APRISAXE-MIB-4RF DEFINITIONS ::= BEGIN -- -- File: $Id: 4RF-APRISAXE-MIB.txt,v 1.148.2.1 2007/09/17 01:31:14 di Exp $ -- -- Copyright: 2004 4RF COMMUNICATIONS LTD -- -- Description: -- MIB for AprisaXE project. -- -- Versions: -- -- Release 3 -- Added support for 4-wire cards and configurable cross-connections -- -- Notes: -- None -- IMPORTS -- Standard imports MODULE-IDENTITY, OBJECT-TYPE, OBJECT-IDENTITY, NOTIFICATION-TYPE, Integer32, Unsigned32, Counter32, IpAddress FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF -- 4RF Specific imports fourRFAprisaXE FROM PRODUCTS-MIB-4RF FourRFAlarmStatus, FourRFAlarmSeverity, FourRFAlarmEnabled, FourRFAlarmPresent, FourRFImageVersion, FourRFHardwareVersion, FourRFSerialNumber, FourRFChannelWidth, FourRFRSSI, FourRFModulationType, FourRFErrorCounter, FourRFFanStatus, FourRFTemperature, FourRFFrequency, FourRFTxPower, FourRFRfBand, FourRFSNR, FourRFClockSource, FourRFNetworkClockSelect, FourRFLoopback, FourRFNetworkClockStatus, FourRFMHSBStatus, FourRFMHSBCommand, FourRFProcessResultType FROM COMMON-TC-4RF AprisaXESlotNumber, AprisaXECardType, AprisaXEAlarmSource, AprisaXEPortNumber, AprisaXEAlarmMapping, AprisaXEAdcVoltage,AprisaXEDbValue, AprisaXEIQData, AprisaXEAlarmType, AprisaXEChannelControlType, AprisaXETdmPortType, AprisaXEHardwareVersion, AprisaXEDataStatus, AprisaXEQuadJetTrafficType, AprisaXEAlarmPolarity, AprisaXEAlarmOutput, AprisaXEQuadJetLineEncoding, AprisaXE4WRxGain, AprisaXE4WTxGain, AprisaXE4WInputLevel, AprisaXE4WOutputLevel, AprisaXEFXOInputLevel, AprisaXEFXOOutputLevel, AprisaXEFXSInputLevel, AprisaXEFXSOutputLevel, AprisaXEFXSPathMute, AprisaXESignalState, AprisaXETdmBus,AprisaXEPcmLaw,AprisaXEFXOCountry, AprisaXEAdpcmCompression,AprisaXEFXSPMLevel, AprisaXEInterfaceCnxnType,AprisaXEConnectionID, AprisaXEPcmMode,AprisaXESerialEquipmentMode, AprisaXEQuadJetConnectionType, AprisaXEHssSerialMode, AprisaXE2WireSignalState, AprisaXEEthernetPortNumber, AprisaXEEthernetGroup, AprisaXEEthernetFrameRate, AprisaXEEthernetPortPriority, AprisaXEEthernetGrouping, AprisaXEEthernetPrioQueueScheduling, AprisaXEEthernetPrioQueueMapping, AprisaXEDefaultAction, AprisaXEQuadJetLoopbacks, AprisaXEQuadJetWaveFormShapers, AprisaXECCActivationStatus, AprisaXEQuadJetMultiframeEnable, AprisaXEPSCActiveRadio, AprisaXEPSCActiveTx FROM APRISAXE-TC-4RF fourRFModules FROM MIB-4RF; -- Module Identification fourRFAprisaXEModule MODULE-IDENTITY LAST-UPDATED "200704300000Z" ORGANIZATION "www.4rf.com" CONTACT-INFO "postal: 4RF Communications Ltd 26 Glover Street Ngauranga PO Box 13-506 Wellington 6032 New Zealand phone: +64 4 499 6000 email: support@4rf.com" DESCRIPTION "MIB for the AprisaXE project" -- Revision history -- (in reverse chronological order) REVISION "200704300000Z" DESCRIPTION "Second draft" REVISION "200412090304Z" DESCRIPTION "First draft" ::= { fourRFModules 5 } aprisaXEConfig OBJECT-IDENTITY STATUS current DESCRIPTION "The root of the OID sub-tree for the AprisaXE product configuration." ::= { fourRFAprisaXE 1 } aprisaXEGroups OBJECT-IDENTITY STATUS current DESCRIPTION "The root of the OID sub-tree for the AprisaXE object groups." ::= { aprisaXEConfig 1 } aprisaXEObjects OBJECT-IDENTITY STATUS current DESCRIPTION "The root of the OID sub-tree for the AprisaXE product objects." ::= { aprisaXEConfig 2 } aprisaXEEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The root of the OID sub-tree for the AprisaXE product events." ::= { aprisaXEConfig 3 } aprisaXEEventsV2 OBJECT-IDENTITY STATUS current DESCRIPTION "The AprisaXE product events, ensures SNMPv1 compatibility." ::= { aprisaXEEvents 0 } aprisaXETestObjects OBJECT-IDENTITY STATUS current DESCRIPTION "The root of the OID sub-tree for the AprisaXE test objects." ::= { aprisaXEConfig 4 } -- *************************************************************************** -- Terminal Settings -- -- This object group provides access to basic terminal information such as the -- Rx and Tx frequencies. This is a product specific enhancement to the common -- terminalGroup defined in the COMMON-4RF MIB. -- *************************************************************************** aprisaXETerminal OBJECT IDENTIFIER ::= { aprisaXEObjects 1 } aprisaXETerminalRfChannelWidth OBJECT-TYPE SYNTAX FourRFChannelWidth MAX-ACCESS read-write STATUS current DESCRIPTION "The terminal RF channel width, the options are: 20kHz, 25kHz, 50kHz, 75kHz, 100kHz, 125kHz, 150kHz, 200kHz, 250kHz, 400kHz, 500kHz, 800kHz, 1MHz, 1.25MHz, 1.75MHz, 2MHz, 3.5MHz, 7MHz" ::= { aprisaXETerminal 4 } aprisaXETerminalRSSI OBJECT-TYPE SYNTAX FourRFRSSI MAX-ACCESS read-only STATUS current DESCRIPTION "The terminal RSSI in dBm." ::= { aprisaXETerminal 5 } aprisaXETerminalModulationState OBJECT-TYPE SYNTAX FourRFModulationType MAX-ACCESS read-write STATUS current DESCRIPTION "The terminal modulation state." ::= { aprisaXETerminal 6 } aprisaXETerminalClockReference OBJECT-TYPE SYNTAX INTEGER { automatic (0), manual (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The terminal clock reference configuration: automatic - manual - " ::= { aprisaXETerminal 7 } aprisaXETerminalClockSource OBJECT-TYPE SYNTAX FourRFClockSource MAX-ACCESS read-write STATUS current DESCRIPTION "The terminal clock source configuration: network - clocking is recovered from the synchronous network to which the terminal is connected. link - clocking is recovered from the remote end of the link. internal - the clock is generated internally. The clock reference must be in manual mode for this to take effect." ::= { aprisaXETerminal 8 } aprisaXETerminalAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The terminal alarm status, this reflects the overall status of the terminal. This will match the colour of the front panel control LED. The states used are noAlarm, minorAlarm and majorAlarm." ::= { aprisaXETerminal 9 } aprisaXETerminalRxAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The terminal alarm status, this reflects the overall RX status of the terminal. This will match the colour of the front panel RX LED. The states used are noAlarm, minorAlarm and majorAlarm." ::= { aprisaXETerminal 10 } aprisaXETerminalTxAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The terminal alarm status, this reflects the overall TX status of the terminal. This will match the colour of the front panel TX LED. The states used are noAlarm, minorAlarm and majorAlarm." ::= { aprisaXETerminal 11 } aprisaXETerminalBandwidth OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This returns the total bandwidth available over the link in kbps." ::= { aprisaXETerminal 12 } aprisaXEMotherboardSerialNumber OBJECT-TYPE SYNTAX FourRFSerialNumber MAX-ACCESS read-only STATUS current DESCRIPTION "The unique serial number for the motherboard." ::= { aprisaXETerminal 13 } aprisaXETerminalAllocatedBandwidth OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This returns the total bandwidth allocated over the link in kbps." ::= { aprisaXETerminal 14 } aprisaXETerminalLoopbackBandwidth OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This returns the total loopback bandwidth allocated in kbps." ::= { aprisaXETerminal 15 } aprisaXETerminalNetworkClockPrimaryStatus OBJECT-TYPE SYNTAX FourRFNetworkClockStatus MAX-ACCESS read-only STATUS current DESCRIPTION "This returns the status of the network clock primary source." ::= { aprisaXETerminal 16 } aprisaXETerminalNetworkClockSecondaryStatus OBJECT-TYPE SYNTAX FourRFNetworkClockStatus MAX-ACCESS read-only STATUS current DESCRIPTION "This returns the status of the network clock secondary source." ::= { aprisaXETerminal 17 } aprisaXETerminalNetworkClockCommand OBJECT-TYPE SYNTAX INTEGER { none (0), makePrimaryActive (1), makeSecondaryActive (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Forces a change in the active network clock." ::= { aprisaXETerminal 18} aprisaXETerminalStartupComplete OBJECT-TYPE SYNTAX INTEGER { notComplete (0), startupComplete (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the terminal startup sequence is complete." ::= { aprisaXETerminal 19 } aprisaXETerminalImageAlarmClear OBJECT-TYPE SYNTAX INTEGER { noCommand (0), clearAlternateImageAlarm (1), clearDefaultImageAlarm (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether the terminal startup sequence is complete." ::= { aprisaXETerminal 20 } aprisaXETerminalMuxStatus OBJECT-TYPE SYNTAX INTEGER { none (0), muxOnly (1) } MAX-ACCESS read-only STATUS obsolete DESCRIPTION "This indicates if the terminal is operating in Mux mode." ::= { aprisaXETerminal 21 } aprisaXETerminalBootloaderDataVersion OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This indicates the data version of the shared data field in the bootloader." ::= { aprisaXETerminal 22 } aprisaXETerminalUploadFailAlarmClear OBJECT-TYPE SYNTAX INTEGER { noCommand (0), clearUploadFailAlarm (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to clear a current Upload Failure Alarm." ::= { aprisaXETerminal 23 } aprisaXETerminalEquipmentType OBJECT-TYPE SYNTAX INTEGER { axeUnknown (0), axeRadio (1), axeMux (2), axeProtSwitch (3), axeProtRadio (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This indicates what type of equipment the terminal is." ::= { aprisaXETerminal 24 } aprisaXETerminalGroup OBJECT-GROUP OBJECTS { aprisaXETerminalRfChannelWidth, aprisaXETerminalRSSI, aprisaXETerminalModulationState, aprisaXETerminalClockReference, aprisaXETerminalClockSource, aprisaXETerminalAlarmStatus, aprisaXETerminalRxAlarmStatus, aprisaXETerminalTxAlarmStatus, aprisaXETerminalBandwidth, aprisaXEMotherboardSerialNumber, aprisaXETerminalAllocatedBandwidth, aprisaXETerminalLoopbackBandwidth, aprisaXETerminalNetworkClockPrimaryStatus, aprisaXETerminalNetworkClockSecondaryStatus, aprisaXETerminalNetworkClockCommand, aprisaXETerminalStartupComplete, aprisaXETerminalImageAlarmClear, aprisaXETerminalMuxStatus, aprisaXETerminalBootloaderDataVersion, aprisaXETerminalUploadFailAlarmClear, aprisaXETerminalEquipmentType } STATUS current DESCRIPTION "The AprisaXE terminal settings group." ::= { aprisaXEGroups 1 } -- *************************************************************************** -- End Terminal Settings -- *************************************************************************** -- *************************************************************************** -- Terminal performance information -- -- This section provides basic performance statistics for the terminal. -- *************************************************************************** aprisaXEPerformance OBJECT IDENTIFIER ::= { aprisaXEObjects 6 } aprisaXECorrectableErrorCount OBJECT-TYPE SYNTAX FourRFErrorCounter MAX-ACCESS read-only STATUS current DESCRIPTION "The terminal correctable error count." ::= { aprisaXEPerformance 1 } aprisaXEUncorrectableErrorCount OBJECT-TYPE SYNTAX FourRFErrorCounter MAX-ACCESS read-only STATUS current DESCRIPTION "The terminal uncorrectable error count." ::= { aprisaXEPerformance 2 } aprisaXEModemSNR OBJECT-TYPE SYNTAX FourRFSNR MAX-ACCESS read-only STATUS current DESCRIPTION "The modem signal to noise ratio." ::= { aprisaXEPerformance 3 } aprisaXETxPacketCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The terminal transmitted ethernet packet count (to link)." ::= { aprisaXEPerformance 4 } aprisaXERxPacketCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The terminal received ethernet packet count (from link)." ::= { aprisaXEPerformance 5 } aprisaXERxPacketErrorCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The terminal received ethernet packet error count (from link)." ::= { aprisaXEPerformance 6 } aprisaXEErrorCounterCommand OBJECT-TYPE SYNTAX INTEGER { countersRunning (0), resetCounters (1), freezeCounters (2), unfreezeCounters (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Forces reset, freeze or unfreeze the error counters." ::= { aprisaXEPerformance 7 } aprisaXEErrorFreeSeconds OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Error Free Seconds for the terminal." ::= { aprisaXEPerformance 8 } aprisaXEErroredSeconds OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Errored Seconds for the terminal." ::= { aprisaXEPerformance 9 } aprisaXEBERExponent OBJECT-TYPE SYNTAX DisplayString ( SIZE (0..64) ) MAX-ACCESS read-only STATUS current DESCRIPTION "The exponent of the Bit Error Rate for the terminal." ::= { aprisaXEPerformance 10 } aprisaXEPscSysUncorrectableErrorCount OBJECT-TYPE SYNTAX DisplayString ( SIZE (0..64) ) MAX-ACCESS read-only STATUS current DESCRIPTION "The terminal uncorrectable error count." ::= { aprisaXEPerformance 11 } aprisaXEPscSysErrorFreeSeconds OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Error Free Seconds for the terminal." ::= { aprisaXEPerformance 12 } aprisaXEPscSysErroredSeconds OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Errored Seconds for the terminal." ::= { aprisaXEPerformance 13 } aprisaXEPscSysBERExponent OBJECT-TYPE SYNTAX DisplayString( SIZE(0..64) ) MAX-ACCESS read-only STATUS current DESCRIPTION "The exponent of the Bit Error Rate for the terminal." ::= { aprisaXEPerformance 14 } aprisaXEPscRadioAUncorrectableErrorCount OBJECT-TYPE SYNTAX FourRFErrorCounter MAX-ACCESS read-only STATUS current DESCRIPTION "The terminal uncorrectable error count." ::= { aprisaXEPerformance 15 } aprisaXEPscRadioAErrorFreeSeconds OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Error Free Seconds for the terminal." ::= { aprisaXEPerformance 16 } aprisaXEPscRadioAErroredSeconds OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Errored Seconds for the terminal." ::= { aprisaXEPerformance 17 } aprisaXEPscRadioABERExponent OBJECT-TYPE SYNTAX DisplayString( SIZE(0..64) ) MAX-ACCESS read-only STATUS current DESCRIPTION "The exponent of the Bit Error Rate for the terminal." ::= { aprisaXEPerformance 18 } aprisaXEPscRadioBUncorrectableErrorCount OBJECT-TYPE SYNTAX FourRFErrorCounter MAX-ACCESS read-only STATUS current DESCRIPTION "The terminal uncorrectable error count." ::= { aprisaXEPerformance 19 } aprisaXEPscRadioBErrorFreeSeconds OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Error Free Seconds for the terminal." ::= { aprisaXEPerformance 20 } aprisaXEPscRadioBErroredSeconds OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Errored Seconds for the terminal." ::= { aprisaXEPerformance 21 } aprisaXEPscRadioBBERExponent OBJECT-TYPE SYNTAX DisplayString( SIZE(0..64) ) MAX-ACCESS read-only STATUS current DESCRIPTION "The exponent of the Bit Error Rate for the terminal." ::= { aprisaXEPerformance 22 } aprisaXEPerformanceGroup OBJECT-GROUP OBJECTS { aprisaXECorrectableErrorCount, aprisaXEUncorrectableErrorCount, aprisaXEModemSNR, aprisaXETxPacketCount, aprisaXERxPacketCount, aprisaXERxPacketErrorCount, aprisaXEErrorCounterCommand, aprisaXEErrorFreeSeconds, aprisaXEErroredSeconds, aprisaXEBERExponent, aprisaXEPscSysUncorrectableErrorCount, aprisaXEPscSysErrorFreeSeconds, aprisaXEPscSysErroredSeconds, aprisaXEPscSysBERExponent, aprisaXEPscRadioAUncorrectableErrorCount, aprisaXEPscRadioAErrorFreeSeconds, aprisaXEPscRadioAErroredSeconds, aprisaXEPscRadioABERExponent, aprisaXEPscRadioBUncorrectableErrorCount, aprisaXEPscRadioBErrorFreeSeconds, aprisaXEPscRadioBErroredSeconds, aprisaXEPscRadioBBERExponent } STATUS current DESCRIPTION "The AprisaXE terminal performance group." ::= { aprisaXEGroups 6 } -- *************************************************************************** -- End Performance -- *************************************************************************** -- *************************************************************************** -- External Alarms -- -- This section specifies the MIB attributes for handling external alarm -- inputs and outputs. For AprisaXE there are two external alarm inputs -- and four external alarm outputs. Two of the external alarm outputs will -- be used to reflect the alarm state of the remote terminal, one for major -- and one for minor alarms. -- -- The alarms can be enabled and disabled and the severity associated with -- the inputs can be set. The polarity indicating an alarm can also be set. -- *************************************************************************** aprisaXEExternalAlarms OBJECT IDENTIFIER ::= { aprisaXEObjects 11 } -- The first external alarm input aprisaXEExternalAlarm1 OBJECT IDENTIFIER ::= { aprisaXEExternalAlarms 1 } aprisaXEExternalAlarm1Status OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the first external alarm input." ::= { aprisaXEExternalAlarm1 1 } aprisaXEExternalAlarm1Severity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-write STATUS current DESCRIPTION "The severity of the first external alarm input." ::= { aprisaXEExternalAlarm1 2 } aprisaXEExternalAlarm1Enabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether the first external alarm input is enabled. If not changes to the input will be ignored. By default the alarm is enabled." ::= { aprisaXEExternalAlarm1 3 } aprisaXEExternalAlarm1Mapping OBJECT-TYPE SYNTAX AprisaXEAlarmMapping MAX-ACCESS read-write STATUS current DESCRIPTION "This defines how the first external alarm input is mapped to the remote alarms." ::= { aprisaXEExternalAlarm1 4 } aprisaXEExternalAlarm1Description OBJECT-TYPE SYNTAX DisplayString ( SIZE (0..64) ) MAX-ACCESS read-write STATUS current DESCRIPTION "A description (user defined) for the external alarm." ::= { aprisaXEExternalAlarm1 5 } aprisaXEExternalAlarm1Group OBJECT-GROUP OBJECTS { aprisaXEExternalAlarm1Status, aprisaXEExternalAlarm1Severity, aprisaXEExternalAlarm1Enabled, aprisaXEExternalAlarm1Mapping, aprisaXEExternalAlarm1Description } STATUS current DESCRIPTION "The AprisaXE first external alarm input group." ::= { aprisaXEGroups 11 } -- The second external alarm input aprisaXEExternalAlarm2 OBJECT IDENTIFIER ::= { aprisaXEExternalAlarms 2 } aprisaXEExternalAlarm2Status OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the second external alarm input." ::= { aprisaXEExternalAlarm2 1 } aprisaXEExternalAlarm2Severity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-write STATUS current DESCRIPTION "The severity of the second external alarm input." ::= { aprisaXEExternalAlarm2 2 } aprisaXEExternalAlarm2Enabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether the second external alarm input is enabled. If not changes to the input will be ignored. By default the alarm is enabled." ::= { aprisaXEExternalAlarm2 3 } aprisaXEExternalAlarm2Mapping OBJECT-TYPE SYNTAX AprisaXEAlarmMapping MAX-ACCESS read-write STATUS current DESCRIPTION "This defines how the second external alarm input is mapped to the remote alarms." ::= { aprisaXEExternalAlarm2 4 } aprisaXEExternalAlarm2Description OBJECT-TYPE SYNTAX DisplayString ( SIZE (0..64) ) MAX-ACCESS read-write STATUS current DESCRIPTION "A description (user defined) for the external alarm." ::= { aprisaXEExternalAlarm2 5 } aprisaXEExternalAlarm2Group OBJECT-GROUP OBJECTS { aprisaXEExternalAlarm2Status, aprisaXEExternalAlarm2Severity, aprisaXEExternalAlarm2Enabled, aprisaXEExternalAlarm2Mapping, aprisaXEExternalAlarm2Description } STATUS current DESCRIPTION "The AprisaXE second external alarm input group." ::= { aprisaXEGroups 16 } -- General configuration aprisaXEExternalAlarmPolarity OBJECT-TYPE SYNTAX AprisaXEAlarmPolarity MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the polarity used to indicate the presence of an alarm at an external alarm input." ::= { aprisaXEExternalAlarms 3 } aprisaXEExternalAlarmOutputPolarity OBJECT-TYPE SYNTAX INTEGER { polarityClosed (0), polarityOpen (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the polarity used to indicate the presence of an alarm at an external alarm output, this may be different from the input polarity." ::= { aprisaXEExternalAlarms 4 } aprisaXEExternalAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXEExternalAlarmPolarity, aprisaXEExternalAlarmOutputPolarity } STATUS current DESCRIPTION "The AprisaXE general external alarm details group." ::= { aprisaXEGroups 17 } -- The first external alarm output aprisaXEExternalAlarmOutputOne OBJECT IDENTIFIER ::= { aprisaXEExternalAlarms 5 } aprisaXEExternalAlarmOutputOneStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the first external alarm output." ::= { aprisaXEExternalAlarmOutputOne 1 } aprisaXEExternalAlarmOutputOneMapping OBJECT-TYPE SYNTAX AprisaXEAlarmMapping MAX-ACCESS read-write STATUS current DESCRIPTION "This defines how the first external alarm output is mapped to the alarms." ::= { aprisaXEExternalAlarmOutputOne 2 } aprisaXEExternalAlarmOutputOneGroup OBJECT-GROUP OBJECTS { aprisaXEExternalAlarmOutputOneStatus, aprisaXEExternalAlarmOutputOneMapping } STATUS current DESCRIPTION "The AprisaXE first external alarm output group." ::= { aprisaXEGroups 12 } -- The second external alarm output aprisaXEExternalAlarmOutputTwo OBJECT IDENTIFIER ::= { aprisaXEExternalAlarms 6 } aprisaXEExternalAlarmOutputTwoStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the second external alarm output." ::= { aprisaXEExternalAlarmOutputTwo 1 } aprisaXEExternalAlarmOutputTwoMapping OBJECT-TYPE SYNTAX AprisaXEAlarmMapping MAX-ACCESS read-write STATUS current DESCRIPTION "This defines how the second external alarm output is mapped to the alarms." ::= { aprisaXEExternalAlarmOutputTwo 2 } aprisaXEExternalAlarmOutputTwoGroup OBJECT-GROUP OBJECTS { aprisaXEExternalAlarmOutputTwoStatus, aprisaXEExternalAlarmOutputTwoMapping } STATUS current DESCRIPTION "The AprisaXE second external alarm output group." ::= { aprisaXEGroups 13 } -- The third external alarm output aprisaXEExternalAlarmOutputThree OBJECT IDENTIFIER ::= { aprisaXEExternalAlarms 7 } aprisaXEExternalAlarmOutputThreeStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the third external alarm output." ::= { aprisaXEExternalAlarmOutputThree 1 } aprisaXEExternalAlarmOutputThreeMapping OBJECT-TYPE SYNTAX AprisaXEAlarmMapping MAX-ACCESS read-write STATUS current DESCRIPTION "This defines how the third external alarm output is mapped to the alarms." ::= { aprisaXEExternalAlarmOutputThree 2 } aprisaXEExternalAlarmOutputThreeGroup OBJECT-GROUP OBJECTS { aprisaXEExternalAlarmOutputThreeStatus, aprisaXEExternalAlarmOutputThreeMapping } STATUS current DESCRIPTION "The AprisaXE third external alarm output group." ::= { aprisaXEGroups 14 } -- The fourth external alarm output aprisaXEExternalAlarmOutputFour OBJECT IDENTIFIER ::= { aprisaXEExternalAlarms 8 } aprisaXEExternalAlarmOutputFourStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the fourth external alarm output." ::= { aprisaXEExternalAlarmOutputFour 1 } aprisaXEExternalAlarmOutputFourMapping OBJECT-TYPE SYNTAX AprisaXEAlarmMapping MAX-ACCESS read-write STATUS current DESCRIPTION "This defines how the fourth external alarm output is mapped to the alarms." ::= { aprisaXEExternalAlarmOutputFour 2 } aprisaXEExternalAlarmOutputFourGroup OBJECT-GROUP OBJECTS { aprisaXEExternalAlarmOutputFourStatus, aprisaXEExternalAlarmOutputFourMapping } STATUS current DESCRIPTION "The AprisaXE fourth external alarm output group." ::= { aprisaXEGroups 15 } -- *************************************************************************** -- End External Alarms -- *************************************************************************** -- *************************************************************************** -- Remote Alarms -- -- This section specifies the MIB attributes for handling alarms from the -- remote terminal. The remote terminal can report a major or minor alarm -- or both. The MIB will provide access to the status of both the major and -- minor alarms. The remote alarms can be mapped to the external alarm outputs. -- *************************************************************************** aprisaXERemoteAlarms OBJECT IDENTIFIER ::= { aprisaXEObjects 16 } aprisaXEMajorRemoteAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the remote major alarm." ::= { aprisaXERemoteAlarms 1 } aprisaXEMajorRemoteAlarmOutput OBJECT-TYPE SYNTAX AprisaXEAlarmOutput MAX-ACCESS read-write STATUS obsolete DESCRIPTION "This defines how the remote major alarm is mapped to the external alarm outputs." ::= { aprisaXERemoteAlarms 2 } aprisaXEMinorRemoteAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the remote minor alarm." ::= { aprisaXERemoteAlarms 10 } aprisaXEMinorRemoteAlarmOutput OBJECT-TYPE SYNTAX AprisaXEAlarmOutput MAX-ACCESS read-write STATUS obsolete DESCRIPTION "This defines how the remote minor alarm is mapped to the external alarm outputs." ::= { aprisaXERemoteAlarms 11 } aprisaXERemoteAlarmGroup OBJECT-GROUP OBJECTS { aprisaXEMajorRemoteAlarmStatus, aprisaXEMajorRemoteAlarmOutput, aprisaXEMinorRemoteAlarmStatus, aprisaXEMinorRemoteAlarmOutput } STATUS obsolete DESCRIPTION "The AprisaXE remote alarm status group. This group has been replaced by the now mappable external alarm output OIDs aprisaXEExternalAlarmOutputXXXGroup." ::= { aprisaXEGroups 21 } -- *************************************************************************** -- MHSB Mode -- -- This section specifies the MIB attributes for handling MHSB Mode -- *************************************************************************** aprisaXEMHSB OBJECT IDENTIFIER ::= {aprisaXEObjects 19 } aprisaXEMHSBStatus OBJECT-TYPE SYNTAX FourRFMHSBStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The state of an MHSB configured terminal." ::= {aprisaXEMHSB 1} aprisaXEMHSBEnable OBJECT-TYPE SYNTAX INTEGER { disabled (0), enabled (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the terminal into Monitored Hot Standby Mode." ::= { aprisaXEMHSB 2} aprisaXEMHSBCommand OBJECT-TYPE SYNTAX FourRFMHSBCommand MAX-ACCESS read-write STATUS current DESCRIPTION "Commands to apply while in MHSB mode." ::= { aprisaXEMHSB 3} aprisaXEMHSBTerminalSelect OBJECT-TYPE SYNTAX INTEGER { none (0), terminalA (1), terminalB (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Configure terminal as terminal A or terminal B of an MHSB pair." ::= {aprisaXEMHSB 4} aprisaXEMHSBSwitchoverStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the alarm reflecting if a switchover has occurred." ::= {aprisaXEMHSB 5} aprisaXEMHSBGroup OBJECT-GROUP OBJECTS { aprisaXEMHSBStatus, aprisaXEMHSBEnable, aprisaXEMHSBCommand, aprisaXEMHSBTerminalSelect, aprisaXEMHSBSwitchoverStatus } STATUS current DESCRIPTION "The aprisaXE MHSB group." ::= { aprisaXEGroups 23} -- *************************************************************************** -- Fan Status -- -- This section specifies the MIB attributes for handling the fan status. -- *************************************************************************** aprisaXEFans OBJECT IDENTIFIER ::= { aprisaXEObjects 21 } aprisaXEFan1Status OBJECT-TYPE SYNTAX FourRFFanStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the fan one." ::= { aprisaXEFans 1 } aprisaXEFan2Status OBJECT-TYPE SYNTAX FourRFFanStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the fan two." ::= { aprisaXEFans 2 } aprisaXEFanEnable OBJECT-TYPE SYNTAX INTEGER { fansDisabled (0), fansEnabled (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Turn the fans on or off." ::= { aprisaXEFans 3 } aprisaXEFanGroup OBJECT-GROUP OBJECTS { aprisaXEFan1Status, aprisaXEFan2Status, aprisaXEFanEnable } STATUS current DESCRIPTION "The AprisaXE fan status group." ::= { aprisaXEGroups 26 } -- *************************************************************************** -- AlarmTable -- -- This section defines the alarm table. This is used to report all currently -- active alarms. A maximum of 500 alarms will be stored in the table. -- *************************************************************************** aprisaXEAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF AprisaXEAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table stores the currently active alarms. Up to 500 separate alarms will be stored in the table." ::= { aprisaXEObjects 26 } AprisaXEAlarmEntry ::= SEQUENCE { aprisaXEAlarmIndex INTEGER, aprisaXEAlarmSlot INTEGER, aprisaXEAlarmSource INTEGER, aprisaXEAlarmPort INTEGER, aprisaXEAlarmSeverity INTEGER, aprisaXEAlarmType INTEGER, aprisaXEAlarmTime OCTET STRING } aprisaXEAlarmEntry OBJECT-TYPE SYNTAX AprisaXEAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table entry index specification, just the alarm index." INDEX { aprisaXEAlarmIndex } ::= { aprisaXEAlarmTable 1 } aprisaXEAlarmIndex OBJECT-TYPE SYNTAX INTEGER ( 0..500 ) MAX-ACCESS read-only STATUS current DESCRIPTION "The index into the alarm table." ::= { aprisaXEAlarmEntry 1 } aprisaXEAlarmSlot OBJECT-TYPE SYNTAX AprisaXESlotNumber MAX-ACCESS read-only STATUS current DESCRIPTION "The number of the slot generating the alarm." ::= { aprisaXEAlarmEntry 2 } aprisaXEAlarmSource OBJECT-TYPE SYNTAX AprisaXEAlarmSource MAX-ACCESS read-only STATUS current DESCRIPTION "The source of the alarm, a card type or external." ::= { aprisaXEAlarmEntry 3 } aprisaXEAlarmPort OBJECT-TYPE SYNTAX AprisaXEPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "The source port of the alarm." ::= { aprisaXEAlarmEntry 4 } aprisaXEAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the alarm." ::= { aprisaXEAlarmEntry 5 } aprisaXEAlarmType OBJECT-TYPE SYNTAX AprisaXEAlarmType MAX-ACCESS read-only STATUS current DESCRIPTION "The type of the alarm." ::= { aprisaXEAlarmEntry 6 } aprisaXEAlarmTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The time that the alarm occurred." ::= { aprisaXEAlarmEntry 7 } -- *************************************************************************** -- End AlarmTable -- *************************************************************************** -- *************************************************************************** -- AlarmHistoryTable -- -- This section defines the alarm table. A maximum of 100 alarms will be stored -- in the table. -- *************************************************************************** aprisaXEAlarmHistoryTable OBJECT-TYPE SYNTAX SEQUENCE OF AprisaXEAlarmHistoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table stores a history of the alarms as they become active and cleared." ::= { aprisaXEObjects 31 } AprisaXEAlarmHistoryEntry ::= SEQUENCE { aprisaXEAlarmHistoryIndex INTEGER, aprisaXEAlarmHistorySlot INTEGER, aprisaXEAlarmHistorySource INTEGER, aprisaXEAlarmHistoryPort INTEGER, aprisaXEAlarmHistorySeverity INTEGER, aprisaXEAlarmHistoryType INTEGER, aprisaXEAlarmHistoryPresent INTEGER, aprisaXEAlarmHistoryTime OCTET STRING } aprisaXEAlarmHistoryEntry OBJECT-TYPE SYNTAX AprisaXEAlarmHistoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table entry index specification, just the alarm index." INDEX { aprisaXEAlarmHistoryIndex } ::= { aprisaXEAlarmHistoryTable 1 } aprisaXEAlarmHistoryIndex OBJECT-TYPE SYNTAX INTEGER ( 0..100 ) MAX-ACCESS read-only STATUS current DESCRIPTION "The index into the alarm history table." ::= { aprisaXEAlarmHistoryEntry 1 } aprisaXEAlarmHistorySlot OBJECT-TYPE SYNTAX AprisaXESlotNumber MAX-ACCESS read-only STATUS current DESCRIPTION "The number of the slot generating the alarm." ::= { aprisaXEAlarmHistoryEntry 2 } aprisaXEAlarmHistorySource OBJECT-TYPE SYNTAX AprisaXEAlarmSource MAX-ACCESS read-only STATUS current DESCRIPTION "The source of the alarm, a card type or external." ::= { aprisaXEAlarmHistoryEntry 3 } aprisaXEAlarmHistoryPort OBJECT-TYPE SYNTAX AprisaXEPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "The source port of the alarm." ::= { aprisaXEAlarmHistoryEntry 4 } aprisaXEAlarmHistorySeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the alarm." ::= { aprisaXEAlarmHistoryEntry 5 } aprisaXEAlarmHistoryType OBJECT-TYPE SYNTAX AprisaXEAlarmType MAX-ACCESS read-only STATUS current DESCRIPTION "The type of the