-- Title: ALVARION Private MIB -- This Private MIB supports BreezeAccess_VL, BreezeACCESS_4900 and BreezeNET-B product lines. -- -- -- Version: 4.5.16 -- Date: Tuesday August 14 2007 -- Comments: ALVARION agents also support the following Public MIBs: -- This MIB supports BreezeACCESS VL products (AU and SU), -- BreezeACCESS 4900 (AU and SU) and -- BreezeNET-B products (BU and RB). -- Some MIB compilers require that the following lines -- for proper compilation --#include "rfc1155.smi" --#include "rfc1212.smi" -- mgmt OBJECT IDENTIFIER ::= { iso org(3) dod(6) internet(1) mgmt(2) } -- mib OBJECT IDENTIFIER ::= { mgmt 1 } -- directory OBJECT IDENTIFIER ::= { internet 1 } -- experimental OBJECT IDENTIFIER ::= { internet 3 } -- private OBJECT IDENTIFIER ::= { internet 4 } -- enterprises OBJECT IDENTIFIER ::= { private 1 } -- End of lines which might be needed to other MIB browsers -- for proper compilation ALVARION-DOT11-WLAN-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, NOTIFICATION-TYPE, enterprises, IpAddress,Counter32,OBJECT-TYPE FROM SNMPv2-SMI; alvarion OBJECT IDENTIFIER ::= { enterprises 12394 } products OBJECT IDENTIFIER ::= { alvarion 1 } breezeAccessVLMib MODULE-IDENTITY LAST-UPDATED "0708141146Z" ORGANIZATION "Alvarion Ltd." CONTACT-INFO "Alvarion Customer Service Postal: Alvarion Ltd. Barzel 21 Tel Aviv 69710 ISRAEL E-mail: CS_Coordinator@alvarion.com" DESCRIPTION "BreezeAccess VL, BreezeACCESS 4900 and BreezeNET-B" REVISION "0708141146Z" DESCRIPTION "Version 4.5" ::= { products 1 } MacAddress ::= OCTET STRING (SIZE(6)) DisplayString ::= OCTET STRING alvarionOID OBJECT IDENTIFIER ::= { alvarion 4 } brzAccessVLOID OBJECT IDENTIFIER ::= { alvarionOID 1 } brzAccessVLAU OBJECT IDENTIFIER ::= { brzAccessVLOID 1 } brzAccessVLSU OBJECT IDENTIFIER ::= { brzAccessVLOID 2 } brzAccessVLAU-BS OBJECT IDENTIFIER ::= { brzAccessVLOID 4 } brzAccessVLAU-SA OBJECT IDENTIFIER ::= { brzAccessVLOID 5 } brzAccessVLAUS-BS OBJECT IDENTIFIER ::= { brzAccessVLOID 6 } brzAccessVLAUS-SA OBJECT IDENTIFIER ::= { brzAccessVLOID 7 } brzAccessAU-EZ OBJECT IDENTIFIER ::= { brzAccessVLOID 8 } brzAccessVLSU-6-1D OBJECT IDENTIFIER ::= { brzAccessVLOID 11 } brzAccessVLSU-6-BD OBJECT IDENTIFIER ::= { brzAccessVLOID 12 } brzAccessVLSU-24-BD OBJECT IDENTIFIER ::= { brzAccessVLOID 13 } brzAccessVLSU-BD OBJECT IDENTIFIER ::= { brzAccessVLOID 14 } brzAccessVLSU-54-BD OBJECT IDENTIFIER ::= { brzAccessVLOID 15 } brzAccessVLSU-3-1D OBJECT IDENTIFIER ::= { brzAccessVLOID 16 } brzAccessVLSU-3-4D OBJECT IDENTIFIER ::= { brzAccessVLOID 17 } brzAccessVLSU-I OBJECT IDENTIFIER ::= { brzAccessVLOID 18 } brzNetB-BU-B14 OBJECT IDENTIFIER ::= { brzAccessVLOID 21 } brzNetB-BU-B28 OBJECT IDENTIFIER ::= { brzAccessVLOID 22 } brzNetB-BU-B100 OBJECT IDENTIFIER ::= { brzAccessVLOID 23 } brzNetB-RB-B14 OBJECT IDENTIFIER ::= { brzAccessVLOID 31 } brzNetB-RB-B28 OBJECT IDENTIFIER ::= { brzAccessVLOID 32 } brzNetB-RB-B100 OBJECT IDENTIFIER ::= { brzAccessVLOID 33 } brzAccess4900-AU-BS OBJECT IDENTIFIER ::= { brzAccessVLOID 41 } brzAccess4900-AU-SA OBJECT IDENTIFIER ::= { brzAccessVLOID 42 } brzAccess4900-SU-BD OBJECT IDENTIFIER ::= { brzAccessVLOID 51 } brzAccessVLProducts OBJECT IDENTIFIER ::= { brzAccessVLOID 3 } -- **************************************************************************************** -- **************************************************************************************** -- General System Info -- =================== brzaccVLSysInfo OBJECT IDENTIFIER ::= {breezeAccessVLMib 1} brzaccVLUnitHwVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Hardware platform version." ::= { brzaccVLSysInfo 1 } brzaccVLRunningSoftwareVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Running software version." ::= { brzaccVLSysInfo 2 } brzaccVLRunningFrom OBJECT-TYPE SYNTAX INTEGER { mainVersion(1) , shadowVersion(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The memory (main or shadow) from which the current version is running from." ::= { brzaccVLSysInfo 3 } brzaccVLMainVersionNumber OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Main software version number." ::= { brzaccVLSysInfo 4 } brzaccVLMainVersionFileName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Main software version file name." ::= { brzaccVLSysInfo 5 } brzaccVLShadowVersionNumber OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Shadow software version number." ::= { brzaccVLSysInfo 6 } brzaccVLShadowVersionFileName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Shadow software version file name." ::= { brzaccVLSysInfo 7 } brzaccVLUnitMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Unit hardware MAC address." ::= { brzaccVLSysInfo 8 } brzaccVLUnitType OBJECT-TYPE SYNTAX INTEGER {auBS (1), auSA(2) , su-6-1D(3),su-6-BD(4),su-24-BD(5), bu-B14(6),bu-B28(7),rb-B14(8),rb-B28(9),su-BD(10),su-54-BD (11), su-3-1D(12),su-3-4D(13),ausBS(14),ausSA(15), auBS4900(16),auSA4900(17),su4900(18), bu-B100(19), rb-B100(20), su-I(21), au-E(22) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. auBS (1) : AU-BS (modular access unit). auSA (2) : AU-SA (stand-alone access unit). su-6-1D (3) : SU-6-1D (subscriber unit supporting 6 Mbps) su-6-BD (4) : SU-6-BD (subscriber unit supporting 6 Mbps). su-24-BD (5) : SU-24-BD (subscriber unit supporting 24 Mbps). bu-B14 (6) : BU-B14 (BreezeNET Base Unit supporting 14 Mbps). bu-B28 (7) : BU-B28 (BreezeNET Base Unit supporting 28 Mbps). rb-B14 (8) : RB-B14 (BreezeNET Remote Bridge supporting 14 Mbps). rb-B28 (9) : RB-B28 (BreezeNET Remote Bridge supporting 28 Mbps). su-BD (10) : SU-BD (subscriber unit). su-54-BD(11) : SU-54-BD (subscriber unit supporting 54 Mbps). su-3-1D (12) : SU-3-1D (subscriber unit supporting 3 Mbps). su-3-4D (13) : SU-3-4D (subscriber unit supporting 3 Mbps). ausBS (14) : AUS-BS (modular access unit supporting maxim 8 or 25 (via licensing) subscribers and allowing association only with SU-3 or SU-6). ausSA (15) : AUS-SA (stand-alone access unit supporting maxim 8 or 25 (via licensing) subscribers and allowing association only with SU-3 or SU-6 ). auBS4900(16) : AU-BS-4900 (BreezeAccess 4900 modular access unit) auSA4900(17) : AU-SA-4900 (BreezeAccess 4900 stand alone access unit) suBD4900(18) : SU-BD-4900 (BreezeAccess 4900 subscriber unit) bu-B100 (19) : BU-B100 (BreezeNET Base Unit unlimited throughput) rb-B100 (20) : BU-B100 (BreezeNET Remote Bridge unlimited throughput) su-I (21) : SU-I au-E (22) : AU-E" ::= { brzaccVLSysInfo 9 } brzaccVLAssociatedAU OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. Associated AU/BU MAC address." ::= { brzaccVLSysInfo 10 } brzaccVLNumOfAssociationsSinceLastReset OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of associations since last reset, including duplicate associations (re-associations)." ::= { brzaccVLSysInfo 11 } brzaccVLCurrentNumOfAssociations OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BreezeNET-B products. The number of SUs currently associated with the AU. BreezeNET-B products return 65535." ::= { brzaccVLSysInfo 13 } brzaccVLUnitBootVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Boot version." ::= { brzaccVLSysInfo 14 } brzaccVLRadioBand OBJECT-TYPE SYNTAX INTEGER {band-5-8GHz (1), band-5-4GHz (2) , band-4-9GHz (3),band-5-2GHz (4),band-2-4GHz (5),band-5-3GHz (6),band-4-9GHzJapan (7)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The unit's radio band." ::= { brzaccVLSysInfo 15 } brzaccVLCurrentEthernetPortState OBJECT-TYPE SYNTAX INTEGER { halfDuplexAnd10Mbps (1), fullDuplexAnd10Mbps (2), halfDuplexAnd100Mbps (3), fullDuplexAnd100Mbps (4), linkDown (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The current Ethernet port state." ::= { brzaccVLSysInfo 16 } brzaccVLTimeSinceLastReset OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The elapsed time since last reset." ::= { brzaccVLSysInfo 17 } brzaccVLCountryDependentParameters OBJECT IDENTIFIER ::= {brzaccVLSysInfo 18} brzaccVLCountryCode OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The country code and country name or country group name that is supported by the unit." ::= { brzaccVLCountryDependentParameters 1 } brzaccVLCountryDependentParamsTable OBJECT-TYPE SYNTAX SEQUENCE OF BrzaccVLCountryDependentParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. A table of country dependent parameters." ::= {brzaccVLCountryDependentParameters 2} brzaccVLCountryDependentParameterEntry OBJECT-TYPE SYNTAX BrzaccVLCountryDependentParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. An entry in the Country Dependent Parameters table." INDEX { brzaccVLCountryDependentParameterTableIdx } ::= { brzaccVLCountryDependentParamsTable 1 } BrzaccVLCountryDependentParameterEntry ::= SEQUENCE { brzaccVLCountryDependentParameterTableIdx INTEGER, brzaccVLCountryDependentParameterFrequencies DisplayString, brzaccVLAllowedBandwidth INTEGER, brzaccVLRegulationMaxTxPowerAtAntennaPort INTEGER, brzaccVLRegulationMaxEIRP INTEGER, brzaccVLMinModulationLevel INTEGER, brzaccVLMaxModulationLevel INTEGER, brzaccVLBurstModeSupport INTEGER, brzaccVLMaximumBurstDuration INTEGER, brzaccVLDfsSupport INTEGER, brzaccVLMinimumHwRevision INTEGER } brzaccVLCountryDependentParameterTableIdx OBJECT-TYPE SYNTAX INTEGER (1..5) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The sub-band ID of the entry in the Country Dependent Parameters table. Serves also as index for the table entry." ::= { brzaccVLCountryDependentParameterEntry 1 } brzaccVLCountryDependentParameterFrequencies OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The frequencies included in the applicable sub-band entry." ::= { brzaccVLCountryDependentParameterEntry 2 } brzaccVLAllowedBandwidth OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The bandwidth when using the applicable the sub-band." ::= { brzaccVLCountryDependentParameterEntry 3 } brzaccVLRegulationMaxTxPowerAtAntennaPort OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The maximum allowed Tx power when using the applicable sub-band. A RegulationMaxTxPowerAtAntennaPort of 255, means no limit" ::= { brzaccVLCountryDependentParameterEntry 4 } brzaccVLRegulationMaxEIRP OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The maximum Tx EIRP when using the applicable sub-band. A Regulation Max EIRP of 0, means no limit." ::= { brzaccVLCountryDependentParameterEntry 5 } brzaccVLMinModulationLevel OBJECT-TYPE SYNTAX INTEGER { level1 (1), level2 (2), level3 (3), level4 (4), level5 (5), level6 (6), level7 (7), level8 (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The minimum supported modulation level." ::= { brzaccVLCountryDependentParameterEntry 6 } brzaccVLMaxModulationLevel OBJECT-TYPE SYNTAX INTEGER { level1 (1), level2 (2), level3 (3), level4 (4), level5 (5), level6 (6), level7 (7), level8 (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The maximum supported modulation level." ::= { brzaccVLCountryDependentParameterEntry 7 } brzaccVLBurstModeSupport OBJECT-TYPE SYNTAX INTEGER {supported(1), notSupported(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The supported Burst Mode Option." ::= { brzaccVLCountryDependentParameterEntry 8} brzaccVLMaximumBurstDuration OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Applicable only if Burst Mode Option is supported. The maximum supported burst duration." ::= { brzaccVLCountryDependentParameterEntry 9} brzaccVLDfsSupport OBJECT-TYPE SYNTAX INTEGER {supported(1), notSupported(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The supported Dfs Option." ::= { brzaccVLCountryDependentParameterEntry 10} brzaccVLMinimumHwRevision OBJECT-TYPE SYNTAX INTEGER {hwRevisionA (1), hwRevisionB (2), hwRevisionC (3), hwRevisionD (4), hwRevisionE (5), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The Minimum HW Revision needed to support the country code." ::= { brzaccVLCountryDependentParameterEntry 11} brzaccVLAuthenticationEncryptionSupport OBJECT-TYPE SYNTAX INTEGER {supported(1), notSupported(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The supported Authentication Encryption Option." ::= { brzaccVLCountryDependentParameters 3 } brzaccVLDataEncryptionSupport OBJECT-TYPE SYNTAX INTEGER {supported(1), notSupported(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The supported Data Encryption Option." ::= { brzaccVLCountryDependentParameters 4 } brzaccVLAESEncryptionSupport OBJECT-TYPE SYNTAX INTEGER {supported(1), notSupported(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The supported AES Encryption Option." ::= { brzaccVLCountryDependentParameters 5 } brzaccVLAntennaGainChange OBJECT-TYPE SYNTAX INTEGER {supported(1), notSupported(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Indicates whether the Antenna Gain parameter is changeable or fixed." ::= { brzaccVLSysInfo 19 } brzaccVLAteTestResults OBJECT-TYPE SYNTAX INTEGER { none(0), pass(1), fail(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Results of ATE Test " ::= { brzaccVLSysInfo 20 } brzaccVLSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE(0..35)) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Serial Number of the unit" ::= { brzaccVLSysInfo 21 } -- Unit Control -- ============ brzaccVLUnitControl OBJECT IDENTIFIER ::= {breezeAccessVLMib 2} brzaccVLResetUnit OBJECT-TYPE SYNTAX INTEGER { cancel (1), resetSystemNow (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Resets the unit and applies new parameter values." ::= { brzaccVLUnitControl 1 } brzaccVLSetDefaults OBJECT-TYPE SYNTAX INTEGER { noDefaultSettingRequested (0), completeFactory (1), partialFactory (2), completeOperator (3), partialOperator (4), cancelCurrentPendingRequest(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Sets unit configuration to Defaults values after the next reset. noDefaultSettingRequested : Read-Only Option, no Default setting was Issued. completeFactory : All parameters revert to Factory Defaults values. partialFactory : All parameters revert to Factory Defaults values, except the parameters required for maintaining wireless connectivity. completeOperator: All parameters revert to Operator Defaults values. partialOperator : All parameters revert to Operator Defaults values, except the parameters required for maintaining wireless connectivity. cancelCurrentPendingRequest : Default Setting request is cancelled." ::= { brzaccVLUnitControl 2 } brzaccVLUnitName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The unit name. A string of up to 32 printable ASCII characters." ::= { brzaccVLUnitControl 3 } brzaccVLFlashMemoryControl OBJECT-TYPE SYNTAX INTEGER { resetAndBootFromShadowVersion (1), useRunningVersionAfterReset (2),cancel(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. resetAndBootFromShadowVersion : Activates the backup version. useRunningVersionAfterReset : The currently active version will become the main version and will be activated after next reset." ::= { brzaccVLUnitControl 4 } brzaccVLTelnetLogoutTimer OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Time-out of management via Telnet program. Automatic exit if the program is inactive for the defined time. Range: 1 to 999 (minutes)." ::= { brzaccVLUnitControl 5 } brzaccVLSaveCurrentConfigurationAsOperatorDefaults OBJECT-TYPE SYNTAX INTEGER { saveAsDefaults (1),cancel(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Saves the current configuration as Operator Defaults. Cannot be executed after requesting set defaults and the unit was not reset." ::= { brzaccVLUnitControl 6 } brzaccVLExitTelnet OBJECT-TYPE SYNTAX INTEGER { cancelOperation (1), exit (2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Exit the management via Telnet program." ::= { brzaccVLUnitControl 7 } brzaccVLUnitPasswords OBJECT IDENTIFIER ::= {brzaccVLUnitControl 8} brzaccVLReadOnlyPassword OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The User (read only) password. This is also the Read Community String. Up to 8 printable ASCII characters." ::= { brzaccVLUnitPasswords 1 } brzaccVLInstallerPassword OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The Installer password. Up to 8 printable ASCII characters." ::= { brzaccVLUnitPasswords 2 } brzaccVLAdminPassword OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The Administrator password. Accessible only with SNMP Write Community String (administrator password). Up to 8 printable ASCII characters." ::= { brzaccVLUnitPasswords 3 } brzaccVLEthernetNegotiationMode OBJECT-TYPE SYNTAX INTEGER { force10MbpsAndHalfDuplex (1), force10MbpsAndFullDuplex (2), force100MbpsAndHalfDuplex (3), force100MbpsAndFullDuplex (4), autoNegotiationMode (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The speed/duplex mode of the Ethernet port." ::= { brzaccVLUnitControl 9 } brzaccVLFTPParameters OBJECT IDENTIFIER ::= {brzaccVLUnitControl 10} brzaccVLFTPServerParams OBJECT IDENTIFIER ::= {brzaccVLFTPParameters 1} brzaccVLFTPServerUserName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..18)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The user name to be used for access to the FTP server. Accessible only with SNMP Write Community String (administrator password)." ::= { brzaccVLFTPServerParams 1 } brzaccVLFTPServerPassword OBJECT-TYPE SYNTAX DisplayString (SIZE(0..18)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The password to be used for access to the FTP server. Accessible only with SNMP Write Community String (administrator password)." ::= { brzaccVLFTPServerParams 2 } brzaccVLFTPClientIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. For SW version higher than 4.0 this is read-only. The IP address of the FTP stack in the unit." ::= { brzaccVLFTPServerParams 3 } brzaccVLFTPServerIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The IP address of the FTP server." ::= { brzaccVLFTPServerParams 4 } brzaccVLFTPClientMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The Mask of the FTP stack in the unit." ::= { brzaccVLFTPServerParams 5 } brzaccVLFTPGatewayIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The FTP Gateway address" ::= { brzaccVLFTPServerParams 6 } brzaccVLFTPSwDownload OBJECT IDENTIFIER ::= {brzaccVLFTPParameters 2} brzaccVLFTPSwFileName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The name of the SW file to be downloaded." ::= { brzaccVLFTPSwDownload 1 } brzaccVLFTPSwSourceDir OBJECT-TYPE SYNTAX DisplayString (SIZE(0..80)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The source directory of the required file in the FTP server. Up to 80 printable ASCII characters. Use dot (.) To clear field" ::= { brzaccVLFTPSwDownload 2 } brzaccVLFTPDownloadSwFile OBJECT-TYPE SYNTAX INTEGER { downloadFile (1) , cancel (2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Execution of the SW download operation" ::= { brzaccVLFTPSwDownload 3 } brzaccVLConfigurationFileLoading OBJECT IDENTIFIER ::= {brzaccVLFTPParameters 3} brzaccVLConfigurationFileName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The name of the configuration file to be downloaded/uploaded." ::= { brzaccVLConfigurationFileLoading 1 } brzaccVLOperatorDefaultsFileName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The name of the Operator Defaults file to be downloaded/uploaded" ::= { brzaccVLConfigurationFileLoading 2 } brzaccVLFTPConfigurationFileSourceDir OBJECT-TYPE SYNTAX DisplayString (SIZE(0..80)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The source directory of the required file in the FTP server. Up to 80 printable ASCII characters. Use dot (.) To clear field" ::= { brzaccVLConfigurationFileLoading 3 } brzaccVLExecuteFTPConfigurationFileLoading OBJECT-TYPE SYNTAX INTEGER {executeFTPGetConfigurationFile (1), executeFTPPutConfigurationFile (2), executeFTPGetOperatorDefaults (3) , executeFTPPutOperatorDefaults (4), cancel (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Execution of the file download/upload operation." ::= { brzaccVLConfigurationFileLoading 4 } brzaccVLEventLogFileUploading OBJECT IDENTIFIER ::= {brzaccVLFTPParameters 4} brzaccVLEventLogFileName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The name of the Event Log file to be uploaded." ::= { brzaccVLEventLogFileUploading 1 } brzaccVLEventLogDestinationDir OBJECT-TYPE SYNTAX DisplayString (SIZE(0..80)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The destination directory of the event log file. Up to 80 printable ASCII characters. Use dot (.) To clear field." ::= { brzaccVLEventLogFileUploading 2 } brzaccVLUploadEventLogFile OBJECT-TYPE SYNTAX INTEGER { uploadFile (1) , cancel (2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Execution of the event log upload operation." ::= { brzaccVLEventLogFileUploading 3 } brzaccVLLoadingStatus OBJECT-TYPE SYNTAX INTEGER {inProcess (1), successful (2), failed (3)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The status of the last loading operation." ::= { brzaccVLUnitControl 11 } brzaccVLEventLogFileParams OBJECT IDENTIFIER ::= {brzaccVLUnitControl 12} brzaccVLEventLogPolicy OBJECT-TYPE SYNTAX INTEGER {message (1), warning (2), error (3),fatal(4), logNone(5)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The lowest level event to be registered in the event log." ::= { brzaccVLEventLogFileParams 1 } brzaccVLEraseEventLog OBJECT-TYPE SYNTAX INTEGER { eraseEventLog (1),cancel(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Erase the event log." ::= { brzaccVLEventLogFileParams 2 } brzaccVLSystemLocation OBJECT-TYPE SYNTAX DisplayString (SIZE(0..34)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The unit location." ::= { brzaccVLUnitControl 13 } brzaccVLFeatureUpgrade OBJECT IDENTIFIER ::= {brzaccVLUnitControl 14} brzaccVLFeatureUpgradeManually OBJECT-TYPE SYNTAX DisplayString (SIZE(32..