Initial commit
This commit is contained in:
523
MIBS/westmountainradio/RMCU
Normal file
523
MIBS/westmountainradio/RMCU
Normal file
@ -0,0 +1,523 @@
|
||||
-- MIB. Import this into your MIB Browser software.
|
||||
-- This is for West Mountain Radio RIGrunner 4005i
|
||||
|
||||
RMCU DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
--enterprises, IpAddress, Gauge, TimeTicks FROM RFC1155-SMI
|
||||
DisplayString FROM RFC1213-MIB
|
||||
OBJECT-TYPE FROM RFC-1212
|
||||
TEXTUAL-CONVENTION FROM SNMPv2-TC
|
||||
NOTIFICATION-TYPE, Gauge32, Integer32, enterprises, MODULE-IDENTITY FROM SNMPv2-SMI
|
||||
TRAP-TYPE FROM RFC-1215;
|
||||
|
||||
rr4005i MODULE-IDENTITY
|
||||
LAST-UPDATED "201710111300Z"
|
||||
ORGANIZATION "West Mountain Radio"
|
||||
CONTACT-INFO "www.westmountainradio.com"
|
||||
DESCRIPTION "West Mountain Radio RIGrunner 4005i"
|
||||
REVISION "201710111300Z"
|
||||
DESCRIPTION "Revision"
|
||||
::= { enterprises 15117 1 }
|
||||
|
||||
wmr OBJECT IDENTIFIER ::= { enterprises 15117 }
|
||||
|
||||
product OBJECT IDENTIFIER ::= { rr4005i 1 }
|
||||
control OBJECT IDENTIFIER ::= { rr4005i 2 }
|
||||
control-ints OBJECT IDENTIFIER ::= { rr4005i 4 }
|
||||
traps OBJECT IDENTIFIER ::= { rr4005i 3 }
|
||||
|
||||
-- ON-OFF ::= INTEGER { ON(1), OFF(0) }
|
||||
|
||||
FixedDiv1000 ::= TEXTUAL-CONVENTION
|
||||
DISPLAY-HINT "d-3"
|
||||
STATUS current
|
||||
DESCRIPTION "Fixed point, thousandths"
|
||||
SYNTAX Integer32
|
||||
|
||||
name OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Unit name"
|
||||
::= { product 1 }
|
||||
|
||||
|
||||
version OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Software and hardware version"
|
||||
::= { product 2 }
|
||||
|
||||
build-date OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Date of software was built"
|
||||
::= { product 3 }
|
||||
|
||||
|
||||
|
||||
analog1name OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Name of analog input #1"
|
||||
::= { control 1 }
|
||||
|
||||
analog1val OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Value of analog input #1"
|
||||
::= { control 2 }
|
||||
|
||||
analog2name OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Name of analog input #2"
|
||||
::= { control 3 }
|
||||
|
||||
analog2val OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Value of analog input #2"
|
||||
::= { control 4 }
|
||||
|
||||
analog3name OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Name of analog input #3"
|
||||
::= { control 5 }
|
||||
|
||||
analog3val OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Value of analog input #3"
|
||||
::= { control 6 }
|
||||
|
||||
analog4name OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Name of analog input #4"
|
||||
::= { control 7 }
|
||||
|
||||
analog4val OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Value of analog input #4"
|
||||
::= { control 8 }
|
||||
|
||||
analog5name OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Name of analog input #5"
|
||||
::= { control 9 }
|
||||
|
||||
analog5val OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Value of analog input #5"
|
||||
::= { control 10 }
|
||||
|
||||
analog6name OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Name of analog input #6"
|
||||
::= { control 11 }
|
||||
|
||||
analog6val OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Value of analog input #6"
|
||||
::= { control 12 }
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
digout1name OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Name of digital output #1"
|
||||
::= { control 65 }
|
||||
|
||||
digout1val OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Value of digital output #1"
|
||||
::= { control 66 }
|
||||
|
||||
digout2name OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Name of digital output #2"
|
||||
::= { control 67 }
|
||||
|
||||
digout2val OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Value of digital output #2"
|
||||
::= { control 68 }
|
||||
|
||||
digout3name OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Name of digital output #3"
|
||||
::= { control 69 }
|
||||
|
||||
digout3val OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Value of digital output #3"
|
||||
::= { control 70 }
|
||||
|
||||
digout4name OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Name of digital output #4"
|
||||
::= { control 71 }
|
||||
|
||||
digout4val OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Value of digital output #4"
|
||||
::= { control 72 }
|
||||
|
||||
digout5name OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Name of digital output #5"
|
||||
::= { control 73 }
|
||||
|
||||
digout5val OBJECT-TYPE
|
||||
SYNTAX INTEGER
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Value of digital output #5"
|
||||
::= { control 74 }
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
analog1val-int OBJECT-TYPE
|
||||
SYNTAX FixedDiv1000
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Value of analog input #1"
|
||||
::= { control-ints 1 }
|
||||
|
||||
analog2val-int OBJECT-TYPE
|
||||
SYNTAX FixedDiv1000
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Value of analog input #2"
|
||||
::= { control-ints 2 }
|
||||
|
||||
analog3val-int OBJECT-TYPE
|
||||
SYNTAX FixedDiv1000
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Value of analog input #3"
|
||||
::= { control-ints 3 }
|
||||
|
||||
analog4val-int OBJECT-TYPE
|
||||
SYNTAX FixedDiv1000
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Value of analog input #4"
|
||||
::= { control-ints 4 }
|
||||
|
||||
analog5val-int OBJECT-TYPE
|
||||
SYNTAX FixedDiv1000
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Value of analog input #5"
|
||||
::= { control-ints 5 }
|
||||
|
||||
analog6val-int OBJECT-TYPE
|
||||
SYNTAX FixedDiv1000
