-- -- Accedian Enterprise Specific MIB: Structure of Management Information -- -- Copyright (c) 2005-2011, Accedian Networks, Inc. -- All rights reserved. -- -- The contents of this document are subject to change without notice. -- ACD-ALARM-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Unsigned32 FROM SNMPv2-SMI DisplayString, TruthValue, DateAndTime FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF sysName FROM SNMPv2-MIB acdMibs FROM ACCEDIAN-SMI; acdAlarm MODULE-IDENTITY LAST-UPDATED "201110100100Z" ORGANIZATION "Accedian Networks, Inc." CONTACT-INFO "Accedian Technical Assistance Center Accedian Networks, Inc. 4878 Levy, suite 202 Saint-Laurent, Quebec Canada H4R 2P1 E-mail: support@accedian.com" DESCRIPTION "The alarm Table for this Accedian Networks device." REVISION "201110100100Z" -- 10 October 2011 DESCRIPTION "Add acdAlarmCfgTableLastChangeTid and acdAlarmStatusTableLastChangeTid." REVISION "201011100100Z" -- 10 November 2010 DESCRIPTION "Fix compliance section." REVISION "200902040100Z" -- 4 Feb 2009 DESCRIPTION "Add new fields in acdAlarmCfgEntry, acdAlarmActiveState and acdAlarmClearState." REVISION "200802010100Z" -- 1 Feb 2008 DESCRIPTION "Add UNITS clause to object, where appropriate." REVISION "200705220100Z" -- 22 May 2007 DESCRIPTION "Add acdAlarmCfgNumber object to Alarm traps." REVISION "200612190100Z" -- 19 Dec 2006 DESCRIPTION "Add 802.3AH notification enable and msg field in status table." REVISION "200608060100Z" -- 6 Aug 2006 DESCRIPTION "Initial version of MIB module ACD-ALARM-MIB." ::= { acdMibs 1 } acdAlarmMIBObjects OBJECT IDENTIFIER ::= { acdAlarm 15 } acdAlarmConfig OBJECT IDENTIFIER ::= { acdAlarmMIBObjects 1 } acdAlarmStatus OBJECT IDENTIFIER ::= { acdAlarmMIBObjects 2 } acdAlarmConformance OBJECT IDENTIFIER ::= { acdAlarmMIBObjects 3 } acdAlarmTableTid OBJECT IDENTIFIER ::= { acdAlarmMIBObjects 4 } --------------------------------------------------------------------------- -- Alarm General configuration --------------------------------------------------------------------------- acdAlarmGenThreshOn OBJECT-TYPE SYNTAX Unsigned32 (500..50000) UNITS "milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This value represents the Alarm On Hysteris. This is the time since the detection of the On event inside the system versus the report. This is to avoid storm of notifications." ::= { acdAlarm 1 } acdAlarmGenThreshOff OBJECT-TYPE SYNTAX Unsigned32 (500..50000) UNITS "milliseconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This value represents the Alarm Off Hysteris. This is the time since the detection of the Off event inside the system versus the report. This is to avoid storm of notifications." ::= { acdAlarm 2 } acdAlarmGenLedEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is to Enable the alarms reporting through the LEDs." ::= { acdAlarm 3 } acdAlarmGenSyslogEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is to Enable the alarms reporting through the syslog system." ::= { acdAlarm 4 } acdAlarmGenSNMPEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is to Enable the alarms reporting through the SNMP agent." ::= { acdAlarm 5 } acdAlarmGen8023AHEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is to Enable the alarms reporting through the 802.3AH protocol." ::= { acdAlarm 6 } --------------------------------------------------------------------------- -- The Alarm configuration table -- This table contains the configuration for each alarm. --------------------------------------------------------------------------- acdAlarmCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF AcdAlarmCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of all alarms." ::= { acdAlarm 10 } acdAlarmCfgEntry OBJECT-TYPE SYNTAX AcdAlarmCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An alarm is an exceptional event that requires user notificaton." INDEX { acdAlarmCfgID } ::= { acdAlarmCfgTable 1 } AcdAlarmCfgEntry ::= SEQUENCE { acdAlarmCfgID Unsigned32, acdAlarmCfgNumber Unsigned32, acdAlarmCfgDesc DisplayString, acdAlarmCfgEnable TruthValue, acdAlarmCfgSeverity INTEGER, acdAlarmCfgServiceAffecting TruthValue, acdAlarmCfgExtNumber DisplayString, acdAlarmCfgConditionType DisplayString, acdAlarmCfgAMOType DisplayString } acdAlarmCfgID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unique value for each alarm. Its