-- Title: BWA Private MIB -- This Private MIB supports BWA-PtMP and BWA-PtP product lines. -- -- -- Version: 4.5.16 -- Date: Tuesday August 14 2007 -- Comments: BWA agents also support the following Public MIBs: -- This MIB supports BWA VL products (AU and SU), -- BWA 4900 (AU and SU) and -- BWA-PtP products (BU and RB). -- Some MIB compilers require that the following lines -- for proper compilation --#include "rfc1155.smi" --#include "rfc1212.smi" -- mgmt OBJECT IDENTIFIER ::= { iso org(3) dod(6) internet(1) mgmt(2) } -- mib OBJECT IDENTIFIER ::= { mgmt 1 } -- directory OBJECT IDENTIFIER ::= { internet 1 } -- experimental OBJECT IDENTIFIER ::= { internet 3 } -- private OBJECT IDENTIFIER ::= { internet 4 } -- enterprises OBJECT IDENTIFIER ::= { private 1 } -- End of lines which might be needed to other MIB browsers -- for proper compilation BWA-DOT11-WLAN-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, NOTIFICATION-TYPE, enterprises, IpAddress,Counter32,OBJECT-TYPE FROM SNMPv2-SMI; bwa OBJECT IDENTIFIER ::= { enterprises 12394 } products OBJECT IDENTIFIER ::= { bwa 1 } bwaVLMib MODULE-IDENTITY LAST-UPDATED "0708141146Z" ORGANIZATION "BWA Products" CONTACT-INFO "Contact Man Postal: BWA Products Street Number ZipCode Country Tel: 000-0-0000000 Fax: 000-0-0000000 E-mail: E-mail" DESCRIPTION "BWA VL products, BWA 4900, BWA-PtP" REVISION "0708141146Z" DESCRIPTION "Version 4.5" ::= { products 1 } MacAddress ::= OCTET STRING (SIZE(6)) DisplayString ::= OCTET STRING bwaOID OBJECT IDENTIFIER ::= { bwa 4 } bwaVLOID OBJECT IDENTIFIER ::= { bwaOID 1 } bwaVLAU OBJECT IDENTIFIER ::= { bwaVLOID 1 } bwaVLSU OBJECT IDENTIFIER ::= { bwaVLOID 2 } bwaVLAU-BS OBJECT IDENTIFIER ::= { bwaVLOID 4 } bwaVLAU-SA OBJECT IDENTIFIER ::= { bwaVLOID 5 } bwaVLAUS-BS OBJECT IDENTIFIER ::= { bwaVLOID 6 } bwaVLAUS-SA OBJECT IDENTIFIER ::= { bwaVLOID 7 } bwaVLAU-EZ OBJECT IDENTIFIER ::= { bwaVLOID 8 } bwaVLSU-6-1D OBJECT IDENTIFIER ::= { bwaVLOID 11 } bwaVLSU-6-BD OBJECT IDENTIFIER ::= { bwaVLOID 12 } bwaVLSU-24-BD OBJECT IDENTIFIER ::= { bwaVLOID 13 } bwaVLSU-BD OBJECT IDENTIFIER ::= { bwaVLOID 14 } bwaVLSU-54-BD OBJECT IDENTIFIER ::= { bwaVLOID 15 } bwaVLSU-3-1D OBJECT IDENTIFIER ::= { bwaVLOID 16 } bwaVLSU-3-4D OBJECT IDENTIFIER ::= { bwaVLOID 17 } bwaVLSU-I OBJECT IDENTIFIER ::= { bwaVLOID 18 } ptp-BU-B14 OBJECT IDENTIFIER ::= { bwaVLOID 21 } ptp-BU-B28 OBJECT IDENTIFIER ::= { bwaVLOID 22 } ptp-BU-B100 OBJECT IDENTIFIER ::= { bwaVLOID 23 } ptp-RB-B14 OBJECT IDENTIFIER ::= { bwaVLOID 31 } ptp-RB-B28 OBJECT IDENTIFIER ::= { bwaVLOID 32 } ptp-RB-B100 OBJECT IDENTIFIER ::= { bwaVLOID 33 } bwa4900-AU-BS OBJECT IDENTIFIER ::= { bwaVLOID 41 } bwa4900-AU-SA OBJECT IDENTIFIER ::= { bwaVLOID 42 } bwa4900-SU-BD OBJECT IDENTIFIER ::= { bwaVLOID 51 } bwaVLProducts OBJECT IDENTIFIER ::= { bwaVLOID 3 } -- **************************************************************************************** -- **************************************************************************************** -- General System Info -- =================== bwaVLSysInfo OBJECT IDENTIFIER ::= {bwaVLMib 1} bwaVLUnitHwVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Hardware platform version." ::= { bwaVLSysInfo 1 } bwaVLRunningSoftwareVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Running software version." ::= { bwaVLSysInfo 2 } bwaVLRunningFrom OBJECT-TYPE SYNTAX INTEGER { mainVersion(1) , shadowVersion(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The memory (main or shadow) from which the current version is running from." ::= { bwaVLSysInfo 3 } bwaVLMainVersionNumber OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Main software version number." ::= { bwaVLSysInfo 4 } bwaVLMainVersionFileName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Main software version file name." ::= { bwaVLSysInfo 5 } bwaVLShadowVersionNumber OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Shadow software version number." ::= { bwaVLSysInfo 6 } bwaVLShadowVersionFileName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Shadow software version file name." ::= { bwaVLSysInfo 7 } bwaVLUnitMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Unit hardware MAC address." ::= { bwaVLSysInfo 8 } bwaVLUnitType OBJECT-TYPE SYNTAX INTEGER {auBS (1), auSA(2) , su-6-1D(3),su-6-BD(4),su-24-BD(5), bu-B14(6),bu-B28(7),rb-B14(8),rb-B28(9),su-BD(10),su-54-BD (11), su-3-1D(12),su-3-4D(13),ausBS(14),ausSA(15), auBS4900(16),auSA4900(17),su4900(18), bu-B100(19), rb-B100(20), su-I(21), au-E(22) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. auBS (1) : AU-BS (modular access unit). auSA (2) : AU-SA (stand-alone access unit). su-6-1D (3) : SU-6-1D (subscriber unit supporting 6 Mbps) su-6-BD (4) : SU-6-BD (subscriber unit supporting 6 Mbps). su-24-BD (5) : SU-24-BD (subscriber unit supporting 24 Mbps). bu-B14 (6) : BU-B14 (PtP Base Unit supporting 14 Mbps). bu-B28 (7) : BU-B28 (PtP Base Unit supporting 28 Mbps). rb-B14 (8) : RB-B14 (PtP Remote Bridge supporting 14 Mbps). rb-B28 (9) : RB-B28 (PtP Remote Bridge supporting 28 Mbps). su-BD (10) : SU-BD (subscriber unit). su-54-BD(11) : SU-54-BD (subscriber unit supporting 54 Mbps). su-3-1D (12) : SU-3-1D (subscriber unit supporting 3 Mbps). su-3-4D (13) : SU-3-4D (subscriber unit supporting 3 Mbps). ausBS (14) : AUS-BS (modular access unit supporting maxim 8 or 25 (via licensing) subscribers and allowing association only with SU-3 or SU-6). ausSA (15) : AUS-SA (stand-alone access unit supporting maxim 8 or 25 (via licensing)subscribers and allowing association only with SU-3 or SU-6 ). auBS4900(16) : AU-BS-4900 (BWA 4900 modular access unit) auSA4900(17) : AU-SA-4900 (BWA 4900 stand alone access unit) suBD4900(18) : SU-BD-4900 (BWA 4900 subscriber unit) bu-B100 (19) : BU-B100 (PtP Base Unit unlimited throughput) rb-B100 (20) : BU-B100 (PtP Remote Bridge unlimited throughput) su-I (21) : SU-I au-E (22) : AU-E" ::= { bwaVLSysInfo 9 } bwaVLAssociatedAU OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. Associated AU/BU MAC address." ::= { bwaVLSysInfo 10 } bwaVLNumOfAssociationsSinceLastReset OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of associations since last reset, including duplicate associations (re-associations)." ::= { bwaVLSysInfo 11 } bwaVLCurrentNumOfAssociations OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BWA-PtP products. The number of SUs currently associated with the AU. BWA-PtP products return 65535." ::= { bwaVLSysInfo 13 } bwaVLUnitBootVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Boot version." ::= { bwaVLSysInfo 14 } bwaVLRadioBand OBJECT-TYPE SYNTAX INTEGER {band-5-8GHz (1), band-5-4GHz (2) , band-4-9GHz (3),band-5-2GHz (4),band-2-4GHz (5),band-5-3GHz (6),band-4-9GHzJapan (7)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The unit's radio band." ::= { bwaVLSysInfo 15 } bwaVLCurrentEthernetPortState OBJECT-TYPE SYNTAX INTEGER { halfDuplexAnd10Mbps (1), fullDuplexAnd10Mbps (2), halfDuplexAnd100Mbps (3), fullDuplexAnd100Mbps (4), linkDown (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The current Ethernet port state." ::= { bwaVLSysInfo 16 } bwaVLTimeSinceLastReset OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The elapsed time since last reset." ::= { bwaVLSysInfo 17 } bwaVLCountryDependentParameters OBJECT IDENTIFIER ::= {bwaVLSysInfo 18} bwaVLCountryCode OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The country code and country name or country group name that is supported by the unit." ::= { bwaVLCountryDependentParameters 1 } bwaVLCountryDependentParamsTable OBJECT-TYPE SYNTAX SEQUENCE OF BwaVLCountryDependentParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. A table of country dependent parameters." ::= {bwaVLCountryDependentParameters 2} bwaVLCountryDependentParameterEntry OBJECT-TYPE SYNTAX BwaVLCountryDependentParameterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. An entry in the Country Dependent Parameters table." INDEX { bwaVLCountryDependentParameterTableIdx } ::= { bwaVLCountryDependentParamsTable 1 } BwaVLCountryDependentParameterEntry ::= SEQUENCE { bwaVLCountryDependentParameterTableIdx INTEGER, bwaVLCountryDependentParameterFrequencies DisplayString, bwaVLAllowedBandwidth INTEGER, bwaVLRegulationMaxTxPowerAtAntennaPort INTEGER, bwaVLRegulationMaxEIRP INTEGER, bwaVLMinModulationLevel INTEGER, bwaVLMaxModulationLevel INTEGER, bwaVLBurstModeSupport INTEGER, bwaVLMaximumBurstDuration INTEGER, bwaVLDfsSupport INTEGER, bwaVLMinimumHwRevision INTEGER } bwaVLCountryDependentParameterTableIdx OBJECT-TYPE SYNTAX INTEGER (1..5) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The sub-band ID of the entry in the Country Dependent Parameters table. Serves also as index for the table entry." ::= { bwaVLCountryDependentParameterEntry 1 } bwaVLCountryDependentParameterFrequencies OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The frequencies included in the applicable sub-band entry." ::= { bwaVLCountryDependentParameterEntry 2 } bwaVLAllowedBandwidth OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The bandwidth when using the applicable the sub-band." ::= { bwaVLCountryDependentParameterEntry 3 } bwaVLRegulationMaxTxPowerAtAntennaPort OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The maximum allowed Tx power when using the applicable sub-band. A RegulationMaxTxPowerAtAntennaPort of 255, means no limit" ::= { bwaVLCountryDependentParameterEntry 4 } bwaVLRegulationMaxEIRP OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The maximum Tx EIRP when using the applicable sub-band. A Regulation Max EIRP of 0, means no limit." ::= { bwaVLCountryDependentParameterEntry 5 } bwaVLMinModulationLevel OBJECT-TYPE SYNTAX INTEGER { level1 (1), level2 (2), level3 (3), level4 (4), level5 (5), level6 (6), level7 (7), level8 (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The minimum supported modulation level." ::= { bwaVLCountryDependentParameterEntry 6 } bwaVLMaxModulationLevel OBJECT-TYPE SYNTAX INTEGER { level1 (1), level2 (2), level3 (3), level4 (4), level5 (5), level6 (6), level7 (7), level8 (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The maximum supported modulation level." ::= { bwaVLCountryDependentParameterEntry 7 } bwaVLBurstModeSupport OBJECT-TYPE SYNTAX INTEGER {supported(1), notSupported(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The supported Burst Mode Option." ::= { bwaVLCountryDependentParameterEntry 8} bwaVLMaximumBurstDuration OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Applicable only if Burst Mode Option is supported. The maximum supported burst duration." ::= { bwaVLCountryDependentParameterEntry 9} bwaVLDfsSupport OBJECT-TYPE SYNTAX INTEGER {supported(1), notSupported(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The supported Dfs Option." ::= { bwaVLCountryDependentParameterEntry 10} bwaVLMinimumHwRevision OBJECT-TYPE SYNTAX INTEGER {hwRevisionA (1), hwRevisionB (2), hwRevisionC (3), hwRevisionD (4), hwRevisionE (5), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The Minimum HW Revision needed to support the country code." ::= { bwaVLCountryDependentParameterEntry 11} bwaVLAuthenticationEncryptionSupport OBJECT-TYPE SYNTAX INTEGER {supported(1), notSupported(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The supported Authentication Encryption Option." ::= { bwaVLCountryDependentParameters 3 } bwaVLDataEncryptionSupport OBJECT-TYPE SYNTAX INTEGER {supported(1), notSupported(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The supported Data Encryption Option." ::= { bwaVLCountryDependentParameters 4 } bwaVLAESEncryptionSupport OBJECT-TYPE SYNTAX INTEGER {supported(1), notSupported(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The supported AES Encryption Option." ::= { bwaVLCountryDependentParameters 5 } bwaVLAntennaGainChange OBJECT-TYPE SYNTAX INTEGER {supported(1), notSupported(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Indicates whether the Antenna Gain parameter is changeable or fixed." ::= { bwaVLSysInfo 19 } bwaVLAteTestResults OBJECT-TYPE SYNTAX INTEGER { none(0), pass(1), fail(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Results of ATE Test " ::= { bwaVLSysInfo 20 } bwaVLSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE(0..35)) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Serial Number of the unit" ::= { bwaVLSysInfo 21 } -- Unit Control -- ============ bwaVLUnitControl OBJECT IDENTIFIER ::= {bwaVLMib 2} bwaVLResetUnit OBJECT-TYPE SYNTAX INTEGER { cancel (1), resetSystemNow (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Resets the unit and applies new parameter values." ::= { bwaVLUnitControl 1 } bwaVLSetDefaults OBJECT-TYPE SYNTAX INTEGER { noDefaultSettingRequested (0), completeFactory (1), partialFactory (2), completeOperator (3), partialOperator (4), cancelCurrentPendingRequest(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Sets unit configuration to Defaults values after the next reset. noDefaultSettingRequested : Read-Only Option, no Default setting was Issued. completeFactory : All parameters revert to Factory Defaults values. partialFactory : All parameters revert to Factory Defaults values, except the parameters required for maintaining wireless connectivity. completeOperator: All parameters revert to Operator Defaults values. partialOperator : All parameters revert to Operator Defaults values, except the parameters required for maintaining wireless connectivity. cancelCurrentPendingRequest : Default Setting request is cancelled." ::= { bwaVLUnitControl 2 } bwaVLUnitName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The unit name. A string of up to 32 printable ASCII characters." ::= { bwaVLUnitControl 3 } bwaVLFlashMemoryControl OBJECT-TYPE SYNTAX INTEGER { resetAndBootFromShadowVersion (1), useRunningVersionAfterReset (2),cancel(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. resetAndBootFromShadowVersion : Activates the backup version. useRunningVersionAfterReset : The currently active version will become the main version and will be activated after next reset." ::= { bwaVLUnitControl 4 } bwaVLTelnetLogoutTimer OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Time-out of management via Telnet program. Automatic exit if the program is inactive for the defined time. Range: 1 to 999 (minutes)." ::= { bwaVLUnitControl 5 } bwaVLSaveCurrentConfigurationAsOperatorDefaults OBJECT-TYPE SYNTAX INTEGER { saveAsDefaults (1),cancel(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Saves the current configuration as Operator Defaults. Cannot be executed after requesting set defaults and the unit was not reset." ::= { bwaVLUnitControl 6 } bwaVLExitTelnet OBJECT-TYPE SYNTAX INTEGER { cancelOperation (1), exit (2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Exit the management via Telnet program." ::= { bwaVLUnitControl 7 } bwaVLUnitPasswords OBJECT IDENTIFIER ::= {bwaVLUnitControl 8} bwaVLReadOnlyPassword OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The User (read only) password. This is also the Read Community String. Up to 8 printable ASCII characters." ::= { bwaVLUnitPasswords 1 } bwaVLInstallerPassword OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The Installer password. Up to 8 printable ASCII characters." ::= { bwaVLUnitPasswords 2 } bwaVLAdminPassword OBJECT-TYPE SYNTAX DisplayString (SIZE(1..8)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The Administrator password. Accessible only with SNMP Write Community String (administrator password). Up to 8 printable ASCII characters." ::= { bwaVLUnitPasswords 3 } bwaVLEthernetNegotiationMode OBJECT-TYPE SYNTAX INTEGER { force10MbpsAndHalfDuplex (1), force10MbpsAndFullDuplex (2), force100MbpsAndHalfDuplex (3), force100MbpsAndFullDuplex (4), autoNegotiationMode (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The speed/duplex mode of the Ethernet port." ::= { bwaVLUnitControl 9 } bwaVLFTPParameters OBJECT IDENTIFIER ::= {bwaVLUnitControl 10} bwaVLFTPServerParams OBJECT IDENTIFIER ::= {bwaVLFTPParameters 1} bwaVLFTPServerUserName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..18)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The user name to be used for access to the FTP server. Accessible only with SNMP Write Community String (administrator password)." ::= { bwaVLFTPServerParams 1 } bwaVLFTPServerPassword OBJECT-TYPE SYNTAX DisplayString (SIZE(0..18)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The password to be used for access to the FTP server. Accessible only with SNMP Write Community String (administrator password)." ::= { bwaVLFTPServerParams 2 } bwaVLFTPClientIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. For SW version higher than 4.0 this is read-only. The IP address of the FTP stack in the unit." ::= { bwaVLFTPServerParams 3 } bwaVLFTPServerIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The IP address of the FTP server." ::= { bwaVLFTPServerParams 4 } bwaVLFTPClientMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The Mask of the FTP stack in the unit." ::= { bwaVLFTPServerParams 5 } bwaVLFTPGatewayIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The FTP Gateway address" ::= { bwaVLFTPServerParams 6 } bwaVLFTPSwDownload OBJECT IDENTIFIER ::= {bwaVLFTPParameters 2} bwaVLFTPSwFileName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The name of the SW file to be downloaded." ::= { bwaVLFTPSwDownload 1 } bwaVLFTPSwSourceDir OBJECT-TYPE SYNTAX DisplayString (SIZE(0..80)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The source directory of the required file in the FTP server. Up to 80 printable ASCII characters. Use dot (.) To clear field" ::= { bwaVLFTPSwDownload 2 } bwaVLFTPDownloadSwFile OBJECT-TYPE SYNTAX INTEGER { downloadFile (1) , cancel (2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Execution of the SW download operation" ::= { bwaVLFTPSwDownload 3 } bwaVLConfigurationFileLoading OBJECT IDENTIFIER ::= {bwaVLFTPParameters 3} bwaVLConfigurationFileName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The name of the configuration file to be downloaded/uploaded." ::= { bwaVLConfigurationFileLoading 1 } bwaVLOperatorDefaultsFileName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The name of the Operator Defaults file to be downloaded/uploaded" ::= { bwaVLConfigurationFileLoading 2 } bwaVLFTPConfigurationFileSourceDir OBJECT-TYPE SYNTAX DisplayString (SIZE(0..80)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The source directory of the required file in the FTP server. Up to 80 printable ASCII characters. Use dot (.) To clear field" ::= { bwaVLConfigurationFileLoading 3 } bwaVLExecuteFTPConfigurationFileLoading OBJECT-TYPE SYNTAX INTEGER {executeFTPGetConfigurationFile (1), executeFTPPutConfigurationFile (2), executeFTPGetOperatorDefaults (3) , executeFTPPutOperatorDefaults (4), cancel (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Execution of the file download/upload operation." ::= { bwaVLConfigurationFileLoading 4 } bwaVLEventLogFileUploading OBJECT IDENTIFIER ::= {bwaVLFTPParameters 4} bwaVLEventLogFileName OBJECT-TYPE SYNTAX DisplayString (SIZE(1..