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Upgrade unit to support new feature. Enter your license number (32 to 64 hex digits)." ::= { brzaccVLFeatureUpgrade 1 } brzaccVLChangeUnitType OBJECT-TYPE SYNTAX INTEGER { bu(1), rb(2), cancel(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable RB/BU only. Change the unit type between BU and RB." ::= { brzaccVLUnitControl 15 } brzaccLighteAPWorkingMode OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. Change unit running mode: 0 - VL mode 1 - Mixed cell mode" ::= { brzaccVLUnitControl 16 } -- Network Management Params -- ========================= brzaccVLNwMngParameters OBJECT IDENTIFIER ::= {breezeAccessVLMib 3} brzaccVLAccessToNwMng OBJECT-TYPE SYNTAX INTEGER { fromWirelessOnly (1), fromEthernetOnly (2), fromBothWirelessAndEthernet (3), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The port to be used for remote management." ::= { brzaccVLNwMngParameters 1 } brzaccVLNwMngFilter OBJECT-TYPE SYNTAX INTEGER { disable (1), activateOnEthernetPort (2), activateOnWirelessPort (3), activateOnBothWirelessAndEthernet (4), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Disables or enable on one of the ports, or on both ports, IP address based filtering of management messages (e.g. SNMP , Telnet , TFTP , DHCP)." ::= { brzaccVLNwMngParameters 2 } mngIpFilterTable OBJECT-TYPE SYNTAX SEQUENCE OF MngIpFilterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. A Management IP Filter Table of up to 3 IP addresses of devices that are authorized to access the unit for management purposes." ::= { brzaccVLNwMngParameters 3 } mngIpFilterEntry OBJECT-TYPE SYNTAX MngIpFilterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. A Management IP Filter Table entry." INDEX { brzaccVLNwMngIpTableIdx } ::= { mngIpFilterTable 1 } MngIpFilterEntry ::= SEQUENCE { brzaccVLNwMngIpAddress IpAddress, brzaccVLNwMngIpTableIdx INTEGER } brzaccVLNwMngIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. An IP address in the Management IP Filter Table." ::= { mngIpFilterEntry 1 } brzaccVLNwMngIpTableIdx OBJECT-TYPE SYNTAX INTEGER (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. A table index for an entry in the Management IP Filter Table." ::= { mngIpFilterEntry 2 } brzaccVLDeleteOneNwIpAddr OBJECT-TYPE SYNTAX INTEGER (0 | 1..10 | 255) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. 0 - cancel operation. 1..10 - Deletes a single selected entry from the Management IP Filter Table." ::= { brzaccVLNwMngParameters 4 } brzaccVLDeleteAllNwIpAddrs OBJECT-TYPE SYNTAX INTEGER { deleteAll (1), cancelOperation (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Deletes all entries from the Management IP Filter Table." ::= { brzaccVLNwMngParameters 5 } brzaccVLAccessToNwTrap OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Enables or disables sending of traps." ::= { brzaccVLNwMngParameters 6 } mngTrapTable OBJECT-TYPE SYNTAX SEQUENCE OF MngTrapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. A Management Trap Table of up to 10 IP addresses of stations to send traps to." ::= { brzaccVLNwMngParameters 7 } mngTrapEntry OBJECT-TYPE SYNTAX MngTrapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. A Management Trap Table entry." INDEX { brzaccVLNwTrapTableIdx } ::= { mngTrapTable 1 } MngTrapEntry ::= SEQUENCE { brzaccVLNwMngTrapCommunity DisplayString, brzaccVLNwMngTrapAddress IpAddress, brzaccVLNwTrapTableIdx INTEGER } brzaccVLNwMngTrapCommunity OBJECT-TYPE SYNTAX DisplayString (SIZE(0..14)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The trap community associated with the applicable entry in the Management Trap Table. Up to 14 printable case sensitive ASCII characters." ::= { mngTrapEntry 1 } brzaccVLNwMngTrapAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. An IP address in the Management Trap Table entry." ::= { mngTrapEntry 2 } brzaccVLNwTrapTableIdx OBJECT-TYPE SYNTAX INTEGER (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Tables Index for an entry in the Management Trap Table." ::= { mngTrapEntry 3 } brzaccVLDeleteOneTrapAddr OBJECT-TYPE SYNTAX INTEGER (0 | 1..10 | 255) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. 0 - cancel operation. 1..10 - Deletes a single selected entry from the Management Trap Table." ::= { brzaccVLNwMngParameters 8 } brzaccVLDeleteAllTrapAddrs OBJECT-TYPE SYNTAX INTEGER { deleteAll (1),cancelOperation (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Deletes all entries from the Management Trap Table." ::= { brzaccVLNwMngParameters 9 } brzaccVLMngIpRangesTable OBJECT-TYPE SYNTAX SEQUENCE OF BrzaccVLMngIpRangeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. Table of Management IP Address Ranges" ::= { brzaccVLNwMngParameters 10 } brzaccVLMngIpRangeEntry OBJECT-TYPE SYNTAX BrzaccVLMngIpRangeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. A Management IP Address Ranges Table entry" INDEX { brzaccVLMngIpRangeIdx } ::= { brzaccVLMngIpRangesTable 1 } BrzaccVLMngIpRangeEntry ::= SEQUENCE { brzaccVLMngIpRangeIdx INTEGER, brzaccVLMngIpRangeFlag INTEGER, brzaccVLMngIpRangeStart IpAddress, brzaccVLMngIpRangeEnd IpAddress, brzaccVLMngIpRangeMask IpAddress } brzaccVLMngIpRangeIdx OBJECT-TYPE SYNTAX INTEGER (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Index of an entry in the Management IP Address Ranges Table" ::= { brzaccVLMngIpRangeEntry 1 } brzaccVLMngIpRangeFlag OBJECT-TYPE SYNTAX INTEGER { rangeDefinedByStartEndAddr(1), rangeDefinedByStartAddrMask(2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Defines the method of defining the range: Using Start & End Address( rangeDefinedByStartEndAddr ), or using Start Address and Mask ( rangeDefinedByStartAddrSubNetMask )." ::= { brzaccVLMngIpRangeEntry 2 } brzaccVLMngIpRangeStart OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Start Address of the range" ::= { brzaccVLMngIpRangeEntry 3 } brzaccVLMngIpRangeEnd OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. End Address of the range. Used only if brzaccVLMngIpRangeFlag is rangeDefinedByStartEndAddr" ::= { brzaccVLMngIpRangeEntry 4 } brzaccVLMngIpRangeMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. End Address of the range. Used only if brzaccVLMngIpRangeFlag is rangeDefinedByStartAddrMask" ::= { brzaccVLMngIpRangeEntry 5 } brzaccVLDeleteOneNwIpRange OBJECT-TYPE SYNTAX INTEGER (0 | 1..10 | 255) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. 0 - cancel operation. 1..10 - Deletes a single selected entry from the Management IP Ranges Table." ::= { brzaccVLNwMngParameters 11 } brzaccVLDeleteAllNwIpRanges OBJECT-TYPE SYNTAX INTEGER { deleteAll (1), cancelOperation (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Deletes all entries from the Management IP Ranges Table." ::= { brzaccVLNwMngParameters 12 } brzaccVLApClientIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB unit only. The IP Address of the WIFI WIMAX unit" ::= { brzaccVLNwMngParameters 13 } -- IP Params: -- =========== brzaccVLIpParams OBJECT IDENTIFIER ::= {breezeAccessVLMib 4} brzaccVLUnitIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. IP address of the unit." ::= { brzaccVLIpParams 1 } brzaccVLSubNetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Subnet mask of the unit." ::= { brzaccVLIpParams 2 } brzaccVLDefaultGWAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Default gateway IP address of the unit." ::= { brzaccVLIpParams 3 } brzaccVLUseDhcp OBJECT-TYPE SYNTAX INTEGER{ disable (1), dhcpOnly (2), automatic (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. DHCP client mode of operation. disabled : Use regular (manual) methods to configure IP parameters. dHCP Only: Use DHCP server to configure IP parameters. automatic: Use DHCP server to configure IP parameters. If a DHCP server is not available, use manually configured values." ::= { brzaccVLIpParams 4 } brzaccVLAccessToDHCP OBJECT-TYPE SYNTAX INTEGER{ fromWirelessOnly (1), fromEthernetOnly (2), fromBothWirelessAndEthernet (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The port to be used for communicating with a DHCP server." ::= { brzaccVLIpParams 5 } brzaccVLRunTimeIPaddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The run-time IP address. If DHCP is used the Run Time IP Address is the address given to the unit by the server. Otherwise it is the manually configured address." ::= { brzaccVLIpParams 6 } brzaccVLRunTimeSubNetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The run-time Subnet Mask. If DHCP is used the Run Time Subnet Mask is the mask given to the unit by the server. Otherwise it is the manually configured mask." ::= { brzaccVLIpParams 7 } brzaccVLRunTimeDefaultIPGateway OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The run-time Gateway IP address. If DHCP is used the Run Time Gateway IP Address is the address given to the unit by the server. Otherwise it is the manually configured address." ::= { brzaccVLIpParams 8 } -- Bridge Params -- ============== brzaccVLBridgeParameters OBJECT IDENTIFIER ::= {breezeAccessVLMib 5} brzaccVLVLANSupport OBJECT IDENTIFIER ::= {brzaccVLBridgeParameters 1} brzaccVLVlanID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. VLAN ID for data frame tagging. Applicable to Access Link only. Range: 1 to 4094. 0 - not applicable." ::= { brzaccVLVLANSupport 1 } brzaccVLEthernetLinkType OBJECT-TYPE SYNTAX INTEGER { accessLink (1), trunkLink (2), hybridLink (3), serviceProviderLink (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. VLAN support mode (Link Type). The Access Link option is not available for AU/BU. Service Provider Link is not available for BU/RB." ::= { brzaccVLVLANSupport 2 } brzaccVLManagementVlanID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. VLAN ID for management frame tagging. Range: 1 to 4094, 65535 for No VLAN tagging." ::= { brzaccVLVLANSupport 3 } brzaccVLVLANForwarding OBJECT IDENTIFIER ::= {brzaccVLVLANSupport 4} brzaccVLVlanForwardingSupport OBJECT-TYPE SYNTAX INTEGER { disable (1) , enable (2), na(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Enables or disables the VLAN forwarding feature. (applicable in Trunk and Service Provider links only)." ::= { brzaccVLVLANForwarding 1 } brzaccVLVlanForwardingTable OBJECT-TYPE SYNTAX SEQUENCE OF BrzaccVLVlanForwardingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. A VLAN Forwarding Table of up to 20 VLAN IDs of devices to which data frames are forwarded when VLAN Forwarding is Enabled. (applicable in Trunk and Service Provider links only)." ::= { brzaccVLVLANForwarding 2 } brzaccVLVlanForwardingEntry OBJECT-TYPE SYNTAX BrzaccVLVlanForwardingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. A VLAN Forwarding Table entry. (applicable in Trunk and Service Provider links only)." INDEX { brzaccVLVlanForwardingTableIdx } ::= { brzaccVLVlanForwardingTable 1 } BrzaccVLVlanForwardingEntry ::= SEQUENCE { brzaccVLVlanForwardingTableIdx INTEGER, brzaccVLVlanIdForwarding INTEGER } brzaccVLVlanForwardingTableIdx OBJECT-TYPE SYNTAX INTEGER (1..20) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. A read only table index for a VLAN entry in the VLAN Forwarding Table." ::= { brzaccVLVlanForwardingEntry 1 } brzaccVLVlanIdForwarding OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The list of VLAN ID's in the VLAN ID Forwarding Table. To Remove a VLAN ID - SET the corresponding entry to 0. To Add a new VLAN ID SET an entry which is currently 0. Range : 0 to 4094" ::= { brzaccVLVlanForwardingEntry 2 } brzaccVLVlanRelaying OBJECT IDENTIFIER ::= {brzaccVLVLANSupport 5} brzaccVLVlanRelayingSupport OBJECT-TYPE SYNTAX INTEGER { disable (1) , enable (2), na(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BreezeNET-B products. Enables or disables VLAN Relaying (applicable in Trunk and Service Provider links only)." ::= { brzaccVLVlanRelaying 1 } brzaccVLVlanRelayingTable OBJECT-TYPE SYNTAX SEQUENCE OF BrzaccVLVlanRelayingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BreezeNET-B products. A VLAN Relaying Table of up to 20 VLAN IDs of devices to which data frames are relayed when VLAN Relaying is Enabled. (applicable in Trunk and Service Provider links only)." ::= { brzaccVLVlanRelaying 2 } brzaccVLVlanRelayingEntry OBJECT-TYPE SYNTAX BrzaccVLVlanRelayingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BreezeNET-B products. A VLAN Relaying Table entry. (applicable in Trunk and Service Provider links only)." INDEX { brzaccVLVlanRelayingTableIdx } ::= { brzaccVLVlanRelayingTable 1 } BrzaccVLVlanRelayingEntry ::= SEQUENCE { brzaccVLVlanRelayingTableIdx INTEGER, brzaccVLVlanIdRelaying INTEGER } brzaccVLVlanRelayingTableIdx OBJECT-TYPE SYNTAX INTEGER (1..20) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BreezeNET-B products. A table index for a VLAN entry in the VLAN Relaying Table." ::= { brzaccVLVlanRelayingEntry 1 } brzaccVLVlanIdRelaying OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BreezeNET-B products. The list of VLAN ID's in the VLAN ID Relaying Table. To Remove a VLAN ID - SET the corresponding entry to 0. To Add a new VLAN ID SET an entry which is currently 0. Range: 0 to 4094 , 0 - remove entry." ::= { brzaccVLVlanRelayingEntry 2 } brzaccVLVLANTrafficPriority OBJECT IDENTIFIER ::= {brzaccVLVLANSupport 6} brzaccVLVlanDataPriority OBJECT-TYPE SYNTAX INTEGER { na(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. Priority tagging for data frames. Applicable to Access Link only. Range: 0 to 7." ::= { brzaccVLVLANTrafficPriority 1 } brzaccVLVlanManagementPriority OBJECT-TYPE SYNTAX INTEGER { na(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Priority tagging for management frames. Applicable to Access Link and Trunk Link only. Range: 0 to 7." ::= { brzaccVLVLANTrafficPriority 2 } brzaccVLVlanPriorityThreshold OBJECT-TYPE SYNTAX INTEGER { na(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Not applicable to units with SW version 3.1 or higher. Priority threshold for tagged frames received from Ethernet port. Applicable to Hybrid Link and Trunk Link only. Valid values: 0-7." ::= { brzaccVLVLANTrafficPriority 3 } brzaccVLVLANQinQ OBJECT IDENTIFIER ::= {brzaccVLVLANSupport 7} brzaccVLQinQEthertype OBJECT-TYPE SYNTAX INTEGER (33025 .. 36864|37120|37376) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU and SU. Not applicable to BreezeNET-B units. The Ethernet type of the Service Provider Tag. The range is 0x8101(33025) - 0x9000(36864), 0x9100(37120), 0x9200(37376)." ::= { brzaccVLVLANQinQ 1 } brzaccVLQinQProviderVlanID OBJECT-TYPE SYNTAX INTEGER (1..