Initial commit
This commit is contained in:
439
MIBS/sagemcom/XCONNECTION-MIB
Normal file
439
MIBS/sagemcom/XCONNECTION-MIB
Normal file
@@ -0,0 +1,439 @@
|
||||
--*******************************************************************
|
||||
--* SAGEM SA *
|
||||
--*******************************************************************
|
||||
--*******************************************************************
|
||||
|
||||
-- Filename: connection
|
||||
-- File type: .mib
|
||||
--
|
||||
-- Description: SNMPc source Mib file.
|
||||
--
|
||||
-- Version: 19 11 2002
|
||||
--
|
||||
-- Date(DD MM YYYY): 15 11 02 last update for IONOS NMS
|
||||
--
|
||||
-- Contact: D. Mobuchon, F. Bonnevialle
|
||||
--
|
||||
-- History:
|
||||
-- Name: F.Bonnevialle
|
||||
-- Date: 12 12 2000
|
||||
-- Desc: original
|
||||
--
|
||||
-- Name: S.LAURENT
|
||||
-- Date: 22 02 2001
|
||||
-- Desc: * Access right Modifications (from "Read-write" to "Read-Only") of some
|
||||
-- LinkTable variables .
|
||||
-- Use the Xcon vector to add or delete TableLink elements.
|
||||
-- * Modification of the LinkDirection enum in order to
|
||||
-- match up its values with those of the ADR equipment.
|
||||
-- * Modification of Xcon vector in order to add the new variable xconAction,
|
||||
-- which indicates the kind of the action (Creation(1) or Deletion(2))
|
||||
-- * The linkImplementation variable, which should allow to reserve a
|
||||
-- connection without physical implementation, is maintained (for a next use)
|
||||
-- but is not implemented in the SNMP Agent (its value is always set to TRUE)
|
||||
-- * The 6 subelements of the name of the connexion have been replaced by
|
||||
-- a unique variable: xconName (which matches to M1400 format)
|
||||
--
|
||||
-- Name: S.LAURENT
|
||||
-- Date: 19 04 2001
|
||||
-- Desc: * Modification of the CTPType values
|
||||
--
|
||||
-- Name: S.LAURENT
|
||||
-- Date: 25 04 2001
|
||||
-- Desc: * Change the MIB number: {Sagem 120} -> {Sagem 108}
|
||||
--
|
||||
-- Name: S.LAURENT
|
||||
-- Date: 10 08 2001
|
||||
-- Desc: * LinkImplementation Access right Modification
|
||||
-- (from "Read-Only" to "Read-Write")
|
||||
--
|
||||
-- Name: S.LAURENT
|
||||
-- Date: 22 05 2002
|
||||
-- Desc: * Add a new CTPType Value: nspi(100)
|
||||
--
|
||||
-- Name: F.Bonnevialle
|
||||
-- Date: 15 11 2002
|
||||
-- Desc: Modification for SilverCreek Compiler
|
||||
--
|
||||
--*******************************************************************
|
||||
--*******************************************************************
|
||||
--* Copyright (c) 2002, SAGEM , All rights reserved. *
|
||||
--*******************************************************************
|
||||
|
||||
|
||||
--*******************************************************************
|
||||
-- MIB: XCONNECTION-MIB
|
||||
--*******************************************************************
|
||||
XCONNECTION-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
--*******************************************************************
|
||||
-- IMPORTS
|
||||
--*******************************************************************
|
||||
|
||||
IMPORTS
|
||||
sagemDr FROM SAGEM-DR-MIB
|
||||
SagemBoolean FROM EQUIPMENT-MIB
|
||||
MODULE-IDENTITY,OBJECT-TYPE FROM SNMPv2-SMI
|
||||
DisplayString FROM SNMPv2-TC; --RFC1213-MIB;
|
||||
|
||||
|
||||
|
||||
xconnection MODULE-IDENTITY
|
||||
LAST-UPDATED "0205220000Z"
|
||||
ORGANIZATION "SAGEM-Tolbiac drd/ddp/tmhd"
|
||||
CONTACT-INFO
|
||||
" "
|
||||
DESCRIPTION
|
||||
"The MIB module describes connection in physical layer
|
||||
of transmission equipements such as pdh/sdh mux and cross connect.
|
||||
This mib assumes that terminaison point are provided by other mibs,
|
||||
such as sdh.mib.
