-- This file was included in Ciena MIB release MIBS-CIENA-CES-08-07-00-024
--
-- CIENA-CES-NOTIFICATIONS-CONTROL-MIB.my
--
--

        CIENA-CES-NOTIFICATIONS-CONTROL DEFINITIONS ::= BEGIN

 IMPORTS
    OBJECT-TYPE, MODULE-IDENTITY
        FROM SNMPv2-SMI
    cienaCesNotificationsControlModule
        FROM CIENA-SMI
    CienaGlobalState
        FROM CIENA-TC;


 cienaCesNotificationsControlMIB MODULE-IDENTITY
              LAST-UPDATED "201706070000Z"
              ORGANIZATION "Ciena Corp."
              CONTACT-INFO
              "   Mib Meister
                  7035 Ridge Road
                  Hanover, Maryland 21076
                  USA
                  Phone:  +1 800 921 1144
                  Email:  support@ciena.com"
              DESCRIPTION
                        "This module defines the object identifiers to control the notification state for
                        each of the notification or set of notifications defined for CES."

                  REVISION
                        "201706070000Z"
              DESCRIPTION
                        "Updated contact info."

                  REVISION
                        "201610270000Z"
              DESCRIPTION
                       "Added cienaCesCommandFileCompletedTrapState and
                        cienaCesCommandFileFailedTrapState."

                  REVISION
                       "201610070000Z"
              DESCRIPTION
                       "Added  cienaCesXcvrUncertifiedTrapState at cienaCesNotificationsControl 73."
                  REVISION
                       "201603060000Z"
              DESCRIPTION
                       "Added  cienaCesDataplanePortShapingSubscriptionTrapState at cienaCesNotificationsControl 72."
                  REVISION
                        "201505060000Z"
              DESCRIPTION
                       "Added  cienaCesAlarmCutoffTrapState at cienaCesNotificationsControl 71."

                  REVISION
                        "201501070000Z"
              DESCRIPTION
                       "Added cienaCesSyncModuleSlotTrapState at cienaCesNotificationsControl 70."

                  REVISION
                        "201412100000Z"
              DESCRIPTION
                       "Added cienaCesSyncInputProtectionUnitTrapState at cienaCesNotificationsControl 68.
                        Added cienaCesSyncInputProtectionGroupTrapState at cienaCesNotificationsControl 69."

                  REVISION
                        "201402250000Z"
              DESCRIPTION
                       "Added cienaCesChassisUsbFlashEnableChangeTrapState at cienaCesNotificationsControl 66.
                        Added cienaCesChassisAirFilterTrapState at cienaCesNotificationsControl 67."

                  REVISION
                        "201312180000Z"
              DESCRIPTION
                       "Added cienaCesIOMStateChangeTrapState at cienaCesNotificationsControl 61.
                        Added cienaCesIOMBuzzerEnableChangeTrapState at cienaCesNotificationsControl 62.
                        Added cienaCesIOMBuzzerStateChangeTrapState at cienaCesNotificationsControl 63.
                        Added cienaCesIOMAlarmOutputStateChangeTrapState at cienaCesNotificationsControl 64.
                        Added cienaCesIOMAlarmInputStateChangeTrapState at cienaCesNotificationsControl 65."

                  REVISION
                        "201311050000Z"
              DESCRIPTION
                       "Added cienaCesCfmDelayVariationFaultTrapState."

                  REVISION
                        "201310280000Z"
              DESCRIPTION
                       "Added cienaCesCfmSyntheticLossNearFaultTrapState and cienaCesCfmSyntheticLossFarFaultTrapState
                        for controlling synthetic loss traps"

                  REVISION
                        "201103220000Z"
              DESCRIPTION
                       "Initial creation. This module defines the object identifiers to control
                       the notification state for each of the notification or set of notifications
                       defined for CES."
                        ::= { cienaCesNotificationsControlModule 1 }

cienaCesNotificationsControl    OBJECT IDENTIFIER ::= { cienaCesNotificationsControlMIB 1 }