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The name of the Event Log file to be uploaded." ::= { bwaVLEventLogFileUploading 1 } bwaVLEventLogDestinationDir OBJECT-TYPE SYNTAX DisplayString (SIZE(0..80)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The destination directory of the event log file. Up to 80 printable ASCII characters. Use dot (.) To clear field." ::= { bwaVLEventLogFileUploading 2 } bwaVLUploadEventLogFile OBJECT-TYPE SYNTAX INTEGER { uploadFile (1) , cancel (2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Execution of the event log upload operation." ::= { bwaVLEventLogFileUploading 3 } bwaVLLoadingStatus OBJECT-TYPE SYNTAX INTEGER {inProcess (1), successful (2), failed (3)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The status of the last loading operation." ::= { bwaVLUnitControl 11 } bwaVLEventLogFileParams OBJECT IDENTIFIER ::= {bwaVLUnitControl 12} bwaVLEventLogPolicy OBJECT-TYPE SYNTAX INTEGER {message (1), warning (2), error (3),fatal(4), logNone(5)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The lowest level event to be registered in the event log." ::= { bwaVLEventLogFileParams 1 } bwaVLEraseEventLog OBJECT-TYPE SYNTAX INTEGER { eraseEventLog (1),cancel(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Erase the event log." ::= { bwaVLEventLogFileParams 2 } bwaVLSystemLocation OBJECT-TYPE SYNTAX DisplayString (SIZE(0..34)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The unit location." ::= { bwaVLUnitControl 13 } bwaVLFeatureUpgrade OBJECT IDENTIFIER ::= {bwaVLUnitControl 14} bwaVLFeatureUpgradeManually OBJECT-TYPE SYNTAX DisplayString (SIZE(32..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Upgrade unit to support new feature. Enter your license number (32 to 64 hex digits)." ::= { bwaVLFeatureUpgrade 1 } bwaVLChangeUnitType OBJECT-TYPE SYNTAX INTEGER { bu(1), rb(2), cancel(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable RB/BU only. Change the unit type between BU and RB." ::= { bwaVLUnitControl 15 } bwaLighteAPWorkingMode OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. Change unit running mode: 0 - VL mode 1 - Mixed cell mode" ::= { bwaVLUnitControl 16 } -- Network Management Params -- ========================= bwaVLNwMngParameters OBJECT IDENTIFIER ::= {bwaVLMib 3} bwaVLAccessToNwMng OBJECT-TYPE SYNTAX INTEGER { fromWirelessOnly (1), fromEthernetOnly (2), fromBothWirelessAndEthernet (3), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The port to be used for remote management." ::= { bwaVLNwMngParameters 1 } bwaVLNwMngFilter OBJECT-TYPE SYNTAX INTEGER { disable (1), activateOnEthernetPort (2), activateOnWirelessPort (3), activateOnBothWirelessAndEthernet (4), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Disables or enable on one of the ports, or on both ports, IP address based filtering of management messages (e.g. SNMP , Telnet , TFTP , DHCP)." ::= { bwaVLNwMngParameters 2 } mngIpFilterTable OBJECT-TYPE SYNTAX SEQUENCE OF MngIpFilterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. A Management IP Filter Table of up to 3 IP addresses of devices that are authorized to access the unit for management purposes." ::= { bwaVLNwMngParameters 3 } mngIpFilterEntry OBJECT-TYPE SYNTAX MngIpFilterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. A Management IP Filter Table entry." INDEX { bwaVLNwMngIpTableIdx } ::= { mngIpFilterTable 1 } MngIpFilterEntry ::= SEQUENCE { bwaVLNwMngIpAddress IpAddress, bwaVLNwMngIpTableIdx INTEGER } bwaVLNwMngIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. An IP address in the Management IP Filter Table." ::= { mngIpFilterEntry 1 } bwaVLNwMngIpTableIdx OBJECT-TYPE SYNTAX INTEGER (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. A table index for an entry in the Management IP Filter Table." ::= { mngIpFilterEntry 2 } bwaVLDeleteOneNwIpAddr OBJECT-TYPE SYNTAX INTEGER (0 | 1..10 | 255) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. 0 - cancel operation. 1..10 - Deletes a single selected entry from the Management IP Filter Table." ::= { bwaVLNwMngParameters 4 } bwaVLDeleteAllNwIpAddrs OBJECT-TYPE SYNTAX INTEGER { deleteAll (1), cancelOperation (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Deletes all entries from the Management IP Filter Table." ::= { bwaVLNwMngParameters 5 } bwaVLAccessToNwTrap OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Enables or disables sending of traps." ::= { bwaVLNwMngParameters 6 } mngTrapTable OBJECT-TYPE SYNTAX SEQUENCE OF MngTrapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. A Management Trap Table of up to 10 IP addresses of stations to send traps to." ::= { bwaVLNwMngParameters 7 } mngTrapEntry OBJECT-TYPE SYNTAX MngTrapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. A Management Trap Table entry." INDEX { bwaVLNwTrapTableIdx } ::= { mngTrapTable 1 } MngTrapEntry ::= SEQUENCE { bwaVLNwMngTrapCommunity DisplayString, bwaVLNwMngTrapAddress IpAddress, bwaVLNwTrapTableIdx INTEGER } bwaVLNwMngTrapCommunity OBJECT-TYPE SYNTAX DisplayString (SIZE(0..14)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The trap community associated with the applicable entry in the Management Trap Table. Up to 14 printable case sensitive ASCII characters." ::= { mngTrapEntry 1 } bwaVLNwMngTrapAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. An IP address in the Management Trap Table entry." ::= { mngTrapEntry 2 } bwaVLNwTrapTableIdx OBJECT-TYPE SYNTAX INTEGER (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Tables Index for an entry in the Management Trap Table." ::= { mngTrapEntry 3 } bwaVLDeleteOneTrapAddr OBJECT-TYPE SYNTAX INTEGER (0 | 1..10 | 255) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. 0 - cancel operation. 1..10 - Deletes a single selected entry from the Management Trap Table." ::= { bwaVLNwMngParameters 8 } bwaVLDeleteAllTrapAddrs OBJECT-TYPE SYNTAX INTEGER { deleteAll (1),cancelOperation (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Deletes all entries from the Management Trap Table." ::= { bwaVLNwMngParameters 9 } bwaVLMngIpRangesTable OBJECT-TYPE SYNTAX SEQUENCE OF BwaVLMngIpRangeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. Table of Management IP Address Ranges" ::= { bwaVLNwMngParameters 10 } bwaVLMngIpRangeEntry OBJECT-TYPE SYNTAX BwaVLMngIpRangeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. A Management IP Address Ranges Table entry" INDEX { bwaVLMngIpRangeIdx } ::= { bwaVLMngIpRangesTable 1 } BwaVLMngIpRangeEntry ::= SEQUENCE { bwaVLMngIpRangeIdx INTEGER, bwaVLMngIpRangeFlag INTEGER, bwaVLMngIpRangeStart IpAddress, bwaVLMngIpRangeEnd IpAddress, bwaVLMngIpRangeMask IpAddress } bwaVLMngIpRangeIdx OBJECT-TYPE SYNTAX INTEGER (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Index of an entry in the Management IP Address Ranges Table" ::= { bwaVLMngIpRangeEntry 1 } bwaVLMngIpRangeFlag OBJECT-TYPE SYNTAX INTEGER { rangeDefinedByStartEndAddr(1), rangeDefinedByStartAddrMask(2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Defines the method of defining the range: Using Start & End Address( rangeDefinedByStartEndAddr ), or using Start Address and Mask ( rangeDefinedByStartAddrSubNetMask )." ::= { bwaVLMngIpRangeEntry 2 } bwaVLMngIpRangeStart OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Start Address of the range" ::= { bwaVLMngIpRangeEntry 3 } bwaVLMngIpRangeEnd OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. End Address of the range. Used only if bwaVLMngIpRangeFlag is rangeDefinedByStartEndAddr" ::= { bwaVLMngIpRangeEntry 4 } bwaVLMngIpRangeMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. End Address of the range. Used only if bwaVLMngIpRangeFlag is rangeDefinedByStartAddrMask" ::= { bwaVLMngIpRangeEntry 5 } bwaVLDeleteOneNwIpRange OBJECT-TYPE SYNTAX INTEGER (0 | 1..10 | 255) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. 0 - cancel operation. 1..10 - Deletes a single selected entry from the Management IP Ranges Table." ::= { bwaVLNwMngParameters 11 } bwaVLDeleteAllNwIpRanges OBJECT-TYPE SYNTAX INTEGER { deleteAll (1), cancelOperation (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Deletes all entries from the Management IP Ranges Table." ::= { bwaVLNwMngParameters 12 } bwaVLApClientIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB unit only. The IP Address of the WIFI WIMAX unit" ::= { bwaVLNwMngParameters 13 } -- IP Params: -- =========== bwaVLIpParams OBJECT IDENTIFIER ::= {bwaVLMib 4} bwaVLUnitIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. IP address of the unit." ::= { bwaVLIpParams 1 } bwaVLSubNetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Subnet mask of the unit." ::= { bwaVLIpParams 2 } bwaVLDefaultGWAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Default gateway IP address of the unit." ::= { bwaVLIpParams 3 } bwaVLUseDhcp OBJECT-TYPE SYNTAX INTEGER{ disable (1), dhcpOnly (2), automatic (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. DHCP client mode of operation. disabled : Use regular (manual) methods to configure IP parameters. dHCP Only: Use DHCP server to configure IP parameters. automatic: Use DHCP server to configure IP parameters. If a DHCP server is not available, use manually configured values." ::= { bwaVLIpParams 4 } bwaVLAccessToDHCP OBJECT-TYPE SYNTAX INTEGER{ fromWirelessOnly (1), fromEthernetOnly (2), fromBothWirelessAndEthernet (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The port to be used for communicating with a DHCP server." ::= { bwaVLIpParams 5 } bwaVLRunTimeIPaddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The run-time IP address. If DHCP is used the Run Time IP Address is the address given to the unit by the server. Otherwise it is the manually configured address." ::= { bwaVLIpParams 6 } bwaVLRunTimeSubNetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The run-time Subnet Mask. If DHCP is used the Run Time Subnet Mask is the mask given to the unit by the server. Otherwise it is the manually configured mask." ::= { bwaVLIpParams 7 } bwaVLRunTimeDefaultIPGateway OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The run-time Gateway IP address. If DHCP is used the Run Time Gateway IP Address is the address given to the unit by the server. Otherwise it is the manually configured address." ::= { bwaVLIpParams 8 } -- Bridge Params -- ============== bwaVLBridgeParameters OBJECT IDENTIFIER ::= {bwaVLMib 5} bwaVLVLANSupport OBJECT IDENTIFIER ::= {bwaVLBridgeParameters 1} bwaVLVlanID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. VLAN ID for data frame tagging. Applicable to Access Link only. Range: 1 to 4094. 0 - not applicable." ::= { bwaVLVLANSupport 1 } bwaVLEthernetLinkType OBJECT-TYPE SYNTAX INTEGER { accessLink (1), trunkLink (2), hybridLink (3), serviceProviderLink (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. VLAN support mode (Link Type). The Access Link option is not available for AU/BU. Service Provider Link is not available for BU/RB." ::= { bwaVLVLANSupport 2 } bwaVLManagementVlanID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. VLAN ID for management frame tagging. Range: 1 to 4094, 65535 for No VLAN tagging." ::= { bwaVLVLANSupport 3 } bwaVLVLANForwarding OBJECT IDENTIFIER ::= {bwaVLVLANSupport 4} bwaVLVlanForwardingSupport OBJECT-TYPE SYNTAX INTEGER { disable (1) , enable (2), na(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Enables or disables the VLAN forwarding feature. (applicable in Trunk and Service Provider links only)." ::= { bwaVLVLANForwarding 1 } bwaVLVlanForwardingTable OBJECT-TYPE SYNTAX SEQUENCE OF BwaVLVlanForwardingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. A VLAN Forwarding Table of up to 20 VLAN IDs of devices to which data frames are forwarded when VLAN Forwarding is Enabled. (applicable in Trunk and Service Provider links only)." ::= { bwaVLVLANForwarding 2 } bwaVLVlanForwardingEntry OBJECT-TYPE SYNTAX BwaVLVlanForwardingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. A VLAN Forwarding Table entry. (applicable in Trunk and Service Provider links only)." INDEX { bwaVLVlanForwardingTableIdx } ::= { bwaVLVlanForwardingTable 1 } BwaVLVlanForwardingEntry ::= SEQUENCE { bwaVLVlanForwardingTableIdx INTEGER, bwaVLVlanIdForwarding INTEGER } bwaVLVlanForwardingTableIdx OBJECT-TYPE SYNTAX INTEGER (1..20) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. A read only table index for a VLAN entry in the VLAN Forwarding Table." ::= { bwaVLVlanForwardingEntry 1 } bwaVLVlanIdForwarding OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The list of VLAN ID's in the VLAN ID Forwarding Table. To Remove a VLAN ID - SET the corresponding entry to 0. To Add a new VLAN ID SET an entry which is currently 0. Range : 0 to 4094" ::= { bwaVLVlanForwardingEntry 2 } bwaVLVlanRelaying OBJECT IDENTIFIER ::= {bwaVLVLANSupport 5} bwaVLVlanRelayingSupport OBJECT-TYPE SYNTAX INTEGER { disable (1) , enable (2), na(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BWA-PtP products. Enables or disables VLAN Relaying (applicable in Trunk and Service Provider links only)." ::= { bwaVLVlanRelaying 1 } bwaVLVlanRelayingTable OBJECT-TYPE SYNTAX SEQUENCE OF BwaVLVlanRelayingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BWA-PtP products. A VLAN Relaying Table of up to 20 VLAN IDs of devices to which data frames are relayed when VLAN Relaying is Enabled. (applicable in Trunk and Service Provider links only)." ::= { bwaVLVlanRelaying 2 } bwaVLVlanRelayingEntry OBJECT-TYPE SYNTAX BwaVLVlanRelayingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BWA-PtP products. A VLAN Relaying Table entry. (applicable in Trunk and Service Provider links only)." INDEX { bwaVLVlanRelayingTableIdx } ::= { bwaVLVlanRelayingTable 1 } BwaVLVlanRelayingEntry ::= SEQUENCE { bwaVLVlanRelayingTableIdx INTEGER, bwaVLVlanIdRelaying INTEGER } bwaVLVlanRelayingTableIdx OBJECT-TYPE SYNTAX INTEGER (1..20) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BWA-PtP products. A table index for a VLAN entry in the VLAN Relaying Table." ::= { bwaVLVlanRelayingEntry 1 } bwaVLVlanIdRelaying OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BWA-PtP products. The list of VLAN ID's in the VLAN ID Relaying Table. To Remove a VLAN ID - SET the corresponding entry to 0. To Add a new VLAN ID SET an entry which is currently 0. Range: 0 to 4094 , 0 - remove entry." ::= { bwaVLVlanRelayingEntry 2 } bwaVLVLANTrafficPriority OBJECT IDENTIFIER ::= {bwaVLVLANSupport 6} bwaVLVlanDataPriority OBJECT-TYPE SYNTAX INTEGER { na(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. Priority tagging for data frames. Applicable to Access Link only. Range: 0 to 7." ::= { bwaVLVLANTrafficPriority 1 } bwaVLVlanManagementPriority OBJECT-TYPE SYNTAX INTEGER { na(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Priority tagging for management frames. Applicable to Access Link and Trunk Link only. Range: 0 to 7." ::= { bwaVLVLANTrafficPriority 2 } bwaVLVlanPriorityThreshold OBJECT-TYPE SYNTAX INTEGER { na(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Not applicable to units with SW version 3.1 or higher. Priority threshold for tagged frames received from Ethernet port. Applicable to Hybrid Link and Trunk Link only. Valid values: 0-7." ::= { bwaVLVLANTrafficPriority 3 } bwaVLVLANQinQ OBJECT IDENTIFIER ::= {bwaVLVLANSupport 7} bwaVLQinQEthertype OBJECT-TYPE SYNTAX INTEGER (33025 .. 36864|37120|37376) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU and SU. Not applicable to PtP units. The Ethernet type of the Service Provider Tag. The range is 0x8101(33025) - 0x9000(36864), 0x9100(37120), 0x9200(37376)." ::= { bwaVLVLANQinQ 1 } bwaVLQinQProviderVlanID OBJECT-TYPE SYNTAX INTEGER (1..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU only. VLAN ID of the Service Provider Tag." ::= { bwaVLVLANQinQ 2 } bwaVLBridgeAgingTime OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Bridge aging time for devices on both the Ethernet and wireless link sides. Range: 20 to 2000 seconds." ::= { bwaVLBridgeParameters 2 } bwaVLBroadcastRelaying OBJECT-TYPE SYNTAX INTEGER { disable (1), broadcastMulticastEnable (2), broadcastEnable (3), multicastEnable (4), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BWA-PtP products. Enables/disables the relaying of broadcast messages to the wireless link." ::= { bwaVLBridgeParameters 4 } bwaVLUnicastRelaying OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BWA-PtP products. Enables/disables the relaying of unicast messages to the wireless link." ::= { bwaVLBridgeParameters 5 } bwaVLEthBroadcastFiltering OBJECT-TYPE SYNTAX INTEGER { disable (1), onEthernetOnly (2), onWirelessOnly (3), onBothWirelessAndEthernet (4), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. Enables/disables the filtering of Ethernet (layer2) broadcasts. disable : No filtering. onEthernetOnly : Filters broadcasts received on the Ethernet port only. onWirelessOnly : Filters broadcasts received on the Wlan port only. onBothWirelessAndEth: Filters broadcasts received on both ports." ::= { bwaVLBridgeParameters 6 } bwaVLEthBroadcastingParameters OBJECT IDENTIFIER ::= {bwaVLBridgeParameters 7} bwaVLDHCPBroadcastOverrideFilter OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. Enables or disables the broadcasting of DHCP messages, overriding the general *bwaVLEthBroadcastFiltering Ethernet broadcast filtering option." ::= { bwaVLEthBroadcastingParameters 1 } bwaVLPPPoEBroadcastOverrideFilter OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. Enables or disables the broadcasting of PPPoE messages, overriding the general *bwaVLEthBroadcastFiltering Ethernet broadcast filtering option." ::= { bwaVLEthBroadcastingParameters 2 } bwaVLARPBroadcastOverrideFilter OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. Enables or disables the broadcasting of ARP messages, overriding the general *bwaVLEthBroadcastFiltering Ethernet broadcast filtering option." ::= { bwaVLEthBroadcastingParameters 3 } bwaVLEthBroadcastMulticastLimiterOption OBJECT-TYPE SYNTAX INTEGER { disable (1), limitOnlyBroadcasts(2), limitMulticastsExceptBroadcasts(3), limitAllMulticasts(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Enable/disable the limiter for multicast and broadcast packets." ::= { bwaVLEthBroadcastingParameters 4 } bwaVLEthBroadcastMulticastLimiterThreshold OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The limit on the number of multicast and broadcast packets when the Ethernet Broadcast/Multicast Limiter Option is enabled. Range: 0 to 204800" ::= { bwaVLEthBroadcastingParameters 5 } bwaVLEthBroadcastMulticastLimiterSendTrapInterval OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The minimum