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU only. VLAN ID of the Service Provider Tag." ::= { brzaccVLVLANQinQ 2 } brzaccVLBridgeAgingTime OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Bridge aging time for devices on both the Ethernet and wireless link sides. Range: 20 to 2000 seconds." ::= { brzaccVLBridgeParameters 2 } brzaccVLBroadcastRelaying OBJECT-TYPE SYNTAX INTEGER { disable (1), broadcastMulticastEnable (2), broadcastEnable (3), multicastEnable (4), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BreezeNET-B products. Enables/disables the relaying of broadcast messages to the wireless link." ::= { brzaccVLBridgeParameters 4 } brzaccVLUnicastRelaying OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BreezeNET-B products. Enables/disables the relaying of unicast messages to the wireless link." ::= { brzaccVLBridgeParameters 5 } brzaccVLEthBroadcastFiltering OBJECT-TYPE SYNTAX INTEGER { disable (1), onEthernetOnly (2), onWirelessOnly (3), onBothWirelessAndEthernet (4), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. Enables/disables the filtering of Ethernet (layer2) broadcasts. disable : No filtering. onEthernetOnly : Filters broadcasts received on the Ethernet port only. onWirelessOnly : Filters broadcasts received on the Wlan port only. onBothWirelessAndEth: Filters broadcasts received on both ports." ::= { brzaccVLBridgeParameters 6 } brzaccVLEthBroadcastingParameters OBJECT IDENTIFIER ::= {brzaccVLBridgeParameters 7} brzaccVLDHCPBroadcastOverrideFilter OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. Enables or disables the broadcasting of DHCP messages, overriding the general *brzaccVLEthBroadcastFiltering Ethernet broadcast filtering option." ::= { brzaccVLEthBroadcastingParameters 1 } brzaccVLPPPoEBroadcastOverrideFilter OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. Enables or disables the broadcasting of PPPoE messages, overriding the general *brzaccVLEthBroadcastFiltering Ethernet broadcast filtering option." ::= { brzaccVLEthBroadcastingParameters 2 } brzaccVLARPBroadcastOverrideFilter OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. Enables or disables the broadcasting of ARP messages, overriding the general *brzaccVLEthBroadcastFiltering Ethernet broadcast filtering option." ::= { brzaccVLEthBroadcastingParameters 3 } brzaccVLEthBroadcastMulticastLimiterOption OBJECT-TYPE SYNTAX INTEGER { disable (1), limitOnlyBroadcasts(2), limitMulticastsExceptBroadcasts(3), limitAllMulticasts(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Enable/disable the limiter for multicast and broadcast packets." ::= { brzaccVLEthBroadcastingParameters 4 } brzaccVLEthBroadcastMulticastLimiterThreshold OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The limit on the number of multicast and broadcast packets when the Ethernet Broadcast/Multicast Limiter Option is enabled. Range: 0 to 204800" ::= { brzaccVLEthBroadcastingParameters 5 } brzaccVLEthBroadcastMulticastLimiterSendTrapInterval OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The minimum time between two successive traps that are sent indicating the number of packets that were dropped by the Ethernet Broadcast/Multicast Limiter since the last trap was sent. Range: 1 to 60 minutes" ::= { brzaccVLEthBroadcastingParameters 6 } brzaccVLToSPriorityParameters OBJECT IDENTIFIER ::= {brzaccVLBridgeParameters 8} brzaccVLToSPrecedenceThreshold OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Not applicable to units with SW version 3.1 or higher. Priority threshold (based on the ToS) for frames received from the Ethernet port. Range: 0 to 7." ::= { brzaccVLToSPriorityParameters 1 } brzaccVLRoamingOption OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), na(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. Disable/enable the roaming feature. When enabled, the SU/RB will start scanning for an AU/BU after about one second of not receiving beacons or data from current AU/BU. Once it found a new AU/BU, it will also send through the wireless network a roaming SNAP on behalf of its clients informing other devices in the network of their new location. When disabled, it will wait for about seven seconds before starting scanning, and it will not send a roaming SNAP." ::= { brzaccVLBridgeParameters 9 } brzaccVLMacAddressDenyList OBJECT IDENTIFIER ::= {brzaccVLBridgeParameters 10} brzaccVLMacAddressDenyListTable OBJECT-TYPE SYNTAX SEQUENCE OF BrzaccVLMacAddressDenyListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BreezeNET-B units. A list of up to 100 MAC Addresses of SUs. If brzaccVLMacAddressDenyListAction is set to denyList, these are SUs that are not allowed to transfer data to the AU. If brzaccVLMacAddressDenyListAction is set to allowList, only these SUs are allowed to transfer data to the AU." ::= { brzaccVLMacAddressDenyList 1 } brzaccVLMacAddressDenyListEntry OBJECT-TYPE SYNTAX BrzaccVLMacAddressDenyListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BreezeNET-B units. An entry in the Mac Address Deny List Table." INDEX { brzaccVLMacAddressDenyListTableIdx } ::= { brzaccVLMacAddressDenyListTable 1 } BrzaccVLMacAddressDenyListEntry ::= SEQUENCE { brzaccVLMacAddressDenyListTableIdx INTEGER, brzaccVLMacAddressDenyListId MacAddress } brzaccVLMacAddressDenyListTableIdx OBJECT-TYPE SYNTAX INTEGER (1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BreezeNET-B units. A read only table index for a MAC Address entry in the Mac Address Deny List Table. Range: 1 to 100." ::= { brzaccVLMacAddressDenyListEntry 1 } brzaccVLMacAddressDenyListId OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BreezeNET-B units. The list of MAC Addresses in the Mac Address Deny List Table. To Remove a MAC Address - SET the corresponding entry to 0. To Add a new MAC Address - SET an entry which is currently 0." ::= { brzaccVLMacAddressDenyListEntry 2 } brzaccVLMacAddressDenyListAdd OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BreezeNET-B units. Add a MAC address to the MAC Address Deny List Table" ::= { brzaccVLMacAddressDenyList 2 } brzaccVLMacAddressDenyListRemove OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BreezeNET-B units. Delete a MAC address from the MAC Address Deny List Table" ::= { brzaccVLMacAddressDenyList 3 } brzaccVLNumberOfMacAddressesInDenyList OBJECT-TYPE SYNTAX INTEGER { na(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BreezeNET-B units. Number of MAC addresses in the MAC Address Deny List Table." ::= { brzaccVLMacAddressDenyList 4 } brzaccVLMacAddressDenyListAction OBJECT-TYPE SYNTAX INTEGER { denyList(1), allowedList(2), na(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. Define the action to be used by the Mac Address Deny List. allowedList(2) means that the list becomes Allow list." ::= { brzaccVLMacAddressDenyList 5 } brzAccVLPortsControl OBJECT IDENTIFIER ::= {brzaccVLBridgeParameters 11} brzaccVLEthernetPortControl OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2), na(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. Enable/disable the Ethernet port. When disabled, only data frames are blocked. Management frames are accepted." ::= { brzAccVLPortsControl 1 } -- Air Interface Params -- ===================== brzaccVLAirInterface OBJECT IDENTIFIER ::= {breezeAccessVLMib 6} brzaccVLESSIDParameters OBJECT IDENTIFIER ::= {brzaccVLAirInterface 1} brzaccVLESSID OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The Extended Service Set ID (ESSID) used to prevent the merging of collocated systems. The ESSID is accessible only with the write community string (administrator password). Up to 31 printable case sensitive ASCII characters." ::= { brzaccVLESSIDParameters 1 } brzaccVLOperatorESSIDOption OBJECT-TYPE SYNTAX INTEGER {disable (1) , enable (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. Enabling/disabling the use of the Operator ESSID." ::= { brzaccVLESSIDParameters 2 } brzaccVLOperatorESSID OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. A secondary ESSID to support easy installation of SUs as well as the use of the Best AU/BU feature. Accessible only with SNMP Write Community Up to 31 printable case sensitive ASCII characters." ::= { brzaccVLESSIDParameters 3} brzaccVLRunTimeESSID OBJECT-TYPE SYNTAX DisplayString (SIZE(31)) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. The ESSID of the associated AU/BU. Accessible only with SNMP Write Community. Up to 31 printable ASCII characters, case sensitive." ::= { brzaccVLESSIDParameters 4 } brzaccVLMaximumCellRadius OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. For AU/BU: read-write. In units with SW version 2.0 and up - applicable only when the Cell Distance Mode is set to Manual. The highest distance from the AU/BU of any SU/RB served by it. Affects the maximum time the units wait for a response message and the slot size by taking into account the round trip propagation delay. For SU/RB: read-only. The distance is learned from the AU/BU. Range: For units below version 2.0 the range is 0 - 50000 Meters. Otherwise - the range is 0 to 54 Kilometers. 0 means no compensation (minimum slot size, maximal delay timeout)." ::= { brzaccVLAirInterface 2 } brzaccVLAIFS OBJECT-TYPE SYNTAX INTEGER { oneSlot (1), twoSlots (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU and SU. Not applicable to BreezeNET-B products. Not applicable if Wireless Link Prioritization is enabled. Arbitration Inter-Frame Spacing (AIFS) value, in slots. This is the number of time slots that define the DIFS. (DIFS=SIFS+AIFS). A value of 1 should be used only in point-to-point applications to allow one unit to have advantage over the other unit." ::= { brzaccVLAirInterface 3 } brzaccVLWirelessTrapThreshold OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. A wireless link quality threshold, expressed in % of retransmissions, for sending the brzaccVLAUWirelessQualityTRAP. This trap indicate whether the quality has gone below or above the specified threshold. The Threshold Range: 1 to 100 (% retransmissions)." ::= { brzaccVLAirInterface 4 } brzaccVLTransmitPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF BrzaccVLTransmitPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. A table of transmit power parameters. " ::= { brzaccVLAirInterface 5} brzaccVLTransmitPowerEntry OBJECT-TYPE SYNTAX BrzaccVLTransmitPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. An entry in the Transmit Power Table." INDEX { brzaccVLTransmitPowerIdx } ::= { brzaccVLTransmitPowerTable 1 } BrzaccVLTransmitPowerEntry ::= SEQUENCE { brzaccVLTransmitPowerIdx INTEGER, brzaccVLApplicableModulationLevel INTEGER, brzaccVLMaximumTxPowerRange DisplayString, brzaccVLTxPower DisplayString, brzaccVLCurrentTxPower DisplayString } brzaccVLTransmitPowerIdx OBJECT-TYPE SYNTAX INTEGER (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. An index of an entry in the Transmit Power Table." ::= { brzaccVLTransmitPowerEntry 1 } brzaccVLApplicableModulationLevel OBJECT-TYPE SYNTAX INTEGER {level1to5 (1), level6 (2), level7 (3),level8 (4)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The applicable modulation level for an entry in the Transmit Power Table. Level 8 is not applicable to units with HW revision A." ::= { brzaccVLTransmitPowerEntry 2 } brzaccVLMaximumTxPowerRange OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The allowed range for the brzaccVLTxPower parameter at the applicable modulation level . Range: -10 to the maximum allowed power level at the applicable modulation level , in dBm." ::= { brzaccVLTransmitPowerEntry 3 } brzaccVLTxPower OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Read-only for units with SW version 4.0 and higher. In AU/BU: The transmit power in dBm defined for the applicable rate. In SU/RB: If ATPC is disabled, this is the transmit power in dBm defined for the applicable rate. If ATPC is enabled, it serves as the initial transmit power in dBm for the ATPC algorithm. In SU/RB: The range is -10 dBm to the power value defined by brzaccVLMaximumTxPower for the applicable modulation level. In AU/BU: The range is -10 dBm to the power value defined by brzaccVLMaximumTxPowerRange for the applicable modulation level." ::= { brzaccVLTransmitPowerEntry 4 } brzaccVLCurrentTxPower OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB. The actual transmit power in dBm for the applicable rate. Range: -17 to the maximum value defined by brzaccVLMaximumTxPowerRange for the applicable modulation level." ::= { brzaccVLTransmitPowerEntry 5 } brzaccVLMaximumTransmitPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF BrzaccVLMaximumTransmitPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to SU/RB only. A table of maximum transmit power parameters. " ::= { brzaccVLAirInterface 6} brzaccVLMaximumTransmitPowerEntry OBJECT-TYPE SYNTAX BrzaccVLMaximumTransmitPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to SU/RB only. An entry in the Maximum Transmit Power Table." INDEX { brzaccVLMaximumTransmitPowerIdx } ::= { brzaccVLMaximumTransmitPowerTable 1 } BrzaccVLMaximumTransmitPowerEntry ::= SEQUENCE { brzaccVLMaximumTransmitPowerIdx INTEGER, brzaccVLMaxTxApplicableModulationLevel INTEGER, brzaccVLDefinedMaximumTxPowerRange DisplayString, brzaccVLMaxTxPower DisplayString } brzaccVLMaximumTransmitPowerIdx OBJECT-TYPE SYNTAX INTEGER (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. An index of an entry in the Maximum Transmit Power Table." ::= { brzaccVLMaximumTransmitPowerEntry 1 } brzaccVLMaxTxApplicableModulationLevel OBJECT-TYPE SYNTAX INTEGER {level1to5 (1), level6 (2), level7 (3),level8 (4)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. The applicable modulation level for an entry in the Maximum Transmit Power Table. Level 8 is not applicable to units with HW revision A." ::= { brzaccVLMaximumTransmitPowerEntry 2 } brzaccVLDefinedMaximumTxPowerRange OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. The allowed range for the brzaccVLMaxTxPower parameter at the applicable modulation level . Range: -10 to the maximum allowed power level at the applicable modulation level , in dBm." ::= { brzaccVLMaximumTransmitPowerEntry 3 } brzaccVLMaxTxPower OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. Read-only for units with SW version 4.0 and higher. The maximum value that can be configured for the brzaccVLTxPower parameter. This is also the maximum power level that can be reached by the ATPC algorithm. The range is -10 dBm to the maximum value defined by brzaccVLDefinedMaximumTxPowerRange for the applicable modulation level." ::= { brzaccVLMaximumTransmitPowerEntry 4 } brzaccVLMaxNumOfAssociations OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BreezeNET-B products. Sets the upper limit for the number of SUs that can be associated with the AU. Range: For regular AUs (AU-BS, AU-SA) the range is from 0 to 512 if encryption is disabled the range id form 0 to 124 if encryption is enabled For AUS-BS and AUS-SA with SW version 4.0 and higher the range is between 0 to 8 or 25 (via licensing). For AUS-BS and AUS-SA with SW version below 4.0 the range is between 0 to 5. BreezeNET-B products return 65535." ::= { brzaccVLAirInterface 10 } brzaccVLBestAu OBJECT IDENTIFIER ::= {brzaccVLAirInterface 11} brzaccVLBestAuSupport OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. Disable/enable the Best AU/BU selection mechanism." ::= { brzaccVLBestAu 1 } brzaccVLBestAuNoOfScanningAttempts OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. The number of scanning attempts to collect information for the Best AU/BU decision. Range: 1 to 255." ::= { brzaccVLBestAu 2 } brzaccVLPreferredAuMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. The MAC address of the preferred AU/BU (overriding the Best AU/BU selection process). 000000000000 means no preferred AU/BU." ::= { brzaccVLBestAu 3 } brzaccVLNeighborAuTable OBJECT-TYPE SYNTAX SEQUENCE OF BrzaccVLNeighborAuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to SU/RB only. A table of data on neighboring AUs/BUs." ::= { brzaccVLBestAu 4} brzaccVLNeighborAuEntry OBJECT-TYPE SYNTAX BrzaccVLNeighborAuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to SU/RB only. An entry in the Neighbor AU/BU Table." INDEX { brzaccVLNeighborAuIdx } ::= { brzaccVLNeighborAuTable 1 } BrzaccVLNeighborAuEntry ::= SEQUENCE { brzaccVLNeighborAuIdx INTEGER, brzaccVLNeighborAuMacAdd MacAddress, brzaccVLNeighborAuESSID DisplayString, brzaccVLNeighborAuSNR INTEGER, brzaccVLNeighborAuAssocLoadStatus INTEGER, brzaccVLNeighborAuMark INTEGER, brzaccVLNeighborAuHwRevision INTEGER, brzaccVLNeighborAuCountryCode INTEGER, brzaccVLNeighborAuSwVer DisplayString, brzaccVLNeighborAuAtpcOption INTEGER, brzaccVLNeighborAuAdapModOption INTEGER, brzaccVLNeighborAuBurstModeOption INTEGER, brzaccVLNeighborAuDfsOption INTEGER, brzaccVLNeighborAuConcatenationOption INTEGER, brzaccVLNeighborAuLearnCountryCodeBySU INTEGER, brzaccVLNeighborAuSecurityMode INTEGER, brzaccVLNeighborAuAuthOption INTEGER, brzaccVLNeighborAuDataEncyptOption INTEGER, brzaccVLNeighborAuPerSuDistanceLearning INTEGER } brzaccVLNeighborAuIdx OBJECT-TYPE SYNTAX INTEGER (1..20) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. An index of an entry in the Neighbor AU/BU Table." ::= { brzaccVLNeighborAuEntry 1 } brzaccVLNeighborAuMacAdd OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. A MAC address of an AU/BU in the Neighbor AU/BU Table." ::= { brzaccVLNeighborAuEntry 2 } brzaccVLNeighborAuESSID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. The ESSID of an AU/BU in the Neighbor AU/BU Table. Accessible only with SNMP Write Community." ::= { brzaccVLNeighborAuEntry 3 } brzaccVLNeighborAuSNR OBJECT-TYPE SYNTAX INTEGER { na (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. The received signal quality (SNR) in dB of an AU/BU in the Neighbor AU/BU Table." ::= { brzaccVLNeighborAuEntry 4 } brzaccVLNeighborAuAssocLoadStatus OBJECT-TYPE SYNTAX INTEGER { full (1),notFull (2), na (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. Neighbor AU/BU association load status in the Neighbor AU/BU Table." ::= { brzaccVLNeighborAuEntry 5 } brzaccVLNeighborAuMark OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. Neighbor AU/BU mark in the Neighbor AU/BU Table." ::= { brzaccVLNeighborAuEntry 6 } brzaccVLNeighborAuHwRevision OBJECT-TYPE SYNTAX INTEGER {hwRevisionA (1), hwRevisionB (2), hwRevisionC (3), hwRevisionD (4), hwRevisionE (5),na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. Neighbor AU/BU HW revision in the Neighbor AU/BU Table." ::= { brzaccVLNeighborAuEntry 7 } brzaccVLNeighborAuCountryCode OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. Neighbor AU/BU supported country code in the Neighbor AU/BU Table." ::= { brzaccVLNeighborAuEntry 8 } brzaccVLNeighborAuSwVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. Neighbor AU/BU SW version in the Neighbor AU/BU Table." ::= { brzaccVLNeighborAuEntry 9 } brzaccVLNeighborAuAtpcOption OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. Neighbor AU/BU ATPC option configuration in the Neighbor AU/BU Table." ::= { brzaccVLNeighborAuEntry 10 } brzaccVLNeighborAuAdapModOption OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. Neighbor AU/BU adaptive modulation option configuration in the Neighbor AU/BU Table." ::= { brzaccVLNeighborAuEntry 11 } brzaccVLNeighborAuBurstModeOption OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. Neighbor AU/BU burst mode option configuration in the Neighbor AU/BU Table." ::= { brzaccVLNeighborAuEntry 12 } brzaccVLNeighborAuDfsOption OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), na(255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. Neighbor AU/BU DFS option configuration in the Neighbor AU/BU Table." ::= { brzaccVLNeighborAuEntry 14 } brzaccVLNeighborAuConcatenationOption OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. Neighbor AU/BU concatenation option configuration in the Neighbor AU/BU Table." ::= { brzaccVLNeighborAuEntry 15 } brzaccVLNeighborAuLearnCountryCodeBySU OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU only. Starting with 4.0 is not applicable for BA4900 and BreezeNET B products. Neighbor AU Learn Country Code by SU configuration in the Neighbor AU Table." ::= { brzaccVLNeighborAuEntry 17 } brzaccVLNeighborAuSecurityMode OBJECT-TYPE SYNTAX INTEGER {wep(1), aesOCB(2), fips197(3), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. Neighbor AU/BU security mode configuration in the Neighbor AU/BU Table." ::= { brzaccVLNeighborAuEntry 18 } brzaccVLNeighborAuAuthOption OBJECT-TYPE SYNTAX INTEGER {openSystem (1), sharedKey (2), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. Neighbor AU/BU authentication option configuration in the Neighbor AU/BU Table." ::= { brzaccVLNeighborAuEntry 19 } brzaccVLNeighborAuDataEncyptOption OBJECT-TYPE SYNTAX INTEGER {disable (1), enable (2), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. Neighbor AU/BU data encryption option configuration in the Neighbor AU/BU Table." ::= { brzaccVLNeighborAuEntry 20 } brzaccVLNeighborAuPerSuDistanceLearning OBJECT-TYPE SYNTAX INTEGER {disable (1), enable (2), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU only. Neighbor AU per SU distance learning option configuration in the Neighbor AU Table." ::= { brzaccVLNeighborAuEntry 21 } brzaccVLFrequencyDefinition OBJECT IDENTIFIER ::= {brzaccVLAirInterface 12} brzaccVLSubBandLowerFrequency OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Applicable to SU only. Not applicable to units with SW version 2.0 or higher. The lowest frequency in the subset to be used for scanning. For 5.8GHz products the range is 5740 to 5830 MHz using 10MHz resolution. For 4.9GHz products the range is 4920 to 5080 MHz using 10MHz resolution. For HW Revision C and above this leaf is not relevant - shall return 0." ::= { brzaccVLFrequencyDefinition 1 } brzaccVLSubBandUpperFrequency OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Applicable to SU only. Not applicable to units with SW version 2.0 or higher. The highest frequency in the subset to be used for scanning. For 5.8GHz products the range is 5740 to 5830 MHz using 10MHz resolution. For 4.9GHz products the range is 4920 to 5080 MHz using 10MHz resolution. For HW Revision C and above this leaf is not relevant - shall return 0." ::= { brzaccVLFrequencyDefinition 2 } brzaccVLScanningStep OBJECT-TYPE SYNTAX INTEGER { mhz-5(1), mhz-10(2) , mhz-20(3), na(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units - For flexible Sub-Bands only. For units with version 2.0 and above this is a read-only parameter. The scanning step to be used for generating the frequency subset." ::= { brzaccVLFrequencyDefinition 3 } brzaccVLFrequencySubsetTable OBJECT-TYPE SYNTAX SEQUENCE OF BrzaccVLFrequencySubsetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to SU/RB and to AU/BU. Not applicable to SU/RB with SW version 4.0 and higher. The Frequency Subset Table that includes all frequencies from the selected Sub-band." ::= { brzaccVLFrequencyDefinition 4 } brzaccVLFrequencySubsetEntry OBJECT-TYPE SYNTAX BrzaccVLFrequencySubsetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to SU/RB and to AU/BU. Not applicable to SU/RB with SW version 4.0 and higher. An entry in the Frequency Subset Table. " INDEX { brzaccVLFrequencySubsetTableIdx } ::= { brzaccVLFrequencySubsetTable 1 } BrzaccVLFrequencySubsetEntry ::= SEQUENCE { brzaccVLFrequencySubsetTableIdx INTEGER, brzaccVLFrequencySubsetFrequency INTEGER, brzaccVLFrequencySubsetActive INTEGER, brzaccVLFrequencySubsetFrequencyNew DisplayString } brzaccVLFrequencySubsetTableIdx OBJECT-TYPE SYNTAX INTEGER (1..40) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB and to AU/BU. Not applicable to SU/RB with SW version 4.0 and higher. An index of an entry in the Frequency subset Table." ::= { brzaccVLFrequencySubsetEntry 1 } brzaccVLFrequencySubsetFrequency OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB and to AU/BU. Not applicable to SU/RB with SW version 4.0 and higher. Applicable to all units with HW revision B and lower (for units with HW revision C and higher replaced by brzaccVLFrequencySubsetFrequencyNew to support a resolution of 0.5 MHz). The frequency in MHz of an entry in the Frequency Subset table." ::= { brzaccVLFrequencySubsetEntry 2 } brzaccVLFrequencySubsetActive OBJECT-TYPE SYNTAX INTEGER {active (1) , notActive (2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB and to AU/BU. Not applicable to SU/RB with SW version 4.0 and higher. The status of an entry in the Frequency subset Table. The frequency of an active entry will be included in the final list of frequencies to be used for scanning." ::= { brzaccVLFrequencySubsetEntry 3 } brzaccVLFrequencySubsetFrequencyNew OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Not applicable to SU/RB with SW version 4.0 and higher. The frequency in MHz of an entry in the Frequency Subset table. (Replaces brzaccVLFrequencySubsetFrequency to support a resolution of 0.5 MHz for units with HW revision C and higher)." ::= { brzaccVLFrequencySubsetEntry 4 } brzaccVLSetSelectedFreqSubset OBJECT-TYPE SYNTAX INTEGER {setSelectedFreqsSubset(1) ,cancel (2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB and to AU/BU. Not applicable to SU/RB with SW version 4.0 and higher. Apply the selected subset. After the next reset the new subset will be used." ::= { brzaccVLFrequencyDefinition 5 } brzaccVLCurrentFrequencySubsetTable OBJECT-TYPE SYNTAX SEQUENCE OF BrzaccVLCurrentFrequencySubsetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to SU/RB and to AU/BU. Not applicable to SU/RB with SW version 4.0 and higher. The Current Frequency Subset table. In SU/RB it includes all frequencies that are currently used for scanning. In AU/BU it includes all frequencies that can be used by the DFS mechanism (if applicable)" ::= { brzaccVLFrequencyDefinition 6 } brzaccVLCurrentFrequencySubsetEntry OBJECT-TYPE SYNTAX BrzaccVLCurrentFrequencySubsetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to SU/RB and to AU/BU. An entry in the Current Frequency Subset Table. " INDEX { brzaccVLCurrentFrequencySubsetTableIdx } ::= { brzaccVLCurrentFrequencySubsetTable 1 } BrzaccVLCurrentFrequencySubsetEntry ::= SEQUENCE { brzaccVLCurrentFrequencySubsetTableIdx INTEGER, brzaccVLCurrentFrequencySubsetFrequency INTEGER, brzaccVLCurrentFrequencySubsetFrequencyNew DisplayString } brzaccVLCurrentFrequencySubsetTableIdx OBJECT-TYPE SYNTAX INTEGER (1..40) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB and to AU/BU. An index of an entry in the Current Frequency subset Table. Not applicable to SU/RB with SW version 4.0 and higher." ::= { brzaccVLCurrentFrequencySubsetEntry 1 } brzaccVLCurrentFrequencySubsetFrequency OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Not applicable to SU/RB with SW version 4.0 and higher. Applicable to all units with HW revision B and lower (for units with HW revision C and higher replaced by brzaccVLCurrentFrequencySubsetFrequencyNew to support a resolution of 0.5 MHz). The frequency in MHz of an entry in the Current Frequency Subset table." ::= { brzaccVLCurrentFrequencySubsetEntry 2 } brzaccVLCurrentFrequencySubsetFrequencyNew OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Not applicable to SU/RB with SW version 4.0 and higher. The frequency in MHz of an entry in the Current Frequency Subset table. (Replaces brzaccVLCurrentFrequencySubsetFrequency to support a resolution of 0.5 MHz for units with HW revision C and higher)." ::= { brzaccVLCurrentFrequencySubsetEntry 3 } brzaccVLCurrentAUOperatingFrequency OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU with HW revision B and lower (for units with HW revision C and higher replaced by brzaccVLCurrentUOperatingFrequencyNew to support a resolution of 0.5 MHz). The operating frequency in MHz. For 5.8GHz products with SW version below 2.0 the range is 5740 to 5830 MHz using 10MHz resolution. For units with SW version 2.0 and up the range is as defined in the selected Sub Band." ::= { brzaccVLFrequencyDefinition 7 } brzaccVLCurrentAUOperatingFrequencyNew OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU. The operating frequency in MHz. (Replaces brzaccVLCurrentAUOperatingFrequency to support a resolution of 0.5 MHz for units with HW revision C and higher). For 5.8GHz products with SW version below 2.0 the range is 5740 to 5830 MHz using 10MHz resolution. For units with SW version 2.0 and up the range is as defined in the selected Sub Band." ::= { brzaccVLFrequencyDefinition 13 } brzaccVLAUDefinedFrequency OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU with HW revision B and lower (for units with HW revision C and higher replaced by brzaccVLAUDefinedFrequencyNew to support a resolution of 0.5 MHz). For 5.8GHz products with SW version below 2.0 this is the frequency in MHz of the AU/BU after the next reset. For units with SW version 2.0 and up this is the frequency in MHz to use when the DFS Option is disabled. For 5.8GHz products with SW version below 2.0 the range is 5740 to 5830 MHz using 10MHz resolution. For units with SW version 2.0 and up the range is as defined in the selected Sub Band." ::= { brzaccVLFrequencyDefinition 8 } brzaccVLAUDefinedFrequencyNew OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU. For 5.8GHz products with SW version below 2.0 this is the frequency in MHz of the AU/BU after the next reset. For units with SW version 2.0 and up this is the frequency in MHz to use when the DFS Option is disabled. (Replaces brzaccVLAUDefinedFrequency to support a resolution of 0.5 MHz for units with HW revision C and higher). For 5.8GHz products with SW version below 2.0 the range is 5740 to 5830 MHz using 10MHz resolution. For units with SW version 2.0 and up the range is as defined in the selected Sub Band." ::= { brzaccVLFrequencyDefinition 14 } brzaccVLCurrentSUOperatingFrequency OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. The frequency used currently by the unit. For 5.8GHz products with SW version below 2.0 the range is 5740 to 5830 MHz using 10MHz resolution. For units with SW version 2.0 and up the range is as defined in the selected Sub Band." ::= { brzaccVLFrequencyDefinition 9 } brzaccVLSubBandSelect OBJECT IDENTIFIER ::= {brzaccVLFrequencyDefinition 10} brzaccVLSelectSubBandIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units with SW version below 4.0 For units with SW version 4.0 and up it is applicable only for AU/BU. For SU/RB it defines only the sub-band for the Spectrum Analyzer. The ID of the sub-band used by the unit." ::= { brzaccVLSubBandSelect 1 } brzaccVLDFSParameters OBJECT IDENTIFIER ::= {brzaccVLFrequencyDefinition 11} brzaccVLDFSOption OBJECT-TYPE SYNTAX INTEGER { disable (1) , enable (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. Enabling/disabling the DFS Algorithm. Not applicable if DFS Option is not supported by the current Sub Band." ::= { brzaccVLDFSParameters 1 } brzaccVLDFSChannelCheckTime OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. Defines the time the unit checks the channel for presence of radar signals and does not transmit after power up or association or after moving to a new channel due to detecting radar in the used channel. Range: 1 to 3600 (seconds)." ::= { brzaccVLDFSParameters 3 } brzaccVLDFSChannelAvoidancePeriod OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. Defines the time after detecting radar signals in a channel of avoiding using the channel or adjacent channels in accordance with the bandwidth. Range: 1 to 60 (minutes)." ::= { brzaccVLDFSParameters 4 } brzaccVLDFSSuWaitingOption OBJECT-TYPE SYNTAX INTEGER { disable (1) , enable (2), na(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. Defines whether the associated SUs should wait for this AU/BU after it stopped transmitting due to radar detection, before they starts scanning for other AUs/BUs." ::= { brzaccVLDFSParameters 5 } brzaccVLDFSClearRadarDetectedChannelsAfterReset OBJECT-TYPE SYNTAX INTEGER { cancel (1), clearRadarChannels (2), na(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. Clear Radar Detected and Adjacent to Radar channels after unit reset. Returns the unit to operate in default frequency." ::= { brzaccVLDFSParameters 6 } brzaccVLDFSRadarDetectionChannelsTable OBJECT-TYPE SYNTAX SEQUENCE OF BrzaccVLDFSRadarDetectionChannelsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to AU/BU only. Applicable only when DFS option is on. Displays the current channels defined in the sub-band and their radar detection status." ::= { brzaccVLDFSParameters 7 } brzaccVLDFSRadarDetectionChannelsEntry OBJECT-TYPE SYNTAX BrzaccVLDFSRadarDetectionChannelsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to AU/BU only. An entry in the brzaccVLDFSRadarDetectionChannelsTable." INDEX { brzaccVLDFSChannelIdx } ::= { brzaccVLDFSRadarDetectionChannelsTable 1 } BrzaccVLDFSRadarDetectionChannelsEntry ::= SEQUENCE { brzaccVLDFSChannelIdx INTEGER, brzaccVLDFSChannelFrequency INTEGER, brzaccVLDFSChannelRadarStatus INTEGER, brzaccVLDFSChannelFrequencyNew DisplayString } brzaccVLDFSChannelIdx OBJECT-TYPE SYNTAX INTEGER (1..40) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Read-only. The index of the entry in the brzaccVLDFSRadarDetectionChannelsTable." ::= { brzaccVLDFSRadarDetectionChannelsEntry 1 } brzaccVLDFSChannelFrequency OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU with HW revision B and lower (for units with HW revision C and higher replaced by brzaccVLDFSChannelFrequency New to support a resolution of 0.5 MHz). The frequency in MHz of a channel in the DFS Radar Detection Channels Table." ::= { brzaccVLDFSRadarDetectionChannelsEntry 2 } brzaccVLDFSChannelRadarStatus OBJECT-TYPE SYNTAX INTEGER { radarFree (1), adjacentToRadar (2), radarDetected (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The radar detection status of a channel in brzaccVLDFSRadarDetectionChannelTable." ::= { brzaccVLDFSRadarDetectionChannelsEntry 3 } brzaccVLDFSChannelFrequencyNew OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU. The frequency of a channel in the DFS Radar Detection Channels Table. (Replaces brzaccVLDFSChannelFrequency to support a resolution of 0.5 MHz for units with HW revision C and higher)." ::= { brzaccVLDFSRadarDetectionChannelsEntry 4 } brzaccVLDFSMinimumPulsesToDetect OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. Defines the minimum number of pulses to detect a radar. Range: 1 - 100." ::= { brzaccVLDFSParameters 8 } brzaccVLDFSChannelReuseParameters OBJECT IDENTIFIER ::= {brzaccVLDFSParameters 9} brzaccVLDFSChannelReuseOption OBJECT-TYPE SYNTAX INTEGER { disable (1) , enable (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. Enabling/disabling the DFS Channel Reuse Algorithm. Not applicable if DFS Option is not supported by the current Sub Band." ::= { brzaccVLDFSChannelReuseParameters 1 } brzaccVLDFSRadarActivityAssessmentPeriod OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. Range: 1 to 12 (Houres)." ::= { brzaccVLDFSChannelReuseParameters 2 } brzaccVLDFSMaximumNumberOfDetectionsInAssessmentPeriod OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. Range: 1 to 10 (Times)." ::= { brzaccVLDFSChannelReuseParameters 3 } brzaccVLCountryCodeLearningBySU OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2), na(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. Starting with 4.0 it is nor applicable for BA4900 and BreezeNET B. Defines whether the SUs learn the country code of the AU." ::= { brzaccVLFrequencyDefinition 12 } -- AUTOMATIC SUB BAND SELECT BEGIN brzaccVLAutoSubBandSelect OBJECT IDENTIFIER ::= { brzaccVLFrequencyDefinition 15 } brzaccVLAutoSubBandSelectedFreqSubset OBJECT-TYPE SYNTAX INTEGER { setAllSelectedFreqsSubset(1), cancel (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB with SW version 4.0 and higher. Apply the selected subset. After the next reset the new subset will be used for scanning." ::= { brzaccVLAutoSubBandSelect 1 } brzaccVLAutoSubBandFrequencySubsetTable OBJECT-TYPE SYNTAX SEQUENCE OF BrzaccVLAutoSubBandFrequencySubsetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to SU/RB with SW version 4.0 and higher. The Frequency Subset Table that includes all available sub-bands and all the frequencies in these sub-bands." ::= { brzaccVLAutoSubBandSelect 2 } brzaccVLAutoSubBandFrequencySubsetEntry OBJECT-TYPE SYNTAX BrzaccVLAutoSubBandFrequencySubsetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to SU/RB with SW version 4.0 and higher. An entry in the Frequency Subset Table. " INDEX { brzaccVLAutoSubBandFrequencySubsetBandIdx, brzaccVLAutoSubBandFrequencySubsetFrequencyIdx } ::= { brzaccVLAutoSubBandFrequencySubsetTable 1 } BrzaccVLAutoSubBandFrequencySubsetEntry ::= SEQUENCE { brzaccVLAutoSubBandFrequencySubsetBandIdx INTEGER, brzaccVLAutoSubBandFrequencySubsetFrequencyIdx INTEGER, brzaccVLAutoSubBandFrequencySubsetActive INTEGER, brzaccVLAutoSubBandFrequencySubsetFrequency DisplayString } brzaccVLAutoSubBandFrequencySubsetBandIdx OBJECT-TYPE SYNTAX INTEGER (1..5) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB with SW version 4.0 and higher. The index of the applicable Sub Band. This is the Sub Band ID of the relevant entry in the Country Dependent Parameters table. Serves also as an index of the entry in the Frequency subset Table." ::= { brzaccVLAutoSubBandFrequencySubsetEntry 1 } brzaccVLAutoSubBandFrequencySubsetFrequencyIdx OBJECT-TYPE SYNTAX INTEGER (1..40) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB with SW version 4.0 and higher. The index of the applicable frequency in the applicable Sub Band. Serves also as an index of the entry in the Frequency subset Table." ::= { brzaccVLAutoSubBandFrequencySubsetEntry 2 } brzaccVLAutoSubBandFrequencySubsetActive OBJECT-TYPE SYNTAX INTEGER {active (1) , notActive (2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB with SW version 4.0 and higher. The status of an entry in the Auto Sub Band Frequency subset Table. The frequency of an active entry will be included in the final list of frequencies to be used for scanning." ::= { brzaccVLAutoSubBandFrequencySubsetEntry 3 } brzaccVLAutoSubBandFrequencySubsetFrequency OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB with SW version 4.0 and higher. The frequency in MHz of the entry in the Auto Sub Band Frequency Subset table." ::= { brzaccVLAutoSubBandFrequencySubsetEntry 4 } -- AUTOMATIC SUB BAND SELECT END brzaccVLATPC OBJECT IDENTIFIER ::= {brzaccVLAirInterface 13} brzaccVLAtpcOption OBJECT-TYPE SYNTAX INTEGER { disable (1) , enable (2) , na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable all units. Enabling/disabling the ATPC Algorithm." ::= { brzaccVLATPC 1 } brzaccVLDeltaFromMinSNRLevel OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable AU/BU only. The Minimum SNR Level plus the value of this parameter define the maximum desired level of the average SNR at the AU/BU. If the ATPC Option is enabled, than if the received SNR is above the maximum desired level, the AU/BU will transmit Power-Down messages to the applicable SU/RB. Range: 4 to 20 (dB)." ::= { brzaccVLATPC 2 } brzaccVLMinimumSNRLevel OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable AU/BU only. Defines the minimum desired level of the average SNR at the AU/BU. Below this level, if *AtpcOption is enabled, the AU/BU will transmit ATPC Power-Up messages to the applicable SU/RB. The *MinimumSNRLevel cannot be higher than *MaximumSNRLevel. Range: 4 to 60 (dB)." ::= { brzaccVLATPC 3 } brzaccVLMinimumIntervalBetweenATPCMessages OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable AU/BU only. The minimum interval between two consecutive AU/BU to SU/RB messages. Range: 1 to 3600 (Sec)." ::= { brzaccVLATPC 4 } brzaccVLPowerLevelSteps OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable AU/BU only. The step in dB that the SU/RB will use when receiving an ATPC Power-Up/Power-Down message. Range: 1 to 20 (dB)." ::= { brzaccVLATPC 6 } brzaccVLCellDistanceParameters OBJECT IDENTIFIER ::= {brzaccVLAirInterface 15} brzaccVLCellDistanceMode OBJECT-TYPE SYNTAX INTEGER { automatic (1) , manual (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable AU/BU only. The selected mode of deciding on Cell Distance." ::= { brzaccVLCellDistanceParameters 1 } brzaccVLFairnessFactor OBJECT-TYPE SYNTAX INTEGER { na (255)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable AU/BU only. Not applicable to BreezeNET-B products for SW version below 4.0. The percentage of the maximum distance that is taken into account in the time slot calculation. Range: 0 to 100 (Percent). A value of 0 means the minimal slot size (9 microseconds). BreezeNET-B products with SW version below 4.0 return na." ::= { brzaccVLCellDistanceParameters 2 } brzaccVLMeasuredCellDistance OBJECT-TYPE SYNTAX INTEGER {below-2-Km(1)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable AU/BU only. The Maximum Cell Distance as calculated by the AU/BU. Range: 0 to 54 (Kilometers)." ::= { brzaccVLCellDistanceParameters 3 } brzaccVLUnitWithMaxDistance OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable AU only. Not applicable to BreezeNET-B units. The MAC address of the unit with the maximum distance from the AU." ::= { brzaccVLCellDistanceParameters 4 } brzaccVLPerSuDistanceLearning OBJECT-TYPE SYNTAX INTEGER { disable (1) , enable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Aplicable to AU only. Applicable only if Cell Distance Mode is set to Automatic. When disabled, all SUs in the cell will use for the ACK Timeout the computed distance of the farthest SU. When enabled, each SU will use its own computed distance" ::= { brzaccVLCellDistanceParameters 5 } brzaccVLScanningMode OBJECT-TYPE SYNTAX INTEGER { passive (1), active (2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. The scanning mode. In cells where the DFS Option is enabled Scanning Mode is forced to Passive." ::= { brzaccVLAirInterface 16 } brzaccVLAntennaGain OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Read-write