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Value of analog input #6"
|
||||
::= { control-ints 6 }
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
trap-auth NOTIFICATION-TYPE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap caused by authorization failure"
|
||||
::= {traps 1}
|
||||
|
||||
trap-analog-over1 NOTIFICATION-TYPE
|
||||
OBJECTS {name, analog1val}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap caused by analog input #1 being over threshold"
|
||||
::= {traps 2}
|
||||
|
||||
trap-analog-over2 NOTIFICATION-TYPE
|
||||
OBJECTS {name, analog2val}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap caused by analog input #2 being over threshold"
|
||||
::= {traps 3}
|
||||
|
||||
trap-analog-over3 NOTIFICATION-TYPE
|
||||
OBJECTS {name, analog3val}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap caused by analog input #3 being over threshold"
|
||||
::= {traps 4}
|
||||
|
||||
trap-analog-over4 NOTIFICATION-TYPE
|
||||
OBJECTS {name, analog4val}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap caused by analog input #4 being over threshold"
|
||||
::= {traps 5}
|
||||
|
||||
trap-analog-over5 NOTIFICATION-TYPE
|
||||
OBJECTS {name, analog5val}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap caused by analog input #5 being over threshold"
|
||||
::= {traps 6}
|
||||
|
||||
trap-analog-over6 NOTIFICATION-TYPE
|
||||
OBJECTS {name, analog6val}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap caused by analog input #6 being over threshold"
|
||||
::= {traps 7}
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
trap-analog-under6 NOTIFICATION-TYPE
|
||||
OBJECTS {name, analog6val}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap caused by analog input #6 being under threshold"
|
||||
::= {traps 23}
|
||||
|
||||
|
||||
trap-poweron NOTIFICATION-TYPE
|
||||
OBJECTS {name}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap caused by power-on"
|
||||
::= {traps 34}
|
||||
|
||||
|
||||
|
||||
|
||||
trap-test NOTIFICATION-TYPE
|
||||
OBJECTS {name}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap caused by user test"
|
||||
::= {traps 52}
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
trap-digout-inactive1 NOTIFICATION-TYPE
|
||||
OBJECTS {name}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap caused by digitout output #1 going inactive"
|
||||
::= {traps 72}
|
||||
|
||||
trap-digout-inactive2 NOTIFICATION-TYPE
|
||||
OBJECTS {name}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap caused by digitout output #2 going inactive"
|
||||
::= {traps 73}
|
||||
|
||||
trap-digout-inactive3 NOTIFICATION-TYPE
|
||||
OBJECTS {name}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap caused by digitout output #3 going inactive"
|
||||
::= {traps 74}
|
||||
|
||||
trap-digout-inactive4 NOTIFICATION-TYPE
|
||||
OBJECTS {name}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap caused by digitout output #4 going inactive"
|
||||
::= {traps 75}
|
||||
|
||||
trap-digout-inactive5 NOTIFICATION-TYPE
|
||||
OBJECTS {name}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap caused by digitout output #5 going inactive"
|
||||
::= {traps 76}
|
||||
|
||||
|
||||
|
||||
trap-digout-active1 NOTIFICATION-TYPE
|
||||
OBJECTS {name}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap caused by digitout output #1 going active"
|
||||
::= {traps 88}
|
||||
|
||||
trap-digout-active2 NOTIFICATION-TYPE
|
||||
OBJECTS {name}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap caused by digitout output #2 going active"
|
||||
::= {traps 89}
|
||||
|
||||
trap-digout-active3 NOTIFICATION-TYPE
|
||||
OBJECTS {name}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap caused by digitout output #3 going active"
|
||||
::= {traps 90}
|
||||
|
||||
trap-digout-active4 NOTIFICATION-TYPE
|
||||
OBJECTS {name}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap caused by digitout output #4 going active"
|
||||
::= {traps 91}
|
||||
|
||||
trap-digout-active5 NOTIFICATION-TYPE
|
||||
OBJECTS {name}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap caused by digitout output #5 going active"
|
||||
::= {traps 92}
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
trap-analog-urecover6 NOTIFICATION-TYPE
|
||||
OBJECTS {name, analog6val}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap caused by analog input #6 recovering from under alarm"
|
||||
::= {traps 109}
|
||||
|
||||
|
||||
trap-analog-orecover1 NOTIFICATION-TYPE
|
||||
OBJECTS {name, analog1val}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap caused by analog input #1 recovering from over alarm"
|
||||
::= {traps 120}
|
||||
|
||||
trap-analog-orecover2 NOTIFICATION-TYPE
|
||||
OBJECTS {name, analog2val}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap caused by analog input #2 recovering from over alarm"
|
||||
::= {traps 121}
|
||||
|
||||
trap-analog-orecover3 NOTIFICATION-TYPE
|
||||
OBJECTS {name, analog3val}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap caused by analog input #3 recovering from over alarm"
|
||||
::= {traps 122}
|
||||
|
||||
trap-analog-orecover4 NOTIFICATION-TYPE
|
||||
OBJECTS {name, analog4val}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap caused by analog input #4 recovering from over alarm"
|
||||
::= {traps 123}
|
||||
|
||||
trap-analog-orecover5 NOTIFICATION-TYPE
|
||||
OBJECTS {name, analog5val}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap caused by analog input #5 recovering from over alarm"
|
||||
::= {traps 124}
|
||||
|
||||
trap-analog-orecover6 NOTIFICATION-TYPE
|
||||
OBJECTS {name, analog6val}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap caused by analog input #6 recovering from over alarm"
|
||||
::= {traps 125}
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
END
|