ADTRAN-AOS-MUX-MIB DEFINITIONS ::= BEGIN -- TITLE: THE ADTRAN OPERATING SYSTEM MULTIPLEXING MIB -- FILENAME: AdGenAOSMux.mib -- AUTHOR: Jason Schock -- DATE: 10/15/04 -- HISTORY -- 10/15/04 First draft. IMPORTS OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI RowStatus FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF adIdentity FROM ADTRAN-MIB adGenAOSCommon, adGenAOSConformance FROM ADTRAN-AOS; adGenAOSMuxID MODULE-IDENTITY LAST-UPDATED "200410150000Z" ORGANIZATION "ADTRAN, Inc." CONTACT-INFO "Technical Support Dept. Postal: ADTRAN, Inc. 901 Explorer Blvd. Huntsville, AL 35806 Tel: +1 800 726-8663 Fax: +1 256 963 6217 E-mail: support@adtran.com" DESCRIPTION "The MIB module for the management of AOS products with TDM multiplexing and/or cross-connects." ::= { adIdentity 10000 53 1 5 } -- OBJECT IDENTIFIERS adGenAOSMux OBJECT IDENTIFIER ::= { adGenAOSCommon 5 } adGenAOSXConnect OBJECT IDENTIFIER ::= { adGenAOSMux 1 } adGenAOSTdmGroup OBJECT IDENTIFIER ::= { adGenAOSMux 2 } adGenAOSMuxConformance OBJECT IDENTIFIER ::= { adGenAOSMux 99 } adGenAOSMuxCompliance OBJECT IDENTIFIER ::= { adGenAOSMuxConformance 1 } adGenAOSMuxMibGroups OBJECT IDENTIFIER ::= { adGenAOSMuxConformance 2 } -- -- XConnect Configuration Table -- adGenAOSXConnectTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenAOSXConnectEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Cross-Connect Configuration Table" ::= { adGenAOSXConnect 1 } adGenAOSXConnectEntry OBJECT-TYPE SYNTAX AdGenAOSXConnectEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Cross-Connect Configuration Table" INDEX{ adGenAOSXConnectIndex } ::= { adGenAOSXConnectTable 1 } AdGenAOSXConnectEntry ::= SEQUENCE { adGenAOSXConnectIndex INTEGER, adGenAOSXConnectFirstIfType INTEGER, adGenAOSXConnectFirstIfNumber INTEGER, adGenAOSXConnectFirstSubIfNumber INTEGER, adGenAOSXConnectFirstIfSlot INTEGER, adGenAOSXConnectFirstIfPort INTEGER, adGenAOSXConnectFirstTdmGroup INTEGER, adGenAOSXConnectFirstTdmGroupDS0 INTEGER, adGenAOSXConnectSecondIfType INTEGER, adGenAOSXConnectSecondIfNumber INTEGER, adGenAOSXConnectSecondSubIfNumber INTEGER, adGenAOSXConnectSecondIfSlot INTEGER, adGenAOSXConnectSecondIfPort INTEGER, adGenAOSXConnectSecondTdmGroup INTEGER, adGenAOSXConnectSecondTdmGroupDS0 INTEGER, adGenAOSXConnectPreserveRbs INTEGER, adGenAOSXConnectRowStatus RowStatus } adGenAOSXConnectIndex OBJECT-TYPE SYNTAX INTEGER (1..1024) MAX-ACCESS read-create STATUS current DESCRIPTION "A number that uniquely defines the cross-connect" ::= { adGenAOSXConnectEntry 1 } adGenAOSXConnectFirstIfType OBJECT-TYPE SYNTAX INTEGER { notAssigned(0), dds(1), -- from only t1E1(2), -- from/to eth(3), -- from only serial(4), -- from/to shdsl(5), -- from only fxs(6), -- to only frameRelay(7), -- from/to ppp(8) -- to only } MAX-ACCESS read-create STATUS current DESCRIPTION "The type of interface from which a cross-connect is being made" ::= { adGenAOSXConnectEntry 2 } adGenAOSXConnectFirstIfNumber OBJECT-TYPE SYNTAX INTEGER (0..1024) MAX-ACCESS read-create STATUS current DESCRIPTION "A number that defines the interface described by adGenAOSXConnectFirstIfType -- set to 0 if the interface can be defined by adGenAOSXConnectFirstIfSlot and adGenAOSXConnectFirstIfPort" ::= { adGenAOSXConnectEntry 3 } adGenAOSXConnectFirstSubIfNumber OBJECT-TYPE SYNTAX INTEGER (0..1007) MAX-ACCESS read-create STATUS current DESCRIPTION "A number that further defines some interfaces -- set to 0 if the interface can be defined by adGenAOSXConnectFirstIfSlot and adGenAOSXConnectFirstIfPort" ::= { adGenAOSXConnectEntry 4 } adGenAOSXConnectFirstIfSlot OBJECT-TYPE SYNTAX INTEGER (0..96) MAX-ACCESS read-create STATUS current DESCRIPTION "The slot number containing