ADTRAN-AOSUNIT DEFINITIONS ::= BEGIN IMPORTS Integer32, Gauge32, OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI DisplayString, RowStatus, TDomain, TAddress, TEXTUAL-CONVENTION FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF adIdentity FROM ADTRAN-MIB adGenAOSCommon, adGenAOSConformance FROM ADTRAN-AOS; adGenAOSUnitMib MODULE-IDENTITY LAST-UPDATED "200409240000Z" -- September 24, 2004 ORGANIZATION "ADTRAN, Inc." CONTACT-INFO "Technical Support Dept. Postal: ADTRAN, Inc. 901 Explorer Blvd. Huntsville, AL 35806 Tel: +1 800 726-8663 Fax: +1 256 963 6217 E-mail: support@adtran.com" DESCRIPTION "This MIB contains device information, contact information, and overall system health information." REVISION "200409280000Z" -- September 28, 2004 DESCRIPTION "Initial version of this MIB module." REVISION "200505120000Z" -- May 12, 2005 DESCRIPTION "Added OIDs for primary and backup image name and part number" REVISION "200807300000Z" -- July 30, 2008 DESCRIPTION "Changed syntax range for adAOSBootRevision because the revision string length has increased. This change will maintain compatibility with older revisions." REVISION "201004090000Z" -- April 9, 2010 DESCRIPTION "Changed the syntax size for adAOSCurrentImage. The syntax size now includes a range." ::= { adIdentity 10000 53 1 1 } adGenAOSUnit OBJECT IDENTIFIER ::= { adGenAOSCommon 1 } -- ======================================================================== -- Textual Conventions for this MIB Utf8String ::= TEXTUAL-CONVENTION DISPLAY-HINT "255a" STATUS current DESCRIPTION "To facilitate internationalization, this TC represents information taken from the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 character encoding scheme described in RFC 2044 [10]. For strings in 7-bit US-ASCII, there is no impact since the UTF-8 representation is identical to the US-ASCII encoding." SYNTAX OCTET STRING (SIZE (0..255)) -- ======================================================================== adAOSBootRevision OBJECT-TYPE SYNTAX DisplayString (SIZE(3..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Unit boot PROM revision." ::= { adGenAOSUnit 1 } adAOSCurrentImage OBJECT-TYPE SYNTAX DisplayString (SIZE(0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Filename for current firmware image." ::= { adGenAOSUnit 2 } adAOSRunConfigChecksum OBJECT-TYPE SYNTAX DisplayString (SIZE(32)) MAX-ACCESS read-only STATUS current DESCRIPTION "MD5 Digest of the running configuration" ::= { adGenAOSUnit 3 } adAOSStartConfigChecksum OBJECT-TYPE SYNTAX DisplayString (SIZE(32)) MAX-ACCESS read-only STATUS current DESCRIPTION "MD5 Digest of the startup configuration" ::= { adGenAOSUnit 4 } adAOSDeviceIndex OBJECT-TYPE SYNTAX INTEGER (0..1000) MAX-ACCESS read-only STATUS current DESCRIPTION "The unique device identification within the instance of this Mib." ::= { adGenAOSUnit 5 } adAOSDeviceGlobalUniqueID OBJECT-TYPE SYNTAX Utf8String MAX-ACCESS read-only STATUS current DESCRIPTION "This represents a globally unique ID for the device. This MUST be the ordered combination of the Manufacturer, product name, AND any other text that is necessary to guarantee global uniqueness. This value may not be null. Could use serial number. e.g. AD123456789" ::= { adGenAOSUnit 6 } adAOSDeviceHealth OBJECT-TYPE SYNTAX INTEGER { unknown (1), unused (2), ok (3), -- available for meaningful work warning (4), -- something needs attention critical (5), -- something has failed nonrecoverable (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Overall health of the device. The goal of this object is to be the single poll point to check the status of the device." ::= { adGenAOSUnit 7 } adAOSDeviceSysObjID OBJECT-TYPE SYNTAX Utf8String MAX-ACCESS read-only STATUS current DESCRIPTION "System Object ID for this Device entity. This should be an ASCII integer format. (i.e. 1.3.6.1.4.1.11.2.36.1.1) The value may not be null." -- -- NOTE: For single device agents this field contains a value -- similar to the MIB II/System/sysObjID -- ::= { adGenAOSUnit 8 } adAOSDeviceManagementURL OBJECT-TYPE SYNTAX Utf8String MAX-ACCESS read-write STATUS current DESCRIPTION "This object contains the URL for the device's management software. If it does not exist the value is empty string. If write is not supported, then return invalid. This value is retained across boots." ::= { adGenAOSUnit 9 } adAOSDeviceManagementURLLabel OBJECT-TYPE SYNTAX Utf8String MAX-ACCESS read-write STATUS current DESCRIPTION "The label that a management application should use for the hyperlink