--* SAGEM SA *
|
||||
--*******************************************************************
|
||||
--*******************************************************************
|
||||
|
||||
-- Filename: shelf
|
||||
-- File type: .mib
|
||||
--
|
||||
-- Description: SNMPc source Mib file.
|
||||
-- The MIB module defines structure for ADR equipement family
|
||||
--
|
||||
-- Version: 19 11 2002
|
||||
--
|
||||
-- Date(DD MM YYYY): 15 11 02 last update for IONOS NMS
|
||||
--
|
||||
-- Contact: D. Mobuchon, F. Bonnevialle
|
||||
--
|
||||
-- History:
|
||||
-- Version: MIB-P0-301199 Date: 30 11 1999
|
||||
--
|
||||
-- Name: F.Bonnevialle
|
||||
-- Date: 12 12 2000
|
||||
-- Desc: original
|
||||
--
|
||||
-- Name: S.LAURENT
|
||||
-- Date: 08 02 2001
|
||||
-- Desc: * Change the MIB number: {Sagem 25} -> {Sagem 150}
|
||||
-- * Add 7 equipment modification counters
|
||||
-- * Add a specific index to the table "laserTable"
|
||||
-- * Remove the configAction Object
|
||||
--
|
||||
-- Name: S.LAURENT
|
||||
-- Date: 18 04 2001
|
||||
-- Desc: * Move the 7 equipment modification counters in the Equip Mib
|
||||
--
|
||||
-- Name: S.LAURENT
|
||||
-- Date: 01 06 2001
|
||||
-- Desc: * Replace the BoardIndex Type by INTEGER and BoardFamily Type by a DisplayString.
|
||||
-- * Add slotName object in the BoardTable
|
||||
-- These modifications allow the MIB to be more independent of the equipment.
|
||||
--
|
||||
-- Name: F.Bonnevialle
|
||||
-- Date: 15 11 2002
|
||||
-- Desc: Modification for SilverCreek Compiler
|
||||
--
|
||||
--*******************************************************************
|
||||
--*******************************************************************
|
||||
--* Copyright (c) 2002, SAGEM , All rights reserved. *
|
||||
--*******************************************************************
|
||||
|
||||
|
||||
SHELF-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
sagemDr FROM SAGEM-DR-MIB
|
||||
SagemBoolean, Severity FROM EQUIPMENT-MIB
|
||||
MODULE-IDENTITY,OBJECT-TYPE,
|
||||
Counter32 FROM SNMPv2-SMI
|
||||
DisplayString FROM SNMPv2-TC;
|
||||
--spiIndex FROM SDH-ETS-MIB;
|
||||
|
||||
|
||||
shelf MODULE-IDENTITY
|
||||
LAST-UPDATED "0012060000Z"
|
||||
ORGANIZATION "SAGEM-Tolbiac drd/ddp/tmhd"
|
||||
CONTACT-INFO
|
||||
""
|
||||
DESCRIPTION
|
||||
"The MIB module specific for ADR equipment"
|
||||
::= { sagemDr 150 }
|
||||
|
||||
-- led
|
||||
led OBJECT IDENTIFIER ::= { shelf 2 }
|
||||
|
||||
-- hold Time
|
||||
holdTime OBJECT IDENTIFIER ::= { shelf 3 }
|
||||
|
||||
-- slot and board
|
||||
board OBJECT IDENTIFIER ::= { shelf 20 }
|
||||
|
||||
-- board table
|
||||
boardList OBJECT IDENTIFIER ::= { shelf 30 }
|
||||
|
||||
-- Software inventory
|
||||
softInv OBJECT IDENTIFIER ::= { shelf 40 }
|
||||
|
||||
-- Harware inventory
|
||||
hardInv OBJECT IDENTIFIER ::= { shelf 50 }
|
||||
|
||||
-- laser data
|
||||
laser OBJECT IDENTIFIER ::= { shelf 100 }
|
||||
|
||||
-- engineering order wire
|
||||
eow OBJECT IDENTIFIER ::= { shelf 120 }
|
||||
|
||||
|
||||
|
||||
--*******************************************************************
|
||||
--* Slot and Board
|
||||
--*******************************************************************
|
||||
boardNumber OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Number of board in equipment."