the interface described by adGenAOSXConnectFirstIfType -- set to 0 if the interface can be defined by adGenAOSXConnectFirstIfNumber (and adGenAOSXConnectFirstSubIfNumber) Note: 0 is also a valid slot number." ::= { adGenAOSXConnectEntry 5 } adGenAOSXConnectFirstIfPort OBJECT-TYPE SYNTAX INTEGER (0..48) MAX-ACCESS read-create STATUS current DESCRIPTION "The port number of the interface described by adGenAOSXConnectFirstIfType -- set to 0 if the interface can be defined by adGenAOSXConnectFirstIfNumber (and adGenAOSXConnectFirstSubIfNumber)" ::= { adGenAOSXConnectEntry 6 } adGenAOSXConnectFirstTdmGroup OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-create STATUS current DESCRIPTION "A number uniquely identifying the TDM Group associated with the interface described by adGenAOSXConnectFirstIfType -- set to 0 if it is not necessary that a TDM Group be associated with the interface" ::= { adGenAOSXConnectEntry 7 } adGenAOSXConnectFirstTdmGroupDS0 OBJECT-TYPE SYNTAX INTEGER (0..32) MAX-ACCESS read-create STATUS current DESCRIPTION "The specific DS0 of the TDM Group, described by adGenAOSXConnectFirstTdmGroup, from which a cross- connect is being made -- set to 0 if it is not necessary that a specific timeslot be defined" ::= { adGenAOSXConnectEntry 8 } adGenAOSXConnectSecondIfType OBJECT-TYPE SYNTAX INTEGER { notAssigned(0), dds(1), -- from only t1E1(2), -- from/to eth(3), -- from only serial(4), -- from/to shdsl(5), -- from only fxs(6), -- to only frameRelay(7), -- from/to ppp(8) -- to only } MAX-ACCESS read-create STATUS current DESCRIPTION "The type of interface to which a cross-connect is being made" ::= { adGenAOSXConnectEntry 9 } adGenAOSXConnectSecondIfNumber OBJECT-TYPE SYNTAX INTEGER (0..1024) MAX-ACCESS read-create STATUS current DESCRIPTION "A number that defines the interface described by adGenAOSXConnectSecondIfType -- set to 0 if the interface can be defined by adGenAOSXConnectSecondIfSlot and adGenAOSXConnectSecondIfPort" ::= { adGenAOSXConnectEntry 10 } adGenAOSXConnectSecondSubIfNumber OBJECT-TYPE SYNTAX INTEGER (0..1007) MAX-ACCESS read-create STATUS current DESCRIPTION "A number that further defines some interfaces -- set to 0 if the interface can be defined by adGenAOSXConnectSecondIfSlot and adGenAOSXConnectSecondIfPort" ::= { adGenAOSXConnectEntry 11 } adGenAOSXConnectSecondIfSlot OBJECT-TYPE SYNTAX INTEGER (0..96) MAX-ACCESS read-create STATUS current DESCRIPTION "The slot number containing the interface described by adGenAOSXConnectSecondIfType -- set to 0 if the interface can be defined by adGenAOSXConnectSecondIfNumber (and adGenAOSXConnectSecondSubIfNumber) Note: 0 is also a valid slot number." ::= { adGenAOSXConnectEntry 12 } adGenAOSXConnectSecondIfPort OBJECT-TYPE SYNTAX INTEGER (0..48) MAX-ACCESS read-create STATUS current DESCRIPTION "The port number of the interface described by adGenAOSXConnectSecondIfType -- set to 0 if the interface can be defined by adGenAOSXConnectSecondIfNumber (and adGenAOSXConnectSecondSubIfNumber)" ::= { adGenAOSXConnectEntry 13 } adGenAOSXConnectSecondTdmGroup OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-create STATUS current DESCRIPTION "A number uniquely identifying the TDM Group associated with the interface described by adGenAOSXConnectSecondIfType -- set to 0 if it is not necessary that a TDM Group be associated with the interface" ::= { adGenAOSXConnectEntry 14 } adGenAOSXConnectSecondTdmGroupDS0 OBJECT-TYPE SYNTAX INTEGER (0..32) MAX-ACCESS read-create STATUS current DESCRIPTION "The specific DS0 of the TDM Group, described by adGenAOSXConnectSecondTdmGroup, to which a cross- connect is being made -- set to 0 if it is not necessary that a specific timeslot be