-- SML MIB Rev 1.12 -- ASN.1 code created using dot2asn -- by Jeff Bain -- Hewlett Packard, Storage Systems Division -- Greeley, CO -- jeff_bain@hp.com SML-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE FROM RFC-1212 enterprises FROM RFC1155-SMI DisplayString FROM RFC1213-MIB ; -- Textual Conventions UShortReal ::= INTEGER (0..'ffff'h) -- This textual convention can be used to represent short -- unsigned 'real' numbers. Using this variable type, -- a 3 digit number with 2 decimal places (xxx.xx) -- can be represented. For example, 321.45 would be -- represented as 32145" CimDateTime ::= OCTET STRING (SIZE (24)) -- This textual convention can be used to represent a date -- and time using the CIM DateTime convention. The bytes are -- as follows: -- octets contents range -- ====== ======== ===== -- 1-4 year 0000-9999 -- 5-6 month 01-12 -- 7-8 day 01-31 -- 9-10 hour 00-23 -- 11-12 minute 00-59 -- 13-14 second 00-59 -- 15-20 microseconds 000000-999999 -- 21 sign '+' or '-' -- 22-24 UTC offset in minutes 000-839 -- For example, Monday, May 25, 1998, at 1:30:15 PM EST would be -- represented as 19980525133015000000-300 -- Note that values must be zero-padded so that the entire -- string is always the same 25-character length. Fields that -- are not significant can be replaced with asterisk characters" UINT64 ::= OCTET STRING (SIZE (8)) -- This textual convention can be used to represent 64-bit -- numbers using the OCTET STRING type. SNMPv2 supports a -- Counter64 type, but there is no C-language mapping for a -- 64-bit variable that's much better than an array of 8 bytes UINT32 ::= INTEGER (0..'7fffffff'h) UINT16 ::= INTEGER (0..'ffff'h) -- MIB Fields ibm OBJECT IDENTIFIER ::= { enterprises 2 } ibmProd OBJECT IDENTIFIER ::= { ibm 6 } ibm3584 OBJECT IDENTIFIER ::= { ibmProd 182 } smlRoot OBJECT IDENTIFIER ::= { ibm3584 3 } smlMibVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..4)) ACCESS read-only STATUS mandatory DESCRIPTION "This string contains version information for the MIB file" ::= { smlRoot 1 } smlCimVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..4)) ACCESS read-only STATUS mandatory DESCRIPTION "This string contains information about the CIM version that corresponds to the MIB. The decriptions in this MIB file are based on CIM version 2.7, as documented by Steve Jerman for HP." ::= { smlRoot 2 } productGroup OBJECT IDENTIFIER ::= { smlRoot 3 } product-Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Commonly used Product name." ::= { productGroup 1 } product-IdentifyingNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Product identification such as a serial number on software, a die number on a hardware chip, or (for non-commercial Products) a project number." ::= { productGroup 2 } product-Vendor OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The name of the Product's supplier, or entity selling the Product (the manufacturer, reseller, OEM, etc.). Corresponds to the Vendor property in the Product object in the DMTF Solution Exchange Standard." ::= { productGroup 3 } product-Version OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Product version information. Corresponds to the Version property in the Product object in the DMTF Solution Exchange Standard." ::= { productGroup 4 } chassisGroup OBJECT IDENTIFIER ::= { smlRoot 4 } chassis-Manufacturer OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The name of the organization responsible for producing the PhysicalElement. This may be the entity from whom the Element is purchased, but this is not necessarily true. The latter information is contained in the Vendor property of CIM_Product." ::= { chassisGroup 1 } chassis-Model OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "The name by which the PhysicalElement is generally known." ::= { chassisGroup 2 } chassis-SerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "A manufacturer-allocated number used to identify the Physical Element." ::= { chassisGroup 3 } chassis-LockPresent OBJECT-TYPE SYNTAX INTEGER { unknown (0), true (1), false (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Boolean indicating whether the Frame is protected with a lock." ::= { chassisGroup 4 } chassis-SecurityBreach OBJECT-TYPE SYNTAX INTEGER { unknown (0), other (1), noBreach (2), breachAttempted (3) } ACCESS read-only STATUS mandatory DESCRIPTION "SecurityBreach is an enumerated, integer-valued property indicating whether a physical breach of the Frame was attempted but unsuccessful (value=4) or attempted and successful (5). Also, the values, 'Unknown', 'Other' or 'No Breach', can be specified." ::= { chassisGroup 5 } chassis-IsLocked OBJECT-TYPE SYNTAX INTEGER { unknown (0), true (1), false (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Boolean indicating that the Frame is currently locked." ::= { chassisGroup 6 } storageLibraryGroup OBJECT IDENTIFIER ::= { smlRoot 5 } storageLibrary-Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The inherited Name serves as key of a System instance in an enterprise environment." ::= { storageLibraryGroup 1 } storageLibrary-Description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The Description property provides a textual description of the object." ::= { storageLibraryGroup 2 } storageLibrary-Caption OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "The Caption property is a short textual description (one- line string) of the object." ::= { storageLibraryGroup 3 } storageLibrary-Status OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) ACCESS read-only STATUS mandatory DESCRIPTION "A string indicating the current status of the object. Various operational and non-operational statuses are defined. This property is deprecated in lieu of OperationalStatus, which includes the same semantics in its enumeration. This change is made for three reasons: 1) Status is more correctly defined as an array property. This overcomes the limitation of describing status via a single value, when it is really a multi-valued property (for example, an element may be OK AND Stopped. 2) A MaxLen of 10 is too restrictive and leads to unclear enumerated values. And, 3) The change to a uint16 data type was discussed when CIM V2.0 was defined. However, existing V1.0 implementations used the string property and did not want to modify their code. Therefore, Status was grandfathered into the Schema. Use of the Deprecated qualifier allows the maintenance of the existing property, but also permits an improved definition using OperationalStatus." ::= { storageLibraryGroup 4 } storageLibrary-InstallDate OBJECT-TYPE SYNTAX CimDateTime ACCESS read-only STATUS mandatory DESCRIPTION "A datetime value indicating when the object was installed. A lack of a value does not indicate that the object is not installed." ::= { storageLibraryGroup 5 } mediaAccessDeviceGroup OBJECT IDENTIFIER ::= { smlRoot 6 } numberOfMediaAccessDevices OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the number of MediaAccessDevices that are present." ::= { mediaAccessDeviceGroup 1 } mediaAccessDeviceTable OBJECT-TYPE SYNTAX SEQUENCE OF TableInfo-1 ACCESS not-accessible STATUS mandatory DESCRIPTION "A MediaAccessDevice represents the ability to access one or more media and use this media to store and retrieve data." ::= { mediaAccessDeviceGroup 2 } mediaAccessDeviceEntry OBJECT-TYPE SYNTAX TableInfo-1 ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry in the table contains information about a MediaAccessDevice that is present in the library." INDEX { mediaAccessDeviceIndex } ::= { mediaAccessDeviceTable 1 } TableInfo-1 ::= SEQUENCE { mediaAccessDeviceIndex UINT32, mediaAccessDeviceObjectType INTEGER, mediaAccessDevice-Name DisplayString, mediaAccessDevice-Status DisplayString, mediaAccessDevice-Availability INTEGER, mediaAccessDevice-NeedsCleaning INTEGER } mediaAccessDeviceIndex OBJECT-TYPE SYNTAX UINT32 ACCESS read-only STATUS mandatory DESCRIPTION "The current index value for the MediaAccessDevice." ::= { mediaAccessDeviceEntry 1 } mediaAccessDeviceObjectType OBJECT-TYPE SYNTAX INTEGER { unknown (0), wormDrive (1), magnetoOpticalDrive (2), tapeDrive (3), dvdDrive (4), cdromDrive (5) } ACCESS read-only STATUS mandatory DESCRIPTION "In the 2.7 CIM Schema a Type property is no longer associated with MediaAccessDevice. However, it can be used here to specify the type of drive that is present." ::= { mediaAccessDeviceEntry 