|
||||
::= { board 1 }
|
||||
|
||||
boardTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF BoardEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"List of board in equipment."
|
||||
::= { board 2 }
|
||||
|
||||
boardEntry OBJECT-TYPE
|
||||
SYNTAX BoardEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A particular board of the equipment."
|
||||
INDEX { boardIndex }
|
||||
::= { boardTable 1 }
|
||||
|
||||
|
||||
ProtectionType ::= INTEGER
|
||||
{
|
||||
none(0),
|
||||
cardp(1)
|
||||
}
|
||||
|
||||
BoardFailure ::= INTEGER
|
||||
{
|
||||
none(0),
|
||||
missing(1),
|
||||
mismatch(2),
|
||||
defective(3)
|
||||
}
|
||||
|
||||
BoardEntry ::= SEQUENCE
|
||||
{
|
||||
boardIndex INTEGER,
|
||||
boardSlotName DisplayString,
|
||||
boardExpectType INTEGER, -- 0 or boardListIndex
|
||||
boardInsertType INTEGER, -- 0 or boardListIndex
|
||||
boardExpectFamily DisplayString,
|
||||
boardInsertFamily DisplayString,
|
||||
boardActive SagemBoolean,
|
||||
boardFirstPortIndex INTEGER,
|
||||
boardProtectionType ProtectionType,
|
||||
boardMonitor SagemBoolean,
|
||||
boardFailure BoardFailure,
|
||||
boardSeverity Severity,
|
||||
boardMissingSev Severity,
|
||||
boardMismatchSev Severity,
|
||||
boardDefectiveSev Severity
|
||||
}
|
||||
|
||||
boardIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A unique value which identify a particular slot.
|
||||
The value of index is a constant assigned to an entry at
|
||||
equipment design time. It is usualy related to hardware.
|
||||
Each equipment maintain its own pool of values:
|
||||
ex ADR155c : A = 1, B = 2, ... M = 5, Fan = 6
|
||||
ex ADR2500c: Fan = 1, PSU1 = 2, ...Trib1 = 8, Trib6= 13, Line1 = 14,...
|
||||
Switch2 = 17, Shelf = 18"
|
||||
::= { boardEntry 1 }
|
||||
|
||||
boardSlotName OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A DisplayString which identify the name of a particular slot.
|
||||
Its value is fixed at equipment design time.
|
||||
It is usualy related to hardware
|
||||
ex ADR155c : A, B, ... Fan
|
||||
ex ADR2500c: Fan, CCU, CTRL, PSU1, ... TRIB5, .... SWITCH1, ..."
|
||||
::= { boardEntry 2 }
|
||||
|
||||
boardExpectType OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A value which configure the expected type. If used, this one must be
|
||||
equal to one of existent boardListIndex for the considerated board. Otherwise,
|
||||
the value is set to 0.
|
||||
Known types are readable in boardListTable
|
||||
"
|
||||
::= { boardEntry 3 }
|
||||
|
||||
boardInsertType OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"When the inserted board doesn't match with the expexted board
|
||||
the boardMismatch failure is generated.
|
||||
The type of the card could be found in hardware inventory."
|
||||
::= { boardEntry 4 }
|
||||
|
||||
boardExpectFamily OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Board Family corresponding to the specified expected kind. This value is send by the equipment.
|
||||
ex ADR155c :
|
||||
ex ADR2500c : CTRL, FAN, AUX, CCU, PSU, STM1 OPT, STM1 ERE, STM4 OPT, STM16 OPT, GBETH, SWITCH
|
||||
"
|
||||
::= { boardEntry 5 }
|
||||
|
||||
boardInsertFamily OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Board Family corresponding to the type of inserted board.