defined" ::= { adGenAOSXConnectEntry 15 } adGenAOSXConnectPreserveRbs OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "The ability of the cross-connect to maintain robbed-bit signaling integrity -- set to disabled if robbed-bit signaling is not a characteristic of the cross-connect." ::= { adGenAOSXConnectEntry 16 } adGenAOSXConnectRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this conceptual row. Until instances of appropriate corresponding columns are configured, the value of the corresponding instance of the adGenAOSXConnectStatus column is 'notReady'." ::= { adGenAOSXConnectEntry 17 } -- -- TDM Group Configuration Table -- adGenAOSTdmGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF AdGenAOSTdmGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The TDM Group Table that associates DS0s into mappable units" ::= { adGenAOSTdmGroup 1 } adGenAOSTdmGroupEntry OBJECT-TYPE SYNTAX AdGenAOSTdmGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the TDM Group Table" INDEX{ adGenAOSTdmGroupIfSlot, adGenAOSTdmGroupIfPort, adGenAOSTdmGroupID } ::= { adGenAOSTdmGroupTable 1 } AdGenAOSTdmGroupEntry ::= SEQUENCE { adGenAOSTdmGroupIfSlot INTEGER, adGenAOSTdmGroupIfPort INTEGER, adGenAOSTdmGroupID INTEGER, adGenAOSTdmGroupMask INTEGER, adGenAOSTdmGroupUsage INTEGER } adGenAOSTdmGroupIfSlot OBJECT-TYPE SYNTAX INTEGER (0..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The slot number containing the interface for the TDM Group" ::= { adGenAOSTdmGroupEntry 1 } adGenAOSTdmGroupIfPort OBJECT-TYPE SYNTAX INTEGER (0..48) MAX-ACCESS read-only STATUS current DESCRIPTION "The port number containing the interface for the TDM Group" ::= { adGenAOSTdmGroupEntry 2 } adGenAOSTdmGroupID OBJECT-TYPE SYNTAX INTEGER (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "A number that uniquely defines the TDM Group" ::= { adGenAOSTdmGroupEntry 3 } adGenAOSTdmGroupMask OBJECT-TYPE SYNTAX INTEGER (-2147483648..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "A bitmap of the contiguous DS0s included in this TDM Group Example: mapping DS0s 1-12: 00000000000000000000111111111111 (bin), 00000FFF (hex), 4095 (dec) Note: To create a new row in adGenAOSTdmGroupTable, set adGenAOSTdmGroupMask with the appropriate index values corresponding to the desired slot, port, and TDM group ID" ::= { adGenAOSTdmGroupEntry 4 } adGenAOSTdmGroupUsage OBJECT-TYPE SYNTAX INTEGER { fiftySixKbps(1), sixtyFourKbps(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The speed of the individual DS0s" ::= { adGenAOSTdmGroupEntry 5 } -- -- Compliance Statements -- adGenAOSMuxConformancemModule MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for SNMPv2 entities which implement the adGenAOSMux MIB." MODULE MANDATORY-GROUPS { adGenAOSXConnectGrp, adGenAOSTdmGroupGrp } ::= { adGenAOSMuxCompliance 1 } -- units of conformance adGenAOSXConnectGrp OBJECT-GROUP OBJECTS { adGenAOSXConnectIndex, adGenAOSXConnectFirstIfType, adGenAOSXConnectFirstIfNumber, adGenAOSXConnectFirstSubIfNumber, adGenAOSXConnectFirstIfSlot, adGenAOSXConnectFirstIfPort, adGenAOSXConnectFirstTdmGroup, adGenAOSXConnectFirstTdmGroupDS0, adGenAOSXConnectSecondIfType, adGenAOSXConnectSecondIfNumber, adGenAOSXConnectSecondSubIfNumber, adGenAOSXConnectSecondIfSlot, adGenAOSXConnectSecondIfPort, adGenAOSXConnectSecondTdmGroup, adGenAOSXConnectSecondTdmGroupDS0, adGenAOSXConnectPreserveRbs, adGenAOSXConnectRowStatus } STATUS current DESCRIPTION "The Cross-Connect Group." ::= { adGenAOSMuxMibGroups 1 } adGenAOSTdmGroupGrp OBJECT-GROUP OBJECTS { adGenAOSTdmGroupIfSlot, adGenAOSTdmGroupIfPort, adGenAOSTdmGroupID, adGenAOSTdmGroupMask, adGenAOSTdmGroupUsage } STATUS current DESCRIPTION "The TDM Group Group." ::= { adGenAOSMuxMibGroups 2 } END