alarm." ::= { aprisaXEAlarmHistoryEntry 6 } aprisaXEAlarmHistoryPresent OBJECT-TYPE SYNTAX FourRFAlarmPresent MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the alarm is present or not." ::= { aprisaXEAlarmHistoryEntry 7 } aprisaXEAlarmHistoryTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The time that the alarm state change occurred." ::= { aprisaXEAlarmHistoryEntry 8 } -- *************************************************************************** -- End AlarmHistoryTable -- *************************************************************************** aprisaXEAlarmControl OBJECT IDENTIFIER ::= { aprisaXEObjects 32 } aprisaXEAlarmHistoryCommand OBJECT-TYPE SYNTAX INTEGER { noCommand (0), clearHistory (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Allows the alarm history table to be cleared." ::= { aprisaXEAlarmControl 1 } aprisaXEAlarmControlGroup OBJECT-GROUP OBJECTS { aprisaXEAlarmHistoryCommand } STATUS current DESCRIPTION "The AprisaXE alarm control group." ::= { aprisaXEGroups 32 } -- *************************************************************************** -- Transmitter - there is only one transmitter for each AprisaXE -- -- NB: The units for all fields need to be confirmed -- -- *************************************************************************** aprisaXETransmitter OBJECT IDENTIFIER ::= { aprisaXEObjects 36 } aprisaXETransmitterStatus OBJECT-TYPE SYNTAX INTEGER { transmitterOff (0), transmitterOn (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the transmitter is currently on or off." ::= { aprisaXETransmitter 1 } aprisaXETransmitterCommand OBJECT-TYPE SYNTAX INTEGER { noCommand (0), transmitterOff (1), transmitterOn (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Commands used to control the transmitter, currently the transmitter can be switched on and off. No other commands are defined." ::= { aprisaXETransmitter 2 } aprisaXETransmitterSynthesiserStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter synthesiser." ::= { aprisaXETransmitter 3 } aprisaXETransmitter5VPowerStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter 5V power supply." ::= { aprisaXETransmitter 4 } aprisaXETransmitter11VPowerStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter 11V power supply." ::= { aprisaXETransmitter 5 } aprisaXETransmitter28VPowerStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter 28V power supply." ::= { aprisaXETransmitter 6 } aprisaXETransmitterFrequency OBJECT-TYPE SYNTAX FourRFFrequency MAX-ACCESS read-write STATUS current DESCRIPTION "The terminal transmit frequency in MHz. The possible bands are: 330 to 400 MHz (300 MHz) 400 to 470 MHz (400 MHz) 1350 to 1550 MHz (1400 MHz) The frequency value should be supplied in Hz." ::= { aprisaXETransmitter 7 } aprisaXETransmitterPower OBJECT-TYPE SYNTAX FourRFTxPower MAX-ACCESS read-write STATUS current DESCRIPTION "The TX power value, the value should be entered in dB." ::= { aprisaXETransmitter 8 } aprisaXETransmitterAGC OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The Automatic Gain Control value in millivolts." ::= { aprisaXETransmitter 9 } aprisaXETransmitterForwardPower OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The forward power measurement value in millivolts." ::= { aprisaXETransmitter 10 } aprisaXETransmitterReversePower OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The reverse power value in millivolts." ::= { aprisaXETransmitter 11 } aprisaXETransmitterTemperature OBJECT-TYPE SYNTAX FourRFTemperature MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The temperature value in degrees Celcius." ::= { aprisaXETransmitter 12 } aprisaXETransmitterVTune OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The voltage output from TX synth." ::= { aprisaXETransmitter 13 } aprisaXETransmitter28VSupply OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The 28V supply rail value in millivolts." ::= { aprisaXETransmitter 14 } aprisaXETransmitter11VSupply OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The 11V supply rail value in millivolts." ::= { aprisaXETransmitter 15 } aprisaXETransmitter5VDigitalSupply OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The 5V digital supply rail value in millivolts." ::= { aprisaXETransmitter 16 } aprisaXETransmitter7VSupply OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The 7V RF supply rail value in millivolts." ::= { aprisaXETransmitter 17 } aprisaXETransmitter9VSupply OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The 9V supply synthesiser rail value in millivolts." ::= { aprisaXETransmitter 18 } aprisaXETransmitterCharacterisationDataStatus OBJECT-TYPE SYNTAX AprisaXEDataStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter characterisation data." ::= { aprisaXETransmitter 19 } aprisaXETransmitterSerialNumber OBJECT-TYPE SYNTAX FourRFSerialNumber MAX-ACCESS read-only STATUS current DESCRIPTION "The unique module serial number for the transmitter." ::= { aprisaXETransmitter 20 } aprisaXETransmitterReturnLoss OBJECT-TYPE SYNTAX AprisaXEDbValue MAX-ACCESS read-only STATUS current DESCRIPTION "The return loss for the transmitter." ::= { aprisaXETransmitter 21 } aprisaXETransmitterMibDataStatus OBJECT-TYPE SYNTAX AprisaXEDataStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter MIB data." ::= { aprisaXETransmitter 22 } aprisaXETransmitterADCChZero OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS current DESCRIPTION "The TX adc ch zero voltage." ::= { aprisaXETransmitter 23 } aprisaXETransmitterADCChOne OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS current DESCRIPTION "The TX adc ch one voltage." ::= { aprisaXETransmitter 24 } aprisaXETransmitterADCChTwo OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS current DESCRIPTION "The TX adc ch two voltage." ::= { aprisaXETransmitter 25 } aprisaXETransmitterADCChThree OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS current DESCRIPTION "The TX adc ch three voltage." ::= { aprisaXETransmitter 26 } aprisaXETransmitterADCChFour OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS current DESCRIPTION "The TX adc ch four voltage." ::= { aprisaXETransmitter 27 } aprisaXETransmitterADCChFive OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS current DESCRIPTION "The TX adc ch five voltage." ::= { aprisaXETransmitter 28 } aprisaXETransmitterADCChSix OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS current DESCRIPTION "The TX adc ch six voltage." ::= { aprisaXETransmitter 29 } aprisaXETransmitterADCChSeven OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS current DESCRIPTION "The TX adc ch seven voltage." ::= { aprisaXETransmitter 30 } aprisaXETransmitterADCChEight OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS current DESCRIPTION "The TX adc ch eight voltage." ::= { aprisaXETransmitter 31 } aprisaXETransmitterADCChNine OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS current DESCRIPTION "The TX adc ch nine voltage." ::= { aprisaXETransmitter 32 } aprisaXETransmitterADCChTen OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS current DESCRIPTION "The TX adc ch ten voltage." ::= { aprisaXETransmitter 33 } aprisaXETransmitterADCChEleven OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS current DESCRIPTION "The TX adc ch eleven voltage." ::= { aprisaXETransmitter 34 } aprisaXETransmitterNeg5VPowerStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter Negative 5V power supply." ::= { aprisaXETransmitter 35 } aprisaXETransmitterAmplifierBalanceStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter Balanced Power Amplifier." ::= { aprisaXETransmitter 36 } aprisaXETransmitterTcxoAdjustment OBJECT-TYPE SYNTAX INTEGER { txTCXOAdjustmentPosFive (0), txTCXOAdjustmentPosOne (1), txTCXOAdjustmentZero (2), txTCXOAdjustmentNegOne (3), txTCXOAdjustmentNegFive (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The TX TCXO adjustment to be made by the customer, to tune the TCXO. This is a shift in DAC steps." ::= { aprisaXETransmitter 37 } aprisaXETransmitterSynthFileVersion OBJECT-TYPE SYNTAX INTEGER ( 0..999 ) MAX-ACCESS read-only STATUS current DESCRIPTION "The version of the Synth File loaded from the filesystem." ::= { aprisaXETransmitter 38 } aprisaXETransmitterOperationalDataVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The version of the operational data for the transmitter." ::= { aprisaXETransmitter 39 } aprisaXETransmitterSwCompatibility OBJECT-TYPE SYNTAX INTEGER ( 0..999 ) MAX-ACCESS read-only STATUS current DESCRIPTION "The transmitter software compatibility number." ::= { aprisaXETransmitter 40 } aprisaXETransmitterGroup OBJECT-GROUP OBJECTS { aprisaXETransmitterStatus, aprisaXETransmitterCommand, aprisaXETransmitterSynthesiserStatus, aprisaXETransmitter5VPowerStatus, aprisaXETransmitter11VPowerStatus, aprisaXETransmitter28VPowerStatus, aprisaXETransmitterFrequency, aprisaXETransmitterPower, aprisaXETransmitterAGC, aprisaXETransmitterForwardPower, aprisaXETransmitterReversePower, aprisaXETransmitterTemperature, aprisaXETransmitterVTune, aprisaXETransmitter28VSupply, aprisaXETransmitter11VSupply, aprisaXETransmitter5VDigitalSupply, aprisaXETransmitter7VSupply, aprisaXETransmitter9VSupply, aprisaXETransmitterCharacterisationDataStatus, aprisaXETransmitterSerialNumber, aprisaXETransmitterReturnLoss, aprisaXETransmitterMibDataStatus, aprisaXETransmitterADCChZero, aprisaXETransmitterADCChOne, aprisaXETransmitterADCChTwo, aprisaXETransmitterADCChThree, aprisaXETransmitterADCChFour, aprisaXETransmitterADCChFive, aprisaXETransmitterADCChSix, aprisaXETransmitterADCChSeven, aprisaXETransmitterADCChEight, aprisaXETransmitterADCChNine, aprisaXETransmitterADCChTen, aprisaXETransmitterADCChEleven, aprisaXETransmitterNeg5VPowerStatus, aprisaXETransmitterAmplifierBalanceStatus, aprisaXETransmitterTcxoAdjustment, aprisaXETransmitterSynthFileVersion } STATUS current DESCRIPTION "The AprisaXE transmitter settings group." ::= { aprisaXEGroups 36 } -- *************************************************************************** -- End Transmitter -- *************************************************************************** -- *************************************************************************** -- Receiver - there is only one Receiver for each AprisaXE -- -- NB: The units for all fields need to be confirmed -- -- *************************************************************************** aprisaXEReceiver OBJECT IDENTIFIER ::= { aprisaXEObjects 51 } aprisaXEReceiverStatus OBJECT-TYPE SYNTAX INTEGER { receiverOff (0), receiverOn (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the receiver, currently the receiver can be On/Off and the loopback can be On/Off." ::= { aprisaXEReceiver 1 } aprisaXEReceiverCommand OBJECT-TYPE SYNTAX INTEGER { noCommand (0), receiverOff (1), receiverOn (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Commands used to control the receiver, currently the receiver can be switched on and off and the loopback option switched on and off." ::= { aprisaXEReceiver 2 } aprisaXEReceiverSynthesiserStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the receiver synthesiser." ::= { aprisaXEReceiver 3 } aprisaXEReceiver12VPowerStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the Receiver 12V power supply." ::= { aprisaXEReceiver 4 } aprisaXEReceiverFrequency OBJECT-TYPE SYNTAX FourRFFrequency MAX-ACCESS read-write STATUS current DESCRIPTION "The terminal transmit frequency in MHz. The possible bands are: 330 to 400 MHz (300 MHz) 400 to 470 MHz (400 MHz) 1350 to 1550 MHz (1400 MHz) The frequency value should be supplied in Hz." ::= { aprisaXEReceiver 5 } aprisaXEReceiverRSSI OBJECT-TYPE SYNTAX FourRFRSSI MAX-ACCESS read-only STATUS current DESCRIPTION "The characterised RSSI Voltage." ::= { aprisaXEReceiver 6 } aprisaXEReceiverTemperature OBJECT-TYPE SYNTAX FourRFTemperature MAX-ACCESS read-only STATUS current DESCRIPTION "The temperature value, this should only be accessible in engineering mode." ::= { aprisaXEReceiver 8 } aprisaXEReceiverVTune OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The voltage output from RX synth value, this should only be accessible in engineering mode." ::= { aprisaXEReceiver 9 } aprisaXEReceiver9VSupply OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The 9V supply rail value, this should only be accessible in engineering mode." ::= { aprisaXEReceiver 10 } aprisaXEReceiver5VSupply OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The 5V supply rail value, this should only be accessible in engineering mode." ::= { aprisaXEReceiver 11 } aprisaXEReceiverModemAGC OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The modem AGC, this should only be accessible in engineering mode." ::= { aprisaXEReceiver 12 } aprisaXEReceiverNeg1V5Supply OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The -1.5V supply rail value, this should only be accessible in engineering mode." ::= { aprisaXEReceiver 13 } aprisaXEReceiver3V3Supply OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The 3.3V supply rail value, this should only be accessible in engineering mode." ::= { aprisaXEReceiver 14 } aprisaXEReceiverDacTest OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The DacTest value, this should only be accessible in engineering mode." ::= { aprisaXEReceiver 15 } aprisaXEReceiverCharacterisationDataStatus OBJECT-TYPE SYNTAX AprisaXEDataStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the receiver characterisation data." ::= { aprisaXEReceiver 16 } aprisaXEReceiverSerialNumber OBJECT-TYPE SYNTAX FourRFSerialNumber MAX-ACCESS read-only STATUS current DESCRIPTION "The unique module serial number for the receiver." ::= { aprisaXEReceiver 17 } aprisaXEReceiverRfLoopback OBJECT-TYPE SYNTAX FourRFLoopback MAX-ACCESS read-write STATUS current DESCRIPTION "Enables and disabled RF loopback." ::= { aprisaXEReceiver 18 } aprisaXEReceiverRfLoopbackTimeout OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "The number of seconds after which RF loopback should timeout." ::= { aprisaXEReceiver 19 } aprisaXEReceiverMibDataStatus OBJECT-TYPE SYNTAX AprisaXEDataStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the receiver MIB data." ::= { aprisaXEReceiver 20 } aprisaXEReceiverADCChZero OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS current DESCRIPTION "The RX adc ch zero voltage." ::= { aprisaXEReceiver 21 } aprisaXEReceiverADCChOne OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS current DESCRIPTION "The RX adc ch one voltage." ::= { aprisaXEReceiver 22 } aprisaXEReceiverADCChTwo OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS current DESCRIPTION "The RX adc ch two voltage." ::= { aprisaXEReceiver 23 } aprisaXEReceiverADCChThree OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS current DESCRIPTION "The RX adc ch three voltage." ::= { aprisaXEReceiver 24 } aprisaXEReceiverADCChFour OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS current DESCRIPTION "The RX adc ch four voltage." ::= { aprisaXEReceiver 25 } aprisaXEReceiverADCChFive OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS current DESCRIPTION "The RX adc ch five voltage." ::= { aprisaXEReceiver 26 } aprisaXEReceiverADCChSix OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS current DESCRIPTION "The RX adc ch six voltage." ::= { aprisaXEReceiver 27 } aprisaXEReceiverADCChSeven OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS current DESCRIPTION "The RX adc ch seven voltage." ::= { aprisaXEReceiver 28 } aprisaXEReceiverADCChEight OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS current DESCRIPTION "The RX adc ch eight voltage." ::= { aprisaXEReceiver 29 } aprisaXEReceiverADCChNine OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS current DESCRIPTION "The RX adc ch nine voltage." ::= { aprisaXEReceiver 30 } aprisaXEReceiverADCChTen OBJECT-TYPE SYNTAX AprisaXEAdcVoltage MAX-ACCESS read-only STATUS current DESCRIPTION "The RX adc ch ten voltage." ::= { aprisaXEReceiver 31 } aprisaXEReceiverRSSIThresQPSKLowerOn OBJECT-TYPE SYNTAX Integer32(-110..-40) MAX-ACCESS read-write STATUS current DESCRIPTION "The QPSK Lower ON RSSI Threshold." ::= { aprisaXEReceiver 32 } aprisaXEReceiverRSSIThres16QAMLowerOn OBJECT-TYPE SYNTAX Integer32(-110..-40) MAX-ACCESS read-write STATUS current DESCRIPTION "The 16QAM Lower ON RSSI Threshold." ::= { aprisaXEReceiver 33 } aprisaXEReceiverRSSIThres32QAMLowerOn OBJECT-TYPE SYNTAX Integer32(-110..-40) MAX-ACCESS read-write STATUS current DESCRIPTION "The 32QAM Lower ON RSSI Threshold." ::= { aprisaXEReceiver 34 } aprisaXEReceiverRSSIThres64QAMLowerOn OBJECT-TYPE SYNTAX Integer32(-110..-40) MAX-ACCESS read-write STATUS current DESCRIPTION "The 64QAM Lower ON RSSI Threshold." ::= { aprisaXEReceiver 35 } aprisaXEReceiverSynthFileVersion OBJECT-TYPE SYNTAX INTEGER ( 0..999 ) MAX-ACCESS read-only STATUS current DESCRIPTION "The version of the Synth File loaded from the filesystem." ::= { aprisaXEReceiver 36 } aprisaXEReceiverOperationalDataVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The version of the operational data of the receiver." ::= { aprisaXEReceiver 37 } aprisaXEReceiverSwCompatibility OBJECT-TYPE SYNTAX INTEGER ( 0..999 ) MAX-ACCESS read-only STATUS current DESCRIPTION "The receiver software compatibility number." ::= { aprisaXEReceiver 38 } aprisaXETReceiverGroup OBJECT-GROUP OBJECTS { aprisaXEReceiverStatus, aprisaXEReceiverCommand, aprisaXEReceiverSynthesiserStatus, aprisaXEReceiver12VPowerStatus, aprisaXEReceiverFrequency, aprisaXEReceiverRSSI, aprisaXEReceiverTemperature, aprisaXEReceiverVTune, aprisaXEReceiver9VSupply, aprisaXEReceiver5VSupply, aprisaXEReceiverModemAGC, aprisaXEReceiverNeg1V5Supply, aprisaXEReceiver3V3Supply, aprisaXEReceiverDacTest, aprisaXEReceiverCharacterisationDataStatus, aprisaXEReceiverSerialNumber, aprisaXEReceiverRfLoopback, aprisaXEReceiverRfLoopbackTimeout, aprisaXEReceiverMibDataStatus, aprisaXEReceiverADCChZero, aprisaXEReceiverADCChOne, aprisaXEReceiverADCChTwo, aprisaXEReceiverADCChThree, aprisaXEReceiverADCChFour, aprisaXEReceiverADCChFive, aprisaXEReceiverADCChSix, aprisaXEReceiverADCChSeven, aprisaXEReceiverADCChEight, aprisaXEReceiverADCChNine, aprisaXEReceiverADCChTen, aprisaXEReceiverRSSIThresQPSKLowerOn, aprisaXEReceiverRSSIThres16QAMLowerOn, aprisaXEReceiverRSSIThres32QAMLowerOn, aprisaXEReceiverRSSIThres64QAMLowerOn, aprisaXEReceiverSynthFileVersion } STATUS current DESCRIPTION "The AprisaXE Receiver settings group." ::= { aprisaXEGroups 46 } -- *************************************************************************** -- End Receiver -- *************************************************************************** -- *************************************************************************** -- Modem - there is only one Modem for each AprisaXE -- -- NB: The units for all fields need to be confirmed -- -- *************************************************************************** aprisaXEModem OBJECT IDENTIFIER ::= { aprisaXEObjects 61 } aprisaXEModemDemodAligmentStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the demodulator alignment." ::= { aprisaXEModem 1 } aprisaXEModemTdmAligmentStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the TDM alignment." ::= { aprisaXEModem 2 } aprisaXEModemRefAStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the REFa clock." ::= { aprisaXEModem 3 } aprisaXEModemRefBStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the REFb clock." ::= { aprisaXEModem 4 } aprisaXEModemUncorrectableBlockCount OBJECT-TYPE SYNTAX FourRFErrorCounter MAX-ACCESS read-only STATUS current DESCRIPTION "Count of uncorrectable blocks since last read." ::= { aprisaXEModem 5 } aprisaXEModemIQData OBJECT-TYPE SYNTAX AprisaXEIQData MAX-ACCESS read-only STATUS current DESCRIPTION "A list of I/Q data pairs, this is a sequence of byes values the first byte is an I value, the second a Q value." ::= { aprisaXEModem 6 } aprisaXEModemSyncStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the link lock." ::= { aprisaXEModem 7 } aprisaXEModemFreqOffsetEnable OBJECT-TYPE SYNTAX INTEGER { offsetDisabled (0), offsetEnabled (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Turn the Modulator frequency offset of 50kHz on or off." ::= { aprisaXEModem 8 } aprisaXEModemInterleaverEnable OBJECT-TYPE SYNTAX INTEGER { interleaverEnabled (100), interleaverDisabled (101), interleaverDefault (102) } MAX-ACCESS read-write STATUS current DESCRIPTION "Interleaver being used on the modem. Trade off between link latency and FEC performance." ::= { aprisaXEModem 9 } aprisaXEModemQPSKCoding OBJECT-TYPE SYNTAX INTEGER { grayCoded (0), nonGrayCoded (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Encoding and Decoding being used for QPSK. Can be either Gray coded or non Gray coded." ::= { aprisaXEModem 10 } aprisaXEModemConfigVersion OBJECT-TYPE SYNTAX INTEGER ( 0..999 ) MAX-ACCESS read-only STATUS current DESCRIPTION "Modem Configuration file version." ::= { aprisaXEModem 11 } aprisaXEModemGroup OBJECT-GROUP OBJECTS { aprisaXEModemDemodAligmentStatus, aprisaXEModemTdmAligmentStatus, aprisaXEModemRefAStatus, aprisaXEModemRefBStatus, aprisaXEModemUncorrectableBlockCount, aprisaXEModemIQData, aprisaXEModemSyncStatus, aprisaXEModemFreqOffsetEnable, aprisaXEModemInterleaverEnable, aprisaXEModemQPSKCoding, aprisaXEModemConfigVersion } STATUS current DESCRIPTION "The AprisaXE Modem settings group." ::= { aprisaXEGroups 53 } -- *************************************************************************** -- End Modem -- *************************************************************************** -- *************************************************************************** -- BoardTable - Table for storing basic per slot details. -- *************************************************************************** aprisaXEBoardTable OBJECT-TYPE SYNTAX SEQUENCE OF AprisaXEBoardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table stores the basic information for the plugin slots." ::= { aprisaXEObjects 66 } aprisaXEBoardEntry OBJECT-TYPE SYNTAX AprisaXEBoardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Slot Information." INDEX { aprisaXEBoardSlot } ::= { aprisaXEBoardTable 1 } -- Each table entry consists of the type of the card in the slot, -- the hardware and firmware version numbers and the hardware software -- compatibility number. AprisaXEBoardEntry ::= SEQUENCE { aprisaXEBoardSlot INTEGER, aprisaXEBoardType INTEGER, aprisaXEExpectedBoardType INTEGER, aprisaXEBoardHardwareVersion INTEGER, aprisaXEBoardFirmwareVersion INTEGER, aprisaXEBoardHSCNumber INTEGER, aprisaXEBoardSerialNumber OCTET STRING } aprisaXEBoardSlot OBJECT-TYPE SYNTAX AprisaXESlotNumber MAX-ACCESS read-only STATUS current DESCRIPTION "The slot number in which the board resides, the physical slots are numbered from zero to ten and mapped to one to eleven in the MIB. The motherboard is therefore in physical slot 0 but MIB slot 1." ::= { aprisaXEBoardEntry 1 } aprisaXEBoardType OBJECT-TYPE SYNTAX AprisaXECardType MAX-ACCESS read-only STATUS current DESCRIPTION "The type of the board in the slot. The types are as follows: - none : there is no card in the slot - modem : this card will be fitted in physical slot 0 - transmitter : the transmitter card, this will be in physical slot 9 - receiver : the receiver card, this will be in physical slot 10 - quadJET : e1/t1 4 port card" ::= { aprisaXEBoardEntry 2 } aprisaXEExpectedBoardType OBJECT-TYPE SYNTAX AprisaXECardType MAX-ACCESS read-write STATUS current DESCRIPTION "The type of the board expected in the slot. The types are as follows: - none : there is no card in the slot - modem : this card will be fitted in physical slot 0 - transmitter : the transmitter card, this will be in physical slot 9 - receiver : the receiver card, this will be in physical slot 10 - quadJET : e1/t1 4 port card" ::= { aprisaXEBoardEntry 3 } aprisaXEBoardHardwareVersion OBJECT-TYPE SYNTAX AprisaXEHardwareVersion MAX-ACCESS read-only STATUS current DESCRIPTION "Field indicating the hardware version for the board in the slot." ::= { aprisaXEBoardEntry 4 } aprisaXEBoardFirmwareVersion OBJECT-TYPE SYNTAX AprisaXEHardwareVersion MAX-ACCESS read-only STATUS current DESCRIPTION "Field indicating the firmware version for the board in the slot." ::= { aprisaXEBoardEntry 5 } aprisaXEBoardHSCNumber OBJECT-TYPE SYNTAX AprisaXEHardwareVersion MAX-ACCESS read-only STATUS current DESCRIPTION "Field indicating the hardware software configuration number for the board in the slot." ::= { aprisaXEBoardEntry 6 } aprisaXEBoardSerialNumber OBJECT-TYPE SYNTAX FourRFSerialNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Field indicating the module serial number for the card in the slot." ::= { aprisaXEBoardEntry 7 } -- *************************************************************************** -- End BoardTable -- *************************************************************************** -- *************************************************************************** -- Alarms - notifications should be defined for each alarm. -- -- Each alarm has at least three components: -- Its current status noAlarm or alarmPresent indicating whether the alarm -- is present or not. -- -- The alarm severity indicating whether the alarm is major or minor (or -- anything else we want) -- -- A flag indicating whether the alarm is enabled -- (all alarms are enabled by default) -- -- Currently all objects are read-only and would be configured from the -- MIB configuration at startup it is possible to allow the user to change -- the severity and to enable and disable alarms if this is considered useful. -- -- *************************************************************************** aprisaXELinkAlarms OBJECT IDENTIFIER ::= { aprisaXEObjects 86 } -- *************************************************************************** -- The Transmitter Alarms -- *************************************************************************** aprisaXETransmitterAlarms OBJECT IDENTIFIER ::= { aprisaXELinkAlarms 1 } -- -- Forward Power High Alarm -- -- This is a minor alarm -- aprisaXEForwardPowerHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 1 } aprisaXEForwardPowerHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the forward power too high alarm." ::= { aprisaXEForwardPowerHiAlarm 1 } aprisaXEForwardPowerHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the forward power too high alarm." ::= { aprisaXEForwardPowerHiAlarm 2 } aprisaXEForwardPowerHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the forward power too high alarm is enabled." ::= { aprisaXEForwardPowerHiAlarm 3 } aprisaXEForwardPowerHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the forward power too high alarm will be set." ::= { aprisaXEForwardPowerHiAlarm 4 } aprisaXEForwardPowerHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the forward power alarm will be cleared." ::= { aprisaXEForwardPowerHiAlarm 5 } aprisaXEForwardPowerHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXEForwardPowerHiAlarmStatus, aprisaXEForwardPowerHiAlarmSeverity, aprisaXEForwardPowerHiAlarmEnabled, aprisaXEForwardPowerHiAlarmThreshold, aprisaXEForwardPowerHiAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE forward power too high alarm group." ::= { aprisaXEGroups 56 } -- -- Forward Power Low Alarm -- -- This is a minor alarm -- aprisaXEForwardPowerLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 2 } aprisaXEForwardPowerLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the forward power too low alarm." ::= { aprisaXEForwardPowerLoAlarm 1 } aprisaXEForwardPowerLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the forward power too low alarm." ::= { aprisaXEForwardPowerLoAlarm 2 } aprisaXEForwardPowerLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the forward power too low alarm is enabled." ::= { aprisaXEForwardPowerLoAlarm 3 } aprisaXEForwardPowerLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the forward power too low alarm will be set." ::= { aprisaXEForwardPowerLoAlarm 4 } aprisaXEForwardPowerLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the forward power too low alarm will be cleared." ::= { aprisaXEForwardPowerLoAlarm 5 } aprisaXEForwardPowerLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXEForwardPowerLoAlarmStatus, aprisaXEForwardPowerLoAlarmSeverity, aprisaXEForwardPowerLoAlarmEnabled, aprisaXEForwardPowerLoAlarmThreshold, aprisaXEForwardPowerLoAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE forward power low alarm group." ::= { aprisaXEGroups 61 } -- -- Reverse Power Too High Alarm -- aprisaXEReversePowerHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 3 } aprisaXEReversePowerHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the reverse power out of limits alarm." ::= { aprisaXEReversePowerHiAlarm 1 } aprisaXEReversePowerHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the reverse power out of limits alarm." ::= { aprisaXEReversePowerHiAlarm 2 } aprisaXEReversePowerHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the reverse power out of limits alarm is enabled." ::= { aprisaXEReversePowerHiAlarm 3 } aprisaXEReversePowerHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the reverse power alarm will be set." ::= { aprisaXEReversePowerHiAlarm 4 } aprisaXEReversePowerHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the reverse power alarm will be cleared." ::= { aprisaXEReversePowerHiAlarm 5 } aprisaXEReversePowerHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXEReversePowerHiAlarmStatus, aprisaXEReversePowerHiAlarmSeverity, aprisaXEReversePowerHiAlarmEnabled, aprisaXEReversePowerHiAlarmThreshold, aprisaXEReversePowerHiAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE reverse power too high alarm group." ::= { aprisaXEGroups 66 } -- -- Reverse Power Too Low Alarm -- aprisaXEReversePowerLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 4 } aprisaXEReversePowerLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the reverse power out of limits alarm." ::= { aprisaXEReversePowerLoAlarm 1 } aprisaXEReversePowerLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the reverse power out of limits alarm." ::= { aprisaXEReversePowerLoAlarm 2 } aprisaXEReversePowerLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the reverse power out of limits alarm is enabled." ::= { aprisaXEReversePowerLoAlarm 3 } aprisaXEReversePowerLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the reverse power alarm will be set." ::= { aprisaXEReversePowerLoAlarm 4 } aprisaXEReversePowerLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the reverse power alarm will be cleared." ::= { aprisaXEReversePowerLoAlarm 5 } aprisaXEReversePowerLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXEReversePowerLoAlarmStatus, aprisaXEReversePowerLoAlarmSeverity, aprisaXEReversePowerLoAlarmEnabled, aprisaXEReversePowerLoAlarmThreshold, aprisaXEReversePowerLoAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE reverse power too low alarm group." ::= { aprisaXEGroups 71 } -- -- Transmitter PA Temperature Alarm -- -- This alarm is raised when the transmitter temperature exceeds a defined -- threshold. This is a major alarm as the transmitter will be switched off -- when this alarm is present. -- aprisaXETxPaTempAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 5 } aprisaXETxPaTempAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the transmitter temperature too high alarm." ::= { aprisaXETxPaTempAlarm 1 } aprisaXETxPaTempAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the transmitter temperature too high alarm." ::= { aprisaXETxPaTempAlarm 2 } aprisaXETxPaTempAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the transmitter temperature too