FRAME-RELAY-DTE-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Counter32, Integer32, NOTIFICATION-TYPE FROM SNMPv2-SMI TEXTUAL-CONVENTION, RowStatus, TimeStamp FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF transmission FROM RFC1213-MIB InterfaceIndex FROM IF-MIB; -- Frame Relay DTE MIB frameRelayDTE MODULE-IDENTITY LAST-UPDATED "9705010229Z" -- Thu May 1 02:29:46 PDT 1997 ORGANIZATION "IETF IPLPDN Working Group" CONTACT-INFO " Caralyn Brown Postal: Cadia Networks, Inc. 1 Corporate Drive Andover, Massachusetts 01810 Tel: +1 508 689 2400 x133 E-Mail: cbrown@cadia.com Fred Baker Postal: Cisco Systems 519 Lado Drive Santa Barbara, California 93111 Tel: +1 408 526 425 E-Mail: fred@cisco.com" DESCRIPTION "The MIB module to describe the use of a Frame Relay interface by a DTE." REVISION "9705010229Z" -- Thu May 1 02:29:46 PDT 1997 DESCRIPTION "Converted from SMIv1 to SMIv2. (Thus, indices are read-only rather than being not-accessible.) Added objects and made clarifications based on implementation experience." REVISION "9204010000Z" DESCRIPTION "Published as RFC 1315, the initial version of this MIB module." ::= { transmission 32 } -- -- the range of a Data Link Connection Identifier -- DLCI ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The range of DLCI values. Note that this varies by interface configuration; normally, interfaces may use 0..1023, but may be configured to use ranges as large as 0..2^23." SYNTAX Integer32(0..8388607) -- -- Data Link Connection Management Interface -- The variables that configure the DLC Management Interface. frDlcmiTable OBJECT-TYPE SYNTAX SEQUENCE OF FrDlcmiEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Parameters for the Data Link Connection Management Interface for the frame relay service on this interface." REFERENCE "American National Standard T1.617-1991, Annex D" ::= { frameRelayDTE 1 } frDlcmiEntry OBJECT-TYPE SYNTAX FrDlcmiEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Parameters for a particular Data Link Connection Management Interface." INDEX { frDlcmiIfIndex } ::= { frDlcmiTable 1 } FrDlcmiEntry ::= SEQUENCE { frDlcmiIfIndex InterfaceIndex, frDlcmiState INTEGER, frDlcmiAddress INTEGER, frDlcmiAddressLen INTEGER, frDlcmiPollingInterval Integer32, frDlcmiFullEnquiryInterval Integer32, frDlcmiErrorThreshold Integer32, frDlcmiMonitoredEvents Integer32, frDlcmiMaxSupportedVCs DLCI, frDlcmiMulticast INTEGER, frDlcmiStatus INTEGER, frDlcmiRowStatus RowStatus } frDlcmiIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex value of the corresponding ifEntry." ::= { frDlcmiEntry 1 } frDlcmiState OBJECT-TYPE SYNTAX INTEGER { noLmiConfigured (1), lmiRev1 (2), ansiT1617D (3), -- ANSI T1.617 Annex D ansiT1617B (4), -- ANSI T1.617 Annex B itut933A (5), -- CCITT Q933 Annex A ansiT1617D1994 (6) -- ANSI T1.617a-1994 Annex D } MAX-ACCESS read-create STATUS current DESCRIPTION "This variable states which Data Link Connection Management scheme is active (and by implication, what DLCI it uses) on the Frame Relay interface." REFERENCE "American National Standard T1.617-1991, American National Standard T1.617a-1994, ITU-T Recommendation Q.933 (03/93)." ::= { frDlcmiEntry 2 } frDlcmiAddress OBJECT-TYPE SYNTAX INTEGER { q921 (1), -- 13 bit DLCI q922March90 (2), -- 11 bit DLCI q922November90 (3), -- 10 bit DLCI q922 (4) -- Final Standard } MAX-ACCESS read-create STATUS current DESCRIPTION "This variable states which address format is in use on the Frame Relay interface." ::= { frDlcmiEntry 3 } frDlcmiAddressLen OBJECT-TYPE SYNTAX INTEGER { twoOctets (2), threeOctets (3), fourOctets (4) } MAX-ACCESS read-create STATUS current DESCRIPTION "This variable states the address length in octets. In the case of Q922 format, the length indicates the entire length of the address including the control portion." ::= { frDlcmiEntry 4 } frDlcmiPollingInterval OBJECT-TYPE SYNTAX Integer32 (5..30) UNITS "seconds" MAX-ACCESS read-create STATUS current DESCRIPTION "This is the number of seconds between successive status enquiry messages." REFERENCE "American National Standard T1.617-1991, Section D.7 Timer T391." DEFVAL { 10 } ::= { frDlcmiEntry 5 } frDlcmiFullEnquiryInterval OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-create STATUS current