Initial commit
This commit is contained in:
268
MIBS/rs/IRT-TRANSMITTER-SMI-MIB
Normal file
268
MIBS/rs/IRT-TRANSMITTER-SMI-MIB
Normal file
@ -0,0 +1,268 @@
|
||||
--
|
||||
-- IRT-TRANSMITTER-SMI-MIB.my
|
||||
-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
|
||||
-- Thursday, May 03, 2007 at 17:54:59
|
||||
--
|
||||
|
||||
IRT-TRANSMITTER-SMI-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
enterprises, MODULE-IDENTITY
|
||||
FROM SNMPv2-SMI
|
||||
TEXTUAL-CONVENTION
|
||||
FROM SNMPv2-TC;
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.19831
|
||||
irt MODULE-IDENTITY
|
||||
LAST-UPDATED "200705041400Z" -- May 04, 2007 at 14:00 GMT
|
||||
ORGANIZATION
|
||||
"IRT for WORKING-GROUP-TC-MIB"
|
||||
CONTACT-INFO
|
||||
"Contact-info:
|
||||
|
||||
Andreas Metz
|
||||
|
||||
Institut fuer Rundfunktechnik GmbH
|
||||
Broadcast Networks and Servers (SN)
|
||||
|
||||
Floriansmuehlstr.60
|
||||
80939 Munich
|
||||
Germany
|
||||
|
||||
Phone: +49 89 32399 325
|
||||
Fax: +49 89 32399 354
|
||||
"
|
||||
DESCRIPTION
|
||||
"***************************************************
|
||||
Description: IRT-TRANSMITTER-SMI-MIB General structure
|
||||
|
||||
This MIB defines the structure of a SNMP-Agent
|
||||
for all kinds of reserve Transmitters
|
||||
|
||||
PROJECT: TC-MIB - TRANSMITTER-CONTROL-MIB
|
||||
OID: 1.3.6.1.4.1.19831
|
||||
FILE: IRT-TRANSMITTER-SMI-MIB.*
|
||||
AUTHOR: Ludmilla Leidag and Andreas Metz
|
||||
for WORKING-GROUP-TC-MIB
|
||||
|
||||
|
||||
***************************************************"
|
||||
REVISION "200705041400Z" -- May 04, 2007 at 14:00 GMT
|
||||
DESCRIPTION
|
||||
"change LocalRemote
|
||||
add SFNMFN
|
||||
"
|
||||
REVISION "200612201400Z" -- December 20, 2006 at 14:00 GMT
|
||||
DESCRIPTION
|
||||
"Correction"
|
||||
REVISION "200609071400Z" -- September 07, 2006 at 14:00 GMT
|
||||
DESCRIPTION
|
||||
"Relocation of the TC-MIB from the standard OID area at IEC into the private OID area of the IRT "
|
||||
::= { enterprises 19831 }
|
||||
|
||||
|
||||
|
||||
--
|
||||
-- Textual conventions
|
||||
--
|
||||
|
||||
SelectManualAuto ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Description. Auto/Manual selection"
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
undefined(0),
|
||||
manual(1),
|
||||
automatic(2)
|
||||
}
|
||||
|
||||
SelectOnOff ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Description. On/Off selection"
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
undefined(0),
|
||||
on(1),
|
||||
off(2)
|
||||
}
|
||||
|
||||
Input1Input2 ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Description.Input1/Input2"
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
undefined(0),
|
||||
input1(1),
|
||||
input2(2)
|
||||
}
|
||||
|
||||
OkNotOk ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Description.OK/NotOK"
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
undefined(0),
|
||||
ok(1),
|
||||
notok(2)
|
||||
}
|
||||
|
||||
FaultOK ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Description.Fault/OK"
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
undefined(0),
|
||||
fault(1),
|
||||
ok(2)
|
||||
}
|
||||
|
||||
WarningOK ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Description.Warning/OK"
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
undefined(0),
|
||||
warning(1),
|
||||
ok(2)
|
||||
}
|
||||
|
||||
LocalRemote ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Description.Local/Remote"
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