high alarm is enabled." ::= { aprisaXETxPaTempAlarm 3 } aprisaXETxPaTempAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter temperature too high alarm will be set." ::= { aprisaXETxPaTempAlarm 4 } aprisaXETxPaTempAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter temperature too high will be cleared." ::= { aprisaXETxPaTempAlarm 5 } aprisaXETxPaTempAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxPaTempAlarmStatus, aprisaXETxPaTempAlarmSeverity, aprisaXETxPaTempAlarmEnabled, aprisaXETxPaTempAlarmThreshold, aprisaXETxPaTempAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE transmitter temperature too high alarm group." ::= { aprisaXEGroups 76 } aprisaXETxPaTempWarnAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 6 } aprisaXETxPaTempWarnAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the transmitter temperature warning alarm." ::= { aprisaXETxPaTempWarnAlarm 1 } aprisaXETxPaTempWarnAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the transmitter temperature warning alarm." ::= { aprisaXETxPaTempWarnAlarm 2 } aprisaXETxPaTempWarnAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the transmitter temperature warning alarm is enabled." ::= { aprisaXETxPaTempWarnAlarm 3 } aprisaXETxPaTempWarnAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter temperature warning alarm will be set." ::= { aprisaXETxPaTempWarnAlarm 4 } aprisaXETxPaTempWarnAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter temperature warning will be cleared." ::= { aprisaXETxPaTempWarnAlarm 5 } aprisaXETxPaTempWarnAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxPaTempWarnAlarmStatus, aprisaXETxPaTempWarnAlarmSeverity, aprisaXETxPaTempWarnAlarmEnabled, aprisaXETxPaTempWarnAlarmThreshold, aprisaXETxPaTempWarnAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE transmitter temperature warning alarm group." ::= { aprisaXEGroups 81 } aprisaXETxAgcHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 7 } aprisaXETxAgcHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the transmitter AGC too high alarm." ::= { aprisaXETxAgcHiAlarm 1 } aprisaXETxAgcHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the transmitter AGC too high alarm." ::= { aprisaXETxAgcHiAlarm 2 } aprisaXETxAgcHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the transmitter AGC too high alarm is enabled." ::= { aprisaXETxAgcHiAlarm 3 } aprisaXETxAgcHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter AGC too high alarm will be set." ::= { aprisaXETxAgcHiAlarm 4 } aprisaXETxAgcHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter AGC too high will be cleared." ::= { aprisaXETxAgcHiAlarm 5 } aprisaXETxAgcHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxAgcHiAlarmStatus, aprisaXETxAgcHiAlarmSeverity, aprisaXETxAgcHiAlarmEnabled, aprisaXETxAgcHiAlarmThreshold, aprisaXETxAgcHiAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE transmitter AGC too high alarm group." ::= { aprisaXEGroups 86 } aprisaXETxAgcLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 8 } aprisaXETxAgcLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the transmitter AGC too low alarm." ::= { aprisaXETxAgcLoAlarm 1 } aprisaXETxAgcLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the transmitter AGC too low alarm." ::= { aprisaXETxAgcLoAlarm 2 } aprisaXETxAgcLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the transmitter AGC too low alarm is enabled." ::= { aprisaXETxAgcLoAlarm 3 } aprisaXETxAgcLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter AGC too low alarm will be set." ::= { aprisaXETxAgcLoAlarm 4 } aprisaXETxAgcLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter AGC too low will be cleared." ::= { aprisaXETxAgcLoAlarm 5 } aprisaXETxAgcLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxAgcLoAlarmStatus, aprisaXETxAgcLoAlarmSeverity, aprisaXETxAgcLoAlarmEnabled, aprisaXETxAgcLoAlarmThreshold, aprisaXETxAgcLoAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE transmitter AGC too low alarm group." ::= { aprisaXEGroups 91 } aprisaXETxVtuneHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 9 } aprisaXETxVtuneHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the transmitter VTUNE too high alarm." ::= { aprisaXETxVtuneHiAlarm 1 } aprisaXETxVtuneHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the transmitter VTUNE too high alarm." ::= { aprisaXETxVtuneHiAlarm 2 } aprisaXETxVtuneHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the transmitter VTUNE too high alarm is enabled." ::= { aprisaXETxVtuneHiAlarm 3 } aprisaXETxVtuneHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter VTUNE too high alarm will be set." ::= { aprisaXETxVtuneHiAlarm 4 } aprisaXETxVtuneHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter VTUNE too high will be cleared." ::= { aprisaXETxVtuneHiAlarm 5 } aprisaXETxVtuneHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxVtuneHiAlarmStatus, aprisaXETxVtuneHiAlarmSeverity, aprisaXETxVtuneHiAlarmEnabled, aprisaXETxVtuneHiAlarmThreshold, aprisaXETxVtuneHiAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE transmitter VTUNE too high alarm group." ::= { aprisaXEGroups 96 } aprisaXETxVtuneLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 10 } aprisaXETxVtuneLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the transmitter VTUNE too low alarm." ::= { aprisaXETxVtuneLoAlarm 1 } aprisaXETxVtuneLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the transmitter VTUNE too low alarm." ::= { aprisaXETxVtuneLoAlarm 2 } aprisaXETxVtuneLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the transmitter VTUNE too low alarm is enabled." ::= { aprisaXETxVtuneLoAlarm 3 } aprisaXETxVtuneLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter VTUNE too low alarm will be set." ::= { aprisaXETxVtuneLoAlarm 4 } aprisaXETxVtuneLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter VTUNE too low will be cleared." ::= { aprisaXETxVtuneLoAlarm 5 } aprisaXETxVtuneLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxVtuneLoAlarmStatus, aprisaXETxVtuneLoAlarmSeverity, aprisaXETxVtuneLoAlarmEnabled, aprisaXETxVtuneLoAlarmThreshold, aprisaXETxVtuneLoAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE transmitter VTUNE too low alarm group." ::= { aprisaXEGroups 101 } aprisaXETx5VDigHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 11 } aprisaXETx5VDigHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the transmitter 5V digital voltage too high alarm." ::= { aprisaXETx5VDigHiAlarm 1 } aprisaXETx5VDigHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the transmitter 5V digital voltage too high alarm." ::= { aprisaXETx5VDigHiAlarm 2 } aprisaXETx5VDigHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the transmitter 5V digital voltage too high alarm is enabled." ::= { aprisaXETx5VDigHiAlarm 3 } aprisaXETx5VDigHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter 5V digital voltage too high alarm will be set." ::= { aprisaXETx5VDigHiAlarm 4 } aprisaXETx5VDigHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter 5V digital voltage too high will be cleared." ::= { aprisaXETx5VDigHiAlarm 5 } aprisaXETx5VDigHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETx5VDigHiAlarmStatus, aprisaXETx5VDigHiAlarmSeverity, aprisaXETx5VDigHiAlarmEnabled, aprisaXETx5VDigHiAlarmThreshold, aprisaXETx5VDigHiAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE transmitter 5V digital voltage too high alarm group." ::= { aprisaXEGroups 106 } aprisaXETx5VDigLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 12 } aprisaXETx5VDigLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the transmitter 5V digital voltage too low alarm." ::= { aprisaXETx5VDigLoAlarm 1 } aprisaXETx5VDigLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the transmitter 5V digital voltage too low alarm." ::= { aprisaXETx5VDigLoAlarm 2 } aprisaXETx5VDigLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the transmitter 5V digital voltage too low alarm is enabled." ::= { aprisaXETx5VDigLoAlarm 3 } aprisaXETx5VDigLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter 5V digital voltage too low alarm will be set." ::= { aprisaXETx5VDigLoAlarm 4 } aprisaXETx5VDigLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter 5V digital voltage too low will be cleared." ::= { aprisaXETx5VDigLoAlarm 5 } aprisaXETx5VDigLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETx5VDigLoAlarmStatus, aprisaXETx5VDigLoAlarmSeverity, aprisaXETx5VDigLoAlarmEnabled, aprisaXETx5VDigLoAlarmThreshold, aprisaXETx5VDigLoAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE transmitter 5V digital voltage too low alarm group." ::= { aprisaXEGroups 111 } aprisaXETx7VRfHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 13 } aprisaXETx7VRfHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the transmitter 7V RF voltage too high alarm." ::= { aprisaXETx7VRfHiAlarm 1 } aprisaXETx7VRfHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the transmitter 7V RF voltage too high alarm." ::= { aprisaXETx7VRfHiAlarm 2 } aprisaXETx7VRfHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the transmitter 7V RF voltage too high alarm is enabled." ::= { aprisaXETx7VRfHiAlarm 3 } aprisaXETx7VRfHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter 7V RF voltage too high alarm will be set." ::= { aprisaXETx7VRfHiAlarm 4 } aprisaXETx7VRfHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter 7V RF voltage too high will be cleared." ::= { aprisaXETx7VRfHiAlarm 5 } aprisaXETx7VRfHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETx7VRfHiAlarmStatus, aprisaXETx7VRfHiAlarmSeverity, aprisaXETx7VRfHiAlarmEnabled, aprisaXETx7VRfHiAlarmThreshold, aprisaXETx7VRfHiAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE transmitter 7V RF voltage too high alarm group." ::= { aprisaXEGroups 116 } aprisaXETx7VRfLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 14 } aprisaXETx7VRfLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the transmitter 7V RF voltage too low alarm." ::= { aprisaXETx7VRfLoAlarm 1 } aprisaXETx7VRfLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the transmitter 7V RF voltage too low alarm." ::= { aprisaXETx7VRfLoAlarm 2 } aprisaXETx7VRfLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the transmitter 7V RF voltage too low alarm is enabled." ::= { aprisaXETx7VRfLoAlarm 3 } aprisaXETx7VRfLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter 7V RF voltage too low alarm will be set." ::= { aprisaXETx7VRfLoAlarm 4 } aprisaXETx7VRfLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter 7V RF voltage too low will be cleared." ::= { aprisaXETx7VRfLoAlarm 5 } aprisaXETx7VRfLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETx7VRfLoAlarmStatus, aprisaXETx7VRfLoAlarmSeverity, aprisaXETx7VRfLoAlarmEnabled, aprisaXETx7VRfLoAlarmThreshold, aprisaXETx7VRfLoAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE transmitter 7V RF voltage too low alarm group." ::= { aprisaXEGroups 121 } aprisaXETx9VHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 15 } aprisaXETx9VHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the transmitter 9V voltage too high alarm." ::= { aprisaXETx9VHiAlarm 1 } aprisaXETx9VHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the transmitter 9V voltage too high alarm." ::= { aprisaXETx9VHiAlarm 2 } aprisaXETx9VHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the transmitter 9V voltage too high alarm is enabled." ::= { aprisaXETx9VHiAlarm 3 } aprisaXETx9VHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter 9V voltage too high alarm will be set." ::= { aprisaXETx9VHiAlarm 4 } aprisaXETx9VHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter 9V voltage too high will be cleared." ::= { aprisaXETx9VHiAlarm 5 } aprisaXETx9VHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETx9VHiAlarmStatus, aprisaXETx9VHiAlarmSeverity, aprisaXETx9VHiAlarmEnabled, aprisaXETx9VHiAlarmThreshold, aprisaXETx9VHiAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE transmitter 9V voltage too high alarm group." ::= { aprisaXEGroups 126 } aprisaXETx9VLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 16 } aprisaXETx9VLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the transmitter 9V voltage too low alarm." ::= { aprisaXETx9VLoAlarm 1 } aprisaXETx9VLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the transmitter 9V voltage too low alarm." ::= { aprisaXETx9VLoAlarm 2 } aprisaXETx9VLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the transmitter 9V voltage too low alarm is enabled." ::= { aprisaXETx9VLoAlarm 3 } aprisaXETx9VLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter 9V voltage too low alarm will be set." ::= { aprisaXETx9VLoAlarm 4 } aprisaXETx9VLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter 9V voltage too low will be cleared." ::= { aprisaXETx9VLoAlarm 5 } aprisaXETx9VLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETx9VLoAlarmStatus, aprisaXETx9VLoAlarmSeverity, aprisaXETx9VLoAlarmEnabled, aprisaXETx9VLoAlarmThreshold, aprisaXETx9VLoAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE transmitter 9V voltage too low alarm group." ::= { aprisaXEGroups 131 } aprisaXETx11VHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 17 } aprisaXETx11VHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the transmitter 11V voltage too high alarm." ::= { aprisaXETx11VHiAlarm 1 } aprisaXETx11VHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the transmitter 11V voltage too high alarm." ::= { aprisaXETx11VHiAlarm 2 } aprisaXETx11VHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the transmitter 11V voltage too high alarm is enabled." ::= { aprisaXETx11VHiAlarm 3 } aprisaXETx11VHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter 11V voltage too high alarm will be set." ::= { aprisaXETx11VHiAlarm 4 } aprisaXETx11VHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter 11V voltage too high will be cleared." ::= { aprisaXETx11VHiAlarm 5 } aprisaXETx11VHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETx11VHiAlarmStatus, aprisaXETx11VHiAlarmSeverity, aprisaXETx11VHiAlarmEnabled, aprisaXETx11VHiAlarmThreshold, aprisaXETx11VHiAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE transmitter 11V voltage too high alarm group." ::= { aprisaXEGroups 136 } aprisaXETx11VLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 18 } aprisaXETx11VLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the transmitter 11V voltage too low alarm." ::= { aprisaXETx11VLoAlarm 1 } aprisaXETx11VLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the transmitter 11V voltage too low alarm." ::= { aprisaXETx11VLoAlarm 2 } aprisaXETx11VLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the transmitter 11V voltage too low alarm is enabled." ::= { aprisaXETx11VLoAlarm 3 } aprisaXETx11VLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter 11V voltage too low alarm will be set." ::= { aprisaXETx11VLoAlarm 4 } aprisaXETx11VLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter 11V voltage too low will be cleared." ::= { aprisaXETx11VLoAlarm 5 } aprisaXETx11VLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETx11VLoAlarmStatus, aprisaXETx11VLoAlarmSeverity, aprisaXETx11VLoAlarmEnabled, aprisaXETx11VLoAlarmThreshold, aprisaXETx11VLoAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE transmitter 11V voltage too low alarm group." ::= { aprisaXEGroups 141 } aprisaXETx28VHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 19 } aprisaXETx28VHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the transmitter 28V voltage too high alarm." ::= { aprisaXETx28VHiAlarm 1 } aprisaXETx28VHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the transmitter 28V voltage too high alarm." ::= { aprisaXETx28VHiAlarm 2 } aprisaXETx28VHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the transmitter 28V voltage too high alarm is enabled." ::= { aprisaXETx28VHiAlarm 3 } aprisaXETx28VHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter 28V voltage too high alarm will be set." ::= { aprisaXETx28VHiAlarm 4 } aprisaXETx28VHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter 28V voltage too high will be cleared." ::= { aprisaXETx28VHiAlarm 5 } aprisaXETx28VHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETx28VHiAlarmStatus, aprisaXETx28VHiAlarmSeverity, aprisaXETx28VHiAlarmEnabled, aprisaXETx28VHiAlarmThreshold, aprisaXETx28VHiAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE transmitter 28V voltage too high alarm group." ::= { aprisaXEGroups 146 } aprisaXETx28VLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 20 } aprisaXETx28VLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the transmitter 28V voltage too low alarm." ::= { aprisaXETx28VLoAlarm 1 } aprisaXETx28VLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the transmitter 28V voltage too low alarm." ::= { aprisaXETx28VLoAlarm 2 } aprisaXETx28VLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the transmitter 28V voltage too low alarm is enabled." ::= { aprisaXETx28VLoAlarm 3 } aprisaXETx28VLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter 28V voltage too low alarm will be set." ::= { aprisaXETx28VLoAlarm 4 } aprisaXETx28VLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the transmitter 28V voltage too low will be cleared." ::= { aprisaXETx28VLoAlarm 5 } aprisaXETx28VLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETx28VLoAlarmStatus, aprisaXETx28VLoAlarmSeverity, aprisaXETx28VLoAlarmEnabled, aprisaXETx28VLoAlarmThreshold, aprisaXETx28VLoAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE transmitter 28V voltage too low alarm group." ::= { aprisaXEGroups 151 } -- -- Transmitter synthesiser out of lock alarm -- aprisaXETxSynthOutOfLockAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 21 } aprisaXETxSynthOutOfLockAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the TX synth out of lock alarm." ::= { aprisaXETxSynthOutOfLockAlarm 1 } aprisaXETxSynthOutOfLockAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the TX synth out of lock alarm." ::= { aprisaXETxSynthOutOfLockAlarm 2 } aprisaXETxSynthOutOfLockAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the TX synth out of lock alarm is enabled." ::= { aprisaXETxSynthOutOfLockAlarm 3 } aprisaXETxSynthOutOfLockAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxSynthOutOfLockAlarmStatus, aprisaXETxSynthOutOfLockAlarmSeverity, aprisaXETxSynthOutOfLockAlarmEnabled } STATUS current DESCRIPTION "The AprisaXE TX Synth out of lock alarm group." ::= { aprisaXEGroups 153 } -- -- Return Loss Too High Alarm -- -- The threshold values vary according to the currently selected modulation. -- aprisaXEReturnLossHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 22 } aprisaXEReturnLossHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the return loss out of limits alarm." ::= { aprisaXEReturnLossHiAlarm 1 } aprisaXEReturnLossHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the return loss out of limits alarm." ::= { aprisaXEReturnLossHiAlarm 2 } aprisaXEReturnLossHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the return loss out of limits alarm is enabled." ::= { aprisaXEReturnLossHiAlarm 3 } aprisaXEReturnLossHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the level at which the return loss alarm will be set." ::= { aprisaXEReturnLossHiAlarm 4 } aprisaXEReturnLossHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the level at which the return loss alarm will be cleared." ::= { aprisaXEReturnLossHiAlarm 5 } aprisaXEReturnLossHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXEReturnLossHiAlarmStatus, aprisaXEReturnLossHiAlarmSeverity, aprisaXEReturnLossHiAlarmEnabled, aprisaXEReturnLossHiAlarmThreshold, aprisaXEReturnLossHiAlarmClearThreshold } STATUS current DESCRIPTION "The AprisaXE reverse power too high alarm group." ::= { aprisaXEGroups 152 } -- *************************************************************************** -- End of Transmitter alarms -- *************************************************************************** -- *************************************************************************** -- The Receiver alarms -- *************************************************************************** aprisaXEReceiverAlarms OBJECT IDENTIFIER ::= { aprisaXELinkAlarms 6 } -- Rx Synthesizer out of lock aprisaXERxSynthOutOfLockAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 1 } aprisaXERxSynthOutOfLockAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the Synth out of lock alarm." ::= { aprisaXERxSynthOutOfLockAlarm 1 } aprisaXERxSynthOutOfLockAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the Synth out of lock alarm." ::= { aprisaXERxSynthOutOfLockAlarm 2 } aprisaXERxSynthOutOfLockAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the Synth out of lock alarm is enabled." ::= { aprisaXERxSynthOutOfLockAlarm 3 } aprisaXERxSynthOutOfLockAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxSynthOutOfLockAlarmStatus, aprisaXERxSynthOutOfLockAlarmSeverity, aprisaXERxSynthOutOfLockAlarmEnabled } STATUS current DESCRIPTION "The AprisaXE Synth out of lock alarm group." ::= { aprisaXEGroups 161 } -- -- 12 V alarm -- aprisaXERx12VAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 3 } aprisaXERx12VAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the 12V supply alarm." ::= { aprisaXERx12VAlarm 1 } aprisaXERx12VAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the 12V supply aprisaXERxVtuneLoAlarmalarm." ::= { aprisaXERx12VAlarm 2 } aprisaXERx12VAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the 12V supply alarm is enabled." ::= { aprisaXERx12VAlarm 3 } aprisaXERx12VAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERx12VAlarmStatus, aprisaXERx12VAlarmSeverity, aprisaXERx12VAlarmEnabled } STATUS current DESCRIPTION "The AprisaXE 12V supply alarm group." ::= { aprisaXEGroups 166 } -- -- 3.3V high alarm -- aprisaXERx3V3HiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 4 } aprisaXERx3V3HiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the 3.3V supply high alarm." ::= { aprisaXERx3V3HiAlarm 1 } aprisaXERx3V3HiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the 3.3V supply high alarm." ::= { aprisaXERx3V3HiAlarm 2 } aprisaXERx3V3HiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the 3.3V supply high alarm is enabled." ::= { aprisaXERx3V3HiAlarm 3 } aprisaXERx3V3HiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the 3.3V supply high alarm will be set." ::= { aprisaXERx3V3HiAlarm 4 } aprisaXERx3V3HiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the 3.3V supply high will be cleared." ::= { aprisaXERx3V3HiAlarm 5 } aprisaXERx3V3HiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERx3V3HiAlarmStatus, aprisaXERx3V3HiAlarmSeverity, aprisaXERx3V3HiAlarmEnabled, aprisaXERx3V3HiAlarmThreshold, aprisaXERx3V3HiAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE 3.3V supply high alarm group." ::= { aprisaXEGroups 171 } -- --3.3V low alarm -- aprisaXERx3V3LoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 5 } aprisaXERx3V3LoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the 3.3V supply low alarm." ::= { aprisaXERx3V3LoAlarm 1 } aprisaXERx3V3LoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the 3.3V supply low alarm." ::= { aprisaXERx3V3LoAlarm 2 } aprisaXERx3V3LoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the 3.3V supply low alarm is enabled." ::= { aprisaXERx3V3LoAlarm 3 } aprisaXERx3V3LoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the 3.3V supply low alarm will be set." ::= { aprisaXERx3V3LoAlarm 4 } aprisaXERx3V3LoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the 3.3V supply low will be cleared." ::= { aprisaXERx3V3LoAlarm 5 } aprisaXERx3V3LoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERx3V3LoAlarmStatus, aprisaXERx3V3LoAlarmSeverity, aprisaXERx3V3LoAlarmEnabled, aprisaXERx3V3LoAlarmThreshold, aprisaXERx3V3LoAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE 3.3V supply low alarm group." ::= { aprisaXEGroups 176 } -- -- 5V high alarm -- aprisaXERx5VHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 6 } aprisaXERx5VHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the 5V supply High alarm." ::= { aprisaXERx5VHiAlarm 1 } aprisaXERx5VHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the 5V supply High alarm." ::= { aprisaXERx5VHiAlarm 2 } aprisaXERx5VHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the 5V supply High alarm is enabled." ::= { aprisaXERx5VHiAlarm 3 } aprisaXERx5VHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the 5V supply High alarm will be set." ::= { aprisaXERx5VHiAlarm 4 } aprisaXERx5VHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the 5V supply High will be cleared." ::= { aprisaXERx5VHiAlarm 5 } aprisaXERx5VHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERx5VHiAlarmStatus, aprisaXERx5VHiAlarmSeverity, aprisaXERx5VHiAlarmEnabled, aprisaXERx5VHiAlarmThreshold, aprisaXERx5VHiAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE 5V supply High alarm group." ::= { aprisaXEGroups 181 } -- --5V low alarm -- aprisaXERx5VLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 7 } aprisaXERx5VLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the 5V supply low alarm." ::= { aprisaXERx5VLoAlarm 1 } aprisaXERx5VLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the 5V supply low alarm." ::= { aprisaXERx5VLoAlarm 2 } aprisaXERx5VLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the 5V supply low alarm is enabled." ::= { aprisaXERx5VLoAlarm 3 } aprisaXERx5VLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the 5V supply low alarm will be set." ::= { aprisaXERx5VLoAlarm 4 } aprisaXERx5VLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the 5V supply low will be cleared." ::= { aprisaXERx5VLoAlarm 5 } aprisaXERx5VLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERx5VLoAlarmStatus, aprisaXERx5VLoAlarmSeverity, aprisaXERx5VLoAlarmEnabled, aprisaXERx5VLoAlarmThreshold, aprisaXERx5VLoAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE 5V supply low alarm group." ::= { aprisaXEGroups 186 } -- -- 9V high alarm -- aprisaXERx9VHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 8 } aprisaXERx9VHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the 9V supply High alarm." ::= { aprisaXERx9VHiAlarm 1 } aprisaXERx9VHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the 9V supply High alarm." ::= { aprisaXERx9VHiAlarm 2 } aprisaXERx9VHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the 9V supply High alarm is enabled." ::= { aprisaXERx9VHiAlarm 3 } aprisaXERx9VHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the 9V supply High alarm will be set." ::= { aprisaXERx9VHiAlarm 4 } aprisaXERx9VHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the 9V supply High will be cleared." ::= { aprisaXERx9VHiAlarm 5 } aprisaXERx9VHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERx9VHiAlarmStatus, aprisaXERx9VHiAlarmSeverity, aprisaXERx9VHiAlarmEnabled, aprisaXERx9VHiAlarmThreshold, aprisaXERx9VHiAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE 9V supply High alarm group." ::= { aprisaXEGroups 191 } -- -- 9V low alarm -- aprisaXERx9VLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 9 } aprisaXERx9VLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the 9V supply low alarm." ::= { aprisaXERx9VLoAlarm 1 } aprisaXERx9VLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the 9V supply low alarm." ::= { aprisaXERx9VLoAlarm 2 } aprisaXERx9VLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the 9V supply low alarm is enabled." ::= { aprisaXERx9VLoAlarm 3 } aprisaXERx9VLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the 9V supply low alarm will be set." ::= { aprisaXERx9VLoAlarm 4 } aprisaXERx9VLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the 9V supply low will be cleared." ::= { aprisaXERx9VLoAlarm 5 } aprisaXERx9VLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERx9VLoAlarmStatus, aprisaXERx9VLoAlarmSeverity, aprisaXERx9VLoAlarmEnabled, aprisaXERx9VLoAlarmThreshold, aprisaXERx9VLoAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE 9V supply low alarm group." ::= { aprisaXEGroups 196 } -- -- Neg 1V5 high alarm -- aprisaXERxNeg1V5HiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 10 } aprisaXERxNeg1V5HiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the Neg 1.5V supply High alarm." ::= { aprisaXERxNeg1V5HiAlarm 1 } aprisaXERxNeg1V5HiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the Neg 1.5V supply High alarm." ::= { aprisaXERxNeg1V5HiAlarm 2 } aprisaXERxNeg1V5HiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the Neg 1.5V supply High alarm is enabled." ::= { aprisaXERxNeg1V5HiAlarm 3 } aprisaXERxNeg1V5HiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the Neg 1.5V supply High alarm will be set." ::= { aprisaXERxNeg1V5HiAlarm 4 } aprisaXERxNeg1V5HiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the Neg 1.5V supply High will be cleared." ::= { aprisaXERxNeg1V5HiAlarm 5 } aprisaXERxNeg1V5HiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxNeg1V5HiAlarmStatus, aprisaXERxNeg1V5HiAlarmSeverity, aprisaXERxNeg1V5HiAlarmEnabled, aprisaXERxNeg1V5HiAlarmThreshold, aprisaXERxNeg1V5HiAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE Neg 1.5V supply High alarm group." ::= { aprisaXEGroups 201 } -- -- Neg 1V5 low alarm -- aprisaXERxNeg1V5LoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 11 } aprisaXERxNeg1V5LoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the Neg 1.5V supply low alarm." ::= { aprisaXERxNeg1V5LoAlarm 1 } aprisaXERxNeg1V5LoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the Neg 1.5V supply low alarm." ::= { aprisaXERxNeg1V5LoAlarm 2 } aprisaXERxNeg1V5LoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the Neg 1.5V supply low alarm is enabled." ::= { aprisaXERxNeg1V5LoAlarm 3 } aprisaXERxNeg1V5LoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the Neg 1.5V supply low alarm will be set." ::= { aprisaXERxNeg1V5LoAlarm 4 } aprisaXERxNeg1V5LoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the Neg 1.5V supply low will be cleared." ::= { aprisaXERxNeg1V5LoAlarm 5 } aprisaXERxNeg1V5LoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxNeg1V5LoAlarmStatus, aprisaXERxNeg1V5LoAlarmSeverity, aprisaXERxNeg1V5LoAlarmEnabled, aprisaXERxNeg1V5LoAlarmThreshold, aprisaXERxNeg1V5LoAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE Neg 1.5V supply low alarm group." ::= { aprisaXEGroups 206 } -- -- AGC high alarm -- aprisaXERxAgcHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 12 } aprisaXERxAgcHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the AGC high alarm." ::= { aprisaXERxAgcHiAlarm 1 } aprisaXERxAgcHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the AGC high alarm." ::= { aprisaXERxAgcHiAlarm 2 } aprisaXERxAgcHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the AGC high alarm is enabled." ::= { aprisaXERxAgcHiAlarm 3 } aprisaXERxAgcHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the AGC high alarm will be set." ::= { aprisaXERxAgcHiAlarm 4 } aprisaXERxAgcHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the AGC high will be cleared." ::= { aprisaXERxAgcHiAlarm 5 } aprisaXERxAgcHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxAgcHiAlarmStatus, aprisaXERxAgcHiAlarmSeverity, aprisaXERxAgcHiAlarmEnabled, aprisaXERxAgcHiAlarmThreshold, aprisaXERxAgcHiAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE AGC high alarm group." ::= { aprisaXEGroups 211 } -- --AGC low alarm -- aprisaXERxAgcLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 13 } aprisaXERxAgcLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the AGC low alarm." ::= { aprisaXERxAgcLoAlarm 1 } aprisaXERxAgcLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the AGC low