-- ** Filename: PRVT-SYS-MON-MIB
|
||||
-- ** Project: T - Ethernet and Fast Ethernet IP Switches.
|
||||
-- ** Purpose: Private MIB
|
||||
-- *********************************************************************
|
||||
-- (c) Copyright, 2001, BATM Advanced Communications. All rights reserved.
|
||||
-- WARNING:
|
||||
--
|
||||
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
|
||||
--
|
||||
-- This file is the property of BATM Advanced Communications.
|
||||
-- BATM Advanced Communications retains all title and
|
||||
-- ownership in the Specification, including any revisions.
|
||||
|
||||
-- BATM Advanced Communications grants all interested parties a non-exclusive
|
||||
-- license to use and distribute an unmodified copy of this
|
||||
-- Specification in connection with management of BATM Advanced Communications
|
||||
-- and Telco Systems<6D>products, and without fee, provided that the following
|
||||
-- conditions are met:
|
||||
-- 1. Redistributions of this specification must retain the above copyright
|
||||
-- notice, this list of conditions and the following disclaimer.
|
||||
-- 2. Redistributions in binary form must reproduce the above copyright
|
||||
-- notice, this list of conditions and the following disclaimer in the
|
||||
-- documentation and/or other materials provided with the distribution.
|
||||
-- 3. The name of the BATM Advanced Communications MAY NOT be used to endorse
|
||||
-- or promote products derived from this specification without specific prior written
|
||||
-- permission.
|
||||
--
|
||||
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
|
||||
-- WARRANTY, THE SPECIFICATIONS CONTAINED IN THIS FILE ARE
|
||||
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
|
||||
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
|
||||
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
|
||||
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
|
||||
-- INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
|
||||
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
|
||||
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
|
||||
-- TO USE, THE SPECIFICATION CONTAINED IN THIS FILE.
|
||||
|
||||
PRVT-SYS-MON-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, OBJECT-TYPE,
|
||||
Integer32 ,NOTIFICATION-TYPE
|
||||
FROM SNMPv2-SMI
|
||||
|
||||
NOTIFICATION-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
TEXTUAL-CONVENTION
|
||||
FROM SNMPv2-TC
|
||||
DisplayString
|
||||
FROM SNMPv2-TC
|
||||
reportsL2IfaceUnit, reportsL2IfaceSlot,
|
||||
reportsL2IfacePort, reportsIfJackIndex,
|
||||
prvt-products
|
||||
FROM PRVT-SWITCH-MIB;
|
||||
|
||||
|
||||
prvtSysMonMib MODULE-IDENTITY
|
||||
LAST-UPDATED "200712270000Z"
|
||||
ORGANIZATION "BATM Advanced Communication"
|
||||
CONTACT-INFO
|
||||
" BATM/Telco Systems Support team
|
||||
Email:
|
||||
For North America: techsupport@telco.com
|
||||
For North Europe: support@batm.de, info@batm.de
|
||||
For the rest of the world: techsupport@telco.com"
|
||||
|
||||
DESCRIPTION
|
||||
"Information for system resources"
|
||||
|
||||
REVISION "200712270000Z"
|
||||
DESCRIPTION
|
||||
"Added laser management"
|
||||
REVISION "200502160000Z"
|
||||
DESCRIPTION
|
||||
"Fixed spelling errors and changed the contact info."
|
||||
|
||||
REVISION "200311180000Z"
|
||||
DESCRIPTION
|
||||
"Add new notifications portsCRCErrExceeded, portsRuntsExceeded,
|
||||
portsOverSizeExceeded and support vars for them.
|
||||
Change the MAX-ACCESS for all
|
||||
sysMonValues to accessible-for-notify"
|
||||
REVISION "200305130000Z"
|
||||
DESCRIPTION
|
||||
"Initial version."