time between two successive traps that are sent indicating the number of packets that were dropped by the Ethernet Broadcast/Multicast Limiter since the last trap was sent. Range: 1 to 60 minutes" ::= { bwaVLEthBroadcastingParameters 6 } bwaVLToSPriorityParameters OBJECT IDENTIFIER ::= {bwaVLBridgeParameters 8} bwaVLToSPrecedenceThreshold OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Not applicable to units with SW version 3.1 or higher. Priority threshold (based on the ToS) for frames received from the Ethernet port. Range: 0 to 7." ::= { bwaVLToSPriorityParameters 1 } bwaVLRoamingOption OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), na(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. Disable/enable the roaming feature. When enabled, the SU/RB will start scanning for an AU/BU after about one second of not receiving beacons or data from current AU/BU. Once it found a new AU/BU, it will also send through the wireless network a roaming SNAP on behalf of its clients informing other devices in the network of their new location. When disabled, it will wait for about seven seconds before starting scanning, and it will not send a roaming SNAP." ::= { bwaVLBridgeParameters 9 } bwaVLMacAddressDenyList OBJECT IDENTIFIER ::= {bwaVLBridgeParameters 10} bwaVLMacAddressDenyListTable OBJECT-TYPE SYNTAX SEQUENCE OF BwaVLMacAddressDenyListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BWA-PtP units. A list of up to 100 MAC Addresses of SUs. If bwaVLMacAddressDenyListAction is set to denyList, these are SUs that are not allowed to transfer data to the AU. If bwaVLMacAddressDenyListAction is set to allowList, only these SUs are allowed to transfer data to the AU." ::= { bwaVLMacAddressDenyList 1 } bwaVLMacAddressDenyListEntry OBJECT-TYPE SYNTAX BwaVLMacAddressDenyListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BWA-PtP units. An entry in the Mac Address Deny List Table." INDEX { bwaVLMacAddressDenyListTableIdx } ::= { bwaVLMacAddressDenyListTable 1 } BwaVLMacAddressDenyListEntry ::= SEQUENCE { bwaVLMacAddressDenyListTableIdx INTEGER, bwaVLMacAddressDenyListId MacAddress } bwaVLMacAddressDenyListTableIdx OBJECT-TYPE SYNTAX INTEGER (1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BWA-PtP units. A read only table index for a MAC Address entry in the Mac Address Deny List Table. Range: 1 to 100." ::= { bwaVLMacAddressDenyListEntry 1 } bwaVLMacAddressDenyListId OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BWA-PtP units. The list of MAC Addresses in the Mac Address Deny List Table. To Remove a MAC Address - SET the corresponding entry to 0. To Add a new MAC Address - SET an entry which is currently 0." ::= { bwaVLMacAddressDenyListEntry 2 } bwaVLMacAddressDenyListAdd OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BWA-PtP units. Add a MAC address to the MAC Address Deny List Table" ::= { bwaVLMacAddressDenyList 2 } bwaVLMacAddressDenyListRemove OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BWA-PtP units. Delete a MAC address from the MAC Address Deny List Table" ::= { bwaVLMacAddressDenyList 3 } bwaVLNumberOfMacAddressesInDenyList OBJECT-TYPE SYNTAX INTEGER { na(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BWA-PtP units. Number of MAC addresses in the MAC Address Deny List Table." ::= { bwaVLMacAddressDenyList 4 } bwaVLMacAddressDenyListAction OBJECT-TYPE SYNTAX INTEGER { denyList(1), allowedList(2), na(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. Define the action to be used by the Mac Address Deny List. allowedList(2) means that the list becomes Allow list." ::= { bwaVLMacAddressDenyList 5 } bwaVLPortsControl OBJECT IDENTIFIER ::= {bwaVLBridgeParameters 11} bwaVLEthernetPortControl OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2), na(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. Enable/disable the Ethernet port. When disabled, only data frames are blocked. Management frames are accepted." ::= { bwaVLPortsControl 1 } -- Air Interface Params -- ===================== bwaVLAirInterface OBJECT IDENTIFIER ::= {bwaVLMib 6} bwaVLESSIDParameters OBJECT IDENTIFIER ::= {bwaVLAirInterface 1} bwaVLESSID OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The Extended Service Set ID (ESSID) used to prevent the merging of collocated systems. The ESSID is accessible only with the write community string (administrator password). Up to 31 printable case sensitive ASCII characters." ::= { bwaVLESSIDParameters 1 } bwaVLOperatorESSIDOption OBJECT-TYPE SYNTAX INTEGER {disable (1) , enable (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. Enabling/disabling the use of the Operator ESSID." ::= { bwaVLESSIDParameters 2 } bwaVLOperatorESSID OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. A secondary ESSID to support easy installation of SUs as well as the use of the Best AU/BU feature. Accessible only with SNMP Write Community Up to 31 printable case sensitive ASCII characters." ::= { bwaVLESSIDParameters 3} bwaVLRunTimeESSID OBJECT-TYPE SYNTAX DisplayString (SIZE(31)) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. The ESSID of the associated AU/BU. Accessible only with SNMP Write Community. Up to 31 printable ASCII characters, case sensitive." ::= { bwaVLESSIDParameters 4 } bwaVLMaximumCellRadius OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. For AU/BU: read-write. In units with SW version 2.0 and up - applicable only when the Cell Distance Mode is set to Manual. The highest distance from the AU/BU of any SU/RB served by it. Affects the maximum time the units wait for a response message and the slot size by taking into account the round trip propagation delay. For SU/RB: read-only. The distance is learned from the AU/BU. Range: For units below version 2.0 the range is 0 - 50000 Meters. Otherwise - the range is 0 to 54 Kilometers. 0 means no compensation (minimum slot size, maximal delay timeout)." ::= { bwaVLAirInterface 2 } bwaVLAIFS OBJECT-TYPE SYNTAX INTEGER { oneSlot (1), twoSlots (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU and SU. Not applicable to BWA-PtP products. Not applicable if Wireless Link Prioritization is enabled. Arbitration Inter-Frame Spacing (AIFS) value, in slots. This is the number of time slots that define the DIFS. (DIFS=SIFS+AIFS). A value of 1 should be used only in point-to-point applications to allow one unit to have advantage over the other unit." ::= { bwaVLAirInterface 3 } bwaVLWirelessTrapThreshold OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. A wireless link quality threshold, expressed in % of retransmissions, for sending the bwaVLAUWirelessQualityTRAP. This trap indicate whether the quality has gone below or above the specified threshold. The Threshold Range: 1 to 100 (% retransmissions)." ::= { bwaVLAirInterface 4 } bwaVLTransmitPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF BwaVLTransmitPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. A table of transmit power parameters. " ::= { bwaVLAirInterface 5} bwaVLTransmitPowerEntry OBJECT-TYPE SYNTAX BwaVLTransmitPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. An entry in the Transmit Power Table." INDEX { bwaVLTransmitPowerIdx } ::= { bwaVLTransmitPowerTable 1 } BwaVLTransmitPowerEntry ::= SEQUENCE { bwaVLTransmitPowerIdx INTEGER, bwaVLApplicableModulationLevel INTEGER, bwaVLMaximumTxPowerRange DisplayString, bwaVLTxPower DisplayString, bwaVLCurrentTxPower DisplayString } bwaVLTransmitPowerIdx OBJECT-TYPE SYNTAX INTEGER (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. An index of an entry in the Transmit Power Table." ::= { bwaVLTransmitPowerEntry 1 } bwaVLApplicableModulationLevel OBJECT-TYPE SYNTAX INTEGER {level1to5 (1), level6 (2), level7 (3),level8 (4)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The applicable modulation level for an entry in the Transmit Power Table. Level 8 is not applicable to units with HW revision A." ::= { bwaVLTransmitPowerEntry 2 } bwaVLMaximumTxPowerRange OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The allowed range for the bwaVLTxPower parameter at the applicable modulation level . Range: -10 to the maximum allowed power level at the applicable modulation level , in dBm." ::= { bwaVLTransmitPowerEntry 3 } bwaVLTxPower OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Read-only for units with SW version 4.0 and higher. In AU/BU: The transmit power in dBm defined for the applicable rate. In SU/RB: If ATPC is disabled, this is the transmit power in dBm defined for the applicable rate. If ATPC is enabled, it serves as the initial transmit power in dBm for the ATPC algorithm. In SU/RB: The range is -10 dBm to the power value defined by bwaVLMaximumTxPower for the applicable modulation level. In AU/BU: The range is -10 dBm to the power value defined by bwaVLMaximumTxPowerRange for the applicable modulation level." ::= { bwaVLTransmitPowerEntry 4 } bwaVLCurrentTxPower OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB. The actual transmit power in dBm for the applicable rate. Range: -17 to the maximum value defined by bwaVLMaximumTxPowerRange for the applicable modulation level." ::= { bwaVLTransmitPowerEntry 5 } bwaVLMaximumTransmitPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF BwaVLMaximumTransmitPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to SU/RB only. A table of maximum transmit power parameters. " ::= { bwaVLAirInterface 6} bwaVLMaximumTransmitPowerEntry OBJECT-TYPE SYNTAX BwaVLMaximumTransmitPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to SU/RB only. An entry in the Maximum Transmit Power Table." INDEX { bwaVLMaximumTransmitPowerIdx } ::= { bwaVLMaximumTransmitPowerTable 1 } BwaVLMaximumTransmitPowerEntry ::= SEQUENCE { bwaVLMaximumTransmitPowerIdx INTEGER, bwaVLMaxTxApplicableModulationLevel INTEGER, bwaVLDefinedMaximumTxPowerRange DisplayString, bwaVLMaxTxPower DisplayString } bwaVLMaximumTransmitPowerIdx OBJECT-TYPE SYNTAX INTEGER (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. An index of an entry in the Maximum Transmit Power Table." ::= { bwaVLMaximumTransmitPowerEntry 1 } bwaVLMaxTxApplicableModulationLevel OBJECT-TYPE SYNTAX INTEGER {level1to5 (1), level6 (2), level7 (3),level8 (4)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. The applicable modulation level for an entry in the Maximum Transmit Power Table. Level 8 is not applicable to units with HW revision A." ::= { bwaVLMaximumTransmitPowerEntry 2 } bwaVLDefinedMaximumTxPowerRange OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. The allowed range for the bwaVLMaxTxPower parameter at the applicable modulation level . Range: -10 to the maximum allowed power level at the applicable modulation level , in dBm." ::= { bwaVLMaximumTransmitPowerEntry 3 } bwaVLMaxTxPower OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. Read-only for units with SW version 4.0 and higher. The maximum value that can be configured for the bwaVLTxPower parameter. This is also the maximum power level that can be reached by the ATPC algorithm. The range is -10 dBm to the maximum value defined by bwaVLDefinedMaximumTxPowerRange for the applicable modulation level." ::= { bwaVLMaximumTransmitPowerEntry 4 } bwaVLMaxNumOfAssociations OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BWA-PtP products. Sets the upper limit for the number of SUs that can be associated with the AU. Range: For regular AUs (AU-BS, AU-SA) the range is from 0 to 512 if encryption is disabled the range id form 0 to 124 if encryption is enabled For AUS-BS and AUS-SA with SW version 4.0 and higher the range is between 0 to 8 or 25 (via licensing). For AUS-BS and AUS-SA with SW version below 4.0 the range is between 0 to 5. BWA-PtP products return 65535." ::= { bwaVLAirInterface 10 } bwaVLBestAu OBJECT IDENTIFIER ::= {bwaVLAirInterface 11} bwaVLBestAuSupport OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. Disable/enable the Best AU/BU selection mechanism." ::= { bwaVLBestAu 1 } bwaVLBestAuNoOfScanningAttempts OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. The number of scanning attempts to collect information for the Best AU/BU decision. Range: 1 to 255." ::= { bwaVLBestAu 2 } bwaVLPreferredAuMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. The MAC address of the preferred AU/BU (overriding the Best AU/BU selection process). 000000000000 means no preferred AU/BU." ::= { bwaVLBestAu 3 } bwaVLNeighborAuTable OBJECT-TYPE SYNTAX SEQUENCE OF BwaVLNeighborAuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to SU/RB only. A table of data on neighboring AUs/BUs." ::= { bwaVLBestAu 4} bwaVLNeighborAuEntry OBJECT-TYPE SYNTAX BwaVLNeighborAuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to SU/RB only. An entry in the Neighbor AU/BU Table." INDEX { bwaVLNeighborAuIdx } ::= { bwaVLNeighborAuTable 1 } BwaVLNeighborAuEntry ::= SEQUENCE { bwaVLNeighborAuIdx INTEGER, bwaVLNeighborAuMacAdd MacAddress, bwaVLNeighborAuESSID DisplayString, bwaVLNeighborAuSNR INTEGER, bwaVLNeighborAuAssocLoadStatus INTEGER, bwaVLNeighborAuMark INTEGER, bwaVLNeighborAuHwRevision INTEGER, bwaVLNeighborAuCountryCode INTEGER, bwaVLNeighborAuSwVer DisplayString, bwaVLNeighborAuAtpcOption INTEGER, bwaVLNeighborAuAdapModOption INTEGER, bwaVLNeighborAuBurstModeOption INTEGER, bwaVLNeighborAuDfsOption INTEGER, bwaVLNeighborAuConcatenationOption INTEGER, bwaVLNeighborAuLearnCountryCodeBySU INTEGER, bwaVLNeighborAuSecurityMode INTEGER, bwaVLNeighborAuAuthOption INTEGER, bwaVLNeighborAuDataEncyptOption INTEGER, bwaVLNeighborAuPerSuDistanceLearning INTEGER } bwaVLNeighborAuIdx OBJECT-TYPE SYNTAX INTEGER (1..20) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. An index of an entry in the Neighbor AU/BU Table." ::= { bwaVLNeighborAuEntry 1 } bwaVLNeighborAuMacAdd OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. A MAC address of an AU/BU in the Neighbor AU/BU Table." ::= { bwaVLNeighborAuEntry 2 } bwaVLNeighborAuESSID OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. The ESSID of an AU/BU in the Neighbor AU/BU Table. Accessible only with SNMP Write Community." ::= { bwaVLNeighborAuEntry 3 } bwaVLNeighborAuSNR OBJECT-TYPE SYNTAX INTEGER { na (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. The received signal quality (SNR) in dB of an AU/BU in the Neighbor AU/BU Table." ::= { bwaVLNeighborAuEntry 4 } bwaVLNeighborAuAssocLoadStatus OBJECT-TYPE SYNTAX INTEGER { full (1),notFull (2), na (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. Neighbor AU/BU association load status in the Neighbor AU/BU Table." ::= { bwaVLNeighborAuEntry 5 } bwaVLNeighborAuMark OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. Neighbor AU/BU mark in the Neighbor AU/BU Table." ::= { bwaVLNeighborAuEntry 6 } bwaVLNeighborAuHwRevision OBJECT-TYPE SYNTAX INTEGER {hwRevisionA (1), hwRevisionB (2), hwRevisionC (3), hwRevisionD (4), hwRevisionE (5),na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. Neighbor AU/BU HW revision in the Neighbor AU/BU Table." ::= { bwaVLNeighborAuEntry 7 } bwaVLNeighborAuCountryCode OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. Neighbor AU/BU supported country code in the Neighbor AU/BU Table." ::= { bwaVLNeighborAuEntry 8 } bwaVLNeighborAuSwVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. Neighbor AU/BU SW version in the Neighbor AU/BU Table." ::= { bwaVLNeighborAuEntry 9 } bwaVLNeighborAuAtpcOption OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. Neighbor AU/BU ATPC option configuration in the Neighbor AU/BU Table." ::= { bwaVLNeighborAuEntry 10 } bwaVLNeighborAuAdapModOption OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. Neighbor AU/BU adaptive modulation option configuration in the Neighbor AU/BU Table." ::= { bwaVLNeighborAuEntry 11 } bwaVLNeighborAuBurstModeOption OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. Neighbor AU/BU burst mode option configuration in the Neighbor AU/BU Table." ::= { bwaVLNeighborAuEntry 12 } bwaVLNeighborAuDfsOption OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), na(255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. Neighbor AU/BU DFS option configuration in the Neighbor AU/BU Table." ::= { bwaVLNeighborAuEntry 14 } bwaVLNeighborAuConcatenationOption OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. Neighbor AU/BU concatenation option configuration in the Neighbor AU/BU Table." ::= { bwaVLNeighborAuEntry 15 } bwaVLNeighborAuLearnCountryCodeBySU OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU only. Starting with 4.0 is not applicable for BWA 4900 and BWA PtP products. Neighbor AU Learn Country Code by SU configuration in the Neighbor AU Table." ::= { bwaVLNeighborAuEntry 17 } bwaVLNeighborAuSecurityMode OBJECT-TYPE SYNTAX INTEGER {wep(1), aesOCB(2), fips197(3), na(255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. Neighbor AU/BU security mode configuration in the Neighbor AU/BU Table." ::= { bwaVLNeighborAuEntry 18 } bwaVLNeighborAuAuthOption OBJECT-TYPE SYNTAX INTEGER {openSystem (1), sharedKey (2), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. Neighbor AU/BU authentication option configuration in the Neighbor AU/BU Table." ::= { bwaVLNeighborAuEntry 19 } bwaVLNeighborAuDataEncyptOption OBJECT-TYPE SYNTAX INTEGER {disable (1), enable (2), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. Neighbor AU/BU data encryption option configuration in the Neighbor AU/BU Table." ::= { bwaVLNeighborAuEntry 20 } bwaVLNeighborAuPerSuDistanceLearning OBJECT-TYPE SYNTAX INTEGER {disable (1), enable (2), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU only. Neighbor AU per SU distance learning option configuration in the Neighbor AU Table." ::= { bwaVLNeighborAuEntry 21 } bwaVLFrequencyDefinition OBJECT IDENTIFIER ::= {bwaVLAirInterface 12} bwaVLSubBandLowerFrequency OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Applicable to SU only. Not applicable to units with SW version 2.0 or higher. The lowest frequency in the subset to be used for scanning. For 5.8GHz products the range is 5740 to 5830 MHz using 10MHz resolution. For 4.9GHz products the range is 4920 to 5080 MHz using 10MHz resolution. For HW Revision C and above this leaf is not relevant - shall return 0." ::= { bwaVLFrequencyDefinition 1 } bwaVLSubBandUpperFrequency OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Applicable to SU only. Not applicable to units with SW version 2.0 or higher. The highest frequency in the subset to be used for scanning. For 5.8GHz products the range is 5740 to 5830 MHz using 10MHz resolution. For 4.9GHz products the range is 4920 to 5080 MHz using 10MHz resolution. For HW Revision C and above this leaf is not relevant - shall return 0." ::= { bwaVLFrequencyDefinition 2 } bwaVLScanningStep OBJECT-TYPE SYNTAX INTEGER { mhz-5(1), mhz-10(2) , mhz-20(3), na(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units - For flexible Sub-Bands only. For units with version 2.0 and