2 } mediaAccessDevice-Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The Name property defines the label by which the object is known. When subclassed, the Name property can be overridden to be a Key property." ::= { mediaAccessDeviceEntry 3 } mediaAccessDevice-Status OBJECT-TYPE SYNTAX DisplayString (SIZE (0..10)) ACCESS read-only STATUS mandatory DESCRIPTION "A string indicating the current status of the object. Various operational and non-operational statuses are defined. This property is deprecated in lieu of OperationalStatus, which includes the same semantics in its enumeration. This change is made for three reasons: 1) Status is more correctly defined as an array property. This overcomes the limitation of describing status via a single value, when it is really a multi-valued property (for example, an element may be OK AND Stopped. 2) A MaxLen of 10 is too restrictive and leads to unclear enumerated values. And, 3) The change to a uint16 data type was discussed when CIM V2.0 was defined. However, existing V1.0 implementations used the string property and did not want to modify their code. Therefore, Status was grandfathered into the Schema. Use of the Deprecated qualifier allows the maintenance of the existing property, but also permits an improved definition using OperationalStatus." ::= { mediaAccessDeviceEntry 4 } mediaAccessDevice-Availability OBJECT-TYPE SYNTAX INTEGER { unknown (0), other (1), runningFullPower (2), warning (3), inTest (4), notApplicable (5), powerOff (6), offLine (7), offDuty (8), degraded (9), notInstalled (10), installError (11), powerSaveUnknown (12), powerSaveLowPowerMode (13), powerSaveStandby (14), powerCycle (15), powerSaveWarning (16), paused (17), notReady (18) } ACCESS read-only STATUS mandatory DESCRIPTION "The primary availability and status of the Device. (Additional status information can be specified using the AdditionalAvailability array property.) For example, the Availability property indicates that the Device is running and has full power (value=3), or is in a warning (4), test (5), degraded (10) or power save state (values 13-15 and 17). Regarding the Power Save states, these are defined as follows: Value 13 ('Power Save - Unknown') indicates that the Device is known to be in a power save mode, but its exact status in this mode is unknown; 14 ('Power Save - Low Power Mode') indicates that the Device is in a power save state but still functioning, and may exhibit degraded performance; 15 ('Power Save - Standby') describes that the Device is not functioning but could be brought to full power 'quickly'; and value 17 ('Power Save - Warning') indicates that the Device is in a warning state, though also in a power save mode." ::= { mediaAccessDeviceEntry 5 } mediaAccessDevice-NeedsCleaning OBJECT-TYPE SYNTAX INTEGER { unknown (0), true (1), false (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Boolean indicating that the MediaAccessDevice needs cleaning. Whether manual or automatic cleaning is possible is indicated in the Capabilities array property. " ::= { mediaAccessDeviceEntry 6 } physicalMediaGroup OBJECT IDENTIFIER ::= { smlRoot 7 } numberOfPhysicalMedias OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the number of PhysicalMedia that are present." ::= { physicalMediaGroup 1 } physicalMediaTable OBJECT-TYPE SYNTAX SEQUENCE OF TableInfo-2 ACCESS not-accessible STATUS mandatory DESCRIPTION "The PhysicalMedia class represents any type of documentation or storage medium, such as tapes, CDROMs, etc. This class is typically used to locate and manage Removable Media (versus Media sealed with the MediaAccessDevice, as a single Package, as is the case with hard disks). However, 'sealed' Media can also be modeled using this class, where the Media would then be associated with the PhysicalPackage using the PackagedComponent relationship." ::= { physicalMediaGroup 2 } physicalMediaEntry OBJECT-TYPE SYNTAX TableInfo-2 ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry in the table contains information about a PhysicalMedia that is present in the library." INDEX { physicalMediaIndex } ::= { physicalMediaTable 1 } TableInfo-2 ::= SEQUENCE { physicalMediaIndex