@ -0,0 +1,718 @@
|
||||
-- *********************************************************************
|
||||
-- **
|
||||
-- ** BATM Advanced Communications.
|
||||
-- **
|
||||
-- *********************************************************************
|
||||
-- ** Filename: PRVT-SYS-MON-MIB.mib
|
||||
-- ** Project: T-Metro Switches.
|
||||
-- ** Purpose: Private MIB
|
||||
-- *********************************************************************
|
||||
-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
|
||||
-- WARNING:
|
||||
--
|
||||
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
|
||||
--
|
||||
-- This file is the property of BATM Advanced Communications and contains
|
||||
-- proprietary and confidential information. This file is made
|
||||
-- available to authorized BATM customers on the express
|
||||
-- condition that neither it, nor any of the information contained
|
||||
-- therein, shall be disclosed to third parties or be used for any
|
||||
-- purpose other than to replace, modify or upgrade firmware and/or
|
||||
-- software components of BATM manufactured equipment within the
|
||||
-- authorized customer's network, and that such transfer be
|
||||
-- completed in accordance with the instructions provided by
|
||||
-- BATM. Any other use is strictly prohibited.
|
||||
--
|
||||
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
|
||||
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
|
||||
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
|
||||
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
|
||||
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
|
||||
--
|
||||
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
|
||||
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
|
||||
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
|
||||
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
|
||||
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
|
||||
--
|
||||
-- ----------------------------------------------------------------------------
|
||||
|
||||
PRVT-SYS-MON-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
software
|
||||
FROM PRVT-SWITCH-MIB
|
||||
Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE,
|
||||
Unsigned32
|
||||
FROM SNMPv2-SMI
|
||||
TruthValue
|
||||
FROM SNMPv2-TC;
|
||||
|
||||
prvtSysMonMIB MODULE-IDENTITY
|
||||
LAST-UPDATED "201312120000Z"
|
||||
ORGANIZATION
|
||||
"BATM Advanced Communication"
|
||||
CONTACT-INFO
|
||||
"BATM/Telco Systems Support team
|
||||
Email:
|
||||
For North America: techsupport@telco.com
|
||||
For North Europe: support@batm.de, info@batm.de
|
||||
For the rest of the world: techsupport@telco.com"
|
||||
DESCRIPTION
|
||||
"Information for system resources"
|
||||
REVISION "201312120000Z"
|
||||
DESCRIPTION
|
||||
"add prvtSysMonDoorOpen table prvtSysMonDoorOpenTest notification."
|
||||
REVISION "200909040000Z"
|
||||
DESCRIPTION
|
||||
"Sync to internal implementation."
|
||||
::= { software 3 }
|
||||
|
||||
|
||||
prvtSysMonNotifications OBJECT IDENTIFIER
|
||||
::= { prvtSysMonMIB 0 }
|
||||
|
||||
prvtSysMonObjects OBJECT IDENTIFIER
|
||||
::= { prvtSysMonMIB 1 }
|
||||
|
||||
prvtSysMonCurrentCpuUsage OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Current CPU Utilization"
|
||||
::= { prvtSysMonObjects 1 }
|
||||
|
||||
prvtSysMonCurrentCpuTemperature OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Current CPU Temperature"
|
||||
::= { prvtSysMonObjects 2 }
|
||||
|
||||
prvtSysMonCurrentRamUsage OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Current RAM Utilization"
|
||||
::= { prvtSysMonObjects 3 }
|
||||
|
||||
prvtSysMonSelfTestExecuteNow OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..1)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"When this object is set to '1', command
|
||||
self-test execute-now. Setting the variable to '0'
|
||||
results in an 'inconsistentValue' error.
|
||||
Setting it to any other value has no effect.
|
||||
|
||||
When this object is read, the value '0' is returned."
