-- ***************************************************************** -- ADVANTECH-COMMON-MIB: Advantech Industrial Common MIB -- -- Jan 2015, Embedded Software -- -- Copyright (c) 2015 by Advantech eAutomation Group, Inc. -- All rights reserved. -- **************************************************************** ADVANTECH-COMMON-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, enterprises, OBJECT-TYPE, Integer32, IpAddress, TimeTicks FROM SNMPv2-SMI -- RFC2578 OBJECT-GROUP FROM SNMPv2-CONF DisplayString, DateAndTime FROM SNMPv2-TC-v1 SnmpAdminString FROM SNMP-FRAMEWORK-MIB -- RFC2279 ; advantech OBJECT IDENTIFIER ::= { enterprises 10297 } advantechCommonMIB MODULE-IDENTITY LAST-UPDATED "201501060000Z" ORGANIZATION "Advantech eAutomation Group" CONTACT-INFO " Advantech eAutomation Embedded Software E-mail: support@advantech.com Campion.Kang@advantech.com.tw" DESCRIPTION "The MIB module is for Advantech automation devices common entities. Copyright (C) 2015 Advantech Automation Group. " -- * Revision history REVISION "201305250000Z" DESCRIPTION "Initial version of the Advantech Common MIB. " REVISION "201308280000Z" DESCRIPTION "Fixed the worng id of psIRQ, psState, psModuleType and psModulePorts in pciConfigObj " REVISION "201308290000Z" DESCRIPTION "Update the Size of psBaseAddress to 32." REVISION "201309060000Z" DESCRIPTION "1. Update the Size of psBaseAddress to 80(8x10). 2. Add psLength (pciSlotEntry 15). 3. Fixed wrong snmpTrapVersion enumeration from enable(1), disabled(2) to v1(1), v2c(2), v3(3)." REVISION "201410130000Z" DESCRIPTION "Add DateAndTime specification in the description of the oid which is DateAndTime type." REVISION "201410220000Z" DESCRIPTION "To support ManageEngine MibBrowser Free Tool" REVISION "201501060000Z" DESCRIPTION "Change psDisplayName, psDescr, psManufacturer, psLocation to SnmpAdminString to support UTF-8 string." ::= { advantech 100 } atSystem OBJECT IDENTIFIER ::= {advantechCommonMIB 1} atMgmt OBJECT IDENTIFIER ::= {advantechCommonMIB 2} atPciConfig OBJECT IDENTIFIER ::= {advantechCommonMIB 3} -- *************************************************************************** -- atSystem group -- a collection of objects common to all Advantech managed systems. -- -- Implementation of the Advantech Common System group is mandatory -- for all systems. If an agent is not configured to have a value -- for any of these variables, a string of length 0 is -- returned. -- *************************************************************************** sysModuleID OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The module name of the device. This value should include the full name of the hardware. It is mandatory that this only contain printable ASCII characters. e.g. UNO-2184G, TPC-1840WP. etc,. " ::= { atSystem 1 } sysDeviceName OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS current DESCRIPTION "The user defined name of the device, e.g. alias name, may be its device location." ::= { atSystem 2 } sysDescr OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS current DESCRIPTION "A textual description of the entity/device that this only contain printable ASCII characters." ::= { atSystem 3 } sysImageVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "The release version number of the entity/device." ::= { atSystem 4 } sysReleaseDate OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..32)) ACCESS read-only STATUS mandatory DESCRIPTION "The release date of the entity/device." ::= { atSystem 5 } sysFirstBootTime OBJECT-TYPE SYNTAX DateAndTime ACCESS read-only STATUS mandatory DESCRIPTION "The first boot time since the entity/device was started it will be reset if the device cleaned all files and registry with clean boot. A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC 0..11 10 11 minutes from UTC 0..59 If this information is not known, then this variable shall have the value corresponding to January 1, year 0000, 00:00:00.0, which is encoded as (hex)'00 00 01 01 00 00 00 00'." ::= { atSystem 6 } sysBootTime OBJECT-TYPE SYNTAX DateAndTime ACCESS read-only STATUS mandatory DESCRIPTION "The time since the entity/device was last re-initialized. A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC 0..11 10 11 minutes from UTC 0..59 If this information is not known, then this variable shall have the value corresponding to January 