in units where brzaccVLAntennaGainChange is supported. Read-only in units where brzaccVLAntennaGainChange is not supported. The net gain (including cable attenuation for detached antennas) of the antenna. Range: 0 - to Maximum EIRP defined by country code + 10 (dBi). A value of -2 (this value is configurable only in factory) means don't care. A value of -1 (this value is configurable only in factory) means that the unit will not transmit until the actual value is configured." ::= { brzaccVLAirInterface 17 } brzaccVLSpectrumAnalysisParameters OBJECT IDENTIFIER ::= {brzaccVLAirInterface 18} brzaccVLSpectrumAnalysisChannelScanPeriod OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The period of staying on each channel for information gathering when performing Spectrum analysis. Range: 2-30 seconds." ::= { brzaccVLSpectrumAnalysisParameters 1 } brzaccVLSpectrumAnalysisScanCycles OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The number of scanning cycles when performing Spectrum Analysis. Range: 1-100." ::= { brzaccVLSpectrumAnalysisParameters 2 } brzaccVLAutomaticChannelSelection OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), na (255)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. Defines weather the AU/BU shall choose the most noise free channel upon startup after spectrum analysis." ::= { brzaccVLSpectrumAnalysisParameters 3 } brzaccVLSpectrumAnalysisActivation OBJECT-TYPE SYNTAX INTEGER { cancelOperation (1), activateNow (2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Activates spectrum analysis, the unit is automatically reset upon activation." ::= { brzaccVLSpectrumAnalysisParameters 4 } brzaccVLSpectrumAnalysisStatus OBJECT-TYPE SYNTAX INTEGER { inactive (1), currentlyActive (2)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Defines weather the unit is currently under performing a spectrum analysis process." ::= { brzaccVLSpectrumAnalysisParameters 5 } brzaccVLResetSpectrumCounters OBJECT-TYPE SYNTAX INTEGER { cancelOperation (1), resetCounters (2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Resets the spectrum analysis counters." ::= { brzaccVLSpectrumAnalysisParameters 6 } brzaccVLSpectrumAnalysisInformationTable OBJECT-TYPE SYNTAX SEQUENCE OF BrzaccVLSpectrumAnalysisInformationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. The spectrum analysis information table." ::= { brzaccVLSpectrumAnalysisParameters 7 } brzaccVLSpectrumAnalysisInformationEntry OBJECT-TYPE SYNTAX BrzaccVLSpectrumAnalysisInformationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. The spectrum analysis information table entry." INDEX { brzaccVLSpectrumAnalysisInformationTableIdx } ::= { brzaccVLSpectrumAnalysisInformationTable 1 } BrzaccVLSpectrumAnalysisInformationEntry ::= SEQUENCE { brzaccVLSpectrumAnalysisInformationTableIdx INTEGER, brzaccVLSpectrumAnalysisInformationChannel DisplayString, brzaccVLSpectrumAnalysisInformationSignalCount INTEGER, brzaccVLSpectrumAnalysisInformationSignalSNR INTEGER, brzaccVLSpectrumAnalysisInformationSignalWidth INTEGER, brzaccVLSpectrumAnalysisInformationOFDMFrames INTEGER } brzaccVLSpectrumAnalysisInformationTableIdx OBJECT-TYPE SYNTAX INTEGER (1..60) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. A read only table index for a Spectrum Analysis Information entry in the Spectrum Analysis Information Table." ::= { brzaccVLSpectrumAnalysisInformationEntry 1 } brzaccVLSpectrumAnalysisInformationChannel OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The channels in the Spectrum Analysis Information Table. If the unit is currently under spectrum analysis the channels would be those on which the analysis is currently performed. If the unit is in normal mode the channels would be the those on which the last analysis was performed." ::= { brzaccVLSpectrumAnalysisInformationEntry 2 } brzaccVLSpectrumAnalysisInformationSignalCount OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of signals (excluding OFDM frames) detected in the channel. If the unit is currently under spectrum analysis the count would be of the analysis that is currently performed. If the unit is in normal mode the count would be of the last analysis performed." ::= { brzaccVLSpectrumAnalysisInformationEntry 3 } brzaccVLSpectrumAnalysisInformationSignalSNR OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The approximate SNR of the signals (excluding OFDM frames) detected in the channel. If the unit is currently under spectrum analysis the SNR would be of the analysis that is currently performed. If the unit is in normal mode the SNR would be of the last analysis performed." ::= { brzaccVLSpectrumAnalysisInformationEntry 4 } brzaccVLSpectrumAnalysisInformationSignalWidth OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The average width of the signals (excluding OFDM frames) detected in the channel. If the unit is currently under spectrum analysis the width would be of the analysis that is currently performed. If the unit is in normal mode the width would be of the last analysis performed." ::= { brzaccVLSpectrumAnalysisInformationEntry 5 } brzaccVLSpectrumAnalysisInformationOFDMFrames OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of OFDM frames detected in the channel. If the unit is currently under spectrum analysis the count would be of the analysis that is currently performed. If the unit is in normal mode the count would be of the last analysis performed." ::= { brzaccVLSpectrumAnalysisInformationEntry 6 } brzaccVLMaxNumOfAssociationsLimit OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BreezeNET-B products. Shows the limit for the number of SUs that can be associated with the AU. For AU-BS, AU-SA if Data Encryption is enabled, the upper limit is 124, otherwise it is 512. For AUS-BS, AUS-SA with SW version 4.0 and higher the upper limit is 8 or 25 (via licensing). For AUS-BS, AUS-SA with SW version below 4.0 the upper limit is 5. BreezeNET-B products return 65535." ::= { brzaccVLAirInterface 19 } brzaccVLDisassociate OBJECT IDENTIFIER ::= {brzaccVLAirInterface 20} brzaccVLDisassociateAllSUs OBJECT-TYPE SYNTAX INTEGER { cancelOperation (1), disassociateAllSUs(2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. The AU shall disassociate all its associated units." ::= { brzaccVLDisassociate 1 } brzaccVLDisassociateSuByMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. The AU shall disassociate the SU with the configured MAC address." ::= { brzaccVLDisassociate 2 } brzaccVLTxControl OBJECT-TYPE SYNTAX INTEGER { on (1), off(2), ethernetStatusControl(3)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. Tx Control of the AU/BU. Starting with version 4.0 it is run-time. For SW version below 4.0 the unit reset itself. If set to ethernetStatusControl, the unit will not transmit if the Ethernet link is down. This parameter can be configured only via the ethernet port." ::= { brzaccVLAirInterface 21 } brzaccVLLostBeaconsWatchdogThreshold OBJECT-TYPE SYNTAX INTEGER ( 0 | 100..1000 ) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. The number of unsuccessful consecutive transmissions beacons before Internal refresh is performed. 0 means that the lost beacons watchdog is not used and internal refresh is not performed." ::= { brzaccVLAirInterface 22} brzaccVLTransmitPower OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units with SW version 4.0 and higher. The uniform transmit power for all modulation levels. For a specific modulation level the effective transmit power (brzaccVLTxPower) is the minimum between the uniform transmit power and the maximum transmit power for that modulation level." ::= { brzaccVLAirInterface 23 } brzaccVLMaximumTxPower OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to only SU/RB with SW version 4.0 and higher. The Maximum Transmit Power for all modulation levels. The Maximum Transmit Power for a specific modulation level is the minimum between this parameter and the hardware limitation for that modulation level" ::= { brzaccVLAirInterface 24 } brzaccVLCountryCodeParameters OBJECT IDENTIFIER ::= {brzaccVLAirInterface 25} brzaccVLCountryCodeReApply OBJECT-TYPE SYNTAX INTEGER { reapply(1),cancel(2), na(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Re-apply country code parameters." ::= { brzaccVLCountryCodeParameters 1 } -- Service Params -- ============== brzaccVLServiceParameters OBJECT IDENTIFIER ::= {breezeAccessVLMib 7} -- brzaccVLMirCirOption OBJECT-TYPE -- SYNTAX INTEGER {disable (1), -- enable (2), -- na (255)} -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Applicable to AU and SU. Read-only in SU. -- The setting in the AU enables/disables the MIR/CIR support -- feature for all SUs served by the AU." -- ::= { brzaccVLServiceParameters 1 } brzaccVLMirDownlink OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. The Maximum Information Rate (MIR) from AU/BU to SU/RB. MIR must be above brzaccVLCirDownlink value. Range for set: 128 to 2,048 (Kbps) for SU-3 with SW version below 4.0, 128 to 3,072 (Kbps) for SU-3 with SW version 4.0 and higher, 128 to 3,968 (Kbps) for SU-6 with SW version less than 4.0, 128 to 6,016 (Kbps) for SU-6 with SW version greater than 4.0, 128 to 14,976 (Kbps) for SU-24, 128 to 53,888 (Kbps) for SU-BD and SU-54, 128 to 6,912 (Kbps) for RB-14, 128 to 22,016 (Kbps) for RB-28, 128 to 107,904 (Kbps) for RB-100. 128 to 6,016 (Kbps) for SU-I. The actual value (Get) will be the entered value rounded to the nearest multiple of 128 (N*128)." ::= { brzaccVLServiceParameters 2 } brzaccVLMirUplink OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. The Maximum Information Rate (MIR) from SU/RB to AU/BU. MIR must be above brzaccVLCirUplink value. Range for set: 128 to 2,048 (Kbps) for SU-3, 128 to 3,968 (Kbps) for SU-6 with SW version less than 4.0, 128 to 4,096 (Kbps) for SU-6 with SW version greater than 4.0, 128 to 14,976 (Kbps) for SU-24, 128 to 53,888 (Kbps) for SU-BD and SU-54, 128 to 6,912 (Kbps) for RB-14, 128 to 22,016 (Kbps) for RB-28, 128 to 107,904 (Kbps) for RB-100. 128 to 2,048 (Kbps) for SU-I. The actual value (Get) will be the entered value rounded to the nearest multiple of 128 (N*128)." ::= { brzaccVLServiceParameters 3 } brzaccVLCirDownlink OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU only. Not applicable to BreezeNET-B products. The Committed Information Rate (CIR) from AU to SU. CIR must be below brzaccVLMirDownlink value. Range for Set: 0 to 2,048 (Kbps) for SU-3 with SW version below 4.0, 0 to 3,072 (Kbps) for SU-3 with SW version 4.0 and higher, 0 to 3,968 (Kbps) for SU-6 with SW version less than 4.0, 0 to 6,016 (Kbps) for SU-6 with SW version greater than 4.0 0 to 14,976 (Kbps) for SU-24, 0 to 45,056 (Kbps) for SU-BD and SU-54. 0 to 6,016 (Kbps) for SU-I. The actual value (Get) will be the entered value rounded to the nearest multiple of 128 (N*128). BreezeNET-B products will return 65535." ::= { brzaccVLServiceParameters 4 } brzaccVLCirUplink OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU only. Not applicable to BreezeNET-B products. The Committed Information Rate (CIR) from SU to AU. CIR must be below brzaccVLMirUplink value. Range for Set: 0 to 2,048 (Kbps) for SU-3, 0 to 3,968 (Kbps) for SU-6 with SW version less than 4.0, 0 to 4,096 (Kbps) for SU-6 with SW version greater than 4.0, 0 to 14,976 (Kbps) for SU-24, 0 to 45,056 (Kbps) for SU-BD and SU-54. 0 to 2,048 (Kbps) for SU-I. The actual value (Get) will be the entered value rounded to the nearest multiple of 128 (N*128). BreezeNET-B products will return 65535." ::= { brzaccVLServiceParameters 5 } brzaccVLMaxDelay OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU only. Not applicable to BreezeNET-B products. The maximal time packets may be delayed by the CIR\MIR mechanism. Above the configured maximal period the packets are discarded. Range: 300 to 10000 milliseconds. BreezeNET-B products return 65535." ::= { brzaccVLServiceParameters 6 } brzaccVLMaxBurstDuration OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU and SU. Not applicable to BreezeNET-B products. The maximum time during which inactivity bonus time can be accumulated for future burst transmissions. Range: 0 to 2000 milliseconds. BreezeNET-B products return 65535" ::= { brzaccVLServiceParameters 7 } brzaccVLGracefulDegradationLimit OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BreezeNET-B products. The maximum limit for activating the graceful degradation algorithm. Range: 0 to 70% rate of the CIR. BreezeNET-B products return 255." ::= { brzaccVLServiceParameters 8 } brzaccVLMirOnlyOption OBJECT-TYPE SYNTAX INTEGER {disable (1), enable (2), na (255)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BreezeNET-B products. When brzaccMirOnly is enabled, it overrides the CIR/MIR algorithm for determining actual information rate and forces the algorithm to operate with MIR parameter settings only. When enabled, the Graceful Degradation algorithm is disabled." ::= { brzaccVLServiceParameters 9 } brzaccVLTrafficPrioritization OBJECT IDENTIFIER ::= {brzaccVLServiceParameters 10} brzaccVLTrafficPriVLAN OBJECT IDENTIFIER ::= {brzaccVLTrafficPrioritization 1} brzaccVLVLANPriorityThreshold OBJECT-TYPE SYNTAX INTEGER (1..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. If the VLAN Priority's value of the frame is less than or equal to this threshold the frame will get LOW priority, otherwise the frame will get HIGH priority. Untagged frames will get LOW priority" ::= { brzaccVLTrafficPriVLAN 1 } brzaccVLTrafficPriIPToS OBJECT IDENTIFIER ::= {brzaccVLTrafficPrioritization 2} brzaccVLToSPrioritizationOption OBJECT-TYPE SYNTAX INTEGER {disable(1), ipPrecedence(2), dSCP(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Disable/Enable IP ToS prioritization and choose the interpretation of the IP ToS field from IP header. ipPrecedence(2): The IP ToS field is defined by RFC791. In this case the prioritization will be done using the Precedence sub-field of IP ToS. This sub-field has 3 bits, so it can be between 0 and 7. dSCP(3): The IP ToS field is defined by RFC2474. In this case the prioritization will be done using the DSCP sub-field. The size of the sub-field is 6 bits, so the range is 0 to 63." ::= { brzaccVLTrafficPriIPToS 1 } brzaccVLIPPrecedenceThreshold OBJECT-TYPE SYNTAX INTEGER (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The threshold of Precedence sub-field of IP ToS field from IP Header (RFC791) to be used when the ToS Prioritization Option is set to IP Precedence. If the Precedence sub-field of a frame is less than or equal to this threshold the frame will have LOW priority, otherwise it will get HIGH priority." ::= { brzaccVLTrafficPriIPToS 2 } brzaccVLIPDSCPThreshold OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The threshold of DSCP sub-field of IP ToS field from IP Header (RFC2474) to be used when ToS Prioritization Option is set to DSCP. If the DSCP sub-field of a frame is less than or equal to this threshold the frame will have LOW priority, otherwise it will get HIGH priority." ::= { brzaccVLTrafficPriIPToS 3 } brzaccVLTrafficPriUdpTcpPortRange OBJECT IDENTIFIER ::= {brzaccVLTrafficPrioritization 3} brzaccVLUdpTcpPortRangePrioritizationOption OBJECT-TYPE SYNTAX INTEGER {disable(1), udpOnly(2), tcpOnly(3), udpANDtcp(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Disable/Enable Prioritization using UDP and/or TCP Port Ranges. udpOnly(2) : prioritization will be done only for UDP packets tcpOnly(3) : prioritization will be done only for TCP packets udpANDtcp(4): prioritization will be done for UDP and TCP packets" ::= { brzaccVLTrafficPriUdpTcpPortRange 1 } brzaccVLUdpPortRangeConfig OBJECT IDENTIFIER ::= {brzaccVLTrafficPriUdpTcpPortRange 2} brzaccVLUdpPortPriRTPRTCP OBJECT-TYPE SYNTAX INTEGER {rtpANDrtcp(1),rtpOnly(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicale to all units. RTP/RTCP ports prioritization option for UDP packets. rtpANDrtcp(1): the possible RTP and RTCP packet with destination port in the defined port ranges will get HIGH priority rtpOnly(2): only possible RTP packet (packet with even destination port ) with destination port in the defined port ranges will get HIGH priority." ::= { brzaccVLUdpPortRangeConfig 1 } brzaccVLUdpPortRangeNum OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of entries in the UDP Port Range Table" ::= { brzaccVLUdpPortRangeConfig 2 } brzaccVLUdpPortRangeTable OBJECT-TYPE SYNTAX SEQUENCE OF BrzaccVLUdpPortRangeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. A table of UDP port ranges use for prioritization. The user can define up to 64 ranges. An entry is empty if start is 65535 and end is 0" ::= { brzaccVLUdpPortRangeConfig 3 } brzaccVLUdpPortRangeEntry OBJECT-TYPE SYNTAX BrzaccVLUdpPortRangeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. A UDP Port Ranges Table entry." INDEX { brzaccVLUdpPortRangeIdx } ::= { brzaccVLUdpPortRangeTable 1 } BrzaccVLUdpPortRangeEntry ::= SEQUENCE { brzaccVLUdpPortRangeStart INTEGER, brzaccVLUdpPortRangeEnd INTEGER, brzaccVLUdpPortRangeIdx INTEGER } brzaccVLUdpPortRangeStart OBJECT-TYPE SYNTAX INTEGER(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Start port of an UDP Port Range" ::= { brzaccVLUdpPortRangeEntry 1 } brzaccVLUdpPortRangeEnd OBJECT-TYPE SYNTAX INTEGER(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. End port of an UDP Port Range" ::= { brzaccVLUdpPortRangeEntry 2 } brzaccVLUdpPortRangeIdx OBJECT-TYPE SYNTAX INTEGER(1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. UDP Port Range Entry's index " ::= { brzaccVLUdpPortRangeEntry 3 } brzaccVLUdpPortRangeAdd OBJECT-TYPE SYNTAX DisplayString (SIZE(0..250)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Add port range(s) to UDP Port Ranges Table. Get operation will return the empty string. A range is defined - or where is the Start Port of the range and is the End Port. If only is specified the range is -. The value of and are between 0..65535. The user can add several ranges using a comma to separate between ranges. Example: 10-256,99,987-900" ::= { brzaccVLUdpPortRangeConfig 4 } brzaccVLUdpPortRangeDelete OBJECT-TYPE SYNTAX DisplayString (SIZE(0..250)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Delete port range(s) from UDP Port Ranges Table. Get operation will return the empty string. A range is defined - or where is the Start Port of the range and is the End Port. If only is specified the range is -. The value of and are between 0..65535. The user can delete several ranges using a comma to separate between ranges. Example: 10-256,99,987-900" ::= { brzaccVLUdpPortRangeConfig 5 } brzaccVLUdpPortRangeDeleteAll OBJECT-TYPE SYNTAX INTEGER { deleteAll(1), cancelOperation(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Delete all entries form UDP Port Ranges Table. Get operation will return 1" ::= { brzaccVLUdpPortRangeConfig 6 } brzaccVLTcpPortRangeConfig OBJECT IDENTIFIER ::= {brzaccVLTrafficPriUdpTcpPortRange 3} brzaccVLTcpPortPriRTPRTCP OBJECT-TYPE SYNTAX INTEGER {rtpANDrtcp(1),rtpOnly(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. RTP/RTCP ports prioritization option for TCP packets. rtpANDrtcp(1): the possible RTP and RTCP packet with destination port in the defined port ranges will get HIGH priority rtpOnly(2): only possible RTP packet (packet with even destination port )" ::= { brzaccVLTcpPortRangeConfig 1 } brzaccVLTcpPortRangeNum OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of entries in the TCP Port Range Table" ::= { brzaccVLTcpPortRangeConfig 2 } brzaccVLTcpPortRangeTable OBJECT-TYPE SYNTAX SEQUENCE OF BrzaccVLTcpPortRangeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of TCP Port Ranges use for prioritization. The user can define up to 64 ranges. An entry is empty if start is 65535 and end is 0" ::= { brzaccVLTcpPortRangeConfig 3 } brzaccVLTcpPortRangeEntry OBJECT-TYPE SYNTAX BrzaccVLTcpPortRangeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. A TCP Port Ranges Table entry." INDEX { brzaccVLTcpPortRangeIdx } ::= { brzaccVLTcpPortRangeTable 1 } BrzaccVLTcpPortRangeEntry ::= SEQUENCE { brzaccVLTcpPortRangeStart INTEGER, brzaccVLTcpPortRangeEnd INTEGER, brzaccVLTcpPortRangeIdx INTEGER } brzaccVLTcpPortRangeStart OBJECT-TYPE SYNTAX INTEGER(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Start port of a TCP Port Range" ::= { brzaccVLTcpPortRangeEntry 1 } brzaccVLTcpPortRangeEnd OBJECT-TYPE SYNTAX INTEGER(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. End port of a TCP Port Range" ::= { brzaccVLTcpPortRangeEntry 2 } brzaccVLTcpPortRangeIdx OBJECT-TYPE SYNTAX INTEGER(1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. TCP Port Range Entry's index" ::= { brzaccVLTcpPortRangeEntry 3 } brzaccVLTcpPortRangeAdd OBJECT-TYPE SYNTAX DisplayString (SIZE(0..250)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Add port range(s) to TCP Port Ranges Table. Get operation will return the empty string. A range is defined - or where is the Start Port of the range and is the End Port. If only is specified the range is -. The value of and are between 0..65535. The user can add several ranges using comma to separate between ranges. Example: 10-256,99,987-900" ::= { brzaccVLTcpPortRangeConfig 4 } brzaccVLTcpPortRangeDelete OBJECT-TYPE SYNTAX DisplayString (SIZE(0..250)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Delete port range(s) from TCP Port Ranges Table. Get operation will return the empty string. A range is defined - or where is the Start Port of the range and is the End Port. If only is specified the range is -. The value of and are between 0..65535. The user can delete several ranges using comma to separate between ranges. Example: 10-256,99,987-900" ::= { brzaccVLTcpPortRangeConfig 5 } brzaccVLTcpPortRangeDeleteAll OBJECT-TYPE SYNTAX INTEGER { deleteAll(1), cancelOperation(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Delete all entries form TCP Port Ranges Table Get operation will return 1" ::= { brzaccVLTcpPortRangeConfig 6 } brzaccVLWirelessLinkPrioritization OBJECT IDENTIFIER ::= {brzaccVLTrafficPrioritization 4} brzaccVLWirelessLinkPrioritizationOption OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2), na(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100. Enable/disable the traffic prioritization over the Wireless Link" ::= { brzaccVLWirelessLinkPrioritization 1} brzaccVLlowPriorityAIFS OBJECT-TYPE SYNTAX INTEGER (3..254) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100. Applicable only if the Wireless Link Prioritization Option is enabled. Define the AIFS (Arbitration Inter-frame Space) that will be used for transmitting Low Priority Traffic" ::= { brzaccVLWirelessLinkPrioritization 2} brzaccVLHWRetriesHighPriority OBJECT-TYPE SYNTAX INTEGER (0..14) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100. Applicable only if the Wireless Link Prioritization Option is enabled. Defines the Maximum number of HW Retries for a unicast data packet that has High Priority" ::= { brzaccVLWirelessLinkPrioritization 3} brzaccVLHWRetriesLowPriority OBJECT-TYPE SYNTAX INTEGER (0..14) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100. Applicable only if the Wireless Link Prioritization Option is enabled. Defines the Maximum number of HW Retries for a unicast data packet that has Low Priority" ::= { brzaccVLWirelessLinkPrioritization 4} brzaccVLAUBurstDurationHighPriority OBJECT-TYPE SYNTAX INTEGER (0..40) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100. Applicable only if the Wireless Link Prioritization Option is enabled. Defines the Maximum duration of burst that can be done by AU with High Priority packets. The time is given in 250 microseconds units" ::= { brzaccVLWirelessLinkPrioritization 5} brzaccVLAUBurstDurationLowPriority OBJECT-TYPE SYNTAX INTEGER (0..40) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100. Applicable only if the Wireless Link Prioritization Option is enabled. Defines the Maximum duration of burst that can be done by AU with Low Priority packets. The time is given in 250 microseconds units" ::= { brzaccVLWirelessLinkPrioritization 6} brzaccVLSUBurstDurationHighPriority OBJECT-TYPE SYNTAX INTEGER (0..40) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100. Applicable only if the Wireless Link Prioritization Option is enabled. Defines the Maximum duration of burst that can be done by SU/RB with High Priority packets. The parameter is configurable in AU and the SUs/RB will learn it form AU/BU. The time is given in 250 microseconds units" ::= { brzaccVLWirelessLinkPrioritization 7} brzaccVLSUBurstDurationLowPriority OBJECT-TYPE SYNTAX INTEGER (0..40) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100. Applicable only if the Wireless Link Prioritization Option is enabled. Defines the Maximum duration of burst that can be done by SU/RB with High Priority packets. The parameter is configurable in AU/BU and the SUs/RB will learn it from AU/BU. The time is given in 250 microseconds units" ::= { brzaccVLWirelessLinkPrioritization 8} --DRAP BEGIN brzaccVLDrap OBJECT IDENTIFIER ::= { brzaccVLServiceParameters 11 } brzaccVLDrapSupport OBJECT-TYPE SYNTAX INTEGER {disable(1), enable(2), na(255)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU. Not applicable to BreezeNET B products Disable/Enable the DRAP feature" ::= { brzaccVLDrap 1 } brzaccVLDrapUdpPort OBJECT-TYPE SYNTAX INTEGER (8000..8200) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU when DRAP support is enabled. Not applicable to BreezeNET B products. The UDP port used for the DRAP server" ::= { brzaccVLDrap 2 } brzaccVLDrapMaxNumberOfVoiceCalls OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU when DRAP support is enabled. Not applicable to BreezeNET B products. The maximum number of voice calls that can be supported by the AU" ::= { brzaccVLDrap 3 } brzaccVLDrapTTL OBJECT-TYPE SYNTAX INTEGER (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU when DRAP support is enabled. Not applicable to BreezeNET B products. The maximum time between two allocation requests" ::= { brzaccVLDrap 4 } brzaccVLDrapNoOfActiveVoiceCalls OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU when DRAP support is enabled. Not applicable to BreezeNET B products. The current total number of active voice calls." ::= { brzaccVLDrap 5 } --DRAP END brzaccVLLowPriorityTrafficMinimumPercent OBJECT-TYPE SYNTAX INTEGER (0..100) MAX-ACCESS read-write STATUS current DESCRIPTION "The minimum percent of the traffic rate that is allocated to the low priority traffic" ::= { brzaccVLServiceParameters 12 } brzaccVLSUPMirDownlink OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. The Maximum Information Rate (MIR) from AU to SUP. Range for set: 128 to 12,032 (Kbps). The actual value (Get) will be the entered value rounded to the nearest multiple of 128 (N*128)." ::= { brzaccVLServiceParameters 13 } brzaccVLMIRThresholdPercent OBJECT-TYPE SYNTAX INTEGER (0..100) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. MIR Threshold Percent" ::= { brzaccVLServiceParameters 14 } -- User Filtering Params -- ===================== brzaccVLUserFilterParams OBJECT IDENTIFIER ::= {breezeAccessVLMib 8} brzaccVLUserFilterOption OBJECT-TYPE SYNTAX INTEGER { disable (1), ipOnly (2), userDefinedAddrOnly (3), pPPoEOnly (4), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. Defines user-filtering options. disable: No filtering. iPOnly: Only IP protocol frames pass. userDefinedAddrOnly: Only ip frames to/from user defined IP addresses pass. pPPoE Only: Only PPPoE frames pass." ::= { brzaccVLUserFilterParams 1 } brzaccVLIpFilterTable OBJECT-TYPE SYNTAX SEQUENCE OF BrzaccVLIpFilterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to SU/RB only. An IP Filter Table of up to 8 user defined addresses, or address groups, to be used if the selected User Filtering option is userDefinedAddrOnly." ::= { brzaccVLUserFilterParams 2 } brzaccVLIpFilterEntry OBJECT-TYPE SYNTAX BrzaccVLIpFilterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to SU/RB only. An IP Filter Table entry." INDEX { brzaccVLIpFilterIdx } ::= { brzaccVLIpFilterTable 1 } BrzaccVLIpFilterEntry ::= SEQUENCE { brzaccVLIpID IpAddress, brzaccVLMaskID IpAddress, brzaccVLIpFilterRange INTEGER, brzaccVLIpFilterIdx INTEGER } brzaccVLIpID OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. An IP address of an IP Filter Table entry." ::= { brzaccVLIpFilterEntry 1 } brzaccVLMaskID OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. An IP Mask of an IP Filter Table entry. Either a mask or a range, but not both can be used to define an address group. If the range is other than 0, than the mask is ignored and only the range value is used to define the address group." ::= { brzaccVLIpFilterEntry 2 } brzaccVLIpFilterRange OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. An addresses range for the IP Filter Table entry. The first address in the range is the IP address. O means that the range is not used. Either a mask or a range, but not both can be used to define an address group. If the range is other than 0, than the mask is ignored and only the range value is used to define the address group. Range: 0 to 255." ::= { brzaccVLIpFilterEntry 3 } brzaccVLIpFilterIdx OBJECT-TYPE SYNTAX INTEGER (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. A table index for the IP Filter Table entry." ::= { brzaccVLIpFilterEntry 4 } brzaccVLDeleteOneUserFilter OBJECT-TYPE SYNTAX INTEGER { deletefirstEntry (1), deletesecondEntry (2), deletethirdEntry (3), deletefourthEntry (4), deletefifthEntry (5), deletesixthEntry (6), deleteseventhEntry(7), deleteeighthEntry (8), cancelOperation (9), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. Deletes a single selected entry from the IP Filter Table." ::= { brzaccVLUserFilterParams 3 } brzaccVLDeleteAllUserFilters OBJECT-TYPE SYNTAX INTEGER { deleteAll (1), cancelOperation (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. Deletes all entries from the IP Filter Table." ::= { brzaccVLUserFilterParams 4 } brzaccVLDHCPUnicastOverrideFilter OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. Enables or disables the unicast DHCP messages, overriding the IP Filtering option." ::= { brzaccVLUserFilterParams 5 } -- Security Params -- ================== brzaccVLSecurityParameters OBJECT IDENTIFIER ::= {breezeAccessVLMib 9} brzaccVLAuthenticationAlgorithm OBJECT-TYPE SYNTAX INTEGER {openSystem(1) , sharedKey(2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Enables/disables the authentication encryption option. openSystem: Authentication messages are not encrypted. sharedKey : Authentication messages are encrypted " ::= { brzaccVLSecurityParameters 1 } brzaccVLSUDefaultKeyID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. The key to be used for encryption of authentication messages and/or data. Range: 1 to 4. " ::= { brzaccVLSecurityParameters 2 } brzaccVLDataEncryptionOption OBJECT-TYPE SYNTAX INTEGER {disable(1) , enable(2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Enables/disables the data encryption option. " ::= { brzaccVLSecurityParameters 3 } brzaccVLAUDefaultMulticastKeyID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. The key to be used for encryption of multicasts and broadcasts." ::= { brzaccVLSecurityParameters 4 } brzaccVLSecurityMode OBJECT-TYPE SYNTAX INTEGER {wep(1) , aesOCB(2), fips197(3)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The fips197 option is applicable only to units with a license to use FIPS 197 algorithm. The encryption algorithm to be used for authentication messages and/or data encryption." ::= { brzaccVLSecurityParameters 5 } brzaccVLAuthenticationPromiscuousMode OBJECT-TYPE SYNTAX INTEGER {disable(1) , enable(2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. Enables/disable the promiscuous mode allowing authentication of and communication with all SUs/RB regardless of their security parameters." ::= { brzaccVLSecurityParameters 6 } brzaccVLKey1 OBJECT-TYPE SYNTAX DisplayString (SIZE(32)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Key number 1. Accessible only with SNMP Write Community String (administrator password). Valid values: 32 hexadecimal digits." ::= { brzaccVLSecurityParameters 7 } brzaccVLKey2 OBJECT-TYPE SYNTAX DisplayString (SIZE(32)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Key number 2. Accessible only with SNMP Write Community String (administrator password). Valid values: 32 hexadecimal digits." ::= { brzaccVLSecurityParameters 8 } brzaccVLKey3 OBJECT-TYPE SYNTAX DisplayString (SIZE(32)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Key number 3. Accessible only with SNMP Write Community String (administrator password). Valid values: 32 hexadecimal digits." ::= { brzaccVLSecurityParameters 9 } brzaccVLKey4 OBJECT-TYPE SYNTAX DisplayString (SIZE(32)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Key number 4. Accessible only with SNMP Write Community String (administrator password). Valid values: 32 hexadecimal digits." ::= { brzaccVLSecurityParameters 10 } brzaccVLSecurityModeSupport OBJECT-TYPE SYNTAX INTEGER (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Returns types of encryption that are supported. 0 - no encryption 1 - WEP 2 - AES OCB 3 - WEP and AES OCB 4 - FIPS-197 5 - FIPS-197 and WEP 6 - FIPS-197 and AES OCB 7 - FIPS-197, AES OCB and WEP" ::= { brzaccVLSecurityParameters 12 } --brzaccVLSecurityPermission OBJECT IDENTIFIER ::= {brzaccVLSecurityParameters 12} -- -- brzaccVLDataEncryptionPermission OBJECT-TYPE -- SYNTAX INTEGER {permitted(1), notPermitted(2)} -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "." -- ::= { brzaccVLSecurityPermission 1 } -- -- brzaccVLEncryptionByAESPermission OBJECT-TYPE -- SYNTAX INTEGER {permitted(1), notPermitted(2)} -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "." -- ::= { brzaccVLSecurityPermission 2 } -- -- -- brzaccVLAuthenticationBySharedKeyAlgorithmPermission OBJECT-TYPE -- SYNTAX INTEGER {permitted(1), notPermitted(2)} -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "." -- ::= { brzaccVLSecurityPermission 3 } -- Performance Params -- ================== brzaccVLPerformanceParams OBJECT IDENTIFIER ::= {breezeAccessVLMib 10} brzaccVLRTSThreshold OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU and AU. Not applicable to BreezeNET-B products. The minimum frame size that requires an RTS/CTS handshake. Range: For units bearing SW version 3.0 and above: 20 to 3400 bytes, for previous SW versions 20 to 1600 bytes. BreezeNET-B products return 65535." ::= { brzaccVLPerformanceParams 1 } brzaccVLMinContentionWindow OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU and AU. For units bearing SW version 4.0 and above applicable to BreezeNET-B products, for previous SW versions not applicable to BreezeNET-B products. The initial value to be used by the contention window calculation algorithm. Value must be 0 or power of 2 minus 1 (7,15,31...). Range: 0 to 1023, excluding 1 and 3. BreezeNET-B products with SW version below 4.0 return 65535." ::= { brzaccVLPerformanceParams 3 } brzaccVLMaxContentionWindow OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU and AU. For units bearing SW version 4.0 and above applicable to BreezeNET-B products, for previous SW versions not applicable to BreezeNET-B products. The maximum value to be used by the contention window calculation algorithm. Value must be power of 2 minus 1 (7,15,31...) Range: 7 to 1023." ::= { brzaccVLPerformanceParams 4 } brzaccVLMaximumModulationLevel OBJECT-TYPE SYNTAX INTEGER { level1 (1), level2 (2), level3 (3), level4 (4), level5 (5), level6 (6), level7 (7), level8 (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. If the Adaptive Modulation algorithm is enabled, it sets the Maximum Modulation Level to be used. If The Modulation algorithm is disabled, it sets the Fixed Modulation Level to be used. The range is 1 to 8. 8 is not applicable for units with HW revision A." ::= { brzaccVLPerformanceParams 5 } brzaccVLMulticastModulationLevel OBJECT-TYPE SYNTAX INTEGER { level1 (1), level2 (2), level3 (3), level4 (4), level5 (5), level6 (6), level7 (7), level8 (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. The modulation level for multicast and broadcast data frames. The range is 1 to 8. 