|
||||
::= { prvtSysMonObjects 4 }
|
||||
|
||||
prvtSysMonCpuUsage OBJECT IDENTIFIER
|
||||
::= { prvtSysMonObjects 5 }
|
||||
|
||||
prvtSysMonCpuUsageShutdown OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Shutdown cpu usage test"
|
||||
::= { prvtSysMonCpuUsage 1 }
|
||||
|
||||
prvtSysMonCpuUsageLog OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Send log if test failed"
|
||||
::= { prvtSysMonCpuUsage 2 }
|
||||
|
||||
prvtSysMonCpuUsageLed OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enable led if test failed"
|
||||
::= { prvtSysMonCpuUsage 3 }
|
||||
|
||||
prvtSysMonCpuUsageTrap OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Send trap if test failed"
|
||||
::= { prvtSysMonCpuUsage 4 }
|
||||
|
||||
prvtSysMonCpuUsagePeriod OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (1..65535)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Test period in seconds"
|
||||
::= { prvtSysMonCpuUsage 5 }
|
||||
|
||||
prvtSysMonCpuUsageLowThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..100)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Low threshold"
|
||||
::= { prvtSysMonCpuUsage 6 }
|
||||
|
||||
prvtSysMonCpuUsageHighThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..100)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"High threshold"
|
||||
::= { prvtSysMonCpuUsage 7 }
|
||||
|
||||
prvtSysMonCpuUsageLastStatus OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Status"
|
||||
::= { prvtSysMonCpuUsage 8 }
|
||||
|
||||
prvtSysMonCPUTemperature OBJECT IDENTIFIER
|
||||
::= { prvtSysMonObjects 6 }
|
||||
|
||||
prvtSysMonCpuTemperatureShutdown OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Shutdown cpu usage test"
|
||||
::= { prvtSysMonCPUTemperature 1 }
|
||||
|
||||
prvtSysMonCpuTemperatureLog OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Send log if test failed"
|
||||
::= { prvtSysMonCPUTemperature 2 }
|
||||
|
||||
prvtSysMonCpuTemperatureLed OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enable led if test failed"
|
||||
::= { prvtSysMonCPUTemperature 3 }
|
||||
|
||||
prvtSysMonCpuTemperatureTrap OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Send trap if test failed"
|
||||
::= { prvtSysMonCPUTemperature 4 }
|
||||
|
||||
prvtSysMonCpuTemperaturePeriod OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (1..65535)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Test period in seconds"
|
||||
::= { prvtSysMonCPUTemperature 5 }
|
||||
|
||||
prvtSysMonCpuTemperatureLowThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32 (-40..100)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Low threshold"
|
||||
::= { prvtSysMonCPUTemperature 6 }
|
||||
|
||||
prvtSysMonCpuTemperatureHighThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32 (-40..100)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"High threshold"
|
||||
::= { prvtSysMonCPUTemperature 7 }
|
||||
|
||||
prvtSysMonCpuTemperatureLastStatus OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Status"
|
||||
::= { prvtSysMonCPUTemperature 8 }
|
||||
|
||||
prvtSysMonRAMUsage OBJECT IDENTIFIER
|
||||
::= { prvtSysMonObjects 7 }
|
||||
|
||||
prvtSysMonRamUsageShutdown OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Shutdown cpu usage test"
|
||||
::= { prvtSysMonRAMUsage 1 }
|
||||
|
||||
prvtSysMonRamUsageLog OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Send log if test failed"
|
||||
::= { prvtSysMonRAMUsage 2 }
|
||||
|
||||
prvtSysMonRamUsageLed OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enable led if test failed"
|
||||
::= { prvtSysMonRAMUsage 3 }
|
||||
|
||||
prvtSysMonRamUsageTrap OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Send trap if test failed"
|
||||
::= { prvtSysMonRAMUsage 4 }
|
||||
|
||||
prvtSysMonRamUsagePeriod OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (1..65535)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Test period in seconds"
|
||||
::= { prvtSysMonRAMUsage 5 }
|
||||
|
||||
prvtSysMonRamUsageLowThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..100)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Low threshold"
|
||||
::= { prvtSysMonRAMUsage 6 }
|
||||
|
||||
prvtSysMonRamUsageHighThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..100)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"High threshold"
|
||||
::= { prvtSysMonRAMUsage 7 }
|
||||
|
||||
prvtSysMonRamUsageLastStatus OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Status"
|
||||
::= { prvtSysMonRAMUsage 8 }
|
||||
|
||||
prvtSysMonPortStatistics OBJECT IDENTIFIER
|
||||
::= { prvtSysMonObjects 8 }
|
||||
|
||||
prvtSysMonPortStatisticsShutdown OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Shutdown cpu usage test"