|
||||
xconnection is a particular case of SubNetworkConnection defined
|
||||
in ETS 300 653"
|
||||
::= { sagemDr 108}
|
||||
|
||||
-- linkTable
|
||||
link OBJECT IDENTIFIER ::= { xconnection 10 }
|
||||
|
||||
-- create/delete connection
|
||||
xcon OBJECT IDENTIFIER ::= { xconnection 30 }
|
||||
|
||||
--*******************************************************************
|
||||
-- Link
|
||||
--*******************************************************************
|
||||
TrafficStatus ::= INTEGER
|
||||
{
|
||||
none(0), -- Future case of a non-implemented link
|
||||
working(1),
|
||||
protection(2)
|
||||
}
|
||||
|
||||
ProtectionType ::= INTEGER
|
||||
{
|
||||
none(0),
|
||||
snc(1)
|
||||
}
|
||||
|
||||
ProtectionStatus ::= INTEGER
|
||||
{
|
||||
none(0),
|
||||
used(1)
|
||||
}
|
||||
|
||||
LinkDirection ::= INTEGER
|
||||
{
|
||||
unidirectional(1),
|
||||
bidirectional(2)
|
||||
}
|
||||
|
||||
CTPType ::= INTEGER
|
||||
{
|
||||
unknown(0),
|
||||
au(1),
|
||||
au4c(2),
|
||||
au16c(3),
|
||||
tu3(10),
|
||||
tu12(20),
|
||||
pdh2M (50),
|
||||
pdh34M (51),
|
||||
pdh45M (52),
|
||||
pdh140M (53),
|
||||
eth10M(60),
|
||||
eth100M(61),
|
||||
eth1G(62),
|
||||
nspi(100)
|
||||
}
|
||||
|
||||
linkNumber OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Number of cross connections in equipment."
|
||||
::= { link 1 }
|
||||
|
||||
linkTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF LinkEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"List of link in equipment. For example, a bidirectionnal
|
||||
connection is composed of 2 links. A SNC protected bidirectionnal
|
||||
connection is composed of 3 permanent links ."
|
||||
::= { link 2 }
|
||||
|
||||
linkEntry OBJECT-TYPE
|
||||
SYNTAX LinkEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A particular synchronous physical interface of the equipment."
|
||||
INDEX { linkIndex }
|
||||
::= { linkTable 1 }
|
||||
|
||||
LinkEntry ::= SEQUENCE
|
||||
{
|
||||
linkIndex INTEGER,
|
||||
linkSinkType CTPType,
|
||||
linkSrcType CTPType,
|
||||
linkCTPSink INTEGER,
|
||||
linkCTPSource INTEGER,
|
||||
linkName DisplayString,
|
||||
linkGroupId INTEGER,
|
||||
linkDirection LinkDirection,
|
||||
linkProtectionType ProtectionType,
|
||||
linkProtectionStatus ProtectionStatus,
|
||||
linkTrafficStatus TrafficStatus,
|
||||
linkImplementation SagemBoolean
|
||||
}
|
||||
|
||||
linkIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"linkIndex = number of the CTP Output
|
||||
= sncIndex "
|
||||
::= { linkEntry 1 }
|
||||
|
||||
linkSinkType OBJECT-TYPE
|
||||
SYNTAX CTPType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Kind of CTP table from which the connection is issued"
|
||||
::= { linkEntry 2 }
|
||||
|
||||
linkSrcType OBJECT-TYPE
|
||||
SYNTAX CTPType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Kind of CTP table from which the connection is issued"
|
||||
::= { linkEntry 3 }
|
||||
|
||||
linkCTPSink OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The value of this field indicates the Ouput
|
||||
Connection Point which composes the unidirectionnal
|
||||
link.It's an index in considerated TTP table
|
||||
linkCTPSink = linkIndex"
|
||||
::= { linkEntry 4 }
|
||||
|
||||
linkCTPSource OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The value of this field indicates the Input
|
||||
Connection Point which composes the unidirectionnal
|
||||
link. It's an index in considerated TTP table "
|
||||
::= { linkEntry 5 }
|
||||
|
||||
linkName OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A text string which identifies the name of this link.
|
||||
Links names of a bidirectionnal link must have different name.
|
||||
Same direction SNC protected links have an identical name.
|
||||
M1400 UIT-T specifies the field's format "
|
||||
::= { linkEntry 6 }
|
||||
|
||||
linkGroupId OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A group identifier is used to group links by community."
|
||||
::= { linkEntry 7 }
|
||||
|
||||
linkDirection OBJECT-TYPE
|
||||
SYNTAX LinkDirection
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unidirectional or Bidirectionnal connections."
|
||||
::= { linkEntry 8 }
|
||||
|
||||
linkProtectionType OBJECT-TYPE
|
||||
SYNTAX ProtectionType
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The value of this field indicates the kind of wanted link protection.
|
||||
The default value is NONE.
|
||||
if value is changed in Snc(1)then an entry is created in Snc table with the same index. But this table
|
||||
has to be completed (by setting the PIC,...) to obtain a configured protection.
|
||||
if value is changed in None(0)then the associated entry in Snc table is deleted.