1, year 0000, 00:00:00.0, which is encoded as (hex)'00 00 01 01 00 00 00 00'." ::= { atSystem 7 } sysBootCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The boot count since the entity/device was first boot." ::= { atSystem 8 } -- *************************************************************************** -- atMgmt group -- A collection of objects for Advantech Common Management -- configuration. -- *************************************************************************** snmpTrapSrvObj OBJECT IDENTIFIER ::= { atMgmt 1 } snmpTrapSrvNumber OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS mandatory DESCRIPTION "The number of the snmpTrapSrvTable" ::= { snmpTrapSrvObj 1 } snmpTrapSrvTable OBJECT-TYPE SYNTAX SEQUENCE OF SnmpTrapSrvEntry MAX-ACCESS not-accessible STATUS mandatory DESCRIPTION "The (conceptual) table listing the information of the remote SNMP Trap server acting as a trap receiver." ::= { snmpTrapSrvObj 2 } snmpTrapSrvEntry OBJECT-TYPE SYNTAX SnmpTrapSrvEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "SNMP Trap server entry. Contains the IP address of a SNMP Trap server" INDEX { snmpTrapSrvIndex } ::= { snmpTrapSrvTable 1 } SnmpTrapSrvEntry ::= SEQUENCE { snmpTrapSrvIndex INTEGER, snmpTrapSrvIP IpAddress, snmpTrapSrvPort INTEGER, snmpTrapSrvAuthentication INTEGER, snmpTrapSrvCommunity DisplayString, snmpTrapVersion INTEGER } snmpTrapSrvIndex OBJECT-TYPE SYNTAX INTEGER (1..256) ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the index of the table being a unique value for each entry." ::= { snmpTrapSrvEntry 1 } snmpTrapSrvIP OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "This parameter specifies the IP address of the SNMP Trap Server." ::= { snmpTrapSrvEntry 2 } snmpTrapSrvPort OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "The port number for the SNMP Trap Server." ::= { snmpTrapSrvEntry 3 } snmpTrapSrvAuthentication OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter enables authentication traps." ::= { snmpTrapSrvEntry 4 } snmpTrapSrvCommunity OBJECT-TYPE SYNTAX DisplayString (SIZE (1..256)) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter specifies the SNMP community." ::= { snmpTrapSrvEntry 5 } snmpTrapVersion OBJECT-TYPE SYNTAX INTEGER { v1(1), v2c(2), v3(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter specifies the SNMP trap version." ::= { snmpTrapSrvEntry 6 } -- *************************************************************************** -- atPciConfig Group -- The atPciConfig group provides a set of tables that details the -- configuration information regarding the PCI configuration. -- Implementation of the atPciConfig group is optional. -- The atPciConfig group should be included on any system/device with -- an PCI bus architecture. -- *************************************************************************** pciConfigObj OBJECT IDENTIFIER ::= { atPciConfig 1 } psNumber OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS current DESCRIPTION "The number of the psTable" ::= { pciConfigObj 1 } pciSlotTable OBJECT-TYPE SYNTAX SEQUENCE OF PCISlotEntry ACCESS not-accessible STATUS current DESCRIPTION "A list of PCI device/functions entries." ::= {pciConfigObj 2} pciSlotEntry OBJECT-TYPE SYNTAX PCISlotEntry ACCESS not-accessible STATUS current DESCRIPTION "PCI slot entry. Contains the information of PCI devices." INDEX {psIndex} ::= {pciSlotTable 1} PCISlotEntry ::= SEQUENCE { psIndex INTEGER, psBusIndex INTEGER, psDeviceIndex INTEGER, psFunctionIndex INTEGER, psDisplayName SnmpAdminString, psDescr SnmpAdminString, psVendorID INTEGER, psDeviceID INTEGER, psSubsysVendorID INTEGER, psSubsysDeviceID INTEGER, psClassCode OCTET STRING, psManufacturer SnmpAdminString, psLocation SnmpAdminString, psBaseAddress OCTET STRING, psLength OCTET STRING, psIRQ INTEGER, psState INTEGER, psModuleType INTEGER, psModulePorts Integer32 } psIndex OBJECT-TYPE SYNTAX INTEGER (1..256) ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the index of the table being a unique value for each entry." ::= { pciSlotEntry 1 } psBusIndex OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The PCI Bus number" ::= {pciSlotEntry 2} psDeviceIndex OBJECT-TYPE SYNTAX INTEGER (0..31) ACCESS read-only STATUS mandatory DESCRIPTION "The PCI device or slot number that this entry describes." ::= {pciSlotEntry 3} psFunctionIndex OBJECT-TYPE SYNTAX INTEGER (0..7) ACCESS read-only STATUS mandatory DESCRIPTION "The PCI function number that this entry describes." ::= {pciSlotEntry 4} psDisplayName OBJECT-TYPE SYNTAX SnmpAdminString ACCESS read-only STATUS mandatory DESCRIPTION "Service name of the PCI device. e.g. Intel 82579LM Gigabit Network Connection" ::= {pciSlotEntry 5} psDescr OBJECT-TYPE SYNTAX SnmpAdminString ACCESS read-only STATUS mandatory DESCRIPTION "PCI device description" ::= {pciSlotEntry 6} psVendorID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the manufacturer of the device. 