|
||||
::= { prvtSysMonPortStatistics 1 }
|
||||
|
||||
prvtSysMonPortStatisticsLog OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Send log if test failed"
|
||||
::= { prvtSysMonPortStatistics 2 }
|
||||
|
||||
prvtSysMonPortStatisticsLed OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enable led if test failed"
|
||||
::= { prvtSysMonPortStatistics 3 }
|
||||
|
||||
prvtSysMonPortStatisticsTrap OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Send trap if test failed"
|
||||
::= { prvtSysMonPortStatistics 4 }
|
||||
|
||||
prvtSysMonPortStatisticsPeriod OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (1..65535)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Test period in seconds"
|
||||
::= { prvtSysMonPortStatistics 5 }
|
||||
|
||||
prvtSysMonPortStatisticsLowThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..100)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Low threshold"
|
||||
::= { prvtSysMonPortStatistics 6 }
|
||||
|
||||
prvtSysMonPortStatisticsHighThreshold OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..100)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"High threshold"
|
||||
::= { prvtSysMonPortStatistics 7 }
|
||||
|
||||
prvtSysMonPortStatisticsLastStatus OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Status"
|
||||
::= { prvtSysMonPortStatistics 8 }
|
||||
|
||||
prvtSysMonPortStatisticsLastFailedPorts OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Status"
|
||||
::= { prvtSysMonPortStatistics 9 }
|
||||
|
||||
prvtSysMonFan OBJECT IDENTIFIER
|
||||
::= { prvtSysMonObjects 9 }
|
||||
|
||||
prvtSysMonFanShutdown OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Shutdown cpu usage test"
|
||||
::= { prvtSysMonFan 1 }
|
||||
|
||||
prvtSysMonFanLog OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Send log if test failed"
|
||||
::= { prvtSysMonFan 2 }
|
||||
|
||||
prvtSysMonFanLed OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enable led if test failed"
|
||||
::= { prvtSysMonFan 3 }
|
||||
|
||||
prvtSysMonFanTrap OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Send trap if test failed"
|
||||
::= { prvtSysMonFan 4 }
|
||||
|
||||
prvtSysMonFanPeriod OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (1..65535)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Test period in seconds"
|
||||
::= { prvtSysMonFan 5 }
|
||||
|
||||
prvtSysMonFanLastStatus OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Status"
|
||||
::= { prvtSysMonFan 6 }
|
||||
|
||||
prvtSysMonOnboardPower OBJECT IDENTIFIER
|
||||
::= { prvtSysMonObjects 10 }
|
||||
|
||||
prvtSysMonOnboardPowerShutdown OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Shutdown cpu usage test"
|
||||
::= { prvtSysMonOnboardPower 1 }
|
||||
|
||||
prvtSysMonOnboardPowerLog OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Send log if test failed"
|
||||
::= { prvtSysMonOnboardPower 2 }
|
||||
|
||||
prvtSysMonOnboardPowerLed OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enable led if test failed"
|
||||
::= { prvtSysMonOnboardPower 3 }
|
||||
|
||||
prvtSysMonOnboardPowerTrap OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Send trap if test failed"
|
||||
::= { prvtSysMonOnboardPower 4 }
|
||||
|
||||
prvtSysMonOnboardPowerPeriod OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (1..65535)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Test period in seconds"
|
||||
::= { prvtSysMonOnboardPower 5 }
|
||||
|
||||
prvtSysMonOnboardPowerLastStatus OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Status"
|
||||
::= { prvtSysMonOnboardPower 6 }
|
||||
|
||||
prvtSysMonPowerSupply OBJECT IDENTIFIER
|
||||
::= { prvtSysMonObjects 11 }
|
||||
|
||||
prvtSysMonPowerSupplyShutdown OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Shutdown cpu usage test"
|
||||
::= { prvtSysMonPowerSupply 1 }
|
||||
|
||||
prvtSysMonPowerSupplyLog OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Send log if test failed"
|
||||
::= { prvtSysMonPowerSupply 2 }
|
||||
|
||||
prvtSysMonPowerSupplyLed OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enable led if test failed"
|
||||
::= { prvtSysMonPowerSupply 3 }
|
||||
|
||||
prvtSysMonPowerSupplyTrap OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Send trap if test failed"
|
||||
::= { prvtSysMonPowerSupply 4 }
|
||||
|
||||
prvtSysMonPowerSupplyPeriod OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (1..65535)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Test period in seconds"
|
||||
::= { prvtSysMonPowerSupply 5 }
|
||||
|
||||
prvtSysMonPowerSupplyLastStatus OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Status"
|
||||
::= { prvtSysMonPowerSupply 6 }
|
||||
|
||||