above this is a read-only parameter. The scanning step to be used for generating the frequency subset." ::= { bwaVLFrequencyDefinition 3 } bwaVLFrequencySubsetTable OBJECT-TYPE SYNTAX SEQUENCE OF BwaVLFrequencySubsetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to SU/RB and to AU/BU. Not applicable to SU/RB with SW version 4.0 and higher. The Frequency Subset Table that includes all frequencies from the selected Sub-band." ::= { bwaVLFrequencyDefinition 4 } bwaVLFrequencySubsetEntry OBJECT-TYPE SYNTAX BwaVLFrequencySubsetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to SU/RB and to AU/BU. Not applicable to SU/RB with SW version 4.0 and higher. An entry in the Frequency Subset Table. " INDEX { bwaVLFrequencySubsetTableIdx } ::= { bwaVLFrequencySubsetTable 1 } BwaVLFrequencySubsetEntry ::= SEQUENCE { bwaVLFrequencySubsetTableIdx INTEGER, bwaVLFrequencySubsetFrequency INTEGER, bwaVLFrequencySubsetActive INTEGER, bwaVLFrequencySubsetFrequencyNew DisplayString } bwaVLFrequencySubsetTableIdx OBJECT-TYPE SYNTAX INTEGER (1..40) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB and to AU/BU. Not applicable to SU/RB with SW version 4.0 and higher. An index of an entry in the Frequency subset Table." ::= { bwaVLFrequencySubsetEntry 1 } bwaVLFrequencySubsetFrequency OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB and to AU/BU. Not applicable to SU/RB with SW version 4.0 and higher. Applicable to all units with HW revision B and lower (for units with HW revision C and higher replaced by bwaVLFrequencySubsetFrequencyNew to support a resolution of 0.5 MHz). The frequency in MHz of an entry in the Frequency Subset table." ::= { bwaVLFrequencySubsetEntry 2 } bwaVLFrequencySubsetActive OBJECT-TYPE SYNTAX INTEGER {active (1) , notActive (2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB and to AU/BU. Not applicable to SU/RB with SW version 4.0 and higher. The status of an entry in the Frequency subset Table. The frequency of an active entry will be included in the final list of frequencies to be used for scanning." ::= { bwaVLFrequencySubsetEntry 3 } bwaVLFrequencySubsetFrequencyNew OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Not applicable to SU/RB with SW version 4.0 and higher. The frequency in MHz of an entry in the Frequency Subset table. (Replaces bwaVLFrequencySubsetFrequency to support a resolution of 0.5 MHz for units with HW revision C and higher)." ::= { bwaVLFrequencySubsetEntry 4 } bwaVLSetSelectedFreqSubset OBJECT-TYPE SYNTAX INTEGER {setSelectedFreqsSubset(1) ,cancel (2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB and to AU/BU. Not applicable to SU/RB with SW version 4.0 and higher. Apply the selected subset. After the next reset the new subset will be used." ::= { bwaVLFrequencyDefinition 5 } bwaVLCurrentFrequencySubsetTable OBJECT-TYPE SYNTAX SEQUENCE OF BwaVLCurrentFrequencySubsetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to SU/RB and to AU/BU. Not applicable to SU/RB with SW version 4.0 and higher. The Current Frequency Subset table. In SU/RB it includes all frequencies that are currently used for scanning. In AU/BU it includes all frequencies that can be used by the DFS mechanism (if applicable)" ::= { bwaVLFrequencyDefinition 6 } bwaVLCurrentFrequencySubsetEntry OBJECT-TYPE SYNTAX BwaVLCurrentFrequencySubsetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to SU/RB and to AU/BU. An entry in the Current Frequency Subset Table. " INDEX { bwaVLCurrentFrequencySubsetTableIdx } ::= { bwaVLCurrentFrequencySubsetTable 1 } BwaVLCurrentFrequencySubsetEntry ::= SEQUENCE { bwaVLCurrentFrequencySubsetTableIdx INTEGER, bwaVLCurrentFrequencySubsetFrequency INTEGER, bwaVLCurrentFrequencySubsetFrequencyNew DisplayString } bwaVLCurrentFrequencySubsetTableIdx OBJECT-TYPE SYNTAX INTEGER (1..40) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB and to AU/BU. An index of an entry in the Current Frequency subset Table. Not applicable to SU/RB with SW version 4.0 and higher." ::= { bwaVLCurrentFrequencySubsetEntry 1 } bwaVLCurrentFrequencySubsetFrequency OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Not applicable to SU/RB with SW version 4.0 and higher. Applicable to all units with HW revision B and lower (for units with HW revision C and higher replaced by bwaVLCurrentFrequencySubsetFrequencyNew to support a resolution of 0.5 MHz). The frequency in MHz of an entry in the Current Frequency Subset table." ::= { bwaVLCurrentFrequencySubsetEntry 2 } bwaVLCurrentFrequencySubsetFrequencyNew OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Not applicable to SU/RB with SW version 4.0 and higher. The frequency in MHz of an entry in the Current Frequency Subset table. (Replaces bwaVLCurrentFrequencySubsetFrequency to support a resolution of 0.5 MHz for units with HW revision C and higher)." ::= { bwaVLCurrentFrequencySubsetEntry 3 } bwaVLCurrentAUOperatingFrequency OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU with HW revision B and lower (for units with HW revision C and higher replaced by bwaVLCurrentUOperatingFrequencyNew to support a resolution of 0.5 MHz). The operating frequency in MHz. For 5.8GHz products with SW version below 2.0 the range is 5740 to 5830 MHz using 10MHz resolution. For units with SW version 2.0 and up the range is as defined in the selected Sub Band." ::= { bwaVLFrequencyDefinition 7 } bwaVLCurrentAUOperatingFrequencyNew OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU. The operating frequency in MHz. (Replaces bwaVLCurrentAUOperatingFrequency to support a resolution of 0.5 MHz for units with HW revision C and higher). For 5.8GHz products with SW version below 2.0 the range is 5740 to 5830 MHz using 10MHz resolution. For units with SW version 2.0 and up the range is as defined in the selected Sub Band." ::= { bwaVLFrequencyDefinition 13 } bwaVLAUDefinedFrequency OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU with HW revision B and lower (for units with HW revision C and higher replaced by bwaVLAUDefinedFrequencyNew to support a resolution of 0.5 MHz). For 5.8GHz products with SW version below 2.0 this is the frequency in MHz of the AU/BU after the next reset. For units with SW version 2.0 and up this is the frequency in MHz to use when the DFS Option is disabled. For 5.8GHz products with SW version below 2.0 the range is 5740 to 5830 MHz using 10MHz resolution. For units with SW version 2.0 and up the range is as defined in the selected Sub Band." ::= { bwaVLFrequencyDefinition 8 } bwaVLAUDefinedFrequencyNew OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU. For 5.8GHz products with SW version below 2.0 this is the frequency in MHz of the AU/BU after the next reset. For units with SW version 2.0 and up this is the frequency in MHz to use when the DFS Option is disabled. (Replaces bwaVLAUDefinedFrequency to support a resolution of 0.5 MHz for units with HW revision C and higher). For 5.8GHz products with SW version below 2.0 the range is 5740 to 5830 MHz using 10MHz resolution. For units with SW version 2.0 and up the range is as defined in the selected Sub Band." ::= { bwaVLFrequencyDefinition 14 } bwaVLCurrentSUOperatingFrequency OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. The frequency used currently by the unit. For 5.8GHz products with SW version below 2.0 the range is 5740 to 5830 MHz using 10MHz resolution. For units with SW version 2.0 and up the range is as defined in the selected Sub Band." ::= { bwaVLFrequencyDefinition 9 } bwaVLSubBandSelect OBJECT IDENTIFIER ::= {bwaVLFrequencyDefinition 10} bwaVLSelectSubBandIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units with SW version below 4.0 For units with SW version 4.0 and up it is applicable only for AU/BU. For SU/RB it defines only the sub-band for the Spectrum Analyzer. The ID of the sub-band used by the unit." ::= { bwaVLSubBandSelect 1 } bwaVLDFSParameters OBJECT IDENTIFIER ::= {bwaVLFrequencyDefinition 11} bwaVLDFSOption OBJECT-TYPE SYNTAX INTEGER { disable (1) , enable (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. Enabling/disabling the DFS Algorithm. Not applicable if DFS Option is not supported by the current Sub Band." ::= { bwaVLDFSParameters 1 } bwaVLDFSChannelCheckTime OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. Defines the time the unit checks the channel for presence of radar signals and does not transmit after power up or association or after moving to a new channel due to detecting radar in the used channel. Range: 1 to 3600 (seconds)." ::= { bwaVLDFSParameters 3 } bwaVLDFSChannelAvoidancePeriod OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. Defines the time after detecting radar signals in a channel of avoiding using the channel or adjacent channels in accordance with the bandwidth. Range: 1 to 60 (minutes)." ::= { bwaVLDFSParameters 4 } bwaVLDFSSuWaitingOption OBJECT-TYPE SYNTAX INTEGER { disable (1) , enable (2), na(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. Defines whether the associated SUs should wait for this AU/BU after it stopped transmitting due to radar detection, before they starts scanning for other AUs/BUs." ::= { bwaVLDFSParameters 5 } bwaVLDFSClearRadarDetectedChannelsAfterReset OBJECT-TYPE SYNTAX INTEGER { cancel (1), clearRadarChannels (2), na(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. Clear Radar Detected and Adjacent to Radar channels after unit reset. Returns the unit to operate in default frequency." ::= { bwaVLDFSParameters 6 } bwaVLDFSRadarDetectionChannelsTable OBJECT-TYPE SYNTAX SEQUENCE OF BwaVLDFSRadarDetectionChannelsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to AU/BU only. Applicable only when DFS option is on. Displays the current channels defined in the sub-band and their radar detection status." ::= { bwaVLDFSParameters 7 } bwaVLDFSRadarDetectionChannelsEntry OBJECT-TYPE SYNTAX BwaVLDFSRadarDetectionChannelsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to AU/BU only. An entry in the bwaVLDFSRadarDetectionChannelsTable." INDEX { bwaVLDFSChannelIdx } ::= { bwaVLDFSRadarDetectionChannelsTable 1 } BwaVLDFSRadarDetectionChannelsEntry ::= SEQUENCE { bwaVLDFSChannelIdx INTEGER, bwaVLDFSChannelFrequency INTEGER, bwaVLDFSChannelRadarStatus INTEGER, bwaVLDFSChannelFrequencyNew DisplayString } bwaVLDFSChannelIdx OBJECT-TYPE SYNTAX INTEGER (1..40) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Read-only. The index of the entry in the bwaVLDFSRadarDetectionChannelsTable." ::= { bwaVLDFSRadarDetectionChannelsEntry 1 } bwaVLDFSChannelFrequency OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU with HW revision B and lower (for units with HW revision C and higher replaced by bwaVLDFSChannelFrequency New to support a resolution of 0.5 MHz). The frequency in MHz of a channel in the DFS Radar Detection Channels Table." ::= { bwaVLDFSRadarDetectionChannelsEntry 2 } bwaVLDFSChannelRadarStatus OBJECT-TYPE SYNTAX INTEGER { radarFree (1), adjacentToRadar (2), radarDetected (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The radar detection status of a channel in bwaVLDFSRadarDetectionChannelTable." ::= { bwaVLDFSRadarDetectionChannelsEntry 3 } bwaVLDFSChannelFrequencyNew OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU. The frequency of a channel in the DFS Radar Detection Channels Table. (Replaces bwaVLDFSChannelFrequency to support a resolution of 0.5 MHz for units with HW revision C and higher)." ::= { bwaVLDFSRadarDetectionChannelsEntry 4 } bwaVLDFSMinimumPulsesToDetect OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. Defines the minimum number of pulses to detect a radar. Range: 1 - 100." ::= { bwaVLDFSParameters 8 } bwaVLDFSChannelReuseParameters OBJECT IDENTIFIER ::= {bwaVLDFSParameters 9} bwaVLDFSChannelReuseOption OBJECT-TYPE SYNTAX INTEGER { disable (1) , enable (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. Enabling/disabling the DFS Channel Reuse Algorithm. Not applicable if DFS Option is not supported by the current Sub Band." ::= { bwaVLDFSChannelReuseParameters 1 } bwaVLDFSRadarActivityAssessmentPeriod OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. Range: 1 to 12 (Houres)." ::= { bwaVLDFSChannelReuseParameters 2 } bwaVLDFSMaximumNumberOfDetectionsInAssessmentPeriod OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. Range: 1 to 10 (Times)." ::= { bwaVLDFSChannelReuseParameters 3 } bwaVLCountryCodeLearningBySU OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2), na(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. Starting with 4.0 it is nor applicable for BWA 4900 and BWA PtP. Defines whether the SUs learn the country code of the AU." ::= { bwaVLFrequencyDefinition 12 } -- AUTOMATIC SUB BAND SELECT BEGIN bwaVLAutoSubBandSelect OBJECT IDENTIFIER ::= { bwaVLFrequencyDefinition 15 } bwaVLAutoSubBandSelectedFreqSubset OBJECT-TYPE SYNTAX INTEGER { setAllSelectedFreqsSubset(1), cancel (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB with SW version 4.0 and higher. Apply the selected subset. After the next reset the new subset will be used for scanning." ::= { bwaVLAutoSubBandSelect 1 } bwaVLAutoSubBandFrequencySubsetTable OBJECT-TYPE SYNTAX SEQUENCE OF BwaVLAutoSubBandFrequencySubsetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to SU/RB with SW version 4.0 and higher. The Frequency Subset Table that includes all available sub-bands and all the frequencies in these sub-bands." ::= { bwaVLAutoSubBandSelect 2 } bwaVLAutoSubBandFrequencySubsetEntry OBJECT-TYPE SYNTAX BwaVLAutoSubBandFrequencySubsetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to SU/RB with SW version 4.0 and higher. An entry in the Frequency Subset Table. " INDEX { bwaVLAutoSubBandFrequencySubsetBandIdx, bwaVLAutoSubBandFrequencySubsetFrequencyIdx } ::= { bwaVLAutoSubBandFrequencySubsetTable 1 } BwaVLAutoSubBandFrequencySubsetEntry ::= SEQUENCE { bwaVLAutoSubBandFrequencySubsetBandIdx INTEGER, bwaVLAutoSubBandFrequencySubsetFrequencyIdx INTEGER, bwaVLAutoSubBandFrequencySubsetActive INTEGER, bwaVLAutoSubBandFrequencySubsetFrequency DisplayString } bwaVLAutoSubBandFrequencySubsetBandIdx OBJECT-TYPE SYNTAX INTEGER (1..5) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB with SW version 4.0 and higher. The index of the applicable Sub Band. This is the Sub Band ID of the relevant entry in the Country Dependent Parameters table. Serves also as an index of the entry in the Frequency subset Table." ::= { bwaVLAutoSubBandFrequencySubsetEntry 1 } bwaVLAutoSubBandFrequencySubsetFrequencyIdx OBJECT-TYPE SYNTAX INTEGER (1..40) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB with SW version 4.0 and higher. The index of the applicable frequency in the applicable Sub Band. Serves also as an index of the entry in the Frequency subset Table." ::= { bwaVLAutoSubBandFrequencySubsetEntry 2 } bwaVLAutoSubBandFrequencySubsetActive OBJECT-TYPE SYNTAX INTEGER {active (1) , notActive (2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB with SW version 4.0 and higher. The status of an entry in the Auto Sub Band Frequency subset Table. The frequency of an active entry will be included in the final list of frequencies to be used for scanning." ::= { bwaVLAutoSubBandFrequencySubsetEntry 3 } bwaVLAutoSubBandFrequencySubsetFrequency OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB with SW version 4.0 and higher. The frequency in MHz of the entry in the Auto Sub Band Frequency Subset table." ::= { bwaVLAutoSubBandFrequencySubsetEntry 4 } -- AUTOMATIC SUB BAND SELECT END bwaVLATPC OBJECT IDENTIFIER ::= {bwaVLAirInterface 13} bwaVLAtpcOption OBJECT-TYPE SYNTAX INTEGER { disable (1) , enable (2) , na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable all units. Enabling/disabling the ATPC Algorithm." ::= { bwaVLATPC 1 } bwaVLDeltaFromMinSNRLevel OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable AU/BU only. The Minimum SNR Level plus the value of this parameter define the maximum desired level of the average SNR at the AU/BU. If the ATPC Option is enabled, than if the received SNR is above the maximum desired level, the AU/BU will transmit Power-Down messages to the applicable SU/RB. Range: 4 to 20 (dB)." ::= { bwaVLATPC 2 } bwaVLMinimumSNRLevel OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable AU/BU only. Defines the minimum desired level of the average SNR at the AU/BU. Below this level, if *AtpcOption is enabled, the AU/BU will transmit ATPC Power-Up messages to the applicable SU/RB. The *MinimumSNRLevel cannot be higher than *MaximumSNRLevel. Range: 4 to 60 (dB)." ::= { bwaVLATPC 3 } bwaVLMinimumIntervalBetweenATPCMessages OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable AU/BU only. The minimum interval between two consecutive AU/BU to SU/RB messages. Range: 1 to 3600 (Sec)." ::= { bwaVLATPC 4 } bwaVLPowerLevelSteps OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable AU/BU only. The step in dB that the SU/RB will use when receiving an ATPC Power-Up/Power-Down message. Range: 1 to 20 (dB)." ::= { bwaVLATPC 6 } bwaVLCellDistanceParameters OBJECT IDENTIFIER ::= {bwaVLAirInterface 15} bwaVLCellDistanceMode OBJECT-TYPE SYNTAX INTEGER { automatic (1) , manual (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable AU/BU only. The selected mode of deciding on Cell Distance." ::= { bwaVLCellDistanceParameters 1 } bwaVLFairnessFactor OBJECT-TYPE SYNTAX INTEGER { na (255)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable AU/BU only. Not applicable to BWA-PtP products for SW version below 4.0.. The percentage of the maximum distance that is taken into account in the time slot calculation. Range: 0 to 100 (Percent). A value of 0 means the minimal slot size (9 microseconds). BWA-PtP products with SW version below 4.0 return na." ::= { bwaVLCellDistanceParameters 2 } bwaVLMeasuredCellDistance OBJECT-TYPE SYNTAX INTEGER {below-2-Km(1)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable AU/BU only. The Maximum Cell Distance as calculated by the AU/BU. Range: 0 to 54 (Kilometers)." ::= { bwaVLCellDistanceParameters 3 } bwaVLUnitWithMaxDistance OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable AU only. Not applicable to BWA-PtP units. The MAC address of the unit with the maximum distance from the AU." ::= { bwaVLCellDistanceParameters 4 } bwaVLPerSuDistanceLearning OBJECT-TYPE SYNTAX INTEGER { disable (1) , enable (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Aplicable to AU only. Applicable only if Cell Distance Mode is set to Automatic. When disabled, all SUs in the cell will use for the ACK Timeout the computed distance of the farthest SU. When enabled, each SU will use its own computed distance" ::= { bwaVLCellDistanceParameters 5 } bwaVLScanningMode OBJECT-TYPE SYNTAX INTEGER { passive (1), active (2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. The scanning mode. In cells where the DFS Option is enabled Scanning Mode is forced to