alarm." ::= { aprisaXERxAgcLoAlarm 2 } aprisaXERxAgcLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the AGC low alarm is enabled." ::= { aprisaXERxAgcLoAlarm 3 } aprisaXERxAgcLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the AGC low alarm will be set." ::= { aprisaXERxAgcLoAlarm 4 } aprisaXERxAgcLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the AGC low will be cleared." ::= { aprisaXERxAgcLoAlarm 5 } aprisaXERxAgcLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxAgcLoAlarmStatus, aprisaXERxAgcLoAlarmSeverity, aprisaXERxAgcLoAlarmEnabled, aprisaXERxAgcLoAlarmThreshold, aprisaXERxAgcLoAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE AGC low alarm group." ::= { aprisaXEGroups 216 } -- -- RSSI High alarm -- aprisaXERxRssiHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 14 } aprisaXERxRssiHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the RSSI High alarm." ::= { aprisaXERxRssiHiAlarm 1 } aprisaXERxRssiHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the RSSI High alarm." ::= { aprisaXERxRssiHiAlarm 2 } aprisaXERxRssiHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the RSSI High alarm is enabled." ::= { aprisaXERxRssiHiAlarm 3 } aprisaXERxRssiHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the RSSI High alarm will be set." ::= { aprisaXERxRssiHiAlarm 4 } aprisaXERxRssiHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the RSSI High will be cleared." ::= { aprisaXERxRssiHiAlarm 5 } aprisaXERxRssiHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxRssiHiAlarmStatus, aprisaXERxRssiHiAlarmSeverity, aprisaXERxRssiHiAlarmEnabled, aprisaXERxRssiHiAlarmThreshold, aprisaXERxRssiHiAlarmClearThreshold } STATUS current DESCRIPTION "The AprisaXE RSSI High alarm group." ::= { aprisaXEGroups 221 } -- -- RSSI low alarms -- aprisaXERxRssiLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 15 } aprisaXERxRssiLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the RSSI low alarm." ::= { aprisaXERxRssiLoAlarm 1 } aprisaXERxRssiLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the RSSI low alarm." ::= { aprisaXERxRssiLoAlarm 2 } aprisaXERxRssiLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the RSSI low alarm is enabled." ::= { aprisaXERxRssiLoAlarm 3 } aprisaXERxRssiLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the RSSI low alarm will be set." ::= { aprisaXERxRssiLoAlarm 4 } aprisaXERxRssiLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the RSSI low will be cleared." ::= { aprisaXERxRssiLoAlarm 5 } aprisaXERxRssiLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxRssiLoAlarmStatus, aprisaXERxRssiLoAlarmSeverity, aprisaXERxRssiLoAlarmEnabled, aprisaXERxRssiLoAlarmThreshold, aprisaXERxRssiLoAlarmClearThreshold } STATUS current DESCRIPTION "The AprisaXE RSSI low alarm group." ::= { aprisaXEGroups 226 } -- -- VTune High Alarm -- aprisaXERxVtuneHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 16 } aprisaXERxVtuneHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the Vtune High alarm." ::= { aprisaXERxVtuneHiAlarm 1 } aprisaXERxVtuneHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the Vtune High alarm." ::= { aprisaXERxVtuneHiAlarm 2 } aprisaXERxVtuneHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the Vtune High alarm is enabled." ::= { aprisaXERxVtuneHiAlarm 3 } aprisaXERxVtuneHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the Vtune High alarm will be set." ::= { aprisaXERxVtuneHiAlarm 4 } aprisaXERxVtuneHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the Vtune High will be cleared." ::= { aprisaXERxVtuneHiAlarm 5 } aprisaXERxVtuneHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxVtuneHiAlarmStatus, aprisaXERxVtuneHiAlarmSeverity, aprisaXERxVtuneHiAlarmEnabled, aprisaXERxVtuneHiAlarmThreshold, aprisaXERxVtuneHiAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE Vtune High alarm group." ::= { aprisaXEGroups 231 } -- --Vtune low alarm -- aprisaXERxVtuneLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 17 } aprisaXERxVtuneLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The status of the Vtune low alarm." ::= { aprisaXERxVtuneLoAlarm 1 } aprisaXERxVtuneLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The severity of the Vtune low alarm." ::= { aprisaXERxVtuneLoAlarm 2 } aprisaXERxVtuneLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates whether the Vtune low alarm is enabled." ::= { aprisaXERxVtuneLoAlarm 3 } aprisaXERxVtuneLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the Vtune low alarm will be set." ::= { aprisaXERxVtuneLoAlarm 4 } aprisaXERxVtuneLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the level at which the Vtune low will be cleared." ::= { aprisaXERxVtuneLoAlarm 5 } aprisaXERxVtuneLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxVtuneLoAlarmStatus, aprisaXERxVtuneLoAlarmSeverity, aprisaXERxVtuneLoAlarmEnabled, aprisaXERxVtuneLoAlarmThreshold, aprisaXERxVtuneLoAlarmClearThreshold } STATUS obsolete DESCRIPTION "The AprisaXE Vtune low alarm group." ::= { aprisaXEGroups 236 } -- -- EE Alarm -- aprisaXERxEEAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 18 } aprisaXERxEEAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the EEPROM alarm." ::= { aprisaXERxEEAlarm 1 } aprisaXERxEEAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the EEPROM alarm." ::= { aprisaXERxEEAlarm 2 } aprisaXERxEEAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the EEPROM alarm is enabled." ::= { aprisaXERxEEAlarm 3 } aprisaXERxEEAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxEEAlarmStatus, aprisaXERxEEAlarmSeverity, aprisaXERxEEAlarmEnabled } STATUS current DESCRIPTION "The AprisaXE EEPROM alarm group." ::= { aprisaXEGroups 241 } -- *************************************************************************** -- End of Receiver alarms -- *************************************************************************** -- *************************************************************************** -- The Generic Transmitter Alarms -- *************************************************************************** aprisaXETxADCChZeroHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 23 } aprisaXETxADCChZeroHiAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the transmitter ADC Ch Zero voltage too high alarm." ::= { aprisaXETxADCChZeroHiAlarm 1 } aprisaXETxADCChZeroHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter ADC Ch Zero voltage too high alarm." ::= { aprisaXETxADCChZeroHiAlarm 2 } aprisaXETxADCChZeroHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the transmitter ADC Ch Zero voltage too high alarm." ::= { aprisaXETxADCChZeroHiAlarm 3 } aprisaXETxADCChZeroHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the transmitter ADC Ch Zero voltage too high alarm is enabled." ::= { aprisaXETxADCChZeroHiAlarm 4 } aprisaXETxADCChZeroHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the transmitter ADC Ch Zero voltage too high alarm will be set." ::= { aprisaXETxADCChZeroHiAlarm 5 } aprisaXETxADCChZeroHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the transmitter ADC Ch Zero voltage too high will be cleared." ::= { aprisaXETxADCChZeroHiAlarm 6 } aprisaXETxADCChZeroHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxADCChZeroHiAlarmName, aprisaXETxADCChZeroHiAlarmStatus, aprisaXETxADCChZeroHiAlarmSeverity, aprisaXETxADCChZeroHiAlarmEnabled, aprisaXETxADCChZeroHiAlarmThreshold, aprisaXETxADCChZeroHiAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXETx transmitter ADC Ch Zero voltage too high alarm group." ::= { aprisaXEGroups 250 } aprisaXETxADCChZeroLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 24 } aprisaXETxADCChZeroLoAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the transmitter ADC Ch Zero voltage too low alarm." ::= { aprisaXETxADCChZeroLoAlarm 1 } aprisaXETxADCChZeroLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter ADC Ch Zero voltage too low alarm." ::= { aprisaXETxADCChZeroLoAlarm 2 } aprisaXETxADCChZeroLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the transmitter ADC Ch Zero voltage too low alarm." ::= { aprisaXETxADCChZeroLoAlarm 3 } aprisaXETxADCChZeroLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the transmitter ADC Ch Zero voltage too low alarm is enabled." ::= { aprisaXETxADCChZeroLoAlarm 4 } aprisaXETxADCChZeroLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Zero voltage too low alarm will be set." ::= { aprisaXETxADCChZeroLoAlarm 5 } aprisaXETxADCChZeroLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Zero voltage too low will be cleared." ::= { aprisaXETxADCChZeroLoAlarm 6 } aprisaXETxADCChZeroLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxADCChZeroLoAlarmName, aprisaXETxADCChZeroLoAlarmStatus, aprisaXETxADCChZeroLoAlarmSeverity, aprisaXETxADCChZeroLoAlarmEnabled, aprisaXETxADCChZeroLoAlarmThreshold, aprisaXETxADCChZeroLoAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXETx transmitter ADC Ch Zero voltage too High alarm group." ::= { aprisaXEGroups 251 } aprisaXETxADCChOneHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 25 } aprisaXETxADCChOneHiAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the transmitter ADC Ch One voltage too high alarm." ::= { aprisaXETxADCChOneHiAlarm 1 } aprisaXETxADCChOneHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter ADC Ch One voltage too high alarm." ::= { aprisaXETxADCChOneHiAlarm 2 } aprisaXETxADCChOneHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the transmitter ADC Ch One voltage too high alarm." ::= { aprisaXETxADCChOneHiAlarm 3 } aprisaXETxADCChOneHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the transmitter ADC Ch One voltage too high alarm is enabled." ::= { aprisaXETxADCChOneHiAlarm 4 } aprisaXETxADCChOneHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the transmitter ADC Ch One voltage too high alarm will be set." ::= { aprisaXETxADCChOneHiAlarm 5 } aprisaXETxADCChOneHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the transmitter ADC Ch One voltage too high will be cleared." ::= { aprisaXETxADCChOneHiAlarm 6 } aprisaXETxADCChOneHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxADCChOneHiAlarmName, aprisaXETxADCChOneHiAlarmStatus, aprisaXETxADCChOneHiAlarmSeverity, aprisaXETxADCChOneHiAlarmEnabled, aprisaXETxADCChOneHiAlarmThreshold, aprisaXETxADCChOneHiAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXETx transmitter ADC Ch One voltage too high alarm group." ::= { aprisaXEGroups 252 } aprisaXETxADCChOneLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 26 } aprisaXETxADCChOneLoAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the transmitter ADC Ch One voltage too low alarm." ::= { aprisaXETxADCChOneLoAlarm 1 } aprisaXETxADCChOneLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter ADC Ch One voltage too low alarm." ::= { aprisaXETxADCChOneLoAlarm 2 } aprisaXETxADCChOneLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the transmitter ADC Ch One voltage too low alarm." ::= { aprisaXETxADCChOneLoAlarm 3 } aprisaXETxADCChOneLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the transmitter ADC Ch One voltage too low alarm is enabled." ::= { aprisaXETxADCChOneLoAlarm 4 } aprisaXETxADCChOneLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch One voltage too low alarm will be set." ::= { aprisaXETxADCChOneLoAlarm 5 } aprisaXETxADCChOneLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch One voltage too low will be cleared." ::= { aprisaXETxADCChOneLoAlarm 6 } aprisaXETxADCChOneLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxADCChOneLoAlarmName, aprisaXETxADCChOneLoAlarmStatus, aprisaXETxADCChOneLoAlarmSeverity, aprisaXETxADCChOneLoAlarmEnabled, aprisaXETxADCChOneLoAlarmThreshold, aprisaXETxADCChOneLoAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXETx transmitter ADC Ch One voltage too High alarm group." ::= { aprisaXEGroups 253 } aprisaXETxADCChTwoHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 27 } aprisaXETxADCChTwoHiAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the transmitter ADC Ch Two voltage too high alarm." ::= { aprisaXETxADCChTwoHiAlarm 1 } aprisaXETxADCChTwoHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter ADC Ch Two voltage too high alarm." ::= { aprisaXETxADCChTwoHiAlarm 2 } aprisaXETxADCChTwoHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the transmitter ADC Ch Two voltage too high alarm." ::= { aprisaXETxADCChTwoHiAlarm 3 } aprisaXETxADCChTwoHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the transmitter ADC Ch Two voltage too high alarm is enabled." ::= { aprisaXETxADCChTwoHiAlarm 4 } aprisaXETxADCChTwoHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the transmitter ADC Ch Two voltage too high alarm will be set." ::= { aprisaXETxADCChTwoHiAlarm 5 } aprisaXETxADCChTwoHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the transmitter ADC Ch Two voltage too high will be cleared." ::= { aprisaXETxADCChTwoHiAlarm 6 } aprisaXETxADCChTwoHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxADCChTwoHiAlarmName, aprisaXETxADCChTwoHiAlarmStatus, aprisaXETxADCChTwoHiAlarmSeverity, aprisaXETxADCChTwoHiAlarmEnabled, aprisaXETxADCChTwoHiAlarmThreshold, aprisaXETxADCChTwoHiAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXETx transmitter ADC Ch Two voltage too high alarm group." ::= { aprisaXEGroups 254 } aprisaXETxADCChTwoLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 28 } aprisaXETxADCChTwoLoAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the transmitter ADC Ch Two voltage too low alarm." ::= { aprisaXETxADCChTwoLoAlarm 1 } aprisaXETxADCChTwoLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter ADC Ch Two voltage too low alarm." ::= { aprisaXETxADCChTwoLoAlarm 2 } aprisaXETxADCChTwoLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the transmitter ADC Ch Two voltage too low alarm." ::= { aprisaXETxADCChTwoLoAlarm 3 } aprisaXETxADCChTwoLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the transmitter ADC Ch Two voltage too low alarm is enabled." ::= { aprisaXETxADCChTwoLoAlarm 4 } aprisaXETxADCChTwoLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Two voltage too low alarm will be set." ::= { aprisaXETxADCChTwoLoAlarm 5 } aprisaXETxADCChTwoLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Two voltage too low will be cleared." ::= { aprisaXETxADCChTwoLoAlarm 6 } aprisaXETxADCChTwoLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxADCChTwoLoAlarmName, aprisaXETxADCChTwoLoAlarmStatus, aprisaXETxADCChTwoLoAlarmSeverity, aprisaXETxADCChTwoLoAlarmEnabled, aprisaXETxADCChTwoLoAlarmThreshold, aprisaXETxADCChTwoLoAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXETx transmitter ADC Ch Two voltage too High alarm group." ::= { aprisaXEGroups 255 } aprisaXETxADCChThreeHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 29 } aprisaXETxADCChThreeHiAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the transmitter ADC Ch Three voltage too high alarm." ::= { aprisaXETxADCChThreeHiAlarm 1 } aprisaXETxADCChThreeHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter ADC Ch Three voltage too high alarm." ::= { aprisaXETxADCChThreeHiAlarm 2 } aprisaXETxADCChThreeHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the transmitter ADC Ch Three voltage too high alarm." ::= { aprisaXETxADCChThreeHiAlarm 3 } aprisaXETxADCChThreeHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the transmitter ADC Ch Three voltage too high alarm is enabled." ::= { aprisaXETxADCChThreeHiAlarm 4 } aprisaXETxADCChThreeHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the transmitter ADC Ch Three voltage too high alarm will be set." ::= { aprisaXETxADCChThreeHiAlarm 5 } aprisaXETxADCChThreeHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the transmitter ADC Ch Three voltage too high will be cleared." ::= { aprisaXETxADCChThreeHiAlarm 6 } aprisaXETxADCChThreeHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxADCChThreeHiAlarmName, aprisaXETxADCChThreeHiAlarmStatus, aprisaXETxADCChThreeHiAlarmSeverity, aprisaXETxADCChThreeHiAlarmEnabled, aprisaXETxADCChThreeHiAlarmThreshold, aprisaXETxADCChThreeHiAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXETx transmitter ADC Ch Three voltage too high alarm group." ::= { aprisaXEGroups 256 } aprisaXETxADCChThreeLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 30 } aprisaXETxADCChThreeLoAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the transmitter ADC Ch Three voltage too low alarm." ::= { aprisaXETxADCChThreeLoAlarm 1 } aprisaXETxADCChThreeLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter ADC Ch Three voltage too low alarm." ::= { aprisaXETxADCChThreeLoAlarm 2 } aprisaXETxADCChThreeLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the transmitter ADC Ch Three voltage too low alarm." ::= { aprisaXETxADCChThreeLoAlarm 3 } aprisaXETxADCChThreeLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the transmitter ADC Ch Three voltage too low alarm is enabled." ::= { aprisaXETxADCChThreeLoAlarm 4 } aprisaXETxADCChThreeLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Three voltage too low alarm will be set." ::= { aprisaXETxADCChThreeLoAlarm 5 } aprisaXETxADCChThreeLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Three voltage too low will be cleared." ::= { aprisaXETxADCChThreeLoAlarm 6 } aprisaXETxADCChThreeLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxADCChThreeLoAlarmName, aprisaXETxADCChThreeLoAlarmStatus, aprisaXETxADCChThreeLoAlarmSeverity, aprisaXETxADCChThreeLoAlarmEnabled, aprisaXETxADCChThreeLoAlarmThreshold, aprisaXETxADCChThreeLoAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXETx transmitter ADC Ch Three voltage too High alarm group." ::= { aprisaXEGroups 257 } aprisaXETxADCChFourHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 31 } aprisaXETxADCChFourHiAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the transmitter ADC Ch Four voltage too high alarm." ::= { aprisaXETxADCChFourHiAlarm 1 } aprisaXETxADCChFourHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter ADC Ch Four voltage too high alarm." ::= { aprisaXETxADCChFourHiAlarm 2 } aprisaXETxADCChFourHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the transmitter ADC Ch Four voltage too high alarm." ::= { aprisaXETxADCChFourHiAlarm 3 } aprisaXETxADCChFourHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the transmitter ADC Ch Four voltage too high alarm is enabled." ::= { aprisaXETxADCChFourHiAlarm 4 } aprisaXETxADCChFourHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the transmitter ADC Ch Four voltage too high alarm will be set." ::= { aprisaXETxADCChFourHiAlarm 5 } aprisaXETxADCChFourHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the transmitter ADC Ch Four voltage too high will be cleared." ::= { aprisaXETxADCChFourHiAlarm 6 } aprisaXETxADCChFourHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxADCChFourHiAlarmName, aprisaXETxADCChFourHiAlarmStatus, aprisaXETxADCChFourHiAlarmSeverity, aprisaXETxADCChFourHiAlarmEnabled, aprisaXETxADCChFourHiAlarmThreshold, aprisaXETxADCChFourHiAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXETx transmitter ADC Ch Four voltage too high alarm group." ::= { aprisaXEGroups 258 } aprisaXETxADCChFourLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 32 } aprisaXETxADCChFourLoAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the transmitter ADC Ch Four voltage too low alarm." ::= { aprisaXETxADCChFourLoAlarm 1 } aprisaXETxADCChFourLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter ADC Ch Four voltage too low alarm." ::= { aprisaXETxADCChFourLoAlarm 2 } aprisaXETxADCChFourLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the transmitter ADC Ch Four voltage too low alarm." ::= { aprisaXETxADCChFourLoAlarm 3 } aprisaXETxADCChFourLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the transmitter ADC Ch Four voltage too low alarm is enabled." ::= { aprisaXETxADCChFourLoAlarm 4 } aprisaXETxADCChFourLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Four voltage too low alarm will be set." ::= { aprisaXETxADCChFourLoAlarm 5 } aprisaXETxADCChFourLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Four voltage too low will be cleared." ::= { aprisaXETxADCChFourLoAlarm 6 } aprisaXETxADCChFourLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxADCChFourLoAlarmName, aprisaXETxADCChFourLoAlarmStatus, aprisaXETxADCChFourLoAlarmSeverity, aprisaXETxADCChFourLoAlarmEnabled, aprisaXETxADCChFourLoAlarmThreshold, aprisaXETxADCChFourLoAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXETx transmitter ADC Ch Four voltage too High alarm group." ::= { aprisaXEGroups 259 } aprisaXETxADCChFiveHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 33 } aprisaXETxADCChFiveHiAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the transmitter ADC Ch Five voltage too high alarm." ::= { aprisaXETxADCChFiveHiAlarm 1 } aprisaXETxADCChFiveHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter ADC Ch Five voltage too high alarm." ::= { aprisaXETxADCChFiveHiAlarm 2 } aprisaXETxADCChFiveHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the transmitter ADC Ch Five voltage too high alarm." ::= { aprisaXETxADCChFiveHiAlarm 3 } aprisaXETxADCChFiveHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the transmitter ADC Ch Five voltage too high alarm is enabled." ::= { aprisaXETxADCChFiveHiAlarm 4 } aprisaXETxADCChFiveHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the transmitter ADC Ch Five voltage too high alarm will be set." ::= { aprisaXETxADCChFiveHiAlarm 5 } aprisaXETxADCChFiveHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the transmitter ADC Ch Five voltage too high will be cleared." ::= { aprisaXETxADCChFiveHiAlarm 6 } aprisaXETxADCChFiveHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxADCChFiveHiAlarmName, aprisaXETxADCChFiveHiAlarmStatus, aprisaXETxADCChFiveHiAlarmSeverity, aprisaXETxADCChFiveHiAlarmEnabled, aprisaXETxADCChFiveHiAlarmThreshold, aprisaXETxADCChFiveHiAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXETx transmitter ADC Ch Five voltage too high alarm group." ::= { aprisaXEGroups 260 } aprisaXETxADCChFiveLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 34 } aprisaXETxADCChFiveLoAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the transmitter ADC Ch Five voltage too low alarm." ::= { aprisaXETxADCChFiveLoAlarm 1 } aprisaXETxADCChFiveLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter ADC Ch Five voltage too low alarm." ::= { aprisaXETxADCChFiveLoAlarm 2 } aprisaXETxADCChFiveLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the transmitter ADC Ch Five voltage too low alarm." ::= { aprisaXETxADCChFiveLoAlarm 3 } aprisaXETxADCChFiveLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the transmitter ADC Ch Five voltage too low alarm is enabled." ::= { aprisaXETxADCChFiveLoAlarm 4 } aprisaXETxADCChFiveLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Five voltage too low alarm will be set." ::= { aprisaXETxADCChFiveLoAlarm 5 } aprisaXETxADCChFiveLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Five voltage too low will be cleared." ::= { aprisaXETxADCChFiveLoAlarm 6 } aprisaXETxADCChFiveLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxADCChFiveLoAlarmName, aprisaXETxADCChFiveLoAlarmStatus, aprisaXETxADCChFiveLoAlarmSeverity, aprisaXETxADCChFiveLoAlarmEnabled, aprisaXETxADCChFiveLoAlarmThreshold, aprisaXETxADCChFiveLoAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXETx transmitter ADC Ch Five voltage too High alarm group." ::= { aprisaXEGroups 261 } aprisaXETxADCChSixHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 35 } aprisaXETxADCChSixHiAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the transmitter ADC Ch Six voltage too high alarm." ::= { aprisaXETxADCChSixHiAlarm 1 } aprisaXETxADCChSixHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter ADC Ch Six voltage too high alarm." ::= { aprisaXETxADCChSixHiAlarm 2 } aprisaXETxADCChSixHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the transmitter ADC Ch Six voltage too high alarm." ::= { aprisaXETxADCChSixHiAlarm 3 } aprisaXETxADCChSixHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the transmitter ADC Ch Six voltage too high alarm is enabled." ::= { aprisaXETxADCChSixHiAlarm 4 } aprisaXETxADCChSixHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the transmitter ADC Ch Six voltage too high alarm will be set." ::= { aprisaXETxADCChSixHiAlarm 5 } aprisaXETxADCChSixHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the transmitter ADC Ch Six voltage too high will be cleared." ::= { aprisaXETxADCChSixHiAlarm 6 } aprisaXETxADCChSixHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxADCChSixHiAlarmName, aprisaXETxADCChSixHiAlarmStatus, aprisaXETxADCChSixHiAlarmSeverity, aprisaXETxADCChSixHiAlarmEnabled, aprisaXETxADCChSixHiAlarmThreshold, aprisaXETxADCChSixHiAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXETx transmitter ADC Ch Six voltage too high alarm group." ::= { aprisaXEGroups 262 } aprisaXETxADCChSixLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 36 } aprisaXETxADCChSixLoAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the transmitter ADC Ch Six voltage too low alarm." ::= { aprisaXETxADCChSixLoAlarm 1 } aprisaXETxADCChSixLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter ADC Ch Six voltage too low alarm." ::= { aprisaXETxADCChSixLoAlarm 2 } aprisaXETxADCChSixLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the transmitter ADC Ch Six voltage too low alarm." ::= { aprisaXETxADCChSixLoAlarm 3 } aprisaXETxADCChSixLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the transmitter ADC Ch Six voltage too low alarm is enabled." ::= { aprisaXETxADCChSixLoAlarm 4 } aprisaXETxADCChSixLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Six voltage too low alarm will be set." ::= { aprisaXETxADCChSixLoAlarm 5 } aprisaXETxADCChSixLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Six voltage too low will be cleared." ::= { aprisaXETxADCChSixLoAlarm 6 } aprisaXETxADCChSixLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxADCChSixLoAlarmName, aprisaXETxADCChSixLoAlarmStatus, aprisaXETxADCChSixLoAlarmSeverity, aprisaXETxADCChSixLoAlarmEnabled, aprisaXETxADCChSixLoAlarmThreshold, aprisaXETxADCChSixLoAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXETx transmitter ADC Ch Six voltage too High alarm group." ::= { aprisaXEGroups 263 } aprisaXETxADCChSevenHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 37 } aprisaXETxADCChSevenHiAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the transmitter ADC Ch Seven voltage too high alarm." ::= { aprisaXETxADCChSevenHiAlarm 1 } aprisaXETxADCChSevenHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter ADC Ch Seven voltage too high alarm." ::= { aprisaXETxADCChSevenHiAlarm 2 } aprisaXETxADCChSevenHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the transmitter ADC Ch Seven voltage too high alarm." ::= { aprisaXETxADCChSevenHiAlarm 3 } aprisaXETxADCChSevenHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the transmitter ADC Ch Seven voltage too high alarm is enabled." ::= { aprisaXETxADCChSevenHiAlarm 4 } aprisaXETxADCChSevenHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the transmitter ADC Ch Seven voltage too high alarm will be set." ::= { aprisaXETxADCChSevenHiAlarm 5 } aprisaXETxADCChSevenHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the transmitter ADC Ch Seven voltage too high will be cleared." ::= { aprisaXETxADCChSevenHiAlarm 6 } aprisaXETxADCChSevenHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxADCChSevenHiAlarmName, aprisaXETxADCChSevenHiAlarmStatus, aprisaXETxADCChSevenHiAlarmSeverity, aprisaXETxADCChSevenHiAlarmEnabled, aprisaXETxADCChSevenHiAlarmThreshold, aprisaXETxADCChSevenHiAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXETx transmitter ADC Ch Seven voltage too high alarm group." ::= { aprisaXEGroups 264 } aprisaXETxADCChSevenLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 38 } aprisaXETxADCChSevenLoAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the transmitter ADC Ch Seven voltage too low alarm." ::= { aprisaXETxADCChSevenLoAlarm 1 } aprisaXETxADCChSevenLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter ADC Ch Seven voltage too low alarm." ::= { aprisaXETxADCChSevenLoAlarm 2 } aprisaXETxADCChSevenLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the transmitter ADC Ch Seven voltage too low alarm." ::= { aprisaXETxADCChSevenLoAlarm 3 } aprisaXETxADCChSevenLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the transmitter ADC Ch Seven voltage too low alarm is enabled." ::= { aprisaXETxADCChSevenLoAlarm 4 } aprisaXETxADCChSevenLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Seven voltage too low alarm will be set." ::= { aprisaXETxADCChSevenLoAlarm 5 } aprisaXETxADCChSevenLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Seven voltage too low will be cleared." ::= { aprisaXETxADCChSevenLoAlarm 6 } aprisaXETxADCChSevenLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxADCChSevenLoAlarmName, aprisaXETxADCChSevenLoAlarmStatus, aprisaXETxADCChSevenLoAlarmSeverity, aprisaXETxADCChSevenLoAlarmEnabled, aprisaXETxADCChSevenLoAlarmThreshold, aprisaXETxADCChSevenLoAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXETx transmitter ADC Ch Seven voltage too High alarm group." ::= { aprisaXEGroups 265 } aprisaXETxADCChEightHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 39 } aprisaXETxADCChEightHiAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the transmitter ADC Ch Eight voltage too high alarm." ::= { aprisaXETxADCChEightHiAlarm 1 } aprisaXETxADCChEightHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter ADC Ch Eight voltage too high alarm." ::= { aprisaXETxADCChEightHiAlarm 2 } aprisaXETxADCChEightHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the transmitter ADC Ch Eight voltage too high alarm." ::= { aprisaXETxADCChEightHiAlarm 3 } aprisaXETxADCChEightHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the transmitter ADC Ch Eight voltage too high alarm is enabled." ::= { aprisaXETxADCChEightHiAlarm 4 } aprisaXETxADCChEightHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the transmitter ADC Ch Eight voltage too high alarm will be set." ::= { aprisaXETxADCChEightHiAlarm 5 } aprisaXETxADCChEightHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the transmitter ADC Ch Eight voltage too high will be cleared." ::= { aprisaXETxADCChEightHiAlarm 6 } aprisaXETxADCChEightHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxADCChEightHiAlarmName, aprisaXETxADCChEightHiAlarmStatus, aprisaXETxADCChEightHiAlarmSeverity, aprisaXETxADCChEightHiAlarmEnabled, aprisaXETxADCChEightHiAlarmThreshold, aprisaXETxADCChEightHiAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXETx transmitter ADC Ch Eight voltage too high alarm group." ::= { aprisaXEGroups 266 } aprisaXETxADCChEightLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 40 } aprisaXETxADCChEightLoAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the transmitter ADC Ch Eight voltage too low alarm." ::= { aprisaXETxADCChEightLoAlarm 1 } aprisaXETxADCChEightLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter ADC Ch Eight voltage too low alarm." ::= { aprisaXETxADCChEightLoAlarm 2 } aprisaXETxADCChEightLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the transmitter ADC Ch Eight voltage too low alarm." ::= { aprisaXETxADCChEightLoAlarm 3 } aprisaXETxADCChEightLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the transmitter ADC Ch Eight voltage too low alarm is enabled." ::= { aprisaXETxADCChEightLoAlarm 4 } aprisaXETxADCChEightLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Eight voltage too low alarm will be set." ::= { aprisaXETxADCChEightLoAlarm 5 } aprisaXETxADCChEightLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Eight