--
-- Node definitions
--

--
-- Port related notification control
--

 cienaCesPortEnhancedLinkTrapState    OBJECT-TYPE
     SYNTAX           CienaGlobalState
     MAX-ACCESS       read-write
     STATUS           current
     DESCRIPTION
             "This object indicates whether the device generates enhanced port link up
              and down traps."
     DEFVAL { enabled }
     ::= { cienaCesNotificationsControl 1 }

  cienaCesPortStdLinkTrapState    OBJECT-TYPE
     SYNTAX           CienaGlobalState
     MAX-ACCESS       read-write
     STATUS           current
     DESCRIPTION
             "This object indicates whether the device generates standard port link up
              and down traps."
     DEFVAL { enabled }
     ::= { cienaCesNotificationsControl 2 }

  cienaCesPortAllTrapState                      OBJECT-TYPE
        SYNTAX                  CienaGlobalState
        MAX-ACCESS              read-write
        STATUS                  current
        DESCRIPTION
                "This object indicates whether the device generates any port related traps."
    DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 3 }

--
-- Equipment related notification control
--

 cienaCesModuleAllModulesTrapState              OBJECT-TYPE
        SYNTAX                  CienaGlobalState
        MAX-ACCESS              read-write
        STATUS                  current
        DESCRIPTION
                "This object indicates whether the device sends out module related traps."
    DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 6 }

 cienaCesModuleAllModulesHealthTrapState                OBJECT-TYPE
        SYNTAX                  CienaGlobalState
        MAX-ACCESS              read-write
        STATUS                  current
        DESCRIPTION
                "This object indicates whether the device sends out module health related traps."
    DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 7 }

 cienaCesModuleSensorTrapState          OBJECT-TYPE
        SYNTAX                  CienaGlobalState
        MAX-ACCESS              read-write
        STATUS                  current
        DESCRIPTION
                "This object indicates whether device sends out module sensor related traps."
    DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 8 }

 cienaCesModuleHATrapState              OBJECT-TYPE
        SYNTAX                  CienaGlobalState
        MAX-ACCESS              read-write
        STATUS                  current
        DESCRIPTION
                "This object indicates whether the device sends out the HA switchover trap."
    DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 9 }

 cienaCesModuleProtectionModeTrapState          OBJECT-TYPE
        SYNTAX                  CienaGlobalState
        MAX-ACCESS              read-write
        STATUS                  current
        DESCRIPTION
                "This object indicates whether the device sends out the protection mode
                 state change trap."
    DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 10 }

 cienaCesModulePOSTErrorTrapState               OBJECT-TYPE
        SYNTAX                  CienaGlobalState
        MAX-ACCESS              read-write
        STATUS                  current
        DESCRIPTION
                "This object indicates whether the device sends out the POST error trap."
    DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 11 }

 cienaCesModuleSwitchFabricDisruptedTrapState   OBJECT-TYPE
        SYNTAX                  CienaGlobalState
        MAX-ACCESS              read-write
        STATUS                  current
        DESCRIPTION
                "This object indicates whether the device sends out the switch fabric disrupted trap."
   DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 12 }

 cienaCesChassisAllPowerSupplyTrapState         OBJECT-TYPE
        SYNTAX                  CienaGlobalState
        MAX-ACCESS              read-write
        STATUS                  current
        DESCRIPTION
                "This object indicates whether the device sends out power-supply
                related traps."
    DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 14 }

 cienaCesChassisAllFanTrapState         OBJECT-TYPE
        SYNTAX                  CienaGlobalState
        MAX-ACCESS              read-write
        STATUS                  current
        DESCRIPTION
                "This object indicates whether the device sends out chassis fan related traps."
    DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 15 }

 cienaCesChassisAllFanTrayTrapState     OBJECT-TYPE
        SYNTAX                  CienaGlobalState
        MAX-ACCESS              read-write
        STATUS                  current
        DESCRIPTION
                "This object indicates whether the device sends out chassis fan tray related traps."
    DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 16 }

 cienaCesChassisAllFanTempTrapState     OBJECT-TYPE
        SYNTAX                  CienaGlobalState
        MAX-ACCESS              read-write
        STATUS                  current
        DESCRIPTION
                "This object indicates whether the device sends out chassis fan temperature
                related traps."
    DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 17 }

 cienaCesChassisHealthTrapState                 OBJECT-TYPE
        SYNTAX                  CienaGlobalState
        MAX-ACCESS              read-write
        STATUS                  current
        DESCRIPTION
                "This object indicates whether the device sends out chassis health related
                traps."
    DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 18 }