|
||||
::= { software 3 }
|
||||
|
||||
|
||||
|
||||
-------------------------------------------------------------------------------
|
||||
-- PRIVATE BRANCH PRODUCTS
|
||||
-------------------------------------------------------------------------------
|
||||
software OBJECT IDENTIFIER ::= { prvt-products 111 }
|
||||
|
||||
----------------------------------------------------------------------------
|
||||
-- Variable Type definitions
|
||||
----------------------------------------------------------------------------
|
||||
EnableStatus ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"enable(1), disable(2)"
|
||||
SYNTAX INTEGER {
|
||||
enable(1),
|
||||
disable(2)
|
||||
}
|
||||
|
||||
prvtSysMonNotifications OBJECT IDENTIFIER ::= { prvtSysMonMib 0 }
|
||||
prvtSysMonObjects OBJECT IDENTIFIER ::= { prvtSysMonMib 1 }
|
||||
prvtSysMonConformance OBJECT IDENTIFIER ::= { prvtSysMonMib 2 }
|
||||
|
||||
sysMonThreshold OBJECT IDENTIFIER ::= {prvtSysMonObjects 1}
|
||||
sysMonValues OBJECT IDENTIFIER ::= {prvtSysMonObjects 2}
|
||||
sysMonConfig OBJECT IDENTIFIER ::= {prvtSysMonObjects 3}
|
||||
|
||||
cpuUtilizationThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"High limit in percent of normal CPU utilization"
|
||||
::= { sysMonThreshold 1 }
|
||||
|
||||
ramBytesFreeThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Low limit in bytes free in the system memory"
|
||||
::= { sysMonThreshold 2 }
|
||||
|
||||
portErrorsThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"High limit in percent of communication errors on port"
|
||||
::= { sysMonThreshold 3 }
|
||||
|
||||
portsBroadcastThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"High limit in percent of exceeding broadcast-limit on port"
|
||||
::= { sysMonThreshold 4 }
|
||||
|
||||
portsCRCErrThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"High limit in percent of exceeding CRC error on port"
|
||||
::= { sysMonThreshold 5 }
|
||||
|
||||
portsRuntsThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"High limit in percent of exceeding runts on port"
|
||||
::= { sysMonThreshold 6 }
|
||||
|
||||
portsOverSizeThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"High limit in percent of exceeding over-size on port"
|
||||
::= { sysMonThreshold 7 }
|
||||
|
||||
laserPortThresholdTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF LaserPortThresholdEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Defines thresholds for each port in the device"
|
||||
::= { sysMonThreshold 8 }
|
||||
|
||||
laserPortThresholdEntry OBJECT-TYPE
|
||||
SYNTAX LaserPortThresholdEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
INDEX { reportsL2IfaceUnit, reportsL2IfaceSlot, reportsL2IfacePort, reportsIfJackIndex}
|
||||
::= { laserPortThresholdTable 1 }
|
||||
|
||||
LaserPortThresholdEntry ::= SEQUENCE {
|
||||
laserTemperatureHighThreshold Integer32,
|
||||
laserTemperatureLowThreshold Integer32,
|
||||
laserTxPowerHighThreshold Integer32,
|
||||
laserTxPowerLowThreshold Integer32,
|
||||
laserRxPowerHighThreshold Integer32,
|
||||
laserRxPowerLowThreshold Integer32
|
||||
}
|
||||
|
||||
laserTemperatureHighThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Configures high temperature threshold. The range is -128 to 128. The accuracy is 1C."
|
||||
::= { laserPortThresholdEntry 1 }
|
||||
|
||||
laserTemperatureLowThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Configures low temperature threshold. The range is -128 to 128. The accuracy is 1C."
|
||||
::= { laserPortThresholdEntry 2 }
|
||||
|
||||
laserTxPowerHighThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Configures Tx power high threshold. The range is -40 to 8."
|
||||
::= { laserPortThresholdEntry 3 }
|
||||
|
||||
laserTxPowerLowThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Configures Tx power low threshold. The range is -40 to 8."
|
||||
::= { laserPortThresholdEntry 4 }
|
||||
|
||||
laserRxPowerHighThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Configures Rx power high threshold. The range is -40 to 8."
|
||||
::= { laserPortThresholdEntry 5 }
|
||||
|
||||
laserRxPowerLowThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Configures Rx power low threshold. The range is -40 to 8."
|
||||
::= { laserPortThresholdEntry 6 }
|
||||
|
||||
monCpuUtilization OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The current level in percent of CPU utilization"
|
||||
::= { sysMonValues 1 }
|
||||
|
||||
monRamBytesFree OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS accessible-for-notify
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The number of bytes currently free in the system memory"
|
||||
::= { sysMonValues 2 }
|
||||
|
||||
monPortsTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF MonPortsEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Defines the ports monitor Table for providing, via SNMP, the
|
||||
last sampled parameters by the periodic monitor"
|
||||
::= { sysMonValues 3 }
|
||||
|
||||
monPortsEntry OBJECT-TYPE
|
||||
SYNTAX MonPortsEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Defines an entry in the monPortsTable. The entries are indexed by
|
||||
the physical location of the port in the device."