undefined(0),
|
||||
local(1),
|
||||
remote(2)
|
||||
}
|
||||
|
||||
MuteOk ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Description. Mute/OK"
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
undefined(0),
|
||||
mute(1),
|
||||
ok(2)
|
||||
}
|
||||
|
||||
ReadyNotReady ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Description. Ready/Not ready"
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
undefined(0),
|
||||
ready(1),
|
||||
notready(2)
|
||||
}
|
||||
|
||||
ExecutedNotExecuted ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Description. Executed/Not Executed"
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
undefined(0),
|
||||
executed(1),
|
||||
notexecuted(2)
|
||||
}
|
||||
|
||||
PresentNotPresent ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Description. Present/NotPresent"
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
undefined(0),
|
||||
present(1),
|
||||
notpresent(2)
|
||||
}
|
||||
|
||||
SFNMFN ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Description: SFN/MFN Mode"
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
undefined(0),
|
||||
sfn(1),
|
||||
mfn(2)
|
||||
}
|
||||
|
||||
|
||||
--
|
||||
-- Node definitions
|
||||
--
|
||||
|
||||
-- Broadcast
|
||||
-- 1.3.6.1.4.1.19831.1
|
||||
broadcast OBJECT IDENTIFIER ::= { irt 1 }
|
||||
|
||||
|
||||
-- Transmitter
|
||||
-- 1.3.6.1.4.1.19831.1.1
|
||||
transmitter OBJECT IDENTIFIER ::= { broadcast 1 }
|
||||
|
||||
|
||||
-- Digital videobroadcast terrestrial
|
||||
-- 1.3.6.1.4.1.19831.1.1.1
|
||||
dvbT OBJECT IDENTIFIER ::= { transmitter 1 }
|
||||
-- List of assigned devices
|
||||
--
|
||||
-- dvbSingleTransmitter OBJECT IDENTIFIER ::= { dvbT 1 }
|
||||
-- dvbActiveReserve OBJECT IDENTIFIER ::= { dvbT 2 }
|
||||
-- dvbPassiveReserve OBJECT IDENTIFIER ::= { dvbT 3 }
|
||||
-- dvbDualDrive OBJECT IDENTIFIER ::= { dvbT 4 }
|
||||
-- dvbnPlus1 OBJECT IDENTIFIER ::= { dvbT 5 }
|
||||
-- dvbCommon OBJECT IDENTIFIER ::= { dvbT 255 }
|
||||
|
||||
-- Digital audiobroadcast
|
||||
-- 1.3.6.1.4.1.19831.1.1.2
|
||||
dab OBJECT IDENTIFIER ::= { transmitter 2 }
|
||||
-- List of assigned devices
|
||||
--
|
||||
-- dabSingleTransmitter OBJECT IDENTIFIER ::= { dab 1 }
|
||||
-- dabActiveReserve OBJECT IDENTIFIER ::= { dab 2 }
|
||||
-- dabPassiveReserve OBJECT IDENTIFIER ::= { dab 3 }
|
||||
-- dabDualDrive OBJECT IDENTIFIER ::= { dab 4 }
|
||||
-- dabnPlus1 OBJECT IDENTIFIER ::= { dab 5 }
|
||||
-- dabCommon OBJECT IDENTIFIER ::= { dab 255 }
|
||||
|
||||
-- FM transmitters
|
||||
-- 1.3.6.1.4.1.19831.1.1.3
|
||||
fm OBJECT IDENTIFIER ::= { transmitter 3 }
|
||||
-- List of assigned devices
|
||||
--
|
||||
-- fmSingleTransmitter OBJECT IDENTIFIER ::= { fm 1 }
|
||||
-- fmActiveReserve OBJECT IDENTIFIER ::= { fm 2 }
|
||||
-- fmPassiveReserve OBJECT IDENTIFIER ::= { fm 3 }
|
||||
-- fmDualDrive OBJECT IDENTIFIER ::= { fm 4 }
|
||||
-- fmnPlus1 OBJECT IDENTIFIER ::= { fm 5 }
|
||||
-- fmCommon OBJECT IDENTIFIER ::= { fm 255 }
|
||||
|
||||
-- Digital radio mondiale
|
||||
-- 1.3.6.1.4.1.19831.1.1.4
|
||||
drm OBJECT IDENTIFIER ::= { transmitter 4 }
|
||||
|
||||
|
||||
-- Common values for all transmittertypes
|
||||
-- 1.3.6.1.4.1.19831.1.1.7
|
||||
common OBJECT IDENTIFIER ::= { transmitter 7 }
|
||||
-- Common values used by all transmittertypes (eg special Varbinds)
|
||||
|
||||
|
||||
END
|
||||
|
||||
--
|
||||
-- IRT-TRANSMITTER-SMI-MIB.my
|
||||
--
|
Reference in New Issue
Block a user