Initial commit
This commit is contained in:
210
MIBS/telco-systems/binos/PRVT-NETWORK-LOOPBACK-TEST-MIB
Normal file
210
MIBS/telco-systems/binos/PRVT-NETWORK-LOOPBACK-TEST-MIB
Normal file
@ -0,0 +1,210 @@
|
||||
-- *********************************************************************
|
||||
-- *********************************************************************
|
||||
-- ** Filename: PRVT-NETWORK-LOOPBACK-TEST-MIB
|
||||
-- ** Project: Network Loopback Tester
|
||||
-- ** Purpose: Private MIB
|
||||
-- *********************************************************************
|
||||
-- (c) Copyright, 2001, BATM Advanced Communications. All rights reserved.
|
||||
-- WARNING:
|
||||
--
|
||||
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
|
||||
--
|
||||
-- This file is the property of BATM Advanced Communications.
|
||||
-- BATM Advanced Communications retains all title and
|
||||
-- ownership in the Specification, including any revisions.
|
||||
|
||||
-- BATM Advanced Communications grants all interested parties a non-exclusive
|
||||
-- license to use and distribute an unmodified copy of this
|
||||
-- Specification in connection with management of BATM Advanced Communications
|
||||
-- and Telco Systems<6D>products, and without fee, provided that the following
|
||||
-- conditions are met:
|
||||
-- 1. Redistributions of this specification must retain the above copyright
|
||||
-- notice, this list of conditions and the following disclaimer.
|
||||
-- 2. Redistributions in binary form must reproduce the above copyright
|
||||
-- notice, this list of conditions and the following disclaimer in the
|
||||
-- documentation and/or other materials provided with the distribution.
|
||||
-- 3. The name of the BATM Advanced Communications MAY NOT be used to endorse
|
||||
-- or promote products derived from this specification without specific prior written
|
||||
-- permission.
|
||||
--
|
||||
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
|
||||
-- WARRANTY, THE SPECIFICATIONS CONTAINED IN THIS FILE ARE
|
||||
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
|
||||
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
|
||||
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
|
||||
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
|
||||
-- INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
|
||||
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
|
||||
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
|
||||
-- TO USE, THE SPECIFICATION CONTAINED IN THIS FILE.
|
||||
PRVT-NETWORK-LOOPBACK-TEST-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY,
|
||||
OBJECT-TYPE
|
||||
FROM SNMPv2-SMI
|
||||
|
||||
ifIndex
|
||||
FROM IF-MIB
|
||||
|
||||
MODULE-COMPLIANCE,
|
||||
OBJECT-GROUP,
|
||||
NOTIFICATION-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
|
||||
TimeStamp,
|
||||
RowStatus
|
||||
FROM SNMPv2-TC
|
||||
|
||||
NOTIFICATION-TYPE
|
||||
FROM SNMPv2-SMI -- [RFC2578]
|
||||
|
||||
|
||||
accessListControlListGroup
|
||||
FROM PRVT-SWITCH-ACCESS-LIST-MIB
|
||||
|
||||
ipSwitch FROM PRVT-SWITCH-MIB;
|
||||
|
||||
-- The NETWORK LOOPBACK TEST MIB
|
||||
prvtNetworkLoopbackTestMib MODULE-IDENTITY
|
||||
|
||||
LAST-UPDATED "201008310000Z"
|
||||
ORGANIZATION "BATM Advanced Communication"
|
||||
CONTACT-INFO
|
||||
"BATM/Telco Systems Support team
|
||||
Email:
|
||||
For North America: techsupport@telco.com
|
||||
For North Europe: support@batm.de, info@batm.de
|
||||
For the rest of the world: techsupport@telco.com"
|
||||
|
||||
DESCRIPTION
|
||||
"This MIB contains managed objects definitions for
|
||||
encapsulating Loopback Tester feature that enables or disables
|
||||
embedded mechanisms for network troubleshooting, diagnostics and measurement."
|
||||
|
||||
REVISION "201008310000Z"
|
||||
DESCRIPTION
|
||||
"Initial version."
|
||||
|
||||
::= { ipSwitch 7 }
|
||||
|
||||
prvtNetworkLoopbackTestNotifications OBJECT IDENTIFIER ::= { prvtNetworkLoopbackTestMib 0 }
|
||||
prvtNetworkLoopbackTestObjects OBJECT IDENTIFIER ::= { prvtNetworkLoopbackTestMib 1 }
|
||||
prvtNetworkLoopbackTestConformance OBJECT IDENTIFIER ::= { prvtNetworkLoopbackTestMib 2 }
|
||||
|
||||
prvtNetworkLoopbackTestTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF PrvtNetworkLoopbackTestEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains object for configuring and display information about Network Loopback Tester."