|
||||
INDEX { reportsL2IfaceUnit, reportsL2IfaceSlot, reportsL2IfacePort }
|
||||
::= { monPortsTable 1 }
|
||||
|
||||
MonPortsEntry ::= SEQUENCE {
|
||||
monPortErrors Integer32,
|
||||
monPortBroadcast Integer32,
|
||||
monPortCRCErr Integer32,
|
||||
monPortRunts Integer32,
|
||||
monPortOverSize Integer32
|
||||
}
|
||||
|
||||
monPortErrors OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS accessible-for-notify
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The percentages of errors on the port that generated the notification."
|
||||
::= { monPortsEntry 1 }
|
||||
|
||||
monPortBroadcast OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS accessible-for-notify
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The percentages of packets exceeding broadcast-limit on the port that generated the notification."
|
||||
::= { monPortsEntry 2 }
|
||||
|
||||
monPortCRCErr OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS accessible-for-notify
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The percentage of CRC errors on the port that generated the notification."
|
||||
::= { monPortsEntry 3 }
|
||||
|
||||
monPortRunts OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS accessible-for-notify
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The percentage of runt packets on the port that generated the notification."
|
||||
::= { monPortsEntry 4 }
|
||||
|
||||
monPortOverSize OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS accessible-for-notify
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The percentage of over-size packets on the port that generated the notification."
|
||||
::= { monPortsEntry 5 }
|
||||
|
||||
laserPortValueTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF LaserPortValueEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table displays the current laser-related values for each port in the device."
|
||||
::= { sysMonValues 4 }
|
||||
|
||||
laserPortValueEntry OBJECT-TYPE
|
||||
SYNTAX LaserPortValueEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
INDEX { reportsL2IfaceUnit, reportsL2IfaceSlot, reportsL2IfacePort, reportsIfJackIndex }
|
||||
::= { laserPortValueTable 1 }
|
||||
|
||||
LaserPortValueEntry ::= SEQUENCE {
|
||||
sfpStatus INTEGER,
|
||||
laserTemperature Integer32,
|
||||
laserTxPower Integer32,
|
||||
laserRxPower Integer32
|
||||
}
|
||||
|
||||
sfpStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
lm-supported(1),
|
||||
lm-not-supported(2),
|
||||
extracted(3)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"If value of this field is not supported, then
|
||||
the values of other fields are not relevant.
|
||||
The value is supported only if SFP compliant
|
||||
with SFF-8472 is inserted."
|
||||
::= { laserPortValueEntry 1 }
|
||||
|
||||
laserTemperature OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Represents module temperature.
|
||||
The range is -128 to 128. The accuracy is 1C."
|
||||
::= { laserPortValueEntry 2 }
|
||||
|
||||
laserTxPower OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Represents Tx power. The range is -40 to 8."
|
||||
::= { laserPortValueEntry 3 }
|
||||
|
||||
laserRxPower OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Represents Rx power. The range is -40 to 8."
|
||||
::= { laserPortValueEntry 4 }
|
||||
|
||||
cpuUtilizationExceeded NOTIFICATION-TYPE
|
||||
OBJECTS { monCpuUtilization, cpuUtilizationThreshold}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The cpuUtilizationExceeded notification indicates that the sending
|
||||
agent sense that the CPU utilization has passed the
|
||||
program threshold."
|
||||
::= {prvtSysMonNotifications 1}
|
||||
|
||||
ramFreeSpaceExceeded NOTIFICATION-TYPE
|
||||
OBJECTS { monRamBytesFree, ramBytesFreeThreshold}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The ramFreeSpaceExceeded notification indicates that the sending
|
||||
agent sense that the system memory utilization has passed the
|
||||
program threshold."
|
||||
::= {prvtSysMonNotifications 2}
|
||||
|
||||
portErrorsExceeded NOTIFICATION-TYPE
|
||||
OBJECTS { monPortErrors, portErrorsThreshold}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The portErrorsExceeded notification indicates that the sending
|
||||
agent sense that the level of errors on the port
|
||||
has passed the program threshold."
|
||||
::= {prvtSysMonNotifications 3}
|
||||
|
||||
portsBroadcastExceeded NOTIFICATION-TYPE
|
||||
OBJECTS { monPortBroadcast, portsBroadcastThreshold}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The portsBroadcastExceeded notification indicates that the sending
|
||||
agent sense that the level of broadcast-limit has passed the
|
||||
program threshold."