|
||||
ex ADR155c :
|
||||
ex ADR2500c : CTRL, FAN, AUX, CCU, PSU, STM1 OPT, STM1 ERE, STM4 OPT, STM16 OPT, GBETH, SWITCH
|
||||
"
|
||||
::= { boardEntry 6 }
|
||||
|
||||
boardActive OBJECT-TYPE
|
||||
SYNTAX SagemBoolean
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"When the value of this field is set to false, the transmission of
|
||||
this board stop and the board could properly be extracted"
|
||||
::= { boardEntry 7 }
|
||||
|
||||
boardFirstPortIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"If the card is a card with physical ports, then the value is
|
||||
the first index of a physical interface (SPI, PPI) in the mib
|
||||
SDH-ETS. Else, the value is 0."
|
||||
::= { boardEntry 8 }
|
||||
|
||||
boardProtectionType OBJECT-TYPE
|
||||
SYNTAX ProtectionType
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The value of this field indicates the kind of wanted card protection.
|
||||
The default value is NONE.
|
||||
if value is changed in cardP(1)then an entry is created in cardpTable. But this table
|
||||
has to be completed (by setting the cardpReliefIndex,...) to obtain a configured protection.
|
||||
if value is changed in None(0)then the associated entry in cardpTable is deleted.
|
||||
Some cards don't accept any protection. In that case, the value of this field will remain to NONE"
|
||||
::= { boardEntry 9 }
|
||||
|
||||
boardMonitor OBJECT-TYPE
|
||||
SYNTAX SagemBoolean
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"When the value of this field is set to false, the failure detection
|
||||
is stopped for this board."
|
||||
::= { boardEntry 10 }
|
||||
|
||||
boardFailure OBJECT-TYPE
|
||||
SYNTAX BoardFailure
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Active failures on board"
|
||||
::= { boardEntry 11 }
|
||||
|
||||
boardSeverity OBJECT-TYPE
|
||||
SYNTAX Severity
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A reference to failure severity for boards."
|
||||
::= { boardEntry 12 }
|
||||
|
||||
|
||||
boardMissingSev OBJECT-TYPE
|
||||
SYNTAX Severity
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A reference to failure severity for boards."
|
||||
::= { boardEntry 13 }
|
||||
|
||||
boardMismatchSev OBJECT-TYPE
|
||||
SYNTAX Severity
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A reference to failure severity for boards."
|
||||
::= { boardEntry 14 }
|
||||
|
||||
boardDefectiveSev OBJECT-TYPE
|
||||
SYNTAX Severity
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A reference to failure severity for boards."
|
||||
::= { boardEntry 15 }
|
||||
|
||||
--*******************************************************************
|
||||
--* board list
|
||||
--*******************************************************************
|
||||
boardListNumber OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Number of entry of the boardList Table"
|
||||
::= { boardList 1 }
|
||||
|
||||
boardListTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF BoardlistEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"List of board type able to be managed by this equipment .
|
||||
In order to manage a new type, just insert the board and if
|
||||
the family match with a known family, this table will be
|
||||
expand automaticaly with the new type inserted
|
||||
|
||||
The XX fist value defined ( with boardSlotName = Shelf = 18 for ADR2500c)
|
||||
is a list all possible type of boardInsertedType.
|
||||
"
|
||||
::= { boardList 2 }
|
||||
|
||||
boardListEntry OBJECT-TYPE
|
||||
SYNTAX BoardlistEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A particular boardList of the equipment."
|
||||
INDEX { boardListIndex }
|
||||
::= { boardListTable 1 }
|
||||
|
||||
BoardlistEntry ::= SEQUENCE
|
||||
{
|
||||
boardListIndex INTEGER,
|
||||
boardListSlot INTEGER,
|
||||
boardListType DisplayString
|
||||
}
|
||||
|
||||
boardListIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A unique value."
|
||||
::= { boardListEntry 1 }
|
||||
|
||||
boardListSlot OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A reference to the corresponding Slot."