UINT32, physicalMediaObjectType INTEGER, physicalMedia-Removable INTEGER, physicalMedia-Replaceable INTEGER, physicalMedia-HotSwappable INTEGER, physicalMedia-Capacity UINT64, physicalMedia-MediaType INTEGER, physicalMedia-MediaDescription DisplayString, physicalMedia-CleanerMedia INTEGER, physicalMedia-DualSided INTEGER, physicalMedia-PhysicalLabel DisplayString } physicalMediaIndex OBJECT-TYPE SYNTAX UINT32 ACCESS read-only STATUS mandatory DESCRIPTION "The current index value for the PhysicalMedia." ::= { physicalMediaEntry 1 } physicalMediaObjectType OBJECT-TYPE SYNTAX INTEGER { tape (0), other (1) } ACCESS read-only STATUS mandatory DESCRIPTION "In the 2.7 CIM Schema a Type property is no longer associated with physicalMedia. The MediaType property provides more detailed information." ::= { physicalMediaEntry 2 } physicalMedia-Removable OBJECT-TYPE SYNTAX INTEGER { unknown (0), true (1), false (2) } ACCESS read-only STATUS mandatory DESCRIPTION "A PhysicalComponent is Removable if it is designed to be taken in and out of the physical container in which it is normally found, without impairing the function of the overall packaging. A Component can still be Removable if power must be 'off' in order to perform the removal. If power can be 'on' and the Component removed, then the Element is both Removable and HotSwappable. For example, an upgradeable Processor chip is Removable." ::= { physicalMediaEntry 3 } physicalMedia-Replaceable OBJECT-TYPE SYNTAX INTEGER { unknown (0), true (1), false (2) } ACCESS read-only STATUS mandatory DESCRIPTION "A PhysicalComponent is Replaceable if it is possible to replace (FRU or upgrade) the Element with a physically different one. For example, some ComputerSystems allow the main Processor chip to be upgraded to one of a higher clock rating. In this case, the Processor is said to be Replaceable. All Removable Components are inherently Replaceable." ::= { physicalMediaEntry 4 } physicalMedia-HotSwappable OBJECT-TYPE SYNTAX INTEGER { unknown (0), true (1), false (2) } ACCESS read-only STATUS mandatory DESCRIPTION "A PhysicalComponent is HotSwappable if it is possible to replace the Element with a physically different but equivalent one while the containing Package has power applied to it (ie, is 'on'). For example, a fan Component may be designed to be HotSwappable. All HotSwappable Components are inherently Removable and Replaceable." ::= { physicalMediaEntry 5 } physicalMedia-Capacity OBJECT-TYPE SYNTAX UINT64 ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes that can be read from or written to a Media. This property is not applicable to 'Hard Copy' (documentation) or cleaner Media. Data compression should not be assumed, as it would increase the value in this property. For tapes, it should be assumed that no filemarks or blank space areas are recorded on the Media." ::= { physicalMediaEntry 6 } physicalMedia-MediaType OBJECT-TYPE SYNTAX INTEGER { unknown (0), other (1), tape (2), qic (3), ait (4), dtf (5), dat (6), eightmmTape (7), nineteenmmTape (8), dlt (9), halfInchMO (10), catridgeDisk (11), jazDisk (12), zipDisk (13), syQuestDisk (14), winchesterDisk (15), cdRom (16), cdRomXA (17), cdI (18), cdRecordable (19), dvd (20), dvdRWPlus (21), dvdRAM (22), dvdROM (23), dvdVideo (24), divx (25), cdRW (26), cdDA (27), cdPlus (28), dvdRecordable (29), dvdRW (30), dvdAudio (31), dvd5 (32), dvd9 (33), dvd10 (34), dvd18 (35), moRewriteable (36), moWriteOnce (37), moLIMDOW (38), phaseChangeWO (39), phaseChangeRewriteable (40), phaseChangeDualRewriteable (41), ablativeWriteOnce (42), nearField (43), miniQic (44), travan (45), eightmmMetal (46), eightmmAdvanced (47), nctp (48), ltoUltrium (49), ltoAccelis (50), tape9Track (51), tape18Track (52), tape36Track (53), magstar3590 (54), magstarMP (55), d2Tape (56), dstSmall (57), dstMedium (58), dstLarge (59) } ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the type of the PhysicalMedia, as an enumerated integer. The MediaDescription property is used to provide more explicit definition of the Media type, whether it is pre-formatted, compatability features, etc." ::= { physicalMediaEntry 7 } physicalMedia-MediaDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Additional