 --
 -- RAPS
 --
 cienaCesRapsAlarmTrapState             OBJECT-TYPE
        SYNTAX                  CienaGlobalState
        MAX-ACCESS              read-write
        STATUS                  current
        DESCRIPTION
                "This object indicates whether the device sends out RAPS alarm related
                traps."
    DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 19 }

 --
 -- MPLS
 --
 cienaCesMplsTrapState  OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        MPLS related traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 20 }

 --
 -- CFM Fault trap control
 --
 cienaCesCfmFaultTrapState OBJECT-TYPE
     SYNTAX       CienaGlobalState
     MAX-ACCESS   read-write
     STATUS       current
     DESCRIPTION
             "Setting this object to 'disabled' causes
              CFM fault traps to be suppressed."
     DEFVAL { enabled }
     ::= { cienaCesNotificationsControl 21 }

 cienaCesCfmDelayFaultTrapState         OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        CFM Y.1731 delay measurement traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 22 }

 cienaCesCfmJitterFaultTrapState        OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        CFM Y.1731 jitter measurement traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 23 }

 cienaCesCfmFrameLossNearFaultTrapState         OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        CFM Y.1731 frame-loss-near measurement traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 24 }

 cienaCesCfmFrameLossFarFaultTrapState  OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        CFM Y.1731 frame-loss-far measurement traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 25 }

   cienaCesCfmSyntheticLossNearFaultTrapState   OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        CFM Y.1731 synthetic-loss near fault and clear traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 26 }

   cienaCesCfmSyntheticLossFarFaultTrapState    OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        CFM Y.1731 synthetic-loss far fault and clear traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 27 }

 cienaCesPbtFaultTrapState      OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        PBB-TE related traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 28 }

 --
 -- BFD Fault trap control knob
 --
 cienaCesBfdTrapState OBJECT-TYPE
     SYNTAX       CienaGlobalState
     MAX-ACCESS   read-write
     STATUS       current
     DESCRIPTION
             "Setting this object to 'disabled' causes
              BFD related traps to be suppressed."
     DEFVAL { enabled }
     ::= { cienaCesNotificationsControl 29 }

--IP Interface
 cienaCesIPMgmtInterfaceAddrChangeTrapState     OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes the
                        IP address change trap to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 31 }

 cienaCesIPMgmtInterfaceGatewayAddrChangeTrapState      OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes the
                        IP Gateway change trap to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 32 }

 --Dataplane
 cienaCesDataplaneUcastTrapState        OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        dataplane unicast threshold exceed/normal traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 35 }

 cienaCesDataplaneBcastTrapState        OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        dataplane broadcast threshold exceed/normal traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 36 }

 cienaCesDataplaneMcastTrapState        OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' will cause
                        dataplane multicast threshold exceed/normal traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 37 }

 cienaCesPortXcvrLinkStateChangeTrapState       OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        port transceiver link state change traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 40 }

 cienaCesPortXcvrErrorTrapState         OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        port transceiver error traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 41 }

 cienaCesPortXcvrTempChangeTrapState    OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        port transceiver temperature change traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 42 }

   cienaCesPortXcvrVoltageChangeTrapState       OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        port transceiver voltage change traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 43 }

 cienaCesPortXcvrBiasChangeTrapState    OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        port transceiver bias change traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 44 }

 cienaCesPortXcvrTxPowerChangeTrapState         OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        port transceiver TX power change traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 45 }

 cienaCesPortXcvrRxPowerChangeTrapState         OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        port transceiver RX power change traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 46 }

 cienaCesPortXcvrSpeedInfoTrapState     OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        port transceiver speed information missing traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 47 }

 cienaCesRstpPortBackupTrapState        OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' cause
                        cienaCesRstpPortBackupNotification traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 48 }

 cienaCesRstpPortPvstBPduReceivedTrapState      OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' cause
                        cienaCesRstpPvstBpduReceivedNotification traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 49 }

 cienaCesRstpPortSelfLoopTrapState      OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        cienaCesRstpSelfLoopNotification traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 50 }