|
||||
::= {prvtSysMonNotifications 4}
|
||||
|
||||
portsCRCErrExceeded NOTIFICATION-TYPE
|
||||
OBJECTS { monPortCRCErr, portsCRCErrThreshold}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The portsCRCErrExceeded notification indicates that the sending
|
||||
agent sense that the level of CRC error has passed the
|
||||
program threshold."
|
||||
::= {prvtSysMonNotifications 5}
|
||||
|
||||
portsRuntsExceeded NOTIFICATION-TYPE
|
||||
OBJECTS { monPortRunts, portsRuntsThreshold}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The portsRuntsExceeded notification indicates that the sending
|
||||
agent sense that the level of runts has passed the
|
||||
program threshold."
|
||||
::= {prvtSysMonNotifications 6}
|
||||
|
||||
portsOverSizeExceeded NOTIFICATION-TYPE
|
||||
OBJECTS { monPortOverSize, portsOverSizeThreshold}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The portsOverSizeExceeded notification indicates that the sending
|
||||
agent sense that the level of oversize has passed the
|
||||
program threshold."
|
||||
::= {prvtSysMonNotifications 7}
|
||||
|
||||
laserTemperatureThresholdCrossed NOTIFICATION-TYPE
|
||||
OBJECTS { laserTemperature, laserTemperatureHighThreshold, laserTemperatureLowThreshold }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The laserTemperatureThresholdCrossed shall be generated
|
||||
when laserTemperature rises above laserHighTemperatureThreshold
|
||||
or falls below laserTemperatureLowThreshold. Also the
|
||||
notification shall be generated when laserTemperature
|
||||
returns to the normal range between laserHighTemperatureThreshold
|
||||
and laserTemperatureLowThreshold."
|
||||
::= { prvtSysMonNotifications 8 }
|
||||
|
||||
laserTxPowerThresholdCrossed NOTIFICATION-TYPE
|
||||
OBJECTS { laserTxPower, laserTxPowerHighThreshold, laserTxPowerLowThreshold }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The laserTxPowerThresholdCrossed shall be generated
|
||||
when laserTxPower rises above laserHighTxPowerThreshold
|
||||
or falls below laserTxPowerLowThreshold. Also the
|
||||
notification shall be generated when laserTxPower
|
||||
returns to the normal range between
|
||||
laserHighTxPowerThreshold and laserTxPowerLowThreshold."
|
||||
::= { prvtSysMonNotifications 9 }
|
||||
|
||||
laserRxPowerThresholdCrossed NOTIFICATION-TYPE
|
||||
OBJECTS { laserRxPower, laserRxPowerHighThreshold, laserRxPowerLowThreshold }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The laserRxPowerThresholdCrossed shall be generated
|
||||
when laserRxPower rises above laserHighRxPowerThreshold
|
||||
or falls below laserRxPowerLowThreshold. Also the
|
||||
notification shall be generated when laserRxPower
|
||||
returns to the normal range between
|
||||
laserHighRxPowerThreshold and laserRxPowerLowThreshold."
|
||||
::= { prvtSysMonNotifications 10 }
|
||||
sfpMonStatusChanged NOTIFICATION-TYPE
|
||||
OBJECTS { sfpMonStatus }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This trap will be send only if the SFP is inserted or extracted"
|
||||
::= { prvtSysMonNotifications 11 }
|
||||
sfpPortManTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF SfpPortManEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table will be responsible for managing SFPs."
|
||||
::= { sysMonValues 5 }
|
||||
|
||||
sfpPortManEntry OBJECT-TYPE
|
||||
SYNTAX SfpPortManEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
INDEX { reportsL2IfaceUnit, reportsL2IfaceSlot, reportsL2IfacePort, reportsIfJackIndex }
|
||||
::= { sfpPortManTable 1 }
|
||||
|
||||
SfpPortManEntry ::= SEQUENCE {
|
||||
sfpMonStatus INTEGER,
|
||||
sfpVendor DisplayString,
|
||||
sfpPN DisplayString,
|
||||
sfpRevision DisplayString,
|
||||
sfpLenght DisplayString,
|
||||
sfpConnector DisplayString
|
||||
}
|
||||
|
||||
sfpMonStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
sfpInserted (1),
|
||||
sfpExtracted (2),
|
||||
sfpUnknown (3)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object gives information is SFP is inserted or not in the port."