|
||||
::= { boardListEntry 2 }
|
||||
|
||||
boardListType OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"In order to manage a new type, just insert the board and if
|
||||
the family match with a known family, this table will be
|
||||
expand automaticaly with the new type inserted.
|
||||
ex ADR155c :
|
||||
ex ADR2500c: 4S1.1, S4.1, L16.2, SWITCH, ..."
|
||||
::= { boardListEntry 3 }
|
||||
|
||||
|
||||
--*******************************************************************
|
||||
--* Software inventory
|
||||
--*******************************************************************
|
||||
|
||||
softInventoryNumber OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Number of entry of the softInventory Table"
|
||||
::= { softInv 1 }
|
||||
|
||||
softInventoryTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF SoftInventoryEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"List of software inventory used "
|
||||
::= { softInv 2 }
|
||||
|
||||
softInventoryEntry OBJECT-TYPE
|
||||
SYNTAX SoftInventoryEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A particular boardList of the equipment."
|
||||
INDEX { softInventoryIndex }
|
||||
::= { softInventoryTable 1 }
|
||||
|
||||
SoftInventoryEntry ::= SEQUENCE
|
||||
{
|
||||
softInventoryIndex INTEGER,
|
||||
softInventoryBoard INTEGER, -- boardIndex
|
||||
softInventoryType DisplayString,
|
||||
softInventoryCode DisplayString,
|
||||
softInventoryExt DisplayString
|
||||
}
|
||||
|
||||
softInventoryIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A unique value."
|
||||
::= { softInventoryEntry 1 }
|
||||
|
||||
softInventoryBoard OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A reference to the corresponding Slot. This variable is needed because some
|
||||
boards have their owns Applicative and Boot codes. "
|
||||
::= { softInventoryEntry 2 }
|
||||
|
||||
softInventoryType OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indication of type software"
|
||||
::= { softInventoryEntry 3 }
|
||||
|
||||
softInventoryCode OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indication of version code"
|
||||
::= { softInventoryEntry 4 }
|
||||
|
||||
softInventoryExt OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indication of extension code. This one is not mandatory."
|
||||
::= { softInventoryEntry 5 }
|
||||
|
||||
|
||||
|
||||
--*******************************************************************
|
||||
--* Hardware inventory
|
||||
--*******************************************************************
|
||||
|
||||
hardInventoryNumber OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Number of different hardware inventory in equipment."
|
||||
::= { hardInv 1 }
|
||||
|
||||
hardInventoryTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF HardInventoryEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"List of hardware inventory in equipment.
|
||||
A hardware inventory is a description associed to a
|
||||
particular card"
|
||||
::= { hardInv 2 }
|
||||
|
||||
hardInventoryEntry OBJECT-TYPE
|
||||
SYNTAX HardInventoryEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A particular tInv of the equipment."
|
||||
INDEX { hardInventoryIndex }
|
||||
::= { hardInventoryTable 1 }
|
||||
|
||||
HardInventoryEntry ::= SEQUENCE {
|
||||
hardInventoryIndex INTEGER, -- boardIndex
|
||||
hardInventoryBoard DisplayString,
|
||||
hardInventoryDescr DisplayString
|
||||
}
|
||||
|
||||
hardInventoryIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Index of the inventory entry that corresponds to a particular slot"
|
||||
::= { hardInventoryEntry 1 }
|
||||
|
||||
hardInventoryBoard OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Family of card inserted in the slot"
|
||||
::= { hardInventoryEntry 2 }
|
||||
|
||||
hardInventoryDescr OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The content of the inventory: a textual description"
|
||||
::= { hardInventoryEntry 3 }
|
||||
|
||||
--*******************************************************************
|
||||
--* laser
|
||||
--*******************************************************************
|
||||
laserNumber OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Number of optical interface in equipment."
|
||||
::= { laser 1 }
|
||||
|
||||
laserTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF LaserEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"List of synchronous physical interface in equipment."
|
||||
::= { laser 2 }
|
||||
|
||||
laserEntry OBJECT-TYPE
|
||||
SYNTAX LaserEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A particular synchronous physical interface of the equipment."