DESCRIPTION "Number of status enquiry intervals that pass before issuance of a full status enquiry message." REFERENCE "American National Standard T1.617-1991, Section D.7 Counter N391." DEFVAL { 6 } ::= { frDlcmiEntry 6 } frDlcmiErrorThreshold OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-create STATUS current DESCRIPTION "This is the maximum number of unanswered Status Enquiries the equipment shall accept before declaring the interface down." REFERENCE "American National Standard T1.617-1991, Section D.5.1 Counter N392." DEFVAL { 3 } ::= { frDlcmiEntry 7 } frDlcmiMonitoredEvents OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-create STATUS current DESCRIPTION "This is the number of status polling intervals over which the error threshold is counted. For example, if within 'MonitoredEvents' number of events the station receives 'ErrorThreshold' number of errors, the interface is marked as down." REFERENCE "American National Standard T1.617-1991, Section D.5.2 Counter N393." DEFVAL { 4 } ::= { frDlcmiEntry 8 } frDlcmiMaxSupportedVCs OBJECT-TYPE SYNTAX DLCI MAX-ACCESS read-create STATUS current DESCRIPTION "The maximum number of Virtual Circuits allowed for this interface. Usually dictated by the Frame Relay network. In response to a SET, if a value less than zero or higher than the agent's maximal capability is configured, the agent should respond badValue" ::= { frDlcmiEntry 9 } frDlcmiMulticast OBJECT-TYPE SYNTAX INTEGER { nonBroadcast (1), broadcast (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This indicates whether the Frame Relay interface is using a multicast service." ::= { frDlcmiEntry 10 } frDlcmiStatus OBJECT-TYPE SYNTAX INTEGER { running (1), -- init complete, system running fault (2), -- error threshold exceeded initializing (3) -- system start up } MAX-ACCESS read-only STATUS current DESCRIPTION "This indicates the status of the Frame Relay interface as determined by the performance of the dlcmi. If no dlcmi is running, the Frame Relay interface will stay in the running state indefinitely." ::= { frDlcmiEntry 11 } frDlcmiRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "SNMP Version 2 Row Status Variable. Writable objects in the table may be written in any RowStatus state." ::= { frDlcmiEntry 12 } -- -- A Frame Relay service is a multiplexing service. Data -- Link Connection Identifiers enumerate virtual circuits -- (permanent or dynamic) which are layered onto the underlying -- circuit, represented by ifEntry. Therefore, each of the entries -- in the Standard MIB's Interface Table with an IfType of -- Frame Relay represents a Q.922 interface. Zero or more -- virtual circuits are layered onto this interface and provide -- interconnection with various remote destinations. -- Each such virtual circuit is represented by an entry in the -- circuit table. The management virtual circuit (i.e. DLCI 0) -- is a virtual circuit by this definition and will be represented -- with an entry in the circuit table. -- Circuit Table -- The table describing the use of the DLCIs attached to -- each Frame Relay Interface. frCircuitTable OBJECT-TYPE SYNTAX SEQUENCE OF FrCircuitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing information about specific Data Link Connections (DLC) or virtual circuits." ::= { frameRelayDTE 2 } frCircuitEntry OBJECT-TYPE SYNTAX FrCircuitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The information regarding a single Data Link Connection. Discontinuities in the counters contained in this table are indicated by the value in frCircuitCreationTime." INDEX { frCircuitIfIndex, frCircuitDlci } ::= { frCircuitTable 1 } FrCircuitEntry ::= SEQUENCE { frCircuitIfIndex InterfaceIndex, frCircuitDlci DLCI, frCircuitState INTEGER, frCircuitReceivedFECNs Counter32, frCircuitReceivedBECNs Counter32, frCircuitSentFrames Counter32, frCircuitSentOctets Counter32, frCircuitReceivedFrames Counter32, frCircuitReceivedOctets Counter32, frCircuitCreationTime TimeStamp, frCircuitLastTimeChange TimeStamp, frCircuitCommittedBurst Integer32, frCircuitExcessBurst Integer32, frCircuitThroughput Integer32, frCircuitMulticast INTEGER, frCircuitType INTEGER, frCircuitDiscards Counter32, frCircuitReceivedDEs Counter32, frCircuitSentDEs