voltage too low will be cleared." ::= { aprisaXETxADCChEightLoAlarm 6 } aprisaXETxADCChEightLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxADCChEightLoAlarmName, aprisaXETxADCChEightLoAlarmStatus, aprisaXETxADCChEightLoAlarmSeverity, aprisaXETxADCChEightLoAlarmEnabled, aprisaXETxADCChEightLoAlarmThreshold, aprisaXETxADCChEightLoAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXETx transmitter ADC Ch Eight voltage too High alarm group." ::= { aprisaXEGroups 267 } aprisaXETxADCChNineHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 41 } aprisaXETxADCChNineHiAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the transmitter ADC Ch Nine voltage too high alarm." ::= { aprisaXETxADCChNineHiAlarm 1 } aprisaXETxADCChNineHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter ADC Ch Nine voltage too high alarm." ::= { aprisaXETxADCChNineHiAlarm 2 } aprisaXETxADCChNineHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the transmitter ADC Ch Nine voltage too high alarm." ::= { aprisaXETxADCChNineHiAlarm 3 } aprisaXETxADCChNineHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the transmitter ADC Ch Nine voltage too high alarm is enabled." ::= { aprisaXETxADCChNineHiAlarm 4 } aprisaXETxADCChNineHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the transmitter ADC Ch Nine voltage too high alarm will be set." ::= { aprisaXETxADCChNineHiAlarm 5 } aprisaXETxADCChNineHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the transmitter ADC Ch Nine voltage too high will be cleared." ::= { aprisaXETxADCChNineHiAlarm 6 } aprisaXETxADCChNineHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxADCChNineHiAlarmName, aprisaXETxADCChNineHiAlarmStatus, aprisaXETxADCChNineHiAlarmSeverity, aprisaXETxADCChNineHiAlarmEnabled, aprisaXETxADCChNineHiAlarmThreshold, aprisaXETxADCChNineHiAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXETx transmitter ADC Ch Nine voltage too high alarm group." ::= { aprisaXEGroups 268 } aprisaXETxADCChNineLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 42 } aprisaXETxADCChNineLoAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the transmitter ADC Ch Nine voltage too low alarm." ::= { aprisaXETxADCChNineLoAlarm 1 } aprisaXETxADCChNineLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter ADC Ch Nine voltage too low alarm." ::= { aprisaXETxADCChNineLoAlarm 2 } aprisaXETxADCChNineLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the transmitter ADC Ch Nine voltage too low alarm." ::= { aprisaXETxADCChNineLoAlarm 3 } aprisaXETxADCChNineLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the transmitter ADC Ch Nine voltage too low alarm is enabled." ::= { aprisaXETxADCChNineLoAlarm 4 } aprisaXETxADCChNineLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Nine voltage too low alarm will be set." ::= { aprisaXETxADCChNineLoAlarm 5 } aprisaXETxADCChNineLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Nine voltage too low will be cleared." ::= { aprisaXETxADCChNineLoAlarm 6 } aprisaXETxADCChNineLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxADCChNineLoAlarmName, aprisaXETxADCChNineLoAlarmStatus, aprisaXETxADCChNineLoAlarmSeverity, aprisaXETxADCChNineLoAlarmEnabled, aprisaXETxADCChNineLoAlarmThreshold, aprisaXETxADCChNineLoAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXETx transmitter ADC Ch Nine voltage too High alarm group." ::= { aprisaXEGroups 269 } aprisaXETxADCChTenHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 43 } aprisaXETxADCChTenHiAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the transmitter ADC Ch Ten voltage too high alarm." ::= { aprisaXETxADCChTenHiAlarm 1 } aprisaXETxADCChTenHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter ADC Ch Ten voltage too high alarm." ::= { aprisaXETxADCChTenHiAlarm 2 } aprisaXETxADCChTenHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the transmitter ADC Ch Ten voltage too high alarm." ::= { aprisaXETxADCChTenHiAlarm 3 } aprisaXETxADCChTenHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the transmitter ADC Ch Ten voltage too high alarm is enabled." ::= { aprisaXETxADCChTenHiAlarm 4 } aprisaXETxADCChTenHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the transmitter ADC Ch Ten voltage too high alarm will be set." ::= { aprisaXETxADCChTenHiAlarm 5 } aprisaXETxADCChTenHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the transmitter ADC Ch Ten voltage too high will be cleared." ::= { aprisaXETxADCChTenHiAlarm 6 } aprisaXETxADCChTenHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxADCChTenHiAlarmName, aprisaXETxADCChTenHiAlarmStatus, aprisaXETxADCChTenHiAlarmSeverity, aprisaXETxADCChTenHiAlarmEnabled, aprisaXETxADCChTenHiAlarmThreshold, aprisaXETxADCChTenHiAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXETx transmitter ADC Ch Ten voltage too high alarm group." ::= { aprisaXEGroups 270 } aprisaXETxADCChTenLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 44 } aprisaXETxADCChTenLoAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the transmitter ADC Ch Ten voltage too low alarm." ::= { aprisaXETxADCChTenLoAlarm 1 } aprisaXETxADCChTenLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter ADC Ch Ten voltage too low alarm." ::= { aprisaXETxADCChTenLoAlarm 2 } aprisaXETxADCChTenLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the transmitter ADC Ch Ten voltage too low alarm." ::= { aprisaXETxADCChTenLoAlarm 3 } aprisaXETxADCChTenLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the transmitter ADC Ch Ten voltage too low alarm is enabled." ::= { aprisaXETxADCChTenLoAlarm 4 } aprisaXETxADCChTenLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Ten voltage too low alarm will be set." ::= { aprisaXETxADCChTenLoAlarm 5 } aprisaXETxADCChTenLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Ten voltage too low will be cleared." ::= { aprisaXETxADCChTenLoAlarm 6 } aprisaXETxADCChTenLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxADCChTenLoAlarmName, aprisaXETxADCChTenLoAlarmStatus, aprisaXETxADCChTenLoAlarmSeverity, aprisaXETxADCChTenLoAlarmEnabled, aprisaXETxADCChTenLoAlarmThreshold, aprisaXETxADCChTenLoAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXETx transmitter ADC Ch Ten voltage too High alarm group." ::= { aprisaXEGroups 271 } aprisaXETxADCChElevenHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 45 } aprisaXETxADCChElevenHiAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the transmitter ADC Ch Eleven voltage too high alarm." ::= { aprisaXETxADCChElevenHiAlarm 1 } aprisaXETxADCChElevenHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter ADC Ch Eleven voltage too high alarm." ::= { aprisaXETxADCChElevenHiAlarm 2 } aprisaXETxADCChElevenHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the transmitter ADC Ch Eleven voltage too high alarm." ::= { aprisaXETxADCChElevenHiAlarm 3 } aprisaXETxADCChElevenHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the transmitter ADC Ch Eleven voltage too high alarm is enabled." ::= { aprisaXETxADCChElevenHiAlarm 4 } aprisaXETxADCChElevenHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the transmitter ADC Ch Eleven voltage too high alarm will be set." ::= { aprisaXETxADCChElevenHiAlarm 5 } aprisaXETxADCChElevenHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the transmitter ADC Ch Eleven voltage too high will be cleared." ::= { aprisaXETxADCChElevenHiAlarm 6 } aprisaXETxADCChElevenHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxADCChElevenHiAlarmName, aprisaXETxADCChElevenHiAlarmStatus, aprisaXETxADCChElevenHiAlarmSeverity, aprisaXETxADCChElevenHiAlarmEnabled, aprisaXETxADCChElevenHiAlarmThreshold, aprisaXETxADCChElevenHiAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXETx transmitter ADC Ch Eleven voltage too high alarm group." ::= { aprisaXEGroups 272 } aprisaXETxADCChElevenLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 46 } aprisaXETxADCChElevenLoAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the transmitter ADC Ch Eleven voltage too low alarm." ::= { aprisaXETxADCChElevenLoAlarm 1 } aprisaXETxADCChElevenLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the transmitter ADC Ch Eleven voltage too low alarm." ::= { aprisaXETxADCChElevenLoAlarm 2 } aprisaXETxADCChElevenLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the transmitter ADC Ch Eleven voltage too low alarm." ::= { aprisaXETxADCChElevenLoAlarm 3 } aprisaXETxADCChElevenLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the transmitter ADC Ch Eleven voltage too low alarm is enabled." ::= { aprisaXETxADCChElevenLoAlarm 4 } aprisaXETxADCChElevenLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Eleven voltage too low alarm will be set." ::= { aprisaXETxADCChElevenLoAlarm 5 } aprisaXETxADCChElevenLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Eleven voltage too low will be cleared." ::= { aprisaXETxADCChElevenLoAlarm 6 } aprisaXETxADCChElevenLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXETxADCChElevenLoAlarmName, aprisaXETxADCChElevenLoAlarmStatus, aprisaXETxADCChElevenLoAlarmSeverity, aprisaXETxADCChElevenLoAlarmEnabled, aprisaXETxADCChElevenLoAlarmThreshold, aprisaXETxADCChElevenLoAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXETx transmitter ADC Ch Eleven voltage too High alarm group." ::= { aprisaXEGroups 273 } -- *************************************************************************** -- End of the Generic Transmitter alarms -- *************************************************************************** -- *************************************************************************** -- The Generic Receiver Alarms -- *************************************************************************** aprisaXERxADCChZeroHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 19 } aprisaXERxADCChZeroHiAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the receiver ADC Ch Zero voltage too high alarm." ::= { aprisaXERxADCChZeroHiAlarm 1 } aprisaXERxADCChZeroHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the receiver ADC Ch Zero voltage too high alarm." ::= { aprisaXERxADCChZeroHiAlarm 2 } aprisaXERxADCChZeroHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the receiver ADC Ch Zero voltage too high alarm." ::= { aprisaXERxADCChZeroHiAlarm 3 } aprisaXERxADCChZeroHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the receiver ADC Ch Zero voltage too high alarm is enabled." ::= { aprisaXERxADCChZeroHiAlarm 4 } aprisaXERxADCChZeroHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the receiver ADC Ch Zero voltage too high alarm will be set." ::= { aprisaXERxADCChZeroHiAlarm 5 } aprisaXERxADCChZeroHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the receiver ADC Ch Zero voltage too high will be cleared." ::= { aprisaXERxADCChZeroHiAlarm 6 } aprisaXERxADCChZeroHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxADCChZeroHiAlarmName, aprisaXERxADCChZeroHiAlarmStatus, aprisaXERxADCChZeroHiAlarmSeverity, aprisaXERxADCChZeroHiAlarmEnabled, aprisaXERxADCChZeroHiAlarmThreshold, aprisaXERxADCChZeroHiAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXERx receiver ADC Ch Zero voltage too high alarm group." ::= { aprisaXEGroups 275 } aprisaXERxADCChZeroLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 20 } aprisaXERxADCChZeroLoAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the receiver ADC Ch Zero voltage too low alarm." ::= { aprisaXERxADCChZeroLoAlarm 1 } aprisaXERxADCChZeroLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the receiver ADC Ch Zero voltage too low alarm." ::= { aprisaXERxADCChZeroLoAlarm 2 } aprisaXERxADCChZeroLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the receiver ADC Ch Zero voltage too low alarm." ::= { aprisaXERxADCChZeroLoAlarm 3 } aprisaXERxADCChZeroLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the receiver ADC Ch Zero voltage too low alarm is enabled." ::= { aprisaXERxADCChZeroLoAlarm 4 } aprisaXERxADCChZeroLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Zero voltage too low alarm will be set." ::= { aprisaXERxADCChZeroLoAlarm 5 } aprisaXERxADCChZeroLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Zero voltage too low will be cleared." ::= { aprisaXERxADCChZeroLoAlarm 6 } aprisaXERxADCChZeroLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxADCChZeroLoAlarmName, aprisaXERxADCChZeroLoAlarmStatus, aprisaXERxADCChZeroLoAlarmSeverity, aprisaXERxADCChZeroLoAlarmEnabled, aprisaXERxADCChZeroLoAlarmThreshold, aprisaXERxADCChZeroLoAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXERx receiver ADC Ch Zero voltage too High alarm group." ::= { aprisaXEGroups 276 } aprisaXERxADCChOneHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 21 } aprisaXERxADCChOneHiAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the receiver ADC Ch One voltage too high alarm." ::= { aprisaXERxADCChOneHiAlarm 1 } aprisaXERxADCChOneHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the receiver ADC Ch One voltage too high alarm." ::= { aprisaXERxADCChOneHiAlarm 2 } aprisaXERxADCChOneHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the receiver ADC Ch One voltage too high alarm." ::= { aprisaXERxADCChOneHiAlarm 3 } aprisaXERxADCChOneHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the receiver ADC Ch One voltage too high alarm is enabled." ::= { aprisaXERxADCChOneHiAlarm 4 } aprisaXERxADCChOneHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the receiver ADC Ch One voltage too high alarm will be set." ::= { aprisaXERxADCChOneHiAlarm 5 } aprisaXERxADCChOneHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the receiver ADC Ch One voltage too high will be cleared." ::= { aprisaXERxADCChOneHiAlarm 6 } aprisaXERxADCChOneHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxADCChOneHiAlarmName, aprisaXERxADCChOneHiAlarmStatus, aprisaXERxADCChOneHiAlarmSeverity, aprisaXERxADCChOneHiAlarmEnabled, aprisaXERxADCChOneHiAlarmThreshold, aprisaXERxADCChOneHiAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXERx receiver ADC Ch One voltage too high alarm group." ::= { aprisaXEGroups 277 } aprisaXERxADCChOneLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 22 } aprisaXERxADCChOneLoAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the receiver ADC Ch One voltage too low alarm." ::= { aprisaXERxADCChOneLoAlarm 1 } aprisaXERxADCChOneLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the receiver ADC Ch One voltage too low alarm." ::= { aprisaXERxADCChOneLoAlarm 2 } aprisaXERxADCChOneLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the receiver ADC Ch One voltage too low alarm." ::= { aprisaXERxADCChOneLoAlarm 3 } aprisaXERxADCChOneLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the receiver ADC Ch One voltage too low alarm is enabled." ::= { aprisaXERxADCChOneLoAlarm 4 } aprisaXERxADCChOneLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch One voltage too low alarm will be set." ::= { aprisaXERxADCChOneLoAlarm 5 } aprisaXERxADCChOneLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch One voltage too low will be cleared." ::= { aprisaXERxADCChOneLoAlarm 6 } aprisaXERxADCChOneLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxADCChOneLoAlarmName, aprisaXERxADCChOneLoAlarmStatus, aprisaXERxADCChOneLoAlarmSeverity, aprisaXERxADCChOneLoAlarmEnabled, aprisaXERxADCChOneLoAlarmThreshold, aprisaXERxADCChOneLoAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXERx receiver ADC Ch One voltage too High alarm group." ::= { aprisaXEGroups 278 } aprisaXERxADCChTwoHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 23 } aprisaXERxADCChTwoHiAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the receiver ADC Ch Two voltage too high alarm." ::= { aprisaXERxADCChTwoHiAlarm 1 } aprisaXERxADCChTwoHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the receiver ADC Ch Two voltage too high alarm." ::= { aprisaXERxADCChTwoHiAlarm 2 } aprisaXERxADCChTwoHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the receiver ADC Ch Two voltage too high alarm." ::= { aprisaXERxADCChTwoHiAlarm 3 } aprisaXERxADCChTwoHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the receiver ADC Ch Two voltage too high alarm is enabled." ::= { aprisaXERxADCChTwoHiAlarm 4 } aprisaXERxADCChTwoHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the receiver ADC Ch Two voltage too high alarm will be set." ::= { aprisaXERxADCChTwoHiAlarm 5 } aprisaXERxADCChTwoHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the receiver ADC Ch Two voltage too high will be cleared." ::= { aprisaXERxADCChTwoHiAlarm 6 } aprisaXERxADCChTwoHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxADCChTwoHiAlarmName, aprisaXERxADCChTwoHiAlarmStatus, aprisaXERxADCChTwoHiAlarmSeverity, aprisaXERxADCChTwoHiAlarmEnabled, aprisaXERxADCChTwoHiAlarmThreshold, aprisaXERxADCChTwoHiAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXERx receiver ADC Ch Two voltage too high alarm group." ::= { aprisaXEGroups 279 } aprisaXERxADCChTwoLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 24 } aprisaXERxADCChTwoLoAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the receiver ADC Ch Two voltage too low alarm." ::= { aprisaXERxADCChTwoLoAlarm 1 } aprisaXERxADCChTwoLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the receiver ADC Ch Two voltage too low alarm." ::= { aprisaXERxADCChTwoLoAlarm 2 } aprisaXERxADCChTwoLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the receiver ADC Ch Two voltage too low alarm." ::= { aprisaXERxADCChTwoLoAlarm 3 } aprisaXERxADCChTwoLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the receiver ADC Ch Two voltage too low alarm is enabled." ::= { aprisaXERxADCChTwoLoAlarm 4 } aprisaXERxADCChTwoLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Two voltage too low alarm will be set." ::= { aprisaXERxADCChTwoLoAlarm 5 } aprisaXERxADCChTwoLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Two voltage too low will be cleared." ::= { aprisaXERxADCChTwoLoAlarm 6 } aprisaXERxADCChTwoLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxADCChTwoLoAlarmName, aprisaXERxADCChTwoLoAlarmStatus, aprisaXERxADCChTwoLoAlarmSeverity, aprisaXERxADCChTwoLoAlarmEnabled, aprisaXERxADCChTwoLoAlarmThreshold, aprisaXERxADCChTwoLoAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXERx receiver ADC Ch Two voltage too High alarm group." ::= { aprisaXEGroups 280 } aprisaXERxADCChThreeHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 25 } aprisaXERxADCChThreeHiAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the receiver ADC Ch Three voltage too high alarm." ::= { aprisaXERxADCChThreeHiAlarm 1 } aprisaXERxADCChThreeHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the receiver ADC Ch Three voltage too high alarm." ::= { aprisaXERxADCChThreeHiAlarm 2 } aprisaXERxADCChThreeHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the receiver ADC Ch Three voltage too high alarm." ::= { aprisaXERxADCChThreeHiAlarm 3 } aprisaXERxADCChThreeHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the receiver ADC Ch Three voltage too high alarm is enabled." ::= { aprisaXERxADCChThreeHiAlarm 4 } aprisaXERxADCChThreeHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the receiver ADC Ch Three voltage too high alarm will be set." ::= { aprisaXERxADCChThreeHiAlarm 5 } aprisaXERxADCChThreeHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the receiver ADC Ch Three voltage too high will be cleared." ::= { aprisaXERxADCChThreeHiAlarm 6 } aprisaXERxADCChThreeHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxADCChThreeHiAlarmName, aprisaXERxADCChThreeHiAlarmStatus, aprisaXERxADCChThreeHiAlarmSeverity, aprisaXERxADCChThreeHiAlarmEnabled, aprisaXERxADCChThreeHiAlarmThreshold, aprisaXERxADCChThreeHiAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXERx receiver ADC Ch Three voltage too high alarm group." ::= { aprisaXEGroups 281 } aprisaXERxADCChThreeLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 26 } aprisaXERxADCChThreeLoAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the receiver ADC Ch Three voltage too low alarm." ::= { aprisaXERxADCChThreeLoAlarm 1 } aprisaXERxADCChThreeLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the receiver ADC Ch Three voltage too low alarm." ::= { aprisaXERxADCChThreeLoAlarm 2 } aprisaXERxADCChThreeLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the receiver ADC Ch Three voltage too low alarm." ::= { aprisaXERxADCChThreeLoAlarm 3 } aprisaXERxADCChThreeLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the receiver ADC Ch Three voltage too low alarm is enabled." ::= { aprisaXERxADCChThreeLoAlarm 4 } aprisaXERxADCChThreeLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Three voltage too low alarm will be set." ::= { aprisaXERxADCChThreeLoAlarm 5 } aprisaXERxADCChThreeLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Three voltage too low will be cleared." ::= { aprisaXERxADCChThreeLoAlarm 6 } aprisaXERxADCChThreeLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxADCChThreeLoAlarmName, aprisaXERxADCChThreeLoAlarmStatus, aprisaXERxADCChThreeLoAlarmSeverity, aprisaXERxADCChThreeLoAlarmEnabled, aprisaXERxADCChThreeLoAlarmThreshold, aprisaXERxADCChThreeLoAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXERx receiver ADC Ch Three voltage too High alarm group." ::= { aprisaXEGroups 282 } aprisaXERxADCChFourHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 27 } aprisaXERxADCChFourHiAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the receiver ADC Ch Four voltage too high alarm." ::= { aprisaXERxADCChFourHiAlarm 1 } aprisaXERxADCChFourHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the receiver ADC Ch Four voltage too high alarm." ::= { aprisaXERxADCChFourHiAlarm 2 } aprisaXERxADCChFourHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the receiver ADC Ch Four voltage too high alarm." ::= { aprisaXERxADCChFourHiAlarm 3 } aprisaXERxADCChFourHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the receiver ADC Ch Four voltage too high alarm is enabled." ::= { aprisaXERxADCChFourHiAlarm 4 } aprisaXERxADCChFourHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the receiver ADC Ch Four voltage too high alarm will be set." ::= { aprisaXERxADCChFourHiAlarm 5 } aprisaXERxADCChFourHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the receiver ADC Ch Four voltage too high will be cleared." ::= { aprisaXERxADCChFourHiAlarm 6 } aprisaXERxADCChFourHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxADCChFourHiAlarmName, aprisaXERxADCChFourHiAlarmStatus, aprisaXERxADCChFourHiAlarmSeverity, aprisaXERxADCChFourHiAlarmEnabled, aprisaXERxADCChFourHiAlarmThreshold, aprisaXERxADCChFourHiAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXERx receiver ADC Ch Four voltage too high alarm group." ::= { aprisaXEGroups 283 } aprisaXERxADCChFourLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 28 } aprisaXERxADCChFourLoAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the receiver ADC Ch Four voltage too low alarm." ::= { aprisaXERxADCChFourLoAlarm 1 } aprisaXERxADCChFourLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the receiver ADC Ch Four voltage too low alarm." ::= { aprisaXERxADCChFourLoAlarm 2 } aprisaXERxADCChFourLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the receiver ADC Ch Four voltage too low alarm." ::= { aprisaXERxADCChFourLoAlarm 3 } aprisaXERxADCChFourLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the receiver ADC Ch Four voltage too low alarm is enabled." ::= { aprisaXERxADCChFourLoAlarm 4 } aprisaXERxADCChFourLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Four voltage too low alarm will be set." ::= { aprisaXERxADCChFourLoAlarm 5 } aprisaXERxADCChFourLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Four voltage too low will be cleared." ::= { aprisaXERxADCChFourLoAlarm 6 } aprisaXERxADCChFourLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxADCChFourLoAlarmName, aprisaXERxADCChFourLoAlarmStatus, aprisaXERxADCChFourLoAlarmSeverity, aprisaXERxADCChFourLoAlarmEnabled, aprisaXERxADCChFourLoAlarmThreshold, aprisaXERxADCChFourLoAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXERx receiver ADC Ch Four voltage too High alarm group." ::= { aprisaXEGroups 284 } aprisaXERxADCChFiveHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 29 } aprisaXERxADCChFiveHiAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the receiver ADC Ch Five voltage too high alarm." ::= { aprisaXERxADCChFiveHiAlarm 1 } aprisaXERxADCChFiveHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the receiver ADC Ch Five voltage too high alarm." ::= { aprisaXERxADCChFiveHiAlarm 2 } aprisaXERxADCChFiveHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the receiver ADC Ch Five voltage too high alarm." ::= { aprisaXERxADCChFiveHiAlarm 3 } aprisaXERxADCChFiveHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the receiver ADC Ch Five voltage too high alarm is enabled." ::= { aprisaXERxADCChFiveHiAlarm 4 } aprisaXERxADCChFiveHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the receiver ADC Ch Five voltage too high alarm will be set." ::= { aprisaXERxADCChFiveHiAlarm 5 } aprisaXERxADCChFiveHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the receiver ADC Ch Five voltage too high will be cleared." ::= { aprisaXERxADCChFiveHiAlarm 6 } aprisaXERxADCChFiveHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxADCChFiveHiAlarmName, aprisaXERxADCChFiveHiAlarmStatus, aprisaXERxADCChFiveHiAlarmSeverity, aprisaXERxADCChFiveHiAlarmEnabled, aprisaXERxADCChFiveHiAlarmThreshold, aprisaXERxADCChFiveHiAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXERx receiver ADC Ch Five voltage too high alarm group." ::= { aprisaXEGroups 285 } aprisaXERxADCChFiveLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 30 } aprisaXERxADCChFiveLoAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the receiver ADC Ch Five voltage too low alarm." ::= { aprisaXERxADCChFiveLoAlarm 1 } aprisaXERxADCChFiveLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the receiver ADC Ch Five voltage too low alarm." ::= { aprisaXERxADCChFiveLoAlarm 2 } aprisaXERxADCChFiveLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the receiver ADC Ch Five voltage too low alarm." ::= { aprisaXERxADCChFiveLoAlarm 3 } aprisaXERxADCChFiveLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the receiver ADC Ch Five voltage too low alarm is enabled." ::= { aprisaXERxADCChFiveLoAlarm 4 } aprisaXERxADCChFiveLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Five voltage too low alarm will be set." ::= { aprisaXERxADCChFiveLoAlarm 5 } aprisaXERxADCChFiveLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Five voltage too low will be cleared." ::= { aprisaXERxADCChFiveLoAlarm 6 } aprisaXERxADCChFiveLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxADCChFiveLoAlarmName, aprisaXERxADCChFiveLoAlarmStatus, aprisaXERxADCChFiveLoAlarmSeverity, aprisaXERxADCChFiveLoAlarmEnabled, aprisaXERxADCChFiveLoAlarmThreshold, aprisaXERxADCChFiveLoAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXERx receiver ADC Ch Five voltage too High alarm group." ::= { aprisaXEGroups 286 } aprisaXERxADCChSixHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 31 } aprisaXERxADCChSixHiAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the receiver ADC Ch Six voltage too high alarm." ::= { aprisaXERxADCChSixHiAlarm 1 } aprisaXERxADCChSixHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the receiver ADC Ch Six voltage too high alarm." ::= { aprisaXERxADCChSixHiAlarm 2 } aprisaXERxADCChSixHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the receiver ADC Ch Six voltage too high alarm." ::= { aprisaXERxADCChSixHiAlarm 3 } aprisaXERxADCChSixHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the receiver ADC Ch Six voltage too high alarm is enabled." ::= { aprisaXERxADCChSixHiAlarm 4 } aprisaXERxADCChSixHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the receiver ADC Ch Six voltage too high alarm will be set." ::= { aprisaXERxADCChSixHiAlarm 5 } aprisaXERxADCChSixHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the receiver ADC Ch Six voltage too high will be cleared." ::= { aprisaXERxADCChSixHiAlarm 6 } aprisaXERxADCChSixHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxADCChSixHiAlarmName, aprisaXERxADCChSixHiAlarmStatus, aprisaXERxADCChSixHiAlarmSeverity, aprisaXERxADCChSixHiAlarmEnabled, aprisaXERxADCChSixHiAlarmThreshold, aprisaXERxADCChSixHiAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXERx receiver ADC Ch Six voltage too high alarm group." ::= { aprisaXEGroups 287 } aprisaXERxADCChSixLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 32 } aprisaXERxADCChSixLoAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the receiver ADC Ch Six voltage too low alarm." ::= { aprisaXERxADCChSixLoAlarm 1 } aprisaXERxADCChSixLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the receiver ADC Ch Six voltage too low alarm." ::= { aprisaXERxADCChSixLoAlarm 2 } aprisaXERxADCChSixLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the receiver ADC Ch Six voltage too low alarm." ::= { aprisaXERxADCChSixLoAlarm 3 } aprisaXERxADCChSixLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the receiver ADC Ch Six voltage too low alarm is enabled." ::= { aprisaXERxADCChSixLoAlarm 4 } aprisaXERxADCChSixLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Six voltage too low alarm will be set." ::= { aprisaXERxADCChSixLoAlarm 5 } aprisaXERxADCChSixLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Six voltage too low will be cleared." ::= { aprisaXERxADCChSixLoAlarm 6 } aprisaXERxADCChSixLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxADCChSixLoAlarmName, aprisaXERxADCChSixLoAlarmStatus, aprisaXERxADCChSixLoAlarmSeverity, aprisaXERxADCChSixLoAlarmEnabled, aprisaXERxADCChSixLoAlarmThreshold, aprisaXERxADCChSixLoAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXERx receiver ADC Ch Six voltage too High alarm group." ::= { aprisaXEGroups 288 } aprisaXERxADCChSevenHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 33 } aprisaXERxADCChSevenHiAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the receiver ADC Ch Seven voltage too high alarm." ::= { aprisaXERxADCChSevenHiAlarm 1 } aprisaXERxADCChSevenHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the receiver ADC Ch Seven voltage too high alarm." ::= { aprisaXERxADCChSevenHiAlarm 2 } aprisaXERxADCChSevenHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the receiver ADC Ch Seven voltage too high alarm." ::= { aprisaXERxADCChSevenHiAlarm 3 } aprisaXERxADCChSevenHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the receiver ADC Ch Seven voltage too high alarm is enabled." ::= { aprisaXERxADCChSevenHiAlarm 4 } aprisaXERxADCChSevenHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the receiver ADC Ch Seven voltage too high alarm will be set." ::= { aprisaXERxADCChSevenHiAlarm 5 } aprisaXERxADCChSevenHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the receiver ADC Ch Seven voltage too high will be cleared." ::= { aprisaXERxADCChSevenHiAlarm 6 } aprisaXERxADCChSevenHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxADCChSevenHiAlarmName, aprisaXERxADCChSevenHiAlarmStatus, aprisaXERxADCChSevenHiAlarmSeverity, aprisaXERxADCChSevenHiAlarmEnabled, aprisaXERxADCChSevenHiAlarmThreshold, aprisaXERxADCChSevenHiAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXERx receiver ADC Ch Seven voltage too high alarm group." ::= { aprisaXEGroups 289 } aprisaXERxADCChSevenLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 34 } aprisaXERxADCChSevenLoAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the receiver ADC Ch Seven voltage too low alarm." ::= { aprisaXERxADCChSevenLoAlarm 1 } aprisaXERxADCChSevenLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the receiver ADC Ch Seven voltage too low