Initial commit
This commit is contained in:
		
							
								
								
									
										439
									
								
								MIBS/sagemcom/XCONNECTION-MIB
									
									
									
									
									
										Normal file
									
								
							
							
						
						
									
										439
									
								
								MIBS/sagemcom/XCONNECTION-MIB
									
									
									
									
									
										Normal file
									
								
							@@ -0,0 +1,439 @@
 | 
			
		||||
--*******************************************************************
 | 
			
		||||
--*    SAGEM SA			 							  				*
 | 
			
		||||
--*******************************************************************
 | 
			
		||||
--*******************************************************************
 | 
			
		||||
 | 
			
		||||
--  Filename: connection
 | 
			
		||||
--  File type: .mib    
 | 
			
		||||
-- 
 | 
			
		||||
--  Description:	SNMPc source Mib file.         
 | 
			
		||||
--
 | 
			
		||||
--  Version:  19 11 2002
 | 
			
		||||
--	
 | 
			
		||||
--  Date(DD MM YYYY): 15 11 02 last update for IONOS NMS 
 | 
			
		||||
--     
 | 
			
		||||
--  Contact: D. Mobuchon, F. Bonnevialle
 | 
			
		||||
--
 | 
			
		||||
--  History: 
 | 
			
		||||
--		Name: F.Bonnevialle	
 | 
			
		||||
--		Date: 12 12 2000 
 | 
			
		||||
--		Desc: original
 | 
			
		||||
--
 | 
			
		||||
--		Name: S.LAURENT	
 | 
			
		||||
--		Date: 22 02 2001 
 | 
			
		||||
--		Desc:   * Access right Modifications (from "Read-write" to "Read-Only") of some
 | 
			
		||||
--          LinkTable variables .   
 | 
			
		||||
--          Use the Xcon vector to add or delete TableLink elements.
 | 
			
		||||
--  			* Modification of the LinkDirection enum in order to 
 | 
			
		||||
--         	match up its values with those of the ADR equipment.
 | 
			
		||||
--				* Modification of Xcon vector in order to add the new variable xconAction,
 | 
			
		||||
--			which indicates the kind of the action (Creation(1) or Deletion(2))  
 | 
			
		||||
--				* The linkImplementation variable, which should allow to reserve a 
 | 
			
		||||
--          connection without physical implementation, is maintained (for a next use)
 | 
			
		||||
--          but is not implemented in the SNMP Agent (its value is always set to TRUE)
 | 
			
		||||
--   			* The 6 subelements of the name of the connexion have been replaced by
 | 
			