Counter32, frCircuitLogicalIfIndex InterfaceIndex, frCircuitRowStatus RowStatus } frCircuitIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex Value of the ifEntry this virtual circuit is layered onto." ::= { frCircuitEntry 1 } frCircuitDlci OBJECT-TYPE SYNTAX DLCI MAX-ACCESS read-only STATUS current DESCRIPTION "The Data Link Connection Identifier for this virtual circuit." REFERENCE "American National Standard T1.618-1991, Section 3.3.6" ::= { frCircuitEntry 2 } frCircuitState OBJECT-TYPE SYNTAX INTEGER { invalid (1), active (2), inactive (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates whether the particular virtual circuit is operational. In the absence of a Data Link Connection Management Interface, virtual circuit entries (rows) may be created by setting virtual circuit state to 'active', or deleted by changing Circuit state to 'invalid'. Whether or not the row actually disappears is left to the implementation, so this object may actually read as 'invalid' for some arbitrary length of time. It is also legal to set the state of a virtual circuit to 'inactive' to temporarily disable a given circuit. The use of 'invalid' is deprecated in this SNMP Version 2 MIB, in favor of frCircuitRowStatus." DEFVAL { active } ::= { frCircuitEntry 3 } frCircuitReceivedFECNs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of frames received from the network indicating forward congestion since the virtual circuit was created. This occurs when the remote DTE sets the FECN flag, or when a switch in the network enqueues the frame to a trunk whose transmission queue is congested." REFERENCE "American National Standard T1.618-1991, Section 3.3.3" ::= { frCircuitEntry 4 } frCircuitReceivedBECNs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of frames received from the network indicating backward congestion since the virtual circuit was created. This occurs when the remote DTE sets the BECN flag, or when a switch in the network receives the frame from a trunk whose transmission queue is congested." REFERENCE "American National Standard T1.618-1991, Section 3.3.4" ::= { frCircuitEntry 5 } frCircuitSentFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames sent from this virtual circuit since it was created." ::= { frCircuitEntry 6 } frCircuitSentOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets sent from this virtual circuit since it was created. Octets counted are the full frame relay header and the payload, but do not include the flag characters or CRC." ::= { frCircuitEntry 7 } frCircuitReceivedFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of frames received over this virtual circuit since it was created." ::= { frCircuitEntry 8 } frCircuitReceivedOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of octets received over this virtual circuit since it was created. Octets counted include the full frame relay header, but do not include the flag characters or the CRC." ::= { frCircuitEntry 9 } frCircuitCreationTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime when the virtual circuit was created, whether by the Data Link Connection Management Interface or by a SetRequest." ::= { frCircuitEntry 10 } frCircuitLastTimeChange OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime when last there was a change in the virtual circuit state" ::= { frCircuitEntry 11 } frCircuitCommittedBurst OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-create STATUS current DESCRIPTION "This variable indicates the maximum amount of data, in bits, that the network agrees to transfer under normal conditions, during the measurement interval." REFERENCE "American National Standard T1.617-1991, Section 6.5.19" DEFVAL { 0 } -- the default indicates no commitment ::= { frCircuitEntry 12 } frCircuitExcessBurst OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-create STATUS current DESCRIPTION "This variable indicates the maximum amount of uncommitted data bits that the network will attempt to deliver over the measurement interval. By default, if not configured when creating the entry, the Excess Information Burst Size is set to the value of ifSpeed." REFERENCE "American National Standard T1.617-1991, Section 6.5.19" ::= { frCircuitEntry 13 } frCircuitThroughput OBJECT-TYPE SYNTAX