIntervals object and the number of
|
||||
valid 24 hour intervals is indicated by the
|
||||
cOpticalMon24HrValidIntervals object."
|
||||
::={ raisecomOpticalPMGroup 2 }
|
||||
|
||||
raisecomOpticalPMIntervalEntry OBJECT-TYPE
|
||||
SYNTAX RaisecomOpticalPMIntervalEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the raisecomOpticalPMIntervalTable. It contains
|
||||
performance monitoring data for an optical parameter,
|
||||
collected over a previous interval.
|
||||
"
|
||||
INDEX { ifIndex,
|
||||
raisecomOpticalPMIntervalPeriod,
|
||||
raisecomOpticalPMIntervalNumber,
|
||||
raisecomOpticalPMIntervalParamType }
|
||||
::={ raisecomOpticalPMIntervalTable 1 }
|
||||
|
||||
RaisecomOpticalPMIntervalEntry ::= SEQUENCE {
|
||||
raisecomOpticalPMIntervalPeriod OpticalPMPeriod,
|
||||
raisecomOpticalPMIntervalNumber Integer32,
|
||||
raisecomOpticalPMIntervalParamType OpticalParameterType,
|
||||
raisecomOpticalPMIntervalMaxParam OpticalParameterValue,
|
||||
raisecomOpticalPMIntervalMinParam OpticalParameterValue,
|
||||
raisecomOpticalPMIntervalMeanParam OpticalParameterValue
|
||||
}
|
||||
|
||||
raisecomOpticalPMIntervalPeriod OBJECT-TYPE
|
||||
SYNTAX OpticalPMPeriod
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object indicates whether the optical parameter values,
|
||||
given in this entry, are collected over a period of 15 minutes
|
||||
or 24 hours."
|
||||
::={ raisecomOpticalPMIntervalEntry 1 }
|
||||
|
||||
raisecomOpticalPMIntervalNumber OBJECT-TYPE
|
||||
SYNTAX Integer32 (1..96)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A number between 1 and 96, which identifies the
|
||||
interval for which the set of optical parameter values is
|
||||
available. The interval identified by 1 is the most recently
|
||||
completed 15 minute or 24 hour interval, and the interval
|
||||
identified by N is the interval immediately preceding the one
|
||||
identified by N-1."
|
||||
::={ raisecomOpticalPMIntervalEntry 2 }
|
||||
|
||||
raisecomOpticalPMIntervalParamType OBJECT-TYPE
|
||||
SYNTAX OpticalParameterType
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object specifies the optical parameter that is being
|
||||
monitored, in this entry."
|
||||
::={ raisecomOpticalPMIntervalEntry 3 }
|
||||
|
||||
raisecomOpticalPMIntervalMaxParam OBJECT-TYPE
|
||||
SYNTAX OpticalParameterValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object gives the maximum value measured for the optical
|
||||
parameter, in a particular 15 minute or 24 hour interval."
|
||||
::={ raisecomOpticalPMIntervalEntry 4 }
|
||||
|
||||
raisecomOpticalPMIntervalMinParam OBJECT-TYPE
|
||||
SYNTAX OpticalParameterValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object gives the minimum value measured for the optical
|
||||
parameter, in a particular 15 minute or 24 hour interval."
|
||||
::={ raisecomOpticalPMIntervalEntry 5 }
|
||||
|
||||
raisecomOpticalPMIntervalMeanParam OBJECT-TYPE
|
||||
SYNTAX OpticalParameterValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object gives the average value of the measured optical
|
||||
parameter, in a particular 15 minute or 24 hour interval."
|
||||
::={ raisecomOpticalPMIntervalEntry 6 }
|
||||
|
||||
|
||||
-- Notifications
|
||||
|
||||
raisecomOpticalMonitorMIBNotifications OBJECT IDENTIFIER ::=
|
||||
{ raisecomOpticalMonitorMIB 2 }
|
||||
|
||||
raisecomOpticalMonParameterStatus NOTIFICATION-TYPE
|
||||
OBJECTS { raisecomOpticalParameterValue,
|
||||
raisecomOpticalParamAlarmStatus
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This notification is sent when any threshold related to an
|
||||
optical parameter is exceeded on an interface.
|
||||
|
||||
This notification may be suppressed under the following
|
||||
conditions:
|
||||
- depending on the value of the raisecomOpticalNotifyEnable object.