		||||
--   		a unique variable: xconName (which matches to M1400 format)
 | 
			
		||||
-- 
 | 
			
		||||
--		Name: S.LAURENT	
 | 
			
		||||
--		Date: 19 04 2001 
 | 
			
		||||
--		Desc:   * Modification of the CTPType values 
 | 
			
		||||
--
 | 
			
		||||
--		Name: S.LAURENT	
 | 
			
		||||
--		Date: 25 04 2001 
 | 
			
		||||
--		Desc:   * Change the MIB number: {Sagem 120} -> {Sagem 108}
 | 
			
		||||
--
 | 
			
		||||
--		Name: S.LAURENT	
 | 
			
		||||
--		Date: 10 08 2001 
 | 
			
		||||
--		Desc:   * LinkImplementation Access right Modification
 | 
			
		||||
--				 (from "Read-Only" to "Read-Write")
 | 
			
		||||
--
 | 
			
		||||
--		Name: S.LAURENT	
 | 
			
		||||
--		Date: 22 05 2002 
 | 
			
		||||
--		Desc:   * Add a new CTPType Value: nspi(100)
 | 
			
		||||
--    
 | 
			
		||||
--		Name: F.Bonnevialle 	
 | 
			
		||||
--		Date: 15 11 2002 		
 | 
			
		||||
--		Desc: Modification for SilverCreek Compiler
 | 
			
		||||
--			 
 | 
			
		||||
--*******************************************************************
 | 
			
		||||
--*******************************************************************
 | 
			
		||||
--*   Copyright (c) 2002, SAGEM , All rights reserved.              *
 | 
			
		||||
--*******************************************************************
 | 
			
		||||
                                                                     
 | 
			
		||||
                                                                     
 | 
			
		||||
--*******************************************************************
 | 
			
		||||
-- MIB: XCONNECTION-MIB
 | 
			
		||||
--*******************************************************************
 | 
			
		||||
XCONNECTION-MIB DEFINITIONS ::= BEGIN
 | 
			
		||||
 | 
			
		||||
--*******************************************************************
 | 
			
		||||
-- IMPORTS
 | 
			
		||||
--*******************************************************************
 | 
			
		||||
 | 
			
		||||
   IMPORTS
 | 
			
		||||
   sagemDr								FROM SAGEM-DR-MIB
 | 
			
		||||
   SagemBoolean							FROM EQUIPMENT-MIB
 | 
			
		||||
   MODULE-IDENTITY,OBJECT-TYPE      	FROM SNMPv2-SMI
 | 
			
		||||
   DisplayString                    	FROM SNMPv2-TC; --RFC1213-MIB;
 | 
			
		||||
 | 
			
		||||
 | 
			
		||||
   
 | 
			
		||||
   xconnection	MODULE-IDENTITY
 | 
			
		||||
      LAST-UPDATED "0205220000Z"
 | 
			
		||||
      ORGANIZATION "SAGEM-Tolbiac drd/ddp/tmhd"
 | 
			
		||||
      CONTACT-INFO
 | 
			
		||||
	"    "
 | 
			
		||||
      DESCRIPTION 
 | 
			
		||||
	"The MIB module describes connection in physical layer
 | 
			
		||||
	of transmission equipements such as pdh/sdh mux and cross connect.
 | 
			
		||||
	This mib assumes that terminaison point are provided by other mibs,
 | 
			
		||||
	such as sdh.mib.
 | 
			
		||||
	xconnection is a particular case of SubNetworkConnection defined 
 | 
			
		||||
	in ETS 300 653"
 | 
			
		||||
      ::= { sagemDr 108}
 | 
			
		||||
     
 | 
			
		||||
   -- linkTable
 | 
			
		||||
   link		  	OBJECT IDENTIFIER ::= { xconnection 10 } 
 | 
			
		||||
 | 
			
		||||
   -- create/delete connection
 | 
			
		||||
   xcon			OBJECT IDENTIFIER ::= { xconnection 30 }   
 | 
			
		||||
   
 | 
			
		||||
--*******************************************************************
 | 
			
		||||
-- Link
 | 
			
		||||
--*******************************************************************
 | 
			
		||||
   TrafficStatus ::= INTEGER
 | 
			
		||||
   { 
 | 
			
		||||
   	none(0),             -- Future case of a non-implemented link 
 | 
			
		||||
   	working(1),
 | 
			
		||||
   	protection(2)
 | 
			
		||||
   }       
 | 
			
		||||
   
 | 
			
		||||
   ProtectionType ::= INTEGER
 | 
			
		||||
   { 
 | 
			
		||||
   	none(0),
 | 
			
		||||
   	snc(1)
 | 
			
		||||
   }   
 | 
			
		||||
 | 
			
		||||