 cienaCesRstpPortOperEdgeTrapState      OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        cienaCesRstpPortOperEdgeNotification traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 51 }

 cienaCesRstpPortFlapTrapState  OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        cienaCesRstpPortFlapNotification traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 52 }

 cienaCesRstpBridgeRootPortLostTrapState        OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        cienaCesRstpBridgeRootPortLostNotification traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 53 }

 cienaCesFeatureLicenseStatusTrapState  OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        cienaCesPremiumFeatureLicenseNotInstalledNotification and
                         cienaCesPremiumFeatureLicensePartialStatusNotification traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 54 }

 cienaCesFeatureLicenseInstallErrorTrapState    OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        cienaCesPremiumFeatureLicenseInstallErrorNotification traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 55 }

 cienaCesFileTransferCompletionTrapState        OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        cienaCesFTransferCompletion traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 56 }

 cienaCesSwXgradeCompletionTrapState    OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        cienaCesSwXgradeCompletion traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 57 }

 cienaCesSystemConfigImproperCmdTrapState       OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        cienaCesImproperCmdInConfigFile traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 58 }

 cienaCesOamLinkEventTrapState  OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        cienaCesOamLinkEventTrap traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 59 }

 --
 -- CFM Fault trap control continued
 --
 cienaCesCfmDelayVariationFaultTrapState        OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
                        "Setting this object to 'disabled' causes
                        CFM Y.1731 Delay Variation measurement traps to be suppressed."
        DEFVAL { enabled }
        ::= { cienaCesNotificationsControl 60 }


 --
 -- Chassis IOM trap control
 --
 cienaCesIOMStateChangeTrapState  OBJECT-TYPE
      SYNTAX            CienaGlobalState
      MAX-ACCESS        read-write
      STATUS            current
      DESCRIPTION
         "Setting this object to 'disabled' causes
          cienaCesChassisIOMStateChangeNotification traps to be suppressed."
      DEFVAL { enabled }
      ::= { cienaCesNotificationsControl 61 }

 cienaCesIOMBuzzerEnableChangeTrapState  OBJECT-TYPE
      SYNTAX            CienaGlobalState
      MAX-ACCESS        read-write
      STATUS            current
      DESCRIPTION
         "Setting this object to 'disabled' causes
          cienaCesChassisIOMBuzzerEnableChangeNotification traps to be suppressed."
      DEFVAL { enabled }
      ::= { cienaCesNotificationsControl 62 }

 cienaCesIOMBuzzerStateChangeTrapState  OBJECT-TYPE
      SYNTAX            CienaGlobalState
      MAX-ACCESS        read-write
      STATUS            current
      DESCRIPTION
         "Setting this object to 'disabled' causes
          cienaCesChassisIOMBuzzerStateChangeNotification traps to be suppressed."
      DEFVAL { enabled }
      ::= { cienaCesNotificationsControl 63 }

 cienaCesIOMAlarmOutputStateChangeTrapState  OBJECT-TYPE
      SYNTAX            CienaGlobalState
      MAX-ACCESS        read-write
      STATUS            current
      DESCRIPTION
         "Setting this object to 'disabled' causes
          cienaCesChassisIOMAlarmOutputStateChangeNotification traps to be suppressed."
      DEFVAL { enabled }
      ::= { cienaCesNotificationsControl 64 }

 cienaCesIOMAlarmInputStateChangeTrapState  OBJECT-TYPE
      SYNTAX            CienaGlobalState
      MAX-ACCESS        read-write
      STATUS            current
      DESCRIPTION
         "Setting this object to 'disabled' causes
          cienaCesChassisIOMAlarmInputStateChangeNotification traps to be suppressed."
      DEFVAL { enabled }
      ::= { cienaCesNotificationsControl 65 }


 --
 -- USB Flash trap control
 --
 cienaCesChassisUsbFlashEnableChangeTrapState  OBJECT-TYPE
      SYNTAX            CienaGlobalState
      MAX-ACCESS        read-write
      STATUS            current
      DESCRIPTION
         "Setting this object to 'disabled' causes
          cienaCesChassisUsbEnabledNotification and
          cienaCesChassisUsbDisabledNotification traps to be suppressed."
      DEFVAL { enabled }
      ::= { cienaCesNotificationsControl 66 }