value ranges from 1 to MAXINT (4 bytes). " ::= { acdAlarmCfgEntry 1 } acdAlarmCfgNumber OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unique number that identifies this alarm. Assigned by the unit. The alarm identifier is compose of 3 fields, the module number, the instance number and the error number. The alarm number looks like this: A.BBB.CC and is expressed in decimal, A is the module number, BBB is the instance number (1-999) and CC is the error number (1-99). A module number is assigned for each source of alarm in the system. For example the port module is set to 1, the SFP module is set to 2, the PAA is set to 3 and the environmental is set to 8." ::= { acdAlarmCfgEntry 2 } acdAlarmCfgDesc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "This string is to describe the alarm in a readable way, e.g.: +5Vdc Power supply fail." ::= { acdAlarmCfgEntry 3 } acdAlarmCfgEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is to indicate if the alarm is reported or not." ::= { acdAlarmCfgEntry 4 } acdAlarmCfgSeverity OBJECT-TYPE SYNTAX INTEGER { info(0), minor(1), major(2), critical(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Accedian Networks classifies alarms into four severity types. These types and their associated decimal codes are, informational(0), minor(1), major(2) and critical(3)." ::= { acdAlarmCfgEntry 5 } acdAlarmCfgServiceAffecting OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is to indicate if the alarm is service affecting or not. This value depends on the utilization of the box. For instance in an application where the monitoring of the traffic is mandatory the link down event on the monitor port is service affecting." ::= { acdAlarmCfgEntry 6 } acdAlarmCfgExtNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique number that identifies this alarm. Assigned by the unit. The alarm identifier is compose of 3 fields, the module number, the instance number and the error number. The alarm number looks like this: A.B.C and is expressed in decimal, A is the module number, B is the instance number and C is the error number. A module number is assigned for each source of alarm in the system (see Accedian documentation for more detail)." ::= { acdAlarmCfgEntry 7 } acdAlarmCfgConditionType OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the type of alarm condition." ::= { acdAlarmCfgEntry 8 } acdAlarmCfgAMOType OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "This is the Alarm Maintenance Object." ::= { acdAlarmCfgEntry 9 } --------------------------------------------------------------------------- -- The Alarms Status table -- This table contains the status of all alarms. --------------------------------------------------------------------------- acdAlarmStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF AcdAlarmStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of all alarms" ::= { acdAlarm 11 } acdAlarmStatusEntry OBJECT-TYPE SYNTAX AcdAlarmStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An alarm is an exceptional event that requires user notificaton." INDEX { acdAlarmStatusID } ::= { acdAlarmStatusTable 1 } AcdAlarmStatusEntry ::= SEQUENCE { acdAlarmStatusID Unsigned32, acdAlarmStatusNumber Unsigned32, acdAlarmStatusOn TruthValue, acdAlarmStatusLastChange DateAndTime, acdAlarmStatusMsg DisplayString } acdAlarmStatusID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unique value for each alarm. Its value ranges from 1 to MAXINT (4 bytes). " ::= { acdAlarmStatusEntry 1 } acdAlarmStatusNumber OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unique number that identifies this alarm. Assigned by the unit. The alarm identifier is compose of 3 fields, the module number, the instance number and the error number. The alarm number looks like this: AAA.BBB.CC and is expressed in decimal, AAA is the module number, BBB is the instance number (1-999) and CC is the error number (1-99). A module number is assigned for each source of alarm in the system. For example the port module is set to 1, the SFP module is set to 2, the PAA is set to 3 and the environmental is set to 8." ::= { acdAlarmStatusEntry 2 } acdAlarmStatusOn OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This is to indicate if the alarm is On or Off." ::= { acdAlarmStatusEntry 3 } acdAlarmStatusLastChange OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "This is the time of the last change for this alarm. A value of zero means that nothing happened to this alarm since the last reboot." ::= { acdAlarmStatusEntry 4 } acdAlarmStatusMsg OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "This string is to add information why the alarm is reported." ::= { acdAlarmStatusEntry 5 } -- Accedian Alarm Traps --------------------------------------------------------------------------- -- DESCRIPTION "Definition point for Accedian Alarm notifications." --------------------------------------------------------------------------- acdAlarmV2 OBJECT IDENTIFIER ::= { acdAlarm 12 } acdAlarmActiveState NOTIFICATION-TYPE OBJECTS { acdAlarmCfgID, acdAlarmCfgNumber, acdAlarmCfgSeverity, acdAlarmCfgServiceAffecting, acdAlarmCfgDesc, acdAlarmStatusLastChange, acdAlarmCfgExtNumber, acdAlarmCfgConditionType, acdAlarmCfgAMOType, sysName } STATUS current DESCRIPTION "The SNMP trap that is generated when an alarm entry crosses its rising threshold and generates an event that is configured for sending SNMP traps." ::= { acdAlarmV2 1 } acdAlarmClearState NOTIFICATION-TYPE OBJECTS { acdAlarmCfgID, acdAlarmCfgNumber, acdAlarmCfgSeverity, acdAlarmCfgServiceAffecting, acdAlarmCfgDesc, acdAlarmStatusLastChange, acdAlarmCfgExtNumber, acdAlarmCfgConditionType, acdAlarmCfgAMOType, sysName } STATUS current DESCRIPTION "The SNMP trap that is generated when an alarm entry crosses its falling threshold and generates an event that is configured for sending SNMP traps." ::= { acdAlarmV2 2 } --------------------------------------------------------------------------- -- Transaction ID Information --------------------------------------------------------------------------- acdAlarmCfgTableLastChangeTid OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is the transaction ID of the last change of the acdAlarmCfgTable table. If this value is different since the last read this is indicate a table change." ::= { acdAlarmTableTid 1 } acdAlarmStatusTableLastChangeTid OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is the transaction ID of the last change of the acdAlarmStatusTable table. If this value is different since the last read this is indicate a table change." ::= { acdAlarmTableTid 2 } --------------------------------------------------------------------------- -- ACD-ALARM-MIB Module - Conformance Information --------------------------------------------------------------------------- acdAlarmCompliances OBJECT IDENTIFIER ::= { acdAlarmConformance 1 } acdAlarmGroups OBJECT IDENTIFIER ::= { acdAlarmConformance 2 } --------------------------------------------------------------------------- -- Units of conformance --------------------------------------------------------------------------- acdAlarmGenGroup OBJECT-GROUP OBJECTS { acdAlarmGenThreshOn, acdAlarmGenThreshOff, acdAlarmGenLedEnable, acdAlarmGenSyslogEnable, acdAlarmGenSNMPEnable, acdAlarmGen8023AHEnable } STATUS current DESCRIPTION "." ::= { acdAlarmGroups 1 } acdAlarmCfgGroup OBJECT-GROUP OBJECTS { acdAlarmCfgID, acdAlarmCfgNumber, acdAlarmCfgDesc, acdAlarmCfgEnable, acdAlarmCfgSeverity, acdAlarmCfgServiceAffecting, acdAlarmCfgExtNumber, acdAlarmCfgConditionType, acdAlarmCfgAMOType } STATUS current DESCRIPTION "." ::= { acdAlarmGroups 2 } acdAlarmStatusGroup OBJECT-GROUP OBJECTS { acdAlarmStatusID, acdAlarmStatusNumber, acdAlarmStatusOn, acdAlarmStatusLastChange, acdAlarmStatusMsg } STATUS current DESCRIPTION "." ::= { acdAlarmGroups 3 } acdAlarmNotificationsGroup NOTIFICATION-GROUP NOTIFICATIONS { acdAlarmActiveState, acdAlarmClearState } STATUS current DESCRIPTION "Objects for the Notifications group." ::= { acdAlarmGroups 4 } acdAlarmTidGroup OBJECT-GROUP OBJECTS { acdAlarmCfgTableLastChangeTid, acdAlarmStatusTableLastChangeTid } STATUS current DESCRIPTION "List of scalars to monitior changes in tables." ::= { acdAlarmGroups 5 } --------------------------------------------------------------------------- -- MIB Module Compliance statements --------------------------------------------------------------------------- acdAlarmCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for support of the ACD-ALARM-MIB module." MODULE MANDATORY-GROUPS { acdAlarmGenGroup, acdAlarmCfgGroup, acdAlarmStatusGroup, acdAlarmNotificationsGroup, acdAlarmTidGroup } ::= { acdAlarmCompliances 1 } END