   ProtectionStatus ::= INTEGER
 | 
			
		||||
   { 
 | 
			
		||||
   	none(0),
 | 
			
		||||
   	used(1)
 | 
			
		||||
   }   
 | 
			
		||||
   
 | 
			
		||||
   LinkDirection ::= INTEGER 
 | 
			
		||||
   {
 | 
			
		||||
   	unidirectional(1), 
 | 
			
		||||
   	bidirectional(2)
 | 
			
		||||
   }                                        
 | 
			
		||||
   
 | 
			
		||||
   CTPType      ::= INTEGER
 | 
			
		||||
   {          
 | 
			
		||||
   	unknown(0),
 | 
			
		||||
   	au(1),
 | 
			
		||||
   	au4c(2), 
 | 
			
		||||
   	au16c(3),
 | 
			
		||||
   	tu3(10),
 | 
			
		||||
   	tu12(20),
 | 
			
		||||
   	pdh2M (50),
 | 
			
		||||
   	pdh34M (51),
 | 
			
		||||
   	pdh45M (52),
 | 
			
		||||
   	pdh140M (53),
 | 
			
		||||
   	eth10M(60),
 | 
			
		||||
   	eth100M(61),
 | 
			
		||||
   	eth1G(62),
 | 
			
		||||
   	nspi(100)
 | 
			
		||||
   }
 | 
			
		||||
   
 | 
			
		||||
   linkNumber   OBJECT-TYPE
 | 
			
		||||
      SYNTAX       INTEGER(0..2147483647)
 | 
			
		||||
      MAX-ACCESS   read-only
 | 
			
		||||
      STATUS       current
 | 
			
		||||
      DESCRIPTION 
 | 
			
		||||
	"Number of cross connections in equipment."  
 | 
			
		||||
      ::= { link 1 } 
 | 
			
		||||
   
 | 
			
		||||
   linkTable   OBJECT-TYPE
 | 
			
		||||
      SYNTAX       SEQUENCE OF LinkEntry
 | 
			
		||||
      MAX-ACCESS   not-accessible
 | 
			
		||||
      STATUS       current
 | 
			
		||||
      DESCRIPTION 
 | 
			
		||||
	"List of link in equipment. For example, a bidirectionnal 
 | 
			
		||||
    connection is composed of 2 links. A SNC protected bidirectionnal
 | 
			
		||||
    connection is composed of 3 permanent links ."
 | 
			
		||||
      ::= { link 2 } 
 | 
			
		||||
 | 
			
		||||
    linkEntry   OBJECT-TYPE
 | 
			
		||||
      SYNTAX       LinkEntry
 | 
			
		||||
      MAX-ACCESS   not-accessible
 | 
			
		||||
      STATUS       current
 | 
			
		||||
      DESCRIPTION 
 | 
			
		||||
	"A particular synchronous physical interface of the equipment." 
 | 
			
		||||
      INDEX        { linkIndex } 
 | 
			
		||||
      ::= { linkTable 1 } 
 | 
			
		||||
   
 | 
			
		||||
   LinkEntry ::= SEQUENCE 
 | 
			
		||||
   {
 | 
			
		||||
      linkIndex 					INTEGER,
 | 
			
		||||
      linkSinkType					CTPType,
 | 
			
		||||
      linkSrcType					CTPType,
 | 
			
		||||
      linkCTPSink 					INTEGER,
 | 
			
		||||
      linkCTPSource		       		INTEGER,
 | 
			
		||||
      linkName 						DisplayString,
 | 
			
		||||
      linkGroupId            		INTEGER,
 | 
			
		||||
      linkDirection         		LinkDirection,      
 | 
			
		||||
      linkProtectionType		    ProtectionType,
 | 
			
		||||
      linkProtectionStatus			ProtectionStatus,
 | 
			
		||||
      linkTrafficStatus				TrafficStatus,
 | 
			
		||||
      linkImplementation			SagemBoolean
 | 
			
		||||
   }
 | 
			
		||||
   
 | 
			
		||||
   linkIndex OBJECT-TYPE
 | 
			
		||||
      SYNTAX 	   INTEGER(0..2147483647)
 | 
			
		||||
      MAX-ACCESS   read-only
 | 
			
		||||
      STATUS       current
 | 
			
		||||
      DESCRIPTION 
 | 
			
		||||
	"linkIndex = number of the CTP Output
 | 
			
		||||
			   = sncIndex "  
 | 
			
		||||
      ::= { linkEntry 1 } 
 | 
			
		||||
   
 | 
			
		||||
   linkSinkType OBJECT-TYPE
 | 
			
		||||
      SYNTAX 	    CTPType
 | 
			
		||||
      MAX-ACCESS   read-only
 | 
			
		||||
      STATUS       current
 | 
			
		||||
      DESCRIPTION 
 | 
			
		||||
	"Kind of CTP table from which the connection is issued"  
 | 
			
		||||
      ::= { linkEntry 2 }
 | 
			
		||||
   
 | 
			
		||||
   linkSrcType OBJECT-TYPE
 | 
			
		||||
      SYNTAX 	    CTPType
 | 
			
		||||
      MAX-ACCESS   read-only
 | 
			
		||||
      STATUS       current
 | 
			
		||||
      DESCRIPTION 
 | 
			
		||||
	"Kind of CTP table from which the connection is issued"  
 | 
			
		||||
