Initial commit
This commit is contained in:
582
MIBS/siae/SIAE-MAB-MIB
Normal file
582
MIBS/siae/SIAE-MAB-MIB
Normal file
@ -0,0 +1,582 @@
|
||||
-- ----------------------------------------------------------------------------
|
||||
--
|
||||
-- SIAE MICROELETTRONICA s.p.a.
|
||||
--
|
||||
-- Via Michelangelo Buonarroti, 21
|
||||
-- 20093 - Cologno Monzese
|
||||
-- Milano
|
||||
-- ITALY
|
||||
--
|
||||
-- ----------------------------------------------------------------------------
|
||||
-- ----------------------------------------------------------------------------
|
||||
|
||||
SIAE-MAB-MIB
|
||||
DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, OBJECT-TYPE,
|
||||
Integer32
|
||||
FROM SNMPv2-SMI
|
||||
RowStatus, MacAddress,
|
||||
TEXTUAL-CONVENTION
|
||||
FROM SNMPv2-TC
|
||||
InterfaceIndex
|
||||
FROM IF-MIB
|
||||
siaeMib
|
||||
FROM SIAE-TREE-MIB;
|
||||
|
||||
mabMib MODULE-IDENTITY
|
||||
LAST-UPDATED "201502170000Z"
|
||||
ORGANIZATION "SIAE MICROELETTRONICA spa"
|
||||
CONTACT-INFO
|
||||
"SIAE MICROELETTONICA s.p.a.
|
||||
Via Michelangelo Buonarroti, 21
|
||||
20093 - Cologno Monzese
|
||||
Milano - ITALY
|
||||
Phone : +39-02-27325-1
|
||||
E-mail: help@siaemic.com
|
||||
"
|
||||
DESCRIPTION
|
||||
"Microwave Adaptive Bandwidth (MAB)
|
||||
|
||||
This management information module supports the configuration of
|
||||
the MW Capacity Management (MCM) feature developed by
|
||||
SIAE MICROELETTRONICA and Cisco that offers reliable QoS and
|
||||
optimized performances even under worst radio propagation
|
||||
conditions.
|
||||
|
||||
The extension to the original functionality, consisting of the
|
||||
Link ID TLV, is considered by this MIB.
|
||||
"
|
||||
REVISION "201502170000Z"
|
||||
DESCRIPTION
|
||||
"Initial version 01.00.00.
|
||||
"
|
||||
::= { siaeMib 93 }
|
||||
|
||||
----------------------------------------------------------------------------------
|
||||
-- Textual Conventions
|
||||
----------------------------------------------------------------------------------
|
||||
|
||||
|
||||
MabBwCalculationMethod ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This Textual Convention describes the method of calculation of the
|
||||
radio bandwitdh (or the throughput of an interface):
|
||||
- average: Average Tx BW value across the observation interval
|
||||
- min: Minimum Tx BW value across the observation interval
|
||||
- max: Maximum Tx BW value across the observation interval
|
||||
"
|
||||
SYNTAX INTEGER {
|
||||
average (1),
|
||||
min (2),
|
||||
max (3)
|
||||
}
|
||||
|
||||
MabPduCompliance ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This Textual Convention describes the compliance of the MAB PDU
|
||||
sent by a MAB PDU sender:
|
||||
- stdMcmCompliant: PDU format is compliant with [1]
|
||||
- extMcmCompliant: PDU format is compliant with [2]
|
||||
- ituG8013Compliant: PDU format is compliant with [4]
|
||||
|
||||
Since [3] and [4] are a draft edition at the time when this MIB
|
||||
is being written, the value ituG8013Compliant(3) is defined for
|
||||
future use.
|
||||
"
|
||||
REFERENCE
|
||||
"[1] - MW CAPACITY MANAGEMENT (MCM) - FUNCTIONAL DESCRIPTION
|
||||
This document provides a description of the MW Capacity
|
||||
Management (MCM) feature developed by SIAE MICROELETTRONICA
|
||||
and Cisco.