 --
 -- Air Filter trap control
 --
 cienaCesChassisAirFilterTrapState  OBJECT-TYPE
      SYNTAX            CienaGlobalState
      MAX-ACCESS        read-write
      STATUS            current
      DESCRIPTION
         "Setting this object to 'disabled' causes
          cienaCesChassisAirFilterServiceNotification traps to be suppressed."
      DEFVAL { enabled }
      ::= { cienaCesNotificationsControl 67 }

 --
 -- Sync Input Protection Unit trap control
 --
 cienaCesSyncInputProtectionUnitTrapState  OBJECT-TYPE
      SYNTAX            CienaGlobalState
      MAX-ACCESS        read-write
      STATUS            current
      DESCRIPTION
         "Setting this object to 'disabled' causes
          cienaCesSyncInputPUStateChangeNotification traps to be suppressed."
      DEFVAL { enabled }
      ::= { cienaCesNotificationsControl 68 }

 --
 -- Sync Input Protection Group trap control
 --
 cienaCesSyncInputProtectionGroupTrapState  OBJECT-TYPE
      SYNTAX            CienaGlobalState
      MAX-ACCESS        read-write
      STATUS            current
      DESCRIPTION
         "Setting this object to 'disabled' causes
          cienaCesSyncInputProtGroupStateChangeNotification traps to be suppressed."
      DEFVAL { enabled }
      ::= { cienaCesNotificationsControl 69 }

 --
 -- Sync Module Slot trap control
 --
 cienaCesSyncModuleSlotTrapState  OBJECT-TYPE
      SYNTAX            CienaGlobalState
      MAX-ACCESS        read-write
      STATUS            current
      DESCRIPTION
         "Setting this object to 'disabled' causes
          cienaCesSyncModuleSlotStateChangeNotification traps to be suppressed."
      DEFVAL { enabled }
      ::= { cienaCesNotificationsControl 70 }

 --
 -- Alarm Cutoff trap control
 --
 cienaCesChassisAlarmCutoffTrapState  OBJECT-TYPE
      SYNTAX            CienaGlobalState
      MAX-ACCESS        read-write
      STATUS            current
      DESCRIPTION
         "Setting this object to 'disabled' causes
          cienaCesChassisAlarmCutoffNotification traps to be suppressed."
      DEFVAL { enabled }
      ::= { cienaCesNotificationsControl 71 }

 cienaCesDataplanePortShapingSubscriptionTrapState        OBJECT-TYPE
      SYNTAX          CienaGlobalState
      MAX-ACCESS      read-write
      STATUS          current
      DESCRIPTION
         "Setting this object to 'disabled' causes
          dataplane cienaCesDpPortShapingSubscriptionExceedsOperSpeed and
          cienaCesDpPortShapingSubscriptionWithinOperSpeed traps to be suppressed."
      DEFVAL { enabled }
      ::= { cienaCesNotificationsControl 72 }

 cienaCesPortXcvrUncertifiedTrapState     OBJECT-TYPE
        SYNTAX          CienaGlobalState
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
           "Setting this object to 'enabled' enables generation of 
            cienaCesPortXcvrUncertifiedNotification traps."
        DEFVAL { disabled }
        ::= { cienaCesNotificationsControl 73 }

 --
 -- Command File Complete trap control
 --
 cienaCesCommandFileCompletedTrapState  OBJECT-TYPE
      SYNTAX          CienaGlobalState
      MAX-ACCESS      read-write
      STATUS          current
      DESCRIPTION
         "Setting this object to 'disabled' causes
          cienaCesCommandFileCompletedNotification traps to be
          suppressed."
      DEFVAL { enabled }
      ::= { cienaCesNotificationsControl 74 }

 cienaCesCommandFileFailedTrapState     OBJECT-TYPE
      SYNTAX          CienaGlobalState
      MAX-ACCESS      read-write
      STATUS          current
      DESCRIPTION
         "Setting this object to 'disabled' causes
          cienaCesCommandFileFailedNotification traps to be
          suppressed."
      DEFVAL { enabled }
      ::= { cienaCesNotificationsControl 75 }

  END