|
||||
-- INDEX { spiIndex }
|
||||
INDEX { laserIndex }
|
||||
|
||||
::= { laserTable 1 }
|
||||
|
||||
LaserEntry ::= SEQUENCE
|
||||
{
|
||||
-- spiIndex INTEGER,
|
||||
laserIndex INTEGER, -- =spiIndex
|
||||
laserTxEnable SagemBoolean,
|
||||
laserALSEnable SagemBoolean,
|
||||
laserALSRestart2s SagemBoolean,
|
||||
laserALSRestart90s SagemBoolean
|
||||
}
|
||||
|
||||
laserIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" "
|
||||
::= { laserEntry 1 }
|
||||
|
||||
laserTxEnable OBJECT-TYPE
|
||||
SYNTAX SagemBoolean
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enable(true) or disable(false) the laser output of the interface."
|
||||
::= { laserEntry 2 }
|
||||
|
||||
laserALSEnable OBJECT-TYPE
|
||||
SYNTAX SagemBoolean
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Automatic Laser Shutdown enable(true) or disable(false).
|
||||
When enabled, this function cuts the laser output when a los is
|
||||
detected on input signal."
|
||||
::= { laserEntry 3 }
|
||||
|
||||
laserALSRestart2s OBJECT-TYPE
|
||||
SYNTAX SagemBoolean
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Operator command to start a one shot emission during 2s."
|
||||
::= { laserEntry 4 }
|
||||
|
||||
laserALSRestart90s OBJECT-TYPE
|
||||
SYNTAX SagemBoolean
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Operator command to start a one shot emission during 90s."
|
||||
::= { laserEntry 5 }
|
||||
-- end laser data
|
||||
|
||||
|
||||
--*******************************************************************
|
||||
--* Shelf
|
||||
--*******************************************************************
|
||||
adrHotReset OBJECT-TYPE
|
||||
SYNTAX SagemBoolean
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Software hot reset when this variable is set to TRUE"
|
||||
::= { shelf 1 }
|
||||
|
||||
--*******************************************************************
|
||||
--* led
|
||||
--*******************************************************************
|
||||
LedStatus ::= INTEGER
|
||||
{
|
||||
unknown (1),
|
||||
green (2),
|
||||
yellow (3),
|
||||
orange (4),
|
||||
red (5)
|
||||
}
|
||||
|
||||
LedType ::= INTEGER
|
||||
{
|
||||
status1(1),
|
||||
status2(2),
|
||||
online (3),
|
||||
traffic(4),
|
||||
major (5),
|
||||
minor (6),
|
||||
ether (7),
|
||||
halfFull (8)
|
||||
}
|
||||
|
||||
ledNumber OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Number of led in equipment."
|
||||
::= { led 1 }
|
||||
|
||||
ledTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF LedEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"List of led in equipment."
|
||||
::= { led 2 }
|
||||
|
||||
ledEntry OBJECT-TYPE
|
||||
SYNTAX LedEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A particular led of the equipment."
|
||||
INDEX { ledIndex }
|
||||
::= { ledTable 1 }
|
||||
|
||||
LedEntry ::= SEQUENCE
|
||||
{
|
||||
ledIndex INTEGER,
|
||||
ledPosition INTEGER, -- boardIndex
|
||||
ledType LedType,
|
||||
ledStatus LedStatus
|
||||
}
|
||||
|
||||
ledIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A unique value which identify a particular led."
|
||||
::= { ledEntry 1 }
|
||||
|
||||
ledPosition OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A reference to the associated Board on the equipment."
|
||||
::= { ledEntry 2 }
|
||||
|
||||
ledType OBJECT-TYPE
|
||||
SYNTAX LedType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Type of the Led."
|
||||
::= { ledEntry 3 }
|
||||
|
||||
ledStatus OBJECT-TYPE
|
||||
SYNTAX LedStatus
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Status of this Led."