alarm." ::= { aprisaXERxADCChSevenLoAlarm 2 } aprisaXERxADCChSevenLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the receiver ADC Ch Seven voltage too low alarm." ::= { aprisaXERxADCChSevenLoAlarm 3 } aprisaXERxADCChSevenLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the receiver ADC Ch Seven voltage too low alarm is enabled." ::= { aprisaXERxADCChSevenLoAlarm 4 } aprisaXERxADCChSevenLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Seven voltage too low alarm will be set." ::= { aprisaXERxADCChSevenLoAlarm 5 } aprisaXERxADCChSevenLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Seven voltage too low will be cleared." ::= { aprisaXERxADCChSevenLoAlarm 6 } aprisaXERxADCChSevenLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxADCChSevenLoAlarmName, aprisaXERxADCChSevenLoAlarmStatus, aprisaXERxADCChSevenLoAlarmSeverity, aprisaXERxADCChSevenLoAlarmEnabled, aprisaXERxADCChSevenLoAlarmThreshold, aprisaXERxADCChSevenLoAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXERx receiver ADC Ch Seven voltage too High alarm group." ::= { aprisaXEGroups 290 } aprisaXERxADCChEightHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 35 } aprisaXERxADCChEightHiAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the receiver ADC Ch Eight voltage too high alarm." ::= { aprisaXERxADCChEightHiAlarm 1 } aprisaXERxADCChEightHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the receiver ADC Ch Eight voltage too high alarm." ::= { aprisaXERxADCChEightHiAlarm 2 } aprisaXERxADCChEightHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the receiver ADC Ch Eight voltage too high alarm." ::= { aprisaXERxADCChEightHiAlarm 3 } aprisaXERxADCChEightHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the receiver ADC Ch Eight voltage too high alarm is enabled." ::= { aprisaXERxADCChEightHiAlarm 4 } aprisaXERxADCChEightHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the receiver ADC Ch Eight voltage too high alarm will be set." ::= { aprisaXERxADCChEightHiAlarm 5 } aprisaXERxADCChEightHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the receiver ADC Ch Eight voltage too high will be cleared." ::= { aprisaXERxADCChEightHiAlarm 6 } aprisaXERxADCChEightHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxADCChEightHiAlarmName, aprisaXERxADCChEightHiAlarmStatus, aprisaXERxADCChEightHiAlarmSeverity, aprisaXERxADCChEightHiAlarmEnabled, aprisaXERxADCChEightHiAlarmThreshold, aprisaXERxADCChEightHiAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXERx receiver ADC Ch Eight voltage too high alarm group." ::= { aprisaXEGroups 291 } aprisaXERxADCChEightLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 36 } aprisaXERxADCChEightLoAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the receiver ADC Ch Eight voltage too low alarm." ::= { aprisaXERxADCChEightLoAlarm 1 } aprisaXERxADCChEightLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the receiver ADC Ch Eight voltage too low alarm." ::= { aprisaXERxADCChEightLoAlarm 2 } aprisaXERxADCChEightLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the receiver ADC Ch Eight voltage too low alarm." ::= { aprisaXERxADCChEightLoAlarm 3 } aprisaXERxADCChEightLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the receiver ADC Ch Eight voltage too low alarm is enabled." ::= { aprisaXERxADCChEightLoAlarm 4 } aprisaXERxADCChEightLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Eight voltage too low alarm will be set." ::= { aprisaXERxADCChEightLoAlarm 5 } aprisaXERxADCChEightLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Eight voltage too low will be cleared." ::= { aprisaXERxADCChEightLoAlarm 6 } aprisaXERxADCChEightLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxADCChEightLoAlarmName, aprisaXERxADCChEightLoAlarmStatus, aprisaXERxADCChEightLoAlarmSeverity, aprisaXERxADCChEightLoAlarmEnabled, aprisaXERxADCChEightLoAlarmThreshold, aprisaXERxADCChEightLoAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXERx receiver ADC Ch Eight voltage too High alarm group." ::= { aprisaXEGroups 292 } aprisaXERxADCChNineHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 37 } aprisaXERxADCChNineHiAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the receiver ADC Ch Nine voltage too high alarm." ::= { aprisaXERxADCChNineHiAlarm 1 } aprisaXERxADCChNineHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the receiver ADC Ch Nine voltage too high alarm." ::= { aprisaXERxADCChNineHiAlarm 2 } aprisaXERxADCChNineHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the receiver ADC Ch Nine voltage too high alarm." ::= { aprisaXERxADCChNineHiAlarm 3 } aprisaXERxADCChNineHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the receiver ADC Ch Nine voltage too high alarm is enabled." ::= { aprisaXERxADCChNineHiAlarm 4 } aprisaXERxADCChNineHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the receiver ADC Ch Nine voltage too high alarm will be set." ::= { aprisaXERxADCChNineHiAlarm 5 } aprisaXERxADCChNineHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the receiver ADC Ch Nine voltage too high will be cleared." ::= { aprisaXERxADCChNineHiAlarm 6 } aprisaXERxADCChNineHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxADCChNineHiAlarmName, aprisaXERxADCChNineHiAlarmStatus, aprisaXERxADCChNineHiAlarmSeverity, aprisaXERxADCChNineHiAlarmEnabled, aprisaXERxADCChNineHiAlarmThreshold, aprisaXERxADCChNineHiAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXERx receiver ADC Ch Nine voltage too high alarm group." ::= { aprisaXEGroups 293 } aprisaXERxADCChNineLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 38 } aprisaXERxADCChNineLoAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the receiver ADC Ch Nine voltage too low alarm." ::= { aprisaXERxADCChNineLoAlarm 1 } aprisaXERxADCChNineLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the receiver ADC Ch Nine voltage too low alarm." ::= { aprisaXERxADCChNineLoAlarm 2 } aprisaXERxADCChNineLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the receiver ADC Ch Nine voltage too low alarm." ::= { aprisaXERxADCChNineLoAlarm 3 } aprisaXERxADCChNineLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the receiver ADC Ch Nine voltage too low alarm is enabled." ::= { aprisaXERxADCChNineLoAlarm 4 } aprisaXERxADCChNineLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Nine voltage too low alarm will be set." ::= { aprisaXERxADCChNineLoAlarm 5 } aprisaXERxADCChNineLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Nine voltage too low will be cleared." ::= { aprisaXERxADCChNineLoAlarm 6 } aprisaXERxADCChNineLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxADCChNineLoAlarmName, aprisaXERxADCChNineLoAlarmStatus, aprisaXERxADCChNineLoAlarmSeverity, aprisaXERxADCChNineLoAlarmEnabled, aprisaXERxADCChNineLoAlarmThreshold, aprisaXERxADCChNineLoAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXERx receiver ADC Ch Nine voltage too High alarm group." ::= { aprisaXEGroups 294 } aprisaXERxADCChTenHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 39 } aprisaXERxADCChTenHiAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the receiver ADC Ch Ten voltage too high alarm." ::= { aprisaXERxADCChTenHiAlarm 1 } aprisaXERxADCChTenHiAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the receiver ADC Ch Ten voltage too high alarm." ::= { aprisaXERxADCChTenHiAlarm 2 } aprisaXERxADCChTenHiAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the receiver ADC Ch Ten voltage too high alarm." ::= { aprisaXERxADCChTenHiAlarm 3 } aprisaXERxADCChTenHiAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the receiver ADC Ch Ten voltage too high alarm is enabled." ::= { aprisaXERxADCChTenHiAlarm 4 } aprisaXERxADCChTenHiAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the receiver ADC Ch Ten voltage too high alarm will be set." ::= { aprisaXERxADCChTenHiAlarm 5 } aprisaXERxADCChTenHiAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at which the receiver ADC Ch Ten voltage too high will be cleared." ::= { aprisaXERxADCChTenHiAlarm 6 } aprisaXERxADCChTenHiAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxADCChTenHiAlarmName, aprisaXERxADCChTenHiAlarmStatus, aprisaXERxADCChTenHiAlarmSeverity, aprisaXERxADCChTenHiAlarmEnabled, aprisaXERxADCChTenHiAlarmThreshold, aprisaXERxADCChTenHiAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXERx receiver ADC Ch Ten voltage too high alarm group." ::= { aprisaXEGroups 295 } aprisaXERxADCChTenLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 40 } aprisaXERxADCChTenLoAlarmName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the receiver ADC Ch Ten voltage too low alarm." ::= { aprisaXERxADCChTenLoAlarm 1 } aprisaXERxADCChTenLoAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the receiver ADC Ch Ten voltage too low alarm." ::= { aprisaXERxADCChTenLoAlarm 2 } aprisaXERxADCChTenLoAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the receiver ADC Ch Ten voltage too low alarm." ::= { aprisaXERxADCChTenLoAlarm 3 } aprisaXERxADCChTenLoAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the receiver ADC Ch Ten voltage too low alarm is enabled." ::= { aprisaXERxADCChTenLoAlarm 4 } aprisaXERxADCChTenLoAlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Ten voltage too low alarm will be set." ::= { aprisaXERxADCChTenLoAlarm 5 } aprisaXERxADCChTenLoAlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Ten voltage too low will be cleared." ::= { aprisaXERxADCChTenLoAlarm 6 } aprisaXERxADCChTenLoAlarmsGroup OBJECT-GROUP OBJECTS { aprisaXERxADCChTenLoAlarmName, aprisaXERxADCChTenLoAlarmStatus, aprisaXERxADCChTenLoAlarmSeverity, aprisaXERxADCChTenLoAlarmEnabled, aprisaXERxADCChTenLoAlarmThreshold, aprisaXERxADCChTenLoAlarmClearThreshold } STATUS current DESCRIPTION "The aprisaXERx receiver ADC Ch Ten voltage too High alarm group." ::= { aprisaXEGroups 296 } -- *************************************************************************** -- End of the Generic Receiver alarms -- *************************************************************************** -- *************************************************************************** -- Modem alarms -- *************************************************************************** aprisaXEModemAlarms OBJECT IDENTIFIER ::= { aprisaXELinkAlarms 10 } aprisaXEModemSyncAlarm OBJECT IDENTIFIER ::= { aprisaXEModemAlarms 1 } aprisaXEModemSyncAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the loss of modem sync alarm." ::= { aprisaXEModemSyncAlarm 1 } aprisaXEModemSyncAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the loss of modem sync alarm." ::= { aprisaXEModemSyncAlarm 2 } aprisaXEModemSyncAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the loss of modem sync alarm is enabled." ::= { aprisaXEModemSyncAlarm 3 } -- *************************************************************************** -- End of Modem alarms -- *************************************************************************** -- *************************************************************************** -- Quad E1 Alarms -- *************************************************************************** aprisaXEQuadJetBoardTable OBJECT-TYPE SYNTAX SEQUENCE OF AprisaXEQuadJetBoardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of Quad E1 card specific configuration details." ::= { aprisaXEObjects 87 } aprisaXEQuadJetBoardEntry OBJECT-TYPE SYNTAX AprisaXEQuadJetBoardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Quad E1 configuration details." INDEX { aprisaXEQuadJetBoardTableIndex } ::= { aprisaXEQuadJetBoardTable 1 } AprisaXEQuadJetBoardEntry ::= SEQUENCE { aprisaXEQuadJetBoardTableIndex INTEGER } aprisaXEQuadJetBoardTableIndex OBJECT-TYPE SYNTAX AprisaXESlotNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Quad E1 board indexed by slot." ::= { aprisaXEQuadJetBoardEntry 1 } aprisaXEQuadJetPortTable OBJECT-TYPE SYNTAX SEQUENCE OF AprisaXEQuadJetPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table based on slot and port of QuadJet cards alarms." ::= { aprisaXEObjects 88 } aprisaXEQuadJetPortEntry OBJECT-TYPE SYNTAX AprisaXEQuadJetPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Quad E1 port alarms." INDEX { aprisaXEQuadJetPortTableSlot, aprisaXEQuadJetPortTablePort } ::= { aprisaXEQuadJetPortTable 1 } AprisaXEQuadJetPortEntry ::= SEQUENCE { aprisaXEQuadJetPortTableSlot INTEGER, aprisaXEQuadJetPortTablePort INTEGER, aprisaXEQuadJetLOFAlarmStatus INTEGER, aprisaXEQuadJetLOFAlarmSeverity INTEGER, aprisaXEQuadJetLOFAlarmEnabled INTEGER, aprisaXEQuadJetAISAlarmStatus INTEGER, aprisaXEQuadJetAISAlarmSeverity INTEGER, aprisaXEQuadJetAISAlarmEnabled INTEGER, aprisaXEQuadJetRAIAlarmStatus INTEGER, aprisaXEQuadJetRAIAlarmSeverity INTEGER, aprisaXEQuadJetRAIAlarmEnabled INTEGER, aprisaXEQuadJetRMAIAlarmStatus INTEGER, aprisaXEQuadJetRMAIAlarmSeverity INTEGER, aprisaXEQuadJetRMAIAlarmEnabled INTEGER, aprisaXEQuadJetTS16AISAlarmStatus INTEGER, aprisaXEQuadJetTS16AISAlarmSeverity INTEGER, aprisaXEQuadJetTS16AISAlarmEnabled INTEGER, aprisaXEQuadJetTS16LOSAlarmStatus INTEGER, aprisaXEQuadJetTS16LOSAlarmSeverity INTEGER, aprisaXEQuadJetTS16LOSAlarmEnabled INTEGER, aprisaXEQuadJetLOSAlarmStatus INTEGER, aprisaXEQuadJetLOSAlarmSeverity INTEGER, aprisaXEQuadJetLOSAlarmEnabled INTEGER, aprisaXEQuadJetCRC4AlarmStatus INTEGER, aprisaXEQuadJetCRC4AlarmSeverity INTEGER, aprisaXEQuadJetCRC4AlarmEnabled INTEGER, aprisaXEQuadJetCRC4AlarmThreshold Integer32, aprisaXEQuadJetCRC4AlarmClearThreshold Integer32 } aprisaXEQuadJetPortTableSlot OBJECT-TYPE SYNTAX AprisaXESlotNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Port table index based on slot number." ::= { aprisaXEQuadJetPortEntry 1 } aprisaXEQuadJetPortTablePort OBJECT-TYPE SYNTAX AprisaXEPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Port table index based on port number." ::= { aprisaXEQuadJetPortEntry 2 } aprisaXEQuadJetLOFAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Red alarm status." ::= { aprisaXEQuadJetPortEntry 3 } aprisaXEQuadJetLOFAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "Red alarm severity." ::= { aprisaXEQuadJetPortEntry 4 } aprisaXEQuadJetLOFAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "Red alarm enabled or disabled." ::= { aprisaXEQuadJetPortEntry 5 } aprisaXEQuadJetAISAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "AIS alarm status." ::= { aprisaXEQuadJetPortEntry 6 } aprisaXEQuadJetAISAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "AIS alarm severity." ::= { aprisaXEQuadJetPortEntry 7 } aprisaXEQuadJetAISAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "AIS alarm enabled or disabled." ::= { aprisaXEQuadJetPortEntry 8 } aprisaXEQuadJetRAIAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "RAI alarm status." ::= { aprisaXEQuadJetPortEntry 9 } aprisaXEQuadJetRAIAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "RAI alarm severity." ::= { aprisaXEQuadJetPortEntry 10 } aprisaXEQuadJetRAIAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "RAI alarm enabled or disabled." ::= { aprisaXEQuadJetPortEntry 11 } aprisaXEQuadJetRMAIAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "RMAI alarm status." ::= { aprisaXEQuadJetPortEntry 12 } aprisaXEQuadJetRMAIAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "RMAI alarm severity." ::= { aprisaXEQuadJetPortEntry 13 } aprisaXEQuadJetRMAIAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "RMAI alarm enabled or disabled." ::= { aprisaXEQuadJetPortEntry 14 } aprisaXEQuadJetTS16AISAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "TS16 AIS alarm status." ::= { aprisaXEQuadJetPortEntry 15 } aprisaXEQuadJetTS16AISAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "TS16 AIS alarm severity." ::= { aprisaXEQuadJetPortEntry 16 } aprisaXEQuadJetTS16AISAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "TS16 AIS alarm enabled or disabled." ::= { aprisaXEQuadJetPortEntry 17 } aprisaXEQuadJetTS16LOSAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "TS16 LOS alarm status." ::= { aprisaXEQuadJetPortEntry 18 } aprisaXEQuadJetTS16LOSAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "TS16 LOS alarm severity." ::= { aprisaXEQuadJetPortEntry 19 } aprisaXEQuadJetTS16LOSAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "TS16 LOS alarm enabled or disabled." ::= { aprisaXEQuadJetPortEntry 20 } aprisaXEQuadJetLOSAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "LOS alarm status." ::= { aprisaXEQuadJetPortEntry 21 } aprisaXEQuadJetLOSAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "LOS alarm severity." ::= { aprisaXEQuadJetPortEntry 22 } aprisaXEQuadJetLOSAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "LOS alarm enabled or disabled." ::= { aprisaXEQuadJetPortEntry 23 } aprisaXEQuadJetCRC4AlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "CRC4 alarm status." ::= { aprisaXEQuadJetPortEntry 24 } aprisaXEQuadJetCRC4AlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "CRC4 alarm severity." ::= { aprisaXEQuadJetPortEntry 25 } aprisaXEQuadJetCRC4AlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "CRC4 alarm enabled or disabled." ::= { aprisaXEQuadJetPortEntry 26 } aprisaXEQuadJetCRC4AlarmThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "CRC4 Threshold value for counter to alarm at." ::= { aprisaXEQuadJetPortEntry 27 } aprisaXEQuadJetCRC4AlarmClearThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "CRC4 Threshold at which alarm clears." ::= { aprisaXEQuadJetPortEntry 28 } aprisaXEQuadJetIFConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF AprisaXEQuadJetIFConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Switch data table which describes the allocation of user data on to the TDM busses." ::= { aprisaXEObjects 90 } aprisaXEQuadJetIFConfigEntry OBJECT-TYPE SYNTAX AprisaXEQuadJetIFConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Quad JET config data." INDEX { aprisaXEQuadJetIFConfigSlotIndex, aprisaXEQuadJetIFConfigPortIndex } ::= { aprisaXEQuadJetIFConfigTable 1 } AprisaXEQuadJetIFConfigEntry ::= SEQUENCE { aprisaXEQuadJetIFConfigSlotIndex INTEGER, aprisaXEQuadJetIFConfigPortIndex INTEGER, aprisaXEQuadJetTrafficType INTEGER, aprisaXEQuadJetLoopback INTEGER, aprisaXEQuadJetLineEncoding INTEGER, aprisaXEQuadJetPcmMode INTEGER, aprisaXEQuadJetClockSource INTEGER, aprisaXEQuadJetLineRadioLoopback INTEGER, aprisaXEQuadJetTxWaveFormShaper INTEGER, aprisaXEQuadJetMultiframeEnable INTEGER } aprisaXEQuadJetIFConfigSlotIndex OBJECT-TYPE SYNTAX AprisaXESlotNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Index to the port table based on port number." ::= { aprisaXEQuadJetIFConfigEntry 1 } aprisaXEQuadJetIFConfigPortIndex OBJECT-TYPE SYNTAX AprisaXEPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Index to the port table based on port number." ::= { aprisaXEQuadJetIFConfigEntry 2 } aprisaXEQuadJetTrafficType OBJECT-TYPE SYNTAX AprisaXEQuadJetTrafficType MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the traffic type on a Quad JET port." ::= { aprisaXEQuadJetIFConfigEntry 3 } aprisaXEQuadJetLoopback OBJECT-TYPE SYNTAX FourRFLoopback MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Controls the traffic loopback on a Quad JET port." ::= { aprisaXEQuadJetIFConfigEntry 4 } aprisaXEQuadJetLineEncoding OBJECT-TYPE SYNTAX AprisaXEQuadJetLineEncoding MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the line encoding, the default is HDB3 for E1, B8ZS for T1." ::= { aprisaXEQuadJetIFConfigEntry 5 } aprisaXEQuadJetPcmMode OBJECT-TYPE SYNTAX AprisaXEPcmMode MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the PCM mode, PCM31 or PCM30C." ::= { aprisaXEQuadJetIFConfigEntry 6 } aprisaXEQuadJetClockSource OBJECT-TYPE SYNTAX FourRFNetworkClockSelect MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the port drives the clock soure or not." ::= { aprisaXEQuadJetIFConfigEntry 7 } aprisaXEQuadJetLineRadioLoopback OBJECT-TYPE SYNTAX AprisaXEQuadJetLoopbacks MAX-ACCESS read-write STATUS current DESCRIPTION "This indicates the E1 loopback setting on a port; OFF, Line or Radio Facing." ::= { aprisaXEQuadJetIFConfigEntry 8 } aprisaXEQuadJetTxWaveFormShaper OBJECT-TYPE SYNTAX AprisaXEQuadJetWaveFormShapers MAX-ACCESS read-write STATUS current DESCRIPTION "This indicates the T1 Tx Waveform Shaper for a port; 0~133 ft, 133~266 ft, 266~399 ft, 399~533 ft, 533~655 ft." ::= { aprisaXEQuadJetIFConfigEntry 9 } aprisaXEQuadJetMultiframeEnable OBJECT-TYPE SYNTAX AprisaXEQuadJetMultiframeEnable MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether support is enabled for transport of T1 SF and ESF multiframe sync for a port." ::= { aprisaXEQuadJetIFConfigEntry 10 } -- E1 Cross connection table, this maps cross-connection identifiers to -- the matching E1 slot and port. aprisaXEQuadJetIFConnectionTable OBJECT-TYPE SYNTAX SEQUENCE OF AprisaXEQuadJetIFConnectionTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interface connection table which holds all the cross connect information for the E1 card." ::= { aprisaXEObjects 91 } aprisaXEQuadJetIFConnectionTableEntry OBJECT-TYPE SYNTAX AprisaXEQuadJetIFConnectionTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Quad JET cross connection data." INDEX { aprisaXEQuadJetIFConnectionID, aprisaXEQuadJetIFConnectionAggregateID } ::= { aprisaXEQuadJetIFConnectionTable 1 } AprisaXEQuadJetIFConnectionTableEntry ::= SEQUENCE { aprisaXEQuadJetIFConnectionID INTEGER, aprisaXEQuadJetIFConnectionAggregateID INTEGER, aprisaXEQuadJetIFConnectionSlot INTEGER, aprisaXEQuadJetIFConnectionE1Port INTEGER, aprisaXEQuadJetIFConnectionType INTEGER } aprisaXEQuadJetIFConnectionID OBJECT-TYPE SYNTAX AprisaXEConnectionID MAX-ACCESS read-only STATUS current DESCRIPTION "Backplane Connection ID." ::= { aprisaXEQuadJetIFConnectionTableEntry 1 } aprisaXEQuadJetIFConnectionAggregateID OBJECT-TYPE SYNTAX AprisaXEConnectionID MAX-ACCESS read-only STATUS current DESCRIPTION "Aggregate ID, 0 if an unframed connection." ::= { aprisaXEQuadJetIFConnectionTableEntry 2 } aprisaXEQuadJetIFConnectionSlot OBJECT-TYPE SYNTAX AprisaXESlotNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Slot number that this card is in." ::= { aprisaXEQuadJetIFConnectionTableEntry 3 } aprisaXEQuadJetIFConnectionE1Port OBJECT-TYPE SYNTAX AprisaXEPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Port number associated with this connection." ::= { aprisaXEQuadJetIFConnectionTableEntry 4 } aprisaXEQuadJetIFConnectionType OBJECT-TYPE SYNTAX AprisaXEQuadJetConnectionType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether the connection is for data or CAS signalling." ::= { aprisaXEQuadJetIFConnectionTableEntry 5 } aprisaXEQuadJetIFConnectionControl OBJECT IDENTIFIER ::= { aprisaXEObjects 93 } aprisaXEQuadJetIFControlConnectionID OBJECT-TYPE SYNTAX AprisaXEConnectionID MAX-ACCESS read-write STATUS current DESCRIPTION "Backplane Connection ID." ::= { aprisaXEQuadJetIFConnectionControl 1 } aprisaXEQuadJetIFControlAggregateID OBJECT-TYPE SYNTAX AprisaXEConnectionID MAX-ACCESS read-write STATUS current DESCRIPTION "Aggregate Connection ID." ::= { aprisaXEQuadJetIFConnectionControl 2 } aprisaXEQuadJetIFConnectionControlSlot OBJECT-TYPE SYNTAX AprisaXESlotNumber MAX-ACCESS read-write STATUS current DESCRIPTION "Slot number that this card is in." ::= { aprisaXEQuadJetIFConnectionControl 3 } aprisaXEQuadJetIFConnectionControlE1Port OBJECT-TYPE SYNTAX AprisaXEPortNumber MAX-ACCESS read-write STATUS current DESCRIPTION "Port number associated with this connection." ::= { aprisaXEQuadJetIFConnectionControl 4 } aprisaXEQuadJetIFConnectionControlType OBJECT-TYPE SYNTAX AprisaXEQuadJetConnectionType MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether the connection is for data or CAS signalling." ::= { aprisaXEQuadJetIFConnectionControl 5 } aprisaXEQuadJetIFConnectionControlCommand OBJECT-TYPE SYNTAX INTEGER { noCommand (0), addCommand (1), deleteCommand (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Command to send to act upon the rows in the QuedJet Interface Connection table." ::= { aprisaXEQuadJetIFConnectionControl 6 } -- *************************************************************************** -- End Quad JET -- *************************************************************************** -- *************************************************************************** -- Ethernet -- *************************************************************************** aprisaXEEthernetConfiguration OBJECT IDENTIFIER ::= { aprisaXEObjects 95 } aprisaXEEthernetBandwidth OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This controls the bandwidth allocated to ethernet in kbps, the minimum block is 8kbps, values will be rounded up to the nearest 8kbps." ::= { aprisaXEEthernetConfiguration 1 } aprisaXEEthernetManagementBandwidth OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This controls the bandwidth available to management traffic, a minimum of 8kbps is required. Values will be rounded up to the nearest 8kbps." ::= { aprisaXEEthernetConfiguration 2 } aprisaXEEthernetCustomerConnectionID OBJECT-TYPE SYNTAX AprisaXEConnectionID MAX-ACCESS read-write STATUS current DESCRIPTION "Backplane connection ID for Customer bandwidth." ::= { aprisaXEEthernetConfiguration 3 } aprisaXEEthernetPBCConnectionID OBJECT-TYPE SYNTAX AprisaXEConnectionID MAX-ACCESS read-write STATUS current DESCRIPTION "Backplane connection ID for Private Back Channel management bandwidth." ::= { aprisaXEEthernetConfiguration 4 } -- For now a simple table for basic control/status of the hub ports. Later -- we probably want to implement the EtherLike-MIB. aprisaXEEthernetPortTable OBJECT-TYPE SYNTAX SEQUENCE OF AprisaXEEthernetPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table used to control and monitor basic ethernet features on the 4-port hub." ::= { aprisaXEObjects 96 } aprisaXEEthernetPortEntry OBJECT-TYPE SYNTAX AprisaXEEthernetPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Ethernet port status and configuration." INDEX { aprisaXEEthernetPortIndex } ::= { aprisaXEEthernetPortTable 1 } AprisaXEEthernetPortEntry ::= SEQUENCE { aprisaXEEthernetPortIndex INTEGER, aprisaXEEthernetAutonegotiationStatus INTEGER, aprisaXEEthernetRemoteFaultStatus INTEGER, aprisaXEEthernetLinkStatus INTEGER, aprisaXEEthernetJabberStatus INTEGER, aprisaXEEthernetSpeed INTEGER, aprisaXEEthernetDuplexMode INTEGER } aprisaXEEthernetPortIndex OBJECT-TYPE SYNTAX INTEGER ( 1..4 ) MAX-ACCESS read-only STATUS current DESCRIPTION "The port index, there are four ports on the hub." ::= { aprisaXEEthernetPortEntry 1 } aprisaXEEthernetAutonegotiationStatus OBJECT-TYPE SYNTAX INTEGER { autoNegotiationNotComplete (0), autoNegotiationComplete (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the port auto-negotiation." ::= { aprisaXEEthernetPortEntry 2 } aprisaXEEthernetRemoteFaultStatus OBJECT-TYPE SYNTAX INTEGER { remoteFaultNotDetected (0), remoteFaultDetected (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the port remote fault detection." ::= { aprisaXEEthernetPortEntry 3 } aprisaXEEthernetLinkStatus OBJECT-TYPE SYNTAX INTEGER { down (0), up (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the port link." ::= { aprisaXEEthernetPortEntry 4 } aprisaXEEthernetJabberStatus OBJECT-TYPE SYNTAX INTEGER { jabberNotDetected (0), jabberDetected (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Has jabber been detected on the port?." ::= { aprisaXEEthernetPortEntry 5 } aprisaXEEthernetSpeed OBJECT-TYPE SYNTAX INTEGER { mbps10 (0), mbps100 (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current port speed, 10 or 100 Mbps." ::= { aprisaXEEthernetPortEntry 6 } aprisaXEEthernetDuplexMode OBJECT-TYPE SYNTAX INTEGER { halfDuplex (0), fullDuplex (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "The current port duplex mode." ::= { aprisaXEEthernetPortEntry 7 } -- *************************************************************************** -- End Ethernet -- *************************************************************************** -- *************************************************************************** -- Interface Status -- *************************************************************************** -- -- A table which maintains the status of the interface cards, the amount of -- bandwidth allocated per port and the overall alarm status. -- aprisaXEInterfaceTable OBJECT-TYPE SYNTAX SEQUENCE OF AprisaXEInterfaceTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table used to monitor the current interface status." ::= { aprisaXEObjects 100 } aprisaXEInterfaceTableEntry OBJECT-TYPE SYNTAX AprisaXEInterfaceTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interface bandwidth and status." INDEX { aprisaXEInterfaceIndex } ::= { aprisaXEInterfaceTable 1 } AprisaXEInterfaceTableEntry ::= SEQUENCE { aprisaXEInterfaceIndex INTEGER, aprisaXEInterfaceType INTEGER, aprisaXEInterfaceAlarmStatus INTEGER, aprisaXEInterfacePort1Bandwidth Unsigned32, aprisaXEInterfacePort2Bandwidth Unsigned32, aprisaXEInterfacePort3Bandwidth Unsigned32, aprisaXEInterfacePort4Bandwidth Unsigned32 } aprisaXEInterfaceIndex OBJECT-TYPE SYNTAX AprisaXESlotNumber MAX-ACCESS read-only STATUS current DESCRIPTION "The slot containing the interface card, slots 0 to 8 (AUX or A-H) inclusive may contain interface cards." ::= { aprisaXEInterfaceTableEntry 1 } aprisaXEInterfaceType OBJECT-TYPE SYNTAX AprisaXECardType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the type of interface card." ::= { aprisaXEInterfaceTableEntry 2 } aprisaXEInterfaceAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current alarm status for the interface." ::= { aprisaXEInterfaceTableEntry 3 } aprisaXEInterfacePort1Bandwidth OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the bandwidth allocated to port 1." ::= { aprisaXEInterfaceTableEntry 4 } aprisaXEInterfacePort2Bandwidth OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the bandwidth allocated to port 2." ::= { aprisaXEInterfaceTableEntry 5 } aprisaXEInterfacePort3Bandwidth OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the bandwidth allocated to port 3." ::= { aprisaXEInterfaceTableEntry 6 } aprisaXEInterfacePort4Bandwidth OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the bandwidth allocated to port 4." ::= { aprisaXEInterfaceTableEntry 7 } -- *************************************************************************** -- End Interface Status -- *************************************************************************** -- *************************************************************************** -- 4 Wire Interfaces -- *************************************************************************** aprisaXE4WirePortControlTable OBJECT-TYPE SYNTAX SEQUENCE OF AprisaXE4WirePortControlTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Status and Control table for 4Wire." ::= { aprisaXEObjects 110 } aprisaXE4WirePortControlTableEntry OBJECT-TYPE SYNTAX AprisaXE4WirePortControlTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries for 4wire table." INDEX { aprisaXE4WireSlotIndex, aprisaXE4WirePortIndex } ::= { aprisaXE4WirePortControlTable 1 } AprisaXE4WirePortControlTableEntry ::= SEQUENCE { aprisaXE4WireConnectionID INTEGER, aprisaXE4WireSlotIndex INTEGER, aprisaXE4WirePortIndex INTEGER, aprisaXE4WireLoopback INTEGER, aprisaXE4WireAdpcmCompression INTEGER, aprisaXE4WireRxGain INTEGER, aprisaXE4WireTxGain INTEGER, aprisaXE4WireEInvert INTEGER, aprisaXE4WireMInvert INTEGER, aprisaXE4WireSignalling INTEGER, aprisaXE4WireSignallingConnectionID INTEGER, aprisaXE4WireInputLevel INTEGER, aprisaXE4WireOutputLevel INTEGER } aprisaXE4WireConnectionID OBJECT-TYPE SYNTAX AprisaXEConnectionID MAX-ACCESS read-write STATUS current DESCRIPTION "Associated cross-connect Backplane Connection ID." ::= { aprisaXE4WirePortControlTableEntry 1 } aprisaXE4WireSlotIndex