8 is not applicable for units with HW revision A." ::= { brzaccVLPerformanceParams 6 } brzaccVLAvgSNRMemoryFactor OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The weight of history in average SNR calculation. The higher is the value, the higher is the weight of history. Range: -1 (Disregard History) to 32." ::= { brzaccVLPerformanceParams 7 } brzaccVLHardwareRetries OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Not applicable if Wireless Link Prioritization is enabled. The maximum number of trials to transmit an unacknowledged frame in each Hardware Retrial phase. Range : 1 to 14." ::= { brzaccVLPerformanceParams 8 } brzaccVLAdaptiveModulationParams OBJECT IDENTIFIER ::= {brzaccVLPerformanceParams 9} brzaccVLAdaptiveModulationAlgorithmOption OBJECT-TYPE SYNTAX INTEGER { disable (1) , enable (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Enables/disables the adaptive modulation level decision mechanism." ::= { brzaccVLAdaptiveModulationParams 1 } brzaccVLSoftwareRetrySupport OBJECT-TYPE SYNTAX INTEGER { disable (1) , enable (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Read-only for units with version 2.0. Not applicable for units with SW version 3.0 and higher. The status of the Software Retry mechanism. Enabled when the Adaptive Modulation algorithm is enabled and the Burst Mode Option is disabled. Otherwise it is disabled." ::= { brzaccVLAdaptiveModulationParams 2 } brzaccVLNumOfSoftwareRetries OBJECT-TYPE SYNTAX INTEGER { na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Read-only for units with version 2.0. Not applicable for units with SW version 3.0 and higher. The maximum number of times to use the Software Retry mechanism when it is enabled." ::= { brzaccVLAdaptiveModulationParams 3 } brzaccVLMinIntervalBetweenAdaptiveModulationAlgorithmMessages OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable all units. The minimum interval between two consecutive AU/BU to SU/RB messages. Range: 1 to 3600 (Sec)." ::= { brzaccVLAdaptiveModulationParams 4 } brzaccVLAdaptiveModulationDecisionThresholds OBJECT-TYPE SYNTAX INTEGER { normal (1) , high (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Defines the setting of thresholds for the rate decision algorithm. high (2) should typically be used when the SNR is lower than 13dB." ::= { brzaccVLAdaptiveModulationParams 5 } brzaccVLBurstMode OBJECT IDENTIFIER ::= {brzaccVLPerformanceParams 10} brzaccVLBurstModeOption OBJECT-TYPE SYNTAX INTEGER { disable (1) , enable (2), blocked(3), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Applicable only if Burst Mode Option is supported by country specific parameters of the Sub Band. Not applicable if Wireless Link Prioritization is enabled. Enables/disable burst mode operation. In SU/RB with HW Revision B or lower blocked(3) value is returned when Security Mode is Wep , Data Encryption Option is Enabled and Burst option is Enabled. In AU/BU with HW Revision B or lower blocked(3) value is returned when Dfs Option is Enabled and Burst mode is enabled." ::= { brzaccVLBurstMode 1 } brzaccVLBurstInterval OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Not applicable if Wireless Link Prioritization is enabled. Burst mode interval in milliseconds. Range: 1 to the maximum value as defined in the country specific parameters of the Sub Band (milliseconds)." ::= { brzaccVLBurstMode 2 } brzaccVLConcatenationParameters OBJECT IDENTIFIER ::= {brzaccVLPerformanceParams 11} brzaccVLConcatenationOption OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), na (255)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Defines the Concatenation option." ::= { brzaccVLConcatenationParameters 1 } brzaccVLConcatenationMaximumNumberOfFrames OBJECT-TYPE SYNTAX INTEGER (2..8) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units with SW version 3.X . Not applicable for version 4.0 and higher. Defines the maximum numbers of frames that can be concatenated. Range:2 to 8 (frames)." ::= { brzaccVLConcatenationParameters 2 } brzaccVLConcatenationMaxFrameSize OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Defines the maximum size of a concatenated frame. Range: 256 to 2200 (bytes) for BreezeNET-B products BU/RB14 BU/RB28, or for AU/SU with HW revision A or B. 256 to 4032 (bytes) for AU/SU with HW Revision C or higher and BreezeNET-B products BU/RB100." ::= { brzaccVLConcatenationParameters 3 } -- Site Survey Params -- ================== brzaccVLSiteSurvey OBJECT IDENTIFIER ::= {breezeAccessVLMib 11} brzaccVLAverageReceiveSNR OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. The average Signal to Noise Ratio of received frames." ::= { brzaccVLSiteSurvey 1 } -- Traffic Counters -- ================ brzaccVLTrafficStatistics OBJECT IDENTIFIER ::= {brzaccVLSiteSurvey 2} brzaccVLResetTrafficCounters OBJECT-TYPE SYNTAX INTEGER { reset (1),cancel(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Resets the traffic counters." ::= { brzaccVLTrafficStatistics 1 } brzaccVLEthCounters OBJECT IDENTIFIER ::= {brzaccVLTrafficStatistics 2} brzaccVLWirelessLinkCounters OBJECT IDENTIFIER ::= {brzaccVLTrafficStatistics 3} brzaccVLWirelessLinkEvents OBJECT IDENTIFIER ::= {brzaccVLTrafficStatistics 4} brzaccVLPerModulationLevelCounters OBJECT IDENTIFIER ::= {brzaccVLTrafficStatistics 5} brzaccVLResetPerModulationLevelCounters OBJECT-TYPE SYNTAX INTEGER { resetCounters(1) , cancel (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Resets the per-Modulation Level counters ." ::= { brzaccVLPerModulationLevelCounters 1 } brzaccVLSUPerModulationLevelCountersTable OBJECT-TYPE SYNTAX SEQUENCE OF BrzaccVLSUPerModulationLevelCountersEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to SU/RB. Per Rate Counters table." ::= { brzaccVLPerModulationLevelCounters 2 } brzaccVLSUPerModulationLevelCountersEntry OBJECT-TYPE SYNTAX BrzaccVLSUPerModulationLevelCountersEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to SU/RB. An entry in the Per modulation Counters table." INDEX { brzaccVLSUPerModulationLevelCountersTableIdx } ::= { brzaccVLSUPerModulationLevelCountersTable 1 } BrzaccVLSUPerModulationLevelCountersEntry ::= SEQUENCE { brzaccVLSUPerModulationLevelCountersTableIdx INTEGER, brzaccVLSUPerModulationLevelCountersApplicableModLevel INTEGER, brzaccVLSUPerModulationLevelCountersTxSuccess Counter32, brzaccVLSUPerModulationLevelCountersTxFailed Counter32 } brzaccVLSUPerModulationLevelCountersTableIdx OBJECT-TYPE SYNTAX INTEGER (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB. An index of an entry in the Per modulation level Counters table." ::= { brzaccVLSUPerModulationLevelCountersEntry 1 } brzaccVLSUPerModulationLevelCountersApplicableModLevel OBJECT-TYPE SYNTAX INTEGER { modLevel-1 (1), modLevel-2 (2), modLevel-3 (3), modLevel-4 (4), modLevel-5 (5), modLevel-6 (6), modLevel-7 (7), modLevel-8 (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB. The applicable modulation level of the entry in the Per modulation level Counters table. Modulation Level 8 is not applicable for units with HW revision A." ::= { brzaccVLSUPerModulationLevelCountersEntry 2 } brzaccVLSUPerModulationLevelCountersTxSuccess OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB. The total number of successfully transmitted unicasts at the applicable modulation level." ::= { brzaccVLSUPerModulationLevelCountersEntry 3 } brzaccVLSUPerModulationLevelCountersTxFailed OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB. The total number of dropped frames at the applicable Modulation Level." ::= { brzaccVLSUPerModulationLevelCountersEntry 4 } brzaccVLAverageModulationLevel OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB. The average modulation level for successful transmission (rounded to nearest integer) since last reset of the Per Modulation Level counters. Range: 1 to 8." ::= { brzaccVLPerModulationLevelCounters 3 } brzaccVLTotalRxFramesViaEthernet OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Total number of frames received via the Ethernet port." ::= { brzaccVLEthCounters 1 } brzaccVLTxWirelessToEthernet OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Total number of frames transmitted to the Ethernet port." ::= { brzaccVLEthCounters 2 } brzaccVLTxFramesToWireless OBJECT IDENTIFIER ::= {brzaccVLWirelessLinkCounters 1} brzaccVLAUBeaconsToWireless OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The number of beacons transmitted to the wireless media." ::= { brzaccVLTxFramesToWireless 1 } -- brzaccVLOtherMngFramesToWireless OBJECT-TYPE -- SYNTAX Counter32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "Applicable to AU and SU. -- The number of management frames transmitted to the wireless media. -- In AU, this count does not include Beacons." -- ::= { brzaccVLTxFramesToWireless 2 } brzaccVLDataAndOtherMngFramesToWireless OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The number of data and management frames transmitted to the wireless media. The count includes one count for each data frame transmitted successfully (excluding retransmissions)." ::= { brzaccVLTxFramesToWireless 3 } brzaccVLTotalTxFramesToWireless OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of frames transmitted to the wireless media. The count includes one count for each data frame that was transmitted successfully (excluding retransmissions), and also the number of transmitted control and management frames, including beacons." ::= { brzaccVLTxFramesToWireless 4 } brzaccVLTotalTransmittedUnicasts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The total number of unicast frames successfully transmitted to the wireless media, excluding retransmissions." ::= { brzaccVLTxFramesToWireless 5 } brzaccVLTotalTransmittedConcatenatedFramesDouble OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all products. The total number of double concatenated frames successfully transmitted to the wireless media, excluding retransmissions." ::= { brzaccVLTxFramesToWireless 6 } brzaccVLTotalTransmittedConcatenatedFramesSingle OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all products. The total number of double concatenated frames successfully transmitted to the wireless media, excluding retransmissions." ::= { brzaccVLTxFramesToWireless 7 } brzaccVLTotalTransmittedConcatenatedFramesMore OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all products. The total number of concatenated frames with more then two frames successfully transmitted to the wireless media, excluding retransmissions." ::= { brzaccVLTxFramesToWireless 8 } brzaccVLTotalRxFramesFromWireless OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The total number of frames that were received from the wireless media. The count includes data and control and management frames, including beacons received from the AU/BU. The count does not include frames that were discarded internally, bad frames and duplicate frames." ::= { brzaccVLWirelessLinkCounters 2 } brzaccVLTotalRetransmittedFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The total number of retransmissions of data frames (counts all unsuccessful transmissions/retransmissions)." ::= { brzaccVLWirelessLinkCounters 3 } brzaccVLFramesDropped OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of dropped frames. The frames that were retransmitted to the extent of the maximum allowed number of retransmissions without being acknowledged.." ::= { brzaccVLWirelessLinkCounters 4 } brzaccVLDataFramesSubmittedToBridge OBJECT IDENTIFIER ::= {brzaccVLWirelessLinkCounters 5} brzaccVLFramesSubmittedViaHighQueue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Frames submitted to the internal bridge via the High priority queue. for transmission to the wireless media." ::= { brzaccVLDataFramesSubmittedToBridge 1 } brzaccVLFramesSubmittedViaMidQueue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Frames submitted to the internal bridge via the Mid priority queue for transmission to the wireless media." ::= { brzaccVLDataFramesSubmittedToBridge 2 } brzaccVLFramesSubmittedViaLowQueue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Frames submitted to the internal bridge via the Low priority queue for transmission to the wireless media." ::= { brzaccVLDataFramesSubmittedToBridge 3 } brzaccVLTotalNoOfDataFramesSubmitted OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The total number of data frames submitted to the internal bridge for transmission to the wireless media." ::= { brzaccVLDataFramesSubmittedToBridge 4 } brzaccVLTotalRecievedDataFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The total number of data frames received from the wireless media, including duplicate frames." ::= { brzaccVLWirelessLinkCounters 6 } brzaccVLRecievedBadFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of frames received from the wireless media with errors (CRC errors)." ::= { brzaccVLWirelessLinkCounters 7 } brzaccVLNoOfDuplicateFramesDiscarded OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of frames discarded due to receiving multiple copies." ::= { brzaccVLWirelessLinkCounters 8 } brzaccVLNoOfInternallyDiscardedMirCir OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of data frames received from the Ethernet port that were discarded by the MIR/CIR mechanism either to avoid exceeding the maximum allowed information rate, or when the wireless link conditions do not enable reaching the allowed rate." ::= { brzaccVLWirelessLinkCounters 9 } brzaccVLTotalRxConcatenatedFramesDouble OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The total number of double concatenated frames received from the wireless media, including duplicate frames." ::= { brzaccVLWirelessLinkCounters 10 } brzaccVLTotalRxConcatenatedFramesSingle OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The total number of data fast frames single concatenated frames received from the wireless media, including duplicate frames." ::= { brzaccVLWirelessLinkCounters 11 } brzaccVLTotalRxConcatenatedFramesMore OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The total number of data fast frames concatenated with more then two frames received from the wireless media, including duplicate frames." ::= { brzaccVLWirelessLinkCounters 12 } -- brzaccVLInternallyGeneratedFramesSubmittedToBridge OBJECT-TYPE -- SYNTAX Counter32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "Applicable to SU and AU. Read-only. -- The number of internally generated frames(wireless management and control frames) -- submitted to the bridge for transmission to the wireless media." -- ::= { brzaccVLWirelessLinkCounters 10 } brzaccVLTxEvents OBJECT IDENTIFIER ::= {brzaccVLWirelessLinkEvents 1} brzaccVLDroppedFrameEvents OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of frames that were dropped because they were retransmitted to the maximum allowed number of retransmissions without being acknowledged." ::= { brzaccVLTxEvents 1 } brzaccVLFramesDelayedDueToSwRetry OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Not applicable for units with SW Version 3.0 and higher. The number of frames that were delayed because the SW retry algorithm was activated on a previous frame designated for the same recipient." ::= { brzaccVLTxEvents 2 } brzaccVLUnderrunEvents OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of frames whose transmission was aborted because the rate of submitting frames for transmission exceeded the available transmission capability." ::= { brzaccVLTxEvents 3 } brzaccVLOthersTxEvents OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of Tx events due to problems other than those of the other Tx Events counters." ::= { brzaccVLTxEvents 4 } brzaccVLTotalTxEvents OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The total number of Tx special events." ::= { brzaccVLTxEvents 5 } brzaccVLRxEvents OBJECT IDENTIFIER ::= {brzaccVLWirelessLinkEvents 2} brzaccVLPhyErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units, only when DFS is enabled. The number of unidentified signals." ::= { brzaccVLRxEvents 1 } brzaccVLCRCErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of frames received from the wireless media containing CRC errors." ::= { brzaccVLRxEvents 2 } brzaccVLOverrunEvents OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of frames that were discarded because the receive rate exceeded the processing capability or the capacity of the Ethernet port." ::= { brzaccVLRxEvents 3 } brzaccVLRxDecryptEvents OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of frames that were not received properly due to a problem in the data decryption mechanism." ::= { brzaccVLRxEvents 4 } brzaccVLTotalRxEvents OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The total number of Rx special events." ::= { brzaccVLRxEvents 5 } -- Associations Database -- brzaccVLMacAddressDatabase OBJECT IDENTIFIER ::= {brzaccVLSiteSurvey 5} brzaccVLAUMacAddressDatabase OBJECT IDENTIFIER ::= {brzaccVLMacAddressDatabase 1} brzaccVLAUAdbResetAllModulationLevelCounters OBJECT-TYPE SYNTAX INTEGER { reset (1), cancel (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. To reset all the counters for all SUs/RB in the MAC Address Database." ::= { brzaccVLAUMacAddressDatabase 1 } brzaccVLAUAdbTable OBJECT-TYPE SYNTAX SEQUENCE OF BrzaccVLAUAdbEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to AU/BU only. AU/BU MAC Address Database table." ::= { brzaccVLAUMacAddressDatabase 2 } brzaccVLAUAdbEntry OBJECT-TYPE SYNTAX BrzaccVLAUAdbEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to AU/BU only. An entry in the AU/BU MAC Address Database table." INDEX { brzaccVLAdbIndex } ::= { brzaccVLAUAdbTable 1 } BrzaccVLAUAdbEntry ::= SEQUENCE { brzaccVLAdbIndex INTEGER, brzaccVLAdbMacAddress MacAddress, brzaccVLAdbStatus INTEGER, brzaccVLAdbSwVersion DisplayString, brzaccVLAdbSNR INTEGER, brzaccVLAdbMaxModulationLevel INTEGER, brzaccVLAdbTxFramesTotal Counter32, brzaccVLAdbDroppedFramesTotal Counter32, brzaccVLAdbTxSuccessModLevel1 Counter32, brzaccVLAdbTxSuccessModLevel2 Counter32, brzaccVLAdbTxSuccessModLevel3 Counter32, brzaccVLAdbTxSuccessModLevel4 Counter32, brzaccVLAdbTxSuccessModLevel5 Counter32, brzaccVLAdbTxSuccessModLevel6 Counter32, brzaccVLAdbTxSuccessModLevel7 Counter32, brzaccVLAdbTxSuccessModLevel8 Counter32, brzaccVLAdbTxFailedModLevel1 Counter32, brzaccVLAdbTxFailedModLevel2 Counter32, brzaccVLAdbTxFailedModLevel3 Counter32, brzaccVLAdbTxFailedModLevel4 Counter32, brzaccVLAdbTxFailedModLevel5 Counter32, brzaccVLAdbTxFailedModLevel6 Counter32, brzaccVLAdbTxFailedModLevel7 Counter32, brzaccVLAdbTxFailedModLevel8 Counter32, brzaccVLAdbCirTx INTEGER, brzaccVLAdbMirTx INTEGER, brzaccVLAdbCirRx INTEGER, brzaccVLAdbMirRx INTEGER, brzaccVLAdbCirMaxDelay INTEGER, brzaccVLAdbDistance INTEGER, brzaccVLAdbHwRevision INTEGER, brzaccVLAdbCpldVer DisplayString, brzaccVLAdbCountryCode INTEGER, brzaccVLAdbBootVer DisplayString, brzaccVLAdbAtpcOption INTEGER, brzaccVLAdbAdapModOption INTEGER, brzaccVLAdbBurstModeOption INTEGER, brzaccVLAdbConcatenationOption INTEGER, brzaccVLAdbSecurityMode INTEGER, brzaccVLAdbAuthOption INTEGER, brzaccVLAdbDataEncyptOption INTEGER, brzaccVLAdbAge INTEGER, brzaccVLAdbUnitName DisplayString } brzaccVLAdbIndex OBJECT-TYPE SYNTAX INTEGER (1..512) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The index of an entry in the AU/BU MAC Address Database table." ::= { brzaccVLAUAdbEntry 1 } brzaccVLAdbMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The MAC Address of an SU/RB entry in the MAC Address Database table." ::= { brzaccVLAUAdbEntry 2 } brzaccVLAdbStatus OBJECT-TYPE SYNTAX INTEGER { associated (1), authenticated (2), notAuthenticated (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The status of the relevant SU/RB." ::= { brzaccVLAUAdbEntry 3 } brzaccVLAdbSwVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The SW version of the relevant SU/RB." ::= { brzaccVLAUAdbEntry 4 } brzaccVLAdbSNR OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The average Signal to Noise Ratio in dB of frames received by the AU/BU from the relevant SU/RB." ::= { brzaccVLAUAdbEntry 5 } brzaccVLAdbMaxModulationLevel OBJECT-TYPE SYNTAX INTEGER { modLevel-1 (1), modLevel-2 (2), modLevel-3 (3), modLevel-4 (4), modLevel-5 (5), modLevel-6 (6), modLevel-7 (7), modLevel-8 (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The value configured in the relevant SU/RB for the Maximum Modulation Level parameter. Modulation Level 8 is not applicable for units with HW revision A." ::= { brzaccVLAUAdbEntry 6 } brzaccVLAdbTxFramesTotal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of unicast frames (excluding retransmissions) that were successfully transmitted to the SU/RB over the wireless link." ::= { brzaccVLAUAdbEntry 7 } brzaccVLAdbDroppedFramesTotal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of frames intended to the SU/RB that were dropped because they were retransmitted to the extent of the maximum allowed number of retransmissions without being acknowledged." ::= { brzaccVLAUAdbEntry 8 } brzaccVLAdbTxSuccessModLevel1 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of unicast frames (excluding retransmissions) that were successfully transmitted to the SU/RB over the wireless link using modulation level 1." ::= { brzaccVLAUAdbEntry 9 } brzaccVLAdbTxSuccessModLevel2 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of unicast frames (excluding retransmissions) that were successfully transmitted to the SU/RB over the wireless link using modulation level 2." ::= { brzaccVLAUAdbEntry 10 } brzaccVLAdbTxSuccessModLevel3 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of unicast frames (excluding retransmissions) that were successfully transmitted to the SU/BU over the wireless link using modulation level 3." ::= { brzaccVLAUAdbEntry 11 } brzaccVLAdbTxSuccessModLevel4 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of unicast frames (excluding retransmissions) that were successfully transmitted to the SU/RB over the wireless link using modulation level 4." ::= { brzaccVLAUAdbEntry 12 } brzaccVLAdbTxSuccessModLevel5 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of unicast frames (excluding retransmissions) that were successfully transmitted to the SU/RB over the wireless link using modulation level 5." ::= { brzaccVLAUAdbEntry 13 } brzaccVLAdbTxSuccessModLevel6 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of unicast frames (excluding retransmissions) that were successfully transmitted to the