65535(0xFFFF) is an invalid value for a vendor ID. Vendor ID Manufacturer ------------- ------------ 5118(0x13FE) Advantech Co." ::= {pciSlotEntry 7} psDeviceID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the particular device. This identier is allocated by the vendor. The following is the Advantech PCI Device ID. Device ID Description ------------- ----------------------- 49154(0xC002) CAN 2 Ports(I/O) 49666(0xC202) CAN 2 Ports(memory) 49410(0xC102) CANopen 2 ports(I/O) 49666(0xC202) CANopen 2 ports(memory) 4097(0x1001) NVRAM 40964(0xA004) COM950 4 Ports 61952(0xF200) PCIe 2 COM950 Ports 62208(0xF300) PCIe 4 COM950 Ports 62464(0xF400) PCIe 8 COM950 Ports 43041(0xA821) PCIe 1 COM17V25x Port 43042(0xA822) PCIe 2 COM17V25x Ports 43043(0xA823) PCIe 3 COM17V25x Ports 43044(0xA824) PCIe 4 COM17V25x Ports 43048(0xA828) PCIe 8 COM17V25x Ports 43057(0xA831) PCIe 1 COM17V35x Port 43058(0xA832) PCIe 2 COM17V35x Ports 43059(0xA833) PCIe 3 COM17V35x Ports 43060(0xA834) PCIe 4 COM17V35x Ports 43064(0xA838) PCIe 8 COM17V35x Ports " ::= {pciSlotEntry 8} psSubsysVendorID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the manufacturer subsystem of the device. 65535(0xFFFF) is an invalid value for a vendor ID. Subsys Vendor ID Manufacturer ---------------- ------------ 5118(0x13FE) Advantech Co." ::= {pciSlotEntry 9} psSubsysDeviceID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the particular device subsystem. This identier is allocated by the vendor. Subsystem Device ID Description ------------------- -------------------------------------- 4097(0x1001) NVRAM with KW 4113(0x1011) NVRAM without KW " ::= {pciSlotEntry 10} psClassCode OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-only STATUS mandatory DESCRIPTION "Identifies the generic function of the device. Base Sub- Prog Class Class If. Description ------ ------ ------ -------------------------------------- 00h Device was built before Class Code definitions were finalized " ::= {pciSlotEntry 11} psManufacturer OBJECT-TYPE SYNTAX SnmpAdminString ACCESS read-only STATUS current DESCRIPTION "The manufacturer name of the PCI device" ::= {pciSlotEntry 12} psLocation OBJECT-TYPE SYNTAX SnmpAdminString ACCESS read-only STATUS current DESCRIPTION "The location information consists of PCI bus number, device number, and function. e.g. PCI bus 0, device 0, funciton 0" ::= {pciSlotEntry 13} psBaseAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(80)) ACCESS read-only STATUS mandatory DESCRIPTION "Base address mapping registers for memory and IO. Refer to the PCI specification for the format. A memory or IO address is encoded as hex. For example: A memory start address 0xF7E00000 will be encoded as (hex)00 00 00 00 F7 E0 00 00. According to the PCI specification, The IO address bit 0 will be 1. An IO address 0xE800 will be encoded as (hex)00 00 00 00 00 00 E8 01. " ::= {pciSlotEntry 14} psLength OBJECT-TYPE SYNTAX OCTET STRING (SIZE(80)) ACCESS read-only STATUS mandatory DESCRIPTION "The length of each PCI resource. It will be encoded as hex. For example: Length 0x20000 will be encoded as (hex) 00 00 00 00 00 02 00 00" ::= {pciSlotEntry 15} psIRQ OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "which interrupt pin the device uses." ::= {pciSlotEntry 16} psState OBJECT-TYPE SYNTAX INTEGER { enabled (1), disabled (2) } ACCESS read-only STATUS current DESCRIPTION "The PCI device enable status" ::= {pciSlotEntry 17} psModuleType OBJECT-TYPE SYNTAX INTEGER { com(1), can(2), amonet(3), motion(4), wireless(5) } ACCESS read-only STATUS current DESCRIPTION "The module function type" ::= {pciSlotEntry 18} psModulePorts OBJECT-TYPE SYNTAX Integer32 ACCESS read-only STATUS current DESCRIPTION "The port/ring/axis total number ports of the module" ::= {pciSlotEntry 19} END