prvtSysMonPowerSupplyFan OBJECT IDENTIFIER
|
||||
::= { prvtSysMonObjects 12 }
|
||||
|
||||
prvtSysMonPowerSupplyFanShutdown OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Shutdown cpu usage test"
|
||||
::= { prvtSysMonPowerSupplyFan 1 }
|
||||
|
||||
prvtSysMonPowerSupplyFanLog OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Send log if test failed"
|
||||
::= { prvtSysMonPowerSupplyFan 2 }
|
||||
|
||||
prvtSysMonPowerSupplyFanLed OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enable led if test failed"
|
||||
::= { prvtSysMonPowerSupplyFan 3 }
|
||||
|
||||
prvtSysMonPowerSupplyFanTrap OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Send trap if test failed"
|
||||
::= { prvtSysMonPowerSupplyFan 4 }
|
||||
|
||||
prvtSysMonPowerSupplyFanPeriod OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (1..65535)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Test period in seconds"
|
||||
::= { prvtSysMonPowerSupplyFan 5 }
|
||||
|
||||
prvtSysMonPowerSupplyFanLastStatus OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Status"
|
||||
::= { prvtSysMonPowerSupplyFan 6 }
|
||||
|
||||
prvtSysMonDoorOpen OBJECT IDENTIFIER
|
||||
::= { prvtSysMonObjects 13 }
|
||||
|
||||
prvtSysMonDoorOpenShutdown OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Shutdown cpu usage test"
|
||||
::= { prvtSysMonDoorOpen 1 }
|
||||
|
||||
prvtSysMonDoorOpenLog OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Send log if test failed"
|
||||
::= { prvtSysMonDoorOpen 2 }
|
||||
|
||||
prvtSysMonDoorOpenLed OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enable led if test failed"
|
||||
::= { prvtSysMonDoorOpen 3 }
|
||||
|
||||
prvtSysMonDoorOpenTrap OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Send trap if test failed"
|
||||
::= { prvtSysMonDoorOpen 4 }
|
||||
|
||||
prvtSysMonDoorOpenPeriod OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (1..65535)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Test period in seconds"
|
||||
::= { prvtSysMonDoorOpen 5 }
|
||||
|
||||
prvtSysMonDoorOpenLastStatus OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Status"
|
||||
::= { prvtSysMonDoorOpen 6 }
|
||||
|
||||
prvtSysMonCpuUtilization NOTIFICATION-TYPE
|
||||
OBJECTS { prvtSysMonCurrentCpuUsage,
|
||||
prvtSysMonCpuUsageLowThreshold,
|
||||
prvtSysMonCpuUsageHighThreshold }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"CPU utilization test has passed the
|
||||
program threshold."
|
||||
::= { prvtSysMonNotifications 1 }
|
||||
|
||||
prvtSysMonRamUsage NOTIFICATION-TYPE
|
||||
OBJECTS { prvtSysMonCurrentRamUsage,
|
||||
prvtSysMonRamUsageLowThreshold,
|
||||
prvtSysMonRamUsageHighThreshold }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Memory utilization test has passed the
|
||||
program threshold."
|
||||
::= { prvtSysMonNotifications 2 }
|
||||
|
||||
prvtSysMonPowerSupplyTest NOTIFICATION-TYPE
|
||||
OBJECTS { prvtSysMonPowerSupplyLastStatus }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Result from power supply test has changed."
|
||||
::= { prvtSysMonNotifications 3 }
|
||||
|
||||
prvtSysMonFansTest NOTIFICATION-TYPE
|
||||
OBJECTS { prvtSysMonFanLastStatus }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Result from fan test has changed."
|
||||
::= { prvtSysMonNotifications 4 }
|
||||
|
||||
prvtSysMonCpuTemperature NOTIFICATION-TYPE
|
||||
OBJECTS { prvtSysMonCurrentCpuTemperature,
|
||||
prvtSysMonCpuTemperatureLowThreshold,
|
||||
prvtSysMonCpuTemperatureHighThreshold }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"CPU temperature test has passed the
|
||||
program threshold."
|
||||
::= { prvtSysMonNotifications 5 }
|
||||
|
||||
prvtSysMonPortStatisticsTest NOTIFICATION-TYPE
|
||||
OBJECTS { prvtSysMonPortStatisticsLastFailedPorts }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Result from port statistics test has changed."
|
||||
::= { prvtSysMonNotifications 6 }
|
||||
|
||||
prvtSysMonPowerSupplyFansTest NOTIFICATION-TYPE
|
||||
OBJECTS { prvtSysMonPowerSupplyFanLastStatus }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Result from power-supply-fan test has changed."
|
||||
::= { prvtSysMonNotifications 7 }
|
||||
|
||||
prvtSysMonOnBoardPowerSupplyTest NOTIFICATION-TYPE
|
||||
OBJECTS { prvtSysMonOnboardPowerLastStatus }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Result from onboard-power test has changed."
|
||||
::= { prvtSysMonNotifications 8 }
|
||||
|
||||
prvtSysMonDoorOpenTest NOTIFICATION-TYPE
|
||||
OBJECTS { prvtSysMonDoorOpenLastStatus }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Result from door-open test has changed."
|
||||
::= { prvtSysMonNotifications 9 }
|
||||
|
||||
END -- end of module PRVT-SYS-MON-MIB.
|