Integer32(0..2147483647) MAX-ACCESS read-create STATUS current DESCRIPTION "Throughput is the average number of 'Frame Relay Information Field' bits transferred per second across a user network interface in one direction, measured over the measurement interval. If the configured committed burst rate and throughput are both non-zero, the measurement interval, T, is T=frCircuitCommittedBurst/frCircuitThroughput. If the configured committed burst rate and throughput are both zero, the measurement interval, T, is T=frCircuitExcessBurst/ifSpeed." REFERENCE "American National Standard T1.617-1991, Section 6.5.19" DEFVAL {0} -- the default value of Throughput is -- "no commitment". ::= { frCircuitEntry 14 } frCircuitMulticast OBJECT-TYPE SYNTAX INTEGER { unicast (1), oneWay (2), twoWay (3), nWay (4) } MAX-ACCESS read-create STATUS current DESCRIPTION "This indicates whether this VC is used as a unicast VC (i.e. not multicast) or the type of multicast service subscribed to" REFERENCE "Frame Relay PVC Multicast Service and Protocol Description Implementation: FRF.7 Frame Relay Forum Technical Committe October 21, 1994" DEFVAL {unicast} -- the default value of frCircuitMulticast is -- "unicast" (not a multicast VC). ::= { frCircuitEntry 15 } frCircuitType OBJECT-TYPE SYNTAX INTEGER { static (1), dynamic (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indication of whether the VC was manually created (static), or dynamically created (dynamic) via the data link control management interface." ::= { frCircuitEntry 16 } frCircuitDiscards OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of inbound frames dropped because of format errors, or because the VC is inactive." ::= { frCircuitEntry 17 } frCircuitReceivedDEs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of frames received from the network indicating that they were eligible for discard since the virtual circuit was created. This occurs when the remote DTE sets the DE flag, or when in remote DTE's switch detects that the frame was received as Excess Burst data." REFERENCE "American National Standard T1.618-1991, Section 3.3.4" ::= { frCircuitEntry 18 } frCircuitSentDEs OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of frames sent to the network indicating that they were eligible for discard since the virtual circuit was created. This occurs when the local DTE sets the DE flag, indicating that during Network congestion situations those frames should be discarded in preference of other frames sent without the DE bit set." REFERENCE "American National Standard T1.618-1991, Section 3.3.4" ::= { frCircuitEntry 19 } frCircuitLogicalIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-create STATUS current DESCRIPTION "Normally the same value as frDlcmiIfIndex, but different when an implementation associates a virtual ifEntry with a DLC or set of DLCs in order to associate higher layer objects such as the ipAddrEntry with a subset of the virtual circuits on a Frame Relay interface. The type of such ifEntries is defined by the higher layer object; for example, if PPP/Frame Relay is implemented, the ifType of this ifEntry would be PPP. If it is not so defined, as would be the case with an ipAddrEntry, it should be of type Other." ::= { frCircuitEntry 20 } frCircuitRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object is used to create a new row or modify or destroy an existing row in the manner described in the definition of the RowStatus textual convention. Writable objects in the table may be written in any RowStatus state." ::= { frCircuitEntry 21 } -- -- Error Table -- The table describing errors encountered on each Frame -- Relay Interface. frErrTable OBJECT-TYPE SYNTAX SEQUENCE OF FrErrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing information about Errors on the Frame Relay interface. Discontinuities in the counters contained in this table are the same as apply to the ifEntry associated with the Interface." ::= { frameRelayDTE 3 } frErrEntry OBJECT-TYPE SYNTAX FrErrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The error information for a single frame relay interface." INDEX { frErrIfIndex } ::= { frErrTable 1 } FrErrEntry ::= SEQUENCE { frErrIfIndex InterfaceIndex, frErrType INTEGER, frErrData OCTET