|
||||
[2] - E-OAM Extensions for Microwave Adaptive Modulation
|
||||
Cisco Document Number EDCS-997459
|
||||
[3] - Draft revised Recommendation ITU-T G.8021/Y.1341
|
||||
(for Consent, 5 December 2014)
|
||||
[4] - Draft Amendment 1 to Recommendation ITU-T G.8013/Y.1731(2013)
|
||||
(for Consent, 5 December 2014)
|
||||
"
|
||||
SYNTAX INTEGER {
|
||||
stdMcmCompliant (1),
|
||||
extMcmCompliant (2),
|
||||
ituG8013Compliant (3)
|
||||
}
|
||||
|
||||
MabSenderOption ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This Textual Convention describes the supported option of a
|
||||
MAB PDU sender:
|
||||
- enableAlways: Enable periodic PDU sending even if the
|
||||
current bandwidth is equal to the nominal
|
||||
bandwidth.
|
||||
- enableSignalFail: PDU are transmitted periodically when the
|
||||
link fails in the tranmit direction. If the
|
||||
NE usually sends PDUs also when the radio
|
||||
bandwitdh (or the throughput of an interface)
|
||||
is null, this option has no effect.
|
||||
"
|
||||
REFERENCE
|
||||
"[3] - Draft revised Recommendation ITU-T G.8021/Y.1341
|
||||
(for Consent, 5 December 2014)
|
||||
"
|
||||
SYNTAX BITS {
|
||||
enableAlways (0),
|
||||
enableSignalFail (1)
|
||||
}
|
||||
|
||||
----------------------------------------------------------------------------------
|
||||
-- MSP GROUP
|
||||
----------------------------------------------------------------------------------
|
||||
|
||||
------ Beginning --------------------------------------------------------------
|
||||
|
||||
mabMibVersion OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Numerical version of this module.
|
||||
The string version of this MIB have the following format:
|
||||
XX.YY.ZZ
|
||||
so, for example, the value 1 should be interpreted as 00.00.01
|
||||
and the value 10001 should be interpreted as 01.00.01.
|
||||
"
|
||||
::= { mabMib 1}
|
||||
|
||||
------- Begin of mabSensorTable
|
||||
--
|
||||
mabSensorTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF MabSensorEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Table with MAB sensors entries. Each sensor is associated to a
|
||||
interface, usually an interface with the physical layer
|
||||
consisting of a radio link, and comapares the current bandwidth
|
||||
(throughput) with the nominal one. When nominal and current
|
||||
bandwidth doesn't match to PDU senders associated with a sensor
|
||||
is required to send a MAB PDU every observation time.
|
||||
"
|
||||
::= { mabMib 2 }
|
||||
|
||||
mabSensorEntry OBJECT-TYPE
|
||||
SYNTAX MabSensorEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A row in the mabSensorTable.
|
||||
"
|
||||
INDEX { mabSensorIndex }
|
||||
::= { mabSensorTable 1 }
|
||||
|
||||
MabSensorEntry ::=
|
||||
SEQUENCE
|
||||
{
|
||||
mabSensorIndex Integer32,
|
||||
mabSensorRowStatus RowStatus,
|
||||
mabSensorAdminStatus INTEGER,
|
||||
mabSensorIfIndex InterfaceIndex,
|
||||
mabSensorLinkId Integer32,
|
||||
mabSensorBwMode MabBwCalculationMethod,
|
||||
mabSensorHoldoffTime Integer32,
|
||||
mabSensorObservationTime Integer32,
|
||||
mabSensorFastTime Integer32,
|
||||
mabSensorFastCount Integer32
|
||||
}
|
||||
|
||||
mabSensorIndex OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object identifies the MAB sensor inside the Network Element.
|
||||
"
|
||||
::= { mabSensorEntry 1 }
|
||||
|
||||
mabSensorRowStatus OBJECT-TYPE
|
||||
SYNTAX RowStatus
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The status of this MAB sensor entry.
|
||||
|
||||
An entry may not exist in the active state unless all
|
||||
objects in the entry have an appropriate value: mabSensorIfIndex
|
||||
must be set to a valid ifIndex number. Otherwise, the error
|
||||
inconsistentValue is returned on the attempt to set active this
|
||||
row.