|
||||
"
|
||||
::={ raisecomOpticalMonitorMIBNotifications 1 }
|
||||
|
||||
-- MIB Conformance Statements
|
||||
|
||||
raisecomOpticalMonitorMIBConformance OBJECT IDENTIFIER ::=
|
||||
{ raisecomOpticalMonitorMIB 3 }
|
||||
|
||||
raisecomOpticalMonitorMIBCompliances OBJECT IDENTIFIER ::=
|
||||
{ raisecomOpticalMonitorMIBConformance 1 }
|
||||
|
||||
raisecomOpticalMonitorMIBGroups OBJECT IDENTIFIER ::=
|
||||
{ raisecomOpticalMonitorMIBConformance 2 }
|
||||
|
||||
|
||||
raisecomOpticalMonitorMIBCompliance MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The compliance statement for network elements that
|
||||
monitor optical characteristics and thresholds on the
|
||||
optical interfaces in a network element."
|
||||
MODULE -- this module
|
||||
MANDATORY-GROUPS { raisecomOpticalMIBMonGroup }
|
||||
|
||||
GROUP raisecomOpticalMIBThresholdGroup
|
||||
DESCRIPTION
|
||||
"This group is required for network elements that support
|
||||
thresholds on optical parameters."
|
||||
|
||||
GROUP raisecomOpticalMIBPMGroup
|
||||
DESCRIPTION
|
||||
"This group is required for network elements that
|
||||
support collection of optical performance monitoring
|
||||
data for 15 minute or 24 hour intervals."
|
||||
|
||||
GROUP raisecomOpticalMIBNotifyEnableGroup
|
||||
DESCRIPTION
|
||||
"This group is required for network elements that
|
||||
support the cOpticalMIBNotifGroup."
|
||||
|
||||
GROUP raisecomOpticalMIBNotifGroup
|
||||
DESCRIPTION
|
||||
"This group is required for network elements that
|
||||
generate notifications when a threshold is exceeded or
|
||||
cleared on an interface."
|
||||
|
||||
OBJECT raisecomOpticalParamHighAlarmThresh
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT raisecomOpticalParamHighWarningThresh
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT raisecomOpticalParamLowAlarmThresh
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT raisecomOpticalParamLowWarningThresh
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT raisecomOpticalParamHighAlarmSev
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT raisecomOpticalParamHighWarningSev
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT raisecomOpticalParamLowAlarmSev
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
OBJECT raisecomOpticalParamLowWarningSev
|
||||
MIN-ACCESS read-only
|
||||
DESCRIPTION
|
||||
"Write access is not required."
|
||||
|
||||
::={ raisecomOpticalMonitorMIBCompliances 1 }
|
||||
|
||||
-- Units of Conformance
|
||||
|
||||
raisecomOpticalMIBMonGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
raisecomOpticalParameterValue
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A mandatory object that provides monitoring of optical
|
||||
characteristics."
|
||||
::={ raisecomOpticalMonitorMIBGroups 1 }
|
||||
|
||||
raisecomOpticalMIBThresholdGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
raisecomOpticalParamHighAlarmThresh,
|
||||
raisecomOpticalParamHighWarningThresh,
|
||||
raisecomOpticalParamLowAlarmThresh,
|
||||
raisecomOpticalParamLowWarningThresh,
|
||||
raisecomOpticalParamAlarmStatus,
|
||||
raisecomOpticalParamAlarmLastValue,
|
||||
raisecomOpticalParamAlarmLastChange
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of objects that support thresholds on optical
|
||||
parameters and provide status information when the thresholds
|
||||
are exceeded ."
|
||||
::={ raisecomOpticalMonitorMIBGroups 2 }
|
||||
|
||||
raisecomOpticalMIBPMGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
raisecomOpticalMon15MinValidIntervals,
|
||||
raisecomOpticalMon24HrValidIntervals,
|
||||
raisecomOpticalPMCurrentMaxParam,
|
||||
raisecomOpticalPMCurrentMinParam,
|
||||
raisecomOpticalPMCurrentMeanParam,
|
||||
raisecomOpticalPMIntervalMaxParam,
|
||||
raisecomOpticalPMIntervalMinParam,
|
||||
raisecomOpticalPMIntervalMeanParam
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of objects that provide optical performance
|
||||
monitoring data for 15 minute and 24 hour intervals."
|
||||
::={ raisecomOpticalMonitorMIBGroups 3 }
|
||||
|
||||
raisecomOpticalMIBNotifyEnableGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
raisecomOpticalNotifyEnable
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An object to control the generation of notifications."
|
||||
::={ raisecomOpticalMonitorMIBGroups 4 }
|
||||
|
||||
raisecomOpticalMIBNotifGroup NOTIFICATION-GROUP
|
||||
NOTIFICATIONS {
|
||||
raisecomOpticalMonParameterStatus
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A notification generated when a threshold on an optical
|
||||
parameter is exceeded or cleared."
|
||||
::={ raisecomOpticalMonitorMIBGroups 5 }
|
||||
|
||||
END
|
Reference in New Issue