OBJECT-TYPE SYNTAX AprisaXESlotNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Slot index for 4wire Status Control table." ::= { aprisaXE4WirePortControlTableEntry 2 } aprisaXE4WirePortIndex OBJECT-TYPE SYNTAX AprisaXEPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Channel index for 4 Wire Control Status table." ::= { aprisaXE4WirePortControlTableEntry 3 } aprisaXE4WireLoopback OBJECT-TYPE SYNTAX FourRFLoopback MAX-ACCESS read-write STATUS current DESCRIPTION "Loopback control on or off for channels." ::= { aprisaXE4WirePortControlTableEntry 4 } aprisaXE4WireAdpcmCompression OBJECT-TYPE SYNTAX AprisaXEAdpcmCompression MAX-ACCESS read-write STATUS current DESCRIPTION "ADPCM compression 16, 24, 32, 64 kbps or none." DEFVAL { none } ::= { aprisaXE4WirePortControlTableEntry 5 } aprisaXE4WireRxGain OBJECT-TYPE SYNTAX AprisaXE4WRxGain MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Rx gain +4 dB to -14 dB in 0.5 dB steps." ::= { aprisaXE4WirePortControlTableEntry 6 } aprisaXE4WireTxGain OBJECT-TYPE SYNTAX AprisaXE4WTxGain MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Tx gain +14 dB to -4 dB in half dB steps." ::= { aprisaXE4WirePortControlTableEntry 7 } aprisaXE4WireEInvert OBJECT-TYPE SYNTAX AprisaXESignalState MAX-ACCESS read-write STATUS current DESCRIPTION "Controls E on each channel for NORMAL or INVERT polarity." ::= { aprisaXE4WirePortControlTableEntry 8 } aprisaXE4WireMInvert OBJECT-TYPE SYNTAX AprisaXESignalState MAX-ACCESS read-write STATUS current DESCRIPTION "Controls M on each channel for NORMAL or INVERT polarity." ::= { aprisaXE4WirePortControlTableEntry 9 } aprisaXE4WireSignalling OBJECT-TYPE SYNTAX INTEGER { signallingOff (0), signallingOn (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables or disables E&M signalling for the port." ::= { aprisaXE4WirePortControlTableEntry 10 } aprisaXE4WireSignallingConnectionID OBJECT-TYPE SYNTAX AprisaXEConnectionID MAX-ACCESS read-write STATUS current DESCRIPTION "Associated signalling cross-connect Backplane Connection ID." ::= { aprisaXE4WirePortControlTableEntry 11 } aprisaXE4WireInputLevel OBJECT-TYPE SYNTAX AprisaXE4WInputLevel MAX-ACCESS read-write STATUS current DESCRIPTION "Input Level -14.0 dBr to +4.0 dBr in half dB steps." ::= { aprisaXE4WirePortControlTableEntry 12 } aprisaXE4WireOutputLevel OBJECT-TYPE SYNTAX AprisaXE4WOutputLevel MAX-ACCESS read-write STATUS current DESCRIPTION "Output Level -14.0 dBr to +4.0 dBr in 0.5 dB steps." ::= { aprisaXE4WirePortControlTableEntry 13 } -- -- End of aprisaXE4WirePortControlTable -- aprisaXE4WireStatusControlTable OBJECT-TYPE SYNTAX SEQUENCE OF AprisaXE4WireStatusControlTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Overall card control and status." ::= { aprisaXEObjects 121 } aprisaXE4WireStatusControlTableEntry OBJECT-TYPE SYNTAX AprisaXE4WireStatusControlTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Status control entries." INDEX { aprisaXE4WireStatusControlSlotIndex } ::= { aprisaXE4WireStatusControlTable 1 } AprisaXE4WireStatusControlTableEntry ::= SEQUENCE { aprisaXE4WireStatusControlSlotIndex INTEGER, aprisaXE4WirePcmLaw INTEGER } aprisaXE4WireStatusControlSlotIndex OBJECT-TYPE SYNTAX AprisaXESlotNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Index for table." ::= { aprisaXE4WireStatusControlTableEntry 1 } aprisaXE4WirePcmLaw OBJECT-TYPE SYNTAX AprisaXEPcmLaw MAX-ACCESS read-write STATUS current DESCRIPTION "Sets A-law or u-law." ::= { aprisaXE4WireStatusControlTableEntry 2 } -- *************************************************************************** -- End 4 Wire -- *************************************************************************** -- *************************************************************************** -- FXO -- *************************************************************************** aprisaXEFXOPortControlTable OBJECT-TYPE SYNTAX SEQUENCE OF AprisaXEFXOPortControlTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port Control table for FXO." ::= { aprisaXEObjects 130 } aprisaXEFXOPortControlTableEntry OBJECT-TYPE SYNTAX AprisaXEFXOPortControlTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries for FXO table." INDEX { aprisaXEFXOPortControlSlotIndex, aprisaXEFXOPortIndex } ::= { aprisaXEFXOPortControlTable 1 } AprisaXEFXOPortControlTableEntry ::= SEQUENCE { aprisaXEFXOPortControlSlotIndex INTEGER, aprisaXEFXOPortIndex INTEGER, aprisaXEFXOLoopback INTEGER, aprisaXEFXOAdpcmCompression INTEGER, aprisaXEFXORxGain INTEGER, aprisaXEFXOTxGain INTEGER, aprisaXEFXOConnectionID INTEGER, aprisaXEFXOSignallingConnectionID INTEGER, aprisaXEFXOInputLevel INTEGER, aprisaXEFXOOutputLevel INTEGER } aprisaXEFXOPortControlSlotIndex OBJECT-TYPE SYNTAX AprisaXESlotNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Slot index for FXO Control table." ::= { aprisaXEFXOPortControlTableEntry 1 } aprisaXEFXOPortIndex OBJECT-TYPE SYNTAX AprisaXEPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Port index for FXO Control table." ::= { aprisaXEFXOPortControlTableEntry 2 } aprisaXEFXOLoopback OBJECT-TYPE SYNTAX FourRFLoopback MAX-ACCESS read-write STATUS current DESCRIPTION "Loopback control on or off for ports." ::= { aprisaXEFXOPortControlTableEntry 3 } aprisaXEFXOAdpcmCompression OBJECT-TYPE SYNTAX AprisaXEAdpcmCompression MAX-ACCESS read-write STATUS current DESCRIPTION "ADPCM compression 16, 24, 32, 64 kbps or none." DEFVAL { none } ::= { aprisaXEFXOPortControlTableEntry 4 } aprisaXEFXORxGain OBJECT-TYPE SYNTAX INTEGER { fxopos100 (0), fxopos95 (1), fxopos90 (2), fxopos85 (3), fxopos80 (4), fxopos75 (5), fxopos70 (6), fxopos65 (7), fxopos60 (8), fxopos55 (9), fxopos50 (10), fxopos45 (11), fxopos40 (12), fxopos35 (13), fxopos30 (14), fxopos25 (15), fxopos20 (16), fxopos15 (17), fxopos10 (18), fxopos05 (19), fxopos0 (20), fxoneg05 (21), fxoneg10 (22), fxoneg15 (23), fxoneg20 (24), fxoneg25 (25), fxoneg30 (26), fxoneg35 (27), fxoneg40 (28), fxoneg45 (29), fxoneg50 (30), fxoneg55 (31), fxoneg60 (32), fxoneg65 (33), fxoneg70 (34), fxoneg75 (35), fxoneg80 (36), fxoneg85 (37), fxoneg90 (38), fxoneg95 (39), fxoneg100 (40) } MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Rx gain -10 dB to 10 dB in 0.5 dB steps." ::= { aprisaXEFXOPortControlTableEntry 5 } aprisaXEFXOTxGain OBJECT-TYPE SYNTAX INTEGER { fxopos100 (0), fxopos95 (1), fxopos90 (2), fxopos85 (3), fxopos80 (4), fxopos75 (5), fxopos70 (6), fxopos65 (7), fxopos60 (8), fxopos55 (9), fxopos50 (10), fxopos45 (11), fxopos40 (12), fxopos35 (13), fxopos30 (14), fxopos25 (15), fxopos20 (16), fxopos15 (17), fxopos10 (18), fxopos05 (19), fxopos0 (20), fxoneg05 (21), fxoneg10 (22), fxoneg15 (23), fxoneg20 (24), fxoneg25 (25), fxoneg30 (26), fxoneg35 (27), fxoneg40 (28), fxoneg45 (29), fxoneg50 (30), fxoneg55 (31), fxoneg60 (32), fxoneg65 (33), fxoneg70 (34), fxoneg75 (35), fxoneg80 (36), fxoneg85 (37), fxoneg90 (38), fxoneg95 (39), fxoneg100 (40) } MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Tx gain -10 dB to 10 dB in half dB steps." ::= { aprisaXEFXOPortControlTableEntry 6 } aprisaXEFXOConnectionID OBJECT-TYPE SYNTAX AprisaXEConnectionID MAX-ACCESS read-write STATUS current DESCRIPTION "Associated cross-connect Backplane Connection ID." ::= { aprisaXEFXOPortControlTableEntry 7 } aprisaXEFXOSignallingConnectionID OBJECT-TYPE SYNTAX AprisaXEConnectionID MAX-ACCESS read-write STATUS current DESCRIPTION "Associated signalling cross-connect Backplane Connection ID." ::= { aprisaXEFXOPortControlTableEntry 8 } aprisaXEFXOInputLevel OBJECT-TYPE SYNTAX AprisaXEFXOInputLevel MAX-ACCESS read-write STATUS current DESCRIPTION "Input Level -10.0 dBr to +1.0 dBr in half dB steps." ::= { aprisaXEFXOPortControlTableEntry 9 } aprisaXEFXOOutputLevel OBJECT-TYPE SYNTAX AprisaXEFXOOutputLevel MAX-ACCESS read-write STATUS current DESCRIPTION "Output Level -10.0 dBr to +1.0 dBr in 0.5 dB steps." ::= { aprisaXEFXOPortControlTableEntry 10 } -- -- end of table -- aprisaXEFXOControlTable OBJECT-TYPE SYNTAX SEQUENCE OF AprisaXEFXOControlTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Control table for FXO." ::= { aprisaXEObjects 140 } aprisaXEFXOControlTableEntry OBJECT-TYPE SYNTAX AprisaXEFXOControlTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries for FXO table." INDEX { aprisaXEFXOControlSlotIndex } ::= { aprisaXEFXOControlTable 1 } AprisaXEFXOControlTableEntry ::= SEQUENCE { aprisaXEFXOControlSlotIndex INTEGER, aprisaXEFXOSPMBandwidth INTEGER, aprisaXEFXOSPMFrequency INTEGER, aprisaXEFXOSPMLevel INTEGER, aprisaXEFXOCasMode INTEGER, aprisaXEFXOCasSignal INTEGER, aprisaXEFXOPCMLaw INTEGER, aprisaXEFXOOnHookSpeed INTEGER, aprisaXEFXORingerImpedance INTEGER, aprisaXEFXORingerThreshold INTEGER, aprisaXEFXOLoopCurrentLimit INTEGER, aprisaXEFXOMinLoopCurrent INTEGER, aprisaXEFXOTipRingVoltage INTEGER, aprisaXEFXOLineImpedance INTEGER, aprisaXEFXOLineReversal INTEGER, aprisaXEFXOABitFault INTEGER, aprisaXEFXOBBitRing INTEGER, aprisaXEFXOCBitBilling INTEGER, aprisaXEFXODBitReversals INTEGER, aprisaXEFXOEchoCanceller INTEGER, aprisaXEFXOABitOffHook INTEGER } aprisaXEFXOControlSlotIndex OBJECT-TYPE SYNTAX AprisaXESlotNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Slot index for FXO Control table." ::= { aprisaXEFXOControlTableEntry 1 } aprisaXEFXOSPMBandwidth OBJECT-TYPE SYNTAX INTEGER { perc15 (0), perc35 (1), perc55 (2), perc75 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the spm detector bandwidth to 1.5%, 3.5%, 5.5% or 7.5%." ::= { aprisaXEFXOControlTableEntry 2 } aprisaXEFXOSPMFrequency OBJECT-TYPE SYNTAX INTEGER { khz12 (0), khz16 (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the spm detector frequency to 12kHz or 16kHz." ::= { aprisaXEFXOControlTableEntry 3 } aprisaXEFXOSPMLevel OBJECT-TYPE SYNTAX AprisaXEFXSPMLevel MAX-ACCESS read-write STATUS current DESCRIPTION "Set the spm detector level 0 to 27 dB." ::= { aprisaXEFXOControlTableEntry 4 } aprisaXEFXOCasMode OBJECT-TYPE SYNTAX INTEGER { casxe (0), casse (1), cas4w (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the CAS mode to XE,SE or 4Wire compatible." ::= { aprisaXEFXOControlTableEntry 5 } aprisaXEFXOCasSignal OBJECT-TYPE SYNTAX AprisaXESignalState MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Set the CAS signal to normal or invert." ::= { aprisaXEFXOControlTableEntry 6 } aprisaXEFXOPCMLaw OBJECT-TYPE SYNTAX AprisaXEPcmLaw MAX-ACCESS read-write STATUS current DESCRIPTION "Set the PCM law to A-law or u-law." ::= { aprisaXEFXOControlTableEntry 7 } aprisaXEFXOOnHookSpeed OBJECT-TYPE SYNTAX INTEGER { ohsFast (0), ohsMedium (1), ohsSlow (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the on hook speed to fast, medium or slow." ::= { aprisaXEFXOControlTableEntry 8 } aprisaXEFXORingerImpedance OBJECT-TYPE SYNTAX INTEGER { rzHigh (0), rxSynthesized (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the ringer impedance to high or synthesized." ::= { aprisaXEFXOControlTableEntry 9 } aprisaXEFXORingerThreshold OBJECT-TYPE SYNTAX INTEGER { rtLow (0), rtMedium (1), rtHigh (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the ringer threshold to low, medium or high." ::= { aprisaXEFXOControlTableEntry 10 } aprisaXEFXOLoopCurrentLimit OBJECT-TYPE SYNTAX INTEGER { ilimOff (0), ilimOn (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the loop current limiter to off or on." ::= { aprisaXEFXOControlTableEntry 11 } aprisaXEFXOMinLoopCurrent OBJECT-TYPE SYNTAX INTEGER { miniLow (0), miniMedium (1), miniHigh (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the min loop current to low, medium or high." ::= { aprisaXEFXOControlTableEntry 12 } aprisaXEFXOTipRingVoltage OBJECT-TYPE SYNTAX INTEGER { dcvLow (0), dcvMedium (1), dcvHigh (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the tip ring voltage to low, medium or high." ::= { aprisaXEFXOControlTableEntry 13 } aprisaXEFXOLineImpedance OBJECT-TYPE SYNTAX INTEGER { acim0 (0), acim1 (1), acim11 (2), acim13 (3), acim3 (4), acim2 (5), acim4 (6), acim9 (7), acim10 (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the line impedance to 600 Ohms, 900 Ohms, 600 Ohms + 2.16 uF, 900 Ohms + 2.16 uF, TN12 - 220 Ohms + (820 Ohms || 120 nF), TBR21 - 270 Ohms + (750 Ohms || 150 nF), BT3 - 370 Ohms + (620 Ohms || 310 nF), BT Network - 320 Ohms + (1050 Ohms || 210 nF), China - 200 Ohms + (680 Ohms || 100 nF)" ::= { aprisaXEFXOControlTableEntry 14 } aprisaXEFXOLineReversal OBJECT-TYPE SYNTAX INTEGER { fxoLineRevOn (0), fxoLineRevOff (1) } MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Set the line reversal on/off." ::= { aprisaXEFXOControlTableEntry 15 } aprisaXEFXOABitFault OBJECT-TYPE SYNTAX AprisaXE2WireSignalState MAX-ACCESS read-write STATUS current DESCRIPTION "Set the CAS A fault bit to Transparent Normal, Transparent Inverted, Forced Normal or Forced Inverted." ::= { aprisaXEFXOControlTableEntry 16 } aprisaXEFXOBBitRing OBJECT-TYPE SYNTAX AprisaXE2WireSignalState MAX-ACCESS read-write STATUS current DESCRIPTION "Set the CAS B ring bit to Transparent Normal, Transparent Inverted, Forced Normal or Forced Inverted." ::= { aprisaXEFXOControlTableEntry 17 } aprisaXEFXOCBitBilling OBJECT-TYPE SYNTAX AprisaXE2WireSignalState MAX-ACCESS read-write STATUS current DESCRIPTION "Set the CAS C billing bit to Transparent Normal, Transparent Inverted, Forced Normal or Forced Inverted." ::= { aprisaXEFXOControlTableEntry 18 } aprisaXEFXODBitReversals OBJECT-TYPE SYNTAX AprisaXE2WireSignalState MAX-ACCESS read-write STATUS current DESCRIPTION "Set the CAS D reversals bit to Transparent Normal, Transparent Inverted, Forced Normal or Forced Inverted." ::= { aprisaXEFXOControlTableEntry 19 } aprisaXEFXOEchoCanceller OBJECT-TYPE SYNTAX INTEGER { fxoEchoCancellerOff (0), fxoEchoCancellerOn (1), fxoEchoCancellerAutoG164 (2), fxoEchoCancellerAutoG165 (3), fxoEchoCancellerReserved1 (4), fxoEchoCancellerReserved2 (5), fxoEchoCancellerReserved3 (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the echo canceller to off, on or auto. The reserved values are for internal use only and cannot be set via SNMP." ::= { aprisaXEFXOControlTableEntry 20 } aprisaXEFXOABitOffHook OBJECT-TYPE SYNTAX AprisaXE2WireSignalState MAX-ACCESS read-write STATUS current DESCRIPTION "Set the CAS A off hook bit to Transparent Normal, Transparent Inverted, Forced Normal or Forced Inverted." ::= { aprisaXEFXOControlTableEntry 21 } -- *************************************************************************** -- End FXO -- *************************************************************************** -- *************************************************************************** -- Backplane Connections -- *************************************************************************** aprisaXEBackplaneConnectionTable OBJECT-TYPE SYNTAX SEQUENCE OF AprisaXEBackplaneConnectionTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of AprisaXE Cross connections." ::= { aprisaXEObjects 150 } aprisaXEBackplaneConnectionTableEntry OBJECT-TYPE SYNTAX AprisaXEBackplaneConnectionTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table entries define a circuit carried ove a TDM bus." INDEX { aprisaXEBackplaneConnectionID } ::= { aprisaXEBackplaneConnectionTable 1 } AprisaXEBackplaneConnectionTableEntry ::= SEQUENCE { aprisaXEBackplaneConnectionID INTEGER, aprisaXEBackplaneTdmBus INTEGER, aprisaXEBackplaneStartBitPos INTEGER, aprisaXEBackplaneLength INTEGER, aprisaXEBackplaneInterface INTEGER } aprisaXEBackplaneConnectionID OBJECT-TYPE SYNTAX AprisaXEConnectionID MAX-ACCESS read-write STATUS current DESCRIPTION "Handle to associate circuits with backplane connections." ::= { aprisaXEBackplaneConnectionTableEntry 1 } aprisaXEBackplaneTdmBus OBJECT-TYPE SYNTAX AprisaXETdmBus MAX-ACCESS read-write STATUS current DESCRIPTION "TDM Bus to switch: busA - busD." ::= { aprisaXEBackplaneConnectionTableEntry 2 } aprisaXEBackplaneStartBitPos OBJECT-TYPE SYNTAX INTEGER (0..2047) MAX-ACCESS read-write STATUS current DESCRIPTION "Start bit position on the associated TDM bus (0 - 2047)." DEFVAL { 0 } ::= { aprisaXEBackplaneConnectionTableEntry 3 } aprisaXEBackplaneLength OBJECT-TYPE SYNTAX INTEGER (0..2047) MAX-ACCESS read-write STATUS current DESCRIPTION "Number of bits to place on the backplane TDM bus (0 - 2047)." DEFVAL { 0 } ::= { aprisaXEBackplaneConnectionTableEntry 4 } aprisaXEBackplaneInterface OBJECT-TYPE SYNTAX AprisaXEInterfaceCnxnType MAX-ACCESS read-write STATUS current DESCRIPTION "The type of circuit this backplane connection is carrying." ::= { aprisaXEBackplaneConnectionTableEntry 5 } aprisaXEBackplaneControl OBJECT IDENTIFIER ::= { aprisaXEObjects 180 } aprisaXEBackplaneControlConnectionID OBJECT-TYPE SYNTAX AprisaXEConnectionID MAX-ACCESS read-write STATUS current DESCRIPTION "The Backplane Connection ID to add or delete." ::= { aprisaXEBackplaneControl 1 } aprisaXEBackplaneControlTdmBus OBJECT-TYPE SYNTAX AprisaXETdmBus MAX-ACCESS read-write STATUS current DESCRIPTION "TDM Bus to switch: busA - busD." ::= { aprisaXEBackplaneControl 2 } aprisaXEBackplaneControlStartBitPos OBJECT-TYPE SYNTAX INTEGER (0..2047) MAX-ACCESS read-write STATUS current DESCRIPTION "Start bit position on the associated TDM bus (0 - 2047)." DEFVAL { 0 } ::= { aprisaXEBackplaneControl 3 } aprisaXEBackplaneControlLength OBJECT-TYPE SYNTAX INTEGER (0..2048) MAX-ACCESS read-write STATUS current DESCRIPTION "Number of bits to place on the backplane TDM bus (0 - 2048)." DEFVAL { 0 } ::= { aprisaXEBackplaneControl 4 } aprisaXEBackplaneControlInterface OBJECT-TYPE SYNTAX AprisaXEInterfaceCnxnType MAX-ACCESS read-write STATUS current DESCRIPTION "The type of circuit this backplane connection is carrying." ::= { aprisaXEBackplaneControl 5 } aprisaXEBackplaneControlCommand OBJECT-TYPE SYNTAX INTEGER { noCommand (0), addCommand (1), deleteCommand (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Command to send to act upon rows in the Backplane Connection table." ::= { aprisaXEBackplaneControl 6 } -- *************************************************************************** -- End Backplane Connections -- *************************************************************************** -- *************************************************************************** -- Aggregate Connections -- *************************************************************************** aprisaXEAggregateConnectionTable OBJECT-TYPE SYNTAX SEQUENCE OF AprisaXEAggregateConnectionTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of Aggregated backplane connections used for interfaces with further cross-connection capability." ::= { aprisaXEObjects 160 } aprisaXEAggregateConnectionTableEntry OBJECT-TYPE SYNTAX AprisaXEAggregateConnectionTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { aprisaXEAggregateBackplaneID, aprisaXEAggregateInterfaceID, aprisaXEAggregateStartBitPos } ::= { aprisaXEAggregateConnectionTable 1 } AprisaXEAggregateConnectionTableEntry ::= SEQUENCE { aprisaXEAggregateBackplaneID Integer32, aprisaXEAggregateInterfaceID Integer32, aprisaXEAggregateStartBitPos INTEGER, aprisaXEAggregateLength INTEGER, aprisaXEAggregateOffset INTEGER, aprisaXEAggregateE1Port INTEGER } aprisaXEAggregateBackplaneID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Backplane Connection identifier." ::= { aprisaXEAggregateConnectionTableEntry 1 } aprisaXEAggregateInterfaceID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { aprisaXEAggregateConnectionTableEntry 2 } aprisaXEAggregateStartBitPos OBJECT-TYPE SYNTAX INTEGER (0..2047) MAX-ACCESS read-only STATUS current DESCRIPTION "Start bit position of the data coming into the cross-connection device (SWITI) for this interface connection." ::= { aprisaXEAggregateConnectionTableEntry 3 } aprisaXEAggregateLength OBJECT-TYPE SYNTAX INTEGER (0..2047) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of bits required for this interface connection." ::= { aprisaXEAggregateConnectionTableEntry 4 } aprisaXEAggregateOffset OBJECT-TYPE SYNTAX INTEGER (0..2047) MAX-ACCESS read-only STATUS current DESCRIPTION "Offset into the aggregate connection where this interface connection is placed." ::= { aprisaXEAggregateConnectionTableEntry 5 } aprisaXEAggregateE1Port OBJECT-TYPE SYNTAX AprisaXEPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Port number associated with this connection." ::= { aprisaXEAggregateConnectionTableEntry 6 } aprisaXEAggregateControl OBJECT IDENTIFIER ::= { aprisaXEObjects 170 } aprisaXEAggregateControlBackplaneID OBJECT-TYPE SYNTAX INTEGER (0..2047) MAX-ACCESS read-write STATUS current DESCRIPTION "The backplane ID to add or delete." ::= { aprisaXEAggregateControl 1 } aprisaXEAggregateControlInterfaceID OBJECT-TYPE SYNTAX INTEGER (0..2047) MAX-ACCESS read-write STATUS current DESCRIPTION "Aggregate connection identifier." ::= { aprisaXEAggregateControl 2 } aprisaXEAggregateControlStartBitPos OBJECT-TYPE SYNTAX INTEGER (0..2047) MAX-ACCESS read-write STATUS current DESCRIPTION "Start bit position of the data coming into the cross-connection device (SWITI) for this interface connection." ::= { aprisaXEAggregateControl 3 } aprisaXEAggregateControlLength OBJECT-TYPE SYNTAX INTEGER (0..2047) MAX-ACCESS read-write STATUS current DESCRIPTION "Number of bits required for this interface connection." ::= { aprisaXEAggregateControl 4 } aprisaXEAggregateControlOffset OBJECT-TYPE SYNTAX INTEGER (0..2047) MAX-ACCESS read-write STATUS current DESCRIPTION "Offset into the aggregate connection where this interface connection is placed." ::= { aprisaXEAggregateControl 5 } aprisaXEAggregateControlCommand OBJECT-TYPE SYNTAX INTEGER { noCommand (0), addCommand (1), deleteCommand (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Command to send to act upon the rows in the Aggregate Connection table." ::= { aprisaXEAggregateControl 6 } -- *************************************************************************** -- End Aggregate Connections -- *************************************************************************** -- *************************************************************************** -- Cross Connect Control -- *************************************************************************** aprisaXECrossConnectControl OBJECT IDENTIFIER ::= { aprisaXEObjects 200 } aprisaXECrossConnectControlCommand OBJECT-TYPE SYNTAX INTEGER { noCommand (0), deleteCommand (1), activateCommand (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Command to send to delete all current cross-connections or to activate a new set of cross-connections." ::= { aprisaXECrossConnectControl 1 } aprisaXEMotherboardExtendedModeCapable OBJECT-TYPE SYNTAX INTEGER { extModeNo (0), extModeYes (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Allows the cross connect application to determine whether to stripe cross connections or not." ::= { aprisaXECrossConnectControl 2 } aprisaXEEthernetActivationStatus OBJECT-TYPE SYNTAX AprisaXECCActivationStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Ethernet activation status i.e activated, failed or currently busy activating." ::= { aprisaXECrossConnectControl 3 } -- *************************************************************************** -- End Cross Connect Control -- *************************************************************************** -- *************************************************************************** -- Cross Connect Activation Status Table -- *************************************************************************** aprisaXECCActivationStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AprisaXECCActivationStatusTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "CC Activation status table." ::= { aprisaXEObjects 202 } aprisaXECCActivationStatusTableEntry OBJECT-TYPE SYNTAX AprisaXECCActivationStatusTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries for CC Activation status table." INDEX { aprisaXECCActivationStatusSlotIndex } ::= { aprisaXECCActivationStatusTable 1 } AprisaXECCActivationStatusTableEntry ::= SEQUENCE { aprisaXECCActivationStatusSlotIndex INTEGER, aprisaXECCActivationStatus INTEGER } aprisaXECCActivationStatusSlotIndex OBJECT-TYPE SYNTAX AprisaXESlotNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Slot index for CC Activation Status table." ::= { aprisaXECCActivationStatusTableEntry 1 } aprisaXECCActivationStatus OBJECT-TYPE SYNTAX AprisaXECCActivationStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Cross-connect activation status i.e activated, failed or currently busy activating." ::= { aprisaXECCActivationStatusTableEntry 2 } -- *************************************************************************** -- End Cross Connect Activation Status Table -- *************************************************************************** -- *************************************************************************** -- FXS -- *************************************************************************** aprisaXEFXSPortControlTable OBJECT-TYPE SYNTAX SEQUENCE OF AprisaXEFXSPortControlTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port Control table for FXS." ::= { aprisaXEObjects 190 } aprisaXEFXSPortControlTableEntry OBJECT-TYPE SYNTAX AprisaXEFXSPortControlTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries for FXS table." INDEX { aprisaXEFXSPortControlSlotIndex, aprisaXEFXSPortIndex } ::= { aprisaXEFXSPortControlTable 1 } AprisaXEFXSPortControlTableEntry ::= SEQUENCE { aprisaXEFXSPortControlSlotIndex INTEGER, aprisaXEFXSPortIndex INTEGER, aprisaXEFXSLoopback INTEGER, aprisaXEFXSAdpcmCompression INTEGER, aprisaXEFXSRxGain INTEGER, aprisaXEFXSTxGain INTEGER, aprisaXEFXSConnectionID INTEGER, aprisaXEFXSSignallingConnectionID INTEGER, aprisaXEFXSInputLevel INTEGER, aprisaXEFXSOutputLevel INTEGER, aprisaXEFXSPathMute INTEGER } aprisaXEFXSPortControlSlotIndex OBJECT-TYPE SYNTAX AprisaXESlotNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Slot index for FXS Control table." ::= { aprisaXEFXSPortControlTableEntry 1 } aprisaXEFXSPortIndex OBJECT-TYPE SYNTAX AprisaXEPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Port index for FXS Control table." ::= { aprisaXEFXSPortControlTableEntry 2 } aprisaXEFXSLoopback OBJECT-TYPE SYNTAX FourRFLoopback MAX-ACCESS read-write STATUS current DESCRIPTION "Loopback control on or off for ports." ::= { aprisaXEFXSPortControlTableEntry 3 } aprisaXEFXSAdpcmCompression OBJECT-TYPE SYNTAX AprisaXEAdpcmCompression MAX-ACCESS read-write STATUS current DESCRIPTION "ADPCM compression 16, 24, 32, 64 kbps or none." DEFVAL { none } ::= { aprisaXEFXSPortControlTableEntry 4 } aprisaXEFXSRxGain OBJECT-TYPE SYNTAX INTEGER { fxsrxpos30 (0), fxsrxpos25 (1), fxsrxpos20 (2), fxsrxpos15 (3), fxsrxpos10 (4), fxsrxpos05 (5), fxsrxpos0 (6), fxsrxneg05 (7), fxsrxneg10 (8), fxsrxneg15 (9), fxsrxneg20 (10), fxsrxneg25 (11), fxsrxneg30 (12), fxsrxneg35 (13), fxsrxneg40 (14), fxsrxneg45 (15), fxsrxneg50 (16), fxsrxneg55 (17), fxsrxneg60 (18), fxsrxneg65 (19), fxsrxneg70 (20), fxsrxneg75 (21), fxsrxneg80 (22), fxsrxneg85 (23), fxsrxneg90 (24), fxsrxneg95 (25) } MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Rx gain -9.5 dB to +3 dB in 0.5 dB steps." ::= { aprisaXEFXSPortControlTableEntry 5 } aprisaXEFXSTxGain OBJECT-TYPE SYNTAX INTEGER { fxstxpos95 (0), fxstxpos90 (1), fxstxpos85 (2), fxstxpos80 (3), fxstxpos75 (4), fxstxpos70 (5), fxstxpos65 (6), fxstxpos60 (7), fxstxpos55 (8), fxstxpos50 (9), fxstxpos45 (10), fxstxpos40 (11), fxstxpos35 (12), fxstxpos30 (13), fxstxpos25 (14), fxstxpos20 (15), fxstxpos15 (16), fxstxpos10 (17), fxstxpos05 (18), fxstxpos0 (19), fxstxneg05 (20), fxstxneg10 (21), fxstxneg15 (22), fxstxneg20 (23), fxstxneg25 (24), fxstxneg30 (25) } MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Tx gain -3 dB to 9.5 dB in 0.5 dB steps." ::= { aprisaXEFXSPortControlTableEntry 6 } aprisaXEFXSConnectionID OBJECT-TYPE SYNTAX AprisaXEConnectionID MAX-ACCESS read-write STATUS current DESCRIPTION "Associated cross-connect Backplane Connection ID." ::= { aprisaXEFXSPortControlTableEntry 7 } aprisaXEFXSSignallingConnectionID OBJECT-TYPE SYNTAX AprisaXEConnectionID MAX-ACCESS read-write STATUS current DESCRIPTION "Associated signalling cross-connect Backplane Connection ID." ::= { aprisaXEFXSPortControlTableEntry 8 } aprisaXEFXSInputLevel OBJECT-TYPE SYNTAX AprisaXEFXSInputLevel MAX-ACCESS read-write STATUS current DESCRIPTION "Input Level -9.0 dBr to +3.0 dBr in half dB steps." ::= { aprisaXEFXSPortControlTableEntry 9 } aprisaXEFXSOutputLevel OBJECT-TYPE SYNTAX AprisaXEFXSOutputLevel MAX-ACCESS read-write STATUS current DESCRIPTION "Output Level -9.5 dBr to +2.5 dBr in 0.5 dB steps." ::= { aprisaXEFXSPortControlTableEntry 10 } aprisaXEFXSPathMute OBJECT-TYPE SYNTAX AprisaXEFXSPathMute MAX-ACCESS read-write STATUS current DESCRIPTION "Applies DFXS Mute Function - No Mute, Mute Rx or Mute Tx." ::= { aprisaXEFXSPortControlTableEntry 11 } -- -- end of table -- aprisaXEFXSControlTable OBJECT-TYPE SYNTAX SEQUENCE OF AprisaXEFXSControlTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Control table for FXS." ::= { aprisaXEObjects 195 } aprisaXEFXSControlTableEntry OBJECT-TYPE SYNTAX AprisaXEFXSControlTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries for FXS table." INDEX { aprisaXEFXSControlSlotIndex } ::= { aprisaXEFXSControlTable 1 } AprisaXEFXSControlTableEntry ::= SEQUENCE { aprisaXEFXSControlSlotIndex INTEGER, aprisaXEFXSPCMLaw INTEGER, aprisaXEFXSEchoCanceller INTEGER, aprisaXEFXSBillingToneFrequency INTEGER, aprisaXEFXSBillingToneAmplitude INTEGER, aprisaXEFXSBillingToneDecay INTEGER, aprisaXEFXSRingerFrequency INTEGER, aprisaXEFXSRingerAmplitude INTEGER, aprisaXEFXSLineImpedance INTEGER, aprisaXEFXSCasMode INTEGER, aprisaXEFXSCasSignal INTEGER, aprisaXEFXSTransHybridBalance INTEGER, aprisaXEFXSLineReversal INTEGER, aprisaXEFXSCalibrate INTEGER, aprisaXEFXSABitFault INTEGER, aprisaXEFXSBBitRing INTEGER, aprisaXEFXSCBitBilling INTEGER, aprisaXEFXSDBitReversals INTEGER, aprisaXEFXSLoopParameters INTEGER, aprisaXEFXSABitOffHook INTEGER } aprisaXEFXSControlSlotIndex OBJECT-TYPE SYNTAX AprisaXESlotNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Slot index for FXS Control table." ::= { aprisaXEFXSControlTableEntry 1 } aprisaXEFXSPCMLaw OBJECT-TYPE SYNTAX AprisaXEPcmLaw MAX-ACCESS read-write STATUS current DESCRIPTION "Set the PCM law to A-law or u-law." ::= { aprisaXEFXSControlTableEntry 2 } aprisaXEFXSEchoCanceller OBJECT-TYPE SYNTAX INTEGER { echoCancellerOff (0), echoCancellerOn (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the echo canceller to on or off." ::= { aprisaXEFXSControlTableEntry 3 } aprisaXEFXSBillingToneFrequency OBJECT-TYPE SYNTAX INTEGER { khz12 (0), khz16 (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the billing tone generator frequency to 12kHz or 16kHz." ::= { aprisaXEFXSControlTableEntry 4 } aprisaXEFXSBillingToneAmplitude OBJECT-TYPE SYNTAX INTEGER { mv400 (6), mv300 (0), mv250 (1), mv200 (2), mv150 (3), mv100 (4), mv50 (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the billing tone generator amplitude to 400mV, 300mV, 250mV, 200mV, 150mV, 100mV or 50mV. Note, that software release 7.3.x only supports 400mV, 300mV, 200mV and 100mV." ::= { aprisaXEFXSControlTableEntry 5 } aprisaXEFXSBillingToneDecay OBJECT-TYPE SYNTAX INTEGER { ms02 (0), ms05 (1), ms1 (2), ms2 (3), ms5 (4), ms10 (5), ms20 (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the billing tone generator attack decay ramp to 0.2ms, 0.5ms, 1ms, 2ms, 5ms, 10ms or 20ms." ::= { aprisaXEFXSControlTableEntry 6 } aprisaXEFXSRingerFrequency OBJECT-TYPE SYNTAX INTEGER { hz17 (0), hz25 (1), hz50 (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the ringer frequency to 17Hz, 25Hz or 50Hz." ::= { aprisaXEFXSControlTableEntry 7 } aprisaXEFXSRingerAmplitude OBJECT-TYPE SYNTAX INTEGER { vrms40 (0), vrms45 (1), vrms50 (2), vrms55 (3), vrms60 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the ringer amplitude to 40 V RMS, 45 V RMS, 50 V RMS, 55 V RMS or 60 V RMS." ::= { aprisaXEFXSControlTableEntry 8 } aprisaXEFXSLineImpedance OBJECT-TYPE SYNTAX INTEGER { lineImpd1 (0), lineImpd2 (1), lineImpd3 (2), lineImpd4 (3), lineImpd5 (4), lineImpd6 (5), lineImpd7 (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the subscriber line impedance to 600 Ohms, 900 Ohms, 600 Ohms + 2.16 uF, 900 Ohms + 2.16 uF, TN12 - 220 Ohms + (820 Ohms || 120 nF), TBR21 - 270 Ohms + (750 Ohms || 150 nF), BT3 - 370 Ohms + (620 Ohms || 310 nF)" ::= { aprisaXEFXSControlTableEntry 9 } aprisaXEFXSCasMode OBJECT-TYPE SYNTAX INTEGER { casxe (0), casse (1), cas4w (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the CAS mode to XE,SE or 4Wire compatible." ::= { aprisaXEFXSControlTableEntry 10 } aprisaXEFXSCasSignal OBJECT-TYPE SYNTAX AprisaXESignalState MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Set the CAS signal to normal or invert." ::= { aprisaXEFXSControlTableEntry 11 } aprisaXEFXSTransHybridBalance OBJECT-TYPE SYNTAX INTEGER { transHybridBal1 (0), transHybridBal2 (1), transHybridBal3 (2), transHybridBal4 (3), transHybridBal5 (4), transHybridBal6 (5), transHybridBal7 (6), transHybridBal8 (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the trans hybrid balance to 4.08dB, 2.5dB, 1.16dB, 0dB, -1.02dB, -1.94dB, -2.77dB, Off" ::= { aprisaXEFXSControlTableEntry 12 } aprisaXEFXSLineReversal OBJECT-TYPE SYNTAX INTEGER { fxsLineRevOn (0), fxsLineRevOff (1) } MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Set the line reversal on/off." ::= { aprisaXEFXSControlTableEntry 13 } aprisaXEFXSCalibrate OBJECT-TYPE SYNTAX INTEGER { fxsCalibrateNo (0), fxsCalibrateYes (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Recalibrate the card yes/no." ::= { aprisaXEFXSControlTableEntry 14 } aprisaXEFXSABitFault OBJECT-TYPE SYNTAX AprisaXE2WireSignalState MAX-ACCESS read-write STATUS current DESCRIPTION "Set the CAS A fault bit to Transparent Normal, Transparent Inverted, Forced Normal or Forced Inverted." ::= { aprisaXEFXSControlTableEntry 15 } aprisaXEFXSBBitRing OBJECT-TYPE SYNTAX AprisaXE2WireSignalState MAX-ACCESS read-write STATUS current DESCRIPTION "Set the CAS B ring bit to Transparent Normal, Transparent Inverted, Forced Normal or Forced Inverted." ::= { aprisaXEFXSControlTableEntry 16 } aprisaXEFXSCBitBilling OBJECT-TYPE SYNTAX AprisaXE2WireSignalState MAX-ACCESS read-write STATUS current DESCRIPTION "Set the CAS C billing bit to Transparent Normal, Transparent Inverted, Forced Normal or Forced Inverted." ::= { aprisaXEFXSControlTableEntry 17 } aprisaXEFXSDBitReversals OBJECT-TYPE SYNTAX AprisaXE2WireSignalState MAX-ACCESS read-write STATUS current DESCRIPTION "Set the CAS D reversals bit to Transparent Normal, Transparent Inverted, Forced Normal or Forced Inverted." ::= { aprisaXEFXSControlTableEntry 18 } aprisaXEFXSLoopParameters OBJECT-TYPE SYNTAX INTEGER { fxsLoopParamDefault (0), fxsLoopParamTelkomSA (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the loop parameters to 'default' or 'Telkom SA Limited'." ::= { aprisaXEFXSControlTableEntry 19 } aprisaXEFXSABitOffHook OBJECT-TYPE SYNTAX AprisaXE2WireSignalState MAX-ACCESS read-write STATUS current DESCRIPTION "Set the CAS A off hook bit to Transparent Normal, Transparent Inverted, Forced Normal or Forced Inverted." ::= { aprisaXEFXSControlTableEntry 20 } -- *************************************************************************** -- End FXS -- *************************************************************************** -- *************************************************************************** -- HSS -- *************************************************************************** aprisaXEHSSControlTable OBJECT-TYPE SYNTAX SEQUENCE OF AprisaXEHSSControlTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Control table for HSS." ::= { aprisaXEObjects 207 } aprisaXEHSSControlTableEntry OBJECT-TYPE SYNTAX AprisaXEHSSControlTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries for HSS table." INDEX { aprisaXEHSSControlSlotIndex } ::= { aprisaXEHSSControlTable 1 } AprisaXEHSSControlTableEntry ::= SEQUENCE { aprisaXEHSSControlSlotIndex INTEGER, aprisaXEHSSConnectionID INTEGER, aprisaXEHSSSignallingID INTEGER, aprisaXEHSSEquipmentMode INTEGER, aprisaXEHSSLoopback INTEGER, aprisaXEHSSNetworkClockSource INTEGER, aprisaXEHSSSerialBaudRate INTEGER, aprisaXEHSSV110BaudRate INTEGER, aprisaXEHSSSendHandshakingMode INTEGER, aprisaXEHSSDataReadyMode INTEGER, aprisaXEHSSCarrierDetectMode INTEGER, aprisaXEHSSClockSelection INTEGER, aprisaXEHSSXTxCEnabled INTEGER, aprisaXEHSSSerialMode INTEGER } aprisaXEHSSControlSlotIndex OBJECT-TYPE SYNTAX AprisaXESlotNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Slot index for HSS Control Table." ::= { aprisaXEHSSControlTableEntry 1 } aprisaXEHSSConnectionID OBJECT-TYPE SYNTAX AprisaXEConnectionID MAX-ACCESS read-write STATUS current DESCRIPTION "Backplane Connection ID for data connection." ::= { aprisaXEHSSControlTableEntry 2 } aprisaXEHSSSignallingID OBJECT-TYPE SYNTAX AprisaXEConnectionID MAX-ACCESS read-write STATUS current DESCRIPTION "Backplane connection ID for signalling/control connection." ::= { aprisaXEHSSControlTableEntry 3 } aprisaXEHSSEquipmentMode OBJECT-TYPE SYNTAX AprisaXESerialEquipmentMode MAX-ACCESS read-only STATUS current DESCRIPTION "Terminal Equipment mode, DCE or DTE, this is a direct reflection of the equipment mode based on the type of cable currently connected. The value is not defined if no cable is attached." ::= { aprisaXEHSSControlTableEntry 4 } aprisaXEHSSLoopback OBJECT-TYPE SYNTAX FourRFLoopback MAX-ACCESS read-write STATUS current DESCRIPTION "Interface loopback control." DEFVAL { 0 } ::= { aprisaXEHSSControlTableEntry 5 } aprisaXEHSSNetworkClockSource OBJECT-TYPE SYNTAX FourRFNetworkClockSelect MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the port drive the clock source or not." ::= { aprisaXEHSSControlTableEntry 6 } aprisaXEHSSSerialBaudRate OBJECT-TYPE SYNTAX INTEGER (1..256) MAX-ACCESS read-write STATUS current DESCRIPTION "Serial Baud rate where 1 = 8kbps and 256 = 2Mbps." ::= { aprisaXEHSSControlTableEntry 7 } aprisaXEHSSV110BaudRate OBJECT-TYPE SYNTAX INTEGER { v110-600 (0), v110-1200 (1), v110-2400 (2), v110-4800 (3), v110-7200 (4), v110-9600 (5), v110-12000 (6), v110-14400 (7), v110-19200 (8), v110-24000 (9), v110-28800 (10), v110-38400 (11) } MAX-ACCESS read-write STATUS current DESCRIPTION "V110 baud rate." ::= { aprisaXEHSSControlTableEntry 8 } aprisaXEHSSSendHandshakingMode OBJECT-TYPE SYNTAX INTEGER { rts-ctsOff (0), rts-ctsOn (1), rts-ctsCarrier (2), rts-ctsCarrierRemote (3), rts-ctsCarrierLocalDCD (4), rts-ctsCarrierLocalRTS (5), rts-ctsCarrierLocalRTS1ms (6), rts-ctsCarrierLocalRTS24ms (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Select 1 of 8 RTS/CTS modes of operation." ::= { aprisaXEHSSControlTableEntry 9 } aprisaXEHSSDataReadyMode OBJECT-TYPE SYNTAX INTEGER { dsr-dtrOff (0), dsr-dtrOn (1), dsr-dtrCarrier (2), dsr-dtrCarrierRemote (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Select 1 of 8 DSR/DTR modes." ::= { aprisaXEHSSControlTableEntry 10 } aprisaXEHSSCarrierDetectMode OBJECT-TYPE SYNTAX INTEGER { dcdOff (0), dcdOn (1), dcdCarrierRemoteDCD (2), dcdCarrierLocalDTR (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Select 1 of 4 DCD modes." ::= { aprisaXEHSSControlTableEntry 11 } aprisaXEHSSClockSelection OBJECT-TYPE SYNTAX INTEGER { hssClockInternal (0), hssClockXTxC (1), hssClockTxC (2), hssClockOverhead (3), hssClockNoOverhead (4), hssClockXTxC-RxC (5), hssClockXTxCNoOverhead (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Select the clock mode internal to the HSS traffic path." ::= { aprisaXEHSSControlTableEntry 12 } aprisaXEHSSXTxCEnabled OBJECT-TYPE SYNTAX INTEGER { hssxTxCEnabled (0), hssxTxCDisabled (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Select whether XTxC generation is enabled or disabled for the port. The default is enabled." ::= { aprisaXEHSSControlTableEntry 13 } aprisaXEHSSSerialMode OBJECT-TYPE SYNTAX AprisaXEHssSerialMode MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the type of serial interface cable is connected to the HSS port." ::= { aprisaXEHSSControlTableEntry 14 } -- *************************************************************************** -- End HSS -- *************************************************************************** -- *************************************************************************** -- V24 -- *************************************************************************** aprisaXEV24PortControlTable OBJECT-TYPE SYNTAX SEQUENCE OF AprisaXEV24PortControlTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port Control table for V24." ::= { aprisaXEObjects 210 } aprisaXEV24PortControlTableEntry OBJECT-TYPE SYNTAX AprisaXEV24PortControlTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries for V24 table." INDEX { aprisaXEV24PortControlSlotIndex, aprisaXEV24PortIndex } ::= { aprisaXEV24PortControlTable 1 } AprisaXEV24PortControlTableEntry ::= SEQUENCE { aprisaXEV24PortControlSlotIndex INTEGER, aprisaXEV24PortIndex INTEGER, aprisaXEV24BaudRate INTEGER, aprisaXEV24Loopback INTEGER, aprisaXEV24DataBits INTEGER, aprisaXEV24StopBits INTEGER, aprisaXEV24ParityBits INTEGER, aprisaXEV24ConnectionID INTEGER } aprisaXEV24PortControlSlotIndex OBJECT-TYPE SYNTAX AprisaXESlotNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Slot index for V24 Control table." ::= { aprisaXEV24PortControlTableEntry 1 } aprisaXEV24PortIndex OBJECT-TYPE SYNTAX AprisaXEPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Port index for V24 Control table." ::= { aprisaXEV24PortControlTableEntry 2 } aprisaXEV24BaudRate OBJECT-TYPE SYNTAX INTEGER { v24-300 (0), v24-600 (1), v24-1200 (2), v24-2400 (3), v24-4800 (4), v24-7200 (5), v24-9600 (6), v24-12800 (7), v24-14400 (8), v24-19200 (9), v24-23040 (10), v24-28800 (11), v24-38400 (12), v24-57600 (13), v24-115200 (14) } MAX-ACCESS read-write STATUS current DESCRIPTION "Baud Rate from 300 baud to 115200 baud." DEFVAL { none } ::= { aprisaXEV24PortControlTableEntry 3 } aprisaXEV24Loopback OBJECT-TYPE SYNTAX FourRFLoopback MAX-ACCESS read-write STATUS current DESCRIPTION "Loopback control on or off for ports." ::= { aprisaXEV24PortControlTableEntry 4 } aprisaXEV24DataBits OBJECT-TYPE SYNTAX INTEGER { databits7 (0), databits8 (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "No of data bits used, 7 or 8." ::= { aprisaXEV24PortControlTableEntry 5 } aprisaXEV24StopBits OBJECT-TYPE SYNTAX INTEGER { stopbits1 (0), stopbits2 (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "No of stop bits used, 1 or 2." ::= { aprisaXEV24PortControlTableEntry 6 } aprisaXEV24ParityBits OBJECT-TYPE SYNTAX INTEGER { paritybits0 (0), paritybits1 (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "No of parity bits used, 0 or 1." ::= { aprisaXEV24PortControlTableEntry 7 } aprisaXEV24ConnectionID OBJECT-TYPE SYNTAX AprisaXEConnectionID MAX-ACCESS read-write STATUS current DESCRIPTION "Associated cross-connect Backplane Connection ID." ::= { aprisaXEV24PortControlTableEntry 8 } -- *************************************************************************** -- End V24 -- *************************************************************************** -- *************************************************************************** -- Upgrade Control -- -- Software upgrade (using TFTP) can be performed by setting the required -- software version string and setting the command OID. This results in a -- file being uploaded from the server release_x_y_z.cfg. This file lists the -- files required for the specified software release. TFTP is then used to -- upload any files not currently installed and the required images are -- activated. -- -- *************************************************************************** aprisaXESoftwareUpgradeControl OBJECT IDENTIFIER ::= { aprisaXEObjects 300 } aprisaXESoftwareUpgradeVersion OBJECT-TYPE SYNTAX DisplayString ( SIZE (0..16) ) MAX-ACCESS read-write STATUS current DESCRIPTION "New software version details of the form x_y_z." ::= { aprisaXESoftwareUpgradeControl 1 } aprisaXESoftwareUpgradeCommand OBJECT-TYPE SYNTAX INTEGER { none (0), upgrade (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Command used to instigate a software upgrade." ::= { aprisaXESoftwareUpgradeControl 2 } aprisaXESoftwareUpgradeResult OBJECT-TYPE SYNTAX FourRFProcessResultType MAX-ACCESS read-only STATUS current DESCRIPTION "Status of a software upgrade, this will have to be polled to follow the upload progress." ::= { aprisaXESoftwareUpgradeControl 3 } aprisaXESoftwareUpgradeControlGroup OBJECT-GROUP OBJECTS { aprisaXESoftwareUpgradeVersion, aprisaXESoftwareUpgradeCommand, aprisaXESoftwareUpgradeResult } STATUS current DESCRIPTION "The Aprisa XE software upgrade group." ::= { aprisaXEGroups 300 } -- *************************************************************************** -- End Upgrade Control -- *************************************************************************** -- *************************************************************************** -- Ethernet Table -- -- A table which maintains the VLAN and QOS configuration of each of -- the User Ethernet Ports -- -- *************************************************************************** aprisaXEEthernetTable OBJECT-TYPE SYNTAX SEQUENCE OF AprisaXEEthernetTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table used to display and configure Ethernet settings." ::= { aprisaXEObjects 97 } aprisaXEEthernetTableEntry OBJECT-TYPE SYNTAX AprisaXEEthernetTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Individual Ethernet port settings." INDEX { aprisaXEEthernetPortNum } ::= { aprisaXEEthernetTable 1 } AprisaXEEthernetTableEntry ::= SEQUENCE { aprisaXEEthernetPortNum INTEGER, aprisaXEEthernetGroup INTEGER, aprisaXEEthernetIngressRate INTEGER, aprisaXEEthernetPortPriority INTEGER } aprisaXEEthernetPortNum OBJECT-TYPE SYNTAX AprisaXEEthernetPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "The port number, there are four ports on the hub." ::= { aprisaXEEthernetTableEntry 1 } aprisaXEEthernetGroup OBJECT-TYPE SYNTAX AprisaXEEthernetGroup MAX-ACCESS read-write STATUS current DESCRIPTION "The Ethernet Group of which this port is a member." ::= { aprisaXEEthernetTableEntry 2 } aprisaXEEthernetIngressRate OBJECT-TYPE SYNTAX AprisaXEEthernetFrameRate MAX-ACCESS read-write STATUS current DESCRIPTION "The ingress frame rate limit for this port." ::= { aprisaXEEthernetTableEntry 3 } aprisaXEEthernetPortPriority OBJECT-TYPE SYNTAX AprisaXEEthernetPortPriority MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the bandwidth allocated to this port." ::= { aprisaXEEthernetTableEntry 4 } -- *************************************************************************** -- Ethernet Settings -- -- The global VLAN and QOS configuration of the Ethernet Switch -- -- *************************************************************************** aprisaXEEthernetVlanQosSettings OBJECT IDENTIFIER ::= { aprisaXEObjects 98 } aprisaXEEthernetGrouping OBJECT-TYPE SYNTAX AprisaXEEthernetGrouping MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether Ethernet grouping (VLANs) is enabled or disabled." ::= { aprisaXEEthernetVlanQosSettings 1 } aprisaXEEthernetManagementGroup OBJECT-TYPE SYNTAX AprisaXEEthernetGroup MAX-ACCESS read-only STATUS current DESCRIPTION "The Ethernet Group for management." ::= { aprisaXEEthernetVlanQosSettings 2 } aprisaXEEthernetPrioQueueScheduling OBJECT-TYPE SYNTAX AprisaXEEthernetPrioQueueScheduling MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates Ethernet priority queue scheduling scheme (either strict or weighted)." ::= { aprisaXEEthernetVlanQosSettings 3 } aprisaXEEthernetPrioQueueMapping OBJECT-TYPE SYNTAX AprisaXEEthernetPrioQueueMapping MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the IEEE 802.1 Ethernet priority queue mapping scheme (either standard or cisco)." ::= { aprisaXEEthernetVlanQosSettings 4 } aprisaXEDefaultEthernetGrouping OBJECT-TYPE SYNTAX AprisaXEDefaultAction MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates when Ethernet Grouping settings must be reset to default values." ::= { aprisaXEEthernetVlanQosSettings 5 } aprisaXEDefaultEthernetQos OBJECT-TYPE SYNTAX AprisaXEDefaultAction MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates when Ethernet Grouping settings must be reset to default values." ::= { aprisaXEEthernetVlanQosSettings 6 } -- *************************************************************************** -- Dual E1 Alarms -- *************************************************************************** aprisaXEDualJetBoardTable OBJECT-TYPE SYNTAX SEQUENCE OF AprisaXEDualJetBoardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of Dual E1 card specific configuration details." ::= { aprisaXEObjects 220 } aprisaXEDualJetBoardEntry OBJECT-TYPE SYNTAX AprisaXEDualJetBoardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Dual E1 configuration details." INDEX { aprisaXEDualJetBoardTableIndex } ::= { aprisaXEDualJetBoardTable 1 } AprisaXEDualJetBoardEntry ::= SEQUENCE { aprisaXEDualJetBoardTableIndex INTEGER } aprisaXEDualJetBoardTableIndex OBJECT-TYPE SYNTAX AprisaXESlotNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Dual E1 board indexed by slot." ::= { aprisaXEDualJetBoardEntry 1 } aprisaXEDualJetPortTable OBJECT-TYPE SYNTAX SEQUENCE OF AprisaXEDualJetPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table based on slot and port of DualJet cards alarms." ::= { aprisaXEObjects 221 } aprisaXEDualJetPortEntry OBJECT-TYPE SYNTAX AprisaXEDualJetPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Dual E1 port alarms." INDEX { aprisaXEDualJetPortTableSlot, aprisaXEDualJetPortTablePort } ::= { aprisaXEDualJetPortTable 1 } AprisaXEDualJetPortEntry ::= SEQUENCE { aprisaXEDualJetPortTableSlot INTEGER, aprisaXEDualJetPortTablePort INTEGER, aprisaXEDualJetAISAlarmStatus INTEGER, aprisaXEDualJetAISAlarmSeverity INTEGER, aprisaXEDualJetAISAlarmEnabled INTEGER, aprisaXEDualJetLOSAlarmStatus INTEGER, aprisaXEDualJetLOSAlarmSeverity INTEGER, aprisaXEDualJetLOSAlarmEnabled INTEGER } aprisaXEDualJetPortTableSlot OBJECT-TYPE SYNTAX AprisaXESlotNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Port table index based on slot number." ::= { aprisaXEDualJetPortEntry 1 } aprisaXEDualJetPortTablePort OBJECT-TYPE SYNTAX AprisaXEPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Port table index based on port number." ::= { aprisaXEDualJetPortEntry 2 } aprisaXEDualJetAISAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "AIS alarm status." ::= { aprisaXEDualJetPortEntry 3 } aprisaXEDualJetAISAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "AIS alarm severity." ::= { aprisaXEDualJetPortEntry 4 } aprisaXEDualJetAISAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "AIS alarm enabled or disabled." ::= { aprisaXEDualJetPortEntry 5 } aprisaXEDualJetLOSAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "LOS alarm status." ::= { aprisaXEDualJetPortEntry 6 } aprisaXEDualJetLOSAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "LOS alarm severity." ::= { aprisaXEDualJetPortEntry 7 } aprisaXEDualJetLOSAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "LOS alarm enabled or disabled." ::= { aprisaXEDualJetPortEntry 8 } aprisaXEDualJetIFConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF AprisaXEDualJetIFConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Switch data table which describes the allocation of user data on to the TDM busses." ::= { aprisaXEObjects 222 } aprisaXEDualJetIFConfigEntry OBJECT-TYPE SYNTAX AprisaXEDualJetIFConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Dual JET config data." INDEX { aprisaXEDualJetIFConfigSlotIndex, aprisaXEDualJetIFConfigPortIndex } ::= { aprisaXEDualJetIFConfigTable 1 } AprisaXEDualJetIFConfigEntry ::= SEQUENCE { aprisaXEDualJetIFConfigSlotIndex INTEGER, aprisaXEDualJetIFConfigPortIndex INTEGER, aprisaXEDualJetTrafficType INTEGER, aprisaXEDualJetLoopback INTEGER, aprisaXEDualJetLineEncoding INTEGER, aprisaXEDualJetPcmMode INTEGER, aprisaXEDualJetClockSource INTEGER, aprisaXEDualJetLineRadioLoopback INTEGER, aprisaXEDualJetTxWaveFormShaper INTEGER } aprisaXEDualJetIFConfigSlotIndex OBJECT-TYPE SYNTAX AprisaXESlotNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Index to the port table based on port number." ::= { aprisaXEDualJetIFConfigEntry 1 } aprisaXEDualJetIFConfigPortIndex OBJECT-TYPE SYNTAX AprisaXEPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Index to the port table based on port number." ::= { aprisaXEDualJetIFConfigEntry 2 } aprisaXEDualJetTrafficType OBJECT-TYPE SYNTAX AprisaXEQuadJetTrafficType MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the traffic type on a Dual JET port." ::= { aprisaXEDualJetIFConfigEntry 3 } aprisaXEDualJetLoopback OBJECT-TYPE SYNTAX FourRFLoopback MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Controls the traffic loopback on a Dual JET port." ::= { aprisaXEDualJetIFConfigEntry 4 } aprisaXEDualJetLineEncoding OBJECT-TYPE SYNTAX AprisaXEQuadJetLineEncoding MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the line encoding, the default is HDB3 for E1, B8ZS for T1." ::= { aprisaXEDualJetIFConfigEntry 5 } aprisaXEDualJetPcmMode OBJECT-TYPE SYNTAX AprisaXEPcmMode MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the PCM mode, PCM31 or PCM30C." ::= { aprisaXEDualJetIFConfigEntry 6 } aprisaXEDualJetClockSource OBJECT-TYPE SYNTAX FourRFNetworkClockSelect MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the port drives the clock soure or not." ::= { aprisaXEDualJetIFConfigEntry 7 } aprisaXEDualJetLineRadioLoopback OBJECT-TYPE SYNTAX AprisaXEQuadJetLoopbacks MAX-ACCESS read-write STATUS current DESCRIPTION "This indicates the E1 loopback setting on a port; OFF, Line or Radio Facing." ::= { aprisaXEDualJetIFConfigEntry 8 } aprisaXEDualJetTxWaveFormShaper OBJECT-TYPE SYNTAX AprisaXEQuadJetWaveFormShapers MAX-ACCESS read-write STATUS current DESCRIPTION "This indicates the T1 Tx Waveform Shaper for a port; 0~133 ft, 133~266 ft, 266~399 ft, 399~533 ft, 533~655 ft." ::= { aprisaXEDualJetIFConfigEntry 9 } -- *************************************************************************** -- End Dual JET -- *************************************************************************** -- *************************************************************************** -- Single E1 Alarms -- *************************************************************************** aprisaXESingleJetBoardTable OBJECT-TYPE SYNTAX SEQUENCE OF AprisaXESingleJetBoardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of Single E1 card specific configuration details." ::= { aprisaXEObjects 225 } aprisaXESingleJetBoardEntry OBJECT-TYPE SYNTAX AprisaXESingleJetBoardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Single E1 configuration details." INDEX { aprisaXESingleJetBoardTableIndex } ::= { aprisaXESingleJetBoardTable 1 } AprisaXESingleJetBoardEntry ::= SEQUENCE { aprisaXESingleJetBoardTableIndex INTEGER } aprisaXESingleJetBoardTableIndex OBJECT-TYPE SYNTAX AprisaXESlotNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Single E1 board indexed by slot." ::= { aprisaXESingleJetBoardEntry 1 } aprisaXESingleJetPortTable OBJECT-TYPE SYNTAX SEQUENCE OF AprisaXESingleJetPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table based on slot and port of SingleJet cards alarms." ::= { aprisaXEObjects 226 } aprisaXESingleJetPortEntry OBJECT-TYPE SYNTAX AprisaXESingleJetPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Single E1 port alarms." INDEX { aprisaXESingleJetPortTableSlot, aprisaXESingleJetPortTablePort } ::= { aprisaXESingleJetPortTable 1 } AprisaXESingleJetPortEntry ::= SEQUENCE { aprisaXESingleJetPortTableSlot INTEGER, aprisaXESingleJetPortTablePort INTEGER, aprisaXESingleJetAISAlarmStatus INTEGER, aprisaXESingleJetAISAlarmSeverity INTEGER, aprisaXESingleJetAISAlarmEnabled INTEGER, aprisaXESingleJetLOSAlarmStatus INTEGER, aprisaXESingleJetLOSAlarmSeverity INTEGER, aprisaXESingleJetLOSAlarmEnabled INTEGER } aprisaXESingleJetPortTableSlot OBJECT-TYPE SYNTAX AprisaXESlotNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Port table index based on slot number." ::= { aprisaXESingleJetPortEntry 1 } aprisaXESingleJetPortTablePort OBJECT-TYPE SYNTAX AprisaXEPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Port table index based on port number." ::= { aprisaXESingleJetPortEntry 2 } aprisaXESingleJetAISAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "AIS alarm status." ::= { aprisaXESingleJetPortEntry 3 } aprisaXESingleJetAISAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "AIS alarm severity." ::= { aprisaXESingleJetPortEntry 4 } aprisaXESingleJetAISAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "AIS alarm enabled or disabled." ::= { aprisaXESingleJetPortEntry 5 } aprisaXESingleJetLOSAlarmStatus OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "LOS alarm status." ::= { aprisaXESingleJetPortEntry 6 } aprisaXESingleJetLOSAlarmSeverity OBJECT-TYPE SYNTAX FourRFAlarmSeverity MAX-ACCESS read-only STATUS current DESCRIPTION "LOS alarm severity." ::= { aprisaXESingleJetPortEntry 7 } aprisaXESingleJetLOSAlarmEnabled OBJECT-TYPE SYNTAX FourRFAlarmEnabled MAX-ACCESS read-only STATUS current DESCRIPTION "LOS alarm enabled or disabled." ::= { aprisaXESingleJetPortEntry 8 } aprisaXESingleJetIFConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF AprisaXESingleJetIFConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Switch data table which describes the allocation of user data on to the TDM busses." ::= { aprisaXEObjects 227 } aprisaXESingleJetIFConfigEntry OBJECT-TYPE SYNTAX AprisaXESingleJetIFConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Single JET config data." INDEX { aprisaXESingleJetIFConfigSlotIndex, aprisaXESingleJetIFConfigPortIndex } ::= { aprisaXESingleJetIFConfigTable 1 } AprisaXESingleJetIFConfigEntry ::= SEQUENCE { aprisaXESingleJetIFConfigSlotIndex INTEGER, aprisaXESingleJetIFConfigPortIndex INTEGER, aprisaXESingleJetTrafficType INTEGER, aprisaXESingleJetLoopback INTEGER, aprisaXESingleJetLineEncoding INTEGER, aprisaXESingleJetPcmMode INTEGER, aprisaXESingleJetClockSource INTEGER, aprisaXESingleJetLineRadioLoopback INTEGER, aprisaXESingleJetTxWaveFormShaper INTEGER } aprisaXESingleJetIFConfigSlotIndex OBJECT-TYPE SYNTAX AprisaXESlotNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Index to the port table based on port number." ::= { aprisaXESingleJetIFConfigEntry 1 } aprisaXESingleJetIFConfigPortIndex OBJECT-TYPE SYNTAX AprisaXEPortNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Index to the port table based on port number." ::= { aprisaXESingleJetIFConfigEntry 2 } aprisaXESingleJetTrafficType OBJECT-TYPE SYNTAX AprisaXEQuadJetTrafficType MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the traffic type on a Single JET port." ::= { aprisaXESingleJetIFConfigEntry 3 } aprisaXESingleJetLoopback OBJECT-TYPE SYNTAX FourRFLoopback MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Controls the traffic loopback on a Single JET port." ::= { aprisaXESingleJetIFConfigEntry 4 } aprisaXESingleJetLineEncoding OBJECT-TYPE SYNTAX AprisaXEQuadJetLineEncoding MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the line encoding, the default is HDB3 for E1, B8ZS for T1." ::= { aprisaXESingleJetIFConfigEntry 5 } aprisaXESingleJetPcmMode OBJECT-TYPE SYNTAX AprisaXEPcmMode MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the PCM mode, PCM31 or PCM30C." ::= { aprisaXESingleJetIFConfigEntry 6 } aprisaXESingleJetClockSource OBJECT-TYPE SYNTAX FourRFNetworkClockSelect MAX-ACCESS read-write STATUS current DESCRIPTION "Controls whether the port drives the clock soure or not." ::= { aprisaXESingleJetIFConfigEntry 7 } aprisaXESingleJetLineRadioLoopback OBJECT-TYPE SYNTAX AprisaXEQuadJetLoopbacks MAX-ACCESS read-write STATUS current DESCRIPTION "This indicates the E1 loopback setting on a port; OFF, Line or Radio Facing." ::= { aprisaXESingleJetIFConfigEntry 8 } aprisaXESingleJetTxWaveFormShaper OBJECT-TYPE SYNTAX AprisaXEQuadJetWaveFormShapers MAX-ACCESS read-write STATUS current DESCRIPTION "This indicates the T1 Tx Waveform Shaper for a port; 0~133 ft, 133~266 ft, 266~399 ft, 399~533 ft, 533~655 ft." ::= { aprisaXESingleJetIFConfigEntry 9 } -- *************************************************************************** -- End Single JET -- *************************************************************************** -- *************************************************************************** -- PSC -- *************************************************************************** aprisaXEPSCControlTable OBJECT-TYPE SYNTAX SEQUENCE OF AprisaXEPSCControlTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Control table for PSC." ::= { aprisaXEObjects 230 } aprisaXEPSCControlTableEntry OBJECT-TYPE SYNTAX AprisaXEPSCControlTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries for PSC table." INDEX { aprisaXEPSCControlSlotIndex } ::= { aprisaXEPSCControlTable 1 } AprisaXEPSCControlTableEntry ::= SEQUENCE { aprisaXEPSCControlSlotIndex INTEGER, aprisaXEPSCActiveRadio AprisaXEPSCActiveRadio, aprisaXEPSCActiveTx AprisaXEPSCActiveTx, aprisaXEPSCDemodAligmentStatusPSC FourRFAlarmStatus, aprisaXEPSCDemodAligmentStatusPIC FourRFAlarmStatus } aprisaXEPSCControlSlotIndex OBJECT-TYPE SYNTAX AprisaXESlotNumber MAX-ACCESS read-only STATUS current DESCRIPTION "Slot index for PSC Control Table." ::= { aprisaXEPSCControlTableEntry 1 } aprisaXEPSCActiveRadio OBJECT-TYPE SYNTAX AprisaXEPSCActiveRadio MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the reception mode of the PSC." ::= { aprisaXEPSCControlTableEntry 2 } aprisaXEPSCActiveTx OBJECT-TYPE SYNTAX AprisaXEPSCActiveTx MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the currently active transmitter." ::= { aprisaXEPSCControlTableEntry 3 } aprisaXEPSCDemodAlignmentStatusPSC OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the demodulator alignment on the PSC." ::= { aprisaXEPSCControlTableEntry 4 } aprisaXEPSCDemodAlignmentStatusPIC OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the demodulator alignment on the PIC." ::= { aprisaXEPSCControlTableEntry 5 } -- *************************************************************************** -- End PSC -- *************************************************************************** -- *************************************************************************** -- HSD Parameter Comparison -- *************************************************************************** aprisaXEHSDParameterCompare OBJECT IDENTIFIER ::= { aprisaXEObjects 235 } aprisaXEHSDParameterMismatch OBJECT-TYPE SYNTAX FourRFAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "If there is a parameter (OID) mismatch between Radio A and Radio B" ::= { aprisaXEHSDParameterCompare 1 } aprisaXEHSDParameterCompareChecking OBJECT-TYPE SYNTAX INTEGER { off (0), on (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables/disables HSD paramter compare checking between Radio A and Radio B" ::= { aprisaXEHSDParameterCompare 2 } aprisaXEHSDParameterCompareGroup OBJECT-GROUP OBJECTS { aprisaXEHSDParameterMismatch, aprisaXEHSDParameterCompareChecking } STATUS current DESCRIPTION "The AprisaXE HSD Parameter Comparison group." ::= { aprisaXEGroups 305 } -- *************************************************************************** -- HSD Parameter Comparison -- *************************************************************************** END