|
||||
|
||||
When set to notInService changes may be made to mabSensorIfIndex.
|
||||
Other objects can be changed when mabSensorRowStatus is set to
|
||||
active.
|
||||
|
||||
A sensor can not be deleted if there is any MAB PDU sender
|
||||
associated with it.
|
||||
"
|
||||
::= { mabSensorEntry 2 }
|
||||
|
||||
mabSensorAdminStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
down (1),
|
||||
up (2)
|
||||
}
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Administative status of the MAB sensor.
|
||||
The value down(1) turn off all MAB advisers associated with
|
||||
this sensor.
|
||||
"
|
||||
DEFVAL { down }
|
||||
::= { mabSensorEntry 3 }
|
||||
|
||||
mabSensorIfIndex OBJECT-TYPE
|
||||
SYNTAX InterfaceIndex
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object accepts a greater than zero value to identify an
|
||||
interface in ifTable. The throughput of the selected interface
|
||||
is monitored and notified to all MAB PDU sender associated with
|
||||
this sensor.
|
||||
"
|
||||
::= { mabSensorEntry 4 }
|
||||
|
||||
mabSensorLinkId OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object set the (radio) link identifier that will be inserted
|
||||
in the Link ID TLV of the MAB PDU.
|
||||
"
|
||||
::= { mabSensorEntry 5 }
|
||||
|
||||
mabSensorBwMode OBJECT-TYPE
|
||||
SYNTAX MabBwCalculationMethod
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object defines the method of calculation of the current
|
||||
bandwidth. The value of this parameter is sent inside MAB PDUs.
|
||||
"
|
||||
DEFVAL { average }
|
||||
::= { mabSensorEntry 6 }
|
||||
|
||||
mabSensorHoldoffTime OBJECT-TYPE
|
||||
SYNTAX Integer32(10..60)
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object defines the wait time (in seconds) for MAB protocol
|
||||
before sending packets if the current bandwidth (throughput)
|
||||
is lower than the nominal.
|
||||
"
|
||||
DEFVAL { 10 }
|
||||
::= { mabSensorEntry 7 }
|
||||
|
||||
mabSensorObservationTime OBJECT-TYPE
|
||||
SYNTAX Integer32(1|10|60)
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object defines the observation time (in seconds) for MAB
|
||||
protocol during which calculate the minimum, maximum and average
|
||||
value of the current bandwidth (throughput). At the end of each
|
||||
period, a MAB PDU is sent by every MAB PDU sender associated with
|
||||
this sensor.
|
||||
"
|
||||
DEFVAL { 10 }
|
||||
::= { mabSensorEntry 8 }
|
||||
|
||||
mabSensorFastTime OBJECT-TYPE
|
||||
SYNTAX Integer32(1..59)
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This value is used in place of mabSensorObservationTime for the
|
||||
first mabSensorFastCount PDU packets sent by a MAB PDU sender.
|
||||
The value of mabSensorFastTime must be less than or equal to
|
||||
mabSensorObservationTime.
|
||||
"
|
||||
REFERENCE
|
||||
"Draft revised Recommendation ITU-T G.8021/Y.1341 (for Consent,
|
||||
5 December 2014) - 8.1.18 BNM insert process
|
||||
"
|
||||
DEFVAL { 10 }
|
||||
::= { mabSensorEntry 9 }
|
||||
|
||||
mabSensorFastCount OBJECT-TYPE
|
||||
SYNTAX Integer32(0..60)
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This value specifies how many MAB PDU packets are sent every
|
||||
mabSensorFastTime before to use the standard observation time
|
||||
(mabSensorObservationTime).
|
||||
Zero means which quick sending of packets is disabled.