|
||||
::= { prvtNetworkLoopbackTestObjects 1 }
|
||||
|
||||
prvtNetworkLoopbackTestEntry OBJECT-TYPE
|
||||
SYNTAX PrvtNetworkLoopbackTestEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry in the prvtNetworkLoopbackTestTable table"
|
||||
INDEX { ifIndex, accessListControlListGroup }
|
||||
::= { prvtNetworkLoopbackTestTable 1 }
|
||||
|
||||
PrvtNetworkLoopbackTestEntry ::= SEQUENCE {
|
||||
prvtNetworkLoopTestDuration INTEGER,
|
||||
prvtNetworkLoopStartDuration TimeStamp,
|
||||
prvtNetworkLoopEndDuration TimeStamp,
|
||||
prvtNetworkLoopRowStatus RowStatus
|
||||
}
|
||||
|
||||
prvtNetworkLoopTestDuration OBJECT-TYPE
|
||||
SYNTAX INTEGER (0..100000)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An integer that identifies the duration in seconds of Loopback test.
|
||||
For infinite Loopback tests object will have the value 0."
|
||||
::= {prvtNetworkLoopbackTestEntry 1}
|
||||
|
||||
prvtNetworkLoopStartDuration OBJECT-TYPE
|
||||
SYNTAX TimeStamp
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Star time of Loopback test.
|
||||
For infinite Loopback tests object will have the value 0."
|
||||
::= {prvtNetworkLoopbackTestEntry 2}
|
||||
|
||||
prvtNetworkLoopEndDuration OBJECT-TYPE
|
||||
SYNTAX TimeStamp
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"End time of Loopback test.
|
||||
For infinite Loopback tests object will have the value 0."
|
||||
::= {prvtNetworkLoopbackTestEntry 3}
|
||||
|
||||
prvtNetworkLoopRowStatus OBJECT-TYPE
|
||||
SYNTAX RowStatus
|
||||
MAX-ACCESS read-create
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Network Loopback Test RowStatus.
|
||||
Both createAndGo(4) and createAndWait(5) are available.
|
||||
CreateAndGo(4) is used for enable a Loopback test unlimited in time and CreateAndWait(4)
|
||||
for enable a Loopback Test on a period specified by prvtNetworkLoopTestDuration."
|
||||
::= {prvtNetworkLoopbackTestEntry 4}
|
||||
|
||||
-- ----------------------------------------------------------------------------
|
||||
-- Notifications
|
||||
-- ----------------------------------------------------------------------------
|
||||
|
||||
prvtNetworkLoopbackTestFinish NOTIFICATION-TYPE
|
||||
OBJECTS { ifIndex, accessListControlListGroup }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This notification is sent when a Network Loopback Test is complete."
|
||||
::= {prvtNetworkLoopbackTestNotifications 1}
|
||||
|
||||
-- ----------------------------------------------------------------------------
|
||||
-- Conformance Information
|
||||
-- ----------------------------------------------------------------------------
|
||||
prvtNetworkLoopTestCompliances OBJECT IDENTIFIER ::= {prvtNetworkLoopbackTestConformance 1}
|
||||
prvtNetworkLoopTestGroups OBJECT IDENTIFIER ::= {prvtNetworkLoopbackTestConformance 2}
|
||||
|
||||
-- compliance statements
|
||||
prvtNetworkLoopTestCompliance MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The compliance statement for Network Loopback Tester."
|
||||
MODULE -- this module
|
||||
MANDATORY-GROUPS {
|
||||
prvtNetworkLoopTestGroup,
|
||||
prvtNetworkLoopTestNotificationsGroup
|
||||
}
|
||||
::= {prvtNetworkLoopTestCompliances 1}
|
||||
|
||||
prvtNetworkLoopTestGroup OBJECT-GROUP
|
||||
OBJECTS {prvtNetworkLoopTestDuration,
|
||||
prvtNetworkLoopStartDuration,
|
||||
prvtNetworkLoopEndDuration,
|
||||
prvtNetworkLoopRowStatus
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The group of objects regarding Network Looback Tester feature."
|
||||
::= {prvtNetworkLoopTestGroups 1}
|
||||
|
||||
prvtNetworkLoopTestNotificationsGroup NOTIFICATION-GROUP
|
||||
NOTIFICATIONS{
|
||||
prvtNetworkLoopbackTestFinish
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The collection of Notifications used to indicate general status information
|
||||
of Network Looback Tester feature."
|
||||
::= {prvtNetworkLoopTestGroups 2}
|
||||
|
||||
END
|
||||
|
||||
|
||||
|
Reference in New Issue