SU/BU over the wireless link using modulation level 6." ::= { brzaccVLAUAdbEntry 14 } brzaccVLAdbTxSuccessModLevel7 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of unicast frames (excluding retransmissions) that were successfully transmitted to the SU/RB over the wireless link using modulation level 7." ::= { brzaccVLAUAdbEntry 15 } brzaccVLAdbTxSuccessModLevel8 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of unicast frames (excluding retransmissions) that were successfully transmitted to the SU/RB over the wireless link using modulation level 8. Not applicable for units with HW revision A." ::= { brzaccVLAUAdbEntry 16 } brzaccVLAdbTxFailedModLevel1 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of failures to successfully transmit unicast frames intended to the SU/RB using modulation level 1." ::= { brzaccVLAUAdbEntry 17 } brzaccVLAdbTxFailedModLevel2 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of failures to successfully transmit unicast frames intended to the SU/RB using modulation level 2." ::= { brzaccVLAUAdbEntry 18 } brzaccVLAdbTxFailedModLevel3 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of failures to successfully transmit unicast frames intended to the SU/RB using modulation level 3." ::= { brzaccVLAUAdbEntry 19 } brzaccVLAdbTxFailedModLevel4 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of failures to successfully transmit unicast frames intended to the SU/RB using modulation level 4." ::= { brzaccVLAUAdbEntry 20 } brzaccVLAdbTxFailedModLevel5 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of failures to successfully transmit unicast frames intended to the SU/RB using modulation level 5." ::= { brzaccVLAUAdbEntry 21 } brzaccVLAdbTxFailedModLevel6 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of failures to successfully transmit unicast frames intended to the SU/RB using modulation level 6." ::= { brzaccVLAUAdbEntry 22 } brzaccVLAdbTxFailedModLevel7 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of failures to successfully transmit unicast frames intended to the SU/RB using modulation level 7." ::= { brzaccVLAUAdbEntry 23 } brzaccVLAdbTxFailedModLevel8 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of failures to successfully transmit unicast frames intended to the SU/RB using modulation level 8. Not applicable for units with HW revision A." ::= { brzaccVLAUAdbEntry 24 } brzaccVLAdbCirTx OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU Only. Not applicable to BreezeNET-B products. Read-only. The value configured in the relevant SU for the CIR: SU to AU parameter." ::= { brzaccVLAUAdbEntry 25 } brzaccVLAdbMirTx OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The value configured in the relevant SU/RB for the MIR: SU/RB to AU/BU parameter." ::= { brzaccVLAUAdbEntry 26 } brzaccVLAdbCirRx OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU Only. Not applicable to BreezeNET-B products. The value configured in the relevant SU for the CIR: AU to SU parameter." ::= { brzaccVLAUAdbEntry 27 } brzaccVLAdbMirRx OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The value configured in the relevant SU/RB for the MIR: AU/BU to SU/RB parameter." ::= { brzaccVLAUAdbEntry 28 } brzaccVLAdbCirMaxDelay OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU Only. Not applicable to BreezeNET-B products. The value configured in the relevant SU for the CIR Maximum Delay parameter." ::= { brzaccVLAUAdbEntry 29 } brzaccVLAdbDistance OBJECT-TYPE SYNTAX INTEGER {below-2-Km(1)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU Only. The distance between the SU/RB and the AU/BU (In Kilometers)." ::= { brzaccVLAUAdbEntry 30 } brzaccVLAdbHwRevision OBJECT-TYPE SYNTAX INTEGER {hwRevisionA(1), hwRevisionB(2), hwRevisionC(3), hwRevisionD(4), hwRevisionE(5), na(255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU Only. The SU/RB HW Revision." ::= { brzaccVLAUAdbEntry 31 } brzaccVLAdbCpldVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU Only. The SU/RB CPLD Version." ::= { brzaccVLAUAdbEntry 32 } brzaccVLAdbCountryCode OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU Only. The SU/RB supported country code." ::= { brzaccVLAUAdbEntry 33 } brzaccVLAdbBootVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU Only. The SU/RB Boot Version." ::= { brzaccVLAUAdbEntry 34 } brzaccVLAdbAtpcOption OBJECT-TYPE SYNTAX INTEGER {disable (1), enable (2), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU Only. The SU/RB ATPC option configuration." ::= { brzaccVLAUAdbEntry 35 } brzaccVLAdbAdapModOption OBJECT-TYPE SYNTAX INTEGER {disable (1), enable (2), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU Only. The SU/RB adaptive modulation option configuration." ::= { brzaccVLAUAdbEntry 36 } brzaccVLAdbBurstModeOption OBJECT-TYPE SYNTAX INTEGER {disable (1), enable (2), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU Only. The SU/RB burst mode option configuration." ::= { brzaccVLAUAdbEntry 37 } brzaccVLAdbConcatenationOption OBJECT-TYPE SYNTAX INTEGER {disable (1), enable (2), na(255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU Only. The SU/RB concatenation option configuration." ::= { brzaccVLAUAdbEntry 39 } brzaccVLAdbSecurityMode OBJECT-TYPE SYNTAX INTEGER {wep(1), aes(2), fips197(3), na(255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU Only. The SU/RB security mode configuration." ::= { brzaccVLAUAdbEntry 41 } brzaccVLAdbAuthOption OBJECT-TYPE SYNTAX INTEGER {openSystem (1), sharedKey (2), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU Only. The SU/RB authentication algorithm configuration." ::= { brzaccVLAUAdbEntry 42 } brzaccVLAdbDataEncyptOption OBJECT-TYPE SYNTAX INTEGER {disable (1), enable (2), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU Only. The SU/RB data encryption option configuration." ::= { brzaccVLAUAdbEntry 43 } brzaccVLAdbAge OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The time since any packet was received from the relevant SU/RB." ::= { brzaccVLAUAdbEntry 44 } brzaccVLAdbUnitName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The unit name of the relevant SU/RB." ::= { brzaccVLAUAdbEntry 45 } brzaccVLUpLinkQualityIndicator OBJECT IDENTIFIER ::= { brzaccVLSiteSurvey 6} brzaccVLMeasureUpLinkQualityIndicator OBJECT-TYPE SYNTAX INTEGER { start (1) , cancel (2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB. Starts calculation of LQI. The calculation will be for a period of 10 seconds." ::= { brzaccVLUpLinkQualityIndicator 1 } brzaccVLReadUpLinkQualityIndicator OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB. The results of the last LQI calculation. Range: 1 to 8." ::= { brzaccVLUpLinkQualityIndicator 2 } brzaccVLUpLinkQualityIndicatorStatus OBJECT-TYPE SYNTAX INTEGER {fullTest(1) , limitedTest(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB Only. Indicates the test conditions. fullTest means that there are no limitations on the range of available modulation levels, and that all modulation levels from 1 to 8 can be used. limitedTest indicates that the results may not indicate the true quality since the available range is limited - by HW (HW Revision A), or by the applicable parameters in the country code, or by the configurable Maximum Modulation Level parameter." ::= { brzaccVLUpLinkQualityIndicator 3 } -- AC pinpoint table end brzaccVLMacPinpoint OBJECT IDENTIFIER ::= {brzaccVLSiteSurvey 7} brzaccVLMacPinpointTable OBJECT-TYPE SYNTAX SEQUENCE OF BrzaccVLMacPinpointEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to AU/BU only. A table that contains information about wireless device used by a certain Ethernet station in order to connect to the wireless network" ::= { brzaccVLMacPinpoint 1 } brzaccVLMacPinpointEntry OBJECT-TYPE SYNTAX BrzaccVLMacPinpointEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to AU/BU only. An entry in the MAC Pinpoint Table. Each entry contains an Ethernet station MAC address and the MAC address of the wireless device used to connect it to the wireless network" INDEX { mptEthernetStationMACAddress } ::= { brzaccVLMacPinpointTable 1 } BrzaccVLMacPinpointEntry ::= SEQUENCE { mptEthernetStationMACAddress MacAddress, mptUnitMACAddress MacAddress } mptEthernetStationMACAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The MAC address of the Ethernet station. It is used as an index in the MAC Pinpoint Table." ::= { brzaccVLMacPinpointEntry 1 } mptUnitMACAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The MAC address of the wireless device used by the station with the MAC Address from the index in order to access the wireless network." ::= { brzaccVLMacPinpointEntry 2 } -- AC pinpoint table end -- GATEWAY TABLE BEGIN brzaccVLDrapGatewaysTable OBJECT-TYPE SYNTAX SEQUENCE OF BrzaccVLDrapGatewayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides information about Gateways supporting DRAP that are registered at the AU" ::= { brzaccVLSiteSurvey 8 } brzaccVLDrapGatewayEntry OBJECT-TYPE SYNTAX BrzaccVLDrapGatewayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A Drap Gateway Entry." INDEX { brzaccVLDrapGatewayIndex } ::= { brzaccVLDrapGatewaysTable 1 } BrzaccVLDrapGatewayEntry ::= SEQUENCE { brzaccVLDrapGatewayIndex INTEGER, brzaccVLDrapGatewayIP IpAddress, brzaccVLDrapGatewayType INTEGER, brzaccVLDrapGatewayNoOfActiveVoiceCalls INTEGER } brzaccVLDrapGatewayIndex OBJECT-TYPE SYNTAX INTEGER (1..512) MAX-ACCESS read-only STATUS current DESCRIPTION "Gateway Entry's Index" ::= { brzaccVLDrapGatewayEntry 1 } brzaccVLDrapGatewayIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address of the Gateway" ::= { brzaccVLDrapGatewayEntry 2 } brzaccVLDrapGatewayType OBJECT-TYPE SYNTAX INTEGER { vgDataVoice (4), vgData1Voice1 (5), vgData4Voice2 (6), vgDataVoice2(7), ngData4Wireless (11), vgUnknown(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Gateway type" ::= { brzaccVLDrapGatewayEntry 3 } brzaccVLDrapGatewayNoOfActiveVoiceCalls OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The current number of active voice calls handled by the Gateway" ::= { brzaccVLDrapGatewayEntry 4 } -- GATEWAY TABLE END -- **************************************************************************************** -- TRAP defenitions: -- **************************************************************************************** brzaccVLTraps OBJECT IDENTIFIER ::= { breezeAccessVLMib 14 } brzaccVLTrapSUMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. SU/RB MAC Address." ::= { brzaccVLTraps 1 } --brzaccVLTrapSNRQuality OBJECT-TYPE -- SYNTAX INTEGER -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "Applicable to SU only. -- SNR of received signal." -- ::= { brzaccVLTraps 2 } brzaccVLTrapText OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Textual string for future use." ::= { brzaccVLTraps 3 } brzaccVLTrapToggle OBJECT-TYPE SYNTAX INTEGER{ on (1), off (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. An On/Off toggle status." ::= { brzaccVLTraps 4 } brzaccVLTrapParameterChanged OBJECT-TYPE SYNTAX INTEGER{ cirOrMir (1), ipFilter (2), vlan (4)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. A modification to one of the parameters related to CIR/MIR, IP Filtering or VLAN." ::= { brzaccVLTraps 5 } brzaccVLTrapAccessRights OBJECT-TYPE SYNTAX INTEGER{ notLoggedIn (1), readOnly (2), installer (3), administrator (4), factory (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The access rights used for login." ::= { brzaccVLTraps 6 } brzaccVLTrapLog OBJECT-TYPE SYNTAX INTEGER{ telnetLogin (3), telnetLogout (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Login or logout to the Monitor program via Telnet." ::= { brzaccVLTraps 7 } brzaccVLTrapTelnetUserIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The IP address of a Telnet user." ::= { brzaccVLTraps 8 } brzaccVLTrapRTx OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Retransmissions as a percentage of total transmissions." ::= { brzaccVLTraps 9 } brzaccVLTrapFtpOrTftpStatus OBJECT-TYPE SYNTAX INTEGER{ successful (1), failed (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The status of the last FTP/TFTP loading procedure." ::= { brzaccVLTraps 10 } brzaccVLDFSMoveFreq OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU with HW revision B and lower (for units with HW revision C and higher replaced by brzaccVLTrapDFSMoveFreq New to support a resolution of 0.5 MHz). The new frequency in MHz after detecting radar on a previous channel." ::= { brzaccVLTraps 11 } brzaccVLDFSMoveFreqNew OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU. The new frequency in MHz after detecting radar on a previous channel. (Replaces brzaccVLDFSMoveFreq to support a resolution of 0.5 MHz for units with HW revision C and higher)." ::= { brzaccVLTraps 12 } brzaccVLEthBroadcastThresholdExceeded OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of packets that are dropped by the ethernet broadcast/multicast limiter." ::= { brzaccVLTraps 13 } brzaccVLTrapSubscriberType OBJECT-TYPE SYNTAX INTEGER{ unknownSubscriberType(0), su-3(3) , su-6(6) , rb-14(14), su-24(24), rb-28(28), su-54(54), rb-100(100) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AUS only. The type of subscriber that was rejected by AUS" ::= { brzaccVLTraps 14 } brzaccVLTrapMACAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to BU/RB only. The MAC address of the BNET B unit whose type has been changed" ::= { brzaccVLTraps 15 } brzaccVLNewUnitTypeTrap OBJECT-TYPE SYNTAX INTEGER { bu(1), rb(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to BU/RB only. The new type of the BNET B unit." ::= { brzaccVLTraps 16 } brzaccVLTrapSWVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The SW version of the SU that tries to associate with a station that has Wireless Link Prioritization Enabled" ::= { brzaccVLTraps 17 } -- -- Private Traps for BreezeAccessVL -- brzaccVLSUassociatedAUTRAP NOTIFICATION-TYPE OBJECTS { brzaccVLTrapSUMacAddr -- SU MAC address } STATUS current DESCRIPTION "An AU/BU trap indicating a new association with an SU/RB." ::= { brzAccessVLProducts 2 } brzaccVLAUdisassociatedTRAP NOTIFICATION-TYPE OBJECTS { brzaccVLTrapSUMacAddr --Unit MAC address } STATUS current DESCRIPTION "An AU/BU trap indicating that an SU/RB has been disassociated from the AU. The AU/BU decides that an SU/RB has been disassociated from it and remove it from the ADB after receiving from another AU/BU a SNAP frame with the SU/RB MAC address. The SNAP frame indicating a network topology change where the SU/RB has associated with another AU/BU will be received if both AUs/BUs are connected to the same Ethernet backbone." ::= { brzAccessVLProducts 3 } brzaccVLAUagingTRAP NOTIFICATION-TYPE OBJECTS { brzaccVLTrapSUMacAddr -- Unit MAC address } STATUS current DESCRIPTION "An AU/BU trap indicating that the unit association was aged out and removed from the Association database following its failure to acknowledge a specified number of consecutive frames." ::= { brzAccessVLProducts 4 } brzaccVLSUassociatedTRAP NOTIFICATION-TYPE OBJECTS { -- brzaccVLLastAUMacAddress, Old AU mac address brzaccVLAssociatedAU -- New AU mac address -- brzaccVLTrapLastSNRQuality, Average SNR with old AU } STATUS current DESCRIPTION "An SU/RB trap indicating association with an AU/BU. In addition to the MAC address information of the AU/BU, the trap also includes information on the average SNR of frames received from the AU/BU." ::= { brzAccessVLProducts 6 } brzaccVLAUwirelessQualityTRAP NOTIFICATION-TYPE OBJECTS { brzaccVLTrapToggle, brzaccVLTrapRTx } STATUS current DESCRIPTION "An AU/BU trap, indicating that the quality of the wireless link (retransmissions rate) has changed and dropped below (Off) or increased above (On) a threshold , defined by the *brzaccVLWirelessTrapThreshold. The threshold for AU/BU is a percentage of retransmissions." ::= { brzAccessVLProducts 20 } brzaccVLPowerUpFromReset NOTIFICATION-TYPE OBJECTS { brzaccVLUnitMacAddress -- Unit MAC address } STATUS current DESCRIPTION "An AU/BU trap indicating power up after Reset." ::= { brzAccessVLProducts 101 } brzaccVLTelnetStatusTRAP NOTIFICATION-TYPE OBJECTS { brzaccVLTrapLog, brzaccVLTrapAccessRights, brzaccVLTrapTelnetUserIpAddress } STATUS current DESCRIPTION "Applicable to all units. A trap indicating that a log-in or log-out has been performed via Telnet. Includes the log-in access right and the IP address of the PC performing Telnet." ::= { brzAccessVLProducts 102 } brzaccVLParameterChangedTRAP NOTIFICATION-TYPE OBJECTS { brzaccVLTrapParameterChanged } STATUS current DESCRIPTION "Applicable to all units. A trap indicating a change in a CIR/MIR, IP Filter or VLAN parameter." ::= { brzAccessVLProducts 103 } brzaccVLLoadingStatusTRAP NOTIFICATION-TYPE OBJECTS { brzaccVLTrapFtpOrTftpStatus, brzaccVLUnitMacAddress } STATUS current DESCRIPTION "Applicable to all units. A trap indicating that last FTP/TFTP loading process has been finished successfully or failed. " ::= { brzAccessVLProducts 104 } brzaccVLPromiscuousModeTRAP NOTIFICATION-TYPE OBJECTS { brzaccVLTrapToggle, brzaccVLUnitMacAddress } STATUS current DESCRIPTION "An AU/BU trap, indicating that the AU/BU In (On) Promiscuous Mode or out (Off) Promiscuous Mode." ::= { brzAccessVLProducts 105 } brzaccVLDFSRadarDetecetedTRAP NOTIFICATION-TYPE STATUS current DESCRIPTION "DFS: Applicable to AU/BU only. A trap indicating that a radar was detected. " ::= { brzAccessVLProducts 106 } brzaccVLDFSFrequcnyTRAP NOTIFICATION-TYPE OBJECTS { brzaccVLDFSMoveFreq, brzaccVLDFSMoveFreqNew } STATUS current DESCRIPTION "Applicable to AU/BU only. A trap indicating that the unit moved to a new frequency. " ::= { brzAccessVLProducts 107 } brzaccVLDFSNoFreeChannelsExistsTRAP NOTIFICATION-TYPE STATUS current DESCRIPTION "Applicable to AU/BU only. A trap indicating that a radar was detected and there is no free channel. " ::= { brzAccessVLProducts 108 } brzaccVLEthBroadcastMulticatLimiterTRAP NOTIFICATION-TYPE OBJECTS { brzaccVLEthBroadcastThresholdExceeded } STATUS current DESCRIPTION "Applicable to all units. The trap is send if the ethernet broadcast filter threshold is exceeded and it contains the number of dropped packets." ::= { brzAccessVLProducts 109 } brzaccVLAUSUnsupportedSubscriberTypeTRAP NOTIFICATION-TYPE OBJECTS { brzaccVLTrapSUMacAddr, brzaccVLTrapSubscriberType } STATUS current DESCRIPTION "Applicable to AUS only. This trap is generated when a subscriber with unsupported type tries to associate to AUS. The AUS supports only SU-3 and SU-6. The first variable of the trap is the subscriber MAC Address. The second variable is the type of subscriber" ::= { brzAccessVLProducts 110 } brzaccVLUnitTypeChangedTRAP NOTIFICATION-TYPE OBJECTS { brzaccVLTrapMACAddress, brzaccVLNewUnitTypeTrap } STATUS current DESCRIPTION "Applicable to BU/RB only. This trap is generated when the user change the type of the BreezeNET B unit. The RB can be converted in BU or vice versa. The first variable of the trap is the unit MAC Address. The second variable is the new type of the unit" ::= { brzAccessVLProducts 111 } brzaccVLWLPrioritizationNotSupportedBySUTRAP NOTIFICATION-TYPE OBJECTS { brzaccVLTrapSUMacAddr, brzaccVLTrapSWVersion } STATUS current DESCRIPTION "Applicable to AU/BU only. This trap is generated when an SU/RB with a SW version below 4.0 that does not support Wireless Link Prioritization is associated with an AU/BU with thw Wireless Link Prioritization Option enabled. The first variable of the trap is the SU/RB MAC Address. The second variable is the SW version of the SU/RB" ::= { brzAccessVLProducts 112 } END