      ::= { linkEntry 3 }
 | 
			
		||||
      
 | 
			
		||||
   linkCTPSink OBJECT-TYPE
 | 
			
		||||
      SYNTAX 	   INTEGER(0..2147483647)
 | 
			
		||||
      MAX-ACCESS   read-only
 | 
			
		||||
      STATUS       current
 | 
			
		||||
      DESCRIPTION 
 | 
			
		||||
	"The value of this field indicates the Ouput 
 | 
			
		||||
	Connection Point  which composes the unidirectionnal 
 | 
			
		||||
	link.It's an index in considerated TTP table
 | 
			
		||||
	linkCTPSink = linkIndex"  
 | 
			
		||||
      ::= { linkEntry 4 } 
 | 
			
		||||
   
 | 
			
		||||
   linkCTPSource   OBJECT-TYPE
 | 
			
		||||
      SYNTAX       INTEGER(0..2147483647)
 | 
			
		||||
      MAX-ACCESS   read-only
 | 
			
		||||
      STATUS       current
 | 
			
		||||
      DESCRIPTION
 | 
			
		||||
   "The value of this field indicates the Input 
 | 
			
		||||
	Connection Point  which composes the unidirectionnal 
 | 
			
		||||
	link. It's an index in considerated TTP table "
 | 
			
		||||
      ::= { linkEntry 5 }
 | 
			
		||||
   
 | 
			
		||||
   linkName        OBJECT-TYPE
 | 
			
		||||
      SYNTAX       DisplayString 
 | 
			
		||||
      MAX-ACCESS   read-write
 | 
			
		||||
      STATUS       current
 | 
			
		||||
      DESCRIPTION 
 | 
			
		||||
	"A text string which identifies the name of this link.
 | 
			
		||||
    Links names of a bidirectionnal link must have different name.
 | 
			
		||||
    Same direction SNC protected links have an identical name.
 | 
			
		||||
    M1400 UIT-T specifies the field's format "
 | 
			
		||||
      ::= { linkEntry 6 }
 | 
			
		||||
 | 
			
		||||
   linkGroupId     OBJECT-TYPE
 | 
			
		||||
      SYNTAX       INTEGER(0..2147483647)
 | 
			
		||||
      MAX-ACCESS   read-write
 | 
			
		||||
      STATUS       current
 | 
			
		||||
      DESCRIPTION
 | 
			
		||||
   "A group identifier is used to group links by community."
 | 
			
		||||
      ::= { linkEntry 7 }
 | 
			
		||||
  
 | 
			
		||||
   linkDirection   OBJECT-TYPE
 | 
			
		||||
      SYNTAX       LinkDirection
 | 
			
		||||
      MAX-ACCESS   read-only
 | 
			
		||||
      STATUS       current
 | 
			
		||||
      DESCRIPTION
 | 
			
		||||
   "Unidirectional or Bidirectionnal connections."
 | 
			
		||||
      ::= { linkEntry 8 }
 | 
			
		||||
   
 | 
			
		||||
   linkProtectionType   OBJECT-TYPE
 | 
			
		||||
      SYNTAX       ProtectionType
 | 
			
		||||
      MAX-ACCESS   read-write
 | 
			
		||||
      STATUS       current
 | 
			
		||||
      DESCRIPTION
 | 
			
		||||
   "The value of this field indicates the kind of wanted link protection.
 | 
			
		||||
    The default value is NONE.
 | 
			
		||||
    if value is changed in Snc(1)then an entry is created in Snc table with the same index. But this table
 | 
			
		||||
    has to be completed (by setting the PIC,...) to obtain a configured protection. 
 | 
			
		||||
    if value is changed in None(0)then the associated entry in Snc table is deleted.
 | 
			
		||||
    When the value is set to Snc for a particular entry of LinkTable, other links which are in relation (of
 | 
			
		||||
    direction or protection) with this main link remain setting to None for this field. But all links are set to the USED(1) value
 | 
			
		||||
    in the next field (linkProtectionStatus)"
 | 
			
		||||
      ::= { linkEntry 9 }
 | 
			
		||||
 | 
			
		||||
  linkProtectionStatus      OBJECT-TYPE
 | 
			
		||||
	  SYNTAX       ProtectionStatus
 | 
			
		||||
	  MAX-ACCESS   read-only
 | 
			
		||||
      STATUS       current
 | 
			
		||||
      DESCRIPTION 
 | 
			
		||||
	"The value of this field indicates if the link is used directly or not in a Snc protection.
 | 
			
		||||
	For a non-protected link, this field is mandatory set to None.
 | 
			
		||||
	The field value particulary allow to know the hability of link deletion."
 | 
			