detail related to the MediaType enumeration. For example, if value 3 ('QIC Cartridge') is specified, this property could indicate whether the tape is wide or 1/4 inch, whether it is pre-formatted, whether it is Travan compatible, etc." ::= { physicalMediaEntry 8 } physicalMedia-CleanerMedia OBJECT-TYPE SYNTAX INTEGER { unknown (0), true (1), false (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Boolean indicating that the PhysicalMedia is used for cleaning purposes and not data storage." ::= { physicalMediaEntry 9 } physicalMedia-DualSided OBJECT-TYPE SYNTAX INTEGER { unknown (0), true (1), false (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Boolean indicating that the Media has two recording sides (TRUE) or only a single side (FALSE). Examples of dual sided Media include DVD-ROM and some optical disks. Examples of single sided Media are tapes and CD-ROM." ::= { physicalMediaEntry 10 } physicalMedia-PhysicalLabel OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "One or more strings on 'labels' on the PhysicalMedia. The format of the labels and their state (readable, unreadable, upside-down) are indicated in the LabelFormats and LabelStates array properties." ::= { physicalMediaEntry 11 } physicalPackageGroup OBJECT IDENTIFIER ::= { smlRoot 8 } numberOfPhysicalPackages OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the number of PhysicalPackages that are present." ::= { physicalPackageGroup 1 } physicalPackageTable OBJECT-TYPE SYNTAX SEQUENCE OF TableInfo-3 ACCESS not-accessible STATUS mandatory DESCRIPTION "The PhysicalPackage class represents PhysicalElements that contain or host other components. Examples are a Rack enclosure or an adapter Card. (also a tape magazine inside an auto-loader)" ::= { physicalPackageGroup 2 } physicalPackageEntry OBJECT-TYPE SYNTAX TableInfo-3 ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry in the table contains information about a PhysicalPackage that is present in the library." INDEX { physicalPackageIndex } ::= { physicalPackageTable 1 } TableInfo-3 ::= SEQUENCE { physicalPackageIndex UINT32, physicalPackage-Manufacturer DisplayString, physicalPackage-Model DisplayString, physicalPackage-SerialNumber DisplayString, physicalPackage-Realizes-MediaAccessDeviceIndex INTEGER } physicalPackageIndex OBJECT-TYPE SYNTAX UINT32 ACCESS read-only STATUS mandatory DESCRIPTION "The current index value for the PhysicalPackage." ::= { physicalPackageEntry 1 } physicalPackage-Manufacturer OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The name of the organization responsible for producing the PhysicalElement. This may be the entity from whom the Element is purchased, but this is not necessarily true. The latter information is contained in the Vendor property of CIM_Product." ::= { physicalPackageEntry 2 } physicalPackage-Model OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "The name by which the PhysicalElement is generally known." ::= { physicalPackageEntry 3 } physicalPackage-SerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "A manufacturer-allocated number used to identify the Physical Element." ::= { physicalPackageEntry 4 } physicalPackage-Realizes-MediaAccessDeviceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The index value of the the MediaAccess device that is associated with this physical package.'" ::= { physicalPackageEntry 5 } softwareElementGroup OBJECT IDENTIFIER ::= { smlRoot 9 } numberOfSoftwareElements OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This value specifies the number of SoftwareElements that are present." ::= { softwareElementGroup 1 } softwareElementTable OBJECT-TYPE SYNTAX SEQUENCE OF TableInfo-4 ACCESS not-accessible STATUS mandatory DESCRIPTION "The CIM_SoftwareElement class is used to decompose a CIM_SoftwareFeature object into a set of individually manageable or deployable parts for a particular platform. A software element's platform is uniquely identified by its underlying hardware architecture and operating system (for example Sun Solaris on Sun Sparc or Windows NT on Intel). As such, to understand the details of how the functionality of a particular software feature is provided on a particular platform, the