|
||||
::= { ledEntry 4 }
|
||||
|
||||
--*******************************************************************
|
||||
--* hold time
|
||||
--*******************************************************************
|
||||
HoldTime ::= INTEGER
|
||||
{
|
||||
hold01sec(1),
|
||||
hold03sec(3),
|
||||
hold10sec(10),
|
||||
hold30sec(30)
|
||||
}
|
||||
|
||||
adrFailHoldOffTime OBJECT-TYPE
|
||||
SYNTAX HoldTime
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Failure hold off time : the time interval during which the
|
||||
defect is present and the failure is not raised"
|
||||
::= { holdTime 1 }
|
||||
|
||||
adrFailHoldOnTime OBJECT-TYPE
|
||||
SYNTAX HoldTime
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Failure hold on time : the time interval during which the
|
||||
defect is cleared and the failure is not"
|
||||
::= { holdTime 2 }
|
||||
|
||||
|
||||
|
||||
--*******************************************************************
|
||||
--* EOW
|
||||
--*******************************************************************
|
||||
EOWClockMode ::= INTEGER
|
||||
{
|
||||
codirectionnal (0),
|
||||
contradirSlave(1),
|
||||
contradirMaster(2)
|
||||
}
|
||||
|
||||
EOWType ::= INTEGER
|
||||
{
|
||||
rsE1 (1),
|
||||
rsF1 (2),
|
||||
rsOther(3),
|
||||
msE2 (4),
|
||||
aux (5)
|
||||
}
|
||||
|
||||
eowNumber OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Number of EOW port in equipment."
|
||||
::= {eow 1 }
|
||||
|
||||
eowTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF EowEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"List of EOW port in equipment."
|
||||
::= { eow 2 }
|
||||
|
||||
eowEntry OBJECT-TYPE
|
||||
SYNTAX EowEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A particular EOW port of the equipment."
|
||||
INDEX { eowIndex }
|
||||
::= { eowTable 1 }
|
||||
|
||||
|
||||
EowEntry ::= SEQUENCE
|
||||
{
|
||||
eowIndex INTEGER,
|
||||
eowName DisplayString,
|
||||
eowSrcType EOWType,
|
||||
eowSrcPtr INTEGER,
|
||||
eowSinkType EOWType,
|
||||
eowSinkPtr INTEGER,
|
||||
eowClockMode EOWClockMode
|
||||
}
|
||||
|
||||
|
||||
eowIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A unique value which identify a particular
|
||||
EOW port.
|
||||
The value of index is a constant assigned to an entry at
|
||||
equipment design time. It is usualy related to harware."
|
||||
::= { eowEntry 1 }
|
||||
|
||||
eowName OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A text string which identifies the particular entry among the
|
||||
EOW port entries. "
|
||||
::= { eowEntry 2 }
|
||||
|
||||
eowSrcType OBJECT-TYPE
|
||||
SYNTAX EOWType
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A reference to the object which sends the data flow to this
|
||||
interface. Usually the value is the oid of a vc12 or a connection."
|
||||
::= { eowEntry 6 }
|
||||
|
||||
eowSrcPtr OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A reference to the object which sends the data flow to this
|
||||
interface. Usually the value is the oid of a vc12 or a connection."
|
||||
::= { eowEntry 7 }
|
||||
|
||||
eowSinkType OBJECT-TYPE
|
||||
SYNTAX EOWType
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A reference to the object which sends the data flow to this
|
||||
interface. Usually the value is the oid of a vc12 or a connection."
|
||||
::= { eowEntry 8 }
|
||||
|
||||
eowSinkPtr OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A reference to the object which sends the data flow to this
|
||||
interface. Usually the value is the oid of a vc12 or a connection."
|
||||
::= { eowEntry 9 }
|
||||
|
||||
eowClockMode OBJECT-TYPE
|
||||
SYNTAX EOWClockMode
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Select the direction of the two external synchronisation lines."
|
||||
::= { eowEntry 10 }
|
||||
|
||||
END
|