		||||
      ::= { linkEntry 10 }
 | 
			
		||||
 | 
			
		||||
  linkTrafficStatus      OBJECT-TYPE
 | 
			
		||||
	  SYNTAX       TrafficStatus
 | 
			
		||||
	  MAX-ACCESS   read-only
 | 
			
		||||
      STATUS       current
 | 
			
		||||
      DESCRIPTION 
 | 
			
		||||
	"The value of this field indicates where is the traffic.
 | 
			
		||||
	For a non-protected link, this field is mandatory set to working"
 | 
			
		||||
      ::= { linkEntry 11 }
 | 
			
		||||
  
 | 
			
		||||
  linkImplementation      OBJECT-TYPE
 | 
			
		||||
	  SYNTAX       SagemBoolean
 | 
			
		||||
	  MAX-ACCESS   read-write
 | 
			
		||||
      STATUS       current
 | 
			
		||||
      DESCRIPTION 
 | 
			
		||||
	"Actually, this variable is not implemented (always set to TRUE).
 | 
			
		||||
	 But it could be used to allow to reserve a connection without physical implementation"
 | 
			
		||||
      ::= { linkEntry 12 }     
 | 
			
		||||
     
 | 
			
		||||
     
 | 
			
		||||
      
 | 
			
		||||
    
 | 
			
		||||
--*******************************************************************
 | 
			
		||||
-- xcon : creation/deletion of Xconnection    
 | 
			
		||||
-- This vector has been created to allow to:
 | 
			
		||||
--     * create or delete Xconnection in an atomic way (no need to use Set All command)
 | 
			
		||||
--     * keep critical variable of linkTable (such as linkIndex) in a Read-Only Access 
 | 
			
		||||
--     * get back a special message in case of trouble.
 | 
			
		||||
--*******************************************************************      
 | 
			
		||||
   XconDir ::= INTEGER 
 | 
			
		||||
   {
 | 
			
		||||
   	unknown(0),                     -- Future case of a non-implemented link 
 | 
			