CIM_SoftwareElement objects referenced by CIM_SoftwareFeatureSoftwareElement associations are organized in disjoint sets based on the TargetOperatingSystem property. A CIM_SoftwareElement object captures the management details of a part or component in one of four states characterized by the SoftwareElementState property. " ::= { softwareElementGroup 2 } softwareElementEntry OBJECT-TYPE SYNTAX TableInfo-4 ACCESS not-accessible STATUS mandatory DESCRIPTION "Each entry in the table contains information about a SoftwareElement that is present in the library." INDEX { softwareElementIndex } ::= { softwareElementTable 1 } TableInfo-4 ::= SEQUENCE { softwareElementIndex UINT32, softwareElement-Name DisplayString, softwareElement-Version DisplayString, softwareElement-SoftwareElementID DisplayString, softwareElement-Manufacturer DisplayString, softwareElement-BuildNumber DisplayString, softwareElement-SerialNumber DisplayString, softwareElement-CodeSet DisplayString, softwareElement-IdentificationCode DisplayString, softwareElement-LanguageEdition DisplayString, softwareElement-Associations OBJECT IDENTIFIER, softwareElement-DeviceSoftware-LogicalDeviceAssociation-ObjectT INTEGER, softwareElement-DeviceSoftware-LogicalDeviceAssociationId INTEGER } softwareElementIndex OBJECT-TYPE SYNTAX UINT32 ACCESS read-only STATUS mandatory DESCRIPTION "The current index value for the SoftwareElement." ::= { softwareElementEntry 1 } softwareElement-Name OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "The name used to identify this software element" ::= { softwareElementEntry 2 } softwareElement-Version OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "Version should be in the form .. or . " ::= { softwareElementEntry 3 } softwareElement-SoftwareElementID OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "This is an identifier for this software element and is designed to be used in conjunction with other keys to create a unique representation of this SoftwareElement" ::= { softwareElementEntry 4 } softwareElement-Manufacturer OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "Manufacturer of this software element" ::= { softwareElementEntry 5 } softwareElement-BuildNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "The internal identifier for this compilation of this software element." ::= { softwareElementEntry 6 } softwareElement-SerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "The assigned serial number of this software element." ::= { softwareElementEntry 7 } softwareElement-CodeSet OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "The code set used by this software element. " ::= { softwareElementEntry 8 } softwareElement-IdentificationCode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this property is the manufacturer's identifier for this software element. Often this will be a stock keeping unit (SKU) or a part number." ::= { softwareElementEntry 9 } softwareElement-LanguageEdition OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this property identifies the language edition of this software element. The language codes defined in ISO 639 should be used. Where the software element represents multi-lingual or international version of a product, the string multilingual should be used." ::= { softwareElementEntry 10 } softwareElement-Associations OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS not-accessible STATUS mandatory DESCRIPTION "Use this value to associate a SoftwareElement with another object in the MIB" ::= { softwareElementEntry 11 } softwareElement-DeviceSoftware-LogicalDeviceAssociation-ObjectT OBJECT-TYPE SYNTAX INTEGER { mediaAccessDevice (0), storageLibrary (1), other (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Use this value to associate a SoftwareElement with a specific media access device or the library itself." ::= { softwareElementEntry 12 } softwareElement-DeviceSoftware-LogicalDeviceAssociationId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Further clarification required." ::= { softwareElementEntry 13 } endOfSmlMib OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS not-accessible STATUS mandatory DESCRIPTION "Description here" ::= { smlRoot 10 } END