to the entity's URL." ::= { adGenAOSUnit 10 } adAOSDeviceManufacturer OBJECT-TYPE SYNTAX Utf8String MAX-ACCESS read-only STATUS current DESCRIPTION "The device's manufacturer name. Will return 'ADTRAN' " ::= { adGenAOSUnit 11 } adAOSDeviceProductName OBJECT-TYPE SYNTAX Utf8String MAX-ACCESS read-only STATUS current DESCRIPTION "The device's product name. Null is NOT a valid value. (i.e. D1234A)" ::= { adGenAOSUnit 12 } adAOSDeviceSerialNumber OBJECT-TYPE SYNTAX Utf8String MAX-ACCESS read-only STATUS current DESCRIPTION "The serial number for the device. This can return a NULL string." ::= { adGenAOSUnit 13 } adAOSDeviceVersion OBJECT-TYPE SYNTAX Utf8String (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Version number for this device." ::= { adGenAOSUnit 14 } adAOSDeviceHWVersion OBJECT-TYPE SYNTAX Utf8String (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Version number for this device's hardware." ::= { adGenAOSUnit 15 } adAOSDeviceContactPerson OBJECT-TYPE SYNTAX Utf8String MAX-ACCESS read-write STATUS current DESCRIPTION "Identifies the name of the person responsible for the operation of this device. If write is not supported then return invalid." -- -- NOTE: For single device agents this field contains a value -- similar to the MIB II/System/sysContact -- ::= { adGenAOSUnit 16 } adAOSDeviceContactPhone OBJECT-TYPE SYNTAX Utf8String (SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "Phone number of the contact person for this device." ::= { adGenAOSUnit 17 } adAOSDeviceContactEmail OBJECT-TYPE SYNTAX Utf8String MAX-ACCESS read-write STATUS current DESCRIPTION "e-mail address of the contact person for this device." ::= { adGenAOSUnit 18 } adAOSDeviceContactPagerNumber OBJECT-TYPE SYNTAX Utf8String (SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "Pager number of the contact person for this device." ::= { adGenAOSUnit 19 } adAOSDeviceLocation OBJECT-TYPE SYNTAX Utf8String MAX-ACCESS read-write STATUS current DESCRIPTION "Identifies the location for the this device. If write is not supported then return invalid." -- -- NOTE: For single device agents this field contains a value -- similar to the MIB II/System/sysLocation -- ::= { adGenAOSUnit 20 } adGenAOSSaveConfig OBJECT-TYPE SYNTAX INTEGER { saveconfig (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set value to 1 to copy running config to startup config." ::= { adGenAOSUnit 21 } adGenAOSReloadSystem OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "Set to 0 to initiate immediate system reload. Any non-zero value is the number of seconds until reload" DEFVAL { 0 } ::= { adGenAOSUnit 22 } adGenAOSCancelReload OBJECT-TYPE SYNTAX INTEGER { cancelreload (1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Writing any value to this element will cancel a scheduled reload" ::= { adGenAOSUnit 23 } adAOSPrimaryImage OBJECT-TYPE SYNTAX DisplayString (SIZE(0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "Filename for primary firmware image." ::= { adGenAOSUnit 24 } adAOSBackupImage OBJECT-TYPE SYNTAX DisplayString (SIZE(0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "Filename for backup firmware image." ::= { adGenAOSUnit 25 } adAOSDevicePartNumber OBJECT-TYPE SYNTAX Utf8String MAX-ACCESS read-only STATUS current DESCRIPTION "The device's part number. Null is NOT a valid value. (i.e. 1202860L1)" ::= { adGenAOSUnit 26 } -- conformance information adGenAOSUnitConformance OBJECT IDENTIFIER ::= { adGenAOSConformance 1 } adAOSUnitCompliances OBJECT IDENTIFIER ::= { adGenAOSUnitConformance 1 } adAOSUnitGroups OBJECT IDENTIFIER ::= { adGenAOSUnitConformance 2 } adAOSCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for SNMPv2 entities which implement the AOS Unit MIB." MODULE MANDATORY-GROUPS { adGenAOSUnitGroup } ::= { adAOSUnitCompliances 1 } -- compliance statements -- units of conformance adGenAOSUnitGroup OBJECT-GROUP OBJECTS { adAOSBootRevision, adAOSCurrentImage, adAOSRunConfigChecksum, adAOSStartConfigChecksum, adAOSDeviceIndex, adAOSDeviceGlobalUniqueID, adAOSDeviceHealth, adAOSDeviceSysObjID, adAOSDeviceManagementURL, adAOSDeviceManufacturer, adAOSDeviceProductName, adAOSDeviceSerialNumber, adAOSDeviceVersion, adAOSDeviceHWVersion, adAOSDeviceContactPerson, adAOSDeviceContactPhone, adAOSDeviceContactEmail, adAOSDeviceContactPagerNumber, adAOSDeviceLocation, adGenAOSSaveConfig, adGenAOSReloadSystem, adGenAOSCancelReload, adAOSPrimaryImage, adAOSBackupImage, adAOSDevicePartNumber } STATUS current DESCRIPTION "The Unit SNMP Config Group." ::= { adAOSUnitGroups 1 } END