Passive." ::= { bwaVLAirInterface 16 } bwaVLAntennaGain OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Read-write in units where bwaVLAntennaGainChange is supported. Read-only in units where bwaVLAntennaGainChange is not supported. The net gain (including cable attenuation for detached antennas) of the antenna. Range: 0 - to Maximum EIRP defined by country code + 10 (dBi). A value of -2 (this value is configurable only in factory) means don't care. A value of -1 (this value is configurable only in factory) means that the unit will not transmit until the actual value is configured." ::= { bwaVLAirInterface 17 } bwaVLSpectrumAnalysisParameters OBJECT IDENTIFIER ::= {bwaVLAirInterface 18} bwaVLSpectrumAnalysisChannelScanPeriod OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The period of staying on each channel for information gathering when performing Spectrum analysis. Range: 2-30 seconds." ::= { bwaVLSpectrumAnalysisParameters 1 } bwaVLSpectrumAnalysisScanCycles OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The number of scanning cycles when performing Spectrum Analysis. Range: 1-100." ::= { bwaVLSpectrumAnalysisParameters 2 } bwaVLAutomaticChannelSelection OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), na (255)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. Defines weather the AU/BU shall choose the most noise free channel upon startup after spectrum analysis." ::= { bwaVLSpectrumAnalysisParameters 3 } bwaVLSpectrumAnalysisActivation OBJECT-TYPE SYNTAX INTEGER { cancelOperation (1), activateNow (2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Activates spectrum analysis, the unit is automatically reset upon activation." ::= { bwaVLSpectrumAnalysisParameters 4 } bwaVLSpectrumAnalysisStatus OBJECT-TYPE SYNTAX INTEGER { inactive (1), currentlyActive (2)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Defines weather the unit is currently under performing a spectrum analysis process." ::= { bwaVLSpectrumAnalysisParameters 5 } bwaVLResetSpectrumCounters OBJECT-TYPE SYNTAX INTEGER { cancelOperation (1), resetCounters (2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Resets the spectrum analysis counters." ::= { bwaVLSpectrumAnalysisParameters 6 } bwaVLSpectrumAnalysisInformationTable OBJECT-TYPE SYNTAX SEQUENCE OF BwaVLSpectrumAnalysisInformationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. The spectrum analysis information table." ::= { bwaVLSpectrumAnalysisParameters 7 } bwaVLSpectrumAnalysisInformationEntry OBJECT-TYPE SYNTAX BwaVLSpectrumAnalysisInformationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. The spectrum analysis information table entry." INDEX { bwaVLSpectrumAnalysisInformationTableIdx } ::= { bwaVLSpectrumAnalysisInformationTable 1 } BwaVLSpectrumAnalysisInformationEntry ::= SEQUENCE { bwaVLSpectrumAnalysisInformationTableIdx INTEGER, bwaVLSpectrumAnalysisInformationChannel DisplayString, bwaVLSpectrumAnalysisInformationSignalCount INTEGER, bwaVLSpectrumAnalysisInformationSignalSNR INTEGER, bwaVLSpectrumAnalysisInformationSignalWidth INTEGER, bwaVLSpectrumAnalysisInformationOFDMFrames INTEGER } bwaVLSpectrumAnalysisInformationTableIdx OBJECT-TYPE SYNTAX INTEGER (1..60) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. A read only table index for a Spectrum Analysis Information entry in the Spectrum Analysis Information Table." ::= { bwaVLSpectrumAnalysisInformationEntry 1 } bwaVLSpectrumAnalysisInformationChannel OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The channels in the Spectrum Analysis Information Table. If the unit is currently under spectrum analysis the channels would be those on which the analysis is currently performed. If the unit is in normal mode the channels would be the those on which the last analysis was performed." ::= { bwaVLSpectrumAnalysisInformationEntry 2 } bwaVLSpectrumAnalysisInformationSignalCount OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of signals (excluding OFDM frames) detected in the channel. If the unit is currently under spectrum analysis the count would be of the analysis that is currently performed. If the unit is in normal mode the count would be of the last analysis performed." ::= { bwaVLSpectrumAnalysisInformationEntry 3 } bwaVLSpectrumAnalysisInformationSignalSNR OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The approximate SNR of the signals (excluding OFDM frames) detected in the channel. If the unit is currently under spectrum analysis the SNR would be of the analysis that is currently performed. If the unit is in normal mode the SNR would be of the last analysis performed." ::= { bwaVLSpectrumAnalysisInformationEntry 4 } bwaVLSpectrumAnalysisInformationSignalWidth OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The average width of the signals (excluding OFDM frames) detected in the channel. If the unit is currently under spectrum analysis the width would be of the analysis that is currently performed. If the unit is in normal mode the width would be of the last analysis performed." ::= { bwaVLSpectrumAnalysisInformationEntry 5 } bwaVLSpectrumAnalysisInformationOFDMFrames OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of OFDM frames detected in the channel. If the unit is currently under spectrum analysis the count would be of the analysis that is currently performed. If the unit is in normal mode the count would be of the last analysis performed." ::= { bwaVLSpectrumAnalysisInformationEntry 6 } bwaVLMaxNumOfAssociationsLimit OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BWA-PtP products. Shows the limit for the number of SUs that can be associated with the AU. For AU-BS, AU-SA if Data Encryption is enabled, the upper limit is 124, otherwise it is 512. For AUS-BS, AUS-SA with SW version 4.0 and higher the upper limit is 8 or 25 (via licensing). For AUS-BS, AUS-SA with SW version below 4.0 the upper limit is 5. BWA-PtP products return 65535." ::= { bwaVLAirInterface 19 } bwaVLDisassociate OBJECT IDENTIFIER ::= {bwaVLAirInterface 20} bwaVLDisassociateAllSUs OBJECT-TYPE SYNTAX INTEGER { cancelOperation (1), disassociateAllSUs(2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. The AU shall disassociate all its associated units." ::= { bwaVLDisassociate 1 } bwaVLDisassociateSuByMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. The AU shall disassociate the SU with the configured MAC address." ::= { bwaVLDisassociate 2 } bwaVLTxControl OBJECT-TYPE SYNTAX INTEGER { on (1), off(2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. Tx Control of the AU/BU. Starting with version 4.0 it is run-time. For SW version below 4.0 the unit reset itself. If set to ethernetStatusControl, the unit will not transmit if the Ethernet link is down. This parameter can be configured only via the ethernet port." ::= { bwaVLAirInterface 21 } bwaVLLostBeaconsWatchdogThreshold OBJECT-TYPE SYNTAX INTEGER ( 0 | 100..1000 ) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. The number of unsuccessful consecutive transmissions beacons before Internal refresh is performed. 0 means that the lost beacons watchdog is not used and internal refresh is not performed." ::= { bwaVLAirInterface 22} bwaVLTransmitPower OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units with SW version 4.0 and higher. The uniform transmit power for all modulation levels. For a specific modulation level the effective transmit power (bwaVLTxPower) is the minimum between the uniform transmit power and the maximum transmit power for that modulation level." ::= { bwaVLAirInterface 23 } bwaVLMaximumTxPower OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to only SU/RB with SW version 4.0 and higher. The Maximum Transmit Power for all modulation levels. The Maximum Transmit Power for a specific modulation level is the minimum between this parameter and the hardware limitation for that modulation level" ::= { bwaVLAirInterface 24 } bwaVLCountryCodeParameters OBJECT IDENTIFIER ::= {bwaVLAirInterface 25} bwaLCountryCodeReApply OBJECT-TYPE SYNTAX INTEGER { reapply(1),cancel(2), na(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Re-apply country code parameters." ::= { bwaVLCountryCodeParameters 1 } -- Service Params -- ============== bwaVLServiceParameters OBJECT IDENTIFIER ::= {bwaVLMib 7} -- bwaVLMirCirOption OBJECT-TYPE -- SYNTAX INTEGER {disable (1), -- enable (2), -- na (255)} -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "Applicable to AU and SU. Read-only in SU. -- The setting in the AU enables/disables the MIR/CIR support -- feature for all SUs served by the AU." -- ::= { bwaVLServiceParameters 1 } bwaVLMirDownlink OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. The Maximum Information Rate (MIR) from AU/BU to SU/RB. MIR must be above bwaVLCirDownlink value. Range for set: 128 to 2,048 (Kbps) for SU-3 with SW version below 4.0, 128 to 3,072 (Kbps) for SU-3 with SW version 4.0 and higher, 128 to 3,968 (Kbps) for SU-6 with SW version less than 4.0, 128 to 6,016 (Kbps) for SU-6 with SW version greater than 4.0, 128 to 14,976 (Kbps) for SU-24, 128 to 53,888 (Kbps) for SU-BD and SU-54, 128 to 6,912 (Kbps) for RB-14, 128 to 22,016 (Kbps) for RB-28, 128 to 107,904 (Kbps) for RB-100. 128 to 6,016 (Kbps) for SU-I. The actual value (Get) will be the entered value rounded to the nearest multiple of 128 (N*128)." ::= { bwaVLServiceParameters 2 } bwaVLMirUplink OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. The Maximum Information Rate (MIR) from SU/RB to AU/BU. MIR must be above bwaVLCirUplink value. Range for set: 128 to 2,048 (Kbps) for SU-3, 128 to 3,968 (Kbps) for SU-6 with SW version less than 4.0, 128 to 4,096 (Kbps) for SU-6 with SW version greater than 4.0, 128 to 14,976 (Kbps) for SU-24, 128 to 53,888 (Kbps) for SU-BD and SU-54, 128 to 6,912 (Kbps) for RB-14, 128 to 22,016 (Kbps) for RB-28, 128 to 107,904 (Kbps) for RB-100. 128 to 2,048 (Kbps) for SU-I. The actual value (Get) will be the entered value rounded to the nearest multiple of 128 (N*128)." ::= { bwaVLServiceParameters 3 } bwaVLCirDownlink OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU only. Not applicable to BWA-PtP products. The Committed Information Rate (CIR) from AU to SU. CIR must be below bwaVLMirDownlink value. Range for Set: 0 to 2,048 (Kbps) for SU-3 with SW version below 4.0, 0 to 3,072 (Kbps) for SU-3 with SW version 4.0 and higher, 0 to 3,968 (Kbps) for SU-6 with SW version less than 4.0, 0 to 6,016 (Kbps) for SU-6 with SW version greater than 4.0 0 to 14,976 (Kbps) for SU-24, 0 to 45,056 (Kbps) for SU-BD and SU-54. 0 to 6,016 (Kbps) for SU-I. The actual value (Get) will be the entered value rounded to the nearest multiple of 128 (N*128). BWA-PtP products will return 65535." ::= { bwaVLServiceParameters 4 } bwaVLCirUplink OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU only. Not applicable to BWA-PtP products. The Committed Information Rate (CIR) from SU to AU. CIR must be below bwaVLMirUplink value. Range for Set: 0 to 2,048 (Kbps) for SU-3, 0 to 3,968 (Kbps) for SU-6 with SW version less than 4.0, 0 to 4,096 (Kbps) for SU-6 with SW version greater than 4.0, 0 to 14,976 (Kbps) for SU-24, 0 to 45,056 (Kbps) for SU-BD and SU-54. 0 to 2,048 (Kbps) for SU-I. The actual value (Get) will be the entered value rounded to the nearest multiple of 128 (N*128). BWA-PtP products will return 65535." ::= { bwaVLServiceParameters 5 } bwaVLMaxDelay OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU only. Not applicable to BWA-PtP products. The maximal time packets may be delayed by the CIR\MIR mechanism. Above the configured maximal period the packets are discarded. Range: 300 to 10000 milliseconds. BWA-PtP products return 65535." ::= { bwaVLServiceParameters 6 } bwaVLMaxBurstDuration OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU and SU. Not applicable to BWA-PtP products. The maximum time during which inactivity bonus time can be accumulated for future burst transmissions. Range: 0 to 2000 milliseconds. BWA-PtP products return 65535" ::= { bwaVLServiceParameters 7 } bwaVLGracefulDegradationLimit OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BWA-PtP products. The maximum limit for activating the graceful degradation algorithm. Range: 0 to 70% rate of the CIR. BWA-PtP products return 255." ::= { bwaVLServiceParameters 8 } bwaVLMirOnlyOption OBJECT-TYPE SYNTAX INTEGER {disable (1), enable (2), na (255)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. Not applicable to BWA-PtP products. When bwaMirOnly is enabled, it overrides the CIR/MIR algorithm for determining actual information rate and forces the algorithm to operate with MIR parameter settings only. When enabled, the Graceful Degradation algorithm is disabled." ::= { bwaVLServiceParameters 9 } bwaVLTrafficPrioritization OBJECT IDENTIFIER ::= {bwaVLServiceParameters 10} bwaVLTrafficPriVLAN OBJECT IDENTIFIER ::= {bwaVLTrafficPrioritization 1} bwaVLVLANPriorityThreshold OBJECT-TYPE SYNTAX INTEGER (1..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. If the VLAN Priority's value of the frame is less than or equal to this threshold the frame will get LOW priority, otherwise the frame will get HIGH priority. Untagged frames will get LOW priority" ::= { bwaVLTrafficPriVLAN 1 } bwaVLTrafficPriIPToS OBJECT IDENTIFIER ::= {bwaVLTrafficPrioritization 2} bwaVLToSPrioritizationOption OBJECT-TYPE SYNTAX INTEGER {disable(1), ipPrecedence(2), dSCP(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Disable/Enable IP ToS prioritization and choose the interpretation of the IP ToS field from IP header. ipPrecedence(2): The IP ToS field is defined by RFC791. In this case the prioritization will be done using the Precedence sub-field of IP ToS. This sub-field has 3 bits, so it can be between 0 and 7. dSCP(3): The IP ToS field is defined by RFC2474. In this case the prioritization will be done using the DSCP sub-field. The size of the sub-field is 6 bits, so the range is 0 to 63." ::= { bwaVLTrafficPriIPToS 1 } bwaVLIPPrecedenceThreshold OBJECT-TYPE SYNTAX INTEGER (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The threshold of Precedence sub-field of IP ToS field from IP Header (RFC791) to be used when the ToS Prioritization Option is set to IP Precedence. If the Precedence sub-field of a frame is less than or equal to this threshold the frame will have LOW priority, otherwise it will get HIGH priority." ::= { bwaVLTrafficPriIPToS 2 } bwaVLIPDSCPThreshold OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The threshold of DSCP sub-field of IP ToS field from IP Header (RFC2474) to be used when ToS Prioritization Option is set to DSCP. If the DSCP sub-field of a frame is less than or equal to this threshold the frame will have LOW priority, otherwise it will get HIGH priority." ::= { bwaVLTrafficPriIPToS 3 } bwaVLTrafficPriUdpTcpPortRange OBJECT IDENTIFIER ::= {bwaVLTrafficPrioritization 3} bwaVLUdpTcpPortRangePrioritizationOption OBJECT-TYPE SYNTAX INTEGER {disable(1), udpOnly(2), tcpOnly(3), udpANDtcp(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Disable/Enable Prioritization using UDP and/or TCP Port Ranges. udpOnly(2) : prioritization will be done only for UDP packets tcpOnly(3) : prioritization will be done only for TCP packets udpANDtcp(4): prioritization will be done for UDP and TCP packets" ::= { bwaVLTrafficPriUdpTcpPortRange 1 } bwaVLUdpPortRangeConfig OBJECT IDENTIFIER ::= {bwaVLTrafficPriUdpTcpPortRange 2} bwaVLUdpPortPriRTPRTCP OBJECT-TYPE SYNTAX INTEGER {rtpANDrtcp(1),rtpOnly(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicale to all units. RTP/RTCP ports prioritization option for UDP packets. rtpANDrtcp(1): the possible RTP and RTCP packet with destination port in the defined port ranges will get HIGH priority rtpOnly(2): only possible RTP packet (packet with even destination port ) with destination port in the defined port ranges will get HIGH priority." ::= { bwaVLUdpPortRangeConfig 1 } bwaVLUdpPortRangeNum OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of entries in the UDP Port Range Table" ::= { bwaVLUdpPortRangeConfig 2 } bwaVLUdpPortRangeTable OBJECT-TYPE SYNTAX SEQUENCE OF BwaVLUdpPortRangeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. A table of UDP port ranges use for prioritization. The user can define up to 64 ranges. An entry is empty if start is 65535 and end is 0" ::= { bwaVLUdpPortRangeConfig 3 } bwaVLUdpPortRangeEntry OBJECT-TYPE SYNTAX BwaVLUdpPortRangeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. A UDP Port Ranges Table entry." INDEX { bwaVLUdpPortRangeIdx } ::= { bwaVLUdpPortRangeTable 1 } BwaVLUdpPortRangeEntry ::= SEQUENCE { bwaVLUdpPortRangeStart INTEGER, bwaVLUdpPortRangeEnd INTEGER, bwaVLUdpPortRangeIdx INTEGER } bwaVLUdpPortRangeStart OBJECT-TYPE SYNTAX INTEGER(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Start port of an UDP Port Range" ::= { bwaVLUdpPortRangeEntry 1 } bwaVLUdpPortRangeEnd OBJECT-TYPE SYNTAX INTEGER(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. End port of an UDP Port Range" ::= { bwaVLUdpPortRangeEntry 2 } bwaVLUdpPortRangeIdx OBJECT-TYPE SYNTAX INTEGER(1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. UDP Port Range Entry's index " ::= { bwaVLUdpPortRangeEntry 3 } bwaVLUdpPortRangeAdd OBJECT-TYPE SYNTAX DisplayString (SIZE(0..250)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Add port range(s) to UDP Port Ranges Table. Get operation will return the empty string. A range is defined - or where is the Start Port of the range and is the End Port. If only is specified the range is -. The value of and are between 0..65535. The user can add several ranges using a comma to separate between ranges. Example: 10-256,99,987-900" ::= { bwaVLUdpPortRangeConfig 4 } bwaVLUdpPortRangeDelete OBJECT-TYPE SYNTAX DisplayString (SIZE(0..250)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Delete port range(s) from UDP Port Ranges Table. Get operation will return the empty string. A range is defined - or where is the Start Port of the range and is the End Port. If only is specified the range is -. The value of and are between 0..65535. The user can delete several ranges using a comma to separate between ranges. Example: 10-256,99,987-900" ::= { bwaVLUdpPortRangeConfig 5 } bwaVLUdpPortRangeDeleteAll OBJECT-TYPE SYNTAX INTEGER { deleteAll(1), cancelOperation(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Delete all entries form UDP Port Ranges Table. Get operation will return 1" ::= { bwaVLUdpPortRangeConfig 6 } bwaVLTcpPortRangeConfig OBJECT IDENTIFIER ::= {bwaVLTrafficPriUdpTcpPortRange 3} bwaVLTcpPortPriRTPRTCP OBJECT-TYPE SYNTAX INTEGER {rtpANDrtcp(1),rtpOnly(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. RTP/RTCP ports prioritization option for TCP packets. rtpANDrtcp(1): the possible RTP and RTCP packet with destination port in the defined port ranges will get HIGH priority rtpOnly(2): only possible