		||||
   	unidirectional(1),
 | 
			
		||||
   	bidirectional(2)
 | 
			
		||||
   }
 | 
			
		||||
 | 
			
		||||
   ActionType ::= INTEGER 
 | 
			
		||||
   {
 | 
			
		||||
   	unknown(0),
 | 
			
		||||
   	creation(1),
 | 
			
		||||
   	deletion(2)
 | 
			
		||||
   }
 | 
			
		||||
 | 
			
		||||
  
 | 
			
		||||
   xconNumber   OBJECT-TYPE
 | 
			
		||||
      SYNTAX       INTEGER(0..2147483647)
 | 
			
		||||
      MAX-ACCESS   read-write
 | 
			
		||||
      STATUS       current
 | 
			
		||||
      DESCRIPTION 
 | 
			
		||||
	"Number of connection to process."  
 | 
			
		||||
      ::= { xcon 1 }
 | 
			
		||||
            
 | 
			
		||||
   xconSinkType   OBJECT-TYPE
 | 
			
		||||
      SYNTAX       CTPType
 | 
			
		||||
      MAX-ACCESS   read-write
 | 
			
		||||
      STATUS       current
 | 
			
		||||
      DESCRIPTION 
 | 
			
		||||
	"Type of CTP"  
 | 
			
		||||
      ::= { xcon 2 } 
 | 
			
		||||
   
 | 
			
		||||
   xconSinkIndex   OBJECT-TYPE
 | 
			
		||||
      SYNTAX       INTEGER(0..2147483647)
 | 
			
		||||
      MAX-ACCESS   read-write
 | 
			
		||||
      STATUS       current
 | 
			
		||||
      DESCRIPTION 
 | 
			
		||||
	"Output CTP"  
 | 
			
		||||
      ::= { xcon 3 } 
 | 
			
		||||
   
 | 
			
		||||
   xconSrcType   OBJECT-TYPE
 | 
			
		||||
      SYNTAX       CTPType
 | 
			
		||||
      MAX-ACCESS   read-write
 | 
			
		||||
      STATUS       current
 | 
			
		||||
      DESCRIPTION 
 | 
			
		||||
	"Type of CTP"  
 | 
			
		||||
      ::= { xcon 4 } 
 | 
			
		||||
   
 | 
			
		||||
   xconSrcIndex   OBJECT-TYPE
 | 
			
		||||
      SYNTAX       INTEGER(0..2147483647)
 | 
			
		||||
      MAX-ACCESS   read-write
 | 
			
		||||
      STATUS       current
 | 
			
		||||
      DESCRIPTION 
 | 
			
		||||
	"Input CTP"  
 | 
			
		||||
      ::= { xcon 5 }  
 | 
			
		||||
 | 
			
		||||
   xconDirection   OBJECT-TYPE
 | 
			
		||||
      SYNTAX       XconDir 
 | 
			
		||||
      MAX-ACCESS   read-write
 | 
			
		||||
      STATUS       current
 | 
			
		||||
      DESCRIPTION
 | 
			
		||||
   "Bidirectionnal connections are composed of two unidirectional xcon
 | 
			
		||||
    and therefore 2 link entries."
 | 
			
		||||
      ::= { xcon 6 }
 | 
			
		||||
      
 | 
			
		||||
   xconName        OBJECT-TYPE
 | 
			
		||||
      SYNTAX       DisplayString 
 | 
			
		||||
      MAX-ACCESS   read-write
 | 
			
		||||
      STATUS       current
 | 
			
		||||
      DESCRIPTION 
 | 
			
		||||
	"A text string which identifies the name of this cross-connection.
 | 
			
		||||
    M1400 UIT-T specifies the field's format like this:
 | 
			
		||||
     	NameTownA/NameSuffixA-NameTownB/NameSuffixB NameFunctionSNameSerial
 | 
			
		||||
     		* NameTownX field accepts alpha-numeric and space characters. 
 | 
			
		||||
     			NameTownB is preceded by a '-' character.
 | 
			
		||||
     			Maximum length is 12 charracters.
 | 
			
		||||
     			Not mandatory fields.
 | 
			
		||||
     		* NameSuffixX field accepts alpha-numeric characters. 
 | 
			
		||||
     		    It's preceded by a '/' character.
 | 
			
		||||
     		    Maximum length is 3 characters.
 | 
			
		||||
     		    Not mandatory fields.
 | 
			
		||||
     		* NameFunction field accepts alpha-numeric characters.
 | 
			
		||||
     		    It's followed by a 'S' character.
 | 
			
		||||
     		    Maximum length is 3 characters.
 | 
			
		||||
     		    Mandatory field.
 | 
			
		||||
     		    It represents the function code.
 | 
			
		||||
     		* NameSerial field accepts 4-figure number.
 | 
			
		||||
     		    Not mandatory field.
 | 
			
		||||
     		    It represents the serial number and will be incremented
 | 
			
		||||
    			automatically from the base serial number provided.
 | 
			
		||||
    For ADR2500 equipments:
 | 
			
		||||
    	Links names of a bidirectionnal link must have different name.
 | 
			
		||||
    	Same direction SNC protected links have an identical name."    		    
 | 
			
		||||
      ::= { xcon 7 }
 | 
			
		||||
 | 
			
		||||
 
 | 
			
		||||
    xconAction   OBJECT-TYPE  
 | 
			
		||||
   	  SYNTAX 		ActionType
 | 
			
		||||
   	  MAX-ACCESS    read-write
 | 
			
		||||
   	  STATUS		current
 | 
			
		||||
   	  DESCRIPTION	
 | 
			
		||||
   	  "Type of action: Unknown(0) or Creation(1) or deletion(2)"
 | 
			
		||||
      ::= { xcon 8 } 
 | 
			
		||||
   	                         
 | 
			
		||||
    xconProceed   OBJECT-TYPE
 | 
			
		||||
      SYNTAX       SagemBoolean
 | 
			
		||||
      MAX-ACCESS   read-write
 | 
			
		||||
      STATUS       current
 | 
			
		||||
      DESCRIPTION 
 | 
			
		||||
	"
 | 
			
		||||
	This entry is use to create (set to `true').
 | 
			
		||||
	The value of the field remains to `true' until creation is 
 | 
			
		||||
	completed or has been aborted. 
 | 
			
		||||
	"  
 | 
			
		||||
      ::= { xcon 20 } 
 | 
			
		||||
   
 | 
			
		||||
   xconDiagnostic   OBJECT-TYPE
 | 
			
		||||
      SYNTAX       DisplayString
 | 
			
		||||
      MAX-ACCESS   read-only
 | 
			
		||||
      STATUS       current
 | 
			
		||||
      DESCRIPTION 
 | 
			
		||||
	"A string used to help in case of trouble."  
 | 
			
		||||
      ::= { xcon 21 }  
 | 
			
		||||
   
 | 
			
		||||
END
 | 
			
		||||
		Reference in New Issue
	