|
||||
"
|
||||
REFERENCE
|
||||
"Draft revised Recommendation ITU-T G.8021/Y.1341 (for Consent,
|
||||
5 December 2014) - 8.1.18 BNM insert process
|
||||
"
|
||||
DEFVAL { 0 }
|
||||
::= { mabSensorEntry 10 }
|
||||
|
||||
--
|
||||
------- End of mabSensorTable
|
||||
|
||||
------- Begin of mabSensorStatusTable
|
||||
--
|
||||
mabSensorStatusTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF MabSensorStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Table with the status of MAB sensor entries. For each row in
|
||||
mabSensorTable a row is created in this table.
|
||||
"
|
||||
::= { mabMib 3 }
|
||||
|
||||
mabSensorStatusEntry OBJECT-TYPE
|
||||
SYNTAX MabSensorStatusEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A row in the mabSensorTable.
|
||||
"
|
||||
INDEX { mabSensorIndex }
|
||||
::= { mabSensorStatusTable 1 }
|
||||
|
||||
MabSensorStatusEntry ::=
|
||||
SEQUENCE
|
||||
{
|
||||
mabSensorNominalBw Integer32,
|
||||
mabSensorCurrentBw Integer32
|
||||
}
|
||||
|
||||
mabSensorNominalBw OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object reports the nominal bandwidth (throughput) of the
|
||||
interface selected by mabSensorIfIndex.
|
||||
"
|
||||
::= { mabSensorStatusEntry 1 }
|
||||
|
||||
mabSensorCurrentBw OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object reports the current bandwidth (throughput) of the
|
||||
interface selected by mabSensorIfIndex and calculated according
|
||||
to the method set in mabSensorBwMode.
|
||||
"
|
||||
::= { mabSensorStatusEntry 2 }
|
||||
--
|
||||
------- End of mabSensorStatusTable
|
||||
|
||||
------- Begin of mabPduSenderTable
|
||||
--
|
||||
mabPduSenderTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF MabPduSenderEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Table with MAB PDU sender entries. Each PDU sender refers to an
|
||||
ifIndex in ifTable on which to send a PDU MAB and a sensor that
|
||||
triggers the sending.
|
||||
"
|
||||
::= { mabMib 4 }
|
||||
|
||||
mabPduSenderEntry OBJECT-TYPE
|
||||
SYNTAX MabPduSenderEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A row in the mabPduSenderTable.
|
||||
"
|
||||
INDEX { mabPduSenderIndex }
|
||||
::= { mabPduSenderTable 1 }
|
||||
|
||||
MabPduSenderEntry ::=
|
||||
SEQUENCE
|
||||
{
|
||||
mabPduSenderIndex Integer32,
|
||||
mabPduSenderRowStatus RowStatus,
|
||||
mabPduSenderAdminStatus INTEGER,
|
||||
mabPduSenderIfIndex InterfaceIndex,
|
||||
mabPduSenderSensorIndex Integer32,
|
||||
mabPduSenderVlanId Integer32,
|
||||
mabPduSenderPcp Integer32,
|
||||
mabPduSenderOamMaintLevel Integer32,
|
||||
mabPduSenderDAType INTEGER,
|
||||
mabPduSenderUnicastDA MacAddress,
|
||||
mabPduSenderOption MabSenderOption,
|
||||
mabPduSenderPduCompliance MabPduCompliance
|
||||
}
|
||||
|
||||
mabPduSenderIndex OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object identifies the MAB PDU sender inside the Network
|
||||
Element.
|
||||
"
|
||||
::= { mabPduSenderEntry 1 }
|
||||
|
||||
mabPduSenderRowStatus OBJECT-TYPE
|
||||
SYNTAX RowStatus
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The status of this mabPduSender entry.
|
||||
|
||||
An entry may not exist in the active state unless all objects in
|
||||
the entry have an appropriate value: mabPduSenderIfIndex must be
|
||||
set to a valid ifIndex number and mabPduSenderSensorIndex must be
|
||||
set to a valid MAB sensor, Otherwise, the error inconsistentValue
|
||||
is returned on the attempt to set active this row.
|
||||
|
||||
When set to notInService changes may be made to mabPduSenderIfIndex,
|
||||
mabPduSenderSensorIndex. Other objects can be changed when
|
||||
mabPduSenderRowStatus is set to active.