RTP packet (packet with even destination port )" ::= { bwaVLTcpPortRangeConfig 1 } bwaVLTcpPortRangeNum OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of entries in the TCP Port Range Table" ::= { bwaVLTcpPortRangeConfig 2 } bwaVLTcpPortRangeTable OBJECT-TYPE SYNTAX SEQUENCE OF BwaVLTcpPortRangeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of TCP Port Ranges use for prioritization. The user can define up to 64 ranges. An entry is empty if start is 65535 and end is 0" ::= { bwaVLTcpPortRangeConfig 3 } bwaVLTcpPortRangeEntry OBJECT-TYPE SYNTAX BwaVLTcpPortRangeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to all units. A TCP Port Ranges Table entry." INDEX { bwaVLTcpPortRangeIdx } ::= { bwaVLTcpPortRangeTable 1 } BwaVLTcpPortRangeEntry ::= SEQUENCE { bwaVLTcpPortRangeStart INTEGER, bwaVLTcpPortRangeEnd INTEGER, bwaVLTcpPortRangeIdx INTEGER } bwaVLTcpPortRangeStart OBJECT-TYPE SYNTAX INTEGER(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Start port of a TCP Port Range" ::= { bwaVLTcpPortRangeEntry 1 } bwaVLTcpPortRangeEnd OBJECT-TYPE SYNTAX INTEGER(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. End port of a TCP Port Range" ::= { bwaVLTcpPortRangeEntry 2 } bwaVLTcpPortRangeIdx OBJECT-TYPE SYNTAX INTEGER(1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. TCP Port Range Entry's index" ::= { bwaVLTcpPortRangeEntry 3 } bwaVLTcpPortRangeAdd OBJECT-TYPE SYNTAX DisplayString (SIZE(0..250)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Add port range(s) to TCP Port Ranges Table. Get operation will return the empty string. A range is defined - or where is the Start Port of the range and is the End Port. If only is specified the range is -. The value of and are between 0..65535. The user can add several ranges using comma to separate between ranges. Example: 10-256,99,987-900" ::= { bwaVLTcpPortRangeConfig 4 } bwaVLTcpPortRangeDelete OBJECT-TYPE SYNTAX DisplayString (SIZE(0..250)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Delete port range(s) from TCP Port Ranges Table. Get operation will return the empty string. A range is defined - or where is the Start Port of the range and is the End Port. If only is specified the range is -. The value of and are between 0..65535. The user can delete several ranges using comma to separate between ranges. Example: 10-256,99,987-900" ::= { bwaVLTcpPortRangeConfig 5 } bwaVLTcpPortRangeDeleteAll OBJECT-TYPE SYNTAX INTEGER { deleteAll(1), cancelOperation(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Delete all entries form TCP Port Ranges Table Get operation will return 1" ::= { bwaVLTcpPortRangeConfig 6 } bwaVLWirelessLinkPrioritization OBJECT IDENTIFIER ::= {bwaVLTrafficPrioritization 4} bwaVLWirelessLinkPrioritizationOption OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2), na(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100. Enable/disable the traffic prioritization over the Wireless Link" ::= { bwaVLWirelessLinkPrioritization 1} bwaVLlowPriorityAIFS OBJECT-TYPE SYNTAX INTEGER (3..254) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100. Applicable only if the Wireless Link Prioritization Option is enabled. Define the AIFS (Arbitration Inter-frame Space) that will be used for transmitting Low Priority Traffic" ::= { bwaVLWirelessLinkPrioritization 2} bwaVLHWRetriesHighPriority OBJECT-TYPE SYNTAX INTEGER (0..14) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100. Applicable only if the Wireless Link Prioritization Option is enabled. Defines the Maximum number of HW Retries for a unicast data packet that has High Priority" ::= { bwaVLWirelessLinkPrioritization 3} bwaVLHWRetriesLowPriority OBJECT-TYPE SYNTAX INTEGER (0..14) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100. Applicable only if the Wireless Link Prioritization Option is enabled. Defines the Maximum number of HW Retries for a unicast data packet that has Low Priority" ::= { bwaVLWirelessLinkPrioritization 4} bwaVLAUBurstDurationHighPriority OBJECT-TYPE SYNTAX INTEGER (0..40) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100. Applicable only if the Wireless Link Prioritization Option is enabled. Defines the Maximum duration of burst that can be done by AU with High Priority packets. The time is given in 250 microseconds units" ::= { bwaVLWirelessLinkPrioritization 5} bwaVLAUBurstDurationLowPriority OBJECT-TYPE SYNTAX INTEGER (0..40) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100. Applicable only if the Wireless Link Prioritization Option is enabled. Defines the Maximum duration of burst that can be done by AU with Low Priority packets. The time is given in 250 microseconds units" ::= { bwaVLWirelessLinkPrioritization 6} bwaVLSUBurstDurationHighPriority OBJECT-TYPE SYNTAX INTEGER (0..40) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100. Applicable only if the Wireless Link Prioritization Option is enabled. Defines the Maximum duration of burst that can be done by SU/RB with High Priority packets. The parameter is configurable in AU and the SUs/RB will learn it form AU/BU. The time is given in 250 microseconds units" ::= { bwaVLWirelessLinkPrioritization 7} bwaVLSUBurstDurationLowPriority OBJECT-TYPE SYNTAX INTEGER (0..40) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100. Applicable only if the Wireless Link Prioritization Option is enabled. Defines the Maximum duration of burst that can be done by SU/RB with High Priority packets. The parameter is configurable in AU/BU and the SUs/RB will learn it from AU/BU. The time is given in 250 microseconds units" ::= { bwaVLWirelessLinkPrioritization 8} --DRAP BEGIN bwaVLDrap OBJECT IDENTIFIER ::= { bwaVLServiceParameters 11 } bwaVLDrapSupport OBJECT-TYPE SYNTAX INTEGER {disable(1), enable(2), na(255)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU. Not applicable to BWA PtP products. Disable/Enable the DRAP feature" ::= { bwaVLDrap 1 } bwaVLDrapUdpPort OBJECT-TYPE SYNTAX INTEGER (8000..8200) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU when DRAP support is enabled. Not applicable to BWA PtP products. The UDP port used for the DRAP server" ::= { bwaVLDrap 2 } bwaVLDrapMaxNumberOfVoiceCalls OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU when DRAP support is enabled. Not applicable to BWA PtP products. The maximum number of voice calls that can be supported by the AU" ::= { bwaVLDrap 3 } bwaVLDrapTTL OBJECT-TYPE SYNTAX INTEGER (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU when DRAP support is enabled. Not applicable to BWA PtP products. The maximum time between two allocation requests" ::= { bwaVLDrap 4 } bwaVLDrapNoOfActiveVoiceCalls OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU when DRAP support is enabled. Not applicable to BWA PtP products. The current total number of active voice calls." ::= { bwaVLDrap 5 } --DRAP END bwaVLLowPriorityTrafficMinimumPercent OBJECT-TYPE SYNTAX INTEGER (0..100) MAX-ACCESS read-write STATUS current DESCRIPTION "The minimum percent of the traffic rate that is allocated to the low priority traffic" ::= { bwaVLServiceParameters 12 } bwaVLSUPMirDownlink OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. The Maximum Information Rate (MIR) from AU to SUP. Range for set: 128 to 12,032 (Kbps). The actual value (Get) will be the entered value rounded to the nearest multiple of 128 (N*128)." ::= { bwaVLServiceParameters 13 } bwaVLMIRThresholdPercent OBJECT-TYPE SYNTAX INTEGER (0..100) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU only. MIR Threshold Percent" ::= { bwaVLServiceParameters 14 } -- User Filtering Params -- ===================== bwaVLUserFilterParams OBJECT IDENTIFIER ::= {bwaVLMib 8} bwaVLUserFilterOption OBJECT-TYPE SYNTAX INTEGER { disable (1), ipOnly (2), userDefinedAddrOnly (3), pPPoEOnly (4), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. Defines user-filtering options. disable: No filtering. iPOnly: Only IP protocol frames pass. userDefinedAddrOnly: Only ip frames to/from user defined IP addresses pass. pPPoE Only: Only PPPoE frames pass." ::= { bwaVLUserFilterParams 1 } bwaVLIpFilterTable OBJECT-TYPE SYNTAX SEQUENCE OF BwaVLIpFilterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to SU/RB only. An IP Filter Table of up to 8 user defined addresses, or address groups, to be used if the selected User Filtering option is userDefinedAddrOnly." ::= { bwaVLUserFilterParams 2 } bwaVLIpFilterEntry OBJECT-TYPE SYNTAX BwaVLIpFilterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to SU/RB only. An IP Filter Table entry." INDEX { bwaVLIpFilterIdx } ::= { bwaVLIpFilterTable 1 } BwaVLIpFilterEntry ::= SEQUENCE { bwaVLIpID IpAddress, bwaVLMaskID IpAddress, bwaVLIpFilterRange INTEGER, bwaVLIpFilterIdx INTEGER } bwaVLIpID OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. An IP address of an IP Filter Table entry." ::= { bwaVLIpFilterEntry 1 } bwaVLMaskID OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. An IP Mask of an IP Filter Table entry. Either a mask or a range, but not both can be used to define an address group. If the range is other than 0, than the mask is ignored and only the range value is used to define the address group." ::= { bwaVLIpFilterEntry 2 } bwaVLIpFilterRange OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. An addresses range for the IP Filter Table entry. The first address in the range is the IP address. O means that the range is not used. Either a mask or a range, but not both can be used to define an address group. If the range is other than 0, than the mask is ignored and only the range value is used to define the address group. Range: 0 to 255." ::= { bwaVLIpFilterEntry 3 } bwaVLIpFilterIdx OBJECT-TYPE SYNTAX INTEGER (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. A table index for the IP Filter Table entry." ::= { bwaVLIpFilterEntry 4 } bwaVLDeleteOneUserFilter OBJECT-TYPE SYNTAX INTEGER { deletefirstEntry (1), deletesecondEntry (2), deletethirdEntry (3), deletefourthEntry (4), deletefifthEntry (5), deletesixthEntry (6), deleteseventhEntry(7), deleteeighthEntry (8), cancelOperation (9), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. Deletes a single selected entry from the IP Filter Table." ::= { bwaVLUserFilterParams 3 } bwaVLDeleteAllUserFilters OBJECT-TYPE SYNTAX INTEGER { deleteAll (1), cancelOperation (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. Deletes all entries from the IP Filter Table." ::= { bwaVLUserFilterParams 4 } bwaVLDHCPUnicastOverrideFilter OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. Enables or disables the unicast DHCP messages, overriding the IP Filtering option." ::= { bwaVLUserFilterParams 5 } -- Security Params -- ================== bwaVLSecurityParameters OBJECT IDENTIFIER ::= {bwaVLMib 9} bwaVLAuthenticationAlgorithm OBJECT-TYPE SYNTAX INTEGER {openSystem(1) , sharedKey(2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Enables/disables the authentication encryption option. openSystem: Authentication messages are not encrypted. sharedKey : Authentication messages are encrypted " ::= { bwaVLSecurityParameters 1 } bwaVLSUDefaultKeyID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB only. The key to be used for encryption of authentication messages and/or data. Range: 1 to 4. " ::= { bwaVLSecurityParameters 2 } bwaVLDataEncryptionOption OBJECT-TYPE SYNTAX INTEGER {disable(1) , enable(2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Enables/disables the data encryption option. " ::= { bwaVLSecurityParameters 3 } bwaVLAUDefaultMulticastKeyID OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. The key to be used for encryption of multicasts and broadcasts." ::= { bwaVLSecurityParameters 4 } bwaVLSecurityMode OBJECT-TYPE SYNTAX INTEGER {wep(1) , aesOCB(2), fips197(3)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The fips197 option is applicable only to units with a license to use FIPS 197 algorithm. The encryption algorithm to be used for authentication messages and/or data encryption." ::= { bwaVLSecurityParameters 5 } bwaVLAuthenticationPromiscuousMode OBJECT-TYPE SYNTAX INTEGER {disable(1) , enable(2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. Enables/disable the promiscuous mode allowing authentication of and communication with all SUs/RB regardless of their security parameters." ::= { bwaVLSecurityParameters 6 } bwaVLKey1 OBJECT-TYPE SYNTAX DisplayString (SIZE(32)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Key number 1. Accessible only with SNMP Write Community String (administrator password). Valid values: 32 hexadecimal digits." ::= { bwaVLSecurityParameters 7 } bwaVLKey2 OBJECT-TYPE SYNTAX DisplayString (SIZE(32)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Key number 2. Accessible only with SNMP Write Community String (administrator password). Valid values: 32 hexadecimal digits." ::= { bwaVLSecurityParameters 8 } bwaVLKey3 OBJECT-TYPE SYNTAX DisplayString (SIZE(32)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Key number 3. Accessible only with SNMP Write Community String (administrator password). Valid values: 32 hexadecimal digits." ::= { bwaVLSecurityParameters 9 } bwaVLKey4 OBJECT-TYPE SYNTAX DisplayString (SIZE(32)) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Key number 4. Accessible only with SNMP Write Community String (administrator password). Valid values: 32 hexadecimal digits." ::= { bwaVLSecurityParameters 10 } bwaVLSecurityModeSupport OBJECT-TYPE SYNTAX INTEGER (0..7) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Returns types of encryption that are supported. 0 - no encryption 1 - WEP 2 - AES OCB 3 - WEP and AES OCB 4 - FIPS-197 5 - FIPS-197 and WEP 6 - FIPS-197 and AES OCB 7 - FIPS-197, AES OCB and WEP" ::= { bwaVLSecurityParameters 12 } -- Performance Params -- ================== bwaVLPerformanceParams OBJECT IDENTIFIER ::= {bwaVLMib 10} bwaVLRTSThreshold OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU and AU. Not applicable to BWA-PtP products. The minimum frame size that requires an RTS/CTS handshake. Range: For units bearing SW version 3.0 and above: 20 to 3400 bytes, for previous SW versions 20 to 1600 bytes. BWA-PtP products return 65535." ::= { bwaVLPerformanceParams 1 } bwaVLMinContentionWindow OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU and AU. For units bearing SW version 4.0 and above applicable to BWA PtP products, for previous SW versions not applicable to BWA PtP products. The initial value to be used by the contention window calculation algorithm. Value must be 0 or power of 2 minus 1 (7,15,31...). Range: 0 to 1023, excluding 1 and 3. BWA-PtP products with SW version below 4.0 return 65535." ::= { bwaVLPerformanceParams 3 } bwaVLMaxContentionWindow OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU and AU. For units bearing SW version 4.0 and above applicable to BWA PtP products, for previous SW versions not applicable to BWA PtP products. The maximum value to be used by the contention window calculation algorithm. Value must be power of 2 minus 1 (7,15,31...) Range: 7 to 1023." ::= { bwaVLPerformanceParams 4 } bwaVLMaximumModulationLevel OBJECT-TYPE SYNTAX INTEGER { level1 (1), level2 (2), level3 (3), level4 (4), level5 (5), level6 (6), level7 (7), level8 (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. If the Adaptive Modulation algorithm is enabled, it sets the Maximum Modulation Level to be used. If The Modulation algorithm is disabled, it sets the Fixed Modulation Level to be used. The range is 1 to 8. 8 is not applicable for units with HW revision A." ::= { bwaVLPerformanceParams 5 } bwaVLMulticastModulationLevel OBJECT-TYPE SYNTAX INTEGER { level1 (1), level2 (2), level3 (3), level4 (4), level5 (5), level6 (6), level7 (7), level8 (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. The modulation level for multicast and broadcast data frames. The range is 1 to 8. 8 is not applicable for units with HW revision A." ::= { bwaVLPerformanceParams 6 } bwaVLAvgSNRMemoryFactor OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. The weight of history in average SNR calculation. The higher is the value, the higher is the weight of history. Range: -1 (Disregard History) to 32." ::= { bwaVLPerformanceParams 7 } bwaVLHardwareRetries OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Not applicable if Wireless Link Prioritization is enabled. The maximum number of trials to transmit an unacknowledged frame in each Hardware Retrial phase. Range : 1 to 14." ::= { bwaVLPerformanceParams 8 } bwaVLAdaptiveModulationParams OBJECT IDENTIFIER ::= {bwaVLPerformanceParams 9} bwaVLAdaptiveModulationAlgorithmOption OBJECT-TYPE SYNTAX INTEGER { disable (1) , enable (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Enables/disables the adaptive modulation level decision mechanism." ::= { bwaVLAdaptiveModulationParams 1 } bwaVLSoftwareRetrySupport OBJECT-TYPE SYNTAX INTEGER { disable (1) , enable (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Read-only for units with version 2.0. Not applicable for units with SW version 3.0 and higher. The status of the Software Retry mechanism. Enabled when the Adaptive Modulation algorithm is enabled and the Burst Mode Option is disabled. Otherwise it is disabled." ::= { bwaVLAdaptiveModulationParams 2 } bwaVLNumOfSoftwareRetries OBJECT-TYPE SYNTAX INTEGER { na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Read-only for units with version 2.0. Not applicable for units with SW version 3.0 and higher. The maximum number of times to use the Software Retry mechanism when it is enabled." ::= { bwaVLAdaptiveModulationParams 3 } bwaVLMinIntervalBetweenAdaptiveModulationAlgorithmMessages OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable all units. The minimum interval between two consecutive AU/BU to SU/RB messages. Range: 1 to 3600 (Sec)." ::= { bwaVLAdaptiveModulationParams 4 } bwaVLAdaptiveModulationDecisionThresholds OBJECT-TYPE SYNTAX INTEGER { normal (1) , high (2), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Defines the setting of thresholds for the rate decision algorithm. high (2) should typically be used when the SNR is lower than 13dB." ::= { bwaVLAdaptiveModulationParams 5 } bwaVLBurstMode OBJECT IDENTIFIER ::= {bwaVLPerformanceParams 10} bwaVLBurstModeOption OBJECT-TYPE SYNTAX INTEGER { disable (1) , enable (2), blocked(3), na (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Applicable only if Burst Mode Option is supported by country specific parameters of the Sub Band. Not applicable if Wireless Link Prioritization is enabled. Enables/disable burst mode operation. In SU/RB with HW Revision B or lower blocked(3) value is returned when Security Mode is Wep , Data Encryption Option is Enabled and Burst option is Enabled. In AU/BU with HW Revision B or lower blocked(3) value is returned when Dfs Option is Enabled and Burst mode is enabled." ::= { bwaVLBurstMode 1 } bwaVLBurstInterval OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Not applicable if Wireless Link Prioritization is enabled. Burst mode interval in milliseconds. Range: 1 to the maximum value as defined in the country specific parameters of the Sub Band (milliseconds)." ::= { bwaVLBurstMode 2 } bwaVLConcatenationParameters OBJECT IDENTIFIER ::= {bwaVLPerformanceParams 11} bwaVLConcatenationOption OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2), na (255)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Defines the Concatenation option." ::= { bwaVLConcatenationParameters 1 } bwaVLConcatenationMaximumNumberOfFrames OBJECT-TYPE SYNTAX INTEGER (2..8) MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units with SW version 3.X . Not applicable for version 4.0 and higher. Defines the maximum numbers of frames that can be concatenated. Range:2 to 8 (frames)." ::= { bwaVLConcatenationParameters 2 } bwaVLConcatenationMaxFrameSize OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Defines the maximum size of a concatenated frame. Range: 256 to 2200 (bytes) for BWA PtP products BU/RB14 BU/RB28, or for AU/SU with HW revision A or B. 256 to 4032 (bytes) for AU/SU with HW Revision C or higher and BWA PtP products BU/RB100." ::= { bwaVLConcatenationParameters 3 } -- Site Survey Params -- ================== bwaVLSiteSurvey OBJECT IDENTIFIER ::= {bwaVLMib 11} bwaVLAverageReceiveSNR OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB only. The average Signal to Noise Ratio of received frames." ::= { bwaVLSiteSurvey 1 } -- Traffic Counters -- ================ bwaVLTrafficStatistics OBJECT IDENTIFIER ::= {bwaVLSiteSurvey 2} bwaVLResetTrafficCounters OBJECT-TYPE SYNTAX INTEGER { reset (1),cancel(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Resets the traffic counters." ::= { bwaVLTrafficStatistics 1 } bwaVLEthCounters OBJECT IDENTIFIER ::= {bwaVLTrafficStatistics 2} bwaVLWirelessLinkCounters OBJECT IDENTIFIER ::= {bwaVLTrafficStatistics 3} bwaVLWirelessLinkEvents OBJECT IDENTIFIER ::= {bwaVLTrafficStatistics 4} bwaVLPerModulationLevelCounters OBJECT IDENTIFIER ::= {bwaVLTrafficStatistics 5} bwaVLResetPerModulationLevelCounters OBJECT-TYPE SYNTAX INTEGER { resetCounters(1) , cancel (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to all units. Resets the per-Modulation Level counters ." ::= { bwaVLPerModulationLevelCounters 1 } bwaVLSUPerModulationLevelCountersTable OBJECT-TYPE SYNTAX SEQUENCE OF BwaVLSUPerModulationLevelCountersEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to SU/RB. Per Rate Counters table." ::= { bwaVLPerModulationLevelCounters 2 } bwaVLSUPerModulationLevelCountersEntry OBJECT-TYPE SYNTAX BwaVLSUPerModulationLevelCountersEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to SU/RB. An entry in the Per modulation Counters table." INDEX { bwaVLSUPerModulationLevelCountersTableIdx } ::= { bwaVLSUPerModulationLevelCountersTable 1 } BwaVLSUPerModulationLevelCountersEntry ::= SEQUENCE { bwaVLSUPerModulationLevelCountersTableIdx INTEGER, bwaVLSUPerModulationLevelCountersApplicableModLevel INTEGER, bwaVLSUPerModulationLevelCountersTxSuccess Counter32, bwaVLSUPerModulationLevelCountersTxFailed Counter32 } bwaVLSUPerModulationLevelCountersTableIdx OBJECT-TYPE SYNTAX INTEGER (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB. An index of an entry in the Per modulation level Counters table." ::= { bwaVLSUPerModulationLevelCountersEntry 1 } bwaVLSUPerModulationLevelCountersApplicableModLevel OBJECT-TYPE SYNTAX INTEGER { modLevel-1 (1), modLevel-2 (2), modLevel-3 (3), modLevel-4 (4), modLevel-5 (5), modLevel-6 (6), modLevel-7 (7), modLevel-8 (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB. The applicable modulation level of the entry in the Per modulation level Counters table. Modulation Level 8 is not applicable for units with HW revision A." ::= { bwaVLSUPerModulationLevelCountersEntry 2 } bwaVLSUPerModulationLevelCountersTxSuccess OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB. The total number of successfully transmitted unicasts at the applicable modulation level." ::= { bwaVLSUPerModulationLevelCountersEntry 3 } bwaVLSUPerModulationLevelCountersTxFailed OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB. The total number of dropped frames at the applicable Modulation Level." ::= { bwaVLSUPerModulationLevelCountersEntry 4 } bwaVLAverageModulationLevel OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB. The average modulation level for successful transmission (rounded to nearest integer) since last reset of the Per Modulation Level counters. Range: 1 to 8." ::= { bwaVLPerModulationLevelCounters 3 } bwaVLTotalRxFramesViaEthernet OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Total number of frames received via the Ethernet port." ::= { bwaVLEthCounters 1 } bwaVLTxWirelessToEthernet OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Total number of frames transmitted to the Ethernet port." ::= { bwaVLEthCounters 2 } bwaVLTxFramesToWireless OBJECT IDENTIFIER ::= {bwaVLWirelessLinkCounters 1} bwaVLAUBeaconsToWireless OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The number of beacons transmitted to the wireless media." ::= { bwaVLTxFramesToWireless 1 } -- bwaVLOtherMngFramesToWireless OBJECT-TYPE -- SYNTAX Counter32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "Applicable to AU and SU. -- The number of management frames transmitted to the wireless media. -- In AU, this count does not include Beacons." -- ::= { bwaVLTxFramesToWireless 2 } bwaVLDataAndOtherMngFramesToWireless OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The number of data and management frames transmitted to the wireless media. The count includes one count for each data frame transmitted successfully (excluding retransmissions)." ::= { bwaVLTxFramesToWireless 3 } bwaVLTotalTxFramesToWireless OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of frames transmitted to the wireless media. The count includes one count for each data frame that was transmitted successfully (excluding retransmissions), and also the number of transmitted control and management frames, including beacons." ::= { bwaVLTxFramesToWireless 4 } bwaVLTotalTransmittedUnicasts OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The total number of unicast frames successfully transmitted to the wireless media, excluding retransmissions." ::= { bwaVLTxFramesToWireless 5 } bwaVLTotalTransmittedConcatenatedFramesDouble OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all products. The total number of double concatenated frames successfully transmitted to the wireless media, excluding retransmissions." ::= { bwaVLTxFramesToWireless 6 } bwaVLTotalTransmittedConcatenatedFramesSingle OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all products. The total number of double concatenated frames successfully transmitted to the wireless media, excluding retransmissions." ::= { bwaVLTxFramesToWireless 7 } bwaVLTotalTransmittedConcatenatedFramesMore OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all products. The total number of concatenated frames with more then two frames successfully transmitted to the wireless media, excluding retransmissions." ::= { bwaVLTxFramesToWireless 8 } bwaVLTotalRxFramesFromWireless OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The total number of frames that were received from the wireless media. The count includes data and control and management frames, including beacons received from the AU/BU. The count does not include frames that were discarded internally, bad frames and duplicate frames." ::= { bwaVLWirelessLinkCounters 2 } bwaVLTotalRetransmittedFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The total number of retransmissions of data frames (counts all unsuccessful transmissions/retransmissions)." ::= { bwaVLWirelessLinkCounters 3 } bwaVLFramesDropped OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of dropped frames. The frames that were retransmitted to the extent of the maximum allowed number of retransmissions without being acknowledged.." ::= { bwaVLWirelessLinkCounters 4 } bwaVLDataFramesSubmittedToBridge OBJECT IDENTIFIER ::= {bwaVLWirelessLinkCounters 5} bwaVLFramesSubmittedViaHighQueue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Frames submitted to the internal bridge via the High priority queue. for transmission to the wireless media." ::= { bwaVLDataFramesSubmittedToBridge 1 } bwaVLFramesSubmittedViaMidQueue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Frames submitted to the internal bridge via the Mid priority queue for transmission to the wireless media." ::= { bwaVLDataFramesSubmittedToBridge 2 } bwaVLFramesSubmittedViaLowQueue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Frames submitted to the internal bridge via the Low priority queue for transmission to the wireless media." ::= { bwaVLDataFramesSubmittedToBridge 3 } bwaVLTotalNoOfDataFramesSubmitted OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The total number of data frames submitted to the internal bridge for transmission to the wireless media." ::= { bwaVLDataFramesSubmittedToBridge 4 } bwaVLTotalRecievedDataFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The total number of data frames received from the wireless media, including duplicate frames." ::= { bwaVLWirelessLinkCounters 6 } bwaVLRecievedBadFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of frames received from the wireless media with errors (CRC errors)." ::= { bwaVLWirelessLinkCounters 7 } bwaVLNoOfDuplicateFramesDiscarded OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of frames discarded due to receiving multiple copies." ::= { bwaVLWirelessLinkCounters 8 } bwaVLNoOfInternallyDiscardedMirCir OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of data frames received from the Ethernet port that were discarded by the MIR/CIR mechanism either to avoid exceeding the maximum allowed information rate, or when the wireless link conditions do not enable reaching the allowed rate." ::= { bwaVLWirelessLinkCounters 9 } bwaVLTotalRxConcatenatedFramesDouble OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The total number of double concatenated frames received from the wireless media, including duplicate frames." ::= { bwaVLWirelessLinkCounters 10 } bwaVLTotalRxConcatenatedFramesSingle OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The total number of data fast frames single concatenated frames received from the wireless media, including duplicate frames." ::= { bwaVLWirelessLinkCounters 11 } bwaVLTotalRxConcatenatedFramesMore OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The total number of data fast frames concatenated with more then two frames received from the wireless media, including duplicate frames." ::= { bwaVLWirelessLinkCounters 12 } -- bwaVLInternallyGeneratedFramesSubmittedToBridge OBJECT-TYPE -- SYNTAX Counter32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "Applicable to SU and AU. Read-only. -- The number of internally generated frames(wireless management and control frames) -- submitted to the bridge for transmission to the wireless media." -- ::= { bwaVLWirelessLinkCounters 10 } bwaVLTxEvents OBJECT IDENTIFIER ::= {bwaVLWirelessLinkEvents 1} bwaVLDroppedFrameEvents OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of frames that were dropped because they were retransmitted to the maximum allowed number of retransmissions without being acknowledged." ::= { bwaVLTxEvents 1 } bwaVLFramesDelayedDueToSwRetry OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Not applicable for units with SW Version 3.0 and higher. The number of frames that were delayed because the SW retry algorithm was activated on a previous frame designated for the same recipient." ::= { bwaVLTxEvents 2 } bwaVLUnderrunEvents OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of frames whose transmission was aborted because the rate of submitting frames for transmission exceeded the available transmission capability." ::= { bwaVLTxEvents 3 } bwaVLOthersTxEvents OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of Tx events due to problems other than those of the other Tx Events counters." ::= { bwaVLTxEvents 4 } bwaVLTotalTxEvents OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The total number of Tx special events." ::= { bwaVLTxEvents 5 } bwaVLRxEvents OBJECT IDENTIFIER ::= {bwaVLWirelessLinkEvents 2} bwaVLPhyErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units, only when DFS is enabled. The number of unidentified signals." ::= { bwaVLRxEvents 1 } bwaVLCRCErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of frames received from the wireless media containing CRC errors." ::= { bwaVLRxEvents 2 } bwaVLOverrunEvents OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of frames that were discarded because the receive rate exceeded the processing capability or the capacity of the Ethernet port." ::= { bwaVLRxEvents 3 } bwaVLRxDecryptEvents OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of frames that were not received properly due to a problem in the data decryption mechanism." ::= { bwaVLRxEvents 4 } bwaVLTotalRxEvents OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The total number of Rx special events." ::= { bwaVLRxEvents 5 } -- Associations Database -- bwaVLMacAddressDatabase OBJECT IDENTIFIER ::= {bwaVLSiteSurvey 5} bwaVLAUMacAddressDatabase OBJECT IDENTIFIER ::= {bwaVLMacAddressDatabase 1} bwaVLAUAdbResetAllModulationLevelCounters OBJECT-TYPE SYNTAX INTEGER { reset (1), cancel (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to AU/BU only. To reset all the counters for all SUs/RB in the MAC Address Database." ::= { bwaVLAUMacAddressDatabase 1 } bwaVLAUAdbTable OBJECT-TYPE SYNTAX SEQUENCE OF BwaVLAUAdbEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to AU/BU only. AU/BU MAC Address Database table." ::= { bwaVLAUMacAddressDatabase 2 } bwaVLAUAdbEntry OBJECT-TYPE SYNTAX BwaVLAUAdbEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to AU/BU only. An entry in the AU/BU MAC Address Database table." INDEX { bwaVLAdbIndex } ::= { bwaVLAUAdbTable 1 } BwaVLAUAdbEntry ::= SEQUENCE { bwaVLAdbIndex INTEGER, bwaVLAdbMacAddress MacAddress, bwaVLAdbStatus INTEGER, bwaVLAdbSwVersion DisplayString, bwaVLAdbSNR INTEGER, bwaVLAdbMaxModulationLevel INTEGER, bwaVLAdbTxFramesTotal Counter32, bwaVLAdbDroppedFramesTotal Counter32, bwaVLAdbTxSuccessModLevel1 Counter32, bwaVLAdbTxSuccessModLevel2 Counter32, bwaVLAdbTxSuccessModLevel3 Counter32, bwaVLAdbTxSuccessModLevel4 Counter32, bwaVLAdbTxSuccessModLevel5 Counter32, bwaVLAdbTxSuccessModLevel6 Counter32, bwaVLAdbTxSuccessModLevel7 Counter32, bwaVLAdbTxSuccessModLevel8 Counter32, bwaVLAdbTxFailedModLevel1 Counter32, bwaVLAdbTxFailedModLevel2 Counter32, bwaVLAdbTxFailedModLevel3 Counter32, bwaVLAdbTxFailedModLevel4 Counter32, bwaVLAdbTxFailedModLevel5 Counter32, bwaVLAdbTxFailedModLevel6 Counter32, bwaVLAdbTxFailedModLevel7 Counter32, bwaVLAdbTxFailedModLevel8 Counter32, bwaVLAdbCirTx INTEGER, bwaVLAdbMirTx INTEGER, bwaVLAdbCirRx INTEGER, bwaVLAdbMirRx INTEGER, bwaVLAdbCirMaxDelay INTEGER, bwaVLAdbDistance INTEGER, bwaVLAdbHwRevision INTEGER, bwaVLAdbCpldVer DisplayString, bwaVLAdbCountryCode INTEGER, bwaVLAdbBootVer DisplayString, bwaVLAdbAtpcOption INTEGER, bwaVLAdbAdapModOption INTEGER, bwaVLAdbBurstModeOption INTEGER, bwaVLAdbConcatenationOption INTEGER, bwaVLAdbSecurityMode INTEGER, bwaVLAdbAuthOption INTEGER, bwaVLAdbDataEncyptOption INTEGER, bwaVLAdbAge INTEGER, bwaVLAdbUnitName DisplayString } bwaVLAdbIndex OBJECT-TYPE SYNTAX INTEGER (1..512) MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The index of an entry in the AU/BU MAC Address Database table." ::= { bwaVLAUAdbEntry 1 } bwaVLAdbMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The MAC Address of an SU/RB entry in the MAC Address Database table." ::= { bwaVLAUAdbEntry 2 } bwaVLAdbStatus OBJECT-TYPE SYNTAX INTEGER { associated (1), authenticated (2), notAuthenticated (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The status of the relevant SU/RB." ::= { bwaVLAUAdbEntry 3 } bwaVLAdbSwVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The SW version of the relevant SU/RB." ::= { bwaVLAUAdbEntry 4 } bwaVLAdbSNR OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The average Signal to Noise Ratio in dB of frames received by the AU/BU from the relevant SU/RB." ::= { bwaVLAUAdbEntry 5 } bwaVLAdbMaxModulationLevel OBJECT-TYPE SYNTAX INTEGER { modLevel-1 (1), modLevel-2 (2), modLevel-3 (3), modLevel-4 (4), modLevel-5 (5), modLevel-6 (6), modLevel-7 (7), modLevel-8 (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The value configured in the relevant SU/RB for the Maximum Modulation Level parameter. Modulation Level 8 is not applicable for units with HW revision A." ::= { bwaVLAUAdbEntry 6 } bwaVLAdbTxFramesTotal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of unicast frames (excluding retransmissions) that were successfully transmitted to the SU/RB over the wireless link." ::= { bwaVLAUAdbEntry 7 } bwaVLAdbDroppedFramesTotal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of frames intended to the SU/RB that were dropped because they were retransmitted to the extent of the maximum allowed number of retransmissions without being acknowledged." ::= { bwaVLAUAdbEntry 8 } bwaVLAdbTxSuccessModLevel1 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of unicast frames (excluding retransmissions) that were successfully transmitted to the SU/RB over the wireless link using modulation level 1." ::= { bwaVLAUAdbEntry 9 } bwaVLAdbTxSuccessModLevel2 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of unicast frames (excluding retransmissions) that were successfully transmitted to the SU/RB over the wireless link using modulation level 2." ::= { bwaVLAUAdbEntry 10 } bwaVLAdbTxSuccessModLevel3 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of unicast frames (excluding retransmissions) that were successfully transmitted to the SU/BU over the wireless link using modulation level 3." ::= { bwaVLAUAdbEntry 11 } bwaVLAdbTxSuccessModLevel4 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of unicast frames (excluding retransmissions) that were successfully transmitted to the SU/RB over the wireless link using modulation level 4." ::= { bwaVLAUAdbEntry 12 } bwaVLAdbTxSuccessModLevel5 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of unicast frames (excluding retransmissions) that were successfully transmitted to the SU/RB over the wireless link using modulation level 5." ::= { bwaVLAUAdbEntry 13 } bwaVLAdbTxSuccessModLevel6 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of unicast frames (excluding retransmissions) that were successfully transmitted to the SU/BU over the wireless link using modulation level 6." ::= { bwaVLAUAdbEntry 14 } bwaVLAdbTxSuccessModLevel7 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of