STRING, frErrTime TimeStamp, frErrFaults Counter32, frErrFaultTime TimeStamp } frErrIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex Value of the corresponding ifEntry." ::= { frErrEntry 1 } frErrType OBJECT-TYPE SYNTAX INTEGER { unknownError(1), receiveShort(2), receiveLong(3), illegalAddress(4), unknownAddress(5), dlcmiProtoErr(6), dlcmiUnknownIE(7), dlcmiSequenceErr(8), dlcmiUnknownRpt(9), noErrorSinceReset(10) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of error that was last seen on this interface: receiveShort: frame was not long enough to allow demultiplexing - the address field was incomplete, or for virtual circuits using Multiprotocol over Frame Relay, the protocol identifier was missing or incomplete. receiveLong: frame exceeded maximum length configured for this interface. illegalAddress: address field did not match configured format. unknownAddress: frame received on a virtual circuit which was not active or administratively disabled. dlcmiProtoErr: unspecified error occurred when attempting to interpret link maintenance frame. dlcmiUnknownIE: link maintenance frame contained an Information Element type which is not valid for the configured link maintenance protocol. dlcmiSequenceErr: link maintenance frame contained a sequence number other than the expected value. dlcmiUnknownRpt: link maintenance frame contained a Report Type Information Element whose value was not valid for the configured link maintenance protocol. noErrorSinceReset: no errors have been detected since the last cold start or warm start." ::= { frErrEntry 2 } frErrData OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..1600)) MAX-ACCESS read-only STATUS current DESCRIPTION "An octet string containing as much of the error packet as possible. As a minimum, it must contain the Q.922 Address or as much as was delivered. It is desirable to include all header and demultiplexing information." ::= { frErrEntry 3 } frErrTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime at which the error was detected." ::= { frErrEntry 4 } frErrFaults OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times the interface has gone down since it was initialized." ::= { frErrEntry 5 } frErrFaultTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime at the time when the interface was taken down due to excessive errors. Excessive errors is defined as the time when a DLCMI exceeds the frDlcmiErrorThreshold number of errors within frDlcmiMonitoredEvents. See FrDlcmiEntry for further details." ::= { frErrEntry 6 } -- -- Frame Relay Trap Control frameRelayTrapControl OBJECT IDENTIFIER ::= { frameRelayDTE 4 } -- the following highly unusual OID is as it is for compatibility -- with RFC 1315, the SNMP V1 predecessor of this document. frameRelayTraps OBJECT IDENTIFIER ::= { frameRelayDTE 0 } frTrapState OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable indicates whether the system produces the frDLCIStatusChange trap." DEFVAL { disabled } ::= { frameRelayTrapControl 1 } frTrapMaxRate OBJECT-TYPE SYNTAX Integer32 (0..3600000) MAX-ACCESS read-write STATUS current DESCRIPTION "This variable indicates the number of milliseconds that must elapse between trap emissions. If events occur more rapidly, the impementation may simply fail to trap, or may queue traps until an appropriate time." DEFVAL { 0 } -- no minimum elapsed period is specified ::= { frameRelayTrapControl 2 } -- Data Link Connection Management Interface Related Traps frDLCIStatusChange NOTIFICATION-TYPE OBJECTS { frCircuitState } STATUS current DESCRIPTION "This trap indicates that the indicated Virtual Circuit has changed state. It has either been created or invalidated, or has toggled between the active and inactive states. If, however, the reason for the state change is due to the DLCMI going down, per-DLCI traps should not be generated." ::= { frameRelayTraps 1 } -- conformance information frConformance OBJECT IDENTIFIER ::= { frameRelayDTE 6 } frGroups OBJECT IDENTIFIER ::= { frConformance 1 } frCompliances OBJECT IDENTIFIER ::= { frConformance 2 } -- compliance statements frCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement " MODULE -- this module MANDATORY-GROUPS { frPortGroup, frCircuitGroup } GROUP frErrGroup DESCRIPTION "This optional group is used for debugging Frame Relay Systems." GROUP frTrapGroup DESCRIPTION "This optional group is used for the management of asynchronous notifications by Frame Relay Systems." GROUP frNotificationGroup DESCRIPTION "This optional group defines the asynchronous notifications generated by Frame Relay Systems." OBJECT frDlcmiRowStatus MIN-ACCESS read-only DESCRIPTION "Row creation is not required for the frDlcmiTable." OBJECT frCircuitRowStatus MIN-ACCESS read-only DESCRIPTION "Row creation is not required for the frCircuitTable." ::= { frCompliances 1 } frCompliance0 MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for objects and the trap defined in RFC 1315." MODULE -- this module MANDATORY-GROUPS { frPortGroup0, frCircuitGroup0 } GROUP frErrGroup0 DESCRIPTION "This optional group is used for debugging Frame Relay Systems." GROUP frTrapGroup0 DESCRIPTION "This optional group is used for the management of asynchronous notifications by Frame Relay Systems." GROUP frNotificationGroup DESCRIPTION "This optional group defines the asynchronous notifications generated by Frame Relay Systems." ::= { frCompliances 2 } -- units of conformance frPortGroup OBJECT-GROUP OBJECTS { frDlcmiIfIndex, frDlcmiState, frDlcmiAddress, frDlcmiAddressLen, frDlcmiPollingInterval, frDlcmiFullEnquiryInterval, frDlcmiErrorThreshold, frDlcmiMonitoredEvents, frDlcmiMaxSupportedVCs, frDlcmiMulticast, frDlcmiStatus, frDlcmiRowStatus } STATUS current DESCRIPTION "The objects necessary to control the Link Management Interface for a Frame Relay Interface as well as maintain the error statistics on this interface." ::= { frGroups 1 } frCircuitGroup OBJECT-GROUP OBJECTS { frCircuitIfIndex, frCircuitDlci, frCircuitState, frCircuitReceivedFECNs, frCircuitReceivedBECNs, frCircuitSentFrames, frCircuitSentOctets, frCircuitReceivedFrames, frCircuitReceivedOctets, frCircuitCreationTime, frCircuitLastTimeChange, frCircuitCommittedBurst, frCircuitExcessBurst, frCircuitThroughput, frCircuitMulticast, frCircuitType, frCircuitDiscards, frCircuitReceivedDEs, frCircuitSentDEs, frCircuitLogicalIfIndex, frCircuitRowStatus } STATUS current DESCRIPTION "The objects necessary to control the Virtual Circuits layered onto a Frame Relay Interface." ::= { frGroups 2 } frTrapGroup OBJECT-GROUP OBJECTS { frTrapState, frTrapMaxRate } STATUS current DESCRIPTION "The objects necessary to control a Frame Relay Interface's notification messages." ::= { frGroups 3 } frErrGroup OBJECT-GROUP OBJECTS { frErrIfIndex, frErrType, frErrData, frErrTime, frErrFaults, frErrFaultTime } STATUS current DESCRIPTION "Objects designed to assist in debugging Frame Relay Interfaces." ::= { frGroups 4 } frNotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { frDLCIStatusChange } STATUS current DESCRIPTION "Traps which may be used to enhance event driven management of the interface." ::= { frGroups 5 } frPortGroup0 OBJECT-GROUP OBJECTS { frDlcmiIfIndex, frDlcmiState, frDlcmiAddress, frDlcmiAddressLen, frDlcmiPollingInterval, frDlcmiFullEnquiryInterval, frDlcmiErrorThreshold, frDlcmiMonitoredEvents, frDlcmiMaxSupportedVCs, frDlcmiMulticast } STATUS current DESCRIPTION "The objects necessary to control the Link Management Interface for a Frame Relay Interface as well as maintain the error statistics on this interface from RFC 1315." ::= { frGroups 6 } frCircuitGroup0 OBJECT-GROUP OBJECTS { frCircuitIfIndex, frCircuitDlci, frCircuitState, frCircuitReceivedFECNs, frCircuitReceivedBECNs, frCircuitSentFrames, frCircuitSentOctets, frCircuitReceivedFrames, frCircuitReceivedOctets, frCircuitCreationTime, frCircuitLastTimeChange, frCircuitCommittedBurst, frCircuitExcessBurst, frCircuitThroughput } STATUS current DESCRIPTION "The objects necessary to control the Virtual Circuits layered onto a Frame Relay Interface from RFC 1315." ::= { frGroups 7 } frErrGroup0 OBJECT-GROUP OBJECTS { frErrIfIndex, frErrType, frErrData, frErrTime } STATUS current DESCRIPTION "Objects designed to assist in debugging Frame Relay Interfaces from RFC 1315." ::= { frGroups 8 } frTrapGroup0 OBJECT-GROUP OBJECTS { frTrapState } STATUS current DESCRIPTION "The objects necessary to control a Frame Relay Interface's notification messages from RFC 1315." ::= { frGroups 9 } END