|
||||
When the value is set to Snc for a particular entry of LinkTable, other links which are in relation (of
|
||||
direction or protection) with this main link remain setting to None for this field. But all links are set to the USED(1) value
|
||||
in the next field (linkProtectionStatus)"
|
||||
::= { linkEntry 9 }
|
||||
|
||||
linkProtectionStatus OBJECT-TYPE
|
||||
SYNTAX ProtectionStatus
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The value of this field indicates if the link is used directly or not in a Snc protection.
|
||||
For a non-protected link, this field is mandatory set to None.
|
||||
The field value particulary allow to know the hability of link deletion."
|
||||
::= { linkEntry 10 }
|
||||
|
||||
linkTrafficStatus OBJECT-TYPE
|
||||
SYNTAX TrafficStatus
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The value of this field indicates where is the traffic.
|
||||
For a non-protected link, this field is mandatory set to working"
|
||||
::= { linkEntry 11 }
|
||||
|
||||
linkImplementation OBJECT-TYPE
|
||||
SYNTAX SagemBoolean
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Actually, this variable is not implemented (always set to TRUE).
|
||||
But it could be used to allow to reserve a connection without physical implementation"
|
||||
::= { linkEntry 12 }
|
||||
|
||||
|
||||
|
||||
|
||||
--*******************************************************************
|
||||
-- xcon : creation/deletion of Xconnection
|
||||
-- This vector has been created to allow to:
|
||||
-- * create or delete Xconnection in an atomic way (no need to use Set All command)
|
||||
-- * keep critical variable of linkTable (such as linkIndex) in a Read-Only Access
|
||||
-- * get back a special message in case of trouble.
|
||||
--*******************************************************************
|
||||
XconDir ::= INTEGER
|
||||
{
|
||||
unknown(0), -- Future case of a non-implemented link
|
||||
unidirectional(1),
|
||||
bidirectional(2)
|
||||
}
|
||||
|
||||
ActionType ::= INTEGER
|
||||
{
|
||||
unknown(0),
|
||||
creation(1),
|
||||
deletion(2)
|
||||
}
|
||||
|
||||
|
||||
xconNumber OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Number of connection to process."
|
||||
::= { xcon 1 }
|
||||
|
||||
xconSinkType OBJECT-TYPE
|
||||
SYNTAX CTPType
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Type of CTP"
|
||||
::= { xcon 2 }
|
||||
|
||||
xconSinkIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Output CTP"
|
||||
::= { xcon 3 }
|
||||
|
||||
xconSrcType OBJECT-TYPE
|
||||
SYNTAX CTPType
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Type of CTP"
|
||||
::= { xcon 4 }
|
||||
|
||||
xconSrcIndex OBJECT-TYPE
|
||||
SYNTAX INTEGER(0..2147483647)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Input CTP"
|
||||
::= { xcon 5 }
|
||||
|
||||
xconDirection OBJECT-TYPE
|
||||
SYNTAX XconDir
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Bidirectionnal connections are composed of two unidirectional xcon
|
||||
and therefore 2 link entries."
|
||||
::= { xcon 6 }
|
||||
|
||||
xconName OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A text string which identifies the name of this cross-connection.
|
||||
M1400 UIT-T specifies the field's format like this:
|
||||
NameTownA/NameSuffixA-NameTownB/NameSuffixB NameFunctionSNameSerial
|
||||
* NameTownX field accepts alpha-numeric and space characters.
|
||||
NameTownB is preceded by a '-' character.
|
||||
Maximum length is 12 charracters.
|
||||
Not mandatory fields.
|
||||
* NameSuffixX field accepts alpha-numeric characters.
|
||||
It's preceded by a '/' character.
|
||||
Maximum length is 3 characters.
|
||||
Not mandatory fields.
|
||||
* NameFunction field accepts alpha-numeric characters.
|
||||
It's followed by a 'S' character.
|
||||
Maximum length is 3 characters.
|
||||
Mandatory field.
|
||||
It represents the function code.
|
||||
* NameSerial field accepts 4-figure number.
|
||||
Not mandatory field.
|
||||
It represents the serial number and will be incremented
|
||||
automatically from the base serial number provided.
|
||||
For ADR2500 equipments:
|
||||
Links names of a bidirectionnal link must have different name.
|
||||
Same direction SNC protected links have an identical name."
|
||||
::= { xcon 7 }
|
||||
|
||||
|
||||
xconAction OBJECT-TYPE
|
||||
SYNTAX ActionType
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Type of action: Unknown(0) or Creation(1) or deletion(2)"
|
||||
::= { xcon 8 }
|
||||
|
||||
xconProceed OBJECT-TYPE
|
||||
SYNTAX SagemBoolean
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"
|
||||
This entry is use to create (set to `true').
|
||||
The value of the field remains to `true' until creation is
|
||||
completed or has been aborted.
|
||||
"
|
||||
::= { xcon 20 }
|
||||
|
||||
xconDiagnostic OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A string used to help in case of trouble."
|
||||
::= { xcon 21 }
|
||||
|
||||
END
|