unicast frames (excluding retransmissions) that were successfully transmitted to the SU/RB over the wireless link using modulation level 7." ::= { bwaVLAUAdbEntry 15 } bwaVLAdbTxSuccessModLevel8 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of unicast frames (excluding retransmissions) that were successfully transmitted to the SU/RB over the wireless link using modulation level 8. Not applicable for units with HW revision A." ::= { bwaVLAUAdbEntry 16 } bwaVLAdbTxFailedModLevel1 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of failures to successfully transmit unicast frames intended to the SU/RB using modulation level 1." ::= { bwaVLAUAdbEntry 17 } bwaVLAdbTxFailedModLevel2 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of failures to successfully transmit unicast frames intended to the SU/RB using modulation level 2." ::= { bwaVLAUAdbEntry 18 } bwaVLAdbTxFailedModLevel3 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of failures to successfully transmit unicast frames intended to the SU/RB using modulation level 3." ::= { bwaVLAUAdbEntry 19 } bwaVLAdbTxFailedModLevel4 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of failures to successfully transmit unicast frames intended to the SU/RB using modulation level 4." ::= { bwaVLAUAdbEntry 20 } bwaVLAdbTxFailedModLevel5 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of failures to successfully transmit unicast frames intended to the SU/RB using modulation level 5." ::= { bwaVLAUAdbEntry 21 } bwaVLAdbTxFailedModLevel6 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of failures to successfully transmit unicast frames intended to the SU/RB using modulation level 6." ::= { bwaVLAUAdbEntry 22 } bwaVLAdbTxFailedModLevel7 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of failures to successfully transmit unicast frames intended to the SU/RB using modulation level 7." ::= { bwaVLAUAdbEntry 23 } bwaVLAdbTxFailedModLevel8 OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Counts the total number of failures to successfully transmit unicast frames intended to the SU/RB using modulation level 8. Not applicable for units with HW revision A." ::= { bwaVLAUAdbEntry 24 } bwaVLAdbCirTx OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU Only. Not applicable to BWA-PtP products. Read-only. The value configured in the relevant SU for the CIR: SU to AU parameter." ::= { bwaVLAUAdbEntry 25 } bwaVLAdbMirTx OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The value configured in the relevant SU/RB for the MIR: SU/RB to AU/BU parameter." ::= { bwaVLAUAdbEntry 26 } bwaVLAdbCirRx OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU Only. Not applicable to BWA-PtP products. The value configured in the relevant SU for the CIR: AU to SU parameter." ::= { bwaVLAUAdbEntry 27 } bwaVLAdbMirRx OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The value configured in the relevant SU/RB for the MIR: AU/BU to SU/RB parameter." ::= { bwaVLAUAdbEntry 28 } bwaVLAdbCirMaxDelay OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU Only. Not applicable to BWA-PtP products. The value configured in the relevant SU for the CIR Maximum Delay parameter." ::= { bwaVLAUAdbEntry 29 } bwaVLAdbDistance OBJECT-TYPE SYNTAX INTEGER {below-2-Km(1)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU Only. The distance between the SU/RB and the AU/BU (In Kilometers)." ::= { bwaVLAUAdbEntry 30 } bwaVLAdbHwRevision OBJECT-TYPE SYNTAX INTEGER {hwRevisionA(1), hwRevisionB(2), hwRevisionC(3), hwRevisionD(4), hwRevisionE(5), na(255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU Only. The SU/RB HW Revision." ::= { bwaVLAUAdbEntry 31 } bwaVLAdbCpldVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU Only. The SU/RB CPLD Version." ::= { bwaVLAUAdbEntry 32 } bwaVLAdbCountryCode OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU Only. The SU/RB supported country code." ::= { bwaVLAUAdbEntry 33 } bwaVLAdbBootVer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU Only. The SU/RB Boot Version." ::= { bwaVLAUAdbEntry 34 } bwaVLAdbAtpcOption OBJECT-TYPE SYNTAX INTEGER {disable (1), enable (2), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU Only. The SU/RB ATPC option configuration." ::= { bwaVLAUAdbEntry 35 } bwaVLAdbAdapModOption OBJECT-TYPE SYNTAX INTEGER {disable (1), enable (2), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU Only. The SU/RB adaptive modulation option configuration." ::= { bwaVLAUAdbEntry 36 } bwaVLAdbBurstModeOption OBJECT-TYPE SYNTAX INTEGER {disable (1), enable (2), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU Only. The SU/RB burst mode option configuration." ::= { bwaVLAUAdbEntry 37 } bwaVLAdbConcatenationOption OBJECT-TYPE SYNTAX INTEGER {disable (1), enable (2), na(255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU Only. The SU/RB concatenation option configuration." ::= { bwaVLAUAdbEntry 39 } bwaVLAdbSecurityMode OBJECT-TYPE SYNTAX INTEGER {wep(1), aes(2), fips197(3), na(255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU Only. The SU/RB security mode configuration." ::= { bwaVLAUAdbEntry 41 } bwaVLAdbAuthOption OBJECT-TYPE SYNTAX INTEGER {openSystem (1), sharedKey (2), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU Only. The SU/RB authentication algorithm configuration." ::= { bwaVLAUAdbEntry 42 } bwaVLAdbDataEncyptOption OBJECT-TYPE SYNTAX INTEGER {disable (1), enable (2), na (255)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU Only. The SU/RB data encryption option configuration." ::= { bwaVLAUAdbEntry 43 } bwaVLAdbAge OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The time since any packet was received from the relevant SU/RB." ::= { bwaVLAUAdbEntry 44 } bwaVLAdbUnitName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The unit name of the relevant SU/RB." ::= { bwaVLAUAdbEntry 45 } bwaVLUpLinkQualityIndicator OBJECT IDENTIFIER ::= { bwaVLSiteSurvey 6} bwaVLMeasureUpLinkQualityIndicator OBJECT-TYPE SYNTAX INTEGER { start (1) , cancel (2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Applicable to SU/RB. Starts calculation of LQI. The calculation will be for a period of 10 seconds." ::= { bwaVLUpLinkQualityIndicator 1 } bwaVLReadUpLinkQualityIndicator OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB. The results of the last LQI calculation. Range: 1 to 8." ::= { bwaVLUpLinkQualityIndicator 2 } bwaVLUpLinkQualityIndicatorStatus OBJECT-TYPE SYNTAX INTEGER {fullTest(1) , limitedTest(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to SU/RB Only. Indicates the test conditions. fullTest means that there are no limitations on the range of available modulation levels, and that all modulation levels from 1 to 8 can be used. limitedTest indicates that the results may not indicate the true quality since the available range is limited - by HW (HW Revision A), or by the applicable parameters in the country code, or by the configurable Maximum Modulation Level parameter." ::= { bwaVLUpLinkQualityIndicator 3 } -- AC pinpoint table end bwaVLMacPinpoint OBJECT IDENTIFIER ::= {bwaVLSiteSurvey 7} bwaVLMacPinpointTable OBJECT-TYPE SYNTAX SEQUENCE OF BwaVLMacPinpointEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to AU/BU only. A table that contains information about wireless device used by a certain Ethernet station in order to connect to the wireless network" ::= { bwaVLMacPinpoint 1 } bwaVLMacPinpointEntry OBJECT-TYPE SYNTAX BwaVLMacPinpointEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Applicable to AU/BU only. An entry in the MAC Pinpoint Table. Each entry contains an Ethernet station MAC address and the MAC address of the wireless device used to connect it to the wireless network" INDEX { mptEthernetStationMACAddress } ::= { bwaVLMacPinpointTable 1 } BwaVLMacPinpointEntry ::= SEQUENCE { mptEthernetStationMACAddress MacAddress, mptUnitMACAddress MacAddress } mptEthernetStationMACAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The MAC address of the Ethernet station. It is used as an index in the MAC Pinpoint Table." ::= { bwaVLMacPinpointEntry 1 } mptUnitMACAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. The MAC address of the wireless device used by the station with the MAC Address from the index in order to access the wireless network." ::= { bwaVLMacPinpointEntry 2 } -- AC pinpoint table end -- GATEWAY TABLE BEGIN bwaVLDrapGatewaysTable OBJECT-TYPE SYNTAX SEQUENCE OF BwaVLDrapGatewayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table provides information about Gateways supporting DRAP that are registered at the AU" ::= { bwaVLSiteSurvey 8 } bwaVLDrapGatewayEntry OBJECT-TYPE SYNTAX BwaVLDrapGatewayEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A Drap Gateway Entry." INDEX { bwaVLDrapGatewayIndex } ::= { bwaVLDrapGatewaysTable 1 } BwaVLDrapGatewayEntry ::= SEQUENCE { bwaVLDrapGatewayIndex INTEGER, bwaVLDrapGatewayIP IpAddress, bwaVLDrapGatewayType INTEGER, bwaVLDrapGatewayNoOfActiveVoiceCalls INTEGER } bwaVLDrapGatewayIndex OBJECT-TYPE SYNTAX INTEGER (1..512) MAX-ACCESS read-only STATUS current DESCRIPTION "Gateway Entry's Index" ::= { bwaVLDrapGatewayEntry 1 } bwaVLDrapGatewayIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address of the Gateway" ::= { bwaVLDrapGatewayEntry 2 } bwaVLDrapGatewayType OBJECT-TYPE SYNTAX INTEGER { vgDataVoice (4), vgData1Voice1 (5), vgData4Voice2 (6), vgDataVoice2(7), ngData4Wireless (11), vgUnknown(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Gateway type" ::= { bwaVLDrapGatewayEntry 3 } bwaVLDrapGatewayNoOfActiveVoiceCalls OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The current number of active voice calls handled by the Gateway" ::= { bwaVLDrapGatewayEntry 4 } -- GATEWAY TABLE END -- **************************************************************************************** -- TRAP defenitions: -- **************************************************************************************** bwaVLTraps OBJECT IDENTIFIER ::= { bwaVLMib 14 } bwaVLTrapSUMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. SU/RB MAC Address." ::= { bwaVLTraps 1 } --bwaVLTrapSNRQuality OBJECT-TYPE -- SYNTAX INTEGER -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "Applicable to SU only. -- SNR of received signal." -- ::= { bwaVLTraps 2 } bwaVLTrapText OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Textual string for future use." ::= { bwaVLTraps 3 } bwaVLTrapToggle OBJECT-TYPE SYNTAX INTEGER{ on (1), off (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. An On/Off toggle status." ::= { bwaVLTraps 4 } bwaVLTrapParameterChanged OBJECT-TYPE SYNTAX INTEGER{ cirOrMir (1), ipFilter (2), vlan (4)} MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. A modification to one of the parameters related to CIR/MIR, IP Filtering or VLAN." ::= { bwaVLTraps 5 } bwaVLTrapAccessRights OBJECT-TYPE SYNTAX INTEGER{ notLoggedIn (1), readOnly (2), installer (3), administrator (4), factory (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The access rights used for login." ::= { bwaVLTraps 6 } bwaVLTrapLog OBJECT-TYPE SYNTAX INTEGER{ telnetLogin (3), telnetLogout (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. Login or logout to the Monitor program via Telnet." ::= { bwaVLTraps 7 } bwaVLTrapTelnetUserIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The IP address of a Telnet user." ::= { bwaVLTraps 8 } bwaVLTrapRTx OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU only. Retransmissions as a percentage of total transmissions." ::= { bwaVLTraps 9 } bwaVLTrapFtpOrTftpStatus OBJECT-TYPE SYNTAX INTEGER{ successful (1), failed (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The status of the last FTP/TFTP loading procedure." ::= { bwaVLTraps 10 } bwaVLDFSMoveFreq OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU with HW revision B and lower (for units with HW revision C and higher replaced by bwaVLTrapDFSMoveFreq New to support a resolution of 0.5 MHz). The new frequency in MHz after detecting radar on a previous channel." ::= { bwaVLTraps 11 } bwaVLDFSMoveFreqNew OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AU/BU. The new frequency in MHz after detecting radar on a previous channel. (Replaces bwaVLDFSMoveFreq to support a resolution of 0.5 MHz for units with HW revision C and higher)." ::= { bwaVLTraps 12 } bwaVLEthBroadcastThresholdExceeded OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to all units. The number of packets that are dropped by the ethernet broadcast/multicast limiter." ::= { bwaVLTraps 13 } bwaVLTrapSubscriberType OBJECT-TYPE SYNTAX INTEGER{ unknownSubscriberType(0), su-3(3) , su-6(6) , rb-14(14), su-24(24), rb-28(28), su-54(54), rb-100(100) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to AUS only. The type of subscriber that was rejected by AUS" ::= { bwaVLTraps 14 } bwaVLTrapMACAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to BU/RB only. The MAC address of the BWA PtP unit whose type has been changed" ::= { bwaVLTraps 15 } bwaVLNewUnitTypeTrap OBJECT-TYPE SYNTAX INTEGER { bu(1), rb(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Applicable to BU/RB only. The new type of the BWA PtP unit." ::= { bwaVLTraps 16 } bwaVLTrapSWVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The SW version of the SU that tries to associate with a station that has Wireless Link Prioritization Enabled" ::= { bwaVLTraps 17 } -- -- Private Traps for BWA-PtMP -- bwaVLSUassociatedAUTRAP NOTIFICATION-TYPE OBJECTS { bwaVLTrapSUMacAddr -- SU MAC address } STATUS current DESCRIPTION "An AU/BU trap indicating a new association with an SU/RB." ::= { bwaVLProducts 2 } bwaVLAUdisassociatedTRAP NOTIFICATION-TYPE OBJECTS { bwaVLTrapSUMacAddr --Unit MAC address } STATUS current DESCRIPTION "An AU/BU trap indicating that an SU/RB has been disassociated from the AU. The AU/BU decides that an SU/RB has been disassociated from it and remove it from the ADB after receiving from another AU/BU a SNAP frame with the SU/RB MAC address. The SNAP frame indicating a network topology change where the SU/RB has associated with another AU/BU will be received if both AUs/BUs are connected to the same Ethernet backbone." ::= { bwaVLProducts 3 } bwaVLAUagingTRAP NOTIFICATION-TYPE OBJECTS { bwaVLTrapSUMacAddr -- Unit MAC address } STATUS current DESCRIPTION "An AU/BU trap indicating that the unit association was aged out and removed from the Association database following its failure to acknowledge a specified number of consecutive frames." ::= { bwaVLProducts 4 } bwaVLSUassociatedTRAP NOTIFICATION-TYPE OBJECTS { -- bwaVLLastAUMacAddress, Old AU mac address bwaVLAssociatedAU -- New AU mac address -- bwaVLTrapLastSNRQuality, Average SNR with old AU } STATUS current DESCRIPTION "An SU/RB trap indicating association with an AU/BU. In addition to the MAC address information of the AU/BU, the trap also includes information on the average SNR of frames received from the AU/BU." ::= { bwaVLProducts 6 } bwaVLAUwirelessQualityTRAP NOTIFICATION-TYPE OBJECTS { bwaVLTrapToggle, bwaVLTrapRTx } STATUS current DESCRIPTION "An AU/BU trap, indicating that the quality of the wireless link (retransmissions rate) has changed and dropped below (Off) or increased above (On) a threshold , defined by the *bwaVLWirelessTrapThreshold. The threshold for AU/BU is a percentage of retransmissions." ::= { bwaVLProducts 20 } bwaVLPowerUpFromReset NOTIFICATION-TYPE OBJECTS { bwaVLUnitMacAddress -- Unit MAC address } STATUS current DESCRIPTION "An AU/BU trap indicating power up after Reset." ::= { bwaVLProducts 101 } bwaVLTelnetStatusTRAP NOTIFICATION-TYPE OBJECTS { bwaVLTrapLog, bwaVLTrapAccessRights, bwaVLTrapTelnetUserIpAddress } STATUS current DESCRIPTION "Applicable to all units. A trap indicating that a log-in or log-out has been performed via Telnet. Includes the log-in access right and the IP address of the PC performing Telnet." ::= { bwaVLProducts 102 } bwaVLParameterChangedTRAP NOTIFICATION-TYPE OBJECTS { bwaVLTrapParameterChanged } STATUS current DESCRIPTION "Applicable to all units. A trap indicating a change in a CIR/MIR, IP Filter or VLAN parameter." ::= { bwaVLProducts 103 } bwaVLLoadingStatusTRAP NOTIFICATION-TYPE OBJECTS { bwaVLTrapFtpOrTftpStatus, bwaVLUnitMacAddress } STATUS current DESCRIPTION "Applicable to all units. A trap indicating that last FTP/TFTP loading process has been finished successfully or failed. " ::= { bwaVLProducts 104 } bwaVLPromiscuousModeTRAP NOTIFICATION-TYPE OBJECTS { bwaVLTrapToggle, bwaVLUnitMacAddress } STATUS current DESCRIPTION "An AU/BU trap, indicating that the AU/BU In (On) Promiscuous Mode or out (Off) Promiscuous Mode." ::= { bwaVLProducts 105 } bwaVLDFSRadarDetecetedTRAP NOTIFICATION-TYPE STATUS current DESCRIPTION "DFS: Applicable to AU/BU only. A trap indicating that a radar was detected. " ::= { bwaVLProducts 106 } bwaVLDFSFrequcnyTRAP NOTIFICATION-TYPE OBJECTS { bwaVLDFSMoveFreq, bwaVLDFSMoveFreqNew } STATUS current DESCRIPTION "Applicable to AU/BU only. A trap indicating that the unit moved to a new frequency. " ::= { bwaVLProducts 107 } bwaVLDFSNoFreeChannelsExistsTRAP NOTIFICATION-TYPE STATUS current DESCRIPTION "Applicable to AU/BU only. A trap indicating that a radar was detected and there is no free channel. " ::= { bwaVLProducts 108 } bwaVLEthBroadcastMulticatLimiterTRAP NOTIFICATION-TYPE OBJECTS { bwaVLEthBroadcastThresholdExceeded } STATUS current DESCRIPTION "Applicable to all units. The trap is send if the ethernet broadcast filter threshold is exceeded and it contains the number of dropped packets." ::= { bwaVLProducts 109 } bwaVLAUSUnsupportedSubscriberTypeTRAP NOTIFICATION-TYPE OBJECTS { bwaVLTrapSUMacAddr, bwaVLTrapSubscriberType } STATUS current DESCRIPTION "Applicable to AUS only. This trap is generated when a subscriber with unsupported type tries to associate to AUS. The AUS supports only SU-3 and SU-6. The first variable of the trap is the subscriber MAC Address. The second variable is the type of subscriber" ::= { bwaVLProducts 110 } bwaVLUnitTypeChangedTRAP NOTIFICATION-TYPE OBJECTS { bwaVLTrapMACAddress, bwaVLNewUnitTypeTrap } STATUS current DESCRIPTION "Applicable to BU/RB only. This trap is generated when the user change the type of the BWA PtP unit. The RB can be converted in BU or vice versa. The first variable of the trap is the unit MAC Address. The second variable is the new type of the unit" ::= { bwaVLProducts 111 } bwaVLWLPrioritizationNotSupportedBySUTRAP NOTIFICATION-TYPE OBJECTS { bwaVLTrapSUMacAddr, bwaVLTrapSWVersion } STATUS current DESCRIPTION "Applicable to AU/BU only. This trap is generated when an SU/RB with a SW version below 4.0 that does not support Wireless Link Prioritization is associated with an AU/BU with thw Wireless Link Prioritization Option enabled. The first variable of the trap is the SU/RB MAC Address. The second variable is the SW version of the SU/RB" ::= { bwaVLProducts 112 } END