|
||||
::= { sfpPortManEntry 1 }
|
||||
|
||||
sfpVendor OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..9))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "This object gives SFP vendor name."
|
||||
DEFVAL { ''H }
|
||||
::= { sfpPortManEntry 2 }
|
||||
|
||||
sfpPN OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..9))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "This object gives SFP vendor name."
|
||||
DEFVAL { ''H }
|
||||
::= { sfpPortManEntry 3 }
|
||||
|
||||
sfpRevision OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..9))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "This object gives SFP vendor revision."
|
||||
DEFVAL { ''H }
|
||||
::= { sfpPortManEntry 4 }
|
||||
|
||||
sfpLenght OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..9))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "This object gives information regarding link length."
|
||||
DEFVAL { ''H }
|
||||
::= { sfpPortManEntry 5 }
|
||||
|
||||
sfpConnector OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..9))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION "This object gives SFP connector type."
|
||||
DEFVAL { ''H }
|
||||
::= { sfpPortManEntry 6 }
|
||||
|
||||
------------------------------------------------------------------------
|
||||
---------------------------sysMonConfig---------------------------------
|
||||
------------------------------------------------------------------------
|
||||
|
||||
sysMonConfigTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF SysMonConfigEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table configures periodic monitoring parameters."
|
||||
::= { sysMonConfig 1 }
|
||||
|
||||
sysMonConfigEntry OBJECT-TYPE
|
||||
SYNTAX SysMonConfigEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
""
|
||||
INDEX { sysMonIndicator }
|
||||
::= { sysMonConfigTable 1 }
|
||||
|
||||
SysMonConfigEntry ::= SEQUENCE {
|
||||
sysMonIndicator INTEGER,
|
||||
sysMonEnable EnableStatus,
|
||||
sysMonPeriod Integer32,
|
||||
sysMonTrap EnableStatus,
|
||||
sysMonLog EnableStatus,
|
||||
sysMonLed EnableStatus,
|
||||
sysMonDefaults INTEGER
|
||||
}
|
||||
|
||||
sysMonIndicator OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
cpu-usage(1),
|
||||
ram-usage(2),
|
||||
power-supply(3),
|
||||
onboard-power(4),
|
||||
fan(5),
|
||||
temperature(6),
|
||||
laser(7)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enumeration."
|
||||
::= { sysMonConfigEntry 1 }
|
||||
|
||||
sysMonEnable OBJECT-TYPE
|
||||
SYNTAX EnableStatus
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enabled/disabled"
|
||||
::= { sysMonConfigEntry 2 }
|
||||
|
||||
sysMonPeriod OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Configure monitoring period in seconds."
|
||||
::= { sysMonConfigEntry 3 }
|
||||
|
||||
sysMonTrap OBJECT-TYPE
|
||||
SYNTAX EnableStatus
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enabled/disabled"
|
||||
::= { sysMonConfigEntry 4 }
|
||||
|
||||
sysMonLog OBJECT-TYPE
|
||||
SYNTAX EnableStatus
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enabled/disabled"
|
||||
::= { sysMonConfigEntry 5 }
|
||||
|
||||
sysMonLed OBJECT-TYPE
|
||||
SYNTAX EnableStatus
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enabled/disabled"
|
||||
::= { sysMonConfigEntry 6 }
|
||||
|
||||
sysMonDefaults OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
noop(0),
|
||||
reset(1)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"If set to 1, resets all configurations to defaults."
|
||||
DEFVAL { noop }
|
||||
::= { sysMonConfigEntry 7 }
|
||||
|
||||
---*******************************************************************
|
||||
--------------Conformance Information---------------------------------
|
||||
---*******************************************************************
|
||||
|
||||
sysMonMIBGroups OBJECT IDENTIFIER ::= { prvtSysMonConformance 2 }
|
||||
|
||||
|
||||
sysMonNotificationGroup NOTIFICATION-GROUP
|
||||
NOTIFICATIONS {
|
||||
cpuUtilizationExceeded,
|
||||
ramFreeSpaceExceeded,
|
||||
portErrorsExceeded,
|
||||
portsBroadcastExceeded,
|
||||
portsCRCErrExceeded,
|
||||
portsRuntsExceeded,
|
||||
portsOverSizeExceeded
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Private Notification Group."
|
||||
::= { sysMonMIBGroups 3 }
|
||||
|
||||
|
||||
END
|