|
||||
"
|
||||
::= { mabPduSenderEntry 2 }
|
||||
|
||||
mabPduSenderAdminStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
down (1),
|
||||
up (2)
|
||||
}
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Administative status of the MAB PDU sender.
|
||||
"
|
||||
DEFVAL { down }
|
||||
::= { mabPduSenderEntry 3 }
|
||||
|
||||
mabPduSenderIfIndex OBJECT-TYPE
|
||||
SYNTAX InterfaceIndex
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object accepts a greater than zero value to identify an
|
||||
interface in ifTable. MAB PDU is sent over this interface.
|
||||
"
|
||||
::= { mabPduSenderEntry 4 }
|
||||
|
||||
mabPduSenderSensorIndex OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object associates a MAB sensor to this PDU sender.
|
||||
"
|
||||
::= { mabPduSenderEntry 5 }
|
||||
|
||||
mabPduSenderVlanId OBJECT-TYPE
|
||||
SYNTAX Integer32(0|1..4094)
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object defines the VLAN identifier used to tag the MAB PDU.
|
||||
Zero means the PDU is not tagged.
|
||||
"
|
||||
DEFVAL { 0 }
|
||||
::= { mabPduSenderEntry 6 }
|
||||
|
||||
mabPduSenderPcp OBJECT-TYPE
|
||||
SYNTAX Integer32(0..7)
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object defines packet priority written into the tag of
|
||||
the MAB PDU.
|
||||
"
|
||||
DEFVAL { 7 }
|
||||
::= { mabPduSenderEntry 7 }
|
||||
|
||||
mabPduSenderOamMaintLevel OBJECT-TYPE
|
||||
SYNTAX Integer32(0..7)
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object defines the OAM maintenance level of the MAB PDU.
|
||||
The multicast destination address of the PDU is according to
|
||||
the selected maintenance level:
|
||||
01-80-C2-00-00-3x
|
||||
where x = Maintenance Level
|
||||
"
|
||||
DEFVAL { 0 }
|
||||
::= { mabPduSenderEntry 8 }
|
||||
|
||||
mabPduSenderDAType OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
multicastDA(1),
|
||||
unicastDA (2)
|
||||
}
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object defines the destination MAC address type of the PDU:
|
||||
- multicastDA(1): Multicast Class 1 Destination Address (DA)
|
||||
- unicastDA(2): Unicast Destination Address (DA)
|
||||
"
|
||||
DEFVAL { multicastDA }
|
||||
::= { mabPduSenderEntry 9 }
|
||||
|
||||
mabPduSenderUnicastDA OBJECT-TYPE
|
||||
SYNTAX MacAddress
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object defines the unuicast destination address of the PDU
|
||||
when mabPduSenderDAType is set to unicastDA(2).
|
||||
"
|
||||
DEFVAL { '000000000000'H }
|
||||
::= { mabPduSenderEntry 10 }
|
||||
|
||||
mabPduSenderOption OBJECT-TYPE
|
||||
SYNTAX MabSenderOption
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object enable the option supported by the MAB PDU sender:
|
||||
- enableAlways: Enable periodic PDU sending even if the
|
||||
current bandwidth is equal to the nominal
|
||||
bandwidth.
|
||||
- enableSignalFail: PDU are transmitted periodically when the
|
||||
link fails in the tranmit direction. If the
|
||||
NE usually sends PDUs also when the radio
|
||||
bandwitdh (or the throughput of an interface)
|
||||
is null, this option has no effect.
|
||||
"
|
||||
-- DEFVAL { { } }
|
||||
::= { mabPduSenderEntry 11 }
|
||||
|
||||
mabPduSenderPduCompliance OBJECT-TYPE
|
||||
SYNTAX MabPduCompliance
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object defines the compliance of the MAB PDU format.
|
||||
"
|
||||
DEFVAL { stdMcmCompliant }
|
||||
::= { mabPduSenderEntry 12 }
|
||||
|
||||
--
|
||||
------- End of mabPduSenderTable
|
||||
|
||||
|
||||
------ End group -------------------------------------------------------------
|
||||
|
||||
END
|
Reference in New Issue