ARRIS-D5-SLOT-EXT-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, Counter32, Gauge32, IpAddress FROM SNMPv2-SMI TEXTUAL-CONVENTION, TruthValue, RowStatus, DisplayString, TimeStamp, DateAndTime FROM SNMPv2-TC OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF ifIndex, InterfaceIndex, InterfaceIndexOrZero FROM IF-MIB arrisD5UEQam FROM ARRIS-MIB; d5SlotExtMIB MODULE-IDENTITY LAST-UPDATED "200906100000Z" ORGANIZATION "Arris Group, Inc" CONTACT-INFO " Network Management Postal: Arris Group 3871 Lakefield Drive Suwanee, GA 30324 Tel: 678 473 8500" DESCRIPTION "This MIB manages the slot assignments on the Arris D5 DMTS." ::= { arrisD5UEQam 18 } d5SlotObjects OBJECT IDENTIFIER ::= { d5SlotExtMIB 1 } WAN7 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The wan card in slot 7." SYNTAX Unsigned32 (7) WAN8 ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The wan card in slot 8." SYNTAX Unsigned32 (8) WanValue ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Wan card selection for slot assignment." SYNTAX Unsigned32 (WAN7 | WAN8) -- Slot Assignment -- Provides mechanisms to assign slots to wan cards slotAssignmentTable OBJECT-TYPE SYNTAX SEQUENCE OF SlotAssignmentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A conceptual table for slot assignments." ::= { d5SlotObjects 1 } slotAssignmentEntry OBJECT-TYPE SYNTAX SlotAssignmentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A conceptual row entry of this table." INDEX { ifIndex } ::= { slotAssignmentTable 1 } SlotAssignmentEntry ::= SEQUENCE { dualWanEnable INTEGER, slot1Assignment WanValue, slot2Assignment WanValue, slot3Assignment WanValue, slot4Assignment WanValue, slot5Assignment WanValue, slot6Assignment WanValue } dualWanEnable OBJECT-TYPE SYNTAX INTEGER { dualWanDisabled(0), dualWanEnabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable or disable dual wan operation." DEFVAL { FALSE } ::= { slotAssignmentEntry 1 } slot1Assignment OBJECT-TYPE SYNTAX WanValue MAX-ACCESS read-write STATUS current DESCRIPTION "Assign the slot to the specified wan card." DEFVAL { WAN7 } ::= { slotAssignmentEntry 2 } slot2Assignment OBJECT-TYPE SYNTAX WanValue MAX-ACCESS read-write STATUS current DESCRIPTION "Assign the slot to the specified wan card." DEFVAL { WAN7 } ::= { slotAssignmentEntry 3 } slot3Assignment OBJECT-TYPE SYNTAX WanValue MAX-ACCESS read-write STATUS current DESCRIPTION "Assign the slot to the specified wan card." DEFVAL { WAN7 } ::= { slotAssignmentEntry 4 } slot4Assignment OBJECT-TYPE SYNTAX WanValue MAX-ACCESS read-write STATUS current DESCRIPTION "Assign the slot to the specified wan card." DEFVAL { WAN7 } ::= { slotAssignmentEntry 5 } slot5Assignment OBJECT-TYPE SYNTAX WanValue MAX-ACCESS read-write STATUS current DESCRIPTION "Assign the slot to the specified wan card." DEFVAL { WAN7 } ::= { slotAssignmentEntry 6 } slot6Assignment OBJECT-TYPE SYNTAX WanValue MAX-ACCESS read-write STATUS current DESCRIPTION "Assign the slot to the specified wan card." DEFVAL { WAN7 } ::= { slotAssignmentEntry 7 } -- -- -- identifyWan OBJECT-TYPE SYNTAX INTEGER ( 0..16 ) MAX-ACCESS read-only STATUS current DESCRIPTION "Identify the WAN slot in a dual wan configuration." ::= { d5SlotObjects 2 } END